SI2110-X-FMR [SILICON]
Telecom Circuit, 1-Func, CMOS, ROHS COMPLIANT, QFN-44;型号: | SI2110-X-FMR |
厂家: | SILICON |
描述: | Telecom Circuit, 1-Func, CMOS, ROHS COMPLIANT, QFN-44 |
文件: | 总94页 (文件大小:1241K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Si2107/08/09/10
SATELLITE RECEIVER FOR DVB-S/DSS WITH
QUICKLOCK AND QUICKSCAN
Features
ꢀ Single-chip tuner, demodulator, ꢀ Automatic acquisition and fade
and LNB controller
recovery
ꢀ DVB-S- and DSS-compliant ꢀ Automatic gain control
ꢀ QPSK/BPSK demodulation
ꢀ Integrated step-up dc-dc
ꢀ On-chip blind scan accelerator
with QuickScan (Si2109/10 only)
converter for LNB power supply ꢀ DiSEqC™ 2.2 support
(Si2108/10 only)
ꢀ Power, C/N, and BER estimators
Pin Assignments
ꢀ Input signal level:
2
ꢀ I C bus interface
–82 to –10 dBm
Si2107/08/09/10
ꢀ 3.3/1.8 V supply, 3.3 V I/O
ꢀ Symbol rate range:
ꢀ Pb-free/RoHS-compliant
1 to 45 MBaud
package
44 43 42 41 40 39 38 37 36
1
VDD_LNA
REXT
35 XTAL1
Applications
2
3
4
5
6
7
8
9
GND
34 XTAL2
ADDR
33 VDD_XTAL
32 XTOUT
VDD_MIX
VDD_BB
VDD_ADC
VSEN/TDET
LNB1/TGEN
ISEN
ꢀ
ꢀ
ꢀ
Set-top boxes
Digital video recorders
Digital televisions
ꢀ
ꢀ
Satellite PC-TV
SMATV trans-modulators
(Satellite Master Antenna TV)
31 VDD_PLL33
30 INT/RLK/GPO
29 TS_ERR
Top
View
28
TS_VAL
27 TS_SYNC
26 SDA
LNB2/DRC 10
RESET 11
PWM/DCS 12
VDD_DIG18 13
25 SCL
Description
24 TS_DATA[7]
GND
TS_DATA[6]
23
The Si2107/08/09/10 are a family of pin-compatible, complete front-end solutions
for DSS and DVB-S digital satellite reception. The IC family incorporates a tuner,
demodulator, and LNB controller into a single device resulting in significantly
reduced board space and external component count. The device supports symbol
rates of 1 to 45 MBaud over a 950 to 2150 MHz range. A full suite of features
including automatic acquisition, fade recovery, blind scanning, performance
monitoring, and DiSEqC Level 2.2 compliant signaling are supported. The Si2108/
10 further add short circuit protection, overcurrent protection, and a step-up dc-dc
controller to implement a low-cost LNB supply solution. Si2109/10 versions
include a hardware channel scan accelerator for fast “blindscan”. The Si2107/08/
09/10 family features new channel detection and acquisition technology:
QuickLock for Si2107/08/09/10 and QuickScan for Si2109/10. QuickLock
achieves fast channel acquisition and QuickScan, fast channel detection. An I2C
bus interface is used to configure and monitor all internal parameters.
14 15 16 17 18 19 20 21 22
Functional Block Diagram
Acquisition Control
AGC
TS_CLK
TS_DATA[7:0]
TS_VAL
RS
Decoder
Viterbi
Decoder
Tuner
Demodulator
RFIP
TS_SYNC
TS_ERR
VSEN/TDET
LNB2/DRC
ISEN/NC
LNB1/TGEN
PWM/DCS
LNB Control
I2C Interface
SCL SDA
RF Sythesizer
INT/RLK/GPO
XOUT
Preliminary Rev. 0.81 6/06
Copyright © 2006 by Silicon Laboratories
Si2107/08/09/10
This information applies to a product under development. Its characteristics and specifications are subject to change without notice.
Si2107/08/09/10
2
Preliminary Rev. 0.81
Si2107/08/09/10
TABLE OF CONTENTS
Section
Page
1. Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2. Typical Application Schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
3. Bill of Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
4. Part Versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
5. Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
5.1. Tuner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
5.2. Demodulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
5.3. DVB-S/DSS Channel Decoder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
5.4. On-Chip Blindscan Controller: QuickScan (Si2109/10 Only) . . . . . . . . . . . . . . . . . .21
5.5. LNB Signaling Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
5.6. On-Chip LNB DC-DC Step-Up Controller (Si2108/10 Only) . . . . . . . . . . . . . . . . . . .21
5.7. Crystal Oscillator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
6. Operational Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
6.1. System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
6.2. Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
6.3. Receiver Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
6.4. Tuning Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
6.5. Channel Decoder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
6.6. Automatic Gain Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
6.7. LNB Signaling Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
6.8. On-Chip LNB DC-DC Step-Up Controller (Si2108/10 Only) . . . . . . . . . . . . . . . . . . .32
6.9. On-Chip Blindscan Controller: QuickScan (Si2109/10 Only) . . . . . . . . . . . . . . . . . .32
2
7. I C Control Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
8. Control Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
9. Pin Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .87
10. Ordering Guide1,2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89
11. Package Outline: 44-pin QFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
12. PCB Land Pattern . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91
Document Change List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93
Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94
Preliminary Rev. 0.81
3
Si2107/08/09/10
1. Electrical Specifications
Table 1. Recommended Operating Conditions
Parameter
Ambient temperature
Symbol
Min
0
Typ
—
Max
70
Unit
°C
V
T
A
DC supply voltage, 3.3 V
DC supply voltage, 1.8 V
V
V
3.0
1.71
3.3
1.8
3.6
3.3
1.8
1.89
V
Note: All minimum and maximum specifications are guaranteed and apply across the recommended operating conditions.
Table 2. Absolute Maximum Ratings1, 2
Parameter
Symbol
Min
–0.3
–0.3
–0.3
–10
–10
–55
—
Max
3.9
Unit
V
DC supply voltage, 3.3 V
DC supply voltage, 1.8 V
Input voltage (pins 2, 3, 7, 9, 11_
Input current (pins 2, 3, 7, 9, 11)
Operating ambient temperature
Storage temperature
RF input level
V
V
3.3
1.8
2.19
V
V
V
+ 0.3
3.3
V
IN
IN
I
+10
+70
150
10
mA
°C
°C
dBm
kV
T
OP
T
STG
ESD protection (pins 1–44)
Notes:
—
2
1. Permanent damage may occur if the absolute maximum ratings are exceeded. Functional operation should be
restricted to the conditions as specified in the operations sections of this data sheet. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
2. The Si2107/08/09/10 is a high-performance RF integrated circuit. Handling and assembly of these devices should
only be done at ESD-protected workstations.
4
Preliminary Rev. 0.81
Si2107/08/09/10
Table 3. DC Characteristics
(V3.3 = 3.3 V ±10%, V1.8 = 1.8 V ±10%, TA = 0–70 ºC)
Parameter
Symbol
Test Condition
45 Mbaud, CR 7/8
20 Mbaud, CR 2/3
45 Mbaud, CR 7/8
20 Mbaud, CR 2/3
Min
—
—
—
—
2.3
0
Typ
313
298
292
217
—
Max
—
Unit
mA
mA
mA
mA
V
1
1
1
1
Supply Current, 3.3 V
I
3.3
—
Supply Current, 1.8 V
I
—
1.8
—
Input high voltage
Input low voltage
V
SCL(25), SDA(26)
SCL(25), SDA(26)
5.5
0.8
±10
IH
V
I
—
V
IL
2
Input leakage
SCL(25), SDA(26),
RESET(11),
—
—
µA
I
XTAL1(35), VSEN/
TDET(7)
Output high voltage
Output low voltage
Output leakage
Notes:
V
2.4
—
—
—
—
—
V
V
OH
V
I
0.4
±10
OL
—
µA
OL
1. LNB dc-dc converter disabled; LNB_EN (CEh[2]) = 0.
2. ISEN(9) is not tested for leakage current.
Table 4. RF Electrical Characteristics
Parameter
Input power, single channel
Aggregate input power
Input impedance, balanced
Return Loss
Symbol
Test Condition
Min
—
—
—
—
—
—
—
+5
—
—
—
—
Typ
Max
–10
–7
Unit
dBm
dBm
Ω
1
P
–82
—
i,ch
P
i,agg
Z
Z
= 75 Ω
75
—
in
SOURCE
–10
75
—
dB
Dynamic voltage gain range
Maximum voltage gain
Noise figure
∆
—
dB
GV
G
55
—
dB
V(max)
2
NF
Max gain
+9.5
+15
—
+12.5
—
dB
3
2
IP3
IP3
Min gain
dBm
dBm
dBc/Hz
dBc/Hz
°rms
LO leakage
L
950 to 2150 MHz
100 kHz offset
1 MHz offset
–70
–94
–94
2.8
LO
–97
–97
2.1
LO SSB phase noise
N
N
LO
LO
LO DSB phase noise (integrated)
10 kHz to 1/2 Baud
Rate
RF synthesizer spurious
LO oscillator settling time
Notes:
At 20 MHz offset
—
—
–40
100
—
—
dBc/Hz
µs
t
s,LO
1. For a single channel with SR = 27.5 Mbaud, CR = 7/8, and no added noise. Input power range over which bit error rate
is less than 2e-4 after Viterbi decoder.
2. Max gain = 0hFFFF in AGC settings registers (25h–26h).
Min gain = 0h0000 in AGC settings registers (25h–26h).
3. IM3 can be calculated as follows: IM3 = 2 x (IP3 – Pin).
Preliminary Rev. 0.81
5
Si2107/08/09/10
Table 5. Receiver Characteristics
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
Rf Input Frequency Range
f
950
—
2150
MHz
in
Fine Tune Step Size
f
—
1
12.2
—
—
45
—
—
kHz
MBaud
MHz
step
Symbol Rate Range
R
S
Carrier Offset Correction Range
f
—
—
±6
car_off
TQL
Carrier Lock/Acquisition Times
with QuickLock
45 MBaud, CR = 7/8 Channel
Offset = ±5 MHz*
0.02
Sec
27.5 MBaud, CR = 7/8, Channel
Offset = ±10 MHz*
—
—
—
—
—
—
0.03
0.04
0.05
0.08
0.14
0.25
—
—
—
—
—
—
Sec
Sec
Sec
Sec
Sec
Sec
20 MBaud, CR = 7/8, Channel
Offset = ±10 MHz*
10 MBaud, CR = 7/8, Channel
Offset = ±10 MHz*
5 MBaud, CR = 7/8, Channel
Offset = ±10 MHz*
2 MBaud, CR = 7/8, Channel
Offset = ±10 MHz*
1 MBaud, CR = 7/8, Channel
Offset = ±10 MHz*
*Note: For signal with C/N = 8.5 dB Pin = –40 dBm, Channel frequency = 1560 MHz.
6
Preliminary Rev. 0.81
Si2107/08/09/10
Table 6. LNB Supply Characteristics (Si2108/10 Only)
Parameter
Supply Voltage
Symbol
Test Condition
Min
8
Typ
12
Max
13.2
290
19.5
19.0
14.0
14.0
1
Unit
V
V
LNB_IN
Converter Switch Frequency
237
17.75
17.0
12.75
12.5
—
264
kHz
V
VHIGH = 1101
VHIGH = 1000
VLOW = 1101
VLOW = 1100
13 to 18 V
18.625
18.0
13.375
13.25
—
Output HIGH voltage
V
V
Output LOW voltage
V
Low to High Transition Time
High to Low Transition Time
Line Regulation
ms
ms
∆mV
18 to 13 V
—
—
1
V
= 8 to
—
—
200
CC
13.2 V
I = 500 mA
o
Load Regulation
I = 50 to
—
—
200
∆mV
o
500 mA
V
= 12 V
CC
Load Capacitance Tolerance
Output current limiting
DiSEqC 1.x
DiSEqC 2.x
ILIM = 00
—
—
—
—
0.75
0.25
550
650
1.92
24
µF
µF
400
500
1.4
20
—
mA
mA
A
ILIM = 01
—
Maximum LNB Supply Current
Tone Frequency
IMAX = 01
1.6
22
650
50
6
f
kHz
mV
%
tone
Tone Amplitude
500
40
800
60
Tone Duty Cycle
Tone Rise and Fall Time
3
10
µs
Tone Detector Frequency Capture
Range
17.6
—
26.4
kHz
Tone Detector Input Amplitude
200
—
1000
mV
pp
Note: Specifications based on recommended schematics in Figure 8 and Figure 9.
Preliminary Rev. 0.81
7
Si2107/08/09/10
Table 7. I2C Bus Characteristics
Parameter
Symbol
Test Condition
Min
0
Typ
—
Max
400
—
Unit
kHz
µs
SCL Clock Frequency
f
SCL
BUF
Bus Free Time between START and
STOP Condition
t
1.3
—
Hold Time (repeated) START Condition.
(After this period, the first clock pulse is
generated.)
t
0.6
—
—
µs
HD, STA
LOW Period of SCL Clock
HIGH Period of SCL Clock
Data Setup Time
t
1.3
0.6
100
0
—
—
—
—
—
—
—
—
µs
µs
ns
µs
ns
µs
LOW
t
HIGH
t
—
SU, DAT
HD, DAT
Data Hold Time
t
0.9
300
—
SCL and SDA Rise and Fall Time
t t
—
r, f
Setup Time for a Repeated START Con-
dition
t
0.6
SU, STA
Setup Time for STOP Condition
Capacitive Load for each Bus Line
t
0.6
—
—
—
—
µs
pF
SU,STO
C
400
B
SDA
tr
tBUF
tSU;DAT
tf
tf
tLOW
tr
tHD;STA
tSP
SCL
tSU;STO
tHD;STA
tHD;DAT
tHIGH
tSU;STA
Sr
S
P
S
2
Figure 1. I C Timing Diagram
8
Preliminary Rev. 0.81
Si2107/08/09/10
Table 8. MPEG-TS Specifications (Rising Launch and Capture)
Parameter
Symbol
Test Condition
Serial mode
Min
11.3
77
Typ
—
Max
28.6
8000
6.9
Unit
ns
Clock cycle time
t
cycle
Parallel mode
—
ns
Clock low time
Clock high time
Hold time
t
Serial mode (TSSCR = 11)
Serial mode (TSSCR = 00)
Parallel mode
5.1
—
ns
clow
12.0
39
—
15.8
4000
ns
—
ns
t
Serial mode (TSSCR = 01)
Serial mode (TSSCR = 11)
Parallel mode
5.1
12.0
39
—
—
—
6.9
15.8
4000
—
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
chigh
—
t
Normal operation
0
hold
Data delayed (TSDD = 1)
Clock Delayed (TSCD = 1)
Normal operation
—
1.5
–1.5
—
—
—
Setup time
t
—
t
t
– 1.5
—
setup
cycle
cycle
Data delayed (TSDD = 1)
Clock Delayed (TSCD = 1)
—
– 3.0
—
—
t
—
cycle
Access time
t
—
1.5
—
access
tcycle
C
L
TS_CLK
TS_DATA
thold
tsetup
taccess
Figure 2. MPEG-TS (Rising Launch and Capture) Timing Diagram
Preliminary Rev. 0.81
9
Si2107/08/09/10
Table 9. MPEG-TS Specifications (Rising Launch, Falling Capture)
Parameter
Symbol
Test Condition
Serial mode
Min
11.3
77
Typ
—
Max
28.6
8000
6.9
Unit
ns
Clock cycle time
t
cycle
Parallel mode
—
ns
Clock low time
Clock high time
Hold time
t
Serial mode (TSSCR = 11)
Serial mode (TSSCR = 00)
Parallel mode
5.1
—
ns
clow
12.0
39
—
15.8
4000
ns
—
ns
t
Serial mode (TSSCR = 01)
Serial mode (TSSCR = 11)
Parallel mode
5.1
12.0
39
—
—
—
—
6.9
15.8
4000
—
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
chigh
t
Normal operation
t
/2
cycle
hold
Data delayed (TSDD = 1)
Clock Delayed (TSCD = 1)
Normal operation
—
t
t
t
/2 + 1.5
/2 – 1.5
/2 – 1.5
/2 – 3.0
—
cycle
cycle
cycle
—
—
Setup time
t
—
—
setup
Data delayed (TSDD = 1)
Clock Delayed (TSCD = 1)
—
t
—
cycle
—
t
/2
—
cycle
Access time
t
—
1.5
—
access
tcycle
C
L
L
TS_CLK
TS_DATA
thold
tsetup
taccess
Figure 3. MPEG-TS (Rising Launch, Falling Capture) Timing Diagram
10
Preliminary Rev. 0.81
Si2107/08/09/10
8.5
8
7.5
7
975MHz
1550MHz
2150MHz
1318MHz
6.5
6
5.5
5
-100
-80
-60
-40
-20
0
Input Power (dBm)
Figure 4. Eb/No (QEF Operation) vs. Input Power for Si2107/08/09/10 (Typical)
SR = 27.5 MBaud, CR = 7/8
1
0.1
0.01
27.5Mbaud 1/2
27.5Mbaud 2/3
27.5Mbaud 3/4
27.5Mbaud 5/6
27.5Mbaud 7/8
0.001
0.0001
0.00001
0.000001
0.0000001
0.00000001
2
4
6
8
10
All tests performed with 1550 MHz, –40 dBm input
Eb/No (dB)
Figure 5. BER After Viterbi vs. Eb/No for Si2107/08/09/10
Preliminary Rev. 0.81
11
Si2107/08/09/10
Figure 6. Phase Noise Performance for Si2107/08/09/10 (Typical)
0.3
0.25
0.2
1 Mbaud
2Mbaud
5Mbaud
10Mbaud
20Mbaud
35Mbaud
45Mbaud
0.15
0.1
0.05
0
Test Conditions
Pin = –40 dBm
CR = 7/8
f = 1560 MHz
-10
-5
0
5
10
Frequency Offset of Desired Channel (MHz)
Figure 7. Frequency Offset vs. Carrier Lock/Acquisition Time for Various Baudrates Using QuickLock
(Typical)
12
Preliminary Rev. 0.81
Si2107/08/09/10
2. Typical Application Schematics
2
V D D _ L N A
A L 1 X T
A L 2 X T
1
3 5
3 4
R E X T
2
A D D R
A L
V D D _ X T
3
3 3
V D D _ M I X
O U X T T
4
3 2
V D D _ P L L 3 3
3 1
/ R L K I N / G T P O
V D D _ B B
5
V D D _ A D C
6
3 0
T S _ E R R
2 9
/ V S E E T D N T
7
1
/ L N N E B T G
T S _ V A L
2 8
8
N C / I S E N
D R C / L N B 2
T S _ S Y N C
9
2 7
S D A
1 0
1 1
1 2
1 3
2 6
R E S E T
S C L
2 5
D C S / P W M
V D D _ D I G
A 7
A 6
_ D S T A T
2 4
2 3
1 8
_ D S T A T
Preliminary Rev. 0.81
13
Si2107/08/09/10
Si2110 LNB Control
14
Preliminary Rev. 0.81
Si2107/08/09/10
Si2110 LNB Control
Preliminary Rev. 0.81
15
Si2107/08/09/10
3. Bill of Materials
Table 10. Si2107/08/09/10 Bill of Materials
Component
Description
Vendor
C1,C2,C4,C6,C10,C8,C9,C13,C14,
C15,C16
0.1 µF, X7R, ±20%
C5
0.01 µF, X7R, ±20%
33 pF, 6 V, NP0, ±10%
C3,C7,C11,C12
C19,C36
D4
33 pF, 50 V, NP0, ±10%
1
Transient voltage suppressor, 20 V
Littlefuse SMCJ20CA
Anaren B0922J7575A00
Silicon Laboratories
J1
Connector, F-type, 75 Ω, 950-2150 MHz
4.53 kΩ, 62.5 mW, ±1%
Balun transformer
R2
X1
2
TC1-5
Tuning components
Y1
20 MHz, 20 pF, 50 ppm, 20 Ω ESR
Si2107/08/09/10
U1
Notes:
1. Transient voltage suppression device should be selected to match the surge requirements of the application.
2. Tuning component values depend on balun selected and layout. Please contact Silicon Laboratories for assistance
reviewing layouts and selecting matching components.
16
Preliminary Rev. 0.81
Si2107/08/09/10
Table 11. DiSEqC 1.x LNB Supply Bill of Materials (Si2108/10 Only)
Component
C30
Description
Vendor
47 µF, 25 V, Electrolytic,± 20%
0.47 µF, 25 V, X7R,± 20%
22 nF, 25 V, X7R, ± 20%
0.22 µF, 25 V, X7R, ± 20%
4.7 µF, 25 V, X7R, ± 20%
C31
C32
C33
C34
D1
CMPSH1-4, 40 V, 1 A
ZHCS750TA, 40 V, 750 mA
Central Semiconductor
Zetex
D3
L2
MMBD1705, Dual diode, 20 V, 25 mA
Fairchild
DR78098, 33 µH, 1.2 A, 20%
SD0705-330K-R-SL
Datatronic
ACT
Q1
ZXMN3B14
FDN337N
Zetex
Fairchild
Q2
Q3,Q5,Q6
Q4
FMMT618
Zetex
Infineon
Zetex
MMBT3904
FMMT718
R5
1.3 Ω, 500 mW, ±5%
33 Ω, 250 mW, ±5%
10 kΩ, 62.5 mW, ±5%
1 kΩ, 250 mW, ±5%
680 Ω, 125 mW, ±5%
0.22 Ω, 1 W, ±5%
22 kΩ, 62.5 mW, ±1%
20 kΩ, 62.5 mW, ±5%
33 Ω, 62.5 mW, ±5%
43 kΩ, 62.5 mW, ±5%
3 kΩ, 100 mW, ±5%
2 kΩ, 250 mW, ±5%
2.2 kΩ, 62.5 mW, ±1%
R6
R7
R8
R9
R10
R11
R12,R20
R13
R14
R15
R16
R17
Preliminary Rev. 0.81
17
Si2107/08/09/10
Table 12. DiSEqC 2.x LNB Supply Bill of Materials (Si2108/10 Only)
Component
C17
Description
Vendor
1200 pF, 25 V, X7R, ± 20%
47 µF, 25 V, Electrolytic, ± 20%
0.47 µF, 25 V, X7R,± 20%
22 nF, 25 V, X7R, ± 20%
0.22 µF, 25 V, X7R, ± 20%
4.7 µF, 25 V, X7R, ± 20%
C30
C31,C35
C32
C33
C34
D1
CMPSH1-4, 40 V, 1 A
ZHCS750TA, 40 V, 750 mA
Central Semiconductor
Zetex
D3
L2
MMBD1705, Dual diode, 20 V, 25 mA
Fairchild
DR78098, 33 µH, 1.2 A, 20%
SD0705-330K-R-SL
Datatronic
ACT
L3
DR78097, 100 µH, 500 mA, 20%
SD0504-101K-R-SL
Datatronic
ACT
Q1
ZXMN3B14
FDN337N
Zetex
Fairchild
Q2
Q3,Q5,Q6
Q4
FMMT618
Zetex
Fairchild
Zetex
MMBT3904
FMMT718
R5
1.3 Ω, 500 mW, ±5%
33 Ω, 250 mW, ±5%
10 kΩ, 62.5 mW, ±5%
1 kΩ, 250 mW, ±5%
680 Ω, 125 mW, ±5%
0.22 Ω, 1W, ±5%
R6
R7
R8
R9
R10
R11
22 kΩ, 62.5 mW, ±1%
20 kΩ, 62.5 mW, ±5%
33 Ω, 62.5 mW, ±5%
43 kΩ, 62.5mW, ±5%
3 kΩ, 100 mW, ±5%
2 kΩ, 250 mW, ±5%
2.2 kΩ, 62.5 mW, ±1%
16 Ω, 250 mW, ±5%
R12,R20
R13
R14
R15
R16
R17
R18
18
Preliminary Rev. 0.81
Si2107/08/09/10
4. Part Versions
There are four pin- and software-compatible versions of
this device. All versions include the L-band tuner, DVB-
S/DSS demodulator and channel decoder, and LNB
signaling controller. Furthermore, the Si2108 and
Si2110 integrate an efficient LNB supply regulator while
allowing operation with an external LNB supply
regulator circuit. The LNB supply controller utilizes a
step-up converter architecture. In case operation with
an external regulator is desired, Si2107 and Si2109 can
be used; these do not integrate the LNB step-up dc-dc
controller.
On the other hand, the Si2109 and Si2110 integrate an
on-chip “blindscan” accelerator, QuickScan, which
allows the implementation of a very fast channel scan,
an important feature for end products targeted to free-
to-air (FTA) applications in which channel locations are
unknown. Si2107 and Si2108 do not integrate this
accelerator and are a good fit when symbol rates and
frequencies of satellite channels are known, as in the
case of pay-TV receivers or for FTA receivers in which
the embedded firmware contains the channel tuning
information. Table 13 summarizes the differences
between part versions.
Table 13. Device Versions
Part
DVB-S/DSS
LNB Supply QuickScan
Number Integrated Tuner/
Demodulator with
Integrated LNB
Regulator
Messaging
Si2110
Si2109
Si2108
Si2107
Y
Y
Y
Y
Y
N
Y
N
Y
Y
N
N
Preliminary Rev. 0.81
19
Si2107/08/09/10
solution for the free-to-air (FTA) and common interface
(CI) market. Automatic acquisition and fade recovery
5. Functional Description
The Si2107/08/09/10 is a family of highly-integrated sequencers are also included to reduce the required
CMOS RF satellite receivers for DVB-S and DSS amount of software interaction and to simplify the
applications. The device is an ideal solution for satellite overall design. The output of the demodulator is
set-top boxes, digital video recorders, digital televisions, quantized into a 4-bit number by the soft-decision
and satellite PC-TV. The IC incorporates a tuner, decoder. The use of soft-decision decoding improves
demodulator, and LNB controller into a single device the error correction capabilities of the channel decoder.
resulting in a significant reduction in board space and
5.3. DVB-S/DSS Channel Decoder
external component count. The device supports symbol
rates of 1 to 45 Mbaud over a 950 to 2150 MHz range. The Si2107/08/09/10 integrates a full-channel decoder,
A full suite of features including automatic acquisition, which can be configured in either DSS or DVB-S mode
fade recovery, blind scanning, performance monitoring, and consists of a soft-decision Viterbi decoder, de-
and DiSEqC™ Level 2.2 compliant signaling are interleaver, Reed-Solomon decoder, and energy-
supported. The Si2110 and Si2108 further add short- dispersal descrambler.
circuit protection, overcurrent protection, and a step-up
5.3.1. Viterbi decoder
dc-dc controller to implement a low-cost LNB supply.
The Viterbi decoder performs maximum likelihood
Furthermore, the Si2109 and Si2110 have an on-chip
estimation of convolutional codes in compliance with
DVB-S and DSS standards. The decoder is capable of
detecting code rate, puncturing pattern phase, 90°
phase rotation, and I/Q interchange. Supported code
rates are listed in Table 14
2
blindscan accelerator. An I C bus interface is used to
configure and monitor all internal parameters.
5.1. Tuner
The tuner is designed to accept RF signals within a 950
to 2150 MHz frequency range. The inputs are matched
to a 75 Ω coaxial cable in a single-ended configuration.
The tuner block consists of a low-noise amplifier (LNA),
variable gain attenuators, a local oscillator, quadrature
downconverters, and anti-aliasing filters. The LNA and
variable gain stages provide balance between the noise
figure and linearity characteristics of the system. When
all gain stages are combined, the device provides more
than 80 dB of gain range. The desired tuning frequency
can be adjusted in intervals of 12.2 kHz, without the aid
of external varactors, using a unique two-stage tuning
algorithm that is supplied with the software driver. The
rapid settling time of the local oscillator improves
channel acquisition and switching performance. The
PLL loop filter has been completely integrated into the
Table 14. Viterbi Code Rates
DVB-S
1/2
DSS
1/2
2/3
—
2/3
3/4
5/6
—
—
6/7
—
7/8
device resulting in low tuner phase noise, improved The device allows monitoring of the Viterbi bit-error rate
spurious response, and reduced BOM cost. An external (BER) over a finite or infinite measurement window.
20 MHz crystal unit generates the reference frequency
for the system.
5.3.2. Convolutional De-Interleaver
The deinterleaver disassembles the Reed-Solomon
(RS) code words, which were interleaved by the
modulator, to provide better resilience against burst
errors. The Si2107/08/09/10 performs deinterleaving
according to DVB-S and DSS standards.
5.2. Demodulator
The demodulator supports QPSK and BPSK
demodulation of channels between 1 to 45 Mbaud. It
incorporates the following functional blocks: analog-to-
digital converters (ADCs), dc notch filters, I/Q imbalance
5.3.3. Reed-Solomon Decoder
corrector, decimation filters, matched filters, equalizer, The Si2107/08/09/10 supports RS codes in compliance
digital automatic gain controls, and a soft-decision with DVB-S and DSS specifications. Both standards use
decoder. The demodulator supports rapid channel a shortened Reed-Solomon code, which can correct up
acquisition using an advanced carrier offset estimation to eight byte errors per information packet. DVB-S
algorithm. When combined with the Si2109/10’s blind utilizes 204 byte codes. DSS utilizes 146 byte codes.
scanning capabilities, the device becomes an ideal
Preliminary Rev. 0.81
20
Si2107/08/09/10
The device allows monitoring of correctable bit,
correctable byte, and uncorrectable packet errors over a
finite or infinite measurement window. The device also
includes a total BER monitor, which compares received
data from a modulated PRBS sequence against the
same sequence generated from an on-chip PRBS
generator.
5.6. On-Chip LNB DC-DC Step-Up
Controller (Si2108/10 Only)
Next to the LNB message signaling controller, the
device also integrates the LNB supply regulator
controller. The supported LNB supply regulator
architecture consists of a step-up dc-dc (boost)
converter followed by an efficient filter, linefeed, and
DiSEqC transmit/receive circuit, which implements a
very power-efficient LNB supply solution. This facilitates
a complete LNB supply circuit with only a minimal
number of external components.
5.3.4. Energy-Dispersal Descrambler
The descrambler removes the energy dispersal
scrambling introduced by the DVB-S process. The
descrambler is automatically bypassed in DSS mode.
5.4. On-Chip Blindscan Controller: Quick-
Scan (Si2109/10 Only)
5.7. Crystal Oscillator
The crystal oscillator requires a crystal with a resonant
The device includes on-chip QuickScan circuitry to fundamental frequency of 20 MHz to generate the
facilitate extremely fast detection of available satellite reference frequency for the local oscillator. A single
channels. For each valid DVB-S/DSS channel, the crystal can be shared between two devices by utilizing
tuning frequency and symbol rate, which can be stored the master-slave configuration shown in Figure 11.
by the host for subsequent tuning, are determined. On
Si2107/08 devices, the host needs to provide the
channel tuning frequency and symbol rate to the device.
C11
XTAL1
XTAL1
5.5. LNB Signaling Controller
Y1
The device supports several LNB signaling methods
including dc voltage selection, continuous tone, tone
burst, DiSEqC 1.x- and DiSEqC 2.x-compliant
messaging, and several combinations of these to allow
simultaneous operation with legacy tone/burst and
DiSEqC-capable peripherals.
XTAL2
C12
XTOUT
2
Si2107/09 includes the capability to convert I C
signaling commands to signals that interface to an
external LNB supply regulator circuit. In the case of (bi-
directional) DiSEqC operation, the device modulates
(and demodulates) the PWK data to (and from) an
internal message FIFO, which the host uses to write
(and read) DiSEqC messages. In the case of
transmission, the device can generate either the 22 kHz
tone burst directly or generate a tone envelope for when
an external LNB supply controller is used, which
includes the 22 kHz oscillator.
Figure 11. Master-Slave Crystal Sharing
Preliminary Rev. 0.81
21
Si2107/08/09/10
All signals on the MPEG-TS output interface can be
individually tri-stated using bits TSE_OE, TSV_OE,
6. Operational Description
The following sections discuss the user-programmable TSS_OE, TSC_OE, and TSD_OE.
functionality offered by the corresponding register map
Transport stream data can be output in a parallel byte-
sections. Refer to Table 19, “Register Summary,” on
page 35 and detailed register descriptions starting on
page 39.
wide mode or a serial bit-wide mode for system-level
flexibility. Selection of the interface mode is controlled
via the TSM bit. In serial mode, data is output on
TS_DATA[0] while TS_DATA[7:1] are held low. The
direction of the serial data stream may be programmed
to output in an MSB or LSB first direction using the
TSDF bit. Parity data may be optionally zeroed by
setting the TSPG bit. To support board-level timing
modifications, the data stream may be delayed by
setting TSDD.
6.1. System Configuration
The MPEG Transport Stream (TS) output interface
carries the decoded satellite data to external devices for
further processing. Both DVB-S and DSS receiver
modes and associated output data packet formats are
supported. Mode selection is controlled via the system
mode register, SYSM. QPSK or BPSK demodulation is
set via the modulation type (MOD) register.
The transport stream clock can be programmed such
that data is transitioning on its rising or falling edge
using the TSCE bit. In both serial and parallel mode, the
transport stream clock mode bit, TSCM, can be used to
select either a gapped or continuous clock mode. In the
gapped mode, the clock is active only when data is
being output. For this, parity information is not
considered data when the TSPG is set to output zero
data during parity. In the continuous mode, the clock
runs without regard to data being output, and the user
will use TS_VAL as a data strobe. To support board-
level timing modifications, the clock stream may be
delayed by register bit TSCD.
The MPEG-TS output interface consists of the following
output pins:
ꢀ TS_DATA[7:0]
ꢀ TS_CLK
Data
Clock
ꢀ TS_SYNC
ꢀ TS_VAL
Sync/Frame Start Indicator
Valid Data Indicator
Uncorrectable Packet Error
ꢀ TS_ERR
The start of a TS frame is indicated by the TS_SYNC
signal. The TS_SYNC signal is a pulse that is active
during the sync byte in a DVB-S frame or during the first
byte of a DSS frame and is active only while TS
synchronization exists. In serial mode, the TS_SYNC
pulse can be programmed to be active for the whole
byte, or the first bit only, by setting the TSSL bit. The
polarity of the TS_SYNC pulse can be programmed to
be either active high or active low using the TSSP bit.
In serial mode, the transport stream clock rate range is
determined by the TSSCR register. The exact rate is
determined during the acquisition process. The range
that minimizes the difference between the effective
transport stream data rate and the clock rate should be
chosen. The recommended settings are listed in
Table 15.
The TS_VAL output is used to indicate when valid data
is present. TS_VAL is active during the MPEG-TS frame
packet data and inactive while parity data is being
output or when there is no TS synchronization. The
polarity of the TS_VAL output can be programmed to be
active high or active low using the TSVP bit.
Table 15. Serial MPEG-TS Clock Frequency
TSSCR
00
Baud Rate
40–50 Mbaud
30–40 Mbaud
19–30 Mbaud
1–19 Mbaud
Serial Clock Rate
80–88.5 MHz
The TS_ERR output indicates that an uncorrectable
error has been detected in the RS decoding stage and
that the current TS data packet contains uncorrectable
errors. The TS_ERR output is active during the entire
erred TS frame. The polarity of TS_ERR can be
programmed to be active high or active low using the
TSEP bit.
01
76.8–82.8 MHz
54.9–59.2 MHz
35–37.7 MHz
10
11
Figure 12 illustrates parallel data modes. Figure 13
illustrates serial data modes.
Preliminary Rev. 0.81
22
Si2107/08/09/10
Continuous Parallel Data Mode
TS_CLK, rising edge
TS_DATA[7:0]
TS1 (sync)
TS188
TS2
TS1 (sync)
TS2
RS1
TS_SYNC active high
TS_VAL active high
TS_ERR active high
Gapped Parallel Data Mode
clk, falling edge+
gapped
data, parity
TS1 (sync)
TS2
TS188
RS1
TS1 (sync)
TS2
start, active high
valid, active high
fail, active high
Figure 12. MPEG-TS Parallel Mode
Continuous Serial Data Mode
TS_CLK rising edge
TS1 (sync)
TS2
TS188
RS1
TS1 (sync)
TS2
TS_DATA[0]
TS_SYNC, active low/1-bit wide
TS_VAL active low
TS_ERR, active low
Gapped Serial Data Mode
TS_CLK falling edge/ gapped
TS1 (sync)
RS1
TS2
TS188
TS2
TS1 (sync)
TS_DATA[0]
TS_SYNC active high
TS_VAL active high
TS_ERR active high
Figure 13. MPEG-TS Serial Modes
The device has one output pin (pin 30), which can be bit, RS_BP, and the convolutional de-interleaver bypass
configured as either a receiver lock indicator, general bit, DI_BP. The use of these bypass options is defined
purpose output, or interrupt output, using the pin select for the implementation of a BER test on a known
register, PSEL. The receiver lock indicator provides a modulated PRBS data sequence as explained later in
signal output for register bit RCVL. The general purpose "6.5. Channel Decoder" on page 27.
output reflects the polarity of register bit GPO. The
6.2. Interrupts
interrupt output is discussed further in “6.2. Interrupts”.
The device is equipped with several sticky interrupt bits
The user can configure the device such that
to provide precise event tracking and monitoring.
components of the channel decoder are bypassed. This
2
is controlled by the energy-dispersal descrambler Next to interrupts being signaled via the I C register
bypass bit, DS_BP, the Reed-Solomon decoder bypass map, the user can program one of the device terminals
Preliminary Rev. 0.81
23
Si2107/08/09/10
(INT) as a dedicated interrupt pin via the pin select active high or active low using the interrupt polarity bit,
register bit, PSEL. The device contains an extensive INTP. The interrupt signal type can be configured to be
collection of interrupt sources that can be individually CMOS output or open-drain/source output using the
masked from the INT pin using the corresponding interrupt type bit, INTT.
interrupt enable register bits, labeled with suffix “_E”.
