6043239 [SICK]
TEMPERATURE SENSORS;型号: | 6043239 |
厂家: | SICK AG |
描述: | TEMPERATURE SENSORS |
文件: | 总5页 (文件大小:277K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
TCT-1AATE1006MZ
TCT
TEMPERATURE SENSORS
TCT-1AATE1006MZ | TCT
TEMPERATURE SENSORS
Ordering information
A
B
C
D
E
F
Type
TCT-1AATE1006MZ
Part no.
6043238
Other models and accessories www.sick.com/TCT
Illustration may differ
Detailed technical data
Features
–50 °C +150 °C
Pt100
Measuring range
Sensor element
4 mA ... 20 mA, 2-wire (RA ≤ (L+ – 9 V) / 0.023 A [Ohm])
Analog signal output and ohmic load RA
H
I
Performance
Class A according to IEC 60751
≤ ± 1,0 % of span
Accuracy of sensor element
Transmitter accuracy
Transmitter linearity
Response time
≤ 0.1 % of span
Response time t50: ≤ 2.8 s 1)
t90 ≤ 9,1 s 1)
J
K
L
1)
Depending on sensor configuration, according to IEC 60751.
Mechanics/electronics
Thermowell G ½ B
Process connection
Insertion length/diameter of probe
Wetted parts
100 mm / 6 mm
Stainless steel 1.4571
Max. 220 bar
M
N
O
P
Q
R
S
T
Pressure resistance
Housing material
Stainless steel 1.4571
Round connector M12 x 1, 4-pin, IP 67 1)
0.3 mA ... 1 mA
Electrical connection
Measuring current
Supply voltage
10 V DC ... 36 V DC
Ca. 30 mA
Maximum current consumption
Electrical safety
Protection class III
RoHS certificate
Weight
Protection class: III, insulation voltage: 500 V, reverse polarity protection: L+ to M
✔
✔
Ca. 145 g (depending on configuration)
< 10 ms
Initialization time
1)
IP enclosure rating as per IEC 60529. The enclosure rating classes specified only apply while the device is connected with male cable connectors of the correspond-
ing enclosure rating.
2
FLUID SENSORS | SICK
Online data sheet | 2017-02-23 11:18:08
Subject to change without notice
TCT-1AATE1006MZ | TCT
TEMPERATURE SENSORS
Ambient data
–40 °C ... +85 °C
–40 °C ... +85 °C
500 g
Ambient temperature
Storage and transport temperature
Shock resistance according to IEC 60751
3 g
Vibration resistance according to
IEC 60751
Classifications
27200208
27200208
27200208
27200208
27200208
27200208
27200208
27200208
EC001446
EC001446
41112211
ECl@ss 5.0
ECl@ss 5.1.4
ECl@ss 6.0
ECl@ss 6.2
ECl@ss 7.0
ECl@ss 8.0
ECl@ss 8.1
ECl@ss 9.0
ETIM 5.0
ETIM 6.0
UNSPSC 16.0901
Dimensional drawing (Dimensions in mm (inch))
Housing, without process connection
With circular connector M12x1
With L-connector (DIN EN 175301-803 A)
47
(1.85)
M12x1
27
1.06)
27
1.06)
(
(
D
D
2017-02-23 11:18:08 | Online data sheet
Subject to change without notice
FLUID SENSORS | SICK
3
TCT-1AATE1006MZ | TCT
TEMPERATURE SENSORS
Process connections, cylindrical threads
A
B
C
D
E
F
Thread, up to 150 °C
Thread, up to 250 °C
Compression fitting
Threaded thermowell
19
(0.75)
14
(0.55)
27
(1.06)
27
(1.06)
D
D
D
D
H
I
Connection type
Plug M12 x 1, output signal 4 mA ... 20 mA
L+/ Q
A
+
-
J
4
1
3
2
K
L
-
M
+
M
N
O
P
Q
R
S
T
4
FLUID SENSORS | SICK
Online data sheet | 2017-02-23 11:18:08
Subject to change without notice
相关型号:
©2020 ICPDF网 联系我们和版权申明