SI7020-A20-GMR [SILICON]

Serial Switch/Digital Sensor, 14 Bit(s), 0.40Cel, Square, Surface Mount, DFN-6;
SI7020-A20-GMR
型号: SI7020-A20-GMR
厂家: SILICON    SILICON
描述:

Serial Switch/Digital Sensor, 14 Bit(s), 0.40Cel, Square, Surface Mount, DFN-6

输出元件 传感器 换能器
文件: 总36页 (文件大小:1441K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Si7020-A20  
I2C HUMIDITY AND TEMPERATURE SENSOR  
Features  
Precision Relative Humidity Sensor  
Factory-calibrated  
 ± 4% RH (max), 0–80% RH  
High Accuracy Temperature Sensor  
±0.4 °C (max), –10 to 85 °C  
0 to 100% RH operating range  
Up to –40 to +125 °C operating  
range  
Wide operating voltage  
(1.9 to 3.6 V)  
Low Power Consumption  
150 µA active current  
60 nA standby current  
I2C Interface  
Integrated on-chip heater  
3x3 mm DFN Package  
Excellent long term stability  
Optional factory-installed cover  
Low-profile  
Protection during reflow  
Excludes liquids and particulates  
Ordering Information:  
See page 29.  
Applications  
Pin Assignments  
Top View  
HVAC/R  
Micro-environments/data centers  
Automotive climate control and  
Thermostats/humidistats  
Respiratory therapy  
White goods  
defogging  
Asset and goods tracking  
Mobile phones and tablets  
Indoor weather stations  
SDA  
GND  
1
2
3
6
5
4
SCL  
VDD  
DNC  
Description  
The Si7020 I2C Humidity and Temperature Sensor is a monolithic CMOS IC  
integrating humidity and temperature sensor elements, an analog-to-digital  
converter, signal processing, calibration data, and an I2C Interface. The patented  
use of industry-standard, low-K polymeric dielectrics for sensing humidity enables  
the construction of low-power, monolithic CMOS Sensor ICs with low drift and  
hysteresis, and excellent long term stability.  
DNC  
Patent Protected. Patents pending  
The humidity and temperature sensors are factory-calibrated and the calibration  
data is stored in the on-chip non-volatile memory. This ensures that the sensors  
are fully interchangeable, with no recalibration or software changes required.  
The Si7020 is available in a 3x3 mm DFN package and is reflow solderable. It can  
be used as a hardware- and software-compatible drop-in upgrade for existing RH/  
temperature sensors in 3x3 mm DFN-6 packages, featuring precision sensing  
over a wider range and lower power consumption. The optional factory-installed  
cover offers a low profile, convenient means of protecting the sensor during  
assembly (e.g., reflow soldering) and throughout the life of the product, excluding  
liquids (hydrophobic/oleophobic) and particulates.  
The Si7020 offers an accurate, low-power, factory-calibrated digital solution ideal  
for measuring humidity, dew-point, and temperature, in applications ranging from  
HVAC/R and asset tracking to industrial and consumer platforms.  
Rev. 1.2 8/16  
Copyright © 2016 by Silicon Laboratories  
Si7020-A20  
Si7020-A20  
Functional Block Diagram  
Vdd  
Si7020  
1.25V  
Ref  
Calibration  
Memory  
Humidity  
Sensor  
Control Logic  
ADC  
Temp  
Sensor  
SDA  
SCL  
I2C Interface  
GND  
2
Rev. 1.2  
Si7020-A20  
TABLE OF CONTENTS  
Section  
Page  
1. Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4  
2. Typical Application Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12  
3. Bill of Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13  
4. Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14  
4.1. Relative Humidity Sensor Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15  
4.2. Hysteresis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16  
4.3. Prolonged Exposure to High Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16  
4.4. PCB Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16  
4.5. Protecting the Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18  
4.6. Bake/Hydrate Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18  
4.7. Long Term Drift/Aging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18  
5. I2C Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19  
5.1. Issuing a Measurement Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20  
5.2. Reading and Writing User Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24  
5.3. Electronic Serial Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24  
5.4. Firmware Revision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25  
5.5. Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25  
6. Control Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26  
6.1. Register Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26  
7. Pin Descriptions: Si7020 (Top View) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28  
8. Ordering Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29  
9. Package Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30  
9.1. Package Outline: 3x3 6-pin DFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30  
9.2. Package Outline: 3x3 6-pin DFN with Protective Cover . . . . . . . . . . . . . . . . . . . . . .31  
10. PCB Land Pattern and Solder Mask Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32  
11. Top Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33  
11.1. Si7020 Top Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33  
11.2. Top Marking Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33  
12. Additional Reference Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34  
Document Change List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35  
Rev. 1.2  
3
Si7020-A20  
1. Electrical Specifications  
Unless otherwise specified, all min/max specifications apply over the recommended operating conditions.  
Table 1. Recommended Operating Conditions  
Symbol  
VDD  
TA  
Test Condition  
Min  
1.9  
Typ  
Max  
3.6  
Unit  
V
Parameter  
Power Supply  
Operating Temperature  
Operating Temperature  
I and Y grade  
G grade  
–40  
–40  
+125  
+85  
°C  
°C  
TA  
Table 2. General Specifications  
1.9 < VDD < 3.6 V; TA = –40 to 85 °C (G grade) or –40 to 125 °C (I/Y grade); default conversion time unless otherwise noted.  
Parameter  
Symbol  
Test Condition  
SCL, SDA pins  
Min  
0.7xVDD  
Typ  
Max  
Unit  
V
Input Voltage High  
Input Voltage Low  
Input Voltage Range  
Input Leakage  
V
IH  
VIL  
VIN  
IIL  
SCL, SDA pins  
0.3xVDD  
VDD  
1
V
SCL, SDA pins with respect to GND  
SCL, SDA pins  
0.0  
V
μA  
V
Output Voltage Low  
VOL  
SDA pin; IOL = 2.5 mA; VDD = 3.3 V  
0.6  
SDA pin; IOL = 1.2 mA;  
VDD = 1.9 V  
0.4  
V
Current  
Consumption  
IDD  
RH conversion in progress  
150  
90  
180  
120  
0.62  
3.8  
4.0  
4.0  
μA  
μA  
Temperature conversion in progress  
2
Standby, –40 to +85 °C  
0.06  
μA  
2
Standby, –40 to +125 °C  
0.06  
μA  
3
Peak IDD during powerup  
3.5  
mA  
mA  
mA  
2
4
Peak IDD during I C operations  
3.5  
5
Heater Current  
I
3.1 to 94.2  
HEAT  
Notes:  
1. Initiating a RH measurement will also automatically initiate a temperature measurement. The total conversion time will  
be tCONV(RH) + tCONV(T).  
2. No conversion or I2C transaction in progress. Typical values measured at 25 °C.  
3. Occurs once during powerup. Duration is <5 msec.  
4. Occurs during I2C commands for Reset, Read/Write User Registers, Read EID, and Read Firmware Version. Duration is  
<100 µs when I2C clock speed is >100 kHz (>200 kHz for 2-byte commands).  
5. Additional current consumption when HTRE bit enabled. See Section “5.5. Heater” for more information.  
4
Rev. 1.2  
 
