MAX71071H+ [SILERGY]

Dual-Channel Isolated Metrology ADCs;
MAX71071H+
型号: MAX71071H+
厂家: SILERGY    SILERGY
描述:

Dual-Channel Isolated Metrology ADCs

光电二极管
文件: 总11页 (文件大小:255K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MAX71071/MAX71071H  
Dual-Channel Isolated Metrology ADCs  
General Description  
Benefi ts and Features  
Accurately Measure Voltage and Current  
The MAX71071/MAX71071H are dual-channel iso-  
lated analog-to-digital converters (ADCs) for use with  
a compatible MAX71xxx host. The device provides  
current and voltage measurements to the host while  
the host provides control, command, and power to the  
MAX71071/MAX71071H. A pulse transformer provides  
the isolated data, clock, and power path between the  
device and host, eliminating the need for additional  
isolation components in the measurement subsystem.  
These metrology ADCs operate over the industrial tem-  
perature range and come in a 10-pin μSOP package.  
Dual 24-Bit ADC  
0.1% Accuracy Over 2000:1 Dynamic Range  
Exceeds IEC 62053/ANSI C12.20 Standards  
On-Chip Temperature Sensor Enables Localized  
Digital Temperature Compensation  
Galvanic Isolation Through Pulse Transformer  
Provides Power, Bidirectional Data, and Timing  
Reference  
1.4mA Typical Consumption  
On-Chip PLL and Power Monitoring  
Ordering Information appears at end of data sheet.  
Block Diagram  
MAX71071/MAX71071H  
REFERENCE  
TEMP SENSOR  
P
R
E
A
M
P
INVP  
INVN  
INIP  
ADC  
PLL  
FIR  
HOST MICROCONTROLLER  
(MAX71xxx)  
P
R
E
A
M
P
ISO  
I/F  
ADC  
FIR  
ININ  
Rev 2; 4/16  
MAX71071/MAX71071H  
Dual-Channel Isolated Metrology ADCs  
Absolute Maximum Ratings  
(All voltages with respect to V  
.)  
Digital Pins  
SSA  
Supplies and Ground Pins  
TEST....................................-10mA to +10mA, -0.5V to +3.6V  
Operating Junction Temperature (peak, 100ms).............+140°C  
Operating Junction Temperature (continuous)................+125°C  
Storage Temperature........................................ -45°C to +165°C  
Solder Temperature (10s duration) .................................+250°C  
V
V
...................................................................-0.5V to +3.6V  
...................................................................-0.1V to +0.1V  
CC  
SS  
Analog Input Pins  
INP, INN, SP, SN .....-10mA to +10mA, -0.5V to (V  
+ 0.5V)  
CC  
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these  
or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect  
device reliability.  
Package Thermal Characteristics (Note 1)  
µSOP  
Junction-to-Ambient Thermal Resistance (θ  
)
Junction-to-Case Thermal Resistance (θ )................42°C/W  
JC  
JA  
Multilayer Board ................................................113.10°C/W  
Single-Layer Board..................................................180°C/W  
Note 1: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a four-layer  
board.  
Recommended External Components  
NAME  
FROM  
TO  
FUNCTION  
VALUE  
UNITS  
C1  
V
V
Bypass capacitor for supply  
1.0  
µF  
CC  
SS  
To establish proper bias for INVN/INVP and  
ININ/INIP pins  
R1, R2, R3, R4  
Sensor  
GND  
1.0  
kΩ  
INVN  
1kΩ  
INVP  
1kΩ  
ININ  
1kΩ  
INIP  
MAX71071/MAX71071H  
1kΩ  
VSS  
1µF  
VCC  
Figure 1. Recommended External Components Circuit  
Silergy Corp  
2  
www.silergy.com  
MAX71071/MAX71071H  
Dual-Channel Isolated Metrology ADCs  
Recommended Operating Conditions  
PARAMETER  
CONDITIONS  
MIN  
2.5  
TYP  
MAX  
3.6  
UNITS  
V
V
Supply Voltage  
CC  
Operating Temperature Range  
-40  
+85  
°C  
Perfiormance Specifi cations  
(Limits are production tested at T = +25°C. Limits over the operating temperature range and relevant supply voltage range are guar-  
A
anteed by design and characterization.)  
PARAMETER  
CONDITIONS  
MIN  
TYP  
1.2  
MAX  
UNITS  
SUPPLY CURRENT  
V
= 3.3V, voltage ADC preamp  
CC  
V
Current, Normal Operation  
1.6  
mA  
CC  
bypassed  
V
REF  
V
(22), V  
Output Voltage  
T = +22°C  
A
1.1925  
-2.4  
1.195  
1.1975  
+2.4  
V
REF  
REF  
V
Power Supply Sensitivity  
REF  
mV/V  
ΔV  
/ΔV  
REF  
CC  
V
(T) = V  
(22) + (T - 22) x TC1 +  
NOM  
REF  
V
Defi nition  
V
NOM  
2
(T - 22) x TC2 (Note 2)  
IF TRIMBGB AVAILABLE (NOT 00)  
V
V
(T) Deviation from  
REF  
(T)  
NOM  
(Note 3)  
0
ppm/°C  
[(V  
x [10 /62]  
(T) - V  
(T))/V  
(T)]  
REF  
NOM  
NOM  
6
IF TRIMBGB NOT AVAILABLE (TRIMBGB = 00)  
V
V
(T) Deviation from  
REF  
(T)  
NOM  
(Note 3)  
0
ppm/°C  
LSB  
[(V  
x [10 /62]  
(T) - V  
(T))/V  
(T)]  
REF  
NOM  
NOM  
6
V
VOLTAGE MONITOR  
CC  
BNOM: Nominal Value,  
= +22°C  
V
= 3.0V  
120  
CC  
T
A
V
Voltage  
V
= 3.0 + (BSENSE - 120) x 0.0244 (Note 4)  
-150  
V
CC  
CC  
Measurement Error  
+150  
mV  
Silergy Corp  
3  
www.silergy.com  
MAX71071/MAX71071H  
Dual-Channel Isolated Metrology ADCs  
Perfiormance Specifi cations (continued)  
(Limits are production tested at T = +25°C. Limits over the operating temperature range and relevant supply voltage range are guar-  
A
anteed by design and characterization.)  
PARAMETER  
CONDITIONS  
MIN  
TYP  
MAX  
UNITS  
TEMPERATURE MONITOR  
T
T
: Nominal Value,  
= +22°C  
NOM  
945  
0
LSB  
°C  
A
Temperature Error  
T
= -40°C, -10°C, +55°C, +85°C (Note 3)  
A
TETIME: Duration of  
Temperature Measurement  
V
= 3.0V  
14  
30  
ms  
CC  
POWER PULSE  
Power Pulse Frequency  
PULSE IO  
1.638  
MHz  
V
0.28  
-
CC  
SP Output V  
(ONE Pulse)  
I
= 1mA  
= 1mA  
= 1mA  
= 1mA  
V
V
V
V
OH  
OH  
SN Output V (ONE Pulse)  
I
I
I
0.287  
OL  
OL  
OH  
OL  
V
0.28  
-
CC  
SN Output V  
(ZERO Pulse)  
OH  
SP Output V (ZERO Pulse)  
OL  
0.287  
PREAMP  
Gain = 14x  
-2%  
-2%  
-2%  
14  
9
+2%  
+2%  
+2%  
V/V  
V/V  
V/V  
m°  
Gain = 9x  
Gain = 4x  
4
Phase Shift  
1
Phase Shift Variation vs. Supply  
(Note 3)  
-10  
-0.1  
7.5  
+10  
+0.1  
24  
m°/V  
Phase Shift Variation vs.  
Temperature  
(Note 3)  
m°/°C  
µA  
Input Current  
Preamp gain = 4x, 9x, 14x  
13  
ADC CONVERTER  
Usable Input Range (I  
- I  
)
-250/gain  
250/gain  
mV  
PK  
NP NN  
THD (FIRST 10 HARMONICS)  
V
= 65Hz, 64kpts FFT,  
IN  
Preamp Gain = 1x  
85  
85  
dB  
Blackman-Harris window  
V = 65Hz, 64kpts FFT,  
IN  
250mV /Preamp Gain,  
PK  
Preamp Gain = 4x, 9x, 14x  
dB  
Blackman-Harris window  
Silergy Corp  
4
www.silergy.com  
MAX71071/MAX71071H  
Dual-Channel Isolated Metrology ADCs  
Perfiormance Specifi cations (continued)  
(Limits are production tested at T = +25°C. Limits over the operating temperature range and relevant supply voltage range are guar-  
A
anteed by design and characterization.)  
PARAMETER  
CONDITIONS  
MIN  
TYP  
MAX  
UNITS  
20mV /Preamp Gain,  
PK  
V
= 65Hz, 64kpts FFT,  
IN  
85  
dB  
Preamp Gain = 4x, 9x, 14x  
Input Impedance  
Blackman-Harris window  
Preamp bypassed  
Preamp = 4x  
20  
6.5  
3.5  
2.3  
40  
18  
12  
6.3  
4.3  
kΩ  
Preamp = 9x  
9.1  
6.3  
Preamp = 14x  
LSB SIZE  
Preamp Gain = 14x  
Preamp Gain = 9x  
Preamp Gain = 4x  
FIR length = 100  
FIR length = 100  
FIR length = 100  
22.9  
35.5  
79.9  
nV/LSB  
nV/LSB  
nV/LSB  
Digital Full Scale  
L = FIR Length  
FIR length = 100  
±1,000,000  
LSB  
ADC Gain Error vs. % Power  
Supply Variation  
V
V
= 250mV , 55Hz  
120  
ppm/%  
IN  
PK  
Current Channel Gain Variation  
Input Offset, Preamp Bypassed  
= 250mV , 55Hz (Note 3)  
90  
+4  
ppm/%  
mV  
IN  
PK  
-4  
Note 2: This relationship describes the nominal behavior of V  
Note 3: Guaranteed by design, not production tested.  
Note 4: This is a definition, and it is not a measured quantity.  
at different temperatures.  
REF  
Silergy Corp  
5  
www.silergy.com  
MAX71071/MAX71071H  
Dual-Channel Isolated Metrology ADCs  
Pin Confi guration  
INVN  
INVP  
TEST  
SN  
1
2
3
4
5
10  
9
ININ  
INIP  
MAX71071/  
MAX71071H  
8
V
V
SS  
7
CC  
SP  
N.C.  
6
µSOP  
Pin Description  
PIN  
1
NAME  
INVN  
INVP  
TEST  
SN  
FUNCTION  
Voltage Channel Negative Input  
Voltage Channel Positive Input  
2
3
Test Mode Enable. Must be grounded in normal operation.  
Transformer Negative  
4
5
SP  
Transformer Positive  
6
N.C.  
Not Connected  
7
V
Power Bypass. Connect 1µF capacitor to ground.  
CC  
8
V
Ground. The 1µF capacitor from V  
Current Channel Positive Input  
Current Channel Negative Input  
to V must be connected to this pin.  
SS  
CC SS  
9
INIP  
ININ  
10  
Silergy Corp  
6  
www.silergy.com  
MAX71071/MAX71071H  
Dual-Channel Isolated Metrology ADCs  
9x, and 10 is 14x. The inputs are V referenced, and the  
SS  
output of the preamp connects directly to the ADC.  
Detailed Description  
The MAX71071/MAX71071H are dual-channel isolated  
metrology analog-to-digital converters (ADCs) that are com-  
patible with MAX71xxx hosts. The device digitizes a current  
