IS100M100G4BP-QS4 [SILICOM]

Silicom 100G Intelligent Bypass Switch;
IS100M100G4BP-QS4
型号: IS100M100G4BP-QS4
厂家: Silicom    Silicom
描述:

Silicom 100G Intelligent Bypass Switch

文件: 总10页 (文件大小:519K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
IS100  
Silicom 100G Intelligent Bypass Switch  
Product Description  
Silicom 100G Intelligent QSFP28  
Bypass switch (IS100) is Silicom  
forth generation of an active  
external Bypass switch that protects  
network integrity from network  
failures and network maintenance. The Silicom intelligent Bypass switch (IS100) is a self-generating heartbeat and controls the  
network switch mode of operation.  
The Silicom IS100G1U is a 1U host system which supports up to two modules. A module supports one Bypass segment per  
module.  
The Silicom IS100 supports 100 Gigabit Ethernet Multimode Fiber (100GBase-SR4) ,(100G Base-SR10 ) and 100 Gigabit Single  
mode fiber (100GBase-LR4) network standards. Each 100G Bypass module includes two MPO / LC ports for network ports, and  
two QSFP28 ports for the attached in-line network system.  
The Silicom Intelligent Bypass switch (IS100) supports four modes of operations: Inline, Bypass, Tap and Linkdrop. In Inline mode,  
the IS100 diverts inline network traffic to attached in-line network system. In Bypass mode, the IS100 does not divert the traffic to  
the attached in-line network system and diverts it to other network link. In Tap mode, incoming traffic in port NET0 is mirrored to  
port MON0 and incoming traffic in port NET1 is mirrored to port MON1.In Linkdrop mode the IS100 disables the links on the  
network ports (NET0, NET1). The IS100 simulates switch / router cable disconnection.  
The IS100 generates the heartbeat packets and transmits the heartbeat packet to the in-line Monitor / Network appliance port, the  
Monitor Network appliance receives the heartbeat packets and transmits is to its other port (bridges the heartbeat packet). The  
IS100 detects back the heartbeat packet and maintains the Inline mode.  
The IS100 sets to Bypass, Tap or Linkdrop when it does not receive back the heartbeat packet from the Network / Monitor  
appliance. When the Network / Monitor appliance recovers, it transmits back the heartbeat packet and the Intelligent switch sets to  
Inline. The IS100 bypasses its Ethernet Monitor ports on event of power failure, Link failure, in-line software application system  
hang or user request.  
The IS100 includes Double Bypass Safe architecture. The Silicom Double Bypass safe architecture is based on two Bypass routing  
circuitry: An Active Bypass circuitry and Passive Bypass circuitry. If the internal active bypass routing circuitry fails, the passive  
Bypass routing circuitry is activated.  
Page 1  
Silicom Ltd. Connectivity Solutions  
The IS100 can be configured using:  
• Simple CLI configuration management via a serial communication console port, Ethernet port using Telnet or SSH.  
• Web interface management interface.  
• SNMP.  
The Silicom IS100 Bypass switch includes centralized management to all Bypass segments in the box.  
The IS100G includes two redundant 90 240 V AC power supply or two redundant -48 DC power supply.  
Figure: 1 Front panel view of IS100G  
Figure: 2 Front panel view of IS100G with 2 modules  
Key Features  
Self generating heartbeat pulses No driver or management port is required to generate pulses  
Sets to Bypass when it detects in-line system failure  
Sets to Bypass when it detects in-line system link failure  
Sets to Bypass when it detects in-line software application system hang  
Sets to Bypass on Power failure  
Sets to Normal when it detects in-line system recovery  
