IS100
Silicom 100G Intelligent Bypass Switch
Product Description
Silicom 100G Intelligent QSFP28
Bypass switch (IS100) is Silicom
forth generation of an active
external Bypass switch that protects
network integrity from network
failures and network maintenance. The Silicom intelligent Bypass switch (IS100) is a self-generating heartbeat and controls the
network switch mode of operation.
The Silicom IS100G1U is a 1U host system which supports up to two modules. A module supports one Bypass segment per
module.
The Silicom IS100 supports 100 Gigabit Ethernet Multimode Fiber (100GBase-SR4) ,(100G Base-SR10 ) and 100 Gigabit Single
mode fiber (100GBase-LR4) network standards. Each 100G Bypass module includes two MPO / LC ports for network ports, and
two QSFP28 ports for the attached in-line network system.
The Silicom Intelligent Bypass switch (IS100) supports four modes of operations: Inline, Bypass, Tap and Linkdrop. In Inline mode,
the IS100 diverts inline network traffic to attached in-line network system. In Bypass mode, the IS100 does not divert the traffic to
the attached in-line network system and diverts it to other network link. In Tap mode, incoming traffic in port NET0 is mirrored to
port MON0 and incoming traffic in port NET1 is mirrored to port MON1.In Linkdrop mode the IS100 disables the links on the
network ports (NET0, NET1). The IS100 simulates switch / router cable disconnection.
The IS100 generates the heartbeat packets and transmits the heartbeat packet to the in-line Monitor / Network appliance port, the
Monitor Network appliance receives the heartbeat packets and transmits is to its other port (bridges the heartbeat packet). The
IS100 detects back the heartbeat packet and maintains the Inline mode.
The IS100 sets to Bypass, Tap or Linkdrop when it does not receive back the heartbeat packet from the Network / Monitor
appliance. When the Network / Monitor appliance recovers, it transmits back the heartbeat packet and the Intelligent switch sets to
Inline. The IS100 bypasses its Ethernet Monitor ports on event of power failure, Link failure, in-line software application system
hang or user request.
The IS100 includes Double Bypass Safe architecture. The Silicom Double Bypass safe architecture is based on two Bypass routing
circuitry: An Active Bypass circuitry and Passive Bypass circuitry. If the internal active bypass routing circuitry fails, the passive
Bypass routing circuitry is activated.
Page 1
Silicom Ltd. Connectivity Solutions
The IS100 can be configured using:
• Simple CLI configuration management via a serial communication console port, Ethernet port using Telnet or SSH.
• Web interface management interface.
• SNMP.
The Silicom IS100 Bypass switch includes centralized management to all Bypass segments in the box.
The IS100G includes two redundant 90 – 240 V AC power supply or two redundant -48 DC power supply.
Figure: 1 – Front panel view of IS100G
Figure: 2 – Front panel view of IS100G with 2 modules
Key Features
•
Self generating heartbeat pulses – No driver or management port is required to generate pulses
Sets to Bypass when it detects in-line system failure
Sets to Bypass when it detects in-line system link failure
Sets to Bypass when it detects in-line software application system hang
Sets to Bypass on Power failure
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Sets to Normal when it detects in-line system recovery
Double Safe Bypass architecture with two routing circuitries
Centralized managements
Two on Board Watch Dog Timer (WDT) Controllers
Software programmable time out interval
Software Programmable WDT Enable / Disable