 
 
 
 
 
Si7020-A20  
Table 2. General Specifications (Continued)  
1.9 < VDD < 3.6 V; TA = –40 to 85 °C (G grade) or –40 to 125 °C (I/Y grade); default conversion time unless otherwise noted.  
Parameter  
Symbol  
Test Condition  
12-bit RH  
Min  
Typ  
10  
5.8  
3.7  
2.6  
7
Max  
12  
Unit  
1
Conversion Time  
tCONV  
11-bit RH  
7
10-bit RH  
4.5  
3.1  
10.8  
6.2  
3.8  
2.4  
25  
8-bit RH  
ms  
14-bit temperature  
13-bit temperature  
12-bit temperature  
11-bit temperature  
4
2.4  
1.5  
18  
Powerup Time  
tPU  
From VDD 1.9 V to ready for a  
conversion, 25 °C  
From VDD 1.9 V to ready for a  
conversion, full temperature range  
5
80  
15  
ms  
After issuing a software reset  
command  
Notes:  
1. Initiating a RH measurement will also automatically initiate a temperature measurement. The total conversion time will  
be tCONV(RH) + tCONV(T).  
2. No conversion or I2C transaction in progress. Typical values measured at 25 °C.  
3. Occurs once during powerup. Duration is <5 msec.  
4. Occurs during I2C commands for Reset, Read/Write User Registers, Read EID, and Read Firmware Version. Duration is  
<100 µs when I2C clock speed is >100 kHz (>200 kHz for 2-byte commands).  
5. Additional current consumption when HTRE bit enabled. See Section “5.5. Heater” for more information.  
Rev. 1.2  
5
Si7020-A20  
Table 3. I2C Interface Specifications1  
1.9 VDD 3.6 V; TA = –40 to +85 °C (G grade) or –40 to +125 °C (I/Y grade) unless otherwise noted.  
Parameter  
Hysteresis  
Symbol  
Test Condition  
Min  
Typ  
Max  
Unit  
V
High-to-low versus low-to- 0.05 x V  
high transition  
V
HYS  
DD  
2
SCLK Frequency  
SCL High Time  
SCL Low Time  
Start Hold Time  
Start Setup Time  
Stop Setup Time  
Bus Free Time  
SDA Setup Time  
SDA Hold Time  
SDA Valid Time  
f
400  
kHz  
µs  
µs  
µs  
µs  
µs  
µs  
ns  
ns  
µs  
µs  
ns  
SCL  
t
0.6  
1.3  
0.6  
0.6  
0.6  
SKH  
t
SKL  
t
STH  
t
STS  
SPS  
BUF  
t
t
Between Stop and Start  
1.3  
100  
100  
t
DS  
DH  
t
t
From SCL low to data valid  
From SCL low to data valid  
0.9  
0.9  
VD;DAT  
VD;ACK  
SDA Acknowledge Valid Time  
t
3
Suppressed Pulse Width  
t
50  
SPS  
Notes:  
1. All values are referenced to VIL and/or VIH.  
2. Depending on the conversion command, the Si7020 may hold the master during the conversion (clock stretch). At  
above 100 kHz SCL, the Si7020 may also hold the master briefly for user register and device ID transactions. At the  
highest I2C speed of 400 kHz the stretching will be <50 µs.  
3. Pulses up to and including 50 ns will be suppressed.  
tSKH  
tSKL  
1/fSCL  
tSP  
SCL  
SDA  
tBUF  
tSTH  
tDS  
tDH  
tSPS  
D6  
D5  
D4  
D0  
R/W  
ACK  
Start Bit  
tSTS  
Stop Bit  
tVD  
:
ACK  
Figure 1. I2C Interface Timing Diagram  
6
Rev. 1.2  
 
 
 
 
 
Si7020-A20  
Table 4. Humidity Sensor  
1.9 VDD 3.6 V; TA = 30 °C; default conversion time unless otherwise noted.  
Parameter  
Symbol  
Test Condition  
Non-condensing  
0 – 80% RH  
Min  
0
Typ  
Max  
100  
±4  
Unit  
%RH  
%RH  
1
Operating Range  
±3  
2, 3  
Accuracy  
80 – 100% RH  
See Figure 2.  
0.025  
0.05  
Repeatability/Noise  
12-bit resolution  
11-bit resolution  
%RH RMS  
10-bit resolution  
0.1  
8-bit resolution  
0.2  
1 m/s airflow, with cover  
1 m/s airflow, without cover  
18  
4
Response Time  
τ
S
63%  
17  
Drift vs. Temperature  
Hysteresis  
0.05  
%RH/°C  
%RH  
±1  
3
Long Term Stability  
< 0.25  
%RH/yr  
Notes:  
1. Recommended humidity operating range is 20% to 80% RH (non-condensing) over –10 °C to 60 °C. Prolonged  
operation beyond these ranges may result in a shift of sensor reading, with slow recovery time.  
2. Excludes hysteresis, long term drift, and certain other factors and is applicable to non-condensing environments only.  
See Section “4.1. Relative Humidity Sensor Accuracy” for more details.  
3. Drift due to aging effects at typical room conditions of 30 °C and 30% to 50% RH. May be impacted by dust, vaporized  
solvents or other contaminants, e.g., out-gassing tapes, adhesives, packaging materials, etc. See Section “4.7. Long  
Term Drift/Aging” .  
4. Response time to a step change in RH. Time for the RH output to change by 63% of the total RH change.  
Rev. 1.2  
7
 
 
 
 
 
