PHT-RB010SD30S0ALS0Z [SICK]
PRESSURE SENSORS;型号: | PHT-RB010SD30S0ALS0Z |
厂家: | SICK AG |
描述: | PRESSURE SENSORS |
文件: | 总5页 (文件大小:432K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PHT-RB010SD30S0ALS0Z
PHT
PRESSURE SENSORS
PHT-RB010SD30S0ALS0Z | PHT
PRESSURE SENSORS
Ordering information
A
B
C
D
E
F
Type
Part no.
PHT-RB010SD30S0ALS0Z
6039359
Other models and accessories www.sick.com/PHT
Illustration may differ
Detailed technical data
Features
H
I
Liquid, gaseous
Gauge pressure
0 bar ... 10 bar
–20 °C ... +150 °C
4 mA ... 20 mA
✔
Medium
Pressure type
Measuring range
Process temperature
Output signal
EHEDG approval
J
K
L
Performance
Non-linearity
Accuracy
≤ ± 0.2 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2
≤ ± 0.5 % of the span optional 0.25 % of span (adjusted in vertical mounting position with low-
er pressure connection)
≤ ± 0.1 % of the span
≤ 10 ms
Non-repeatability
M
N
O
P
Q
R
S
T
Response time (10 % ... 90 %)
Long-term drift/one-year stability
≤ 0.2 % of the span
Mean TC of zero: ≤ 0.2% of span / 10 K for measuring ranges 0 bar ... 0.6 bar up to 0 bar ...
25 bar, Mean TC of zero: ≤ 0.25 % of span/ 10 K with pressure range 0 bar ... 0.4 bar≤ 0.25 %
of span/ 10 K, with pressure range 0 bar ... 0.4 bar, Mean TC of zero: ≤ 0.4% of span / 10 K
for measuring range 0 bar ... 0.25 bar, Mean TC of span ≤ 0.2 % of span / 10 K
Temperature coefficient in rated tempera-
ture range
0 °C ... +80 °C
Rated temperature range
Mechanics/electronics
Process connection
Wetted parts
Clamp (DIN 32676) DN 32
Stainless steel 1.4435
Synthetic oil, FDA approved
Stainless steel 1.4571
Internal transmission fluid
Housing material
L-connector (DIN EN 175301-803 A), IP 65
Electrical connection
Supply voltage
10 V DC ... 30 V DC
14 V DC ... 30 V DC with output signal 0 V ... 10 V
2
FLUID SENSORS | SICK
Online data sheet | 2017-01-30 18:33:08
Subject to change without notice
PHT-RB010SD30S0ALS0Z | PHT
PRESSURE SENSORS
11 V DC ... 30 V DC with output signal 4 mA ... 20 mA and field housing
Overvoltage protection: 36 V DC
Electrical safety
Short-circuit protection: QA towards M
Reverse polarity protection: L+ to M
Protection class: III
500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even in the
event of a fault)
Dielectric strength
EMC directive: 2004/108/EC, EN 61326-2-3
CE-conformity
Weight sensor
Seal
Approx. 500 g
Without seal
IP 65
Enclosure rating
Protection class III
✔
Ambient data
–20 °C ... +80 °C
Ambient temperature
Storage temperature
Shock load
–40 °C ... +100 °C
500 g according to IEC 60068-2-27 (mechanical shock)
15 g according to IEC 60068-2-6 (vibration under resonance)
Vibration load
Classifications
27200614
27200614
27200614
27200614
27200614
27200614
27200614
27200614
EC002476
EC002476
41112410
ECl@ss 5.0
ECl@ss 5.1.4
ECl@ss 6.0
ECl@ss 6.2
ECl@ss 7.0
ECl@ss 8.0
ECl@ss 8.1
ECl@ss 9.0
ETIM 5.0
ETIM 6.0
UNSPSC 16.0901
2017-01-30 18:33:08 | Online data sheet
Subject to change without notice
FLUID SENSORS | SICK
3
PHT-RB010SD30S0ALS0Z | PHT
PRESSURE SENSORS
Dimensional drawing (Dimensions in mm (inch))
Housing with L-connector (DIN 175301-803 A), IP 65
A
B
C
D
E
F
approx. 48
(1.89)
Ø 27
(1.06)
With accuracy
0.5 %
H
64 (2.52)
84 (3.31)
0.25 %
H
I
Connection type
2-wire
3-wire
L+/ Q
L+
A
+
+
-
J
L-connector
-
(DIN EN 175301-803 A
1
2
Q
A
3
3
K
L
-
+
-
M
M
+
L+
L+/ Q
Q
A
A
+
-
M12 x 1, 4-pin
+
-
4
3
2
4
3
2
1
1
+
-
-
M
N
O
P
Q
R
S
T
M
M
+
L+/Q
L+
A
+
-
Stainless steel
field housing
+
-
1
2 3 4 5
1
2 3 4 5
Test-
M
-
-
Q
Test+
M
A
+
+
Flying leads
+
-
+
-
brn
brn
L+/Q
L+
A
wht
grn
Q
A
+
-
-
M
M
grn
+
Power supply
Load
4
FLUID SENSORS | SICK
Online data sheet | 2017-01-30 18:33:08
Subject to change without notice
相关型号: