IS40M10G8BP-SRD [SILICOM]
Silicom 40G/10G Intelligent Bypass Switch;型号: | IS40M10G8BP-SRD |
厂家: | Silicom |
描述: | Silicom 40G/10G Intelligent Bypass Switch |
文件: | 总11页 (文件大小:494K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
IS40 Bypass Switch
Silicom 40G/10G Intelligent Bypass Switch
Product Description
Silicom 40G Intelligent Bypass switch (IS40) is
Silicom second generation of an active external
Bypass switch that protects network integrity from
network failures and network maintenance. The
Silicom intelligent Bypass switch (IS40) is a self-
generating heartbeat and controls the network switch mode of operation.
The Silicom IS401U is a 1U host system which supports up to three modules. The 1U host system can support mix of 40G Bypass
module and dual rate 10G/1G Bypass modules. A 40G module supports one Bypass segment per module. A dual rate 10G/1G
Bypass module supports two Bypass segment in a module.
The Silicom IS40 supports 40 Gigabit Ethernet Multimode Fiber (40GBase-SR4) and 40 Gigabit Single mode fiber (40GBase-LR4)
network standards. Each 40G Bypass module includes two MPO / LC ports for network ports, and two QSFP+ ports for the
attached in-line network system.
The Silicom IS40 supports dual rate 10/1 Gigabit Ethernet Multimode Fiber (10GBase-SR , 1000Base-SX) and 10/1 Gigabit Single
mode fiber (10GBase-LR, 1000Base-LX) network standards. Each 10G Bypass module Network includes four LC Duplex Monitor
ports and four SFP+ ports for the attached in-line network system.
The Silicom Intelligent Bypass switch (IS40) supports three modes of operations: Inline, Bypass, Tap and Linkdrop. In Inline mode,
the IS40 diverts inline network traffic to attached in-line network system. In Bypass mode, the IS40 does not divert the traffic to the
attached in-line network system and diverts it to other network link. In Tap mode, incoming traffic in port NET0 is mirrored to port
MON0 and incoming traffic in port NET1 is mirrored to port MON1.In Linkdrop mode the IS40 disables the links on the network
ports (NET0, NET1). The IS40 simulates switch / router cable disconnection.
The IS40 generates the heartbeat packets and transmits the heartbeat packet to the in-line Monitor / Network appliance port, the
Monitor Network appliance receives the heartbeat packets and transmits is to its other port (bridges the heartbeat packet). The
IBS40 detects back the heartbeat packet and maintains the Inline mode.
The IS40 sets to Bypass, Tap or Linkdrop when it does not receive back the heartbeat packet from the Network / Monitor appliance.
When the Network / Monitor appliance recovers, it transmits back the heartbeat packet and the Intelligent switch sets to Inline. The
IS40 bypasses its Ethernet Monitor ports on event of power failure, Link failure, in-line software application system hang or user
request.
The IS40 includes Double Bypass Safe architecture. The Silicom Double Bypass safe architecture is based on two Bypass routing
circuitry: An Active Bypass circuitry and Passive Bypass circuitry. If the internal active bypass routing circuitry fails, the passive
Page 1
Silicom Ltd. Connectivity Solutions
Bypass routing circuitry is activated.
The IS40 can be configured using:
•
Simple CLI configuration management via a serial communication console port, Ethernet port using Telnet or SSH.
•
•
Web interface management interface.
SNMP
The Silicom IS40 Bypass switch includes centralized management to all Bypass segments in the box.
The IS40G includes two redundant 90 – 240 V AC power supply or two redundant -48 DC power supply.