Si7020-A20  
Figure 2. RH Accuracy at 30 °C  
8
Rev. 1.2  
Si7020-A20  
Table 5. Temperature Sensor  
1.9 VDD 3.6 V; TA = –40 to +85 °C (G grade) or –40 to +125 °C (I/Y grade) default conversion time, unless otherwise noted.  
Parameter  
Symbol  
Test Condition  
I and Y Grade  
G Grade  
Min  
–40  
–40  
Typ  
Max  
+125  
+85  
Unit  
°C  
Operating Range  
°C  
1
Accuracy  
–10 °C< t < 85 °C  
±0.3  
Figure 3.  
0.01  
0.02  
0.04  
0.08  
0.7  
±0.4  
°C  
A
–40 < t < 125 °C  
A
Repeatability/Noise  
14-bit resolution  
13-bit resolution  
12-bit resolution  
11-bit resolution  
Unmounted device  
Si7020-EB board  
°C RMS  
2
Response Time  
τ
s
63%  
5.1  
s
Long Term Stability  
0.01  
°C/Yr  
Notes:  
1. 14b measurement resolution (default).  
2. Time to reach 63% of final value in response to a step change in temperature. Actual response time will vary  
dependent on system thermal mass and air-flow.  
Rev. 1.2  
9
 
 
 
Si7020-A20  
Figure 3. Temperature Accuracy*  
*Note: Applies only to I and Y grade devices beyond +85 °C.  
10  
Rev. 1.2  
Si7020-A20  
Table 6. Thermal Characteristics  
Parameter  
Symbol  
Test Condition  
DFN-6  
Unit  
Junction to Air Thermal Resistance  
JEDEC 2-Layer board,  
No Airflow  
256  
°C/W  
JA  
Junction to Air Thermal Resistance  
Junction to Air Thermal Resistance  
JEDEC 2-Layer board,  
1 m/s Airflow  
224  
205  
°C/W  
°C/W  
JA  
JEDEC 2-Layer board,  
2.5 m/s Airflow  
JA  
Junction to Case Thermal Resistance  
Junction to Board Thermal Resistance  
JEDEC 2-Layer board  
JEDEC 2-Layer board  
22  
°C/W  
°C/W  
JC  
134  
JB  
Table 7. Absolute Maximum Ratings1  
Parameter  
Symbol  
Test Condition  
Min  
Typ  
Max  
Unit  
Ambient temperature  
under bias  
–55  
125  
°C  
2
Storage Temperature  
Voltage on I/O pins  
–65  
–0.3  
–0.3  
150  
°C  
V
V
+0.3 V  
DD  
Voltage on VDD with  
respect to GND  
4.2  
V
ESD Tolerance  
HBM  
CDM  
MM  
2
kV  
kV  
V
1.25  
250  
Notes:  
1. Absolute maximum ratings are stress ratings only, operation at or beyond these conditions is not implied and may  
shorten the life of the device or alter its performance.  
2. Special handling considerations apply; see application note, “AN607: Si70xx Humidity Sensor Designer’s Guide”.  
Rev. 1.2  
11  
 
 
Si7020-A20  
2. Typical Application Circuits  
The primary function of the Si7020 is to measure relative humidity and temperature. Figure 4 demonstrates the  
typical application circuit to achieve these functions.  
1.9 to 3.6V  
0.1µF  
10k  
10k  
5
VDD  
6
1
SCL  
SDA  
SCL  
SDA  
Si7020  
GND  
2
Figure 4. Typical Application Circuit for Relative Humidity and Temperature Measurement  
12  
Rev. 1.2  
 
Si7020-A20  
3. Bill of Materials  
Table 8. Typical Application Circuit BOM for Relative Humidity and Temperature Measurement  
Reference  
Description  
Mfr Part Number  
CR0603-16W-103JT  
CR0603-16W-103JT  
C0603X7R160-104M  
Si7020-A20-GM  
Manufacturer  
Venkel  
R1  
R2  
C1  
U1  
Resistor, 10 k, ±5%, 1/16 W, 0603  
Resistor, 10 k, ±5%, 1/16 W, 0603  
Capacitor, 0.1 µF, 16 V, X7R, 0603  
IC, Digital Temperature/humidity Sensor  
Venkel  
Venkel  
Silicon Labs  
Rev. 1.2  
13  
Si7020-A20  
4. Functional Description  
Vdd  
Si7020  
1.25V  
Ref  
Calibration  
Memory  
Humidity  
Sensor  
Control Logic  
ADC  
Temp  
Sensor  
SDA  
SCL  
I2C Interface  
GND  
Figure 5. Si7020 Block Diagram  
The Si7020 is a digital relative humidity and temperature sensor that integrates temperature and humidity sensor  
elements, an analog-to-digital converter, signal processing, calibration, polynomial non-linearity correction, and an  
2
I C interface all in a single chip. The Si7020 is individually factory-calibrated for both temperature and humidity,  
with the calibration data stored in on-chip non-volatile memory. This ensures that the sensor is fully  
interchangeable, with no recalibration or changes to software required. Patented use of industry-standard CMOS  
and low-K dielectrics as a sensor enables the Si7020 to achieve excellent long term stability and immunity to  
contaminants with low drift and hysteresis. The Si7020 offers a low-power, high-accuracy, calibrated and stable  
solution ideal for a wide range of temperature, humidity, and dew-point applications including medical and  
instrumentation, high-reliability automotive and industrial systems, and cost-sensitive consumer electronics.  
While the Si7020 is largely a conventional mixed-signal CMOS integrated circuit, relative humidity sensors in  
general and those based on capacitive sensing using polymeric dielectrics have unique application and use  
requirements that are not common to conventional (non-sensor) ICs. Chief among those are:  
The need to protect the sensor during board assembly, i.e., solder reflow, and the need to subsequently  
rehydrate the sensor.  
The need to protect the senor from damage or contamination during the product life-cycle.  
The impact of prolonged exposure to extremes of temperature and/or humidity and their potential effect on  
sensor accuracy.  
The effects of humidity sensor “memory”.  
Each of these items is discussed in more detail in the following sections.  
14  
Rev. 1.2  
Si7020-A20  
4.1. Relative Humidity Sensor Accuracy  
To determine the accuracy of a relative humidity sensor, it is placed in a temperature and humidity controlled  
chamber. The temperature is set to a convenient fixed value (typically 25–30 °C) and the relative humidity is swept  
from 20 to 80% and back to 20% in the following steps: 20% – 40% – 60% – 80% – 80% – 60% – 40% – 20%. At  
each set-point, the chamber is allowed to settle for a period of 60 minutes before a reading is taken from the  
sensor. Prior to the sweep, the device is allowed to stabilize to 50%RH. The solid trace in Figure 6, “Measuring  
Sensor Accuracy Including Hysteresis,” shows the result of a typical sweep.  
Figure 6. Measuring Sensor Accuracy Including Hysteresis  
The RH accuracy is defined as the dotted line shown in Figure 6, which is the average of the two data points at  
each relative humidity set-point. In this case, the sensor shows an accuracy of 0.25%RH. The Si7020 accuracy  
specification (Table 4) includes:  
Unit-to-unit and lot-to-lot variation  
Accuracy of factory calibration  
Margin for shifts that can occur during solder reflow  
The accuracy specification does not include:  
Hysteresis (typically ±1%)  
Effects from long term exposure to very humid conditions  
Contamination of the sensor by particulates, chemicals, etc.  
Other aging related shifts ("Long-term stability")  
Variations due to temperature (see Drift vs. Temperature in Table 4). RH readings will typically vary with  
temperature by less than 0.05% C.  
Rev. 1.2  
15  
 
Si7020-A20  
4.2. Hysteresis  
The moisture absorbent film (polymeric dielectric) of the humidity sensor will carry a memory of its exposure  
history, particularly its recent or extreme exposure history. A sensor exposed to relatively low humidity will carry a  
negative offset relative to the factory calibration, and a sensor exposed to relatively high humidity will carry a  
positive offset relative to the factory calibration. This factor causes a hysteresis effect illustrated by the solid trace  
in Figure 6. The hysteresis value is the difference in %RH between the maximum absolute error on the decreasing  
humidity ramp and the maximum absolute error on the increasing humidity ramp at a single relative humidity  
setpoint and is expressed as a bipolar quantity relative to the average error (dashed trace). In the example of  
Figure 6, the measurement uncertainty due to the hysteresis effect is ±1.0%RH.  
4.3. Prolonged Exposure to High Humidity  
Prolonged exposure to high humidity will result in a gradual upward drift of the RH reading. The shift in sensor  
reading resulting from this drift will generally disappear slowly under normal ambient conditions. The amount of  
shift is proportional to the magnitude of relative humidity and the length of exposure. In the case of lengthy  
exposure to high humidity, some of the resulting shift may persist indefinitely under typical conditions. It is generally  
possible to substantially reverse this affect by baking the device (see Section “4.6. Bake/Hydrate Procedure” ).  
4.4. PCB Assembly  
4.4.1. Soldering  
Like most ICs, Si7020 devices are shipped from the factory vacuum-packed with an enclosed desiccant to avoid  
any RH accuracy drift during storage and to prevent any moisture-related issues during solder reflow. The following  
guidelines should be observed during PCB assembly:  
Si7020 devices are compatible with standard board assembly processes. Devices should be soldered  
using reflow per the recommended card reflow profile. See Section “10. PCB Land Pattern and Solder  
Mask Design” for the recommended card reflow profile.  
A "no clean" solder process is recommended to minimize the need for water or solvent rinses after  
soldering. Cleaning after soldering is possible, but must be done carefully to avoid impacting the  
performance of the sensor. See “AN607: Si70xx Humidity Sensor Designer’s Guide” for more information  
on cleaning.  
It is essential that the exposed polymer sensing film be kept clean and undamaged. This can be  
accomplished by careful handling and a clean, well-controlled assembly process. When in doubt or for  
extra protection, a heat-resistant, protective cover such as Kapton™ KPPD-1/8 polyimide tape can be  
installed during PCB assembly.  
Si7020s may be ordered with a factory-fitted, solder-resistant protective cover. This cover provides protection  
during PCB assembly or rework but without the time and effort required to install and remove the Kapton tape. It  
can be left in place for the lifetime of the product, preventing liquids, dust or other contaminants from coming into  
contact with the polymer sensor film. See Section “8. Ordering Guide” for a list of ordering part numbers that  
include the cover.  
4.4.2. Rehydration  
The measured humidity value will generally shift slightly after solder reflow. A portion of this shift is permanent and  
is accounted for in the accuracy specifications in Table 4. After soldering, an Si7020 should be allowed to  
equilibrate under controlled RH conditions (room temperature, 45–55%RH) for at least 48 hours to eliminate the  
remainder of the shift and return the device to its specified accuracy performance.  
16  
Rev. 1.2  
Si7020-A20  
4.4.3. Rework  
To maintain the specified sensor performance, care must be taken during rework to minimize the exposure of the  
device to excessive heat and to avoid damage/contamination or a shift in the sensor reading due to liquids, solder  
flux, etc. Manual touch-up using a soldering iron is permissible under the following guidelines:  
The exposed polymer sensing film must be kept clean and undamaged. A protective cover is  
recommended during any rework operation (Kapton® tape or the factory installed cover).  
Flux must not be allowed to contaminate the sensor; liquid flux is not recommended even with a cover in  
place. Conventional lead-free solder with rosin core is acceptable for touch-up as long as a cover is in  
place during the rework.  
If possible, avoid water or solvent rinses after touch-up. Cleaning after soldering is possible, but must be  
done carefully to avoid impacting the performance of the sensor. See “AN607: Si70xx Humidity Sensor  
Designer’s Guide” for more information on cleaning.  
Minimize the heating of the device. Soldering iron temperatures should not exceed 350 °C and the contact  
time per pin should not exceed five seconds.  
Hot air rework is not recommended. If a device must be replaced, remove the device by hot air and solder  
a new part in its place by reflow following the guidelines above.  
*Note: All trademarks are the property of their respective owners.  
Figure 7. Si7020 with Factory-Installed Protective Cover  
Rev. 1.2  
17  
Si7020-A20  
4.5. Protecting the Sensor  
Because the sensor operates on the principal of measuring a change in capacitance, any changes to the dielectric  
constant of the polymer film will be detected as a change in relative humidity. Therefore, it is important to minimize  
the probability of contaminants coming into contact with the sensor. Dust and other particles as well as liquids can  
affect the RH reading. It is recommended that a cover is employed in the end system that blocks contaminants but  
allows water vapor to pass through. Depending on the needs of the application, this can be as simple as plastic or  
metallic gauze for basic protection against particulates or something more sophisticated such as a hydrophobic  
membrane providing up to IP67 compliant protection.  
The Si7020 may be ordered with a factory-fitted, solder-resistant cover that can be left in place for the lifetime of  
the product. It is very low-profile, hydrophobic and oleophobic. See Section “8. Ordering Guide” for a list of  
ordering part numbers that include the cover. A dimensioned drawing of the IC with the cover is included in Section  
“9. Package Outline” . Other characteristics of the cover are listed in Table 9.  
Table 9. Specifications of Protective Cover  
Parameter  
Value  
PTFE  
Material  
Operating Temperature  
–40 to 125 °C  
260 °C  
Maximum Reflow Temperature  
IP Rating (per IEC 529)  
IP67  
4.6. Bake/Hydrate Procedure  
After exposure to extremes of temperature and/or humidity for prolonged periods, the polymer sensor film can  
become either very dry or very wet, in each case the result is either high or low relative humidity readings. Under  
normal operating conditions, the induced error will diminish over time. From a very dry condition, such as after  
shipment and soldering, the error will diminish over a few days at typical controlled ambient conditions, e.g.,  
48 hours of 45 %RH 55. However, from a very wet condition, recovery may take significantly longer. To  
accelerate recovery from a wet condition, a bake and hydrate cycle can be implemented. This operation consists of  
the following steps:  
Baking the sensor at 125 °C for 12 hours  
Hydration at 30 °C in 75% RH for 10 hours  
Following this cycle, the sensor will return to normal operation in typical ambient conditions after a few days.  
4.7. Long Term Drift/Aging  
Over long periods of time, the sensor readings may drift due to aging of the device. Standard accelerated life  
testing of the Si7020 has resulted in the specifications for long-term drift shown in Table 4 and Table 5. This  
contribution to the overall sensor accuracy accounts only for the long-term aging of the device in an otherwise  
benign operating environment and does not include the effects of damage, contamination, or exposure to extreme  
environmental conditions.  
18  
Rev. 1.2  
 
