PE310G4I71L-XR [SILICOM]
Quad Port Fiber SFP 10 Gigabit Ethernet PCI Express Server Adapter;型号: | PE310G4I71L-XR |
厂家: | Silicom |
描述: | Quad Port Fiber SFP 10 Gigabit Ethernet PCI Express Server Adapter PC |
文件: | 总7页 (文件大小:330K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PE310G4I71L Server Adapter
Quad Port Fiber SFP+ 10 Gigabit Ethernet PCI Express Server Adapter Intel® FTXL710BM1 Based
Product Description
Silicom’s 10 Gigabit Ethernet PCI Express server adapters are designed for
Servers and high-end appliances.
The Silicom 10 Gigabit Ethernet PCI Express Server adapters offer simple
integration into any PCI Express X8 to 10Gigabit Networks.
The performance is optimized so that system I/O is not the bottleneck in
high-performance networking applications.
The Silicom 10 Gigabit Ethernet PCI Express server adapters are based on
Intel® XL710 Ethernet controller with fully integrated Gigabit Ethernet Media
Access Control (MAC) and SFI Interface. In addition to managing MAC and PHY Ethernet layer functions, the controller manages
PCI Express packet traffic across its transaction, link, and physical/logical layers. Using hardware acceleration, the controller
offloads tasks from the host, such as TCP/UDP/IP checksum calculations
and TCP segmentation.
Silicom’s 10 Gigabit Ethernet PCI-Express Server adapters are the ideal
solution for implementing multiple network segments, mission-critical high-
powered networking applications and environments within high performance
servers.
Key Features
SFP+ 10Gigabit Ethernet:
10Gigabit Ethernet Adapter with SFP cage support:
-SRD: Fiber 1/10 Gigabit Ethernet 1000Base-SX / 10GBASE-SR:
•
1000BASE-SX with 1G 850nM Small form Factor Pluggable (SFP+)
10GBASE-SR with 10Gigabit 850nM Small form Factor Pluggable (SFP+)
•
-LRD: Fiber 1/10 Gigabit Ethernet 1000Base-LX / 10GBASE-LR:
•
1000BASE-LX with 1G 1310nM Small form Factor Pluggable (SFP+)
10GBASE-LR with 10Gigabit 1310nM Small form Factor Pluggable (SFP+)
•
-SRD: Fiber 1/10 Gigabit Ethernet 1000Base-SX / 10GBASE-SR:
•
10 Gigabit Fiber Ethernet port supports 10GBASE-SR (850nM LAN PHY)
1Gigabit Fiber Ethernet port supports 1000BASE-SX (850nM LAN PHY)
•
Page 1
Silicom Ltd. Connectivity Solutions
•
1/10Gigabit 850nM Small form Factor Pluggable (SFP+)
-LRD: Fiber 1/10 Gigabit Ethernet 1000Base-LX / 10GBASE-LR:
•
10 Gigabit Fiber Ethernet port supports 10GBASE-LR (1310nM LAN PHY)
1Gigabit Fiber Ethernet port supports 1000BASE-LX (1310nM LAN PHY)
1/10Gigabit 1310nM Small form Factor Pluggable (SFP+)
•
•
Performance Features:
•
Support for jumbo frame up to 9.5KB
•
•
•
•
•
•
•
•
Flow control support
Priority Flow Control (draft IEEE 802.1Qbb)
Enhanced Transmission Selection (draft IEEE802.1az)
Statistics management and RMON
802.1q VLAN support
