Si7020-A20
I2C HUMIDITY AND TEMPERATURE SENSOR
Features
Precision Relative Humidity Sensor
Factory-calibrated
± 4% RH (max), 0–80% RH
High Accuracy Temperature Sensor
±0.4 °C (max), –10 to 85 °C
0 to 100% RH operating range
Up to –40 to +125 °C operating
range
Wide operating voltage
(1.9 to 3.6 V)
Low Power Consumption
150 µA active current
60 nA standby current
I2C Interface
Integrated on-chip heater
3x3 mm DFN Package
Excellent long term stability
Optional factory-installed cover
Low-profile
Protection during reflow
Excludes liquids and particulates
Ordering Information:
See page 29.
Applications
Pin Assignments
Top View
HVAC/R
Micro-environments/data centers
Automotive climate control and
Thermostats/humidistats
Respiratory therapy
White goods
defogging
Asset and goods tracking
Mobile phones and tablets
Indoor weather stations
SDA
GND
1
2
3
6
5
4
SCL
VDD
DNC
Description
The Si7020 I2C Humidity and Temperature Sensor is a monolithic CMOS IC
integrating humidity and temperature sensor elements, an analog-to-digital
converter, signal processing, calibration data, and an I2C Interface. The patented
use of industry-standard, low-K polymeric dielectrics for sensing humidity enables
the construction of low-power, monolithic CMOS Sensor ICs with low drift and
hysteresis, and excellent long term stability.
DNC
Patent Protected. Patents pending
The humidity and temperature sensors are factory-calibrated and the calibration
data is stored in the on-chip non-volatile memory. This ensures that the sensors
are fully interchangeable, with no recalibration or software changes required.
The Si7020 is available in a 3x3 mm DFN package and is reflow solderable. It can
be used as a hardware- and software-compatible drop-in upgrade for existing RH/
temperature sensors in 3x3 mm DFN-6 packages, featuring precision sensing
over a wider range and lower power consumption. The optional factory-installed
cover offers a low profile, convenient means of protecting the sensor during
assembly (e.g., reflow soldering) and throughout the life of the product, excluding
liquids (hydrophobic/oleophobic) and particulates.
The Si7020 offers an accurate, low-power, factory-calibrated digital solution ideal
for measuring humidity, dew-point, and temperature, in applications ranging from
HVAC/R and asset tracking to industrial and consumer platforms.
Rev. 1.2 8/16
Copyright © 2016 by Silicon Laboratories
Si7020-A20
Si7020-A20
Functional Block Diagram
Vdd
Si7020
1.25V
Ref
Calibration
Memory
Humidity
Sensor
Control Logic
ADC
Temp
Sensor
SDA
SCL
I2C Interface
GND
2
Rev. 1.2
Si7020-A20
TABLE OF CONTENTS
Section
Page
1. Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2. Typical Application Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
3. Bill of Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
4. Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
4.1. Relative Humidity Sensor Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
4.2. Hysteresis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
4.3. Prolonged Exposure to High Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
4.4. PCB Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
4.5. Protecting the Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
4.6. Bake/Hydrate Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
4.7. Long Term Drift/Aging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
5. I2C Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
5.1. Issuing a Measurement Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
5.2. Reading and Writing User Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
5.3. Electronic Serial Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
5.4. Firmware Revision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
5.5. Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
6. Control Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
6.1. Register Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
7. Pin Descriptions: Si7020 (Top View) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
8. Ordering Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
9. Package Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
9.1. Package Outline: 3x3 6-pin DFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
9.2. Package Outline: 3x3 6-pin DFN with Protective Cover . . . . . . . . . . . . . . . . . . . . . .31
10. PCB Land Pattern and Solder Mask Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
11. Top Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
11.1. Si7020 Top Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
11.2. Top Marking Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
12. Additional Reference Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Document Change List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Rev. 1.2
3
Si7020-A20
1. Electrical Specifications
Unless otherwise specified, all min/max specifications apply over the recommended operating conditions.