 
Si7020-A20  
5. I2C Interface  
2
The Si7020 communicates with the host controller over a digital I C interface. The 7-bit base slave address is  
0x40.  
2
Table 10. I C Slave Address Byte  
A6  
A5  
A4  
A3  
A2  
A1  
A0  
R/W  
1
0
0
0
0
0
0
0
2
2
Master I C devices communicate with the Si7020 using a command structure. The commands are listed in the I C  
command table. Commands other than those documented below are undefined and should not be sent to the  
device.  
Table 11. I2C Command Table  
Command Description  
Measure Relative Humidity, Hold Master Mode  
Command Code  
0xE5  
Measure Relative Humidity, No Hold Master Mode  
Measure Temperature, Hold Master Mode  
Measure Temperature, No Hold Master Mode  
Read Temperature Value from Previous RH Measurement  
Reset  
0xF5  
0xE3  
0xF3  
0xE0  
0xFE  
Write RH/T User Register 1  
0xE6  
Read RH/T User Register 1  
0xE7  
Write Heater Control Register  
0x51  
Read Heater Control Register  
0x11  
Read Electronic ID 1st Byte  
0xFA 0x0F  
0xFC 0xC9  
0x84 0xB8  
Read Electronic ID 2nd Byte  
Read Firmware Revision  
Rev. 1.2  
19  
Si7020-A20  
5.1. Issuing a Measurement Command  
The measurement commands instruct the Si7020 to perform one of two possible measurements; Relative Humidity  
or Temperature. The procedure to issue any one of these commands is identical. While the measurement is in  
progress, the option of either clock stretching (Hold Master Mode) or Not Acknowledging read requests (No Hold  
Master Mode) is available to indicate to the master that the measurement is in progress; the chosen command  
code determines which mode is used.  
Optionally, a checksum byte can be returned from the slave for use in checking for transmission errors. The  
checksum byte will follow the least significant measurement byte if it is acknowledged by the master. The  
checksum byte is not returned if the master “not acknowledges” the least significant measurement byte. The  
8
5
4
checksum byte is calculated using a CRC generator polynomial of x + x + x + 1, with an initialization of 0x00.  
The checksum byte is optional after initiating an RH or temperature measurement with commands 0xE5, 0xF5,  
0xE3, and 0xF3. The checksum byte is required for reading the electronic ID with commands 0xFA 0x0F and 0xFC  
0xC9. For all other commands, the checksum byte is not supported.  
Table 12. I2C Bit Descriptions  
Name  
Symbol  
Description  
START  
S
P
SDA goes low while SCL high.  
SDA goes high while SCL high.  
STOP  
Repeated START  
Sr  
SDA goes low while SCL high. It is allowable to generate a STOP before the  
repeated start. SDA can transition to high before or after SCL goes high in  
preparation for generating the START.  
READ  
R
W
Read bit = 1  
Write bit = 0  
WRITE  
All other bits  
SDA value must remain high or low during the entire time SCL is high (this is  
the set up and hold time in Figure 1).  
2
In the I C sequence diagrams in the following sections, bits produced by the master and slave are color coded as  
shown:  
Master  
Slave  
20  
Rev. 1.2  
 