Double Safe Bypass architecture with two routing circuitries  
Centralized managements  
Two on Board Watch Dog Timer (WDT) Controllers  
Software programmable time out interval  
Software Programmable WDT Enable / Disable  
Independent Bypass / Normal / Tap /Linkdrop operation in every module  
Supports up to two 100G Bypass segment in a 1U chassis  
Supports TAP mode of operation  
Simple CLI configuration management via serial port  
Telnet management interface via network management port  
SSH management interface via network management port  
Supports SNMP version 1, 2c, 3 (SHA, AES)  
Page 2  
Silicom Ltd. Connectivity Solutions  
Supports remote log  
Supports TACACS+  
Support RADIUS  
Supports NTP  
Supports time zone  
Supports multi configuration backup  
Support Two ports link feature if one of the network ports link fails it will drop the link on the other network port as well  
Two redundant power supplies  
Optional -48V DC power supplies  
IS100M100G4BP-CSR4  
Supports Short Range Fiber 100 Gigabit Ethernet with Optical module CFP4 (100GBase-SR4 50um)  
IS100M100G4BP-SR10  
Supports Short Range (100m) Fiber 100 Gigabit Ethernet with Optical module CXP (100GBase-SR10 )  
IS100M100G4BP-CLR4  
Supports Long Reach Fiber 100 Gigabit Ethernet with Optical module CFP4 (100GBase-LR4)  
Technical Specifications  
Bypass Specifications  
Routing  
Transmit heart beat packet every 3mS 10Sec. Default 5mS  
WDT Interval (Software  
Programmable):  
Verification packets received every 10mS 50Sec. Default 20mSec  
Double Bypass  
Transmit heart beat packet every 300mS 60Sec. Default 7Sec  
Verification packets received every 1S 253Sec. Default 20Sec  
Production Default configuration  
Mode at Power up:  
Bypass  
Heartbeat:  
Activated  
Bypass Switch is ready and in-  
line device responds to  
heartbeat:  
Change to Normal  
In-line device responds to  
heartbeat:  
Normal  
Bypass  
In-line device does not  
respond heartbeat:  
Page 3  
Silicom Ltd. Connectivity Solutions  
Mode at Power 0ff:  
Heartbeat Packet:  
Bypass  
Internetwork Packet Exchange  
IS1001U: Bypass Switch 1U Host System Technical Specifications  
Dockings:  
Front holders  
AC: 90-240 VAC Auto-Select  
-48 (-75 -36) VDC  
Voltage Input:  
With no module : 240W  
Power Consumption:  
Size:  
With one LR4 module (with 90% utilization):405W  
With 2 LR4modules (with 90% utilization):552W  
435mm x 586 mm x 44 mm ( 17.12” x 23.07” x 1.732”)  
Wide x Depth X Height  
Weight:  
10Kg  
Operating Humidity:  
Operating Temperature:  
Storage Temperature:  
EMC Certifications:  
0%90%, non-condensing  
0°C 40°C (32°F 104°F)  
-20°C65°C (-4°F149°F)  
Class B FCC / CE / VCCI  
12.65 Years  
Operating conditions: Environment: GB, Temperature: 40.00 °C  
Current mode: Operating  
MTBF*:  
FR Units: FIT  
Default prediction Method: Telcordia Issue 4  
IS1001U: Bypass Switch 1U Host System LEDs & Switches Specifications  
Two Power LEDs: PS1, PS2  
PS1: power on Light Green.  
PS2: power on Light Green.  
System Status LEDs: 3 LEDs  
SysOK: system normal operation Light Green.  
WhoI’m: in rack identification – Blinking Green.  
LEDs:  
SysUP: system init during power up Light Yellow.  
Alm/Fail: system alarm Light Red.  
Module Power LEDs: 3BICOLOR LEDs  
1. M1: module1 power on Light Green.  
module1 fail Light Red.  
2. M2: module2 power on Light Green.  
module2 fail Light Red  
Sys PWR: Turn all system ON  
From ON to OFF In order to switch system off required press and hold this pushbutton during  
8s  
From OFF to ON simple push will turn system on.  
Module ON/OFF power: 2 switches  
Switches  
MxPWR: Turn Module x power (x = 1,2)  