Independent Bypass / Normal / Tap /Linkdrop operation in every module
Supports up to two 100G Bypass segment in a 1U chassis
Supports TAP mode of operation
Simple CLI configuration management via serial port
Telnet management interface via network management port
SSH management interface via network management port
Supports SNMP version 1, 2c, 3 (SHA, AES)
Page 2
Silicom Ltd. Connectivity Solutions
•
•
•
•
•
•
•
•
•
Supports remote log
Supports TACACS+
Support RADIUS
Supports NTP
Supports time zone
Supports multi configuration backup
Support Two ports link feature – if one of the network ports link fails it will drop the link on the other network port as well
Two redundant power supplies
Optional -48V DC power supplies
IS100M100G4BP-CSR4
•
Supports Short Range Fiber 100 Gigabit Ethernet with Optical module CFP4 (100GBase-SR4 50um)
IS100M100G4BP-SR10
•
Supports Short Range (100m) Fiber 100 Gigabit Ethernet with Optical module CXP (100GBase-SR10 )
IS100M100G4BP-CLR4
•
Supports Long Reach Fiber 100 Gigabit Ethernet with Optical module CFP4 (100GBase-LR4)
Technical Specifications
Bypass Specifications
Routing
Transmit heart beat packet every 3mS – 10Sec. Default 5mS
WDT Interval (Software
Programmable):
Verification packets received every 10mS – 50Sec. Default 20mSec
Double Bypass
Transmit heart beat packet every 300mS – 60Sec. Default 7Sec
Verification packets received every 1S – 253Sec. Default 20Sec
Production Default configuration
Mode at Power up:
Bypass
Heartbeat:
Activated
Bypass Switch is ready and in-
line device responds to
heartbeat:
Change to Normal
In-line device responds to
heartbeat:
Normal
Bypass
In-line device does not
respond heartbeat:
Page 3
Silicom Ltd. Connectivity Solutions
Mode at Power 0ff:
Heartbeat Packet:
Bypass
Internetwork Packet Exchange
IS1001U: Bypass Switch 1U Host System Technical Specifications
Dockings:
Front holders
AC: 90-240 VAC Auto-Select
-48 (-75 – -36) VDC
Voltage Input:
With no module : 240W
Power Consumption:
Size:
With one LR4 module (with 90% utilization):405W
With 2 LR4modules (with 90% utilization):552W
435mm x 586 mm x 44 mm ( 17.12” x 23.07” x 1.732”)
Wide x Depth X Height
Weight:
10Kg
Operating Humidity:
Operating Temperature:
Storage Temperature:
EMC Certifications:
0%–90%, non-condensing
0°C – 40°C (32°F – 104°F)
-20°C–65°C (-4°F–149°F)
Class B FCC / CE / VCCI
12.65 Years
Operating conditions: Environment: GB, Temperature: 40.00 °C
Current mode: Operating
MTBF*:
FR Units: FIT
Default prediction Method: Telcordia Issue 4
IS1001U: Bypass Switch 1U Host System LEDs & Switches Specifications
Two Power LEDs: PS1, PS2
•
•
PS1: power on – Light Green.
PS2: power on – Light Green.
System Status LEDs: 3 LEDs
•
SysOK: system normal operation – Light Green.
WhoI’m: in rack identification – Blinking Green.
LEDs:
•
SysUP: system init during power up – Light Yellow.
Alm/Fail: system alarm – Light Red.
•
Module Power LEDs: 3BICOLOR LEDs
1. M1: module1 power on – Light Green.
module1 fail – Light Red.
2. M2: module2 power on – Light Green.
module2 fail – Light Red
Sys PWR: Turn all system ON
From ON to OFF – In order to switch system off required press and hold this pushbutton during
8s
From OFF to ON – simple push will turn system on.
Module ON/OFF power: 2 switches
Switches
MxPWR: Turn Module x power (x = 1,2)
From ON to OFF – In order to switch module off required press and hold this pushbutton during
5s
From OFF to ON – simple push will turn module on.
Reset:
Page 4
Silicom Ltd. Connectivity Solutions
Small micro-switch stand behind hidden hole allows reset the system if this is necessary.