Table 1. Recommended Operating Conditions
Symbol
VDD
TA
Test Condition
Min
1.9
Typ
—
Max
3.6
Unit
V
Parameter
Power Supply
Operating Temperature
Operating Temperature
I and Y grade
G grade
–40
–40
—
+125
+85
°C
°C
TA
—
Table 2. General Specifications
1.9 < VDD < 3.6 V; TA = –40 to 85 °C (G grade) or –40 to 125 °C (I/Y grade); default conversion time unless otherwise noted.
Parameter
Symbol
Test Condition
SCL, SDA pins
Min
0.7xVDD
—
Typ
—
Max
—
Unit
V
Input Voltage High
Input Voltage Low
Input Voltage Range
Input Leakage
V
IH
VIL
VIN
IIL
SCL, SDA pins
—
0.3xVDD
VDD
1
V
SCL, SDA pins with respect to GND
SCL, SDA pins
0.0
—
V
—
—
μA
V
Output Voltage Low
VOL
SDA pin; IOL = 2.5 mA; VDD = 3.3 V
—
—
0.6
SDA pin; IOL = 1.2 mA;
VDD = 1.9 V
—
—
0.4
V
Current
Consumption
IDD
RH conversion in progress
—
—
—
—
—
—
—
150
90
180
120
0.62
3.8
4.0
4.0
—
μA
μA
Temperature conversion in progress
2
Standby, –40 to +85 °C
0.06
μA
2
Standby, –40 to +125 °C
0.06
μA
3
Peak IDD during powerup
3.5
mA
mA
mA
2
4
Peak IDD during I C operations
3.5
5
Heater Current
I
3.1 to 94.2
HEAT
Notes:
1. Initiating a RH measurement will also automatically initiate a temperature measurement. The total conversion time will
be tCONV(RH) + tCONV(T).
2. No conversion or I2C transaction in progress. Typical values measured at 25 °C.
3. Occurs once during powerup. Duration is <5 msec.
4. Occurs during I2C commands for Reset, Read/Write User Registers, Read EID, and Read Firmware Version. Duration is
<100 µs when I2C clock speed is >100 kHz (>200 kHz for 2-byte commands).
5. Additional current consumption when HTRE bit enabled. See Section “5.5. Heater” for more information.
4
Rev. 1.2
Si7020-A20
Table 2. General Specifications (Continued)
1.9 < VDD < 3.6 V; TA = –40 to 85 °C (G grade) or –40 to 125 °C (I/Y grade); default conversion time unless otherwise noted.
Parameter
Symbol
Test Condition
12-bit RH
Min
—
—
—
—
—
—
—
—
—
Typ
10
5.8
3.7
2.6
7
Max
12
Unit
1
Conversion Time
tCONV
11-bit RH
7
10-bit RH
4.5
3.1
10.8
6.2
3.8
2.4
25
8-bit RH
ms
14-bit temperature
13-bit temperature
12-bit temperature
11-bit temperature
4
2.4
1.5
18
Powerup Time
tPU
From VDD ≥ 1.9 V to ready for a
conversion, 25 °C
From VDD ≥ 1.9 V to ready for a
conversion, full temperature range
—
—
—
5
80
15
ms
After issuing a software reset
command
Notes:
1. Initiating a RH measurement will also automatically initiate a temperature measurement. The total conversion time will
be tCONV(RH) + tCONV(T).
2. No conversion or I2C transaction in progress. Typical values measured at 25 °C.
3. Occurs once during powerup. Duration is <5 msec.
4. Occurs during I2C commands for Reset, Read/Write User Registers, Read EID, and Read Firmware Version. Duration is
<100 µs when I2C clock speed is >100 kHz (>200 kHz for 2-byte commands).