Figure: 1 – Front panel view of IS40
2X10 Gigabit Bypass Modules and 1X40 Gigabit Module
Key Features
•
Self generating heartbeat pulses – No driver or management port is required to generate pulses
Sets to Bypass when it detects in-line system failure
Sets to Bypass when it detects in-line system link failure
Sets to Bypass when it detects in-line software application system hang
Sets to Bypass on Power failure
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Sets to Normal when it detects in-line system recovery
Double Safe Bypass architecture with two routing circuitries
Centralized managements
Two on Board Watch Dog Timer (WDT) Controllers
Software programmable time out interval
Software Programmable WDT Enable / Disable
Independent Bypass / Normal / Tap operation in every module
Supports up to three 40G Bypass segment in a 1U chassis
Supports TAP mode of operation
Simple CLI configuration management via serial port
Telnet management interface via network management port
SSH management interface via network management port
Page 2
Silicom Ltd. Connectivity Solutions
•
•
•
•
•
•
•
•
•
•
Supports SNMP version 1, 2c, 3 (SHA, AES)
Supports remote log
Supports TACACS+
Support RADIUS
Supports NTP
Supports time zone
Supports multi configuration backup
Support Two ports link feature – if one of the network ports link fails it will drop the link on the other network port as well
Two redundant power supplies
Optional -48V DC power supplies
IS40M40G4BP-QS4
•
Supports Short Range Fiber 40 Gigabit Ethernet (40GBase-SR4 50um)
IS40M40G4BP-QB4
•
• Supports Short Range Fiber 40 Gigabit Ethernet (40GBase-SR BiDi)
IS40M40G4BP-QL4
•
Supports Long Reach Fiber 40 Gigabit Ethernet (40GBase-LR4)
IS40M108BP-SRD
•
Supports Short Range Fiber 10 Gigabit Ethernet (10GBase-SR)
Supports Short Range Fiber Gigabit Ethernet (1000Base-SX)
•
IS40M108BP-LRD
•
Supports Long Reach Fiber 10 Gigabit Ethernet (10GBase-LR)
Supports Long Range Fiber Gigabit Ethernet (1000Base-LX)
•
Technical Specifications
Bypass Specifications
Routing
Transmit heart beat packet every 3mS – 10Sec. Default 5mS
Verification packets received every 10mS – 50Sec. Default 20mSec
Double Bypass
WDT Interval (Software
Programmable):
Transmit heart beat packet every 300mS – 60Sec. Default 7Sec
Verification packets received every 1S – 253Sec. Default 20Sec
Production Default configuration
Mode at Power up:
Bypass
Heartbeat:
Activated
Bypass Switch is ready and in-
line device responds to
heartbeat:
Change to Normal
Page 3
Silicom Ltd. Connectivity Solutions
In-line device responds to
heartbeat:
Normal
Bypass
In-line device does not
respond heartbeat:
Mode at Power 0ff:
Heartbeat Packet:
Bypass
Internetwork Packet Exchange
IS401U: Bypass Switch 1U Host System Technical Specifications
Dockings:
Front holders
AC: 90-240 VAC Auto-Select
-48 (-75 – -36) VDC
Voltage Input:
Power Consumption:
Size:
180W
438mm x 586 mm x 44 mm ( 17.24” x 23.07” x 1.73”)
Wide x Depth X Height
Operating Humidity:
Operating Temperature:
Storage Temperature:
0%–90%, non-condensing
0°C – 40°C (32°F – 104°F)
-20°C–65°C (-4°F–149°F)
4 hot swap Fans
4 wires connections on each fan (12V,GND,TACH and PWM)
Specifications (maximum operation condition) of one Fan
SPL- 61dB(A)
Fans
Current – 0.92A
Air flow – 28.6 CFM
EMC Certifications:
Safety:
Class A FCC / CE / BSMI
CB / UL
48 years
MTBF*:
According to Telcordia SR-332 issue 3, environment GB, temperature 40 °C
IS401U: Bypass Switch 1U Host System LEDs Specifications
FRONT
Two Power LEDs: PS1, PS2
PS1: Green LED will light when power is on and off if there is a failer in power supply module or
when extracrting the power supply module from the system.
PS2: Green LED will light when power is on and off if there is a failer in power supply module or
when extracrting the power supply module from the system.
System Status LEDs: 3 LEDs
Sys OK: System Normal Operation – Light Green.
Who I’m: in rack identification – Blinking Green.
Sys UP: System Init during power up and during shutdown – Light Yellow.
ALM: System Alarm – Light Red.
LEDs:
Module Power LEDs:
1. M1: module1 power on – Light Green. M2: module2 power on – Light Green.
2. M3: module3 power on – Light Green.
BACK
One bi-color LED indication that integrated on each power supply module:
Power Switch On – Geern color.