Interrupt bits are set by the device to 1 when an
Thus, the INT output is a logical-OR of all enabled
interrupt occurs. The host clears an interrupt bit by
interrupts. Generation of the channel interrupt on pin
writing a 1 again, at which time the device resets the
INT can be masked off by using the interrupt enable bit,
interrupt bit to zero. Table 16 illustrates the interrupt
INT_EN. Note that interrupt reporting in the register
sources and their associated status, enable, and
map is not affected by INT_EN.
interrupt bits.
The interrupt signal polarity can be configured to be
Table 16. Events, Interrupts, and Status Bits
Event
Interrupt Bit
RCVL_I
Enable Bit
RCVL_E
RCVU_E
AGCL_E
Status Bit
RCVL (0 –>1)
RCVL (1 –> 0)
AGCL (0 –> 1)
AGCF (0->1)
AGCTS (0 –> 1)
CEL (0 –> 1)
CEF(0->1)
Receiver lock
Receiver unlock
AGC lock
RCVU_I
AGCL_I
AGC failure
AGC threshold
AGCTS_I
CEL_I
AGCTS_E
CEL_E
Carrier estimation lock
Carrier estimation failure
Symbol rate est. lock
Symbol rate est. failure
Symbol timing lock
SRL (0 –> 1)
SRF (0->1)
STL_I
STU_I
STL_E
STU_E
CRL_E
CRU_E
VTL_E
STL (0 –> 1)
STL (1 –> 0)
CRL (0 –> 1)
CRL (1 –> 0)
VTL (0 –> 1)
VTL (1 –> 0)
FSL (0 –> 1)
FSL (1 –> 0)
AQF (0 –> 1)
Symbol timing unlock
Carrier recovery lock
Carrier recovery unlock
Viterbi lock
CRL_I
CRU_I
VTL_I
Viterbi unlock
VTU_I
VTU_E
FSL_E
Frame synchronizer lock
Frame synchronizer unlock
Acquisition fail
FSL_I
FSU_I
FSU_E
AQF_E
CN_E
AQF_I
CN_I
C/N measurement complete
Viterbi BER measurement complete
RS measurement complete
Message FIFO empty
Message FIFO full
VTER_I
RSER_I
FE_I
VTER_E
RSER_E
FE_E
FF_I
FF_E
Message received
MSGR_I
MSGPE_I
MSGTO_I
SCD_I
OCD_I
BSDO_I
BSDA_I
MSGR_E
MSGPE_E
MSGTO_E
SCD_E
OCD_E
BSDO_E
BSDA_E
Message parity error
Message receive timeout
Short-circuit detect
Over current detect
Blindscan done
BSDO
BSDA
Blindscan data ready
Preliminary Rev. 0.81
24
Si2107/08/09/10
6.3. Receiver Status
Acquisition Start
During receive operation, the host can retrieve
information on the status of AGC lock (AGCL), carrier
estimation lock (CEL), symbol rate estimation lock
(SRL), symbol timing lock (STL), carrier recovery lock
(CRL), Viterbi decoder lock (VTL), frame sync lock
(FSL), and overall receiver lock (RCVL).
Calibration
done
LO Tuning
done
During channel acquisition, the host can retrieve
information on error conditions due to: AGC search
(AGCF), carrier estimation (CEF), symbol rate search
(SRF), symbol timing search (STF), carrier recovery
search (CRF), Viterbi code rate search (VTF), frame
sync search (FSF), and overall receiver acquisition
(AQF),
Analog AGC Search
done
Stage fail
Stage fail
CFO Estimation1
lock
6.4. Tuning Control
Symbol Rate Estimation1
Stage fail but
The Si2107/08/09/10 utilizes a unique two-stage tuning
algorithm to provide optimal RF reception. The input
signal is first mixed down to a low-IF frequency by a
coarse tuning stage and then down to baseband by a
fine-tune mixer. The user programs both coarse and
fine-tuning frequencies using the CTF and FTF
registers.
Stage fail
lock
STL is locked
Symbol Timing Loop1
Stage fail
and STL
unlocked
lock
Carrier Frequency Loop1
An algorithm (supplied with the reference software
driver) is used to automatically calculate the required
values. As part of the tuning process, the sample rate,
fs, should also be programmed via the ADCSR register.
Values between 192 and 207 MHz are supported. An
algorithm is supplied with the reference software driver
to automatically select the optimal sampling rate.
Stage fail
Stage fail
Viterbi Search2
Frame Search2
Receiver locked
6.4.1. Automatic Acquisition
The receiver acquisition sequence consists of the
following stages: Analog AGC Search, Carrier Offset
Estimation, Symbol Rate Estimation, Symbol Timing
Recovery, Carrier Recovery, Viterbi Search, and Frame
Synchronization. For the receiver to lock, each stage
must run to completion or declare lock as shown in
Figure 14. If a given stage is unable to achieve lock
1. Acquisition fail if stage fails n times in a row.
2. Acquisition fail if stage completes parameter range
without locking.
Figure 14. Acquisition Sequence (Symbol Rate
Estimation Available on Si2109/10 Only)
6.4.2. Carrier Offset Estimation
after exhausting
a
parameter search range or
The desired carrier frequency may be offset from its
nominal position due to the imperfections and
temperature dependencies of the LNB. The carrier
offset estimator uses a search procedure to identify,
track, and remove this frequency offset from the system.
Carrier offset estimation supports two modes: legacy
mode and QuickLock. QuickLock features decreased
search times and enhanced search ranges. Silicon
Laboratories highly recommends the use of Quicklock
exceeding the timeout period, it asserts a fail signal.
To initiate the acquisition sequence, the user should
program the acquisition start bit, AQS. All search
parameters must be specified before initiating the
acquisition. Upon completion of the acquisition
sequence, the AQS bit is automatically cleared. The
acquisition sequence can be aborted at any time by
clearing the AQS bit.
The status of the acquisition sequence can be mode. Legacy mode is supported for backwards
monitored via the registers in the receiver status register compatibility with revision C of Si2107/08.
map section. A successful acquisition is reported by the
The mode selection is programmed with the COEMS
assertion of the receiver lock bit, RCVL. A failed
bit.
acquisition is reported by the assertion of the acquisition
fail bit, AQF.
Preliminary Rev. 0.81
25
Si2107/08/09/10
In legacy mode, seven different carrier offset estimation incoming data signal. When lock is achieved, the
search range scans can be programmed from 0.10 to symbol timing loop lock indicator, STL, is asserted. If
~6.0 MHz with register CESR. This mode locates symbol timing lock is not achieved within a predefined
frequency offsets when the carrier falls within the offset timeout period, the device declares symbol timing loop
search range. Smaller search ranges result in faster failure by asserting the STF bit. The symbol timing
search times.
recovery loop commences under the control of the
acquisition sequencer.
In QuickLock mode, an eighth carrier offset estimation
search range is added. Ranges from 0.10 to ~12.0 MHz 6.4.5. Automatic Fade Recovery
can be programmed with register CESR. QuickLock
The device is designed to automatically recover lock in
mode locates frequency offsets when the 3dB
bandwidth of the channel falls within the offset search
range. When the search range is less than the channel
bandwidth, QuickLock search times further decrease.
When using QuickLock, set the Inband Power
Threshold, 2 dB Bandwidth Threshold, and 3 dB
Bandwidth Threshold registers to the QuickLock
recommended default values before initiating an
acquisition. Refer to Silicon Laboratories Application
the event of a fade condition. Fade recovery is
performed when any stage loses synchronization after
receiver lock has been achieved. It is assumed that
symbol rate, code rate, and puncturing pattern have not
changed; so, these parameters remain fixed during the
attempted reacquisition. The fade recovery sequence is
shown in Figure 15.
The fade recovery sequence continues until either
receiver lock is achieved or a new acquisition is
initiated.
Note
“AN298:
Si2107/08/09/10
Application
Programming Interface Example Software" for the
recommended default values. The recommended
values are documented in the Signal Acquisition section
of the application note.
Calibration
LO Tuning
When carrier offset estimation is complete, the CEL bit
is asserted. If an error is detected during carrier offset
estimation, the CEF bit is set. Carrier offset estimation
commences under the control of the acquisition
sequencer.
Analog AGC Search
After the completion of a search, the estimated carrier
offset is stored in the carrier frequency error register,
CFER. If no signal is found, the CEF bit is asserted. The
value contained in CFER may be optionally transferred
to the CFO register to adjust the search center
frequency and permit the utilization of a smaller search
range for subsequent acquisitions. This relationship can
be expressed by the following equation:
Fail
Done
CFO Estimation
Done
Unlock
Symbol Timing Loop
lock
Unlock
Unlock
fs
215
--------
Carrier Frequency Loop
Search center frequency = fdesired + CFO ×
Hz
lock
6.4.3. Carrier Recovery Loop
Viterbi Search
(Limited)
The carrier recovery loop is responsible for acquiring
frequency and phase lock to the incoming signal. When
lock is achieved, the carrier recovery lock indicator,
CRL, is asserted. If carrier recovery lock is not achieved
within a predefined timeout period, the device declares
carrier recovery failure by asserting the CRF bit. The
carrier recovery loop commences under the control of
the acquisition sequencer.
Unlock
Unlock
lock
Frame Search
lock
Receiver locked
6.4.4. Symbol Timing Loop
Figure 15. Fade Recovery Sequence
The symbol timing recovery loop is responsible for
acquiring and tracking the symbol timing of the
Preliminary Rev. 0.81
26
Si2107/08/09/10
6.4.6. C/N Estimator
6.5.3. Reed-Solomon Error Monitor
A carrier-to-noise estimator is provided to aid in satellite The Reed-Solomon error monitor is capable of counting
antenna positioning. The C/N measurement mode bit, bit, byte, and uncorrectable packet errors. The error
CNM, controls whether the count is performed over a type to be counted is controlled by the Reed-Solomon
fixed-length or infinite window. With a fixed-length error type register, RSERT. The Reed-Solomon error
window, the window size is defined by register CNW. mode bit, RSERM, controls whether the count is to be
Measurements are stored in a 16-bit saturating register, performed over a fixed length or infinite window. The
CNL. Setting the C/N estimator start bit, CNS clears the window size is defined by RSERW. The BER count is
CNL register and initiates the C/N measurement. When stored in a 16-bit saturating register, RSERC. Setting
operating in the finite window mode, the CNS bit is the RS BER measurement start bit, RSERS, clears the
automatically cleared when the measurement is RSERC register and initiates the measurement. When
complete. The CNS bit must be cleared manually in the operating in the finite window mode, the RSERS bit is
infinite mode to stop the count. An external lookup table automatically cleared when the measurement is
is used to translate the measurement into a C/N complete. The RSERS bit must be cleared manually in
estimate for a given setting of the C/N threshold, CNET, the infinite mode, to stop the count.
and a given digital AGC setting.
6.5.4. PRBS BER Tester
To facilitate in-system pseudo random bit sequence
(PRBS) BER testing, the device provides the ability to
6.5. Channel Decoder
6.5.1. Viterbi Decoder
synchronize and track test sequences contained in the
The Viterbi decoder performs maximum likelihood
payload (i.e. not SYNC bytes) of the MPEG data
estimation of convolutional codes in compliance with
stream. The user can define the payload of each TS
DVB-S and DSS standards. When lock is achieved, the
packet to exclude a number of header bytes, as set by
Viterbi lock indicator, VTL, is asserted. If Viterbi lock is
PRBS_HEADER_SIZE,
not achieved after exhausting the specified parameter
A PRBS test pattern must be encoded, modulated, and
space, the device declares Viterbi search failure by
injected into the channel to be monitored. The device
asserting the VTF bit. The Viterbi search commences
supports a PRBS 223 - 1 bits long described by the
under the control of the acquisition sequencer.
following polynomial:
The device can be programmed to attempt to
automatically acquire Viterbi lock using all, one, or a
G(x) = x23 + x18 + 1
subset of the supported code rates using the VTCS
To enable PRBS testing, the Reed-Solomon error type
register.
register, RSERT, must be appropriately programmed.
If lock is achieved, the status of the search, including
After the device has synchronized to the incoming
code rate, puncturing pattern phase, 90-degree phase
PRBS test pattern, as indicated by PRBS_SYNC, errors
rotation, and I/Q swap, can be monitored in the Viterbi
will be reported in the RSERC register.
search status registers, VTRS, VTPS, and VTIQS.
Measurements can be performed at the output of the
Viterbi or Reed-Solomon decoder. To record errors at
6.5.2. Viterbi BER Estimator
The Viterbi BER estimator measures the frequency of
bit errors at the input of the Viterbi decoder. The Viterbi
BER mode bit, VTERM, controls whether the count is to
be performed over a fixed length or infinite window. The
window size is defined by VTERW. The BER count is
stored in a 16-bit saturating register, VTERC. Setting
the Viterbi BER measurement start bit, VTERS, will
clear the VTERC register and initiate the measurement.
When operating in the finite window mode, the VTERS
bit will automatically be cleared when the measurement
is complete. The VTERS bit must be cleared manually
in the infinite mode to stop the count.
the output of the Viterbi decoder, the Reed-Solomon
decoder and interleaver must be bypassed by setting
RS_BP and DI_BP in the “System Configuration”
section of the register map. To record errors at the
output of the Reed-Solomon block, the RS_BP bit must
be cleared.
6.5.5. Frame Synchronizer
The output of the Viterbi decoder is aligned into bytes by
detecting sync patterns within the data stream. In DVB-
S systems, the sync byte, 47h, occurs during the first
byte of a 204 byte RS code block. In DSS systems, a
sync byte, 1Dh, is appended to the beginning of each
RS encoded 146-byte block, resulting in 147-byte RS
code blocks. In DSS mode, sync bytes are discarded
before the byte stream is output to subsequent
decoding stages. When lock is achieved, the frame
Preliminary Rev. 0.81
27
Si2107/08/09/10
synchronization lock bit, FSL, is asserted. If lock is not frequency can be described using the following
achieved, the frame synchronizer fail bit, FSF, is equation, where fs equals the ADC sampling rate,
asserted.
ADCSR.
The frame synchronizer commences under the control
of the acquisition sequencer.
fs
-------------------
AGCW
AGC measurement frequency =
Hz
Following frame synchronization lock, the device
examines the byte stream for a possible 180-degree When gain adjustments are made, the device allows up
phase shift. If an inversion is detected, data are inverted to 100 µs for the gain changes to settle before
prior to being output.
beginning the next measurement.
To facilitate a rapid initial acquisition, Si2107/08/09/10
includes an acquisition mode wherein the measurement
window size is reduced by a factor of 64 when
compared to the normal tracking mode.
6.6. Automatic Gain Control
The Si2107/08/09/10 is equipped with the ability to
adjust signal levels via an automatic gain control (AGC)
loop. This ensures that the noise and linearity
characteristics of the signal path are optimized at all
times. AGC settings can be set at 4 points in the analog
signal chain and 2 points in the digital signal chain.
During the AGC search, the device is in acquisition
mode, and the gain is adjusted until the measured
signal power crosses the desired threshold or a limit is
reached. If the signal power crosses the threshold
before reaching a limit, the search completes, and the
6.6.1. Analog AGC
System gain is distributed into four independent stages AGCL bit is asserted. If a gain limit is reached, the
as shown in Figure 16. The gain range of all stages device asserts both the AGCL bit and the AGCF bit.
combined is over 80 dB. When the AGC search
In the normal tracking mode, the device continuously
completes, the AGCL bit is asserted. If an error is
measures the input signal power according to the AGC
encountered during the AGC search, the AGCF bit is
measurement window size. If the absolute value of the
also set. The AGC search commences under the
difference between the AGCTH and AGCPWR exceeds
the value of the AGC tracking threshold, AGCTR, the
control of the acquisition sequencer.
The AGC loop works to automatically adjust the gain of AGC loop adjusts gain settings until the AGCPWR level
each stage to minimize the error between a measured matches AGCTH.
signal power and a desired output level. Signal power is
The AGC gain offset register, AGCO, provides the
measured at the output of the ADC using an internal
ability to apply a static gain offset to the input channel.
rms power calculator. The result is stored in a 7-bit
Silicon Laboratories will provide the recommended
saturating register, AGCPWR. The desired output level
values for this register. It is possible to read out the
is stored in the AGC threshold register, AGCTH. Signal
instantaneous settings of each of the four VGAs from
power measurements occur at a frequency dictated by
the AGC<n>, <n = 1..4>, registers.
the AGC measurement window size, AGCW. This
LPF
OFFSET
LNA
VGA1
VGA2
MIXER
A/D
rms calculator
AGC
AGC Threshold
Figure 16. Analog AGC Control Loop
Preliminary Rev. 0.81
28
Si2107/08/09/10
6.6.2. Digital AGC
When an external LNB supply regulator is used, the
DCS pin is driven high or low depending on the
selection of high or low voltage.
Downstream of the analog VGAs, after A/D conversion
of the signal, there are two points at which the digital
gain can be programmed. Digital AGC1 is used to 6.7.2. Tone Generation
change signal power after removal of adjacent channels
by the (digital) anti-aliasing filter.
Tone-related information is communicated to external
devices via the TGEN pin. The tone format select bit,
By default, DAGC1 is enabled and periodically adjusts TFS, specifies whether the output of TGEN is an
the gain of the I & Q data streams based on a internally-generated tone or a tone envelope. The
comparison of the measured complex RMS level and a frequency of the internal tone generator is governed by
target value. The target value can be selected with the the following equation:
DAGC1T register. Two levels are provided to allow
operation with additional headroom for signal peaks
during signal acquisition. The gain function of DAGC1
can be disabled using DAGC1_EN; then, no gain is
applied to I & Q data streams. The signal measurement
and gain adjustment normally operate continuously,
allowing the gain to track the input level. The
measurement window can be adjusted by register
DAGC1W. The automatic updating of the gain can be
frozen by register bit DAGC1HOLD. This holds the gain
to the last setting. The value of the gain can be read
from the DAGC1 register. It is possible to override the
internal AGC algorithm and provide host-based control
of AGC1 by appropriately programming register bit
DAGC1HOST.
100
----------------------------------------------------------
MHz
ftone
=
[32 × (TFQ[7:0] + 1)]
Frequencies between 20 and 24 kHz are supported.
The default value of TFQ results in a nominal tone
frequency of 22 kHz. When tone envelope output is
selected, a high signal on TGEN corresponds to "tone
on" while a low signal corresponds to "tone off." When
operating in the “Manual LNB messaging mode”, the TT
bit directly controls the output of the tone or tone
envelope.
6.7.2.1. Continuous Tone
A continuous tone is typically used to select between
the high and low band of an incoming satellite signal.
The LNBCT bit can be set to one to generate a
continuous tone.
Digital AGC2 (DAGC2) is intended to optimally scale the
soft decision outputs of the demodulator prior to Viterbi
decoding. This allows it to compensate for signal level
variations after matched filtering and equalization.
Normally, operation is continuous, but tracking can be
disabled using register bit DAGC2_TDIS. This holds the
gain to the last setting.
6.7.2.2. Tone Burst
The tone burst signaling method can be used to
facilitate the control of a simple two-way switch. Two
types of tone burst are available, as shown in Figure 17.
An unmodulated tone burst persists for 12.5 ms. A
modulated tone burst lasts for the same duration but
consists of a sequence of nine 0.5 ms pulses and 1 ms
gaps. Tone burst selection is controlled via the LNBB
bit. The tone burst command can optionally be disabled
to support systems that do not use tone burst signaling
by setting the burst disable bit, BRST_DS, to one. This
disables the tone/burst generation as part of the
DiSEqC signaling sequence when the device uses
“Automatic LNB messaging mode” as described below.
During AGC operation, the average power of the signal
is compared to a threshold set by register DAGC2T. The
signal power is measured over a finite window specified
by DAGC2W. The gain applied to the signal to make the
input match the programmed threshold can be read
from register DAGC2GA.
6.7. LNB Signaling Controller
All device versions provide LNB signaling capability.
The device supports several LNB signaling methods
including dc voltage selection, continuous tone, tone
burst, DiSEqC 1.x- and DiSEqC 2.x-compliant
messaging. A description of each method follows.
'0' Tone Burst (Satellite A)
Envelope
Tone
'1' Tone Burst (Satellite B)
Envelope
6.7.1. DC Voltage Selection
A constant dc voltage of 18 or 13 V is typically used to
switch the LNB between horizontal and vertical polarity
or clockwise and counterclockwise polarization. The
LNBV bit is used to select the desired voltage.
Tone
12.5 ms
Figure 17. Tone Burst Modulation
Preliminary Rev. 0.81
29
Si2107/08/09/10
6.7.3. DiSEqC™
6.7.3.2. DiSEqC 2.x Two-Way Communication
The DiSEqC signaling method extends the functionality Two-way communication is supported via DiSEqC 2.x-
of the legacy 22 kHz tone by superimposing a compliant messages. When the seventh bit in the
command protocol and adding an optional return framing byte of an outgoing message is set to 1, the
channel. A DiSEqC command normally consists of a device anticipates a response and monitors the line for
framing byte, an address byte, a command byte, and, up to 150 ms for an incoming message. If no message
optionally, one or more data bytes. This format is is detected during the 150 ms monitoring period, the
illustrated in Figure 18.
MSGTO bit is asserted to indicate the time-out
condition. A DiSEqC reply message typically consists of
a single framing byte and optionally one or more data
bytes as shown in Figure 20.
P
P
FRAMING
ADDRESS
P
P
COMMAND
DATA
Figure 18. DiSEqC Message Format
The length of a message is specified by MSGL. When
the message length is set to one byte, the message is
modulated using tone burst modulation. When the
message length is set to two or more bytes, the
message is modulated using DiSEqC-compliant
modulation, and the odd parity bit is automatically
added. The DiSEqC modulation scheme is illustrated in
Figure 19.
DATA
DATA
FRAMING
P
P
P
Figure 20. DiSEqC Reply Format
When a complete message has been received (one or
more bytes followed by 4 ms of silence), the MSGR bit
is asserted. Should parity errors exist in the received
message, the MSGPE flag is also asserted. If the
received message is longer than 6 bytes, the FIFO full
bit, FF, is asserted to indicate that a byte has been
written to FIFO6. The LNB control module writes the
next byte to FIFO1. The length of the received message
is recorded in the MSGRL register.
'1' Data Bit
'0' Data Bit
6.7.4. LNB Signaling Modes
The LNB signaling modes are described in the following
sections.
1.0 ms
0.5 ms
1.0 ms
0.5 ms
6.7.4.1. Automatic LNB Messaging Mode
Figure 19. DiSEqC Compliant Modulation
The Si2107/08/09/10 LNB Signaling Controller can fully
manage the generation and sequencing of all LNB
commands. The device is configured in this mode by
appropriately programming the LNB Messaging mode
register, LNBM. To initiate a message sequence, the
user should first program LNB voltage selection (LNBV),
continuous tone enable (LNBCT), tone burst type
(LNBB), and DiSEqC message parameters (MMSG,
MSGL, and FIFO1..6). Subsequently, the LNB
sequence start bit, LNBS, must be set to start the
automated transmission sequence. The device
automatically allocates the required delays between
each signaling method. Prior dc voltage levels and
continuous tones, if present, persist until the sequence
is initiated. A typical sequence is shown in Figure 21.
6.7.3.1. DiSEqC 1.x One-Way Communication
Messages are programmed directly into the device
using a message FIFO that consists of six byte wide
registers, FIFO1–6. The messages must be written in a
first-in-first-out manner such that the first byte of a
message is stored in FIFO1; the second byte is stored
in FIFO2, and so on. If messages are longer than six
bytes, the device asserts the FIFO empty indicator, FE,
as soon as the sixth byte has been read. The LNB
control module then takes its next byte from FIFO1 and
continues the process. The message length must also
be reprogrammed to indicate how many more bytes
remain to be sent. The interval between FIFO reads is
typically 13.5 ms.
Multiple messages can be sent in a sequential manner
by setting the MMSG bit. When this bit is set, the LNB
control module delays continuous tone and tone burst
commands until all messages in the sequence have
been sent. After the current message is transmitted, the
MMSG bit is automatically cleared. The tone burst can
be disabled as part of this sequence depending on the
setting of BRST_DS.
To support cascaded DiSEqC devices, it may be
necessary to repeat commands. Repeated commands
should be separated by at least 100 ms to ensure that
the far-end device is connected to the signaling path. To
facilitate the required 100 ms delay, a four byte
command can be inserted between repeated
commands.
Preliminary Rev. 0.81
30
Si2107/08/09/10
When the sequence has completed, the device clears modulation for a '00h' byte), no tone is generated. Also,
the LNB sequence start bit, LNBS, automatically. Note the device does not expect a reply if FIFO1 is
that, when operating in this mode, the DRC pin is high programmed to FFh; i.e., the assertion of bit7 is not
while transmitting and low while receiving.
considered a request for the peripheral to reply in step-
by-step LNB messaging mode.
6.7.4.2. Step-by-Step LNB Messaging Mode
6.7.4.3. Manual LNB Messaging Mode
By appropriately programming the LNB Messaging
Mode register, LNBM, the device allows for individual The manual LNB messaging mode provides the
control of each signaling method by the host. In this maximum level of signaling flexibility but at the expense
mode, the LNB voltage, LNBV, and LNB continuous of increased software interaction. The device is
tone enable, LNBCT, take effect once they are set configured in this mode by appropriately programming
without waiting for the user to set the LNB sequence the LNBM register. The continuous tone, tone burst, and
start bit, LNBS.
messaging controls are not functional in this mode.
When the tone format bit, TFS, is programmed for use
of the internal oscillator, assertion of the TT bit
modulates the output of the internal tone generator on
the TGEN pin, and the TR bit records the envelope of a
tone presented to the TDET pin.
The DiSEqC message uses the LNBS bit to start
transmission and behaves the same as in Automatic
LNB Messaging Mode. However, the guard intervals
between each signaling method (LNB voltage change,
DiSEqC message, tone burst, and continuous tone
resumption) are controlled by the host.
When the tone format select bit, TFS, is programmed to
use an external oscillator, the TT bit directly controls the
output of the TGEN pin, and the TR bit directly reflects
the input of the TDET pin. In this mode, the tone
direction control bit, TDIR, directly controls the output of
the DRC pin.
In this mode, the tone burst should be implemented by
using a 1-byte DiSEqC message of all 0s or all 1s
programmed into FIFO1. The device uses appropriate
modulation for the tone burst; i.e., when FIFO1 is
programmed to 00h (rather than a DiSEqC-compliant
End of continuous
tone (if present)
Change of voltage
(if required)
1st message (no
reply requested)
2nd message
(reply requested)
Reply to 2nd
message
Start of continuous
tone (if present)
Tone Burst
> 15ms
> 25ms
< 150ms
> 15ms
> 15ms
Figure 21. LNB Signaling Sequence
Preliminary Rev. 0.81
31
Si2107/08/09/10
The maximum current draw of the LNB supply can be
set using the IMAX register. The overcurrent threshold
of the LNB supply may be set via the ILIM register. If the
output current exceeds this value, the external LNB
power supply is automatically disabled, and the
overcurrent detect bit, OCD, is asserted. The device
attempts to restore normal operation after 1 s by
supplying power to the line. During the recovery period,
overcurrent detection is disabled for the time specified
by the OLOT register.
6.8. On-Chip LNB DC-DC Step-Up
Controller (Si2108/10 Only)
In addition to the LNB signaling controller present on all
device versions, Si2108 and Si2110 devices contain an
internal supply controller circuit. This internal dc-dc
controller can be enabled via register bit LNB_EN. The
internal circuit requires the connection of an external
circuit with a specified bill-of-materials, and this
combination generates the selected LNB voltage with
superimposed one-way or two-way LNB signaling
communications. Si2108/10 devices include short-
circuit protection, overcurrent protection, and a step-up
dc-dc controller to implement a low-cost LNB power
supply using minimal external components. The
required circuit for DiSEqC1.x operation is illustrated in
Figure 9 on page 14. A circuit for DiSEqC2.x operation
is shown in Figure 6 on page 12.
Short circuit protection circuitry operates in conjunction
with overcurrent detection to rapidly identify short-circuit
conditions. If the output is shorted to ground, the
external LNB power supply is automatically disabled,
and the short-circuit detect bit, SCD, is asserted. The
device attempts to restore normal operation after one
second by supplying power to the line. During the
recovery period, short-circuit detection is disabled for
the time specified by the SLOT register.
When the LNB supply circuit is populated, the Si2108/
10 detects a connection to ground on the ISEN pin via
R10 during reset and configures the LNB pins for dc-dc
converter control instead of providing the interfaces to
an external LNB supply regulator discussed in the
previous section. See Table 17.
The LNB supply circuit is protected from an overvoltage
condition by design. In the event that the LNB supply
circuit is accidentally connected to a voltage source
greater than the intended output voltage, it remains
operational. The LNB supply circuit resumes normal
operation when the connection to the external voltage
source has been removed.
Table 17. LNB Pin Configuration
Pin
LNB Supply Circuit
Connected Unconnected
6.9. On-Chip Blindscan Controller:
QuickScan (Si2109/10 Only)
7
10
9
VSEN
LNB2
ISEN
LNB1
PWM
TDET
DRC
NC
QuickScan is comprised of a two stage process: a
blindscan stage and confirmation stage. It is an
automated process whereby the minimum and
maximum RF frequency and symbol rate limits are
entered in the following registers BS_FMIN, BS_FMAX,
SRMIN, and SRMAX. After blindscan is completed, the
host may further use the resulting candidate channel
information (channel center frequencies and baud
rates) to try to actually acquire such channels by locking
the receiver to them. Further information such as C/N,
BER, channel program IDs, and etc. can be obtained
once the receiver locks to a candidate channel. Through
this confirmation process, any falsely identified
channels can be rejected.
8
TGEN
DCS
12
The LNB supply controller is disabled by default. To use
the supply, it must be enabled by setting the LNB enable
bit, LNB_EN. If the LNB supply circuit is connected, the
TFS bit is ignored; the internal LNB supply controller
uses its internal oscillator to generate the 22 kHz tone.
The TFQ setting can still be used to modify the nominal
frequency as explained earlier.
Selection of high or low voltage outputs the
corresponding PWM control signal for the boost
converter. To compensate for long cable lengths, a 1 V
boost can be applied to both levels by setting the COMP
bit.
6.9.1. Programming Sequence
If QuickScan is conducted whereby the symbol rate
search range is above 12.5 MBaud (for example
SRMIN = 2 MBaud and SRMAX = 20 MBaud) Silicon
Laboratories recommends that blindscan is performed
twice to ensure the most favorable estimates of channel
The nominal level of both the low- and high-output
voltages can be further fine-tuned using the VLOW and frequencies and symbol rates.
VHIGH registers. Register bit LNBV selects whether to
output high or low dc voltage to the LNB. During
operation, the voltage level of the line can be monitored
via the VMON register.
The programming sequence is as follows:
1. Program the frequency range (BS_FMIN, BS_FMAX) and
symbol rate range (SRMIN, SRMAX) values over which to
perform blindscan.
Preliminary Rev. 0.81
32
Si2107/08/09/10
a. Default values
i. SRMIN = 0 MBaud
Important: These bits should be returned to their
default settings (allowing host control) if the user wants
to tune to individual channels following blindscan for
single channel acquisition.
ii. SRMAX = 0 MBaud
iii. BS_FMIN = 825 MHz
iv. BS_MAX= 2087 MHz
4. Set BS_START in the Blind Scan Control Register. This
initiates the blindscan process.
The default values for the minimum and maximum
symbol rates are zero. Enter minimum and maximum
symbol rates.
5. Wait for either BSDA (or interrupt BSDA_I) or BSDO (or
interrupt BSDO_I) to be set.
6. Take the following actions depending on which condition is
present:
Recommended values are SRMIN = 1 MBaud and
SRMAX = 45 MBaud for discovery of all possible DVB-
S channels.
a. When BSDA (or BSDA_I) is set: the device has found
a potential DVB-S or DSS (depending on the part's
operating mode) channel. The host can read out:
2. Program the following registers with the following
parameters.
i. BS_CTF, BS_FTF, CFER, and BS_ADCSR
to determine the channel's RF frequency
from the following formula:
a. LSA Control Register 1. The length of the time
averaging window is set by setting AVG_WIN. The
averaging removes uncorrelated noise from the
spectrum.
RF(MHz) = BS_CTF x 10 + {BS_FTF(decimal) + CFER
(decimal)} x BS_ADCSR
b. Tilt Correction Threshold Register. A correction can be
applied to the spectrum to compensate for "tilts" in the
spectrum due to frequency dependent attenuation
such as poor cables for example.
Note: The registers BS_FTF with a fixed
format of <15,14> and CFER with a fixed
format of <16,15> are 2's complement
numbers which need to be converted into
decimal numbers first.
c. Reference Noise Level Margin Threshold Register.
This sets the power level threshold for the detection of
channels.
ii. SREST to determine the channel's symbol
rate estimate from the following formula:
d. 1 dB Bandwidth Threshold Register. This sets the
tolerance level for determination of the 1 dB
bandwidth for a detected channel.
Symbol Rate (MBaud) = SREST x BS_FS / 2^23
e. 2 dB Bandwidth Threshold Register. This sets the
tolerance level for determination of the 2 dB
bandwidth for a detected channel.
Where BS_FS = BS_ADCSR x 1 MHz
iii. Upon reading these registers, the host
should clear the BSDA & BSDA_I bits. Go
back to Step 6.
f. 3 dB Bandwidth Threshold Register. This sets the
tolerance level for determination of the 3 dB
bandwidth for a detected channel.
b. When BSDO (or BSDO_I) is set: the blindscan
operation is complete within the RF and symbol rate
search ranges. The device automatically clears
BS_START.
g. Inband Power Threshold Register. This sets the
threshold for determining the drop in power in a
detected channel to determine the channel bandwidth.
7. Repeat Steps 1 through 6 with the change in values for the
following parameters if the Symbol Rate search range is
below 12.5 MBaud.
Important: It is highly recommended that the registers
in Step 2 be programmed with default values provided
by Silicon Laboratories. Refer to “AN298: Si2107/08/09/
10 Application Programming Interface Example
Software”, for the recommended values. The values are
documented in the QuickScan section of the application
note. Silicon Laboratories has tested QuickScan under
real world conditions in a number of countries and the
recommended values provide the best performance.
a. Set SRMIN to 12.5 MBaud.
b. Keep SRMAX the same value from the first pass.
c. Set Inband Power Threshold Register to the second
recommended default value.
d. Set 2 dB Bandwidth Threshold Register to the second
recommended default value.
3. Clear the following Host Control Register bits.
a. SR_CTRL_HOST
8. End of blindscan operation. The final set of estimates for
RF center frequencies and associated symbol rates can
be used by the host to lock to the detected channels to
obtain channel information such as Channel ID for
example. Also at this point channels falsely identified
during blindscan can be rejected upon failure to lock.
b. ADCSR_CTRL_HOST
c. CTF_CTRL_HOST
d. FTF_CTRL_HOST
Preliminary Rev. 0.81
33
Si2107/08/09/10
master. During a write, data is sent from the bus master
to the device. The field labeled “DATA (ADR)” must
contain the 8-bit address of the target register. The data
to be transferred to or from the target register must be
placed in the following 8-bit “DATA” field. When the
auto-increment feature is enabled, INC_DS, the target
register address, is automatically incremented for
subsequent data transfers until a STOP condition ends
the operation.
7. I2C Control Interface
2
The I C bus interface is provided for configuration and
monitoring of all internal registers. The Si2107/08/09/10
supports the 7-bit addressing procedure and is capable
of operating at rates up to 400 kbps. Individual data
2
transfers to and from the device are 8-bits. The I C bus
consists of two wires: a serial clock line (SCL) and a
serial data line (SDA). The device always operates as a
bus slave. Read and write operations are performed in
Some registers in the device are larger than the 8-bit
2
2
DATA field permitted by I C. These registers are split
accordance with the I C-bus specification and the
into 8-bit addressable chunks that are uniquely
identified by a positional suffix. The suffix L indicates the
low-byte; the suffix M indicates the middle-byte (for 24-
bit registers only), and the suffix H indicates the high-
byte.
following sequences.
The first byte after the START condition consists of the
slave address (SLAVE ADR, 7-bits) of the target device.
The slave address is configured during a hard reset by
setting the voltage on the ADDR pin. Possible slave
addresses and their corresponding ADDR voltages are
listed in Table 18.
To read a multibyte register as a single unit, the low byte
must be read first. This forces the device to sample and
hold the contents of the remaining bytes until the
multibyte read is complete. If a STOP condition occurs
before the operation is complete, the buffered data is
discarded.
Table 18. I2C Slave Address Selection
Fixed Address
11010
LSBs
00
ADDR Voltage (V)
(pullup)
To write a multibyte register as a single unit, the low
byte must be written first. All bytes must be transferred
to the device before the multibyte value is recorded. If a
STOP condition occurs before the operation is
complete, the buffered data is discarded.
V
3.3
11010
01
2/3 x V ±10%
3.3
11010
10
1/3 x V ±10%
3.3
The slave address consists of a fixed part and a
programmable part. The voltage of the ADDR pin is
used to set the two least significant bits of the address
during device power-up according to the table below.
This enables up to four devices to share the same I C
bus.
11010
11
0 (pulldown)
Four addresses are available, allowing up to four
devices to share the same I C bus. The R/W bit
determines the direction of data transfer. During a read
operation, data is sent from the device to the bus
2
2
Read Operation
S
SLAVE ADR
W
W
A
A
DATA (ADR)
DATA (ADR)
A
A
Sr or P
SLAVE ADR
SLAVE ADR
R
A
A
DATA
A/A
A/A
P
P
n bytes + ack
Write Operation
SLAVE ADR
S
Sr or P
W
DATA
n bytes + ack
Master
Slave
A = Acknowledge
R = Read (1)
S = START condition
P = STOP condition
W= Write (0)
Sr = Repeated START condition
2
Figure 22. I C Interface Protocol
Preliminary Rev. 0.81
34
Si2107/08/09/10
8. Control Registers
The control registers can be divided into three main classes: Initialization, Run-time, and Status. Initialization
registers (“I”) need only be programmed once following device power-up. Run-time registers (“RT”) are the primary
registers for device control. Status registers (“S”) provide device state information. The corresponding category of
each register is indicated in the rightmost column of Table 19.
Unused register bits of a register byte are reserved, Their bit values should not be changed from the default values,
as identified below under the description of each individual register byte.
Table 18 lists all registers available in Si2110; some registers may not be available in other part versions, as
identified below under the description of each individual register byte.
Table 19. Register Summary
I2C
Name
D7
D6
D5
D4
D3
D2
D1
D0
Addr.
System Configuration
Device ID
System Mode
TS Ctrl 1
00h
01h
02h
03h
DEV[3:0]
INC_DS
REV[3:0]
S
I
MOD[1:0]
SYSM[2:0]
TSDF
TSEP
TSVP
TSSP
TSPCS
INTP
TSSL
TSCD
TSCM
TSDD
TSCE
TSPG
TSM
I
TS Ctrl 2
TSSCR[1:0]
I
Pin Ctrl 1
Pin Ctrl 2
Bypass
04h INT_EN
INTT
TSE_OE TSV_OE
TSS_OE
GPO
TSC_OE
TSD_OE
I
05h
06h
PSEL[1:0]
I
DS_BP
CEL_E
RS_BP
DI_BP
I
Interrupts
Int En 1
Int En 2
Int En 3
Int En 4
Int Stat 1
Int Stat 2
Int Stat 3
Int Stat 4
07h RCVL_E
AGCL_E
STL_E
VTU_E
FE_E
CRL_E
FSU_E
FF_E
VTL_E
FSL_E
AQF_E
MSGTO_E
OCD_E
FSL_I
I
I
08h RCVU_E AGCTS_E STU_E
CRU_E
09h
0Ah
CN_E
VTER_E RSER_E MSGPE_E
BSDO_E BSDA_E
MSGR_E
SCD_E
VTL_I
I
I
0Bh RCVL_I
AGCL_I
CEL_I
STU_I
STL_I
VTU_I
FE_I
CRL_I
FSU_I
FF_I
S
S
S
S
0Ch RCVU_I AGCTS_I
CRU_I
AQF_I
0Dh
0Eh
CN_I
VTER_I
BSDO_I
RSER_I MSGPE_I
BSDA_I
MSGR_I
SCD_I
MSGTO_I
OCD_I
Receiver Status
Lock Stat 1
Lock Stat 2
Acq Stat
0Fh
10h
11h
AGCL
AGCF
CEL
CEF
SRL
STL
STF
CRL
CRF
VTL
BSDA
VTF
FSL
BSDO
FSF
S
S
S
RCVL
AQF
SRF
Preliminary Rev. 0.81
35
Si2107/08/09/10
Table 19. Register Summary (Continued)
I2C
Name
D7
D6
D5
D4
D3
D2
D1
D0
Addr.
Tuning Control
Acq Ctrl 1
ADC SR
14h
15h
16h
17h
18h
29h
36h
37h
38h
39h
3Fh
40h
41h
7Ch
7Dh
7Eh
7Fh
AQS
RT
RT
RT
RT
RT
I
ADCSR[7:0]
CTF[7:0]
Coarse Tune
Fine Tune L
Fine Tune H
CE Ctrl
FTF[7:0]
FTF[14:8]
CESR[2:0]
CE Offset L
CE Offset H
CE Err L
CFO[7:0]
CFO[15:8]
CFER[7:0]
CFER[15:8]
SR[7:0]
RT
RT
RT
RT
RT
RT
RT
I
CE Err H
Sym Rate L
Sym Rate M
Sym Rate H
CN Ctrl
SR[15:8]
SR[23:16]
CNS
CNM
CNW[1:0]
CN TH
CNET[7:0]
CNL[7:0]
I
CN L
RT
RT
CN H
CNL[15:8]
Channel Decoder
VT Ctrl 1
VT Ctrl 2
A0h
A2h
A3h
ABh
ACh
B0h
B1h
B2h
B3h
B5h
VTCS[5:0]
VTERM
I
VTERS
VTERW[1:0]
RT
S
VT Stat
VTRS[2:0]
VTPS
VTIQS
VT BER Cnt L
VT BER Cnt H
RS Err Ctrl
RS Err Cnt L
RS Err Cnt H
DS Ctrl
VTERC[7:0]
VTERC[15:8]
RSERM
RT
RT
RT
RT
RT
I
RSERS
RSERW
RSERT[1:0]
RSERC[7:0]
RSERC[15:8]
DST_DS
DSO_DS
PRBS Ctl
PRBS_
START
PRBS_
INVERT
PRBS_
SYNC
PRBS_HEADER_SIZE
RT
36
Preliminary Rev. 0.81
Si2107/08/09/10
Table 19. Register Summary (Continued)
I2C
Name
D7
D6
D5
D4
D3
D2
D1
D0
Addr.
Automatic Gain Control
AGC Ctrl 1
AGC Ctrl 2
AGC 1–2 Gain
AGC 3–4 Gain
AGC TH
23h
24h
25h
26h
27h
28h
75h
76h
77h
78h
79h
7Ah
7Bh
AGCW[1:0]
I
I
AGCTR[3:0]
AGCO[3:0]
AGC2[3:0]
AGC4[3:0]
AGC1[3:0]
AGC3[3:0]
I
I
AGCTH[6:0]
I
AGC PL
AGCPWR[6:0]
S
I
DAGC 1 Ctrl
DAGC1 L
DAGC1_EN
DAGC1W[1:0]
DAGC2[3:0]
DAGC1T DAGC1HOLD DAGC1HOST
DAGC1[7:0]
I
DAGC1 H
DAGC1[15:8]
I
DAGC2 Ctrl
DAGC2 TH
DAGC2Lvl L
DAGC2Lvl H
DAGC2W[1:0]
DAGC2TDIS
I
DAGC2T[7:0]
I
DAGC2GA[7:0]
I
DAGC2GA[15:8]
I
LNB Supply Controller
LNB Ctrl 1
LNB Ctrl 2
LNB Ctrl 3
LNB Ctrl 4
LNB Stat
C0h
C1h
C2h
C3h
C4h
C5h
C6h
C7h
C8h
C9h
CAh
CBh
CCh
CDh
CEh
CFh
LNBS
LNBV
TT
LNBCT
LNBB
MMSG
MSGL[2:0]
TFS
RT
RT
RT
RT
S
LNBM[1:0]
BRST_DS
TDIR
FE
TR
TFQ[7:0]
MSGTO
FF
MSGPE
MSGR
MSGRL[2:0]
Msg FIFO 1
Msg FIFO 2
Msg FIFO 3
Msg FIFO 4
Msg FIFO 5
Msg FIFO 6
LNB S Ctrl1
LNB S Ctrl2
LNB S Ctrl3
LNB S Ctrl4
LNB S Stat
FIFO1[7:0]
FIFO2[7:0]
FIFO3[7:0]
FIFO4[7:0]
FIFO5[7:0]
FIFO6[7:0]
RT
RT
RT
RT
RT
RT
I
VLOW[3:0]
VHIGH[3:0]
ILIM[1:0]
IMAX[1:0]
SLOT[1:0]
OLOT[1:0]
I
VMON[7:0]
LNB_EN
S
LNBL
COMP
LNBMD
OCD
I
SCD
S
Preliminary Rev. 0.81
37
Si2107/08/09/10
Table 19. Register Summary (Continued)
I2C
Name
D7
D6
D5
D4
D3
D2
D1
D0
Addr.
QuickScan
Host Ctrl
1Ch
SR_
ADCSR_
CTF_CTRL_ FTF_CTRL_
I
CTRL_ CTRL_HOST
HOST
HOST
HOST
RS Est L
RS Est M
31h
32h
33h
3Ah
SREST[7:0]
RT
RT
RT
I
SREST[15:8]
SREST[23:16]
RS Est H
SR Est Ctrl 2
FALSE_ALA
RM_PROC_
EN
SR Max
SR Min
BS Ctrl
42h
43h
80h
SRMAX[7:0]
SRMIN[7:0]
I
I
BS_
BSDA
COESM
RT
START
BS MinFreq L
BS MinFreq M
BS MinFreq H
BS MaxFreq L
BS MaxFreq M
BS MaxFreq H
BS CoarseFreq
BS FineFreq L
BS FineFreq H
BS PLL Div
81h
82h
83h
84h
85h
86h
89h
8Ah
8Bh
8Ch
8Dh
8Eh
BS_FMIN[7:0]
BS_FMIN[15:8]
I
I
BS_FMIN[17:16}
I
BS_FMAX[7:0]
BS_FMAX[15:8]
I
I
BS_FMAX[17:16}
I
BS_CTF[7:0]
BS_FTF[7:0]
RT
RT
RT
RT
I
BS_FTF[14:8]
BS_ADCSR[7:0]
LSA Ctrl 1
AVG WIN[6:5]
Spectrum Tilt
Correction
Threshold
SPEC_TILT_CORREC[7:0]
I
1dB BW
Threshold
90h
91h
92h
93h
94h
BW_1dB[7:0]
BW_2dB[7:0]
I
I
I
I
I
2dB BW
Threshold
3dB BW
Threshold
BW_3dB[7:0]
Inband Power
Threshold
INBAND_THRESHOLD[7:0]
REF_NOISE_MARGIN[7:0]
Noise Level
Margin Threshold
38
Preliminary Rev. 0.81
Si2107/08/09/10
Register 00h. Device ID Register
Bit
D7
D6
D5
D4
D3
D2
REV[3:0]
D1
D0
Name
DEV[3:0]
Bit
Name
Function
7:4
DEV[3:0]
REV[3:0]
Device ID.
0h = Si2110
1h = Si2109
2h = Si2108
3h = Si2107
3:0
Revision.
Current revision = 4h
Register 01h. System Mode
Bit
D7
D6
D5
INC_DS
D4
D3
D2
D1
D0
Name
0
0
MOD[1:0]
SYSM[2:0]
Bit
7:6
5
Name
Function
Reserved
INC_DS
Program as shown above.
2
I C Automatic Address Increment Disable.
0 = Enabled (default)
1 = Disabled
4:3
2:0
MOD[1:0]
Modulation Selection.
00 = BPSK Demodulation
01 = QPSK Demodulation (default)
10 = Reserved
11 = Reserved
SYSM[2:0]
System Mode.
000 = DVB-S (default)
001 = DSS
010–111 = Reserved
Preliminary Rev. 0.81
39
Si2107/08/09/10
Register 02h. Transport Stream Control 1
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
TSEP
TSVP
TSSP
TSSL
TSCM
TSCE
TSDF
TSM
Bit
Name
Function
7
TSEP
TSVP
TSSP
TSSL
Transport Stream Error Polarity.
0 = Active high (default)
1 = Active low
6
5
4
Transport Stream Valid Polarity.
0 = Active high (default)
1 = Active low
Transport Stream Sync Polarity.
0 = Active high (default)
1 = Active low
Transport Stream Start Length.
0 = Byte wide (default)
1 = Bit wide
Note: This bit is ignored in parallel mode.
3
2
1
TSCM
TSCE
TSDF
Transport Stream Clock Mode.
0 = Gapped mode (default)
1 = Continuous mode
Transport Stream Clock Edge.
0 = Data transitions on rising edge (default)
1 = Data transitions on falling edge
Transport Stream Serial Data Format.
0 = MSB first (default)
1 = LSB first
Note: This bit is ignored in parallel mode
0
TSM
Transport Stream Mode.
0 = Serial (default)
1 = Parallel
40
Preliminary Rev. 0.81
Si2107/08/09/10
Register 03h. Transport Stream Control 2
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
TSPCS
TSCD
TSDD
TSPG
TSSCR[1:0]
Bit
7:6
5
Name
Function
Reserved
TSPCS
Program as shown above.
Transport Stream Parallel Clock Smoother.
Smoothens TS_CLK to ~50% duty cycle.
0 = Smoothing disabled
1 = Smoothen clock to ~50% duty cycle (default)
4
3
TSCD
TSDD
Transport Stream Clock Delay.
Adds delay to TS_CLK to adjust clock-data timing relationship.
0 = Normal operation (default)
1 = Delay clock relative to data
Transport Stream Data Delay.
Adds delay to TS_DATA, TS_SYNC, TS_VAL, TS_ERR output to adjust
clock-data timing relationship.
0 = Normal operation (default)
1 = Delay data relative to clock
2
TSPG
Transport Stream Parity Gate.
0 = Normal operation (default)
1 = Zero data lines during parity
1:0
TSSCR[1:0]
Transport Stream Serial Clock Rate.
00 = 80–88.5 MHz (default)
01 = 76.8–82.8 MHz
10 = 54.8–59.2 MHz
11 = 34.9–37.7 MHz
The user should select a setting such that the corresponding minimum
clock output frequency is higher than the expected output bit rate.
Preliminary Rev. 0.81
41
Si2107/08/09/10
Register 04h. Pin Control 1
D7
D6
D5
D4
D3
D2
D1
D0
Bit
INT_EN
INTT
INTP
TSE_OE
TSV_OE
TSS_OE
TSC_OE
TSD_OE
Name
Bit
Name
Function
7
INT_EN
Interrupt Pin Enable.
0 = Disabled (default)
1 = Enabled
6
5
4
3
2
1
0
INTT
Interrupt Pin Type.
0 = CMOS (default)
1 = Open drain/source
INTP
Interrupt Polarity.
0 = Active low (default)
1 = Active high
TSE_OE
TSV_OE
TSS_OE
TSC_OE
TSD_OE
Transport Stream Error Output Enable.
0 = Enabled
1 = Tri-state (default)
Transport Stream Valid Output Enable.
0 = Enabled
1 = Tri-state (default)
Transport Stream Sync Output Enable.
0 = Enabled
1 = Tri-state (default)
Transport Stream Clock Output Enable.
0 = Enabled
1 = Tri-state (default)
Transport Stream Data Output Enable.
0 = Enabled
1 = Tri-state (default)
42
Preliminary Rev. 0.81
Si2107/08/09/10
Register 05h. Pin Control 2
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
0
1
0
0
GPO
PSEL[1:0]
Bit
7:3
2
Name
Function
Reserved
GPO
Program as shown above.
General Purpose Output Control.
Controls output of pin 30 when PSEL = 10
0 = Output logic zero. (default)
1 = Output logic 1.
1:0
PSEL[1:0]
Pin Select (Pin 30).
00 = Interrupt (default)
01 = Receiver lock indicator
10 = General Purpose Output
11 = Reserved
Register 06h. Bypass
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
0
DS_BP
RS_BP
DI_BP
0
0
0
Bit
7:6
5
Name
Reserved
DS_BP
Function
Program as shown above.
Descrambler Bypass.
0 = Normal operation (default)
1 = Bypass
Note: This bit is ignored in DSS mode; the descrambler is automatically
bypassed.
4
3
RS_BP
DI_BP
Reed-Solomon Bypass.
0 = Normal operation (default)
1 = Bypass
Deinterleaver Bypass.
0 = Normal operation (default)
1 = Bypass
2:0
Reserved
Program as shown above.
Preliminary Rev. 0.81
43
Si2107/08/09/10
Register 07h. Interrupt Enable 1
Bit
D7
D6
D5
D4
D3
D2
D1
D1
Name
RCVL_E
AGCL_E
CEL_E
0
STL_E
CRL_E
VTL_E
FSL_E
Bit
Name
Function
7
RCVL_E
AGCL_E
CEL_E
Receiver Lock Interrupt Enable.
0 = Disabled (default)
1 = Enabled
6
5
AGC Lock Interrupt Enable.
0 = Disabled (default)
1 = Enabled
Carrier Estimator Lock Interrupt Enable.
0 = Disabled (default)
1 = Enabled
4
3
Reserved
STL_E
Program as shown above.
Symbol Timing Lock Interrupt Enable.
0 = Disabled (default)
1 = Enabled
2
1
0
CRL_E
VTL_E
FSL_E
Carrier Recovery Lock Interrupt Enable.
0 = Disabled (default)
1 = Enabled
Viterbi Search Lock Interrupt Enable.
0 = Disabled (default)
1 = Enabled
Frame Sync Lock Interrupt Enable.
0 = Disabled (default)
1 = Enabled
44
Preliminary Rev. 0.81
Si2107/08/09/10
Register 08h. Interrupt Enable 2
Bit
D7
D6
D5
D4
D3
D2
D1
D1
Name
RCVU_E
AGCTS_E
STU_E
CRU_E
VTU_E
FSU_E
0
AQF_E
Bit
Name
Function
7
RCVU_E
AGCTS_E
STU_E
Receiver Unlock Interrupt Enable.
0 = Disabled (default)
1 = Enabled
6
5
4
3
2
AGC Tracking Threshold Interrupt Enable.
0 = Disabled (default)
1 = Enabled
Symbol Timing Unlock Interrupt Enable.
0 = Disabled (default)
1 = Enabled
CRU_E
VTU_E
Carrier Recovery Unlock Interrupt Enable.
0 = Disabled (default)
1 = Enabled
Viterbi Search Unlock Interrupt Enable.
0 = Disabled (default)
1 = Enabled
FSU_E
Frame Sync Unlock Interrupt Enable.
0 = Disabled (default)
1 = Enabled
1
0
Reserved
AQF_E
Program as shown above.
Acquisition Fail Interrupt Enable.
0 = Disabled (default)
1 = Enabled
Preliminary Rev. 0.81
45
Si2107/08/09/10
Register 09h. Interrupt Enable 3
Bit
D7
D6
D5
D4
D3
D2
D1
D1
Name
CN_E
VTER_E
RSER_E
MSGPE_E
FE_E
FF_E
MSGR_E
MSGTO_E
Bit
Name
Function
7
CN_E
C/N Estimator Interrupt Enable.
0 = Disabled (default)
1 = Enabled
6
5
4
3
2
1
0
VTER_E
RSER_E
MSGPE_E
FE_E
Viterbi BER Interrupt Enable.
0 = Disabled (default)
1 = Enabled
Reed-Solomon Error Measurement Interrupt Enable.
0 = Disabled (default)
1 = Enabled
LNB Message Parity Error Interrupt Enable.
0 = Disabled (default)
1 = Enabled
LNB Transmit FIFO Empty Interrupt Enable.
0 = Disabled (default)
1 = Enabled
FF_E
LNB Receive FIFO Full Interrupt Enable.
0 = Disabled (default)
1 = Enabled
MSGR_E
MSGTO_E
LNB Receive Message Interrupt Enable.
0 = Disabled (default)
1 = Enabled
LNB Receive Timeout Interrupt Enable.
0 = Disabled (default)
1 = Enabled
46
Preliminary Rev. 0.81
Si2107/08/09/10
Register 0Ah. Interrupt Enable 4
Bit
D7
0
D6
0
D5
0
D4
Si2107/8
D3
0
D2
0
D1
D0
Part
Name
Part
0
SCD_E
SCD_E
OCD_E
OCD_E
Si2109/10
Name
0
BSDO_E
BSDA_E0
0
0
0
Bit
7
Name
Function
Reserved
BSDO_E
Program as shown above.
6
Blindscan Done Interrupt Enable.
0 = Disabled (default)
1 = Enabled
5
BSDA_E
Blindscan Data Ready Interrupt Enable.
0 = Disabled (default)
1 = Enabled
4:2
1
Reserved
SCD_E
Program as shown above.
Short Circuit Detect Interrupt Enable.
0 = Disabled (default)
1 = Enabled
0
OCD_E
Over Current Detect Interrupt Enable.
0 = Disabled (default)
1 = Enabled
Preliminary Rev. 0.81
47
Si2107/08/09/10
Register 0Bh. Interrupt Status 1
Bit
D7
D6
D5
D4
D3
D2
D1
D1
Name
RCVL_I
AGCL_I
CEL_I
0
STL_I
CRL_I
VTL_I
FSL_I
Bit
Name
Function
7
RCVL_I
AGCL_I
CEL_I
Receiver Lock Interrupt.
0 = Disabled (default)
1 = Enabled
6
5
AGC Lock Interrupt.
0 = Disabled (default)
1 = Enabled
Carrier Estimator Lock Interrupt.
0 = Disabled (default)
1 = Enabled
4
3
Reserved
STL_I
Program as shown above.
Symbol Timing Lock Interrupt.
0 = Disabled (default)
1 = Enabled
2
1
0
CRL_I
VTL_I
FSL_I
Carrier Recovery Lock Interrupt.
0 = Disabled (default)
1 = Enabled
Viterbi Search Lock Interrupt.
0 = Disabled (default)
1 = Enabled
Frame Sync Lock Interrupt.
0 = Disabled (default)
1 = Enabled
48
Preliminary Rev. 0.81
Si2107/08/09/10
Register 0Ch. Interrupt Status 2
Bit
D7
D6
D5
D4
D3
D2
D1
D1
RCVU_I
AGCTS_I
STU_I
CRU_I
VTU_I
FSU_I
0
AQF_I
Name
Bit
7
Name
RCVU_I
AGCTS_I
Function
Receiver Unlock Interrupt.
6
AGC Tracking Threshold Interrupt.
0 = Normal operation (default)
1 = Event recorded
5
4
3
2
STU_I
CRU_I
VTU_I
FSU_I
Symbol Timing Unlock Interrupt.
0 = Normal operation (default)
1 = Event recorded
Carrier Recovery Unlock Interrupt.
0 = Normal operation (default)
1 = Event recorded
Viterbi Search Unlock Interrupt.
0 = Normal operation (default)
1 = Event recorded
Frame Sync Unlock Interrupt.
0 = Normal operation (default)
1 = Event recorded
1
0
Reserved
AQF_I
Program as shown above.
Acquisition Fail Interrupt.
0 = Normal operation (default)
1 = Event recorded
Preliminary Rev. 0.81
49
Si2107/08/09/10
Register 0Dh. Interrupt Status 3
Bit
D7
D6
D5
D4
D3
D2
D1
D1
Name
CN_I
VTER_I
RSER_I MSGPE_I
FE_I
FF_I
MSGR_I
MSGTO_I
Bit
Name
Function
7
CN_I
C/N Estimator Interrupt.
0 = Normal operation (default)
1 = Event recorded
6
5
4
3
2
1
0
VTER_I
RSER_I
MSGPE_I
FE_I
Viterbi BER Interrupt.
0 = Normal operation (default)
1 = Event recorded
Reed-Solomon Error Measurement Complete Interrupt.
0 = Normal operation (default)
1 = Event recorded
LNB Message Parity Error Interrupt.
0 = Normal operation (default)
1 = Event recorded
LNB Transmit FIFO Empty Interrupt.
0 = Normal operation (default)
1 = Event recorded
FF_I
LNB Receive FIFO Full Interrupt.
0 = Normal operation (default)
1 = Event recorded
MSGR_I
MSGTO_I
LNB Receive Message Interrupt.
0 = Normal operation (default)
1 = Event recorded
LNB Receive Timeout Interrupt.
0 = Normal operation (default)
1 = Event recorded
50
Preliminary Rev. 0.81
Si2107/08/09/10
Register 0Eh. Interrupt Status 4
Bit
D7
0
D6
0
D5
0
D4
Si2107/8
D3
0
D2
0
D1
D0
Part
Name
Part
0
SCD_I
SCD_I
OCD_I
OCD_I
Si2109/10
Name
0
BSDO_I
BSDA_I
0
0
0
Bit
7
Name
Function
Reserved
BSDO_I
Program to zero.
6
Blindscan Done Interrupt.
0 = Normal operation (default)
1 = Blindscan done over the specified frequency range
5
BSDA_I
Blindscan Data Ready Interrupt.
0 = Normal operation (default)
1 = Blindscan data can be read from registers:
BS_CTF, BS_FTF, CFER, SREST, BS_ADCSR.
4:2
1
Reserved
SCD_I
Program as shown above.
Short Circuit Detect Interrupt.
0 = Normal operation (default)
1 = Event recorded
0
OCD_I
Over Current Detect Interrupt.
0 = Normal operation (default)
1 = Event recorded
Preliminary Rev. 0.81
51
Si2107/08/09/10
Register 0Fh. Lock Status 1
Bit
D7
D6
D5
D4
D3
D2
D1
D0
0
AGCL
CEL
SRL
STL
CRL
VTL
FSL
Name
Bit
7
Name
Reserved
AGCL
Function
Program as shown above.
6
AGC Lock Status.
0 = Pending (default)
1 = Complete
5
4
CEL
SRL
Carrier Estimation Status.
0 = Pending (default)
1 = Complete
Symbol Rate Estimation Status.
0 = Pending (default)
1 = Complete
Note: Available on Si2109/10 only.
3
2
1
0
STL
CRL
VTL
FSL
Symbol Timing Lock Status.
0 = Unlocked (default)
1 = Locked
Carrier Lock Status.
0 = Unlocked (default)
1 = Locked
Viterbi Lock Status.
0 = Unlocked (default)
1 = Locked
Frame Sync Lock Status.
0 = Unlocked (default)
1 = Locked
52
Preliminary Rev. 0.81
Si2107/08/09/10
Register 10h. Lock Status 2
Bit
D7
D6
0
D5
0
D4
Si2107/8
D3
0
D2
0
D1
0
D0
0
Part
Name
Part
RCVL
RCVL
0
Si2109/10
Name
0
0
0
0
0
BSDA
BSDO
Bit
Name
Function
7
RCVL
Receiver Lock Status.
0 = Unlocked (default)
1 = Locked
6:2
1
Reserved
BSDA
Program as shown above.
Blindscan Data Ready (LSA stage)
0 = Normal operation (default)
1 = Raw carrier and symbol rate ready for readout by host.
0
BSDO
Blindscan Done.
0 = Normal operation (default)
1 = Blindscan sequence complete over the specified frequency range.
Preliminary Rev. 0.81
53
Si2107/08/09/10
Register 11h. Acquisition Status
Bit
D7
D6
D5
D4
D3
D2
D1
D1
Name
AQF
AGCF
CEF
SRF
STF
CRF
VTF
FSF
Bit
Name
Function
7
AQF
Receiver Acquisition Status.
0 = Normal operation (default)
1 = Acquisition failed
6
5
4
AGCF
CEF
AGC Search Status.
0 = Normal operation (default)
1 = Gain control limit reached
Carrier Estimation Search Status.
0 = Normal operation (default)
1 = Carrier offset not found
SRF
Symbol Rate Search Status.
0 = Normal operation (default)
1 = Search failed
Note: Available on Si2109/10 only.
3
2
1
0
STF
CRF
VTF
FSF
Symbol Timing Search Status.
0 = Normal operation (default)
1 = Search failed
Carrier Search Status.
0 = Normal operation (default)
1 = Search failed
Viterbi Search Status.
0 = Normal operation (default)
1 = Search failed
Frame Sync Search Status.
0 = Normal operation (default)
1 = Search failed
54
Preliminary Rev. 0.81
Si2107/08/09/10
Register 14h. Acquisition Control 1
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
AQS
0
0
0
0
0
0
0
Bit
Name
Function
Automatic Acquisition Start.
7
AQS
Writing a one to this bit initiates the acquisition sequence. This bit is
automatically cleared when the acquisition sequence completes.
6:0
Reserved
Program as shown above.
Register 15h. ADC Sampling Rate
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
ADCSR[7:0]
Bit
Name
ADCSR[7:0]
Function
7:0
ADC Sampling Rate.
f = ADCSR x 1 MHz
s
Default: C8h (200 MHz)
Register 16h. Coarse Tune Frequency
Bit
D7
D6
D5
D4
CTF[7:0]
D3
D2
D1
D0
Name
Bit
Name
CTF[7:0]
Function
7:0
Coarse Tune Frequency.
Calculation of the coarse tune value is determined by the reference
software driver.
f
= CTF x 10 MHz
coarse
Default: 00h
Preliminary Rev. 0.81
55
Si2107/08/09/10
Register 17h. Fine Tune Frequency L
Bit
D7
D6
D5
D4
FTF[7:0]
D3
D2
D1
D0
Name
Bit
Name
FTF[7:0]
Function
Fine Tune Frequency (Low Byte).
7:0
fs
214
--------
ffine = FTF ×
where FTF is stored as a 2s complement value.
Calculation of the fine tune value is determined by the reference soft-
ware driver.
Default: 00h
Register 18h. Fine Tune Frequency H
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
FTF[14:8]
Bit
7
Name
Function
Reserved
FTF[14:8]
Program as shown above.
6:0
Fine Tune Frequency (High Byte).
See Register 17h.
56
Preliminary Rev. 0.81
Si2107/08/09/10
Register 1Ch. Host Control Register (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
0
0
0
SR_ CTRL_
HOST
ADCSR_CTRL_ CTF_CTRL_ FTF_CTRL_
HOST
HOST
HOST
Bit
7:4
3
Name
Function
Reserved
Program as shown above.
SR_CTRL_HOST
Symbol Rate Host Control
0 = control by chip (during BSC)
1 = control from host (during normal operation) (default)
2
1
0
ADCSR_CTRL_HOST
CTF_CTRL_HOST
FTF_CTRL_HOST
ADC Sampling Rate Host Control.
0 = Control by chip (during BSC)
1 = Control by host (during normal operation) (default)
Coarse Tune Frequency Host Control.
0 = Control by chip (during BSC)
1 = Control by host (during normal operation) (default)
Fine Tune Frequency Host Control.
0 = Control by chip (during BSC)
1 = Control by host (during normal operation) (default)
Register 23h. Analog AGC Control 1
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
0
AGCW[1:0]
0
0
0
0
Bit
7:6
5:4
Name
Function
Reserved
AGCW[1:0]
Program as shown above.
AGC Measurement Window.
Acquisition
00 = 1024 (default)
01 = 2048
Tracking
65536 samples (default)
131072 samples
10 = 4096
262144 samples
11 = 8192
524288 samples
3:0
Reserved
Program as shown above.
Preliminary Rev. 0.81
57
Si2107/08/09/10
Register 24h. AGC Control 2
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
AGCTR[3:0]
AGCO[3:0]
Bit
Name
Function
7:4
AGCTR[3:0]
AGC Tracking Threshold.
Specifies the maximum difference between AGCPWR (28h) and
AGCTH (27h) before making a gain adjustment.
Default: 1000.
3:0
AGCO[3:0]
AGC Gain Offset.
Minimum value for gain stage 4.
0000 = +0 dB (default)
0001 = +1 dB
…
1110 = +14 dB
1111 = +15 dB
Register 25h. Analog AGC 1–2 Gain
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
AGC2[3:0]
AGC1[3:0]
Bit
Name
Function
7:4
AGC2[3:0]
Analog Gain stage 2 setting.
Default: 0h
3:0
AGC1[3:0]
Analog Gain stage 1 setting.
Default: 0h
Register 26h. Analog AGC 3–4 Gain
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
AGC4[3:0]
AGC3[3:0]
Bit
Name
Function
7:4
AGC4[3:0]
Analog Gain stage 4 setting
Default: 0h
3:0
AGC3[3:0]
Analog Gain stage 3 setting
Default: 0h
58
Preliminary Rev. 0.81
Si2107/08/09/10
Register 27h. AGC Threshold
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
AGCTH[6:0]
Bit
7
Name
Function
Reserved
Program as shown above.
6:0
AGCTH[6:0]
Analog AGC Threshold.
The value specified in this register corresponds to the desired analog
AGC power level. The AGC loop adjusts the gain of the system to drive
the AGC power level to this value.
Default: 20h.
Register 28h. AGC Power Level
D7
D6
D5
D4
D3
D2
D1
D0
Bit
0
AGCPWR[6:0]
Name
Bit
7
Name
Function
Reserved
Program as shown above.
6:0
AGCPWR[6:0]
AGC Power Level.
Represents the measured input power level after the ADC in rms format.
The measurement window is set by AGCW. This register saturates at full
scale.
Default: 00h.
Preliminary Rev. 0.81
59
Si2107/08/09/10
Register 29h. Carrier Estimation Control
D7
D6
D5
D4
D3
D2
D1
D0
Bit
0
0
0
0
1
CESR[2:0]
Name
Bit
7:3
2:0
Name
Function
Reserved
Program as shown above.
CESR[2:0]
Carrier Estimation Search Range.
000 = ± f /16
(± 12.0 MHz typ.) Exclusive to QuickLock.
(± 6.3 MHz typ.) (default)
(± 3.1 MHz typ.)
s
001 = ± f /32
s
010 = ± f /64
s
011 = ± f /128
(± 1.6 MHz typ.)
s
100 = ± f /256
(± 0.8 MHz typ.)
s
101 = ± f /512
(± 0.4 MHz typ.)
s
110 = ± f /1024
(± 0.2 MHz typ.)
s
111 = ± f /2048
(± 0.1 MHz typ.)
s
Register 31h. Symbol Rate Estimator Register L (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
SREST[7:0]
Bit
Name
SREST[7:0]
Function
Symbol Rate Estimate (Low Byte).
7:0
Result of blindscan symbol rate estimator.
Symbol rate = SREST x sampling_rate / 2^23.
sampling_rate is the ADC sampling rate as calculated from BS_ADCSR.
Default: 00h
Register 32h. Symbol Rate Estimator Register M (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
SREST[15:8]
Bit
Name
SREST[15:8]
Function
7:0
Symbol Rate Estimate (Mid Byte).
See register 31h.
Default: 00h
60
Preliminary Rev. 0.81
Si2107/08/09/10
Register 33h. Symbol Rate Estimator Register H (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
SREST[23:16]
Bit
Name
SREST[23:16]
Function
7:0
Symbol Rate Estimate (High Byte).
See register 31h.
Default: 00h
Register 36h. Carrier Estimator Offset L
D7
D6
D5
D4
CFO[7:0]
D3
D2
D1
D0
Bit
Name
Bit
Name
CFO[7:0]
Function
Carrier Frequency Offset (Low Byte).
7:0
Designed to store a residual carrier frequency offset for future acquisi-
tions. Used during carrier offset estimation to adjust the center fre-
quency.
fs
215
--------
Search center frequency = fdesired + CFO ×
Hz
Note: CFO is a 16-bit two’s complement number.
Default: 00h
Preliminary Rev. 0.81
61
Si2107/08/09/10
Register 37h. Carrier Estimator Offset H
D7
D6
D5
D4
CFO[15:8]
D3
D2
D1
D0
Bit
Name
Bit
Name
CFO[15:8]
Function
7:0
Carrier Frequency Offset (High Byte).
See register 36h.
Register 38h. Carrier Frequency Offset Error L
D7
D6
D5
D4
CFER[7:0]
D3
D2
D1
D0
Bit
Name
Bit
Name
CFER[7:0]
Function
Carrier Frequency Offset Error (Low Byte).
7:0
Stores the carrier frequency offset that is identified during the carrier
offset estimation stage.
fs
--------
Offset = –CFER ×
Hz
215
Note: CFER is a 16-bit two’s complement number.
Default: 00h
Register 39h. Carrier Frequency Offset Error H
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
CFER[15:8]
Bit
Name
CFER[15:8]
Function
7:0
Carrier Frequency Offset Error (High Byte).
See register 38h.
62
Preliminary Rev. 0.81
Si2107/08/09/10
Register 3Ah. Symbol Rate Estimator Control 2 Register
D7
D6
D5
D4
D3
D2
D1
D0
Bit
0
0
0
0
0
0
0
FALSE_ALARM_PROC_EN
Name
Bit
7:1
0
Name
Function
Reserved
Program as shown above.
FALSE_ALARM_PROC_EN
Enable the SRE to check for false symbol rate alarms
Default: 01h
Register 3Fh. Symbol Rate L
Bit
D7
D6
D5
D4
SR[7:0]
D3
D2
D1
D0
Name
Bit
Name
SR[7:0]
Function
7:0
Symbol Rate (Low Byte).
Symbol rate = SR ×
fs
224
--------
Hz
Sampling_rate is the ADC sampling rate as calculated from
BS_ADCSR.
Default: 00h.
Register 40h. Symbol Rate M
D7
D6
D5
D4
SR[15:8]
D3
D2
D1
D0
Bit
Name
Bit
Name
SR[15:8]
Function
7:0
Symbol Rate (Mid Byte).
See register 3Fh.
Preliminary Rev. 0.81
63
Si2107/08/09/10
Register 41h. Symbol Rate H
Bit
D7
D6
D5
D4
SR[23:16]
D3
D2
D1
D0
Name
Bit
Name
SR[23:16]
Function
7:0
Symbol Rate (High Byte).
See register 3F.
Register 42h. Symbol Rate Maximum (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
SRMAX[7:0]
Bit
Name
SRMAX[7:0]
Function
Symbol Rate Estimation Maximum.
Max symbol rate = SRMX ×
7:0
fs
216
--------
Hz
Sampling_rate is the ADC sampling rate as calculated from
BS_ADCSR.
Default: 00h.
Register 43h. Symbol Rate Minimum (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
SRMIN[7:0]
Bit
Name
SRMIN[7:0]
Function
Symbol Rate Estimation Minimum.
7:0
fs
216
--------
Min symbol rate = SRMN ×
Hz
Sampling_rate is the ADC sampling rate as calculated from
BS_ADCSR.
Default: 00h.
64
Preliminary Rev. 0.81
Si2107/08/09/10
Register 75h. Digital AGC 1 Control
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
DAGC1_EN
DAGC1W[1:0]
DAGC1T DAGC1HOLD
DAGC1HOST
0
Bit
Name
Function
7
Reserved
Program as shown above (device may change the value of this bit
during operation)
6
DAGC1_EN
Enable digital AGC 1
0 = Disabled
1 = Enabled (default)
5:4
DAGC1W[1:0]
Digital AGC Measurement Window
00 = 256 samples
01 = 512 samples
10 = 1024 samples (default)
11 = 2048 samples
3
2
1
DAGC1T
Select AGC threshold
0 = –15 dBFS (default)
1 = –9 dBFS
DAGC1HOLD
DAGC1HOST
Hold previous computed gain value on DAGC1
0 = Update gain after each calculation (default)
1 = Do not update gain value
Host-controlled DAGC1
Enable host control of holding of gain.
0 = control internal to chip (default)
1 = host control via registers DAGC1HOLD and DAGC1T
0
Reserved
Program as shown above.
Register 76h. Digital AGC 1 Gain L
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
DAGC1[7:0]
Bit
Name
DAGC1[7:0]
Function
7:0
Gain of digital AGC 1 (low-byte).
Default: 00h
Preliminary Rev. 0.81
65
Si2107/08/09/10
Register 77h. Digital AGC 1 Gain H
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
DAGC1[15:8]
Bit
Name
DAGC1[15:8]
Function
7:0
Gain of digital AGC 1 (high-byte).
Default: 00h
Register 78h. Digital AGC 2 Control
Bit
D7
D6
D5
D4
D3
D2
D1
D0
DAGC2TDIS
Name
Reserved
DAGC2[3:0]
DAGC2W[1:0]
Bit
Name
Reserved
Function
7
Program as shown above. (device may change the value of this bit
during operation)
6:3
2:1
DAGC2[3:0]
Digital AGC2 gain factor
Default: 0h
DAGC2W[1:0]
Digital AGC2 Measurement window
Acquisition
Tracking
00 = 16 samples (default)
01 = 32 samples
10 = 64 samples
11 = 128 samples
1024 samples (default)
2048 samples
4096 samples
8192 samples
0
DAGC2TDIS
Digital AGC2 Automatic Tracking Disable
1 = Disable automatic tracking. Freeze applied to gain.
0 = Enable automatic tracking. (default)
Register 79h. Digital AGC 2 Threshold
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
DAGC2T[7:0]
Bit
Name
DAGC2T[7:0]
Function
7:0
Digital AGC2 Threshold.
Default: B5h
66
Preliminary Rev. 0.81
Si2107/08/09/10
Register 7Ah. Digital AGC 2 Level L
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
DAGC2GA[7:0]
Bit
Name
DAGC2GA[7:0]
Function
7:0
Digital AGC2 Gain Auto (low byte).
Digital AGC2 gain applied to meet threshold
Default: 00h
Register 7Bh. Digital AGC 2 Level H
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
DAGC2GA[15:8]
Bit
Name
DAGC2GA[15:8]
Function
7:0
Digital AGC2 Gain Auto (high byte).
See register 7Ah.
Default: 00h
Register 7Ch. C/N Estimator Control
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
CNS
0
0
0
CNM
CNW[1:0]
0
Bit
Name
Function
7
CNS
C/N Estimator Start.
Writing a one to this bit initiates an C/N estimator and clears the result
stored in CNL. This bit is automatically cleared to zero when the mea-
surement period elapses.
6:3
2
Reserved
CNM
Program as shown above.
C/N Estimator Mode.
0 = Finite window
1 = Infinite window (default)
1:0
CNW[1:0]
C/N Measurement Window.
00 = 1024 samples
01 = 4096 samples (default)
10 = 16384 samples
11 = 65536 samples
Preliminary Rev. 0.81
67
Si2107/08/09/10
Register 7Dh. C/N Estimator Threshold0
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
CNET[7:0]
Bit
Name
CNET[7:0]
Function
7:0
C/N Estimator Threshold.
This value defines a noise threshold for the C/N estimator.
Default 13h.
Register 7Eh. C/N Estimator Level L
Bit
D7
D6
D5
D4
CNL[7:0]
D3
D2
D1
D0
Name
Bit
Name
CNL[7:0]
Function
C/N Estimator Level (Low Byte).
7:0
The value in this register is to be used with an external lookup table to
estimate the C/N of the input signal.
Default: 00h.
Register 7Fh. C/N Estimator Level H
Bit
D7
D6
D5
D4
CNL[15:8]
D3
D2
D1
D0
Name
Bit
Name
CNL[15:8]
Function
7:0
C/N Estimator Level (High Byte).
See Register 7Eh.
68
Preliminary Rev. 0.81
Si2107/08/09/10
Register 80h. Blindscan Control Register
Bit
D7
D6
D5
D4
D3
D2
D1
D0
BS_START
Name
0
BSDA
0
0
0
0
COESM
Bit
Name
Function
7
BS_START
Blindscan Start.
0 = normal operation (default)
1 = start blindscan.
6
5
Reserved
BSDA
Program as shown above.
Blindscan Data Ready.
0 = Cleared by host. Indicates host has read the valid channel
information from the register bank and the device can write new
values for the next channel.
1 = Set by the device. Remains set as long as the host has not read
the channel information from the register bank. The blindscan
operation waits for the host to clear the bit before writing values for the
next channel.
4:1
0
Reserved
COESM
Program as shown above.
Carrier Offset Estimation Selection Mode.
0 = Legacy Mode (default)
1 = QuickLock
Register 81h. Blindscan Controller Minimum Frequency Register L (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
BS_FMIN[7:0]
Bit
Name
BS_FMIN[7:0]
Function
7:0
Lower RF frequency limit for QuickScan range:
14
Minimum Frequency (MHz)
-----------------------------------------------------------------------
BS_FMIN =
× 2
BS_ADCSR (MHz)
Default: 14h
Preliminary Rev. 0.81
69
Si2107/08/09/10
Register 82h. Blindscan Controller Minimum Frequency Register M (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
BS_FMIN[15:8]
Function
D3
D2
D1
D0
Name
Bit
Name
BS_FMIN[15:8]
7:0
See register 81h.
Default: 08h
Register 83h. Blindscan Controller Minimum Frequency Register H (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
0
0
0
0
0
BS_FMIN[17:16]
Bit
7:2
1:0
Name
Function
Reserved
Program as shown above.
See register 81h.
Default: 01h
BS_FMIN[17:16]
Register 84h. Blindscan Controller Maximum Frequency Register L (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
BS_FMAX[7:0]
Bit
Name
BS_FMAX[7:0]
Function
7:0
Higher RF frequency limit for QuickScan range:
14
Maximum Frequency (MHz)
-------------------------------------------------------------------------
BS_FMAX =
× 2
BS_ADCSR (MHz)
Default: F6h
70
Preliminary Rev. 0.81
Si2107/08/09/10
Register 85h. Blindscan Controller Maximum Frequency Register M (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
BS_FMAX[15:8]
Function
D3
D2
D1
D0
Name
Bit
Name
BS_FMAX[15:8]
7:0
See register 84h.
Default: 9Bh
Register 86h. Blindscan Controller Maximum Frequency Register H (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
0
0
0
0
0
BS_FMAX[17:16]
Bit
7:2
1:0
Name
Reserved
BS_FMAX[17:16]
Function
Program as shown above.
See register 84h.
Default: 02h
Register 89h. Blindscan Controller Coarse Tuning Frequency Register (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
BS_CTF[7:0]
Bit
Name
BS_CTF[7:0]
Function
7:0
Coarse frequency of identified channel = 10 MHz x BS_CTF.
Default: 00h
Register 8Ah. Blindscan Controller Fine Tuning Frequency Register L (Si2109 and Si2110 only)
D7
D6
D5
D4
D3
D2
D1
D0
Bit
BS_FTF[7:0]
Name
Bit
Name
BS_FTF[7:0]
Function
7:0
Fine frequency of identified channel, low byte.
Fine frequency = BS_Fs/16384 x BS_FTF
Default: 00h
Preliminary Rev. 0.81
71
Si2107/08/09/10
Register 8Bh. Blindscan Controller Fine Tuning Frequency Register H (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
BS_FTF[14:8]
Bit
7
Name
Function
Reserved
Program as shown above.
6:0
BS_FTF[14:8]
Fine frequency of identified channel, high byte.
See register 8Ah.
Default: 00h
Register 8Ch. Blindscan Controller ADC Sampling Rate Register (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
BS_ADCSR[7:0]
Function
D3
D2
D1
D0
Name
Bit
Name
BS_ADCSR[7:0]
7:0
Blindscan ADC Sampling Rate used for the identified channel.
BS_Fs = BS_ADCSR x 1 MHz
Default: 00h
Register 8Dh. LSA Control 1 Register (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
AVG_WIN[6:5]
02h
01h
02h
Bit
7
Name
Function
Reserved
Program as shown above.
6:5
AVG_WIN[6:5]
Length of the time averaging window for computation for LSA in blind scan mode.
Refer to Silicon Laboratories application note AN298 for recommended default val-
ues for QuickLock/QuickScan operation.
4:3
2
Reserved
Reserved
Reserved
Program as shown above.
Program as shown above.
Program as shown above.
1:0
72
Preliminary Rev. 0.81
Si2107/08/09/10
Register 8Eh. Spectrum Tilt Correction Threshold Register (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
SPEC_TILT_CORREC[7:0]
Function
D3
D2
D1
D0
Name
Bit
Name
7:0 SPEC_TILT_CORREC[7:0] Correction to be applied for spectrum tilt.
Refer to Silicon Laboratories application note AN298 for recommended
default values for QuickLock/QuickScan operation.
Register 90h. 1dB Bandwidth Threshold Register (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
BW_1dB
D3
D2
D1
D0
Name
Bit
Name
BW_1dB[7:0]
Function
Threshold used to determine 1 dB bandwidth for a detected channel.
7:0
Refer to Silicon Laboratories application note AN298 for recommended
default values for QuickLock/QuickScan operation.
Register 91h. 2dB Bandwidth Threshold Register (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
BW_2dB
D3
D2
D1
D0
Name
Bit
Name
Function
7:0
BW_2dB[7:0]
Threshold used to determine 2 dB bandwidth for a detected channel.
Refer to Silicon Laboratories application note AN298 for recommended default val-
ues for QuickLock/QuickScan operation.
Register 92h. 3dB Bandwidth Threshold Register (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
BW_3dB
D3
D2
D1
D0
Name
Bit
Name
BW_3dB[7:0]
Function
Threshold used to determine 3 dB bandwidth for a detected channel.
7:0
Refer to Silicon Laboratories application note AN298 for recommended
default values for QuickLock/QuickScan operation.
Preliminary Rev. 0.81
73
Si2107/08/09/10
Register 93h. Inband Power Threshold Register (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
INBAND_THRESHOLD
Bit
Name
Function
Threshold for determining the drop in power in a channel as the LSA scans a
7:0
INBAND_
THRESHOLD[7:0] detected channel to determine the channel bandwidth.
Refer to Silicon Laboratories application note AN298 for recommended default val-
ues for QuickLock/QuickScan operation.
Register 94h. Noise Level Margin Threshold Register (Si2109 and Si2110 only)
Bit
D7
D6
D5
D4
REF_NOISE_MARGIN[7:0]
Function
D3
D2
D1
D0
Name
Bit
Name
7:0 REF_NOISE_MARGIN[7:0] Power level threshold for the detection of channels.
Refer to Silicon Laboratories application note AN298 for recommended
default values for QuickLock/QuickScan operation.
Register A0h. Viterbi Search Control 1
Bit
D7
D6
D5
D4
D3
D2
D1
D0
0
0
VTCS[5:0]
Name
Bit
Name
Function
7:6
5:0
Reserved
VTCS[5:0]
Program as shown above.
Viterbi Code Rate Search Parameter Enable.
The code rates to be used in the Viterbi search are selected by writing a
one into the appropriate bit position. The list below illustrates the rela-
tionship between bit position and code rate.
Bit 5 = 7/8 code rate (MSB)
Bit 4 = 6/7 code rate
Bit 3 = 5/6 code rate
Bit 2 = 3/4 code rate
Bit 1 = 2/3 code rate
Bit 0 = 1/2 code rate (LSB)
Default: All code rates selected (3Fh).
74
Preliminary Rev. 0.81
Si2107/08/09/10
Register A2h. Viterbi Search Control 2
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
0
0
0
VTERS
VTERM
VTERW[1:0]
Bit
7:4
3
Name
Function
Reserved
VTERS
Program as shown above.
Viterbi BER Measurement Start
Writing a 1 to this bit initiates the Viterbi BER measurement.
2
VTERM
Viterbi BER Measurement Mode
0 = finite window (default)
1 = infinite window
1:0
VTERW[1:0]
Viterbi BER Measurement Window
13
00 = 2 bits (default)
17
01 = 2 bits
21
10 = 2 bits
25
11 = 2 bits
Register A3h. Viterbi Search Status
Bit
D7
D6
D5
D4
D3
D2
D1
D0
VTRS[2:0]
0
VTPS
VTIQS
Name
0
0
Bit
Name
Function
7:5
VTRS[2:0]
Viterbi Current Code Rate Status.
000 = 1/2 code rate (default)
001 = 2/3 code rate
010 = 3/4 code rate
011 = 5/6 code rate
100 = 6/7 code rate
101 = 7/8 code rate
11x = Undefined
4:2
1
Reserved
VTPS
Program as shown above.
Viterbi Constellation Rotation Phase Status.
0 = Not rotated (default)
1 = Rotated by 90 degrees
Viterbi I/Q Swap Status.
0
VTIQS
0 = Not swapped (default)
1 = Swapped
Preliminary Rev. 0.81
75
Si2107/08/09/10
Register ABh. Viterbi BER Count L
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
VTERC[7:0]
Bit
Name
VTERC[7:0]
Function
7:0
Viterbi BER Counter (Low Byte).
Stores the number of the Viterbi bit errors detected within the specified
measurement window. This register saturates when it reaches the limit
of its range.
Default: 00h
Register ACh. Viterbi BER Count H
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
VTERC[15:8]
Bit
Name
VTERC[15:8]
Function
7:0
Viterbi BER Counter (High Byte).
See Register ABh.
76
Preliminary Rev. 0.81
Si2107/08/09/10
Register B0h. Reed-Solomon BER Error Monitor Control
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
0
0
RSERS
RSERM
RSERW
RSERT[1:0]
Bit
7:5
4
Name
Function
Reserved
RSERS
Program as shown above.
Reed-Solomon BER Measurement Start.
Writing a 1 to this bit initiates the Reed-Solomon BER measurement.
3
2
RSERM
RSERW
Reed-Solomon Measurement Mode.
0 = Finite window (default)
1 = Infinite window
Reed-Solomon Measurement Window.
12
0 = 2 frames (default)
16
1 = 2 frames
1:0
RSERT[1:0]
Reed-Solomon Error Type.
00 = Corrected bit errors (default)
01 = Corrected byte errors
10 = Uncorrected packets
11 = PRBS errors
Register B1h. Reed-Solomon Error Monitor Count L
D7
D6
D5
D4
D3
D2
D1
D0
Bit
RSERC[7:0]
Name
Bit
Name
RSERC[7:0]
Function
7:0
Reed-Solomon Error Counter (Low Byte).
Stores the number of RS or PRBS errors detected within the specified
window. This register saturates when it reaches the limit of its range.
Default: 00h
Preliminary Rev. 0.81
77
Si2107/08/09/10
Register B2h. Reed-Solomon Error Monitor Count H
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
RSERC[15:8]
Bit
Name
RSERC[15:8]
Function
7:0
Reed-Solomon Error Counter (High Byte).
See Register B1h.
Register B3h. Descrambler Control
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
0
0
0
0
0
DST_DS
DSO_DS
Bit
7:2
1
Name
Function
Reserved
DST_DS
Program as shown above.
Descrambler Transport Error Insertion Disable.
0 = Enabled (default)
1 = Disabled
0
DSO_DS
Descrambler Inverted SYNC Overwrite Disable.
0 = Enabled (default)
1 = Disabled
78
Preliminary Rev. 0.81
Si2107/08/09/10
Register B5h. PRBS Control
Bit D7
Name PRBS_START PRBS_INVERT PRBS_SYNC
D6
D5
D4
D3
D2
D1
D0
0
0
0
PRBS_HEADER_SIZE[1:0]
Bit
Name
Function
7
PRBS_START
Start PRBS Synchronization.
1 = Start PRBS synchronization
Default = 0
6
5
PRBS_INVERT
PRBS_SYNC
Invert PRBS Output.
1 = PRBS inverted.
Default = 0
Synchronization Achieved for PRBS Test.
0 = Not synchronized.
1 = Synchronized
Default = 0
4:2
1:0
Reserved
Read returns zero.
PRBS_HEADER_SIZE
Packet Header Size.
This signals the number of bytes at the start of a TS packet that are con-
sidered TS header, and that are not occupied by PRBS data in PRBS
test mode.
DVB-Smode
00 = 1
DSS mode
0 (Default)
01 = 2
10 = 3
11 = 4
1
2
3
Preliminary Rev. 0.81
79
Si2107/08/09/10
Register C0h. LNB Control 1
Bit
D7
D6
0
D5
D4
Si2107/9
LNBB
Si2108/10
LNBB
D3
D2
D1
D0
Part
LNBS
LNBS
LNBCT
LNBCT
MMSG
MSGL[2:0]
MSGL[2:0]
Name
Part
LNBV
MMSG
Name
Bit
Name
Function
7
LNBS
LNB Start.
Writing a 1 to this bit initiates an LNB signaling sequence. This bit is automatically
cleared to zero when the sequence is complete.
Note: Not available in manual LNB mode.
6
5
LNBV
LNB DC Voltage Selection.
0 = 13 V (default)
1 = 18 V
LNBCT
Continuous Tone Selection.
0 = Normal operation (default)
1 = Send continuous tone
Note: Not available in manual LNB mode.
4
3
LNBB
Tone Burst Selection.
0 = Unmodulated tone burst (default)
1 = Modulated tone burst
Note: For use in automatic LNB mode only. Use a 1-byte DiSEqC message for tone burst
implementation in step-by-step LNB mode.
MMSG
More Messages.
0 = Normal operation (default)
1 = Indicates more DiSEqC messages to be sent
This bit is automatically cleared to zero when the sequence is complete.
Note: For use in automatic LNB mode only.
2:0
MSGL[2:0] Message Length.
000 = No message (default)
001 = One byte
010 = Two bytes
011 = Three bytes
100 = Four bytes
101 = Five bytes
110 = Six bytes
111 = Longer than six bytes.
Notes:
1. When message length is set to one byte, tone burst modulation is used. When message
length is set to two or more bytes, DiSEqC modulation is used.
2. Not available in manual LNB mode.
80
Preliminary Rev. 0.81
Si2107/08/09/10
Register C1h. LNB Control 2
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
LNBM[1:0]
0
0
0
BRST_DS
TFS
0
Bit
Name
Function
7:6
LNBM[1:0]
LNB Signaling Mode.
00 = Automatic (default)
01 = Step-by-step
10 = Manual
11 = Reserved
5:3
2
Reserved
BRST_DS
Program as shown above.
Tone Burst Disable.
