6050064 [SICK]
SWITCHING AUTOMATION LIGHT GRIDS;型号: | 6050064 |
厂家: | SICK AG |
描述: | SWITCHING AUTOMATION LIGHT GRIDS 开关 |
文件: | 总7页 (文件大小:364K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
FLG2-20012021
FLG
SWITCHING AUTOMATION LIGHT GRIDS
FLG2-20012021 | FLG
SWITCHING AUTOMATION LIGHT GRIDS
Ordering information
A
B
C
D
E
F
Type
Part no.
FLG2-20012021
6050064
Other models and accessories www.sick.de/FLG
Illustration may differ
Detailed technical data
Features
Open
Version
Sender/receiver
Technology
H
I
Dynamic: 2 mm 1)
Static: 6 mm
Minimum detectable object (MDO)
2 mm
Beam separation
Output function
Light/dark switching adjustable by means of rotary switch
1)
J
2 mm MDO in limited detection area.
Performance
120 mm x 200 mm 1)
< 0.1 ms
K
L
Detection area (W x H)
Response time
1)
2 mm MDO in limited detection area.
Interfaces
M
N
O
P
Q
R
S
T
PNP/NPN (Q and /Q)
Switching output
M12, 4-pin male connector
Connection type
Mechanics/electronics
Wave length
880 nm
DC 18 V ... 30 V 1)
< 10 %
Supply voltage Vs
Ripple
≤ 100 mA
Output current Imax.
Off delay
0 s ... 5 s 2)
0.3 s
Initialization time
Dimensions (W x H x D)
Housing material
182 mm x 230 mm x 25 mm
Aluminum, painted
1)
Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
Adjustable.
2)
2
AUTOMATION LIGHT GRIDS | SICK
Online data sheet | 2016-03-09 17:40:10
Subject to change without notice
FLG2-20012021 | FLG
SWITCHING AUTOMATION LIGHT GRIDS
LED
Indication
IP 65
Enclosure rating
Circuit protection
UV connections, reverse polarity protected, Output Q short-circuit protected, Interference pulse
suppression
≥ 1.12 kg
Weight
≤ 5,000 Hz
Switching frequency
1)
Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
Adjustable.
2)
Ambient data
III
Protection class
EMC
EN 60947-5-2
Operation: 0 °C ... +60 °C 1)
Storage: –20 °C ... +80 °C
Ambient temperature
Sunlight: 10,000 lx
EN 60068-2-6
Ambient light immunity
Vibration resistance
Shock load
EN 60068-2-27
1)
In static mode: constant temperature around teaching point will be assumed.
Dimensional drawing (Dimensions in mm (inch))
FLGx-200xxx2x
17.5
(0.69)
10.2
(0.40)
5.5
(0.22)
.20)
5 (0
4 x Ø
a
a1
FLGx-200120xx
FLGx-200180xx
182 (7.17)
242 (9.53)
120 (4.72)
180 (7.09)
250 (9.84)
S
R
S
T
FLGx-200250xx 312 (12.28)
25
(0.98)
37
(1.46)
25
(0.98)
a1
a
2016-03-09 17:40:10 | Online data sheet
Subject to change without notice
AUTOMATION LIGHT GRIDS | SICK
3
FLG2-20012021 | FLG
SWITCHING AUTOMATION LIGHT GRIDS
Adjustments
A
B
C
D
E
F
Indication LED
N
C
C
N
N
O
O
N
1
2
① Yellow LED: status output
② Red LED: error or button lock active (blinking)
Connection type and diagram
M12, 4-pin male connector
H
I
1
2
3
4
brn
wht
blu
blk
L+
nc
M
QPNP/NPN /Q¯PNP/NPN
J
K
L
M
N
O
P
Q
R
S
T
4
AUTOMATION LIGHT GRIDS | SICK
Online data sheet | 2016-03-09 17:40:10
Subject to change without notice
FLG2-20012021 | FLG
SWITCHING AUTOMATION LIGHT GRIDS
Concept of operation
Setting key lock
S
Locking:
After the last setting, the
frame waits 15 minutes then
locks the potentiometer.
When the potentiometers are
locked, the red LED flashes
every time you turn any button.
T
N
C
C
N
1
N
O
O
N
Unlocking:
1 To unlock the potentiometers,
turn the mode button on the
“Stat. NO” position.
2 Turn in less than 4 seconds,
on the “Dyn. NO”
position.
S
T
The potentiometers are then
unlocked and the settings are
updated with the current
position of the potentiometers.
N
C
C
N
< 4 s
2
N
O
O
Notice:
N
If the mode button is already
in the “Stat. NO” position,
change mode previously and
then apply the standard
unlocking procedure.
Diagramm
8.8
(0.35)
37.3
(1.49)
4
Dimensions in mm (inch)
b
b1
1
2
3
1 FLG2-xxx120xx
2 FLG2-xxx180xx
3 FLG2-xxx250xx
151.4 (5.96)
73.9 (2.91)
b
140.2 (5.52) 133.9 (5.27)
117.6 (4.63) 203.9 (8.03)
b1
All dimensions in mm (inch)
④ Side is missing in open version
2016-03-09 17:40:10 | Online data sheet
Subject to change without notice
AUTOMATION LIGHT GRIDS | SICK
5
FLG2-20012021 | FLG
SWITCHING AUTOMATION LIGHT GRIDS
Recommended accessories
Other models and accessories www.sick.de/FLG
A
B
C
D
E
F
Brief description
Type
Part no.
Plug connectors and cables
Head A: female connector, M12, 4-pin, straight
Head B: cable
Cable: PVC, unshielded, 5 m
DOL-1204-G05M
6009866
H
I
J
K
L
M
N
O
P
Q
R
S
T
6
AUTOMATION LIGHT GRIDS | SICK
Online data sheet | 2016-03-09 17:40:10
Subject to change without notice
相关型号: