UG252: ZigBee Lighting Reference
Design Demo Board Kit User's Guide
(RD-0085-0401, RD-0035-0601)
The Silicon Labs ZigBee Lighting Reference Design modules and demo boards are de-
KEY POINTS
signed to demonstrate the functionality of ZigBee lighting applications with EFR32MG
or EM3585 ZigBee chipsets. This document contains instructions and guidelines for the
• ZigBee demonstration
following: a quick-start demonstration and next steps, system overview and operation,
hardware and firmware considerations, and engineering and manufacturing testing.
• System Overview and Operation
• Hardware and Firmware Considerations
• Engineering and Manufacturing Testing
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Introduction
1. Introduction
The Silicon Labs Zigbee Lighting Reference Design modules and demonstration boards are designed to demonstrate ZigBee lighting
applications with EFR32MG or EM3585 ZigBee chipsets. The modules are preprogrammed for an "out of the box" demonstration using
the demonstration board shown in the figure below. The modules can also be directly integrated into a connected lighting application as
described in 6.3 Module Hardware Integration Guidelines. An example of such an application is shown in Figure 1.2 below. Hardware
design files and firmware application source code are available for all items in the kit.
This document will address quickstart for demonstration and next steps, system overview and operation, hardware and firmware con-
siderations, and engineering and manufacturing test.
Lighting Module
Demonstration Board
LEDs and diffuser
Figure 1.1. ZigBee Lighting Reference Design module and demonstration board
HV Supply
AC Mains
High
Voltage
LED
Power
Supply
3.3V
3.3V
PWMs
Supply
Driver
Lighting
Reference
Design
Figure 1.2. Connected Lighting Application Example
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 1
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Quick Start Demonstration
2. Quick Start Demonstration
The Lighting Reference Design demo board can be demonstrated as part of a ZigBee network. All ZigBee networks must have one
device, such as a gateway, that plays the role of coordinator and allows commissioning of new devices on the network. Other ZigBee
devices may be present in order to evaluate interoperability with the lighting reference design. An example Zigbee network is shown in
the figure below.
Development computer
Other ZigBee Devices
USB
WSTK
10-pin
ZigBee
ribbon cable
Mesh Network
WSTK Debug
Adapter Board
ZigBee Gateway
ZigBee Lighting Reference Design
and Demo Board
Figure 2.1. Example ZigBee network used for demonstration and evaluation
A video showing the quickstart demonstration is available at https://youtu.be/qlhowiLyfCI.
Verify the Kit Contents
Make sure the following items are part of your ZigBee Lighting Reference Design kit.
1. ZigBee Lighting Reference Design module and demo board assembled hardware
2. micro-USB cable for power
3. Quickstart card to obtain the latest reference design collateral
Set Up an HA 1.2 ZigBee Gateway
Silicon Labs offers RD-0002-0201 or RD-0001-0201 ZigBee gateways (sold separately) for the purpose of evaluating the ZigBee Light-
ing Demo Board. However, a commercially available Home Automation (HA) 1.2 compliant gateway that supports level lighting with
device profile ID=0x0100, 0x0101 and 0x0102 may work for this purpose provided that the gateway does not require device whitelisting
or optional clusters not implemented in the reference design firmware of the ZigBee lighting module. See the section titled Ecosystem
Considerations for more information.
Supply Power to the ZigBee Lighting Demo Board
1. Use a cable such as the one provided in the kit to connect the micro-USB header on the demo board to a standard USB port or
+5VDC power supply.
a. micro-USB header is labelled J3 on RD-0085-0401
b. micro-USB header is labelled J4 on RD-0035-0601
2. The demo board is powered when the supply indicator LED is lit.
a. Supply indicator is green LED D11 on RD-0085-0401
b. Supply indicator is red LED D4 on RD-0035-0601
Join the Zigbee Lighting Demo Board to the ZigBee Network
1. Follow the directions provided with the ZigBee gateway to enable new devices to join the network.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 2
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Quick Start Demonstration
2. Press the demo board power supply interrupt button rapidly 10 times to begin the network join procedure. This mimics the effect of
power cycling a light bulb 10 times.
a. Use switch S1, VDD OFF, on RD-0085-0401
b. Use switch S1, 3V3 OFF, on RD-0035-0601
3. The demo board has joined the ZigBee network when LEDS D1-D5 flash 10 times.
4. On RD-0085-0401 network status is also indicated by the green network status LED, D6. Solid green color means it is on a net-
work. LED off means the bulb is not on a network. Note that the slider switch S2 needs to be set towards "NETWORK STATUS" to
enable this feature.
Demonstrate ZigBee Lighting Control
1. Use the gateway interface to turn LEDs D1, D2, and D3-D5 (RD-0085-0401 only) on and off.
2. Set the intensity (also called the brightness or dimming level).
3. Set the color of D1.
4. Set the color temperature.
a. On RD-0035-0601, color temperature is produced using RGB LED D1.
b. On RD-0085-0401, color temperature is produced using RGB LED D1 when the module is loaded with the HaColorControl-
Light example application or using color-temperature tuned LEDs D2, D3, D4 and D5 when the module is loaded with HaCo-
lorTempLight example application.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 3
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Recommended Next Steps
3. Recommended Next Steps
A video showing the recommended next steps is available at http://www.silabs.com/products/wireless/Pages/zigbee-connected-light-
ing.aspx
Evaluate the Demo Board
The ZigBee Lighting Reference Design has been designed to support common ZigBee lighting application requirements. Typical areas
for evaluation include:
1. PWM frequency and duty cycles
2. RF performance such as channel power and range
3. ZigBee network behavior such as network join and leave
The remainder of this document covers these topics in detail.
Evaluate the Firmware
If firmware modification is necessary:
1. Visit the ZigBee getting started page and order a development kit: http://www.silabs.com/zigbeetraining
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 4
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Overview
4. Overview
The Silicon Labs Lighting Reference Design demo board facilitates the evaluation of the ZigBee Lighting Reference Design module and
the customization of lighting application firmware. In addition to programming and debug access, the demo board has a number of fea-
tures specifically useful for lighting applications such as RGB and Color-Temperature LEDs, a power-interrupt button to mimic switching
of the mains supply, and PWM test points that can be wired directly into a light engine.
4.1 Part Numbers
The part numbers convention is RD-XXXX-YYYY, where:
RD
Reference Design
XXXX
YYYY
Reference Design Number
Reference Design Component
This document will call out the reference design number (i.e., RD-XXXX) when describing the complete design and the reference de-
sign component (i.e., RD-XXXX-YYYY) when describing a specific component.
The table below provides a description and PCB marking for each part number. Note that in some cases there is not sufficient space on
the PCB and an internal "IST" marking appears on the PCB instead of the "RD" part number.
Table 4.1. Part Numbers and Descriptions
Part Number
PCB Marking
Description
RD-0085-0401
N/A
ZigBee Lighting Reference Design with
EFR32 Demo Board Kit
N/A
IST-A0050
IST-A0085
ZigBee Lighting Demo Board
RD-0085-0101
ZigBee Lighting Reference Design with
EFR32 - module only
RD-0035-0601
RD-0035-0501
RD-0035-0101
N/A
ZigBee Lighting Reference Design with
EM3585 Demo Board Kit
RD-0035-0501 IST-A21
IST-A35
ZigBee Lighting Reference Design with
EM3585 Demo Board
ZigBee Lighting Reference Design with
EM3585
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 5
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Overview
4.2 Features and Benefits of the RD-0085 Demo Board
Lighting Reference Design Module
The reference design kits include an IST-A0085 lighting module. This module is pre-programmed with a ZigBee lighting application.
Adapter Board
Each reference design module is mounted on an adapter board to provide connectivity to the ZigBee lighting demo board as well as the
Silicon Labs Wireless STK. The adapter board and lighting demo board also have mounted EEPROMs with board-specific information
stored. This allows Silicon Labs software to easily detect the connected hardware and configure themselves to show relevant informa-
tion.
Lighting Demo Board
The ZigBee lighting demo board provides for the evaluation of the ZigBee lighting reference design module. Features are listed in the
table below.
Demo Board Feature
Benefit
Low and high temperature white LEDs, tri-color RGB LED
Network status LED
Simulate LED lighting scenarios
LED ON means on a ZigBee network. LED OFF means not on a
ZigBee network.
Micro-USB connector
Provides power
10-pin mini-Simplicity compatible connector
Power down button
Facilitates programming, debug, and packet trace
Mimics momentary mains switch
Demo board power indication
Green power indicator LED
SW1 brightness switch
Selects between High and Low LED brightness
SW2 network status LED switch
Selects between routing PWM output to Network Status LED or
TP9. Can be used to turn off the LED or select GPIO for different
purpose.
SW3 power switch
Mimics mains power switch
LiPo battery connector
Provides additional power options
Note: The single-cell LiPo battery begins charging with power supplied through the micro-USB connector.
Stackup view
RGB LEDs
White LEDs
microUSB connector
(pwr only)
RD-0085-0101 module
IST-A0088 adapter board
IST-A0050 Lighting Demo Board
Power-down button
Figure 4.1. Complete RD-0085 ZigBee Lighting Reference Design Board
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 6
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Overview
4.3 Features and Benefits of the RD-0035 Demo Board
Lighting Reference Design Module
The reference design kits include an RD-0035-0101 lighting module. These modules are pre-programmed with a ZigBee lighting appli-
cation.
Adapter Board
Each reference design module is mounted on an adapter board to provide connectivity to the ZigBee lighting demo board.
Lighting Demo Board
The ZigBee lighting demo board provides for the evaluation of the ZigBee lighting reference design module, including
Demo Board Feature
Benefit
White LED, tri-color RGB LED
10-pin ISA3 compatible connector
Power down button
Simulates LED lighting scenarios
Facilitates ZigBee wireless packet debugging
Eases network commissioning (join/leave)
Demo board power indication
Provides dual-power options
Red power indicator LED
Micro-USB and LiPO battery connectors
Note: The single-cell LiPo battery begins charging with power supplied through the micro-USB connector.
microUSB connector (pwr only)
RGB LEDs
White LED
Exploded view of stackup
RD-0035-0101
Adapter board
Lighting Demo Board
Power-down button
Figure 4.2. Complete RD-0035 ZigBee Lighting Reference Design Board
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 7
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Overview
4.4 Features of the RD-0085 and RD-0035 Zigbee Lighting Reference Designs Modules
ZigBee Lighting Reference Design Hardware Features
RD-0085-0101
RD-0035-0101
32-bit ARM® Cortex-M4
38.4 MHz
32-bit ARM® Cortex-M3
24 MHz
Processor
Crystal frequency
Encryption Accelerators
Advanced Crypto Accelerators
Peripherals
AES128
SHA-1, SHA-2, ECC
—
ADC, UART
512 kB
4
ADC, UART, SPI, TWI
Flash size
768 kB
6
Number of PWMs
MAC/PHY
2.4 GHz IEEE 802.15.4
Included
Packet trace
Antenna
PCB, Inverted F
2.3V - 3.6V
Voltage range
Temperature range
Transmit power
FCC certification
-40C to 125C
+20 dBm
Pre-certified FCC Part 15
ZigBee Lighting Reference Design Firmware Features
Application firmware is available both as precompiled binaries and as source via the EmberZNet PRO stack. Firmware can be updated
either via a hardwired debugger connection or other-the-air (OTA) using an OTA-enabled gateway.
The following clusters are used in the reference design application.
Cluster Name
Basic
Cluster Hex Value
0x0000
Identify
0x0003
Groups
0x0004
Scenes
0x0005
On/Off
0x0006
Level
0x0008
Over-the-Air Boot Loading
Color Control
Diagnostics
0x0019
0x0030
0x0B05
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 8
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Operation Details for the Zigbee Lighting Reference Designs
5. Operation Details for the Zigbee Lighting Reference Designs
5.1 Zigbee Network Behavior
This section will describe the various operational states a powered lighting reference design is able to occupy as it joins and leaves a
ZigBee network. The input mechanisms for operation utilize a physical power-cycling methodology which can either be employed by
externally disabling and enabling the demo board's power supply or by utilizing button S1 where a button assertion equates to powering
off and releasing equates to power up. The white and tri-color LEDs operate as output signalling information as the demo board traver-
ses or occupies a functional state. Refer to the figure below for a pictorial representation of this process.
4 power cycles or
Identify command
from gateway
IDENTIFY MODE
Indicated by
steady blinking
mode times out
5-9 power cycles
ON NETWORK
REJOIN NETWORK
(no visual indication)
Controlled via gateway
mode times out
or
new parent found
10 power cycles
NETWORK JOIN
10 rapid blinks indicate
a successful join
joinable network found
no joinable
network found
OFF NETWORK
LEAVE NETWORK
ACTIVE NTWK SEARCH
Behaves like a
traditional bulb
lasts up to 2 minutes
(no visual indication)
3 slow blinks indicate
successful network leave
any number
of power cycles
Figure 5.1. Device Operation State Diagram
First Time Demo Board Power-Up
After the hardware has been powered up for the first time, the device will be in a factory default mode and be placed in the ACTIVE
NTWK SEARCH state.
OFF NETWORK State
This state is a condition where the demo board is not connected to a network and is not aggressively searching for a network. To leave
this state and to enter the ACTIVE NTWK SEARCH state, the power to the board needs to be cycled at least one time (most easily
accomplished by pressing button S1). The device does continue to perform infrequent searches for networks while in the OFF NET-
WORK state.
The white/tri-color LEDs on the board will operate like a conventional non-connected light when in this state.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 9
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Operation Details for the Zigbee Lighting Reference Designs
ACTIVE NTWK SEARCH State
This state is a condition where the demo board is actively searching for a network but has not joined a network. This operation for
actively searching for a network will remain for approximately up to two minutes. If no network is found by that time limit, the demo
board will enter into the OFF NETWORK state. If a network is found it will enter the NETWORK JOIN state. Power-cycling while in this
state will reset the timer and keep the demo board in this state for two additional minutes. If a network is found it will leave this state and
enter the NETWORK JOIN state.
The white/tri-color LEDs on the board will operate like a conventional non-connected light while in this state.
NETWORK JOIN State
After a demo board leaves the ACTIVE NTWK SEARCH state and enters this state, the white/tri-color LEDs will flash 10 times to indi-
cate successfully finding and joining a network. This state is transitory as the light moves immediately to the ON NETWORK state once
the LEDS complete their flash sequence. Power-cycling at this time will only impair the 10 LED flashes, but not prevent entry into the
ON NETWORK STATE once the power is reapplied.
ON-NETWORK State
This state is a condition where the demo board is connected to a ZigBee HA 1.2 network and is not searching for a network. While in
this state, the white/tri-color LEDs illumination on the demo board will correspond to commands the demo boards receive from the Zig-
Bee network. This state contains multiple entry and exit paths depending on various factors such as number power-cycles received
within a short time period of a few consecutive seconds.
If the power to the demo board is removed for long periods of time, the demo board will immediately rejoin its original joined network
when power becomes available and will not seek other networks, unless the user forces it to leave its joined network as will be descri-
bed within this section.
If the demo board is power-cycled four times, the demo board will temporarily enter the IDENTIFY state while remaining on its joined
network.
If the demo board is power-cycled from five to nine times, the demo board will temporarily enter the NETWORK STATUS state while
remaining on its joined network.
If the demo board is power-cycled ten times OR if the demo board receives a leave network command, the demo board will enter the
LEAVE NETWORK state.
