WLL180T-N432 [SICK]
FIBER-OPTIC SENSORS AND FIBERS;型号: | WLL180T-N432 |
厂家: | SICK AG |
描述: | FIBER-OPTIC SENSORS AND FIBERS |
文件: | 总6页 (文件大小:761K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
WLL180T-P432
WLL180T
FIBER-OPTIC SENSORS AND FIBERS
WLL180T-P432 | WLL180T
FIBER-OPTIC SENSORS AND FIBERS
Ordering information
A
B
C
D
E
F
Type
WLL180T-P432
Part no.
6039093
Other models and accessories www.sick.com/WLL180T
Illustration may differ
Detailed technical data
Features
Stand-alone
Device type
H
I
Fiber-optic photoelectric sensor
10.5 mm x 34.6 mm x 71.9 mm
Rectangular
Sensor/detection principle
Dimensions (W x H x D)
Housing design (light emission)
Sensing range max.
0 m ... 20 m, Through-beam system 1) 2)
J
0 mm ... 1,400 mm, Proximity system 3) 4)
0 ... 18 m, Through-beam system 1) 2)
Sensing range
5)
Focus
K
L
Visible red light
LED 6)
Type of light
Light source
Approx. 65° 5)
650 nm
Angle of dispersion
Wave length
Adjustment
M
N
O
P
Q
R
S
T
Menu-controlled
Single teach-in button
Cable
Without time delay
Off delay
On delay
ON and OFF delay
One shot
Time type
Programmable, 0 ms, 9,999 ms
Display
Delay time
Indication
1)
Sensing range with 8 ms response time. Reduction with shorter response time (see tables LL3/WLL180T).
LL3-TX01.
2)
3)
Objects to be sensed with 90% reflectivity (based on DIN 5033 white standard). Sensing range with 8 ms response time. Reduction with shorter response time (see
tables LL3/WLL180T).
4)
LL3-DK06.
5)
See LL3 fiber-optic data.
6)
Average service life: 100,000 h at T = +25 °C.
U
2
PHOTOELECTRIC SENSORS | SICK
Online data sheet | 2017-04-06 17:11:29
Subject to change without notice
WLL180T-P432 | WLL180T
FIBER-OPTIC SENSORS AND FIBERS
LED status display / 2x 4-character digital dual displays, Set value (green indicator) and actual
value (red indicator) are displayed simultaneously, display of parameters
Display
1)
Sensing range with 8 ms response time. Reduction with shorter response time (see tables LL3/WLL180T).
2)
3)
LL3-TX01.
Objects to be sensed with 90% reflectivity (based on DIN 5033 white standard). Sensing range with 8 ms response time. Reduction with shorter response time (see
tables LL3/WLL180T).
4)
LL3-DK06.
5)
See LL3 fiber-optic data.
6)
Average service life: 100,000 h at T = +25 °C.
U
Mechanics/electronics
12 V DC ... 24 V DC 1)
≤ 10 % 2)
Supply voltage
Ripple
≤ 50 mA 3)
PNP
Power consumption
Output type
1
Number of switching outputs
Switching mode
Light/dark switching
Manually selectable
≤ 100 mA
Switching mode selector
Output current Imax.
Response time
≤ 16 µs, ≤ 70 µs, ≤ 250 µs, ≤ 2,000 µs, ≤ 8,000 µs 4)
31.2 kHz
7.1 kHz
2 kHz
Switching frequency
250 Hz
62.5 Hz
Multifunctional input MF
Input
Cable, 4-wire, 2 m 5)
PVC
Connection type
Cable material
0.2 mm²
Conductor cross-section
Circuit protection
A 6)
B 7)
C 8)
D 9)
III
Protection class
Weight
25 g
ABS/PCPlastic
Housing material
Enclosure rating
IP50 10)
BEF-WLL180 mounting bracket
Items supplied
1)
+- 10%.
2)
May not exceed or fall below U tolerances.
v
3)
4)
5)
6)
Without load.
Selectable.
Do not bend below 0 °C.
A = V connections reverse-polarity protected.
S
7)
8)
9)
B = inputs and output reverse-polarity protected.
C = interference suppression.
D = outputs overcurrent and short-circuit protected.
10)
With correctly attached fibre-optic cable LL3 and closed protection hood.
2017-04-06 17:11:29 | Online data sheet
Subject to change without notice
PHOTOELECTRIC SENSORS | SICK
3
WLL180T-P432 | WLL180T
FIBER-OPTIC SENSORS AND FIBERS
–25 °C ... +55 °C
Ambient operating temperature
Ambient storage temperature
UL File No.
A
B
C
D
E
F
–40 °C ... +70 °C
NRKH2.E300503 & NRKH8.E300503
1)
+- 10%.
2)
May not exceed or fall below U tolerances.
v
3)
4)
5)
6)
Without load.
Selectable.
Do not bend below 0 °C.
A = V connections reverse-polarity protected.
S
7)
8)
9)
B = inputs and output reverse-polarity protected.
C = interference suppression.
D = outputs overcurrent and short-circuit protected.
10)
With correctly attached fibre-optic cable LL3 and closed protection hood.
Classifications
27270905
27270905
27270905
27270905
27270905
27270905
27270905
27270905
EC002651
EC002651
39121528
ECl@ss 5.0
ECl@ss 5.1.4
ECl@ss 6.0
ECl@ss 6.2
ECl@ss 7.0
ECl@ss 8.0
ECl@ss 8.1
ECl@ss 9.0
ETIM 5.0
H
I
ETIM 6.0
J
UNSPSC 16.0901
K
L
Adjustments possible
WLL180T
7
8
9 ß
M
N
O
P
Q
R
S
T
–
+
OUT
MODE
TEACH
3
à
á
③ Locking the fiber-optic cables
⑦ LED indicator orange, lights up when switching output is active
⑧ Numeric display 2 x 4-digit; green: switching threshold, operating mode; red: actual value, Teach-in and function parameter
⑨ Step pushbutton > (manual switching threshold: higher/next function parameter)
⑩ Step pushbutton < (manual switching threshold: lower/previous function parameter)
⑪ Mode/Enter-button
⑫ Teach-in button
4
PHOTOELECTRIC SENSORS | SICK
Online data sheet | 2017-04-06 17:11:29
Subject to change without notice
WLL180T-P432 | WLL180T
FIBER-OPTIC SENSORS AND FIBERS
Connection diagram
Cd-136
brn
+ (L+)
blu
- (M)
blk
Q
wht
Ext. Input
Dimensional drawing (Dimensions in mm (inch))
Stand-alone
12.2
(0.48)
37.3 (1.47)
3
(0.12)
3.6
(0.14)
10.5
(0.41)
68.9 (2.71)
3
~ 180°
4
2
1
4
3.6
(0.14)
5
18.8
(0.74)
Ø 4.2
(0.17)
10
27.8 (1.09) (0.39)
7
(0.27)
55.4 (2.18)
① Sender LED, installation of LL3 fibre-optic cable (sender fibre)
② Receiver, installation of LL3 fibre optic cable (receiver fibre)
③ Protective hood opens approx. 180°
④ Connection
⑤ Mounting bracket, included with delivery
Recommended accessories
Other models and accessories www.sick.com/WLL180T
Brief description
Type
Part no.
Mounting brackets and plates
Mounting bracket, steel, zinc coated, without mounting hardware
BEF-WLL170
BEF-WLL180
5306574
5325812
Other mounting accessories
Rail end piece for block mounting, Stainless steel, mounting hardware included
BF-EB01-W190
FC
5313011
5304141
Cutter for fibers, supplied with LL3