signal from a shunt type current sensor and/or a voltage  
signal from a resistor-divider. The two input channels of  
the MAX71071/MAX71071H are identical except that the  
voltage channel contains an option to bypass the preamp.  
Bandgap  
The device includes an on-chip precision bandgap volt-  
age reference that incorporates autozero techniques as  
well as production trims to minimize errors caused by  
component mismatch and drift. The result is a voltage  
output with a predictable temperature coefficient that is  
compensated in firmware by the host.  
The device continuously sends ADC data to the host. The  
host can request the device to return certain ancillary data  
such as temperature monitor output. The MAX71071/  
MAX71071H communicate with the host through a pulse  
transformer to provide isolation from the high-voltage  
power domain.  
Temperature Monitor  
The temperature monitor block does a temperature  
and a supply measurement whenever the MAX71071/  
MAX71071H receives an instruction from a MAX71xxx  
host requesting for STEMP or BSENSE. This request  
causes the MAX71071/MAX71071H to return STEMP or  
BSENSE from the previous measurement and to initiate  
a new measurement for both.  
The MAX71071/MAX71071H include a rectifier, two star-  
ing preamp/ADC channels, bandgap, temperature moni-  
tor, PLL, and BIAS block.  
Rectifi er  
PLL  
The active rectifier in the device rectifies the power pulses  
received from the host through the isolation transformer  
The PLL locks to the incoming power pulses to create ref-  
erence clocks for the ADC and communications interface  
to the host.  
to create the V  
that drive the data bits out of the MAX71071/MAX71071H  
and through the transformer.  
voltage. The block also has the drivers  
CC  
Pulse IO  
The pulse IO block in the MAX71071/MAX71071H  
receives the incoming data from the MAX71xxx host  
and transmits the data back to the host. The integrated  
output is applied to the input of a comparator, and the  
comparator output is captured by a flip-flop at the end of  
the integration time.  
ISO Interfiace  
The isolated interface block receives the incoming data  
from the host and transmits data back to the host through  
the isolation transformer.  
Preamp  
The preamp is a low-noise differential amplifier. The INP  
and INN pins are the differential inputs to the preamp. It  
has three gain settings (4x, 9x, and 14x) The gain is con-  
trolled by the two preamp gain control bits: 00 is 4x, 01 is  
ADC  
A proven Teridian delta-sigma ADC digitizes the voltage  
and current-sense voltages.  
Silergy Corp  
7  
www.silergy.com  
MAX71071/MAX71071H  
Dual-Channel Isolated Metrology ADCs  
Functional Diagram  
INVN  
INVP  
ININ  
INIP  
IBIAS  
PLL  
VREF  
VBIAS  
GEN  
BANDGAP  
PREAMP  
PREAMP  
VREF  
VBIAS  
GEN  
ADC  
ADC  
REG  
V3P3  
FIR  
FIR  
CLOCK  
GEN  
TMUXOUT  
TEMP/  
VCC  
MONITOR  
VCO_OUT  
INTERFACE AND  
MODE CONTROL  
TEST  
TEMP  
GND  
ISO  
INTERFACE  
SP  
SN  
MAX71071/MAX71071H  
Silergy Corp  
8  
www.silergy.com  
MAX71071/MAX71071H  
Dual-Channel Isolated Metrology ADCs  
Ordering Infiormation  
Package Infiormation  
PART  
TEMP RANGE  
-40°C to +85°C  
-40°C to +85°C  
-40°C to +85°C  
-40°C to +85°C  
PIN-PACKAGE  
10 µSOP  
Package outline information is appended to this document.  
Land patterns (footprints) are inserted below.  
MAX71071+  
MAX71071+T  
MAX71071H+*  
MAX71071H+T*  
10 µSOP  
10 μSOP  
10 μSOP  
+Denotes a lead(Pb)-free/RoHS-compliant package.  
T = Tape and reel.  
*Future product—contact factory for availability.  
Silergy Corp  
9  
www.silergy.com  
MAX71071/MAX71071H  
Dual-Channel Isolated Metrology ADCs  
Revision History  
REVISION REVISION  
PAGES  
DESCRIPTION  
CHANGED  
NUMBER  
DATE  
0
1
2
3/14  
Initial release  
1/15  
Updated the Benefi ts and Features section  
1
4/16  
Rebranding only  
Copyright © 2016 Silergy Corp Proprietary information. For Silergy customer use only. Unauthorized distribution or  
duplication prohibited. Silergy cannot assume responsibility for use of any circuitry other than circuitry entirely embodied  
in a Silergy product. No circuit patent licenses are implied. Silergy reserves the right to change the circuitry and  
specifications without notice at any time. Typical parametric values provided in this data sheet are for guidance only  
and are not guaranteed.  