IDENTIFY State
The purpose of this state is to help an installer (or user) identify which bulb is being communicated to by visually flashing in a specified
pattern so this person can locate the targeted light. After a demo board leaves the ON-NETWORK state and enters this state, the white/
tri-color LEDs will flash at a 0.5 Hz rate. This state is temporary and will return the demo board into the ON NETWORK state once the
state's timer reaches its time limit or if power is cycled at least once to the demo board. There are two ways to enter this mode depend-
ing on the intended application.
The first method is done locally to the bulb by power cycling it 4 times. The main purpose of this method is to support EZ Mode commis-
sioning, whereby the light becomes discoverable by other devices as a candidate for pairing. The bulb will blink at 0.5 Hz until the Iden-
tify Mode times out after 3 minutes.
The second method is done remotely by sending an Identify command from a gateway. The main purpose of this method is to allow an
installer to visually locate the bulb in question. The bulb will blink at 0.5 Hz until the Identify Mode for the duration is requested by the
gateway.
NETWORK STATUS State
The purpose of this state is to help an installer (or user) identify if the light is successfully connected to a network. After a demo board
leaves the ON-NETWORK state and enters this state, the white/tri-color LEDS will flash at a 2 Hz rate. This state is temporary and will
return the demo board into the ON NETWORK state once the state's timer reaches its time limit or if power is cycled at least once to the
demo board.
LEAVE NETWORK State
After a demo board leaves the ON NETWORK state and enters this state, the demo board will leave the joined network and will indicate
this process is in action by slow flashing the white/tri-color LEDS three times at a 0.5 Hz rate. This state is termporary and will place the
demo board into the ACTIVE NTWK SEARCH sstate once the LEDs complete their flash sequence. Power-cycling will only impair the
slow LED flashes but not prevent entry into the ACTIVE NTWK SEARCH state once the power is reapplied.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 10
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Hardware Details for the Zigbee Lighting Reference Design
6. Hardware Details for the Zigbee Lighting Reference Design
This section describes the key aspects of the reference design.
6.1 Zigbee Lighting Reference Design RD-0085
This section describes the key hardware specifics of the RD-0085 module.
Key Highlights
• EFR32MG ZigBee PRO radio with stacked flash
• Two-layer 0.062" printed circuit board with all components on primary side
• 8-pin 0.050" application header with VDD, GND, and six PWM output pins
• 10-pin debug header with packet trace functionality
EFR32MG
Debug,
Packet
Trace
EmberZNET
PRO ZigBee
Stack
XTAL
Lighting
Application
Firmware
Lighting
PWM
Header
PCB
Trace
Antenna
PWM
Generation
Figure 6.1. Module Block Diagram
Integrated PCB antenna
2.60 mm
EFR32MG1P732
F256IM32
D1 D2
D3 D4
D5 D6
D7 D8
D9 D10
Debug port
1
2 3 4 5 6 7 8
1.27 mm
Application pins
1.92 mm
1.92 mm
14 mm
Figure 6.2. Module Photo, Pin Numbering, and Dimensions
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 11
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Hardware Details for the Zigbee Lighting Reference Design
Table 6.1. Lighting PWM Header
Pin #
Pin Name
Preconfigured Pin Connec-
tion
Pin Function
1
2
3
VDD
GND
PB14
3.3V Supply Voltage
Ground
PWM - Timer 0, Channel 0
PWM - Timer 0, Channel 1
White Light (Higher Tempera-
ture)
4
PB15
White Light (Lower Tempera-
ture)
5
6
7
8
PB11
PC10
PD15
PC11
PWM - Timer 0, Channel 2
PWM - Timer 1, Channel 0
PWM - Timer 1, Channel 1
PWM - Timer 1, Channel 2
Network Status
Red Light
Green Light
Blue Light
Note: Additional pin functions require custom firmware. Refer to the data sheet for available functions.
Table 6.2. Debug Port
Pin #
D1
Pin Name
VDD
Pin Functions
VDD
Description
Supply Voltage
D2
GND
GND
Ground
D3
RESETn
PA1
RESETn
MCU Reset
D4
USART_RX
USART_TX
SW_O/TDO
SW_DIO
USART RX
D5
PA0
USART TX
D6
PF2
Serial Wire Viewer Output
Serial Wire Data Input/Output
Serial Wire Clock
Packet Trace Enable
Packet Trace Data
D7
PF1
D8
PF0
SW_CLK
PTI_SYNC
PTI_DATA
D9
PB13
PB12
D10
Note: The debug connector is compatible with the mini-simplicity packet trace port connector, connected from the top side.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 12
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Hardware Details for the Zigbee Lighting Reference Design
6.2 Zigbee Lighting Reference Design RD-0035
This section describes the key hardware specifics of the RD-0035 module.
Key Highlights
• EM3585 ZigBee Pro radio with embedded flash
• SKY66019 power amplifier (PA)
• Four-layer 0.062" printed circuit board with all components on primary side
• 6-pin 0.050" application header with VDD, GND, and four PWM output pins
• 10-pin debug header with packet trace functionality
EM3585
Debug,
Packet
Trace
EmberZNET
PRO ZigBee
Stack
SKY66109
FEM
XTAL
Lighting
Application
Firmware
Lighting
PWM
Header
PCB
Trace
Antenna
PWM
Generation
Figure 6.3. Module Block Diagram
Integrated PCB antenna
FEM
EM3585
Debug and
D10 D8 D6 D4 D2
Packet Trace
port
D9 D7 D5 D3 D1
1
2
3
4 5 6
2.0 mm
14 mm
Application pins
Figure 6.4. Module Photo, Pin Numbering, and Dimensions
Connector Pin Assignments
Table 6.3. Lighting PWM Header
Function
PIN #
Pin Name
Description
Preconfigured
Additional
1
2
GND
VDD
Ground
3.3 Supply
Voltage
3
PB1
PWM1
SC1MISO
SC1MOSI
SC1TXD
SC1SDA
GPIO PB1,
SPI1 MISO,
SPI1 MOSI,
UART1 TX
Out, I2C1 Da-
ta, PWM1 Out-
put
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 13
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Hardware Details for the Zigbee Lighting Reference Design
PIN #
Pin Name
Function
Description
4
PB2
PWM2
SC1MISO
SC1MOSI
SC1RXD
SC1SCL
GPIO PB2,
SPI1 MISO,
SPI1 MOSI,
UART1 RX In,
I2C1 Clock
PWM2 Output
5
6
PB3
PB4
PWM3
PWM4
SC1SCLK
SC1nCTS
SC1nRTS
GPIO PB3,
SPI1 Clock,
UART1 Clear
to Send,
PWM3 Output
SC1nSSEL
GPIO PB4,
SPI1 Chip Se-
lect, UART1
Request to
Send, PWM4
Output
Note: Secondary pin functions require custom firmware.
Table 6.4. Packet Trace Port
Pin #
D1
Pin Name
Pin Functions
Description
VBRD
PC2
Supply Voltage
JTAG Data Out, Serial Wire Out
JTAG Reset
D2
JTDO/SWO
nJRST
D3
PC0
D4
PC3
JTDI
JTAG Data In
D5
GND
SWCLK
PC4
Ground
D6
JTCK/SWCLK
JTMS/SWDIO
JTAG Clock, Serial Wire Clock
D7
JTAG Mode Select, Serial Wire
Data In/Out
D8
D9
nRESET
PA4
EM3xxx Reset
Packet Trace Enable
Packet Trace Data
PTF
PTD
D10
PAS
Note: The debug connector is compatible with the ISA3 packet trace port connector when placed on the bottom side of the PCB.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 14
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Hardware Details for the Zigbee Lighting Reference Design
6.3 Module Hardware Integration Guidelines
This section contains guidelines on how to integrate the lighting module in a custom application. Schematically, the integration is
straightforward: the user only needs to provide power and ground hookups and ensure that the PWM signals are wired to the appropri-
ate locations in the light engine. Layout and mechanical design can be more involved, so tips are provided below.
The Power, Ground and PWM signals are not intended to carry high-frequency information and can therefore be handled using stand-
ard best practices of PCB design.
Placing any type of material near the RF section and antenna, particularly metals and strong dielectrics, will have a big effect on anten-
na performance and on spurious emissions. The region nearest the antenna within 1 wavelength, which at 2.4 GHz is approximately
12.5 cm or 5 inches, is known as the near-field region. Ideally no foreign materials should be introduced in this region.
In practice, lightbulbs are not large enough to allow for that keep-out. However, we have observed that keeping metals at least 2.5 cm
away from the antenna tends to produce good results. Metal that is part of a radiating ground plane is not harmful and may often be
extended without issue, although it does have an effect on antenna matching. This generally includes ground planes under the module
(but not under the antenna).
The following images show the most common layouts as an example of which layout practices are suggested
Horizontal Mounting Guidelines
Either hang the antenna off the PCB edge (right figure) or remove the PCB ground plane beneath the antenna and extending beyond
the module along the edge (left figure). Both RD-0085 and RD-0035 can be mounted using a through-hole header. In addition, RD-0085
has castellation pins around the perimeter that allow it to be used in a standard SMT flow without the need for an intervening header.
PCB with ground plane partially removed
PCB with ground plane
The following connectors are recommended for horizontal mounting applications.
Through-hold mount
Surface mount
RD-0085-0101
RD-0035-0101
FTS-108-01-F-S (Samtec)
TMM-106-01-G-S (Samtec)
Solder directly to castellation pins
N/A
Vertical Mounting Guidelines
The lighting reference design modules can also be mounted vertically using a right angle connector. There is no inherent advantage in
this arrangement other than to provide additional flexibility in the mechanical design of the host application.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 15
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Hardware Details for the Zigbee Lighting Reference Design
The following right-angle connectors are recommended for vertical mounting applications.
Through-hold mount
TM-108-01-F-S-RA (Samtec)
TMM-106-01-G-S (Samtec)
Surface mount
RD-0085-0101
RD-0035-0101
N/A
N/A
Connector Information
The following links provide further information about recommended connectors:
http://suddendocs.samtec.com/prints/fts-1xx-xx-x-sx-mkt.pdf
http://suddendocs.samtec.com/prints/tms-1xx-xx-xx-x-xx-xxx-mkt.pdf
http://cloud.samtec.com/Prints/TMM-1XX-XX-XX-X-XX-XXX-MKT1.pdf
http://cloud.samtec.com/Prints/TMM-STH.PDF
http://cloud.samtec.com/Prints/TMM-1XX-XX-XX-X-RA-XXX-MKT.pdf
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 16
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Hardware Details for the Zigbee Lighting Reference Design
6.4 Module Hardware Modification Guidelines
Modification of the reference design module is discouraged, however we recognize that some users may require slight changes in order
to satisfy mechanical requirements in specific installations.
Modify With Care
While any modification is discouraged, those listed here should have less effect on RF performance.
• Changing the type of connector
• Pitch, spacing, rows, size
• Changing from castellation to through hole, and vice versa
• Selecting different GPIO pins
• Pins close to the RF Frontend should not be modified
Avoid Modification
All changes listed here may have serious impacts on module performance.
• Modifying the spacing near any IC, especially near the RF ports
• Modifying the layout of RF bypass capaciitors
• Changing the PCB Antenna Length
• Altering any part of the Ground Pour Area
• Changing the number of metal layers
Avoid modifying
Modify with care
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 17
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Firmware Details for the ZigBee Lighting Reference Design
7. Firmware Details for the ZigBee Lighting Reference Design
The purpose of this section is to describe the lighting reference design application firmware.
7.1 Obtaining the Firmware Application
The firmware application in pre-compiled binary form is available for download from http://www.silabs.com/yyyNEED REAL LINK
HERE. The firmware application source code is available as part of Ember ZNetPRO, which is available to registered users of a devel-
opment kit. For more information, visit the ZigBee Getting Started page: http://www.silabs.com/products/wireless/zigbee/Pages/zigbee-
getting-started.aspx
7.2 Programming the RD-0085 Lighting Reference Design
The reference design provides two methods to re-program the demo board:
• Using a WSTK debugger and mini-simplicity adapter board to upload an .s37, .bin or .hex image
• Using the over-the-air (OTA) upgrade feature with an .ota image file.
Board Header Reprogramming
The demo board can be reprogrammed with an available .s37 or .hex file and a WSTK programmer. Please refer to Application Note
AN958 for more information on how to successfully program the demo board with the WSTK programmer and mini-simplicity adapter
board. The debug connector on the demo board is the J2 header. Note the orientation of the connector where the keyed side of the
connector corresponds to the key marking found with the silkscreen drawing surrounding the J2 header.
Over-the-Air Programming
The demo board can be reprogrammed with an available .ota file and a device that can perform OTA upgrades such as the
RD-0002-0101 ZigBee USB Gateway Kit supported by Silicon Labs. Refer to the gateway documentation for more information on how
to reprogram via OTA upgrade.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 18
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Firmware Details for the ZigBee Lighting Reference Design
7.3 Programming the RD-0035 Lighting Reference Design
The reference design provides two methods to reprogram the demo board:
• Using the ISA3 debugger with an .s37 or .hex image file
• Using the over-the-air (OTA) upgrade feature with an .ota image file
Board Header Reprogramming
The demo board can be reprogrammed with an available .s37 or .hex file and an ISA3 programmer. Please refer to the Silicon Labs
UG110 User's Guide on ISA3 for more information on how to successfully program the demo board with the ISA3 programmer. The
ISA3 connector on the demo board is the J3 header.
Note: The orientation of the connector where the keyed side of the connector corresponds to the ISA3 key marking is found with the
silkscreen drawing surrounding the J3 header.
Figure 7.1. Demo Board's ISA3 Header
Over-the-Air Reprogramming
The demo board can be reprogrammed with an available .ota file and a device that can perform OTA upgrades such as the
RD-0002-0101 ZigBee USB Gateway Kit supported by Silicon Labs. Refer to the gateway documentation for more information on how
to reprogram via OTA upgrade.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 19
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Firmware Details for the ZigBee Lighting Reference Design
7.4 Building the Firmware Application
The instructions below describe how to build the bulb firmware.
1. Install Ember ZNetPRO 5.7.4 or later.
Note: You must have installed Simplicity Studio version 3 or later for this stack release to work.
2. Point app builder to your 5.7.4 release
a. Simplicity Studio → preferences → Simplicity Studio → SDKs
b. Click on the "add" button to add the 5.7.4 software stack
3. Create a project with either the HA Dimmable, Ha Color Temperature, or HA Color Control light bulb.
a. File → new → Silicon Labs AppBuilder project
b. Select ZCL Application Framework V2 and click Next.
c. Select the option with "SOC" and click Next.
d. Uncheck "start with a blank application" and scroll down to select one of the lighting reference designs: HaColorControlLight,
HaColorTempLight, or HaDimmableLight.
e. Select a project name and click Next.
f. Select the part.
Note: These reference applications are designed for the EFR32 or the EM3585. Selecting a different part will require some
additional configuration not discussed in this document.
g. Click Finish to create the project.
4. Click the Generate button to create the IAR project.
Note: You can reconfigure the .isc file to suit your project's needs, but you must click the Generate button after any configuration.
5. Compile the project in Simplicity Studio.
At this point you can load the image into the lighting reference design.
Note: Because the reference designs support OTA firmware upgrade, you must load the correct bootloader for your chip.
7.5 Lighting Reference Design Cluster Documentation
Several plugins were developed or altered as part of the lighting reference design work. This section documents these new clusters.
Here are some highlights of the new functionality:
• Ability to configure radio transmit power and specific bulb-related attributes (such as PWM frequency) using OTA commands
• Ability to execute RF test commands using a radio command
• Ability to directly configure the PWM pulse width for individual PWMs using a CLI command
• An example on setting up and using an LED calibration table in the chip's memory
7.5.1 Bulb-UI
The purpose of this plugin is to drive the user interface for the bulb. The user interface is primarily concerned with deciding when to join
or leave a network. It does this by counting the number of rapid power cycles. By default, power cycling the bulb 10 times in quick
succession (< 8 seconds of on time) will cause a joined bulb to leave the network and begin to search for a new network.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 20
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Firmware Details for the ZigBee Lighting Reference Design
7.5.1.1 Theory of Operation
The primary task of the bulb-ui plugin is to manage the network connectivity state. When the bulb is not on the network, it will kick off
the joining procedure. It begins by scanning on the HA preferred channels. If it does not find a joinable network, it will continue on to
scanning on all legal 802.15.4 channels. It proceeds to scan for up to 20 times or until it finds a joinable network, at which point it will
stop scanning. If the bulb-ui plugin has not found a network, it will assume there are no legal networks at this time, operate as a normal
non-connected LED bulb, and kick off a new join procedure after a power cycle.
Once on the network, the bulb-ui plugin will proceed to user interface mode. A user can input commands to the bulb by means of a
series of rapid on/off power cycles. The bulb will count these power cycles and take actions as indicated by the number of power cy-
cles. If the bulb is power cycled 4 times, it will enter identify mode. The bulb will begin to blink at the identify rate of 0.5 Hz (as defined
by the bulb project’s callbacks.c file) for 3 minutes, as specified by the EZ Mode commissioning behavior in the ZigBee Home Automa-
tion profile.
Power cycling the bulb between 5 and 9 times will initiate rejoin behavior. The bulb is designed to be a non-sleepy end device. As such,
it relies on a connection through a parent device for network connectivity. If this connection becomes unstable, the user can initiate the
rejoin behavior to coerce the bulb into finding a new, perhaps better parent through which to communicate with the network.
Power cycling the bulb for 10 or more times will force the bulb to leave the network and attempt to find a new network. A side effect of
this behavior is that all of the bulb parameters (on/off, level, color control if available) will be reset to the factory defaults.
Lastly, to facilitate manufacturing tests, the lighting reference designs include our manufacturing library CLI plugin for driving the radio
in test modes so that technicians may make various RF parameter measurements. This can be tricky because the manufacturing library
cannot be called if the bulb is in the middle of scanning for a network. To facilitate this behavior, the manufacturing library CLI plugin
has a command to enable the manufacturing library token. If this token has been enabled, the bulb ui will pause 10 seconds before
kicking off the network scan in order to allow the test equipment time to invoke the manufacturing library behavior. There are more
details on this behavior in the manufacturing library CLI plugin section.
7.5.1.2 Configurable Parameters
The bulb user interface has no parameters that are configurable through application builder. It does, however, have some parameters
that are configurable through the configuration cluster server. These are the minimum and maximum on time for counting power up
pulses, as well as the default bulb power up behavior.
The minimum on time parameter is used to tell the bulb-ui to ignore really short pulses. By default, the plugin will ignore pulses that are
shorter than 100 mS. However, setting this parameter, the user can configure the bulb to ignore longer on time pulses so they will not
be counted as part of the bulb user interface.
The maximum on time parameter is the amount of time that the bulb will wait before it declares a final value for the number of pulses.
This is 2 seconds by default.
Finally, the user can configure the default power up behavior for the bulb. There are three options: turn the bulb on to full brightness on
power up, turn the bulb off on power up, and return the bulb to the previous state on power up. By default, the bulb will return to the last
known state on power up.
7.5.1.3 CLI Commands
The bulb-ui plugin has no CLI commands.
7.5.1.4 Mfg-lib-cli
To assist with the manufacturing process, the lighting reference designs include the manufacturing library as well as the manufacturing
library CLI commands. On the factory floor, a lighting module that has been programmed with these images may be used to also make
radio measurements.
7.5.1.5 Theory of Operation
The purpose of the manufacturing library CLI plugin (or mfg-lib CLI plugin for short) is to allow access to commands that will put the
radio into test mode so that the radio modules can be tested at manufacturing time with the final bulb firmware images.
7.5.1.6 Configurable Parameters
There are no configurable parameters for the manufacturing library CLI plugin.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 21
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Firmware Details for the ZigBee Lighting Reference Design
7.5.1.7 CLI Commands
Table 7.1. Commands for the Manufacturing Library Command Line Interface (CLI)
CLI Command
Notes
plugin mfglib mfgenable <0|1>
Set the token to pause bulb-ui plugin from scanning for channels
to allow for starting the manufacturing library before the stack op-
eration begins. 0 clears the token, 1 sets the token.
plugin mfglib start <0|1>
Starts the manufacturing library, which will prevent network activi-
ty as well as enable the rest of the manufacturing library com-
mands. The argument dictates whether or not to track incoming
messages and provide receiver statistics on the incoming pack-
ets.
plugin mfglib stop
Stops the manufacturing library.
plugin mfglib set-channel <channel>
Set the radio to the specified channel. Note: channel must be be-
teween 11 and 26 inclusive.
plugin mfglib set-power <power> <mode>
Sets the radio power to be used for manufacturing library transmit
commands. The mode, enables or disables boost mode for the
EM35x series of chips.
plugin mfglib stream <start|stop>
plugin mfglib tone <start|stop>
Note: There are additional CLI commands for use with the manufacturing library plugin. They can be explored by typing the command
"plugin mfglib <enter>" and seeing a list of valid commands. Above we are detailing the commands that are most commonly useful to a
lighting reference design during the manufacturing process.
Here is the procedure for starting the manufacturing library:
1. Connect to the lighting reference design and issue the mfgenable command: “plugin mfglib mfgenable 1”
2. Power cycle the reference design.
3. Within 10 seconds of power cycle, issue the start command “plugin mfglib start 0”
At this point, any of the manufacturing library commands can be safely executed without interference from the networking stack.
For example to take measurements on a modulated tone on channel 15 at a power of 20, issue the following commands:
1. plugin mfglib set-channel 15
2. plugin mfglib set-power 20 0
3. plugin mfglib stream start
4. At this time, take your measurements.
5. plugin mfglib stream stop
Note: Transmit power of 20 is only valid for certain flavors of the EFR32 radio chip at this time.
When the manufacturing tests are completed, it is important that you disable the manufacturing library delay at bootup with the following
command:
1. plugin mfglib mfgenable 0
It is not necessary to issue the manufacturing library stop command unless you wish to initiate normal networking activity without a
power cycle as the manufacturing library operation will be reset at the next power cycle.
7.5.2 Configuration Cluster Server
The configuration cluster server plugin allows a user to change certain parameters of the light bulb at the time of manufacture. This
prevents the need for recompiling the images for small changes to the design. For example, different models of bulb may require that
the PWMs be driven at different frequencies or that the transmit power be adjusted to meet FCC requirements. The configuration clus-
ter server allows manufacture time configuration of these parameters so that the same binary image may be used across multiple mod-
el numbers.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 22
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Firmware Details for the ZigBee Lighting Reference Design
7.5.2.1 Theory of Operation
This feature uses a Silicon Labs custom cluster to define special ZigBee cluster library commands that contain configuration information
for pre-selected parameters of the lighting reference designs. Any ZigBee coordinator (including the Ha Gateway Reference Design)
that is set up with the Silicon Labs custom clusters for OTA configuration can send these commands to the lighting reference design to
configure these parameters. It is important to note that these parameters are stored in non-volatile memory and will be a new, perma-
nent configuration for the device after it has been configured. Also, one of the parameters is a lock down feature that prevents further
configuration of these parameters once the device has been shipped into the field.
The first step in the process is to connect the lighting device to a gateway that has this cluster enabled. Once the lighting design joins
the network, the gateway can send it a command to configure any of the configurable parameters. Upon receiving the configuration
message from the gateway, the lighting reference design will update its non-volatile memory storage of the configuration parameters. It
is important to note that configuration parameters are utilized at bootup, and the changes do not take effect until the next power cycle.
7.5.2.2 Configurable Parameters
Table 7.2. Configurable Parameters
Name
Creator
Description
OTA_CONFIG_LOCK
0x7000
Token to prevent OTA configuration and
OTA RF test commands from working
TX_POWER
0x7001
0x7002
0x7003
0x7004
Sets the TX power for channels 11-24
Sets the TX power for channel 25
Sets the TX power for channel 26
TX_POWER25
TX_POWER26
MODEL_NAME
Configures the model identifier attribute in
the basic cluster
MANUFACTURER_NAME
HW_VERSION
0x7005
0x7006
Configures the manufacturer name attrib-
ute in the basic cluster
Configures the hardware version attribute
in the basic cluster
BULB_PWM_FREQUENCY_HZ
BULB_PWM_MIN_ON_US
0x7007
0x7008
Sets the frequency of the PWM signals
When the bulb is on and the level is set to
1, this is the amount of time per cycle that
the PWM will be in the active state
BULB_PWM_MAX_ON_US
0x7009
When the bulb is on and the level is set to
the maximum, this is the amount of time
per cycle that the PWM will be in the active
state
BULB_UI_MIN_ON_TIME
BULB_UI_TIMEOUT
0x700A
0x700B
When power cycling the bulb, this sets the
minimum time the bulb must be on to regis-
ter as a single power cycle event
When power cycling the bulb, this sets the
amount of time the bulb must be on to reset
the boot counter and take the appropriate
action (if any)
BULB_UI_POWER_UP_BEHAVIOR
0x700C
This sets the on/off state of the bulb after a
power cycle. It can either be always on (0),
always off (1) or last known state (2)
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 23
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Firmware Details for the ZigBee Lighting Reference Design
7.5.2.3 CLI Commands—Device
The parameters may be configured at manufacture time through direction connection to the lighting design by means of the standard
command line interface. Here are a list of these commands:
Table 7.3. Commands for the Configuration Cluster Server Plugin
CLI Command
Notes
plugin configuration-server lock <true|false
Will enable/disable the custom OTA commands from the server.
Note: It is important that the bulb firmware be locked before final
shipment to end customers.
plugin configuration-server set <creator> {<data>}
plugin configuration-server read
Sets the configuration token specified by the creator to the value
in data. Note: the data is little endian (i.e. least significant byte
first) in the format of {XX XX … }, where XX is 2 hexadecimal dig-
its specifying a single byte of data.
Print out the complete list of the configuration tokens as well as
their current values.
For example, to configure the device for a PWM frequency of 700 Hz (which is 0x02BC), issue the following command:
• plugin configuration-server set 0x7007 {BC 02}
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 24
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Firmware Details for the ZigBee Lighting Reference Design
7.5.2.4 CLI Commands—Gateway
The parameters may be configured at manufacture time using over the air commands from a gateway that supports the ota configura-
tion client cluster. This is particularly convenient if the lighting module resides inside a finished light bulb product, and provides flexibility
for the user to set up the manufacturing flow.
Table 7.4. Commands for the Configuration Cluster Client (Gateway) Device
CLI Command
Notes
zcl mfg-code 0x1002
Sets the manufacturing code to 0x1002, which is the Silicon Labs
code used for these custom clusters.
Note: The manufacturing code will remain set until it is explicitly
unset, and normal CL commands will not work when in this mode.
zcl mfg-code 0
Unsets the manufacturing code.
zcl ota-config lock
Explicit command to lock the OTA configuration functionality of
the reference designs
zcl ota-config read <creator>
Command to read the data from the token specified by the creator
value
zcl ota-config setToken <creator> {<data>}
Sets the configuration token specified by the creator to the value
in data. Note: the data is little endian (i.e. least significant byte
first) in the format of {XX XX … }, where XX is 2 hexadecimal dig-
its specifying a single byte of data.
zcl ota-config unlock {<unlock key>}
custom send <device entry>
Unlocks the OTA configuration functionality of the reference de-
sign. See an FAE for support.
Send the command to the reference design from the HA Gateway
Reference Design.
Here is an example of the commands used to set the PWM frequency of a light bulb that exists at location 0 in the device table to 700
Hz.
Note: It is assumed the gateway already created a network and that the lighting reference design has joined this network:
1. zcl mfg-code 0x1002
2. zcl ota-config setToken 0x7007 {BC 02}
3. custom send 0
4. zcl mfg-code 0
Note: If you are setting multiple configuration parameters using OTA commands, the final "zcl mfg-code 0" is only required after the
final message has been sent to the device being configured.
7.5.3 Manufacturing Library OTA
This plugin implements the manufacturing library custom cluster from Silicon Labs. It provides a means, through radio messages, to put
the device into RF testing mode. In the past, enabling such features on a device required the user to physically alter the device (by
cutting the case, adding a connector, and connecting to a ribbon cable). For some tests, this is practically impossible. For others, it will
alter the results of the test (such as for FCC tests). To overcome these issues, Silicon Labs developed a way to invoke the manufactur-
ing library commands using radio commands.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 25
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Firmware Details for the ZigBee Lighting Reference Design
7.5.3.1 Theory of Operation
Silicon Laboratories has created a custom ZigBee cluster that details RF commands for the purpose of putting the device receiving the
commands into manufacturing test mode. Specifically, it can force the device to transmit an unmodulated tone, transmit a modulated
tone, or receive packets for a short time to check the RX path of the device in the field.
First, the user must obtain a gateway that supports this functionality. Our HaGatewayReference application supports the MFGLIB Clus-
ter, although it is possible to use our development environment to create such a gateway.
After the gateway creates the network and the lighting reference design joins the network, the gateway can send commands to the
lighting reference design to tell it which RF test to perform and which parameters to use, such as channel and TX power. Each of the
RF commands also includes a timeout parameter, which sets the amount of time (in milliseconds) to enable the command. Using a
timeout parameter of 0 means that the device will remain in the specified RF test until the next device power cycle.
7.5.3.2 Configurable Parameters
There are no configurable parameters for these plugins.
7.5.3.3 CLI Commands—Device
There are no device side CLI commands for this plugin.
7.5.3.4 CLI Commands—Gateway
The following table details the commands for sending the manufacturing test commands over the air from a gateway that supports this
functionality.
Table 7.5. Commands for the Configuration Cluster Client (Gateway) Device
CLI Command
Notes
zcl mfg-code 0x1002
Sets the manufacturing code to 0x1002, which is the Silicon Labs
code used for these custom clusters.
Note: The manufacturing code will remain set until it is explicitly
unset, and normal CL commands will not work when in this mode.
zcl mfg-code 0
Unsets the manufacturing code.
zcl mfglib rx-mode <channel> <power> <time>
Put the device into RX mode. Note: when in RX mode, the device
under test will keep track of the number of packets received, the
RSSI and the LQI of the first packet received. It is recommended
to use a non-zero timeout as these parameters are stored in vola-
tile memory and will be reset at power cycle.
zcl mfglib stream <channel> <power> <time>
zcl mfglib tone <channel> <power> <time>
Set the radio to transmit a modulated carrier. Note: the carrier will
be modulated with a random stream of characters.
Set the radio to transmit a modulated carrier.
Note: The carrier will be modulated with a random stream of char-
acters.
custom send <device entry>
Send the command to the reference design from the HA Gateway
Reference Design.
Here is an example of the commands used to command the lighting design to transmit a modulated carrier at channel 15 with a power
of 20 dBm until the next device power cycle.
Note: It is assumed the gateway already created a network and that the lighting reference design has joined this network:
1. zcl mfg-code 0x1002
2. zcl mfglib-stream 15 20 0
3. custom send 0
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 26
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Firmware Details for the ZigBee Lighting Reference Design
7.5.4 LED-RGB-pwm
This plugin takes commands from the on/off, level control, and color control plugins. It will then compute the correct PWM drive values
to implement the current color mode output based on the on/off and level parameters for three separate strings of red, green, and blue
LEDs.
7.5.5 LED-Temp-PWM
This plugin takes commands from the on/off, level control, and color temperature server plugins. It then computes the correct PWM
drive values to implement the current temperature and level. It assumes that it is driving two independent strings of LEDs, where one
LED string is a warm LED string and one LED string is a cool LED string.
Note: The RD-0085 hardware has color temperature LEDs at 2200LK and at 5000K. The PWM signals are used to blend these two
colors to create intermediate color temperatures. The RD-0035 hardware does not have color temperature LEDs and cannot demon-
strate this feature.
7.5.6 LED-Dim-PWM
This plugin takes commands from the on/off cluster and the level control cluster and translates them into the PWM drive values for a
single PWM. It is intended for use by the dimmable LED light bulb reference design. Because it controls a single LED string, it does not
support any of the color modes.
7.5.7 Diagnostic Server
This plugin has been extended to record the RSSI, LQI, and number of retransmissions per APS packet sent. The plugin will populate
the appropriate attributes of the diagnostic server so that they may be read by other devices or reported by the bulb.
7.5.8 Bulb-pwm-cli
The lighting reference designs include pwm drivers designed to drive most standard LED bulb architectures. The bulb pwm CLI plugin
facilitates the testing of this hardware. It includes commands for setting the PWMs to different output values. Note: these values are
hardware specific, so this plugin will require knowledge of your specific device’s chip architecture and output frequency.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 27
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Firmware Details for the ZigBee Lighting Reference Design
7.5.8.1 Theory of Operation
The purpose of this plugin is to allow the user, through the CLI, to dial in specific pulse widths in the PWM hardware. This is done by
means of a direct serial connection either through the WSTK or over the serial lines in the 10-pin connector.
You can look to the hal bulb pwm driver section below for more details on the PWM operation, but here are a few details you need to
know to use this CLI.
By default, the PWMs are set to operate at 1 kHz. The EM35x series of chips will drive the peripheral clock at 6 MHz, which means that
it will take 6,000 ticks for the PWM to count through an entire cycle. This means that setting a PWM value of 0 will drive the signal to
low the entire time, and setting the PWM value of 6000 will drive it to full high through the entire PWM cycle.
For the EFR32 series of chips, the peripheral clock is running much faster. It will take 38,400 ticks for the PWM to count through an
entire cycle at 1 kHz. Therefore, you need to set the PWM to 38,400 to drive the PWM to full on.
Finally, the PWM drive has the concept of a channel handler, or channel for short. Because the lighting design uses multiple PWM
channels across multiple PWM peripherals, it was convenient to have a single, monotonic number set for all of the channels. Here is a
table for the EFR:
Table 7.6. Default PWM Channel Configurations—EFR32
Channel
Function
White
GPIO Port
VPIO Pin
Timer
Timer Channel
1
2
3
4
5
6
B
B
B
C
D
C
15
14
11
10
15
11
Timer 0
Timer 0
Timer 0
Timer 1
Timer 1
Timer 1
0
1
2
0
1
2
Low temp White
Status LED
Red
Green
Blue
Table 7.7. Default PWM Channel Configurations—EM35x
Channel
Function
White
Red
GPIO Port
VPIO Pin
Timer
Timer Channel
1
2
3
4
B
B
B
B
1
2
3
4
Timer 2
Timer 2
Timer 2
Timer 2
1
2
3
4
Green
Blue
7.5.8.2 Configurable Parameters
There are no configurable parameters for this plugin.
7.5.8.3 CLI Commands
Table 7.8. CLI Commands for Driving the PWM Outputs
Notes
CLI Command
plugin bulb-pwm set <channel> <value>
This will set the PWM of the specified channel to the specified val-
ue.
Using these CLIs is pretty straightforward. If you wish to set the blue PWM to maximum value for the EFR32, use the following com-
mand:
• plugin bulb-pwm set 6 38400
And if you wish to set the blue PWM to maximum value for the EM35x, use the following command:
• plugin bulb-pwm set 4 6000
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 28
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Firmware Details for the ZigBee Lighting Reference Design
7.5.9 Hal-Bulb-PWM-Driver
The hal bulb PWM driver configures the PWM hardware to drive external LEDs. These PWM signals can be connected directly to bulb
power supplies to drive the LED strings to the levels required by the ZigBee communication.
7.5.9.1 Theory of Operation
The pinouts and hardware is specified by a board header file. After creating a new lighting reference design project in Simplicity Studio,
there will be a file of the form <project>_board.h, also known as the board header file. It will contain a section in which you may recon-
figure the PWM definitions depending on your final hardware. Please do not change these unless you know what you are doing. The
default settings are designed to work with the lighting reference design hardware, and any changes will make this project incompatible
with the lighting reference design.
Upon boot up, the hal bulb PWM driver will use the settings in the board header file and use those settings to set up the hardware:
which GPIO drives which PWM channel, and how are these tied to the functionality required of the lighting reference design (such as
the white LED).
Also as part of the startup configuration, the hal bulb PWM driver will make calls into the protocol to obtain the PWM drive frequency,
which for the lighting reference designs is one of the configurable parameters.
Finally, the hal bulb PWM driver implements a generic blinking function. It provides the ability to turn the LEDs on for a fixed amount of
time, turn the LEDs off for a fixed amount of time, blink at a specific rate for a specific number of times, and finally to blink a generic
pattern for a specific number of times. Note that at the end of these blinking patterns, the hal bulb PMW driver will make a call into the
protocol stack to indicate the blinking finished, and will expect calls from the protocol stack to set the new, non-blinking PWM values
appropriate for the on/off, level, and color parameters.
7.5.9.2 Configurable Parameters
There is one configurable parameter for this plugin. The blink pattern is stored in a statically allocated array. The size of this array is
configurable through the plugin UI in Simplicity Studio.
7.5.9.3 CLI Commands
See the above plugin for instructions on driving this plugin through CLI ineraction.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 29
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Ecosystem Considerations
8. Ecosystem Considerations
The lighting reference design firmware examples have been made to be HA certifiable. As such, they should work with any of the Zig-
Bee certified Home Automation gateways in the market. However, each gateway may have some individual requirements beyond the
ZigBee Home Automation requirements. It is therefore recommended that you contact the individual gateway manufacturers for support
in getting your device onto their gateway. Several gateway manufacturers have developer websites for such tasks.
In our testing, we have discovered that virtually all gateway manufacturers require a device to support two optional attributes in the
Basic cluster: manufacturer name and model identifier. While our reference designs have values for these attributes that are reflective
of the Silicon Laboratories reference design work, it is expected that each individual customer would customize these attributes for their
own product.
In our testing, we have also discovered that a few of the gateway manufacturers use the manufacturer name and model identifier
(among other things) to implement a white list. A white list is a list of approved devices that the gateway will allow onto its network. If
your device is not on the white list, it will not be allowed to join the network. For these gateways, you will need to contact the gateway
manufacturer directly to add your manufacturer name and model identifier to their gateway's white list.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 30
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Engineering Tests
9. Engineering Tests
This reference design has undergone the following product testing for pre-certification purposes:
• ZigBee Home Automation (HA) v1.2
• FCC Emissions
• Antenna Radiation Patterns
9.1 Zigbee Home Automation (HA) v1.2
All modules have gone through a preliminary HA 1.2 testing to verify their compliance with the ZigBee standard.
9.2 FCC Emissions Testing
All modules have gone through a preliminary FCC pre-scan testing to verify their compliance with FCC Part 15 restrictions. Such testing
is done to ensure that customers are given a design that can pass FCC, but it does not transfer FCC compliance to modules built ac-
cording to this reference design, even if the design is copied exactly.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 31
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Manufacturing Tests for RD-0085
10. Manufacturing Tests for RD-0085
This section describes how a user can develop a low cost manufacturing test methodology in order to test products that utilize this ref-
erence design. It will outline recommended test equipment and test procedure.
10.1 Test Coverage
By following these guidelines, the following items will be tested and verified for functionality.
• RF TX/RX Performance
• Current consumption
• PWM functionality
• Common ZigBee operations
• Crystal frequency offset measurement
10.2 Test Equipment List
The test system is composed of the following components:
• Desktop PC
• RF Shielded Box
• Power Supply (Agilent E3646A)
• 2x WSTK programming/packet trace adapters (Silicon Labs)
• Golden Node to act as a ZigBee coordinator
• Frequency counter accurate to 1 ppm
• Device under test (DUT)
10.3 Test System Diagram
LEDs
Frequency
Counter
Power Supply
Golden
Node
WSTK
DUT
PC
WSTK
10.4 Test System Connection Procedure
Wire the system as indicated above. All WSTK adapters will be connected to the PC through USB. One adapter will connect to the DUT
to both reprogram and interact with the DUT, and the second one will connect to the Golden Node for testing network functionality. The
WSTK adapters may need to be powered off during some tests. This can be done by adding a power switch to the test jig, or by using
the power selection switch already on the WSTK.
Indicators as simple as LEDs may be used to verify PWM functionality. The only thing in the shielded box should be connectors linked
to the DUT, and connectors for 50 ohm antennas.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 32
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Manufacturing Tests for RD-0085
10.5 Configuring the WSTK Adapters
For this setup, the PC will communicate to the WSTK Adapter over USB. Each adapter has a unique J-Link Serial Number that is dis-
played on the LCD screen. This number will be used to reference to the specific WSTK and communicate with it.
10.6 Communicating with Targets
Communication to the WSTK needs to be established through the Simplicity Commander tool. This includes commands to program the
DUT or shut off programming capabilities of the WSTK itself, if that is required.
Communcation to the DUT can be established through serial connection with the Virtual COM port of the WSTK. All device behavior
tests are performed by sending specific commands which the device interprets and acts upon.
10.7 Additional Details
For a more thorough checklist, please refer to Application Note AN700 or contact Silicon Labs (http://www.silabs.com) for more informa-
tion.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 33
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Manufacturing Tests for RD-0035
11. Manufacturing Tests for RD-0035
This section describes how a user can develop a low cost manufacturing test methodology in order to test products that utilize this ref-
erence design. It will outline recommended test equipment and test procedure.
11.1 Test Coverage
By following these guidelines, the following items will be tested and verified for functionality:
• RF TX/RX performance
• Current consumption
• PWM functionality
• Common ZigBee operations
• Frequency offset
11.2 Test Equipment List
The test system is composed of the following components:
• Desktop PC
• RF Shielded Box
• Power Supply (Agilent E3646A)
• PoE Hub (Netgear Prosafe 108P)
• 2 x ISA3 programming/packet trace adapters (Silicon Labs ISA3)
• Golden Node
• Spectrum Analyzer or frequency counter accurate to 1 ppm
• Device under test (DUT)
11.3 Test System Diagram
LEDs
Spectrum
Analyzer
Power Supply
Golden
Node
ISA3
DUT
PC
PoE HUB
ISA3
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 34
®
UG252: ZigBee Lighting Reference Design Demo Board Kit User's Guide (RD-0085-0401, RD-0035-0601)
Manufacturing Tests for RD-0035
11.4 Test System Connection Procedure
Wire the system as indicated above. Both ISA3 adapters and the PC will be connected to the PoE hub. One ISA3 adapter will connect
to the DUT to both reprogram and interact with the DUT, whereas the second ISA3 adapter will connect to the Golden Node for testing
network functionality. The ISA3 Adapters connected to the DUT should never be turned off. Instead, power for the DUT will be provided
by the Power Supply for live current measurements.
Indicators as simple as LEDs may be used to verify PWM functionality. The only thing in the shielded box should be connectors linked
to the DUT, and connectors for 50 ohm antennas.
11.5 Configuring the ISA3 Adapters
For this setup, the PC will communicate to the ISA3 Adapter with an Ethernet connection over Telnet. To do this, first the ISA3 adapters
need to be configured to use a static IP address. For instructions on how to set up static IPs, reference sections 6.3 and 6.4 in Silicon
Labs' UG110 User's Guide. Use the Admin interface over USB to set up the ISA3 adapters.
11.6 Communicating with Targets
Through the Telnet interface, both the ISA3 adapters and their respective connected targets can be communicated with simultaneously.
To communicate with the ISA3 adapters, a Telnet session should be opened to its static IP at port 4902. To communicate with a target
connected to the ISA3 adapter through virtual UART, connect to the ISA3's static IP at port 4900.
Once connected, press Enter, or send a '\r\n' sequence which will result in a prompt ending with a '>' character.
11.7 Additional Details
For a more thorough checklist, please refer to Application Note AN700 or contact Silicon Labs (http://www.silabs.com) for more informa-
tion.
silabs.com | Smart. Connected. Energy-friendly.
Rev. 0.3 | 35
Simplicity Studio
One-click access to MCU and
wireless tools, documentation,
software, source code libraries &
more. Available for Windows,
Mac and Linux!
IoT Portfolio
www.silabs.com/IoT
SW/HW
www.silabs.com/simplicity
Quality
www.silabs.com/quality
Support and Community
community.silabs.com
Disclaimer
Silicon Labs intends to provide customers with the latest, accurate, and in-depth documentation of all peripherals and modules available for system and software implementers using or
intending to use the Silicon Labs products. Characterization data, available modules and peripherals, memory sizes and memory addresses refer to each specific device, and "Typical"
parameters provided can and do vary in different applications. Application examples described herein are for illustrative purposes only. Silicon Labs reserves the right to make changes
without further notice and limitation to product information, specifications, and descriptions herein, and does not give warranties as to the accuracy or completeness of the included
information. Silicon Labs shall have no liability for the consequences of use of the information supplied herein. This document does not imply or express copyright licenses granted
hereunder to design or fabricate any integrated circuits. The products are not designed or authorized to be used within any Life Support System without the specific written consent of
Silicon Labs. A "Life Support System" is any product or system intended to support or sustain life and/or health, which, if it fails, can be reasonably expected to result in significant personal
injury or death. Silicon Labs products are not designed or authorized for military applications. Silicon Labs products shall under no circumstances be used in weapons of mass
destruction including (but not limited to) nuclear, biological or chemical weapons, or missiles capable of delivering such weapons.
Trademark Information
Silicon Laboratories Inc.® , Silicon Laboratories®, Silicon Labs®, SiLabs® and the Silicon Labs logo®, Bluegiga®, Bluegiga Logo®, Clockbuilder®, CMEMS®, DSPLL®, EFM®, EFM32®,
EFR, Ember®, Energy Micro, Energy Micro logo and combinations thereof, "the world’s most energy friendly microcontrollers", Ember®, EZLink®, EZRadio®, EZRadioPRO®,
Gecko®, ISOmodem®, Precision32®, ProSLIC®, Simplicity Studio®, SiPHY®, Telegesis, the Telegesis Logo®, USBXpress® and others are trademarks or registered trademarks of Silicon
Labs. ARM, CORTEX, Cortex-M3 and THUMB are trademarks or registered trademarks of ARM Holdings. Keil is a registered trademark of ARM Limited. All other products or brand
names mentioned herein are trademarks of their respective holders.
Silicon Laboratories Inc.
400 West Cesar Chavez
Austin, TX 78701
USA
http://www.silabs.com
相关型号:
©2020 ICPDF网 联系我们和版权申明