0 = Enabled (default)
1 = Disabled
Note: For use in automatic LNB mode only, in conjunction with LNBB (C0h[4])
1
0
TFS
Tone Format Select.
0 = Tone generation/detection (default)
1 = Envelope generation/detection
Reserved
Program as shown above.
Register C2h. LNB Control 3
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
TDIR
TT
TR
0
0
0
0
0
Bit
Name
Function
7
TDIR
Tone Direction Control.
Controls output of DRC pin.
0 = Low (logic zero) (default)
1 = High (logic one)
Note: This bit is only active in manual LNB mode.
6
5
TT
TR
Tone Transmit.
Controls output of TGEN pin.
0 = Tone off / Low (logic zero) (default)
1 = Tone on / High (logic one)
Note: This bit is only active in manual LNB mode.
Tone Receive.
Detects input on TDET pin.
0 = No tone or low signal detected (default)
1 = Tone or high signal detected
Note: This bit is only active in manual LNB mode.
4:0
Reserved
Program as shown above.
Preliminary Rev. 0.81
81
Si2107/08/09/10
Register C3h. LNB Control 4
Bit
D7
D6
D5
D4
D3
D2
D1
D1
Name
TFQ[7:0]
Bit
Name
TFQ[7:0]
Function
LNB Tone Frequency Control.
7
Used to set the frequency of the LNB tone according to the following
equation:
Frequency = 100 MHz/[32 x (TFQ+1)]
00000000–01111011 = Reserved
01111100–10011011 = valid range
10011100–11111111 = Reserved
Default: 8Dh = 22 kHz
82
Preliminary Rev. 0.81
Si2107/08/09/10
Register C4h. LNB Status
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
FE
FF
MSGPE
MSGR
MSGTO
MSGRL[2:0]
Bit
Name
Function
Message FIFO Empty.
7
FE
0 = Normal operation (default)
1 = Message FIFO empty
Message FIFO Full.
6
FF
0 = Normal operation (default)
1 = Message FIFO full
Message Parity Error.
5
MSGPE
MSGR
0 = Normal operation (default)
1 = Parity error detected
Message Received.
4
0 = Normal operation (default)
1 = Message received
Message Timeout.
3
MSGTO
0 = Normal operation (default)
1 = Message reply not received within 150 ms
Received Message Length.
2:0
MSGRL[2:0]
000 = No message (default)
001 = One byte
010 = Two bytes
011 = Three bytes
100 = Four bytes
101 = Five bytes
110 = Six bytes
111 = Longer than six bytes
Preliminary Rev. 0.81
83
Si2107/08/09/10
Register C5-CAh. Message FIFO 1–6
Bit
D7
D6
D5
D4
FIF0x[7:0]
D3
D2
D1
D0
Name
Bit
Name
FIFO1–6[7:0]
Function
7:0
Message FIFO.
Contains message to be transmitted or message received
Register CBh. LNB Supply Control 1 (Si2108 and Si2110 only)
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
VLOW[3:0]
VHIGH[3:0]
Bit
Name
Function
7:4
VLOW[3:0]
LNB Supply Low Voltage.
Low voltage = Vlow_nom + VLOW[3:0] x 0.0625V + Vboost, where
Vlow_nom is determined by the LNBV(C0h[6]) register bit, and Vboost
is determined by the COMP(CEh[2]) register bit.
Default: Low voltage = Vlow_nom + 0.0 V + Vboost.
3:0
VHIGH[3:0]
LNB Supply High Voltage.
High voltage = Vhigh_nom + VHIGH[3:0] x 0.0625V + Vboost, where
Vhigh_nom is determined by the LNBV(C0h[6]) register bit, and
Vboost is determined by the COMP(CEh[2]) register bit.
Default: High voltage = Vhigh_nom + 0.0 V + Vboost.
84
Preliminary Rev. 0.81
Si2107/08/09/10
Register CCh. LNB Supply Control 2 (Si2108 and Si2110 only)
Bit
D7
D6
D5
D4
D3
SLOT[1:0]
Function
D2
D1
D0
Name
ILIM[1:0]
IMAX[1:0]
OLOT[1:0]
Bit
Name
7:6
ILIM[1:0]
IMAX[1:0]
SLOT[1:0]
Average Current Limit.
00 = 400 – 550 mA (default)
01 = 500 – 650 mA
10 = 650 – 850 mA
11 = 800 – 1000 mA
5:4
3:2
Peak Current Limit.
00 = 1.2 A (default)
01 = 1.6 A
10 = 2.4 A
11 = 3.2 A
Short Circuit Lockout Time.
00 = 15 µs initial; 240 µs secondary
01 = 20 µs initial; 320 µs secondary (default)
10 = 40 µs initial; 480 µs secondary
11 = 20 µs
Overcurrent Lockout Time.
00 = 2.5 ms
1:0
OLOT[1:0]
01 = 3.75 ms
10 = 5.0 ms (default)
11 = 7.5 ms
Note: This register byte is read-only if LNBL=1.
Register CDh. LNB Supply Control 3 (Si2108 and Si2110 only)
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
VMON[7:0]
Bit
Name
VMON[7:0]
Function
7:0
LNB Voltage Monitor (read only).
LNB output voltage = VMON x 0.0625 + 6 V
Preliminary Rev. 0.81
85
Si2107/08/09/10
Register CEh. LNB Supply Control 4 (Si2108 and Si2110 only)
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
LNBL
0
0
0
LNB_EN
COMP
0
LNBMD
Bit
Name
Function
7
LNBL
LNB Supply Lock.
Writing a one to this bit locks the contents of Register CCh. This bit
can only be cleared by a device reset.
6:4
3
Reserved
LNB_EN
Program as shown above.
LNB Supply Enable.
0 = Disabled (default)
1 = Enabled
2
COMP
LNB Cable Compensation Boost.
0 = Normal operation (default)
1 = LNB output voltage increased +1 V
1
0
Reserved
LNBMD
Program as shown above.
LNB Mode Detect.
Detected supply mode (read-only)
0 = External LNB supply circuit
1 = Internal LNB supply circuit
Register CFh. LNB Supply Status (Si2108 and Si2110 only)
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
0
0
0
0
0
0
SCD
OCD
Bit
Name
Function
7:2
1
Reserved
SCD
Program as shown above.
Short-Circuit Detect Flag.
0 = Normal operation (default)
1 = Short-circuit detected
0
OCD
Overcurrent Detect Flag.
0 = Normal operation (default)
1 = Overcurrent detected.
86
Preliminary Rev. 0.81
Si2107/08/09/10
9. Pin Descriptions
Si2108/10
Si2107/09
44 43 42 41 40 39 38 37 36
44 43 42 41 40 39 38 37 36
1
2
3
4
5
6
7
8
9
VDD_LNA
REXT
1
2
3
4
5
6
7
8
9
35 XTAL1
VDD_LNA
REXT
35 XTAL1
XTAL2
GND
GND
34 XTAL2
34
ADDR
33 VDD_XTAL
32 XTOUT
ADDR
33 VDD_XTAL
32 XTOUT
VDD_MIX
VDD_BB
VDD_ADC
VSEN/TDET
LNB1/TGEN
ISEN
VDD_MIX
VDD_BB
VDD_ADC
TDET
31 VDD_PLL33
30 INT/RLK/GPO
29 TS_ERR
31 VDD_PLL33
30 INT/RLK/GPO
29 TS_ERR
Top
View
Top
View
TGEN
28
27
28
TS_VAL
TS_VAL
NC
27 TS_SYNC
26 SDA
TS_SYNC
LNB2/DRC 10
RESET 11
DRC 10
11
26 SDA
RESET
25 SCL
25 SCL
PWM/DCS
DCS 12
12
24 TS_DATA[7]
24 TS_DATA[7]
GND
GND
TS_DATA[6]
23
TS_DATA[6]
23
VDD_DIG18 13
VDD_DIG18 13
14 15 16 17 18 19 20 21 22
14 15 16 17 18 19 20 21 22
Pin #
Name
I/O
Description
Supply Voltage.
1
VDD_LNA
I
LNA power supply. Connect to 3.3 V.
External Reference Resistor.
Connect 4.53 kΩ to GND.
2
3
4
REXT
ADDR
I
I
I
2
I C Address Select.
Supply Voltage.
Mixer power supply. Connect to 3.3 V
Supply Voltage.
Baseband power supply. Connect to 1.8 V.
Supply Voltage.
ADC power supply. Connect to 3.3 V.
Voltage Sense/Tone Detect.
VDD_MIX
5
6
VDD_BB
I
I
VDD_ADC
7
8
9
VSEN/TDET
LNB1/TGEN
ISEN
I
O
I
VSEN (Si2108/10 only)—Line voltage of LNB supply circuit.
TDET—Detect input of external tone or tone envelope.
LNB Control 1/Tone Generation.
LNB1 (Si2108/10 only)—Required connection to LNB supply circuit.
TGEN—Outputs tone or tone envelope.
Current Sense (Si2108/10 only).
Monitors current of LNB supply circuit. When LNB supply circuit is not populated or
when using Si2107/09, leave pin unconnected.
LNB Control 2/Direction Control.
LNB2 (Si2108/10 only)—required connection to LNB supply circuit.
DRC—Outputs signal to indicate message transmission (HIGH) or reception
(LOW).
10
11
LNB2/DRC
RESET
O
I
Device Reset.
Active low.
Preliminary Rev. 0.81
87
Si2107/08/09/10
Pin #
Name
I/O
Description
PWM/DC Voltage Select.
PWM (Si2108/10 only)—Connected to gate of power MOSFET for LNB supply cir-
12
PWM/DCS
O
cuit.
DCS—Outputs signal to indicate 18 V (HIGH) or 13 V (LOW) LNB supply voltage
selection.
Supply voltage.
13
VDD_DIG18
TS_DATA[7:0]
VDD_DIG33
I
O
I
Digital power supply. Connect to 1.8 V.
Transport Stream Data Bus.
Serial data is output on TS_DATA[0].
Supply Voltage.
14–17,
21–24
18, 20
Digital power supply. Connect to 3.3 V.
19
25
26
27
28
29
TS_CLK
SCL
O
I
Transport Stream Clock.
2
I C Clock.
2
SDA
I/O I C Data.
TS_SYNC
TS_VAL
TS_ERR
O
O
O
Transport Stream Sync.
Transport Stream Valid.
Transport Stream Error.
Multi Purpose Output Pin.
This pin can be configured to one of the following outputs using the Pin Ctrl 2 (05h)
register.
INT = Interrupt
INT/RLK/
GPO
30
O
RLK = Receiver lock indicator
GPO = General purpose output
Supply Voltage.
Analog PLL power supply. Connect to 3.3 V.
31
32
VDD_PLL33
XTOUT
I
No Connect/Crystal oscillator output.
If this device is to be used as the clock master in a multi-channel design, this pin
should be connect to the XTAL1 pin of a clock slave device. (Otherwise, this pin
should be left unconnected.)
O
Supply Voltage.
Crystal Oscillator power supply. Connect to 3.3 V.
Crystal Oscillator.
Connect to 20 MHz crystal unit.
Crystal Oscillator.
Connect to 20 MHz crystal unit.
Supply Voltage.
Synth power supply. Connect to 3.3 V.
Supply Voltage.
Local Oscillator power supply. Connect to 3.3 V.
Ground.
33
34
VDD_XTAL
XTAL2
I
O
I
35
XTAL1
36
VDD_SYNTH
VDD_LO
GND
I
37
I
38,41,44
I
Reference ground.
RF Input.
39, 43 RFIP1, RFIP2
40, 42 RFIN1, RFIN2
I
These pins must be connected together on the board.
RF Input.
These pins must be connected together on the board.
Ground.
I
ePad
GND
I
Reference ground.
88
Preliminary Rev. 0.81
Si2107/08/09/10
10. Ordering Guide1,2
Ordering Part #
Description
Temperature
Si2110-X-FM
Si2109-X-FM
Si2108-X-FM
Si2107-X-FM
Satellite receiver for DVB-S/DSS with LNB step-up dc-dc controller
and on-chip blindscan accelerator, Pb-free and RoHS Compliant
0 to 70 °C
0 to 70 °C
0 to 70 °C
0 to 70 °C
Satellite receiver for DVB-S/DSS with on-chip blindscan accelerator,
Pb-free and RoHS Compliant
Satellite receiver for DVB-S/DSS with step-up dc-dc controller, Pb-
free and RoHS Compliant
Satellite receiver for DVB-S/DSS, Pb-free and RoHS Compliant
Notes:
1. “X” denotes product revision.
2. Add an “R” at the end of the device to denote tape and reel option; 2500 quantity per reel.
Preliminary Rev. 0.81
89
Si2107/08/09/10
11. Package Outline: 44-pin QFN
Figure 23 illustrates the package details for the Si2110. Table 20 lists the values for the dimensions shown in the
illustration.
Figure 23. 44-Pin QFN
Table 20. Package Diagram Dimensions
Millimeters
Nom
Millimeters
Nom
Dimension
Dimension
Min
Max
Min
Max
A
0.80
0.00
0.18
0.90
0.02
1.00
0.05
0.30
E2
L
6.00
0.45
0.03
6.10
0.55
0.05
0.10
0.10
0.08
0.10
6.20
0.65
0.08
A1
b
0.25
L1
D
D2
6.00 BSC.
2.80
aaa
bbb
ccc
ddd
2.70
2.90
e
0.50 BSC.
8.00 BSC.
E
Notes:
1. Dimensioning and tolerancing per ANSI Y14.5M-1994.
2. This drawing conforms to the JEDEC Solid State Outline MO-220, Variation VJLD.
3. Recommended card reflow profile is per the JEDEC/IPC J-STD-020C specification for small body Components.
4. The pin 1 I.D. pad is for component orientation only and is not to be soldered to the PCB.
90
Preliminary Rev. 0.81
Si2107/08/09/10
12. PCB Land Pattern
Figure 24. PCB Land Pattern
Preliminary Rev. 0.81
91
Si2107/08/09/10
Table 21. PCB Land Pattern Dimensions
Dimension
Min
Max
e
E
0.50 BSC
7.51 REF
5.51 REF
D
E2
D2
GE
GD
X
6.00
2.70
6.71
4.71
—
6.20
2.90
--
--
0.28
Y
0.80 REF
ZE
ZD
—
—
8.31
6.31
Notes - General:
1. All dimensions shown are in millimeters (mm) unless otherwise noted.
2. Dimensioning and Tolerancing is per the ANSI Y14.5M-1994 specification.
3. This Land Pattern Design is based on IPC-SM-782 guidelines.
4. All dimensions shown are at Maximum Material Condition (MMC). Least
Material Condition (LMC) is calculated based on a Fabrication Allowance of
0.05 mm.
Notes - Solder Mask Design:
1. All metal pads are to be non-solder mask defined (NSMD). Clearance between
the solder mask and the metal pad is to be 60 m minimum, all the way around
the pad.
Notes - Stencil Design:
1. A stainless steel, laser-cut and electro-polished stencil with trapezoidal walls
should be used to assure good solder paste release.
2. The stencil thickness should be 0.125mm (5 mils).
3. The ratio of stencil aperture to land pad size should be 1:1 for the perimeter
pads.
4. A 3x6 array of 0.70mm square openings on 0.95mm pitch should be used for
the center ground pad.
Notes - Card Assembly:
1. A No-Clean, Type-3 solder paste is recommended.
2. The recommended card reflow profile is per the JEDEC/IPC J-STD-020C
specification for Small Body Components.
92
Preliminary Rev. 0.81
Si2107/08/09/10
DOCUMENT CHANGE LIST
Revision 0.4 to Revision 0.5
ꢀ Package dimensions changed to 6 x 8 mm.
ꢀ Updated pin numbering and pin descriptions.
ꢀ Schematics updated.
2
ꢀ I C interface description added.
ꢀ MPEG-TS timing specifications added.
Revision 0.5 to revision 0.6
ꢀ Data sheet for Si2107/08/09/10.
ꢀ Added detailed operational description.
ꢀ Register map changed for Rev. C silicon.
ꢀ Various editorial changes and corrections.
Revision 0.6 to revision 0.7
ꢀ Updated application diagram and BOM.
2
ꢀ Added table for multi-device I C address support.
Revision 0.7 to revision 0.8
ꢀ Added detailed operational description of QuickScan
functionality in "6.9. On-Chip Blindscan Controller:
QuickScan (Si2109/10 Only)" on page 32.
ꢀ Added graphs of performance illustrating typical
performance.
ꢁ Figure 4, “Eb/No (QEF Operation) vs. Input Power for
Si2107/08/09/10 (Typical) SR = 27.5 MBaud, CR = 7/8,”
on page 11.
ꢁ Figure 5, “BER After Viterbi vs. Eb/No for Si2107/08/09/
10,” on page 11.
ꢁ Figure 6, “Phase Noise Performance for Si2107/08/09/
10 (Typical),” on page 12.
ꢀ Updated “2. Typical Application Schematics”.
ꢁ Figure 8, “Si2107/08/09/10 Schematic,” on page 13
ꢁ Figure 9, “DiSEqC 1.x LNB Supply Circuit,” on page 14
ꢁ Figure 10, “DiSEqC 2.x LNB Supply Circuit,” on page
15.
ꢀ Updated "3. Bill of Materials" on page 16.
ꢀ Added "12. PCB Land Pattern" on page 91.
Revision 0.8 to revision 0.81
ꢀ Updated documentation on Quicklock and
QuickScan details.
ꢀ Added Figure 7, “Frequency Offset vs. Carrier Lock/
Acquisition Time for Various Baudrates Using
QuickLock (Typical),” on page 12.
Preliminary Rev. 0.81
93
Si2107/08/09/10
CONTACT INFORMATION
Silicon Laboratories Inc.
4635 Boston Lane
Austin, TX 78735
Tel: 1+(512) 416-8500
Fax: 1+(512) 416-9669
Toll Free: 1+(877) 444-3032
Email: DBSinfo@silabs.com
Internet: www.silabs.com
The information in this document is believed to be accurate in all respects at the time of publication but is subject to change without notice.
Silicon Laboratories assumes no responsibility for errors and omissions, and disclaims responsibility for any consequences resulting from
the use of information included herein. Additionally, Silicon Laboratories assumes no responsibility for the functioning of undescribed features
or parameters. Silicon Laboratories reserves the right to make changes without further notice. Silicon Laboratories makes no warranty, rep-
resentation or guarantee regarding the suitability of its products for any particular purpose, nor does Silicon Laboratories assume any liability
arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation conse-
quential or incidental damages. Silicon Laboratories products are not designed, intended, or authorized for use in applications intended to
support or sustain life, or for any other application in which the failure of the Silicon Laboratories product could create a situation where per-
sonal injury or death may occur. Should Buyer purchase or use Silicon Laboratories products for any such unintended or unauthorized ap-
plication, Buyer shall indemnify and hold Silicon Laboratories harmless against all claims and damages.
Silicon Laboratories and Silicon Labs are trademarks of Silicon Laboratories Inc.
Other products or brandnames mentioned herein are trademarks or registered trademarks of their respective holders.
94
Preliminary Rev. 0.81