PBSH-RB025S54S0BMA0Z
PBS Hygienic
PRESSURE SENSORS
PBSH-RB025S54S0BMA0Z | PBS Hygienic
PRESSURE SENSORS
Ordering information
A
B
C
D
E
F
Type
Part no.
PBSH-RB025S54S0BMA0Z
6051839
Other models and accessories www.sick.com/PBS_Hygienic
Illustration may differ
Detailed technical data
Features
Liquid, gaseous
Medium
Gauge pressure
Pressure type
0 bar ... 25 bar
Measuring range
Overpressure safety
Process temperature
Maximum ohmic load RA
Zero point adjustment
Output signal
H
I
2-fold
–20 °C ... +100 °C, +135 °C for max. 1 h
≤ 0.5 kΩ
Max. + 3 % of span
1 x PNP + 4 mA ... 20 mA
J
Rotatable housing
Display
K
L
1)
EHEDG approval
✔
1)
EHEDG conformity with connection per DIN 11851 only in combination with ASEPTO-STAR k-flex upgrade, sealing from Kieselmann GmbH.
Performance
≤ ± 0.5 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2
M
N
O
P
Q
R
S
T
Non-linearity
≤ ± 1 % of the span including non-linearity, hysteresis, zero point and full scale error (corre-
sponds to error of measurement as per IEC 61298-2)
Accuracy
≤ ± 0.5 % of span
Setting accuracy of switching outputs
Response time
3 ms
≤ ± 0.2 % of the span according to IEC 61298-2
Long-term drift/one-year stability
Typical TC of the zero point: in temperature range 0 °C ... 20 °C: 0.7% of the range / 10 K; in
temperature range 20 °C ... 80 °C: 0.2% of span / 10 K.
Typical TC of span: in temperature range 0 °C ... 80 °C: 0.1% of span / 10 K
Temperature coefficient in rated tempera-
ture range
0 °C ... +80 °C
Rated temperature range
Mechanics/electronics
Process connection
Conical coupling (DIN 11851) DN 40 with union nut
Stainless steel 1.4435 / 316L
Wetted parts
Medical white oil, FDA compliant according to CFR 172.878 and 21 CFR 178.3620(a), compli-
ant to USP, EP, and JP
Internal transmission fluid
2
FLUID SENSORS | SICK
Online data sheet | 2016-07-27 14:33:08
Subject to change without notice
PBSH-RB025S54S0BMA0Z | PBS Hygienic
PRESSURE SENSORS
Lower body: stainless steel 304, Plastic head: PC + ABS, Buttons: TPE-E, Display window: PC
M12 round connector x 1, 4-pin
Housing material
Electrical connection
Supply voltage
Power consumption
Total current consumption
Electrical safety
Insolation voltage
CE-conformity
Max. 320 mA (incl. switching current)
500 V DC
EMC directive: 2004/108/EC, EN 61326-2-3
Without seal
IP 65 / IP 67
✔
Seal
Enclosure rating
Protection class III
Ambient data
–20 °C ... +80 °C
–20 °C ... +80 °C
45 % ... 75 %
Ambient temperature
Storage temperature
Relative humidity
Shock load
Vibration load
Classifications
27371814
27371814
27371814
27371814
27371814
27371814
27371814
27371814
EC000243
EC000243
41112409
ECl@ss 5.0
ECl@ss 5.1.4
ECl@ss 6.0
ECl@ss 6.2
ECl@ss 7.0
ECl@ss 8.0
ECl@ss 8.1
ECl@ss 9.0
ETIM 5.0
ETIM 6.0
UNSPSC 16.0901
2016-07-27 14:33:08 | Online data sheet
Subject to change without notice
FLUID SENSORS | SICK
3
PBSH-RB025S54S0BMA0Z | PBS Hygienic
PRESSURE SENSORS
Dimensional drawing (Dimensions in mm (inch))
Conical coupling (DIN 11851) with union nut
A
B
C
D
E
F
38
1.49)
29.5
(1.16)
(
35
1.37)
(
(
16
0.62)
d9
G
D
DIN 11851
ø d9
G
ø
D
g
h
DN 40
56.0
(2.20)
Rd 65 x 1/6
78
(3.07)
10 20
(0.39) (0.78)
H
I
DN 50
68.5
(2.69)
Rd 78 x 1/6
92
(3.62)
11
(0.43)
20
(0.78)
Connection type
J
M12 round connector x 1, 4-pin
2
K
L
1
3
M
N
O
P
Q
R
S
T
4
① L+: Positive supply connection
② QA: Analog output
③ M: Negative supply connection
④ C/Q1: Switching output 1 (with IO-Link: communication / switching output 1)
4
FLUID SENSORS | SICK
Online data sheet | 2016-07-27 14:33:08
Subject to change without notice