5. Additional current consumption when HTRE bit enabled. See Section “5.5. Heater” for more information.
Rev. 1.2
5
Si7020-A20
Table 3. I2C Interface Specifications1
1.9 VDD 3.6 V; TA = –40 to +85 °C (G grade) or –40 to +125 °C (I/Y grade) unless otherwise noted.
Parameter
Hysteresis
Symbol
Test Condition
Min
Typ
Max
Unit
V
High-to-low versus low-to- 0.05 x V
high transition
—
—
V
HYS
DD
2
SCLK Frequency
SCL High Time
SCL Low Time
Start Hold Time
Start Setup Time
Stop Setup Time
Bus Free Time
SDA Setup Time
SDA Hold Time
SDA Valid Time
f
—
—
—
—
—
—
—
—
—
—
—
—
—
400
—
kHz
µs
µs
µs
µs
µs
µs
ns
ns
µs
µs
ns
SCL
t
0.6
1.3
0.6
0.6
0.6
SKH
t
—
SKL
t
—
STH
t
—
STS
SPS
BUF
t
t
—
Between Stop and Start
1.3
100
100
—
—
t
—
DS
DH
t
—
t
From SCL low to data valid
From SCL low to data valid
0.9
0.9
—
VD;DAT
VD;ACK
SDA Acknowledge Valid Time
t
—
3
Suppressed Pulse Width
t
50
SPS
Notes:
1. All values are referenced to VIL and/or VIH.
2. Depending on the conversion command, the Si7020 may hold the master during the conversion (clock stretch). At
above 100 kHz SCL, the Si7020 may also hold the master briefly for user register and device ID transactions. At the
highest I2C speed of 400 kHz the stretching will be <50 µs.
3. Pulses up to and including 50 ns will be suppressed.
tSKH
tSKL
1/fSCL
tSP
SCL
SDA
tBUF
tSTH
tDS
tDH
tSPS
D6
D5
D4
D0
R/W
ACK
Start Bit
tSTS
Stop Bit
tVD
:
ACK
Figure 1. I2C Interface Timing Diagram
6
Rev. 1.2
Si7020-A20
Table 4. Humidity Sensor
1.9 ≤ VDD ≤ 3.6 V; TA = 30 °C; default conversion time unless otherwise noted.
Parameter
Symbol
Test Condition
Non-condensing
0 – 80% RH
Min
0
Typ
Max
100
±4
Unit
%RH
%RH
1
Operating Range
—
±3
2, 3
Accuracy
—
80 – 100% RH
See Figure 2.
0.025
0.05
Repeatability/Noise
12-bit resolution
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
11-bit resolution
%RH RMS
10-bit resolution
0.1
8-bit resolution
0.2
1 m/s airflow, with cover
1 m/s airflow, without cover
18
4
Response Time
τ
S
63%
17
Drift vs. Temperature
Hysteresis
0.05
%RH/°C
%RH
±1
3
Long Term Stability
< 0.25
%RH/yr
Notes:
1. Recommended humidity operating range is 20% to 80% RH (non-condensing) over –10 °C to 60 °C. Prolonged
operation beyond these ranges may result in a shift of sensor reading, with slow recovery time.
2. Excludes hysteresis, long term drift, and certain other factors and is applicable to non-condensing environments only.
See Section “4.1. Relative Humidity Sensor Accuracy” for more details.
3. Drift due to aging effects at typical room conditions of 30 °C and 30% to 50% RH. May be impacted by dust, vaporized
solvents or other contaminants, e.g., out-gassing tapes, adhesives, packaging materials, etc. See Section “4.7. Long
Term Drift/Aging” .
4. Response time to a step change in RH. Time for the RH output to change by 63% of the total RH change.
Rev. 1.2
7
Si7020-A20
Figure 2. RH Accuracy at 30 °C
8
Rev. 1.2
Si7020-A20
Table 5. Temperature Sensor
1.9 ≤ VDD ≤ 3.6 V; TA = –40 to +85 °C (G grade) or –40 to +125 °C (I/Y grade) default conversion time, unless otherwise noted.
Parameter
Symbol
Test Condition
I and Y Grade
G Grade
Min
–40
–40
—
Typ
—
Max
+125
+85
Unit
°C
Operating Range
—
°C
1
Accuracy
–10 °C< t < 85 °C
±0.3
Figure 3.
0.01
0.02
0.04
0.08
0.7
±0.4
°C
A
–40 < t < 125 °C
A
Repeatability/Noise
14-bit resolution
13-bit resolution
12-bit resolution
11-bit resolution
Unmounted device
Si7020-EB board
—
—
—
—
—
—
—
—
—
—
—
—
—
—
°C RMS
2
Response Time
τ
s
63%
5.1
s
Long Term Stability
0.01
°C/Yr
Notes:
1. 14b measurement resolution (default).
2. Time to reach 63% of final value in response to a step change in temperature. Actual response time will vary
dependent on system thermal mass and air-flow.
Rev. 1.2
9
Si7020-A20
Figure 3. Temperature Accuracy*
*Note: Applies only to I and Y grade devices beyond +85 °C.
10
Rev. 1.2
Si7020-A20
Table 6. Thermal Characteristics
Parameter
Symbol
Test Condition
DFN-6
Unit
Junction to Air Thermal Resistance
JEDEC 2-Layer board,
No Airflow
256
°C/W
JA
Junction to Air Thermal Resistance
Junction to Air Thermal Resistance
JEDEC 2-Layer board,
1 m/s Airflow
224
205
°C/W
°C/W
JA
JEDEC 2-Layer board,
2.5 m/s Airflow
JA
Junction to Case Thermal Resistance
Junction to Board Thermal Resistance
JEDEC 2-Layer board
JEDEC 2-Layer board
22
°C/W
°C/W
JC
134
JB
Table 7. Absolute Maximum Ratings1
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
Ambient temperature
under bias
–55
—
125
°C
2
Storage Temperature
Voltage on I/O pins
–65
–0.3
–0.3
—
—
—
150
°C
V
V
+0.3 V
DD
Voltage on VDD with
respect to GND
4.2
V
ESD Tolerance
HBM
CDM
MM
—
—
—
—
—
—
2
kV
kV
V
1.25
250
Notes:
1. Absolute maximum ratings are stress ratings only, operation at or beyond these conditions is not implied and may
shorten the life of the device or alter its performance.
2. Special handling considerations apply; see application note, “AN607: Si70xx Humidity Sensor Designer’s Guide”.
Rev. 1.2
11
Si7020-A20
2. Typical Application Circuits
The primary function of the Si7020 is to measure relative humidity and temperature. Figure 4 demonstrates the
typical application circuit to achieve these functions.
1.9 to 3.6V
0.1µF
10k
10k
5
VDD
6
1
SCL
SDA
SCL
SDA
Si7020
GND
2
Figure 4. Typical Application Circuit for Relative Humidity and Temperature Measurement
12
Rev. 1.2
Si7020-A20
3. Bill of Materials
Table 8. Typical Application Circuit BOM for Relative Humidity and Temperature Measurement
Reference
Description
Mfr Part Number
CR0603-16W-103JT
CR0603-16W-103JT
C0603X7R160-104M
Si7020-A20-GM
Manufacturer
Venkel
R1
R2
C1
U1
Resistor, 10 k, ±5%, 1/16 W, 0603
Resistor, 10 k, ±5%, 1/16 W, 0603
Capacitor, 0.1 µF, 16 V, X7R, 0603
IC, Digital Temperature/humidity Sensor
Venkel
Venkel
Silicon Labs
Rev. 1.2
13
Si7020-A20
4. Functional Description
Vdd
Si7020
1.25V
Ref
Calibration
Memory
Humidity
Sensor
Control Logic
ADC
Temp
Sensor
SDA
SCL
I2C Interface
GND
Figure 5. Si7020 Block Diagram
The Si7020 is a digital relative humidity and temperature sensor that integrates temperature and humidity sensor
elements, an analog-to-digital converter, signal processing, calibration, polynomial non-linearity correction, and an
2
I C interface all in a single chip. The Si7020 is individually factory-calibrated for both temperature and humidity,
with the calibration data stored in on-chip non-volatile memory. This ensures that the sensor is fully
interchangeable, with no recalibration or changes to software required. Patented use of industry-standard CMOS
and low-K dielectrics as a sensor enables the Si7020 to achieve excellent long term stability and immunity to
contaminants with low drift and hysteresis. The Si7020 offers a low-power, high-accuracy, calibrated and stable
solution ideal for a wide range of temperature, humidity, and dew-point applications including medical and
instrumentation, high-reliability automotive and industrial systems, and cost-sensitive consumer electronics.