 
Si7020-A20  
Sequencetoperformameasurementandreadbackresult(HoldMasterMode)ꢀ  
Clockstretchꢀ  
duringꢀ  
measurementꢀ  
Slaveꢀ  
Addressꢀ  
Measureꢀ  
Cmdꢀ  
Slaveꢀ  
Addressꢀ  
Sꢀ  
WAꢀ  
ASrꢀ  
RAꢀ  
ꢀꢀ  
ꢀꢀ  
MSByteꢀ  
Aꢀ  
LSByteꢀ  
NAPꢀ  
AChecksumNA Pꢀ  
Note: Device will NACK the slave address byte until conversion is complete.  
Rev. 1.2  
21  
Si7020-A20  
5.1.1. Measuring Relative Humidity  
Once a relative humidity measurement has been made, the results of the measurement may be converted to  
percent relative humidity by using the following expression:  
125 RH_Code  
%RH = --------------------------------------- 6  
65536  
Where:  
%RH is the measured relative humidity value in %RH  
RH_Code is the 16-bit word returned by the Si7020  
A humidity measurement will always return XXXXXX10 in the LSB field.  
Due to normal variations in RH accuracy of the device as described in Table 4, it is possible for the measured value  
of %RH to be slightly less than 0 when the actual RH level is close to or equal to 0. Similarly, the measured value  
of %RH may be slightly greater than 100 when the actual RH level is close to or equal to 100. This is expected  
behavior, and it is acceptable to limit the range of RH results to 0 to 100%RH in the host software by truncating  
values that are slightly outside of this range.  
5.1.2. Measuring Temperature  
Each time a relative humidity measurement is made a temperature measurement is also made for the purposes of  
temperature compensation of the relative humidity measurement. If the temperature value is required, it can be  
read using command 0xE0; this avoids having to perform a second temperature measurement. The measure  
temperature commands 0xE3 and 0xF3 will perform a temperature measurement and return the measurement  
value, command 0xE0 does not perform a measurement but returns the temperature value measured during the  
relative humidity measurement.  
The checksum output is not available with the 0xE0 command.  
SequencetoreadtemperaturevaluefrompreviousRHmeasurementꢀ  
Slave  
Addressꢀ  
Slaveꢀ  
Addressꢀ  
Sꢀ  
WAꢀ  
0xE0ꢀ  
ASrꢀ  
RAꢀ  
MSByteꢀ  
Aꢀ  
LSByteꢀ  
NAPꢀ  
22  
Rev. 1.2  
Si7020-A20  
The results of the temperature measurement may be converted to temperature in degrees Celsius (°C) using the  
following expression:  
175.72 Temp_Code  
Temperature (C= ------------------------------------------------------- 46.85  
65536  
Where:  
Temperature (°C) is the measured temperature value in °C  
Temp_Code is the 16-bit word returned by the Si7020  
A temperature measurement will always return XXXXXX00 in the LSB field.  
Rev. 1.2  
23  
Si7020-A20  
5.2. Reading and Writing User Registers  
There is one user register on the Si7020 that allows the user to set the configuration of the Si7020. The procedure  
for accessing that register is described below.  
The checksum byte is not supported after reading a user register.  
Sequence to read a register  
Slave  
Read Reg  
Cmd  
Slave  
S
W
A
A
Sr  
R
A
Read Data  
NA  
P
Address  
Address  
Sequence to write a register  
Write Reg Cmd  
S
Slave Address  
W
A
A
Write Data  
A
P
5.3. Electronic Serial Number  
2
The Si7020 provides a serial number individualized for each device that can be read via the I C serial interface.  
2
Two I C commands are required to access the device memory and retrieve the complete serial number. The  
command sequence, and format of the serial number response is described in the figure below:  
Master  
Slave  
First access:  
S
S
Slave Address  
Slave Address  
SNA_3  
W
R
ACK  
ACK  
CRC  
CRC  
0xFA  
ACK  
0X0F  
ACK  
ACK  
ACK  
ACK  
ACK  
SNA_2  
SNA_0  
ACK  
ACK  
CRC  
CRC  
ACK  
SNA_1  
NACK  
P
2nd access:  
S
S
Slave Address  
Slave Address  
SNB_3  
W
R
ACK  
ACK  
0xFC  
ACK  
0XC9  
ACK  
P
ACK  
ACK  
SNB_2  
SNB_0  
ACK  
ACK  
CRC  
CRC  
ACK  
SNB_1  
NACK  
The format of the complete serial number is 64-bits in length, divided into 8 data bytes. The complete serial number  
sequence is shown below:  
SNA_3  
SNA_2  
SNA_1  
SNA_0  
SNB_3  
SNB_2  
SNB_1  
SNB_0  
The SNB3 field contains the device identification to distinguish between the different Silicon Labs relative humidity  
and temperature devices. The value of this field maps to the following devices according to this table:  
24  
Rev. 1.2  
Si7020-A20  
0x00 or 0xFF engineering samples  
0x0D=13=Si7013  
0x14=20=Si7020  
0x15=21=Si7021  
5.4. Firmware Revision  
2
The internal firmware revision can be read with the following I C transaction:  
Slave  
Slave  
S
W
A
0x84  
A
0xB8  
A
S
Address  
Address  
R
A
FWREV  
NA  
P
The values in this field are encoded as follows:  
0xFF = Firmware version 1.0  
0x20 = Firmware version 2.0  
5.5. Heater  
The Si7020 contains an integrated resistive heating element that may be used to raise the temperature of the  
sensor. This element can be used to test the sensor, to drive off condensation, or to implement dew-point  
measurement when the Si7020 is used in conjunction with a separate temperature sensor such as another Si7020  
(the heater will raise the temperature of the internal temperature sensor).  
The heater can be activated using HTRE, bit 2 in User Register 1. Turning on the heater will reduce the tendency  
of the humidity sensor to accumulate an offset due to "memory" of sustained high humidity conditions. Several  
different power levels are available. The various settings are adjusted using the Heater Control Register and are  
described in the following table.  
Table 13. Heater Control Settings  
*
HEATER[3:0]  
Typical Current Draw (mA)  
0000  
0001  
0010  
...  
3.09  
9.18  
15.24  
...  
0100  
...  
27.39  
...  
1000  
...  
51.69  
...  
1111  
94.20  
*Note: Assumes VDD = 3.3 V.  
Rev. 1.2  
25  
 
Si7020-A20  
6. Control Registers  
Table 14. Register Summary  
Register  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
User Register 1  
RES1  
VDDS  
RSVD  
RSVD  
RSVD  
HTRE  
RSVD  
RES0  
Heater Control  
Register  
RSVD  
HEATER[3:0]  
Notes:  
1. Any register not listed here is reserved and must not be written. The result of a read operation on these bits is  
undefined.  
2. Except where noted, reserved register bits will always read back as “1,” and are not affected by write operations. For  
future compatibility, it is recommended that prior to a write operation, registers should be read. Then the values read  
from the RSVD bits should be written back unchanged during the write operation.  
6.1. Register Descriptions  
Register 1. User Register 1  
Bit  
D7  
D6  
VDDS  
R
D5  
D4  
D3  
D2  
D1  
D0  
Name  
Type  
RES1  
R/W  
RSVD  
R/W  
RSVD  
RSVD  
HTRE  
R/W  
RSVD  
R/W  
RES0  
R/W  
R/W  
Reset Settings = 0011_1010  
Bit  
Name  
Function  
D7; D0  
RES[1:0]  
Measurement Resolution:  
RH  
Temp  
14 bit  
12 bit  
13 bit  
11 bit  
00:  
01:  
10:  
11:  
12 bit  
8 bit  
10 bit  
11 bit  
D6  
VDDS  
V
Status:  
DD  
0:  
1:  
V
V
OK  
Low  
DD  
DD  
The minimum recommended operating voltage is 1.9 V. A transi-  
tion of the V status bit from 0 to 1 indicates that V is  
DD  
DD  
between 1.8 V and 1.9 V. If the V drops below 1.8 V, the  
DD  
device will no longer operate correctly.  
D5, D4, D3  
D2  
RSVD  
HTRE  
Reserved  
1 = On-chip Heater Enable  
0 = On-chip Heater Disable  
D1  
RSVD  
Reserved  
26  
Rev. 1.2  
Si7020-A20  
Register 2. Heater Control Register  
Bit  
D7  
D6  
D5  
D4  
D3  
D2  
Heater [3:0]  
R/W  
D1  
D0  
Name  
Type  
RSVD  
R/W  
Reset Settings = 0000_0000  
Bit  
Name  
Function  
D3:D0 HEATER[3:0]  
D3  
0
D2  
D1  
0
D0  
0
Heater Current  
0
0
0
3.09 mA  
9.18 mA  
15.24 mA  
0
0
1
0
1
0
...  
0
0
1
1
0
1
0
0
1
27.39 mA  
...  
0
51.69 mA  
94.20 mA  
...  
1
1
D7,D6,  
D5,D4  
RSVD  
Reserved  
Rev. 1.2  
27  
Si7020-A20  
7. Pin Descriptions: Si7020 (Top View)  
SDA  
GND  
1
2
3
6
5
4
SCL  
VDD  
DNC  
DNC  
Pin Name  
SDA  
Pin #  
Pin Description  
2
1
2
I C data  
GND  
Ground. This pin is connected to ground on the circuit board through a trace. Do not  
connect directly to GND plane.  
VDD  
SCL  
DNC  
5
6
Power. This pin is connected to power on the circuit board.  
2
I C clock  
3,4  
These pins should be soldered to pads on the PCB for mechanical stability; they can be  
electrically floating or tied to V (do not tie to GND).  
DD  
T
Paddle This pad is connected to GND internally. This pad is the main thermal input to the  
GND  
on-chip temperature sensor. The paddle should be soldered to a floating pad.  
28  
Rev. 1.2  
Si7020-A20  
8. Ordering Guide  
Table 15. Device Ordering Guide  
P/N  
Description  
Max.  
Pkg  
Operating  
Protective Packing  
Accuracy  
Range (°C)  
Cover  
Format  
Temp  
RH  
Si7020-A20-GM Digital temperature/ humidity sensor  
Si7020-A20-GMR Digital temperature/ humidity sensor  
Si7020-A20-GM1 Digital temperature/ humidity sensor  
Si7020-A20-GM1R Digital temperature/ humidity sensor  
±0.4 °C ± 4% DFN 6  
±0.4 °C ± 4% DFN 6  
±0.4 °C ± 4% DFN 6  
±0.4 °C ± 4% DFN 6  
–40 to +85 °C  
–40 to +85 °C  
–40 to +85 °C  
–40 to +85 °C  
N
N
Y
Y
N
N
Y
Y
N
N
Y
Y
Cut  
Tape  
Tape &  
Reel  
Cut  
Tape  
Tape &  
Reel  
Si7020-A20-IM  
Digital temperature/ humidity sensor – ±0.4 °C ± 4% DFN 6 –40 to +125 °C  
industrial temp range  
Cut  
Tape  
Si7020-A20-IMR Digital temperature/ humidity sensor – ±0.4 °C ± 4% DFN 6 –40 to +125 °C  
industrial temp range  
Tape &  
Reel  
Si7020-A20-IM1 Digital temperature/ humidity sensor – ±0.4 °C ± 4% DFN 6 –40 to +125 °C  
industrial temp range  
Cut  
Tape  
Si7020-A20-IM1R Digital temperature/ humidity sensor – ±0.4 °C ± 4% DFN 6 –40 to +125 °C  
industrial temp range  
Tape &  
Reel  
Si7020-A20-YM0 Digital temperature/ humidity sensor – ±0.4 °C ± 4% DFN 6 –40 to +125 °C  
automotive  
Cut  
Tape  
Si7020-A20-YM0R Digital temperature/ humidity sensor – ±0.4 °C ± 4% DFN 6 –40 to +125 °C  
automotive  
Tape &  
Reel  
Si7020-A20-YM1 Digital temperature/ humidity sensor – ±0.4 °C ± 4% DFN 6 –40 to +125 °C  
automotive  
Cut  
Tape  
Si7020-A20-YM1R Digital temperature/ humidity sensor – ±0.4 °C ± 4% DFN 6 –40 to +125 °C  
automotive  
Tape &  
Reel  
Note: The “A” denotes product revision A and “20” denotes firmware version 2.0.  
Rev. 1.2  
29  
Si7020-A20  
9. Package Outline  
9.1. Package Outline: 3x3 6-pin DFN  
Figure 10. 3x3 6-pin DFN  
Table 16. 3x3 6-pin DFN Package Diagram Dimensions  
Dimension  
Min  
Nom  
Max  
A
A1  
b
0.70  
0.00  
0.35  
0.75  
0.02  
0.80  
0.05  
0.45  
0.40  
D
3.00 BSC.  
1.50  
D2  
e
1.40  
1.60  
1.00 BSC.  
3.00 BSC.  
2.40  
E
E2  
H1  
H2  
L
2.30  
0.85  
1.39  
0.35  
2.50  
0.95  
1.49  
0.45  
0.90  
1.44  
0.40  
aaa  
bbb  
ccc  
ddd  
eee  
fff  
0.10  
0.10  
0.05  
0.10  
0.05  
0.05  
Notes:  
1. All dimensions shown are in millimeters (mm).  
2. Dimensioning and Tolerancing per ANSI Y14.5M-1994.  
30  
Rev. 1.2  
Si7020-A20  
9.2. Package Outline: 3x3 6-pin DFN with Protective Cover  
Figure 8 illustrates the package details for the Si7020 with the optional protective cover. The table below lists the  
values for the dimensions shown in the illustration.  
Figure 8. 3x3 6-pin DFN with Protective Cover  
Table 17. 3x3 6-pin DFN with Protective Cover Package Diagram Dimensions  
Dimension  
Min  
Nom  
Max  
1.21  
0.05  
0.80  
0.45  
A
A1  
A2  
b
0.00  
0.70  
0.35  
0.02  
0.75  
0.40  
D
3.00 BSC.  
1.50  
D2  
e
1.40  
1.60  
1.00 BSC.  
3.00 BSC.  
2.40  
E
E2  
F1  
F2  
h
2.30  
2.70  
2.70  
0.76  
0.35  
0.45  
2.50  
2.90  
2.90  
0.90  
0.45  
0.55  
2.80  
2.80  
0.83  
L
0.40  
R1  
aaa  
bbb  
ccc  
ddd  
eee  
0.50  
0.10  
0.10  
0.05  
0.10  
0.05  
Notes:  
1. All dimensions are shown in millimeters (mm).  
2. Dimensioning and Tolerancing per ANSI Y14.5M-1994.  
Rev. 1.2  
31  
 