DCB/DCB-X support
Message Signal interrupts (MSI-X)
Storage – Enabling competitive performance with native OS intelligent offload solutions, including NAS, iSCSI and FCoE
Host Interface:
•
PCI Express X8 lanes
•
Support PCI Express Base Specification 3.0 (8GT/sec)
LAN and Virtualization Features:
•
Network Virtualization offloads for VXLAN and NVGRE
•
•
•
•
•
•
Unified Networking Providing a single wire for LAN and storage: NAS (SMB, NFS) and SAN (iSCSI, FCoE)
Virtual Bridging Support – VEPA/802.1Qbg, BPE/802.1Qbh
Physical Functions – Up to 8 per port, up to 16 per device
Support for 128 Virtual Device Queues (VMDq) per port
Hardware Queue Pairs – Up to 1.5K (non-RDMA); up to 256K (RDMA)
Virtualization – Alleviating hypervisor I/O bottlenecks by providing flow separation for Virtual Machines (VMs)
TCP/IP/L2 features:
•
Receive Side Scaling (RSS)
Large Send Offload (LSO)
TCP/UDP/IP/SCTP Checksum Offload
IPV4, IPV6
•
•
•
Page 2
Silicom Ltd. Connectivity Solutions
Technical Specifications
SFP+ 10Gigabit Ethernet Technical Specifications Adapters:
SFP+ (Small Form Factor
Pluggable) supports:
SFI interfaces supports 10GBase-R PCS and 10 Gigabit PMA in order to connect with SFP+ to
10GBase-SR / / 1000Base-SX / 10GBase-LR and SFP+ Direct Attach
10GBase-SR SFP+:
IEEE Standard / Network
topology:
Fiber 10Gigabit Ethernet, 10GBASE-SR (850nM LAN PHY)
10GBase-SR SFP+:
Data Transfer Rate :
10.3125GBd
62.5um, 160MHz/Km 26m
10GBase-SR SFP+:
62.5um, (OM1)200MHz/Km 33m
Cables and Operating distance 50um, 400MHz/Km 66m
Up to
50um, (OM2)500 MHz/Km 82m
50um, (OM3)2000MHz/Km 300m
10GBase-LR SFP+:
IEEE Standard / Network
topology:
Fiber 10Gigabit Ethernet, 10GBASE-LR (1310nM LAN PHY)
10.3125GBd
10GBase-LR SFP+:
Data Transfer Rate:
10GBase-LR SFP+:
Cables and Operating distance Single-Mode: 10000m at 9um
Up to:
10GSFP+Cu :
IEEE Standard / Network
topology:
Copper 10Gigabit Ethernet, 10GSFP+Cu (Direct Attach)
1000Base-SX / 10GBase-SR
SFP+:
Fiber Gigabit Ethernet, 1000Base-SX (850nM LAN PHY)
Fiber 10Gigabit Ethernet, 10GBASE-SR (850nM LAN PHY)
IEEE Standard / Network
topology:
1000Base-SX / 10GBase-SR
SFP+:
10.3125GBd / 1.25GBd
Data Transfer Rate :
10000Base-SX:
62.5um, 160MHz/Km 220m
62.5um, (OM1)200MHz/Km 275m
50um, 400MHz/Km 500m
10000Base-SX / 10GBase-SR
SFP+:
Cables and Operating distance 50um, (OM2)500 MHz/Km 550m
Up to:
50um, (OM3)2000MHz/Km >550m
10GBase-SR:
62.5um, 160MHz/Km 26m
Page 3
Silicom Ltd. Connectivity Solutions
62.5um, (OM1)200MHz/Km 33m
50um, 400MHz/Km 66m
50um, (OM2)500 MHz/Km 82m
50um, (OM3)2000MHz/Km 300m
1000Base-LX / 10GBase-LR
SFP+:
Fiber Gigabit Ethernet, 1000Base-LX (1310nM LAN
IEEE Standard / Network
topology:
Fiber 10Gigabit Ethernet, 10GBASE-LR (1310nM LAN PHY)
1000Base-LX / 10GBase-LR
SFP+:
10.3125GBd / 1.25GBd
