6054763 [SICK]
SAFETY LOCKING DEVICES;TR10-SRU03P
TR10 Lock
SAFETY LOCKING DEVICES
TR10-SRU03P | TR10 Lock
SAFETY LOCKING DEVICES
Ordering information
A
B
C
D
E
F
Type
TR10-SRU03P
Part no.
6054762
Other models and accessories www.sick.com/TR10_Lock
Detailed technical data
Features
H
I
Transponder
2
Sensor principle
Number of safe outputs
Coding
Uniquely coded
1,690 N (EN ISO 14119)
Locking force Fmax
With straight actuator EN ISO 14119
J
With angled actuator EN ISO 14119
With hinged actuator EN ISO 14119
K
L
1,300 N (EN ISO 14119)
Locking force FZh
Actuation directions
Approach speed
4
≥ 2 mm/s
Safety-related parameters
Safety integrity level
Category
M
N
O
P
Q
R
S
T
SIL3 (IEC 61508)
Category 4 (EN ISO 13849)
PL e (EN ISO 13849)
Performance level
9.1 x 10-10 (EN ISO 13849)
PFHD (mean probability of a dangerous fail-
ure per hour)
20 years (EN ISO 13849)
Type 4 (EN ISO 14119)
TM (mission time)
Type
High coding level (EN ISO 14119)
Actuator coding level
Safe state in the event of a fault
At least one safety-related semiconductor output (OSSD) is in the OFF state.
Functions
✔
Cascading
Interfaces
Cable
Connection type
2
SAFETY SWITCHES | SICK
Online data sheet | 2018-07-20 14:43:28
Subject to change without notice
TR10-SRU03P | TR10 Lock
SAFETY LOCKING DEVICES
Length of cable 3 m
Cable material PVC
Connecting cable length ≤ 200 m
Electrical data
II (IEC 61140)
Protection class
3
Contamination rating
Classification according to cULus
Usage category
Class 2
DC-13 (IEC 60947-5-1)
200 mA (24 V DC)
75 V
Rated operating current (voltage)
Rated insulation voltage Ui
Rated impulse withstand voltage Uimp
Supply voltage VS
1,000 V
24 V DC (20.4 V DC ... 26.4 V DC)
Semiconductor (OSSD)
≤ 200 mA
Type of output
Output current
400 mA, 100 ms 1)
2.5 W
Peak current
Power consumption
Response time
100 ms for the first switch, 50 ms for each subsequent switch 2)
600 ms
Enable time
100 ms
Risk time
7 s
Switch-on time
Locking principle
Power to release
1)
During switching on, locking, or unlocking.
2)
Time until the outputs are switched off.
Mechanical data
Weight
0.4 kg
ABS
Housing material
Locking bolt material
Mechanical life
Stainless steel 304
5 x 105 switching cycles
Ambient data
IP66 (IEC 60529)
IP67 (IEC 60529)
IP69K (IEC 60529)
Enclosure rating
0 °C ... +55 °C
Ambient operating temperature
Storage temperature
Vibration resistance
Shock resistance
EMC
–25 °C ... +75 °C
10 Hz ... 55 Hz (IEC 60068-2-6)
30 g, 11 ms (EN 60068-2-27)
IEC 60947-5-3
Classifications
ECl@ss 5.0
27272603
27272603
27272603
ECl@ss 5.1.4
ECl@ss 6.0
2018-07-20 14:43:28 | Online data sheet
Subject to change without notice
SAFETY SWITCHES | SICK
3
TR10-SRU03P | TR10 Lock
SAFETY LOCKING DEVICES
27272603
27272603
27272603
27272603
27272603
EC002593
EC002593
39122205
ECl@ss 6.2
ECl@ss 7.0
ECl@ss 8.0
ECl@ss 8.1
ECl@ss 9.0
ETIM 5.0
A
B
C
D
E
F
ETIM 6.0
UNSPSC 16.0901
Dimensional drawing (Dimensions in mm (inch))
Sensor with cable
33
(1.3)
10
(0.39)
Ø 9.525
(Ø 0.37)
H
I
J
22.5
(0.89)
8
(0.31)
9.5
(0.37)
K
L
Ø 6.5
(Ø 0.26)
M
N
O
P
Q
R
S
T
22.5
(0.89)
45
(1.77)
4
SAFETY SWITCHES | SICK
Online data sheet | 2018-07-20 14:43:28
Subject to change without notice
TR10-SRU03P | TR10 Lock
SAFETY LOCKING DEVICES
Actuator and mounting bracket
51.5
(2.03)
40
(1.57)
12.5
(0.49)
3
(0.12)
25
(0.98)
Connection diagram
WH
BN
GN
YE
GY
PK
BU
RD
White
Aux output (not safe)
Brown Voltage supply 24 V DC
Green Lock control
Yellow OSSD 2 input
Gray
Pink
Blue
Red
OSSD 1 output
OSSD 2 output
Voltage supply 0 V DC
OSSD 1 input
2018-07-20 14:43:28 | Online data sheet
Subject to change without notice
SAFETY SWITCHES | SICK
5
TR10-SRU03P | TR10 Lock
SAFETY LOCKING DEVICES
Series connection
A
B
C
D
E
F
Series connection with T-piece (without diagnostics)
1
1
1
1
1
2
2
2
2
2
7
6
H
I
3
4
5
4
5
4
5
4
5
4
① TR10 Lock safety locking device
② Connection cable with 8-pin, M12 male connector and 8-pin, M12 female connector (e.g., DSL-1208-xxxxx)
③ MLP1-XXT end connector
④ TR4-AK004C T-connector
⑤ Connection cable with 5-pin, M12 male connector and 5-pin, M12 female connector (e.g., DSL-1205-xxxxx)
⑥ Connecting cable with 5-pin, M12 female connector and flying leads (e.g., DOL-1205-xxxxx)
⑦ Safe evaluation unit
J
TR10 Lock safety locking device to UE48-2OS safety relay
K
L
+24 V DC
BN RD YE GN
2
7
8
4
TR10 Lock
3
Lock/
Unlock
5
6
1
M
N
O
P
Q
R
S
T
BU GY PK WH
Reset
S33 S11 S12 S31 A1 13 23 31
I1
PLC
k1
k2
UE48-2OS3D2
S34 S35 S21 S22 A2 14 24 32
K1
K2
0 V
E156017/00/2016-06-09
6
SAFETY SWITCHES | SICK
Online data sheet | 2018-07-20 14:43:28
Subject to change without notice
TR10-SRU03P | TR10 Lock
SAFETY LOCKING DEVICES
Series connection of three TR10 Lock safety locking devices to a Flexi Classic safety controller
+24 V DC
BN RD YE GN
2
7
8
4
TR10 Lock
3
1
5
6
BU GY PK WH
BN RD YE GN
Reset
2
7
8
4
TR10 Lock
3
1
5
6
BU GY PK WH
k1
k2
BN RD YE GN
2
7
8
4
TR10 Lock
3
1
5
6
BU GY PK WH
I1 I2 A1 X1 X2 S1 S2 S3
Lock/
Unlock
8
Function
FE
UE410-MU/XU
I3 I4 A2 Q1 Q2 Q3 Q4 EN
K1
K2
0 V
FE
E156014/00/2016-06-09
Recommended accessories
Other models and accessories www.sick.com/TR10_Lock
Brief description
Type
Part no.
Nuts and screws
10 pieces, Safety screws for mounting bracket of actuator
Safety screws M5 x 10
5334497
2018-07-20 14:43:28 | Online data sheet
Subject to change without notice
SAFETY SWITCHES | SICK
7
相关型号:
©2020 ICPDF网 联系我们和版权申明