Standby(AC/DC In,Only +5VSB output) – Blinking Green color.
Power Fail – Red color.
Page 4
Silicom Ltd. Connectivity Solutions
Internal Fan Fail – Blinking Red.
Push button to power the system (PWR).
From ON to OFF –
Press and hold this push button during 4 second will perform firmware shutdown
press and hold this push button during 8second will perform power shoutdown.
From OFF to ON – simple push will turn system on.
Reset (RST):
Switches
Small micro-switch stand behind hidden hole :
Press and hold for more than 1 sec will perform restart to the system.
Management Ports:
RJ-45 Ethernet (MGNT ETH)
RJ-45 serial port (RS-232)
USB port (RS-232)
Connectors:
IS40M40G4BP-QS4 (50um)
Fiber Gigabit Ethernet Technical Specifications – (40GBase-SR4) Adapters:
IEEE Standard / Network
Fiber Gigabit Ethernet, 40GBase-SR4 (850nM)
topology:
Data Transfer Rate:
40G per port
Multimode fiber:50um
Cables and Operating
distance:
*50m maximum on OM3 MMF
*75m maximum on OM4 MMF
Theoretical Distance – Defined as half a distance
Typical: -2 dBm
Minimum: – 7.6 dBm
Output Transmit Power:
Typical: -13 dBm
Maximum: -12. dBm
Optical Receive Sensitivity:
Insertion Loss ( Passive:
Normal Mode)
Typical: 1.2 dB
Maximum: 1.8 dB
Insertion Loss ( Passive:
Bypass Mode)
Typical: 1.2 dB
Maximum: 2.1 dB
Power Consumption:
Size:
18.5W
102.2mm x161.9 mm x 40.5 mm (4.02” x 6.37” x 2”)
Wide x Depth x Height
Operating Humidity:
Operating Temperature:
Storage Temperature:
EMC Certifications:
Safety:
0%–90%, non-condensing
0°C – 40°C (32°F – 104°F)
-20°C–65°C (-4°F–149°F)
Class A FCC / CE / BSMI
UL
75 years
MTBF*:
According to Telcordia SR-332 issue 3, environment GB, temperature 40 °C
IS40M40G4BP-QS4 and : LED and Connector Specifications
Green LED per port (Network / Monitor)
Activity : LED will blink.
LEDs:
Page 5
Silicom Ltd. Connectivity Solutions
Link : LED will turn on.
Two LED:
Inline Mode – Green LED.
Non Inline Mode :Bypass, TAP, Disconnect – Yellow (Orange) LED.
HB Status LED
Blinking Green LED – HB is active.
LED is off – HB not active
Network: 2 MPO
Monitor: 2 QSFP+
Connectors:
IS40M40G4BP-QBD (850um/900nm)
Fiber Gigabit Ethernet Technical Specifications – (40GBase-BD) Adapters:
IEEE Standard / Network
topology:
Fiber Gigabit Ethernet, 40GBASE-SR-BiDi (850nm / 900nm)
Data Transfer Rate:
40G per port
Multimode fiber:50um
Cables and Operating
distance:
*50m maximum on OM3 MMF
*75m maximum on OM4 MMF
Theoretical Distance – Defined as half a distance
Typical: 0 dBm
Minimum: -4 dBm
Output Transmit Power:
Maximum: -7.1. dBm at 850nm
Maximum: -7.7. dBm at 900nm
Optical Receive Sensitivity:
Insertion Loss (Passive:
Normal Mode)
Typical: 1.2 dB
Maximum: 2 dB
Insertion Loss (Passive:
Bypass Mode)
Typical: 1.2 dB
Maximum: 2 dB
Power Consumption:
Size:
19W
102.2mm x161.9 mm x 40.5 mm (4.02” x 6.37” x 2”)
Wide x Depth x Height
Operating Humidity:
Operating Temperature:
Storage Temperature:
EMC Certifications:
Safety:
0%–90%, non-condensing
0°C – 40°C (32°F – 104°F)
-20°C–65°C (-4°F–149°F)
Class A / FCC / CE / BSMI
UL
75 years
MTBF*:
According to Telcordia SR-332 issue 3, environment GB, temperature 40 °C
IS40M40G4BP-QBD and : LED and Connector Specifications
Green LED per port (Network / Monitor)
Activity : LED will blink.
Link : LED will turn on.
LEDs:
Two LED:
Inline Mode – Green LED.
Non Inline Mode :Bypass, TAP, Disconnect – Yellow (Orange) LED.
Page 6
Silicom Ltd. Connectivity Solutions
HB Status LED
Blinking Green LED – HB is active.
LED is off – HB not active.
Network: 2 LC
Monitor: 2 QSFP+
Connectors:
IS40M40G4BP-QL4
Fiber 40Gigabit Ethernet Technical Specifications – (40GBase-LR4) Adapters:
IEEE Standard / Network
Fiber Gigabit Ethernet, 40GBase-LR4 (1310nM)
topology:
Data Transfer Rate:
40Gbit/s per port
Single mode fiber:
5000m maximum at 9 um **
**Theoretical Distance – Defined as half a distance
Network ports Cables and
Operating distance:
Typical: 2 dBm
Minimum: – 4 dBm
Output Transmit Power:
Typical: -11 dBm
Maximum: -3.83. dBm
Optical Receive Sensitivity:
Insertion Loss ( Passive:
Normal Mode)
Typical: 1 dB
Maximum: 1.8dB
Insertion Loss ( Passive:
Bypass Mode)
Typical: 1 dB
Maximum: 1.8 dB
Voltage:
Size:
12V +/-5%, 5VSB+/-5%, 5V +/-5%
102.2mm x161.9 mm x 40.5 mm (4.02” x 6.37” x 2”)
Wide x Depth x Height
Operating Humidity:
Operating Temperature:
Storage Temperature:
EMC Certifications:
Safety:
0%–90%, non-condensing
0°C – 40°C (32°F – 104°F)
-20°C–65°C (-4°F–149°F)
Class B FCC / CE / VCCI
UL
75 years
MTBF*:
According to Telcordia SR-332 issue 3, environment GB, temperature 40 °C
IS40M40G4BP-QL4: LED and Connector Specifications
Green LED per port (Network / Monitor)
Activity : LED will blink.
Link : LED will turn on.
Two LED:
LEDs:
Inline Mode – Green LED.
Non Inline Mode :Bypass, TAP, Disconnect – Yellow (Orange) LED.
HB Status LED
Blinking Green LED – HB is active.
LED is off – HB not active
Connectors:
Network: 2 LC
Page 7
Silicom Ltd. Connectivity Solutions
Monitor: 2 QSFP+
IS40M10G8BP-SRD
Dual rate Fiber 10G/1G Ethernet Technical Specifications – (10GBase-SR / 1000Base-SX) Adapters:
IEEE Standard / Network
1000Base-SX, 10GBase-SR (850nM)
topology:
Data Transfer Rate:
20Gbit/s in full duplex mode per port
Multimode fiber:62.5um
16.5m maximum at 62.5 um **
Theoretical Distance – Defined as half a distance as stated by the IEEE 802.3 standard
Cables and Operating
distance:
Typical: -2.5 dBm
Minimum: – 7.3 dBm
Output Transmit Power:
Typical: -14 dBm
Maximum: -11. dBm
Optical Receive Sensitivity:
Insertion Loss ( Passive:
Normal Mode)
Typical: 0.8 dB
Maximum: 1.8 dB
Insertion Loss ( Passive:
Bypass Mode)
Typical: 0.8 dB
Maximum: 1.8 dB
Voltage:
12V +/-5%, 5VSB+/-5%, 5V +/-5%
10.5W
Power Consumption:
102.2mm x161.9 mm x 40.5 mm (4.02” x 6.37” x 2”)
Wide x Depth x Height
Size:
Operating Humidity:
Operating Temperature:
Storage Temperature:
EMC Certifications:
Safety:
0%–90%, non-condensing
0°C – 40°C (32°F – 104°F)
-20°C–65°C (-4°F–149°F)
Class A / FCC / CE / BSMI
CB / UL
48 years
MTBF*:
According to Telcordia SR-332 issue 3, environment GB, temperature 40 °C
IS40M10G8BP-LRD
Dual rate Fiber 10G/1G Ethernet Technical Specifications – (10G Base-LR / 100BaseLX) Adapters:
IEEE Standard / Network
1000Base-LX, 10GBase-LR (1310nM)
topology:
Data Transfer Rate:
20Gbit/s in full duplex mode per port
Netowrk ports Cables and
Operating distance:
Single mode fiber:
5000m maximum at 9 um **
Insertion Loss ( Passive:
Normal Mode)
Typical: 0.8 dB
Maximum: 1.8 dB
Page 8
Silicom Ltd. Connectivity Solutions
Insertion Loss ( Passive:
Bypass Mode)
Typical: 0.8 dB
Maximum: 1.8 dB
Voltage:
12V +/-5%, 5VSB+/-5%, 5V +/-5%
11W
Power Consumption:
102.2mm x161.9 mm x 40.5 mm (4.02” x 6.37” x 2”)
Wide x Depth x Height
Size:
Operating Humidity:
Operating Temperature:
Storage Temperature:
EMC Certifications:
Safety:
0%–90%, non-condensing
0°C – 40°C (32°F – 104°F)
-20°C–65°C (-4°F–149°F)
Class A / FCC / CE / BSMI
CB / UL
48 years
MTBF*:
According to Telcordia SR-332 issue 3, environment GB, temperature 40 °C
IS40M10G8BP-LRd/SRd: LED and Connector Specifications
Green LED per port (Network / Monitor)
Activity : LED will blink.
Link : LED will turn on.
Bi-color LED:
LEDs:
Inline Mode – Green color
Non Inline Mode :Bypass, TAP, Disconnect – Yellow (Orange) color.
HB Status LED
Blinking Green LED – HB is active.
LED is off – HB not active
Network: 4 LC Duplex
Monitor: 4 SFP+
Connectors:
Figure: 1 – Normal Mode Functional Block Diagram
Page 9
Silicom Ltd. Connectivity Solutions
Figure: 2 – Bypass Mode Functional Block Diagram
Figure: 3 – Tap Mode Functional Block Diagram
Figure: 4 – Tap Mode Functional Block Diagram
Page 10
Silicom Ltd. Connectivity Solutions
Order Information
P/N
Description
Notes
IS401U-US-R
Bypass Switch 1U Host System
90-240 VAC Auto-Select, US cable
IS401U-EU-R
IS401U-48
Bypass Switch 1U Host System
Bypass Switch 1U Host System
90-240 VAC Auto-Select, EUcable
Power supply -48VDC
40G Gigabit (SR4) fiber Intelligent Bypass Switch
module
SR4 MMF Single Segment Bypass 40G –
(SR4 on the Network and Monitor ports)
IS40M40G4BP-QS4
IS40M40G4BP-QBD
IS40M40G4BP-QL4
40G Gigabit (SR-BiDi) fiber Intelligent Bypass
Switch module
SR-BiDi MMF Single Segment Bypass 40G –
(SR-BiDi on the Network and Monitor ports)
40G Gigabit (LR4) fiber Intelligent Bypass Switch
module
LR4 SMF Single Segment Bypass 40G –
(LR4 on the Network and Monitor ports)
SR/SX MM Dual Segment Bypass, Dual rate
10G/1G – (SR/SX on the Network and
Monitor ports)
Dual segment 10G/1G Gigabit (SR/SX) fiber
Intelligent Bypass Switch
IS40M10G8BP-SRD
IS40M10G8BP-LRD
LR/LX SM Dual Segment Bypass, Dual rate
10G/1G – (LR/LX on the Network and
Monitor ports)
Dual segment 10G/1G Gigabit (LR/LX) fiber
Intelligent Bypass Switch module
2V4
Page 11
Silicom Ltd. Connectivity Solutions
相关型号:
IS410
Silicon Controlled Rectifier, 10A I(T)RMS, 10000mA I(T), 400V V(DRM), 400V V(RRM), 1 Element, TO-220AB, TO-220, 3 PIN