Data Transfer Rate :
1000Base-LX / 10GBase-LR
SFP+:
10000Base-LX:
Single-Mode: 5000m at 9um
Cables and Operating distance 10GBase-LR:
Up to:
Single-Mode: 10000m at 9um
1000Base-T SFP:
IEEE Standard / Network
topology:
1000BASE-T Ethernet
-SRD: Fiber 1000BASE-SX / 10GBASE-SR Technical Specifications:
Typical: -2.39 dBm
Optical Output Power (1G):
Minimum: -9.5 dBm
Optical Receive Sensitivity
(1G):
Typical: -14.32 dBm
Maximum: -17 dBm
Maximum Input Power (1G):
Output Transmit Power (10G):
Maximum: +0.5dBm
Typical: -2.39 dBm
Minimum: -5 dBm
Optical Receive Sensitivity
(10G):
Typical: -14.32 dBm
Maximum: -11.1 dBm
Maximum Input Power (10G):
Maximum: +0.5dBm
-LRD: Fiber 1000BASE-LX / 10GBASE-LR Technical Specifications:
Typical: -1.77 dBm
Optical Output Power (1G):
Minimum: -11 dBm
Optical Receive Sensitivity
(1G):
Typical: -17 dBm
Maximum: -19 dBm
Maximum Input Power (1G):
Output Transmit Power (10G):
Optical Receive Sensitivity
Maximum: +0.5dBm
Typical: -1.77 dBm
Minimum: -8.2 dBm
Typical: -17 dBm
Page 4
Silicom Ltd. Connectivity Solutions
(10G):
Maximum: -12.5 dBm
Maximum: +0.5dBm
Maximum Input Power (10G):
Operating Systems Support
Operating system support:
General Technical Specifications
Windows
Linux
FreeBSD
VMware
Interface Standard:
Board Size:
PCI-Express Base Specification Revision 3.0 ( 8 GTs)
Low profile short add-in card: 165.15mm X 64.39mm (6.502”X 2.535”)
PCI Express Card Type:
On Board Connector Voltage
PCI Connector:
Controller:
X8 Lane
+12V +/-8%
X8 Lane
Intel® FTXL710BM1
Metal Bracket
240 g
Holder:
Weight:
6W, 0.5A at 12V: Typical all ports operate at 10Gb/s,
6W, 0.5A at 12V: Typical No link at all ports
Power Consumption (SR):
Power Consumption (LR):
6.24W, 0.52A at 12V: Typical all ports operate at 10Gb/s, 6.24W, 0.52A at 12V: Typical No link
at all ports
Operating Temperature:
Air Flow Requirements:
Storage:
0°C – 45°C (32°F – 113°F)
200 ft./min
-40°C–65°C (-40°F–149°F)
FCC Part 15, Subpart B Class A
Conducted Emissions
Radiated Emissions
CE EN 55022: 1998 Class A Amendments A1: 2000; A2: 2003
Conducted Emissions
Radiated Emissions
CE EN 55024: 1998 Amendements A1: 2000; A2: 2003
Immunity for ITE Amendment A1: 2001
CE EN 61000-3-2 2000, Class A
Harmonic Current Emissions
EMC Certifications:
CE EN 61000 3-3 1995, Amendement A1: 2001
Voltage Fluctuations and Flicker
CE IEC 6100-4-2: 1995
ESD Air Discharge 8kV. Contact Discharge 4kV.
CE IEC 6100-4-3:1995
Page 5
Silicom Ltd. Connectivity Solutions
Radiated Immunity (80-1000Mhz), 3V/m 80% A.M. by 1kHz
CE IEC 6100-4-4:1995
EFT/B: Immunity to electrical fast transients 1kV Power
Leads, 0.5Kv Signals Leads
CE IEC 6100-4-5:1995
Immunity to conductive surges COM Mode; 2kV,
Dif. Mode 1kV
CE IEC 6100-4-6:1996
Conducted immunity (0.15-80 MHz) 3VRMS 80% A.M.
By 1kHz
CE IEC 6100-4-11:1994
Voltage Dips and Short Interruptions
V reduce >95%, 30% >95% Duration 0.5per, 25per, 250per
36 years
MTBF*:
LEDs
* According to Telcordia SR-332 Issue 2. Environmental condition – GB (Ground, Fixed, and
Controlled). Ambient temperature 40°C
(2) LEDs per port
Upper LED : Link Speed:
Turns on Blue 10G Link.
Turns on Yellow 1G Link
Lower LED: Link/Act :
Turns on link (Green),
Blinks on activity (Green)
LEDs:
LEDs are located on the PCB, visible via holes in the metal bracket. Each Green Link/Act and
LED and Blue Link Speed LED is located above its own SFP connector port by light pipes
LEDs location:
Connectors:
(4) SFP+ cage
Order Information
P/N
Description
Notes
X8 Gen3 , Low Profile, Based on Intel® XL710,
Support Direct Attached Copper cable, Support
Silicom SFP+ approved transceiver. RoHS
compliant
Quad Port SFP+ 10 Gigabit Ethernet PCI Express
Server Adapter
PE310G4i71L-XR
PE310G4i71L-SRD
X8 Gen3, Based on Intel® XL710, Low-profile,
on board support for Fiber SX/SR, RoHS
compliant
Quad Port Fiber (SX/SR) 1/10 Gigabit Ethernet PCI
Express Server Adapter
X8 Gen3, Based on Intel® XL710, Low-profile,
on board support for Fiber LX/LR, RoHS
compliant
Quad Port Fiber (SX/SR) 1/10 Gigabit Ethernet PCI
Express Server Adapter
PE310G4i71L-LRD
Page 6
Silicom Ltd. Connectivity Solutions
X8 Gen3 , Low Profile, with lower I/O metal
bracket opening, Based on Intel® XL710,
Support Direct Attached Copper cable, Support
Silicom SFP+ approved transceiver. RoHS
compliant
Quad Port SFP+ 10 Gigabit Ethernet PCI Express
Server Adapter
PE310G4i71LBEU-XR
E – PXE Boot,
U – support UEFIx64
(blank) – PXE and UEFI disabled
X8 Gen3, Low Profile, with lower I/O metal
Quad Port Fiber (SX/SR) 1/10 Gigabit Ethernet PCI bracket opening, Based on Intel® XL710, Low-
PE310G4i71LB-SRD
PE310G4i71LB-LRD
Express Server Adapter
profile, on board support for Fiber SX/SR,
RoHS compliant
X8 Gen3, Low Profile, with lower I/O metal
Quad Port Fiber (SX/SR) 1/10 Gigabit Ethernet PCI bracket opening, Based on Intel® XL710, Low-
Express Server Adapter
profile, on board support for Fiber LX/LR, RoHS
compliant
8 Gen3, Low Profile, with lower I/O metal
bracket opening, Based on Intel® XL710, Low-
profile
Quad Port Fiber 1/10 Gigabit Ethernet PCI Express
Server Adapter
PE310G4i71LB-XR
Support Direct Attached Copper cable, Support
Silicom SFP+ approved transceiver. RoHS
compliant
Order information: Model P/N -LP /
-LP: Assemble Low Profile Metal Bracket
2V5
Page 7
Silicom Ltd. Connectivity Solutions
相关型号:
PE311-12
SMA Male to Push-On SMA Male Precision Cable 12 Inch Length Using 160 Series Coax, RoHS
PASTERNACK
PE311-120
SMA Male to Push-On SMA Male Precision Cable 120 Inch Length Using 160 Series Coax, RoHS
PASTERNACK
PE311-24
SMA Male to Push-On SMA Male Precision Cable 24 Inch Length Using 160 Series Coax, RoHS
PASTERNACK
PE311-36
SMA Male to Push-On SMA Male Precision Cable 36 Inch Length Using 160 Series Coax, RoHS
PASTERNACK
©2020 ICPDF网 联系我们和版权申明