相关型号:

MAX71071H+T

Dual-Channel Isolated Metrology ADCs
SILERGY

MAX710C/D

3.3V/5V or Adjustable, Step-Up/Down DC-DC Converters
MAXIM

MAX710ESE

3.3V/5V or Adjustable, Step-Up/Down DC-DC Converters
MAXIM

MAX710EVKIT

Evaluation Kit for the MAX710/MAX711
MAXIM

MAX711

3.3V/5V or Adjustable, Step-Up/Down DC-DC Converters
MAXIM

MAX711C/D

3.3V/5V or Adjustable, Step-Up/Down DC-DC Converters
MAXIM

MAX711ESE

3.3V/5V or Adjustable, Step-Up/Down DC-DC Converters
MAXIM

MAX711ESE+

Switching Regulator, Voltage-mode, 0.7A, PDSO16, 0.150 INCH, MS-012C, SOIC-16
MAXIM

MAX711ESE+T

Switching Regulator, Voltage-mode, 0.7A, PDSO16, 0.150 INCH, MS-012C, SOIC-16
MAXIM

MAX711ESE-T

Switching Regulator, Voltage-mode, 0.7A, PDSO16, 0.150 INCH, MS-012C, SOIC-16
MAXIM

MAX712

NiCd/NiMH Battery Fast-Charge Controllers
MAXIM

MAX712-MAX713

NiCd/NiMH Battery Fast-Charge Controllers
MAXIM