Management
RJ-11 serial port
RJ-45 Ethernet
USB port
Connectors:
IS100M100G4BP-QS4 (50um)
Fiber Gigabit Ethernet Technical Specifications – (100GBase-SR4) Adapters:
IEEE Standard / Network
Fiber Gigabit Ethernet, 100GBase-SR4 (850nM)
topology:
Data Transfer Rate:
4 x 25.78125G for each lane
4x Multimode fiber:50um
Cables and Operating
distance:
*50m maximum on OM3 MMF
*75m maximum on OM4 MMF
Theoretical Distance – Defined as half a distance
Output Transmit Power:
As defined by IEEE 802.3bm
As defined by IEEE 802.3bm
Optical Receive Sensitivity:
Insertion Loss ( Passive:
Normal Mode)
Typical: 1.2dB
Maximum: 2.1dB
Insertion Loss ( Passive:
Bypass Mode)
Typical: 1.2dB
Maximum: 2.1dB
Power Consumption:
Size:
~30W
158.2mm x163.9 mm x 40.5 mm
Wide x Depth x Height
Weight:
980gr / 34.57oz
Operating Humidity:
Operating Temperature:
Storage Temperature:
EMC Certifications:
Safety:
0%–90%, non-condensing
0°C – 40°C (32°F – 104°F)
-20°C–65°C (-4°F–149°F)
Class A FCC / CE
CB/UL
170 Years.
Operating conditions: Environment: GB, Temperature: 40.00 °C
Current mode: Operating
MTBF*:
FR Units: FIT
Default prediction Method: Telcordia Issue 4
Connectors:
Network: 2 MPO OM4
Page 5
Silicom Ltd. Connectivity Solutions
Monitor: 2 CFP4
IS100M100G4BP-QL4
Fiber Gigabit Ethernet Technical Specifications – (100GBase-LR4) Adapters:
IEEE Standard / Network
topology:
Fiber Gigabit Ethernet, 100GBase-LR4
range of 4 wavelength (per 100G LR4 spec)
Data Transfer Rate:
4 x 25.78125G in four wavelengths
Network ports Cables and
Operating distance:
Single mode fiber: four wavelengths
5000m maximum at 9 um **
Insertion Loss ( Passive:
Normal Mode)
Typical: 1.2dB
Maximum: 2.1dB
Insertion Loss ( Passive:
Bypass Mode)
Typical: 1.2dB
Maximum: 2.1dB
Power Consumption:
Size:
~30W
158.2mm x163.9 mm x 40.5 mm
Wide x Depth x Height
Operating Humidity:
Operating Temperature:
Storage Temperature:
EMC Certifications:
Safety:
0%–90%, non-condensing
0°C – 40°C (32°F – 104°F)
-20°C–65°C (-4°F–149°F)
Class A FCC / CE
CB/UL
170 Years.
Operating conditions: Environment: GB, Temperature: 40.00 °C
Current mode: Operating
MTBF*:
FR Units: FIT
Default prediction Method: Telcordia Issue 4
Network: 2 MPO
Monitor: 2 CFP4
Connectors
IS100M100G4BP-SR10
Fiber Gigabit Ethernet Technical Specifications – (100GBase-SR10) Adapters:
IEEE Standard / Network
Fiber Gigabit Ethernet, 100GBase-SR10 (850nM)
topology:
Data Transfer Rate:
10 x 10.3125G for each lane
10x Multimode fiber
*50m maximum on OM3 MMF
*75m maximum on OM4 MMF
Cables and Operating
distance:
Page 6
Silicom Ltd. Connectivity Solutions
Theoretical Distance – Defined as half a distance
Output Transmit Power per
lane:
Max : 3 DBM
Min: – 7.6 DBM
Optical Receive Sensitivity per
lane:
Max -5.4 DBM
Power Consumption:
Operating Humidity:
Operating Temperature:
Storage Temperature:
EMC Certifications:
Safety:
~30W
0%–90%, non-condensing
0°C – 40°C (32°F – 104°F)
-20°C–65°C (-4°F–149°F)
Class B / FCC / CE / VCCI
UL
49 Years.
MTBF:
*According to Telcordia SR-332 Issue 2. Environmental condition – GB (Ground, Fixed, and
Controlled). Ambient temperature 40°C.