 
Si7020-A20  
10. PCB Land Pattern and Solder Mask Design  
Figure 9. Si7020 PCB Land Pattern  
Table 18. PCB Land Pattern Dimensions  
Symbol  
C1  
mm  
2.90  
1.00  
1.60  
2.50  
0.45  
0.85  
E
P1  
P2  
X1  
Y1  
Notes:  
General  
1. All dimensions shown are at Maximum Material Condition (MMC). Least Material  
Condition (LMC) is calculated based on a Fabrication Allowance of 0.05 mm.  
2. This Land Pattern Design is based on the IPC-7351 guidelines.  
Solder Mask Design  
3. All metal pads are to be non-solder mask defined (NSMD). Clearance between the  
solder mask and the metal pad is to be 60 µm minimum, all the way around the  
pad.  
Stencil Design  
4. A stainless steel, laser-cut and electro-polished stencil with trapezoidal walls  
should be used to assure good solder paste release.  
5. The stencil thickness should be 0.125 mm (5 mils).  
6. The ratio of stencil aperture to land pad size should be 1:1 for all perimeter pins.  
7. A 2x1 array of 1.00 mm square openings on 1.30 mm pitch should be used for the  
center ground pad to achieve a target solder coverage of 50%.  
Card Assembly  
8. The recommended card reflow profile is per the JEDEC/IPC J-STD-020  
specification for Small Body Components.  
32  
Rev. 1.2  
 
Si7020-A20  
11. Top Marking  
11.1. Si7020 Top Marking  
11.2. Top Marking Explanation  
Mark Method:  
Font Size  
Laser  
0.30 mm  
Pin 1 Indicator:  
Line 1 Marking:  
Circle = 0.30 mm Diameter  
Upper-Left Corner  
TTTT = Mfg Code  
Rev. 1.2  
33  
Si7020-A20  
12. Additional Reference Resources  
AN607: Si70xx Humidity Sensor Designer’s Guide  
34  
Rev. 1.2  
Si7020-A20  
DOCUMENT CHANGE LIST  
Revision 0.9 to Revision 0.91  
Updated Table 2 on page 4.  
Revision 0.91 to Revision 1.0  
Updated document revision to 1.0.  
Revision 1.0 to Revision 1.1  
Updated note 2 in Table 3.  
Updated Section 4.5.  
Updated Table 9.  
2
Corrected a typo in the I C sequence for no-hold  
mode in Section 5.1.  
Corrected a typo in Table 12.  
Updated Table 17, dimensions F1 and F2.  
Revision 1.1 to Revision 1.2  
Updated diagram in "5.4. Firmware Revision" on  
page 25.  
Updated notes in Table 18, “PCB Land Pattern  
Dimensions,” on page 32.  
Changed packing format from tube to cut tape for all  
non-tape & reel part numbers without protective filter  
covers.  
Rev. 1.2  
35  
Smart.  
Connected.  
Energy-Friendly  
Products  
www.silabs.com/products  
Quality  
www.silabs.com/quality  
Support and Community  
community.silabs.com  
Disclaimer  
Silicon Laboratories intends to provide customers with the latest, accurate, and in-depth documentation of all peripherals and modules available for system and software implementers  
using or intending to use the Silicon Laboratories products. Characterization data, available modules and peripherals, memory sizes and memory addresses refer to each specific  
device, and "Typical" parameters provided can and do vary in different applications. Application examples described herein are for illustrative purposes only. Silicon Laboratories  
reserves the right to make changes without further notice and limitation to product information, specifications, and descriptions herein, and does not give warranties as to the accuracy  
or completeness of the included information. Silicon Laboratories shall have no liability for the consequences of use of the information supplied herein. This document does not imply  
or express copyright licenses granted hereunder to design or fabricate any integrated circuits. The products must not be used within any Life Support System without the specific  
written consent of Silicon Laboratories. A "Life Support System" is any product or system intended to support or sustain life and/or health, which, if it fails, can be reasonably expected  
to result in significant personal injury or death. Silicon Laboratories products are generally not intended for military applications. Silicon Laboratories products shall under no  
circumstances be used in weapons of mass destruction including (but not limited to) nuclear, biological or chemical weapons, or missiles capable of delivering such weapons.  
Trademark Information  
Silicon Laboratories Inc., Silicon Laboratories, Silicon Labs, SiLabs and the Silicon Labs logo, CMEMS®, EFM, EFM32, EFR, Energy Micro, Energy Micro logo and combinations  
thereof, "the world’s most energy friendly microcontrollers", Ember®, EZLink®, EZMac®, EZRadio®, EZRadioPRO®, DSPLL®, ISOmodem ®, Precision32®, ProSLIC®, SiPHY®,  
USBXpress® and others are trademarks or registered trademarks of Silicon Laboratories Inc. ARM, CORTEX, Cortex-M3 and THUMB are trademarks or registered trademarks of  
ARM Holdings. Keil is a registered trademark of ARM Limited. All other products or brand names mentioned herein are trademarks of their respective holders.  
Silicon Laboratories Inc.  
400 West Cesar Chavez  
Austin, TX 78701  
USA  
http://www.silabs.com  

相关型号:

Si7020-A20-IM

IC HUMIDITY AND TEMPERATURE SENSOR
SILICON

Si7020-A20-IM1

IC HUMIDITY AND TEMPERATURE SENSOR
SILICON

Si7020-A20-IM1R

IC HUMIDITY AND TEMPERATURE SENSOR
SILICON

Si7020-A20-IMR

IC HUMIDITY AND TEMPERATURE SENSOR
SILICON

SI7020-A20-YM0

IC HUMIDITY AND TEMPERATURE SENSOR
SILICON

SI7020-A20-YM0R

IC HUMIDITY AND TEMPERATURE SENSOR
SILICON

SI7020-A20-YM1

IC HUMIDITY AND TEMPERATURE SENSOR
SILICON

SI7020-A20-YM1R

IC HUMIDITY AND TEMPERATURE SENSOR
SILICON

SI7021

IC HUMIDITY AND TEMPERATURE SENSOR
SILICON

Si7021-A10-GM

This change is considered a minor change which does not affect form, fit, function, quality, or reliability.
SILICON

Si7021-A10-GM1

This change is considered a minor change which does not affect form, fit, function, quality, or reliability.
SILICON

Si7021-A10-GM1R

This change is considered a minor change which does not affect form, fit, function, quality, or reliability.
SILICON