From ON to OFF In order to switch module off required press and hold this pushbutton during  
5s  
From OFF to ON simple push will turn module on.  
Reset:  
Page 4  
Silicom Ltd. Connectivity Solutions  
Small micro-switch stand behind hidden hole allows reset the system if this is necessary.  
Management  
RJ-11 serial port  
RJ-45 Ethernet  
USB port  
Connectors:  
IS100M100G4BP-QS4 (50um)  
Fiber Gigabit Ethernet Technical Specifications (100GBase-SR4) Adapters:  
IEEE Standard / Network  
Fiber Gigabit Ethernet, 100GBase-SR4 (850nM)  
topology:  
Data Transfer Rate:  
4 x 25.78125G for each lane  
4x Multimode fiber:50um  
Cables and Operating  
distance:  
*50m maximum on OM3 MMF  
*75m maximum on OM4 MMF  
Theoretical Distance Defined as half a distance  
Output Transmit Power:  
As defined by IEEE 802.3bm  
As defined by IEEE 802.3bm  
Optical Receive Sensitivity:  
Insertion Loss ( Passive:  
Normal Mode)  
Typical: 1.2dB  
Maximum: 2.1dB  
Insertion Loss ( Passive:  
Bypass Mode)  
Typical: 1.2dB  
Maximum: 2.1dB  
Power Consumption:  
Size:  
~30W  
158.2mm x163.9 mm x 40.5 mm  
Wide x Depth x Height  
Weight:  
980gr / 34.57oz  
Operating Humidity:  
Operating Temperature:  
Storage Temperature:  
EMC Certifications:  
Safety:  
0%90%, non-condensing  
0°C 40°C (32°F 104°F)  
-20°C65°C (-4°F149°F)  
Class A FCC / CE  
CB/UL  
170 Years.  
Operating conditions: Environment: GB, Temperature: 40.00 °C  
Current mode: Operating  
MTBF*:  
FR Units: FIT  
Default prediction Method: Telcordia Issue 4  
Connectors:  
Network: 2 MPO OM4  
Page 5  
Silicom Ltd. Connectivity Solutions  
Monitor: 2 CFP4  
IS100M100G4BP-QL4  
Fiber Gigabit Ethernet Technical Specifications (100GBase-LR4) Adapters:  
IEEE Standard / Network  
topology:  
Fiber Gigabit Ethernet, 100GBase-LR4  
range of 4 wavelength (per 100G LR4 spec)  
Data Transfer Rate:  
4 x 25.78125G in four wavelengths  
Network ports Cables and  
Operating distance:  
Single mode fiber: four wavelengths  
5000m maximum at 9 um **  
Insertion Loss ( Passive:  
Normal Mode)  
Typical: 1.2dB  
Maximum: 2.1dB  
Insertion Loss ( Passive:  
Bypass Mode)  
Typical: 1.2dB  
Maximum: 2.1dB  
Power Consumption:  
Size:  
~30W  
158.2mm x163.9 mm x 40.5 mm  
Wide x Depth x Height  
Operating Humidity:  
Operating Temperature:  
Storage Temperature:  
EMC Certifications:  
Safety:  
0%90%, non-condensing  
0°C 40°C (32°F 104°F)  
-20°C65°C (-4°F149°F)  
Class A FCC / CE  
CB/UL  
170 Years.  
Operating conditions: Environment: GB, Temperature: 40.00 °C  
Current mode: Operating  
MTBF*:  
FR Units: FIT  
Default prediction Method: Telcordia Issue 4  
Network: 2 MPO  
Monitor: 2 CFP4  
Connectors  
IS100M100G4BP-SR10  
Fiber Gigabit Ethernet Technical Specifications (100GBase-SR10) Adapters:  
IEEE Standard / Network  
Fiber Gigabit Ethernet, 100GBase-SR10 (850nM)  
topology:  
Data Transfer Rate:  
10 x 10.3125G for each lane  
10x Multimode fiber  
*50m maximum on OM3 MMF  
*75m maximum on OM4 MMF  
Cables and Operating  
distance:  
Page 6  
Silicom Ltd. Connectivity Solutions  
Theoretical Distance Defined as half a distance  
Output Transmit Power per  
lane:  
Max : 3 DBM  
Min: 7.6 DBM  
Optical Receive Sensitivity per  
lane:  
Max -5.4 DBM  
Power Consumption:  
Operating Humidity:  
Operating Temperature:  
Storage Temperature:  
EMC Certifications:  
Safety:  
~30W  
0%90%, non-condensing  
0°C 40°C (32°F 104°F)  
-20°C65°C (-4°F149°F)  
Class B / FCC / CE / VCCI  
UL  
49 Years.  
MTBF:  
*According to Telcordia SR-332 Issue 2. Environmental condition GB (Ground, Fixed, and  
Controlled). Ambient temperature 40°C.  
Network: 2 MPO OM4  
Monitor: 2 CXP  
Connectors:  
IS100M100G4BP-CSR4 (50um)  
Fiber Gigabit Ethernet Technical Specifications (100GBase-SR4) Adapters:  
IEEE Standard / Network  
Fiber Gigabit Ethernet, 100GBase-SR4 (850nM)  
topology:  
Data Transfer Rate:  
4 x 25.78125G for each lane  
4x Multimode fiber:50um  
*50m maximum on OM3 MMF  
*75m maximum on OM4 MMF  
Theoretical Distance Defined as half a distance  
Cables and Operating  
distance:  
Output Transmit Power:  
Optical Receive Sensitivity:  
Power Consumption:  
Weight  
As defined by IEEE 802.3bm  
As defined by IEEE 802.3bm  
~30W  
1.2Kg  
Operating Humidity:  
Operating Temperature:  
0%90%, non-condensing  
0°C 40°C (32°F 104°F)  
-20°C65°C (-4°F149°F)  
Storage Temperature:  
Page 7  
Silicom Ltd. Connectivity Solutions  
EMC Certifications:  
Safety:  
Class B / FCC / CE / VCCI  
UL  
57 Years.  
MTBF:  
*According to Telcordia SR-332 Issue 2. Environmental condition GB (Ground, Fixed, and  
Controlled). Ambient temperature 40°C.  
Network: 2 MPO OM4  
Monitor: 2 CFP4  
Connectors:  
IS100M100G4BP-CLR4  
Fiber 100Gigabit Ethernet Technical Specifications (100G Base-LR4) Adapters:  
IEEE Standard / Network  
topology:  
Fiber Gigabit Ethernet, 100GBase-LR4  
range of 4 wavelength (per 100G LR4 spec)  
Data Transfer Rate:  
4 x 25.78125G in four wavelengths  
Netowrk ports Cables and  
Operating distance:  
Single mode fiber: four wavelengths  
5000m maximum at 9 um **  
Power Consumption:  
Weight  
~30W  
1.2kg  
Operating Humidity:  
Operating Temperature:  
Storage Temperature:  
EMC Certifications:  
Safety:  
0%90%, non-condensing  
0°C 40°C (32°F 104°F)  
-20°C65°C (-4°F149°F)  
Class B FCC / CE / VCCI /  
UL  
MTBF*:  
> 150,000 hours  
Network: 2 MPO  
Monitor: 2 CFP4  
Connectors  
Page 8  
Silicom Ltd. Connectivity Solutions  
Figure: 3 Normal Mode Functional Block Diagram  
Figure: 4 Bypass Mode Functional Block Diagram  
Figure: 5 Tap Mode Functional Block Diagram  
Page 9  
Silicom Ltd. Connectivity Solutions  
Figure: 6 Linkdrop Mode Functional Block Diagram  
Order Information  
P/N  
Description  
Notes  
IS100G-Q-US  
Bypass Switch 1U Host System  
90-240 VAC Auto-Select, US cable  
IS100G-Q-48  
Bypass Switch 1U Host System  
Power supply -48VDC  
4 ports 100 Gigabit QSFP28 (SR4) fiber  
Intelligent Bypass Switch module  
SR4 MMF Bypass 100G (SR4 on the  
IS100M100G4BP-QS4  
Network and Monitor ports)  
4 ports 100 Gigabit QSFP28 (LR4) fiber  
Intelligent Bypass Switch module  
LR4 SMF Bypass 100G (LR4 on the  
IS100M100G4BP-QL4  
IS100M100G4BP-QL4S4  
IS100M100G4BP-CSR4  
IS100M100G4BP-CLR4  
IS100M100G4BP-SR101  
Network and Monitor ports)  
4 ports100 Gigabit QSFP28 (LR4/SR4) fiber  
Intelligent Bypass Switch module  
LR4 SMF Bypass 100G (LR4 on the  
Network and SR4 on the Monitor ports)  
4 ports 100 Gigabit CFP4 (SR4) fiber Intelligent SR4 MMF Bypass 100G (SR4 on the  
Bypass Switch module  
Network and Monitor ports)  
4 ports100 Gigabit CFP4 (LR4) fiber Intelligent  
Bypass Switch module  
LR4 SMF Bypass 100G (LR4 on the  
Network and Monitor ports)  
4 ports100 Gigabit CXP (SR10) fiber Intelligent SR10 Bypass 100G (SR10 on the Network  
Bypass Switch module and Monitor ports)  
1V1  
Page 10  
Silicom Ltd. Connectivity Solutions  

相关型号:

IS100M100G4BP-SR101

Silicom 100G Intelligent Bypass Switch
SILICOM
ETC

IS110

Silicon Controlled Rectifier, 10A I(T)RMS, 10000mA I(T), 100V V(DRM), 100V V(RRM), 1 Element, TO-220AB, TO-220, 3 PIN
HUTSON

IS1100

Switching Mode Power Supply
ISOCOM

IS1101

Transistor Output Optocoupler, 1-Element, 3750V Isolation, LEAD FREE PACKAGE-4
ISOCOM

IS1102

Switching Mode Power Supply
ISOCOM

IS1103

Switching Mode Power Supply
ISOCOM