Network: 2 MPO OM4
Monitor: 2 CXP
Connectors:
IS100M100G4BP-CSR4 (50um)
Fiber Gigabit Ethernet Technical Specifications – (100GBase-SR4) Adapters:
IEEE Standard / Network
Fiber Gigabit Ethernet, 100GBase-SR4 (850nM)
topology:
Data Transfer Rate:
4 x 25.78125G for each lane
4x Multimode fiber:50um
*50m maximum on OM3 MMF
*75m maximum on OM4 MMF
Theoretical Distance – Defined as half a distance
Cables and Operating
distance:
Output Transmit Power:
Optical Receive Sensitivity:
Power Consumption:
Weight
As defined by IEEE 802.3bm
As defined by IEEE 802.3bm
~30W
1.2Kg
Operating Humidity:
Operating Temperature:
0%–90%, non-condensing
0°C – 40°C (32°F – 104°F)
-20°C–65°C (-4°F–149°F)
Storage Temperature:
Page 7
Silicom Ltd. Connectivity Solutions
EMC Certifications:
Safety:
Class B / FCC / CE / VCCI
UL
57 Years.
MTBF:
*According to Telcordia SR-332 Issue 2. Environmental condition – GB (Ground, Fixed, and
Controlled). Ambient temperature 40°C.
Network: 2 MPO OM4
Monitor: 2 CFP4
Connectors:
IS100M100G4BP-CLR4
Fiber 100Gigabit Ethernet Technical Specifications – (100G Base-LR4) Adapters:
IEEE Standard / Network
topology:
Fiber Gigabit Ethernet, 100GBase-LR4
range of 4 wavelength (per 100G LR4 spec)
Data Transfer Rate:
4 x 25.78125G in four wavelengths
Netowrk ports Cables and
Operating distance:
Single mode fiber: four wavelengths
5000m maximum at 9 um **
Power Consumption:
Weight
~30W
1.2kg
Operating Humidity:
Operating Temperature:
Storage Temperature:
EMC Certifications:
Safety:
0%–90%, non-condensing
0°C – 40°C (32°F – 104°F)
-20°C–65°C (-4°F–149°F)
Class B FCC / CE / VCCI /
UL
MTBF*:
> 150,000 hours
Network: 2 MPO
Monitor: 2 CFP4
Connectors
Page 8
Silicom Ltd. Connectivity Solutions
Figure: 3 – Normal Mode Functional Block Diagram
Figure: 4 – Bypass Mode Functional Block Diagram
Figure: 5 – Tap Mode Functional Block Diagram
Page 9
Silicom Ltd. Connectivity Solutions
Figure: 6 – Linkdrop Mode Functional Block Diagram
Order Information
P/N
Description
Notes
IS100G-Q-US
Bypass Switch 1U Host System
90-240 VAC Auto-Select, US cable
IS100G-Q-48
Bypass Switch 1U Host System
Power supply -48VDC
4 ports 100 Gigabit QSFP28 (SR4) fiber
Intelligent Bypass Switch module
SR4 MMF Bypass 100G – (SR4 on the
IS100M100G4BP-QS4
Network and Monitor ports)
4 ports 100 Gigabit QSFP28 (LR4) fiber
Intelligent Bypass Switch module
LR4 SMF Bypass 100G – (LR4 on the
IS100M100G4BP-QL4
IS100M100G4BP-QL4S4
IS100M100G4BP-CSR4
IS100M100G4BP-CLR4
IS100M100G4BP-SR101
Network and Monitor ports)
4 ports100 Gigabit QSFP28 (LR4/SR4) fiber
Intelligent Bypass Switch module
LR4 SMF Bypass 100G – (LR4 on the
Network and SR4 on the Monitor ports)
4 ports 100 Gigabit CFP4 (SR4) fiber Intelligent SR4 MMF Bypass 100G – (SR4 on the
Bypass Switch module
Network and Monitor ports)
4 ports100 Gigabit CFP4 (LR4) fiber Intelligent
Bypass Switch module
LR4 SMF Bypass 100G – (LR4 on the
Network and Monitor ports)
4 ports100 Gigabit CXP (SR10) fiber Intelligent SR10 Bypass 100G – (SR10 on the Network
Bypass Switch module and Monitor ports)
1V1
Page 10
Silicom Ltd. Connectivity Solutions
相关型号:
IS110
Silicon Controlled Rectifier, 10A I(T)RMS, 10000mA I(T), 100V V(DRM), 100V V(RRM), 1 Element, TO-220AB, TO-220, 3 PIN
HUTSON
©2020 ICPDF网 联系我们和版权申明