While the Si7020 is largely a conventional mixed-signal CMOS integrated circuit, relative humidity sensors in
general and those based on capacitive sensing using polymeric dielectrics have unique application and use
requirements that are not common to conventional (non-sensor) ICs. Chief among those are:
The need to protect the sensor during board assembly, i.e., solder reflow, and the need to subsequently
rehydrate the sensor.
The need to protect the senor from damage or contamination during the product life-cycle.
The impact of prolonged exposure to extremes of temperature and/or humidity and their potential effect on
sensor accuracy.
The effects of humidity sensor “memory”.
Each of these items is discussed in more detail in the following sections.
14
Rev. 1.2
Si7020-A20
4.1. Relative Humidity Sensor Accuracy
To determine the accuracy of a relative humidity sensor, it is placed in a temperature and humidity controlled
chamber. The temperature is set to a convenient fixed value (typically 25–30 °C) and the relative humidity is swept
from 20 to 80% and back to 20% in the following steps: 20% – 40% – 60% – 80% – 80% – 60% – 40% – 20%. At
each set-point, the chamber is allowed to settle for a period of 60 minutes before a reading is taken from the
sensor. Prior to the sweep, the device is allowed to stabilize to 50%RH. The solid trace in Figure 6, “Measuring
Sensor Accuracy Including Hysteresis,” shows the result of a typical sweep.
Figure 6. Measuring Sensor Accuracy Including Hysteresis
The RH accuracy is defined as the dotted line shown in Figure 6, which is the average of the two data points at
each relative humidity set-point. In this case, the sensor shows an accuracy of 0.25%RH. The Si7020 accuracy
specification (Table 4) includes:
Unit-to-unit and lot-to-lot variation
Accuracy of factory calibration
Margin for shifts that can occur during solder reflow
The accuracy specification does not include:
Hysteresis (typically ±1%)
Effects from long term exposure to very humid conditions
Contamination of the sensor by particulates, chemicals, etc.
Other aging related shifts ("Long-term stability")
Variations due to temperature (see Drift vs. Temperature in Table 4). RH readings will typically vary with
temperature by less than 0.05% C.
Rev. 1.2
15
Si7020-A20
4.2. Hysteresis
The moisture absorbent film (polymeric dielectric) of the humidity sensor will carry a memory of its exposure
history, particularly its recent or extreme exposure history. A sensor exposed to relatively low humidity will carry a
negative offset relative to the factory calibration, and a sensor exposed to relatively high humidity will carry a
positive offset relative to the factory calibration. This factor causes a hysteresis effect illustrated by the solid trace
in Figure 6. The hysteresis value is the difference in %RH between the maximum absolute error on the decreasing
humidity ramp and the maximum absolute error on the increasing humidity ramp at a single relative humidity
setpoint and is expressed as a bipolar quantity relative to the average error (dashed trace). In the example of
Figure 6, the measurement uncertainty due to the hysteresis effect is ±1.0%RH.
4.3. Prolonged Exposure to High Humidity
Prolonged exposure to high humidity will result in a gradual upward drift of the RH reading. The shift in sensor
reading resulting from this drift will generally disappear slowly under normal ambient conditions. The amount of
shift is proportional to the magnitude of relative humidity and the length of exposure. In the case of lengthy
exposure to high humidity, some of the resulting shift may persist indefinitely under typical conditions. It is generally
possible to substantially reverse this affect by baking the device (see Section “4.6. Bake/Hydrate Procedure” ).
4.4. PCB Assembly
4.4.1. Soldering
Like most ICs, Si7020 devices are shipped from the factory vacuum-packed with an enclosed desiccant to avoid
any RH accuracy drift during storage and to prevent any moisture-related issues during solder reflow. The following
guidelines should be observed during PCB assembly:
Si7020 devices are compatible with standard board assembly processes. Devices should be soldered
using reflow per the recommended card reflow profile. See Section “10. PCB Land Pattern and Solder
Mask Design” for the recommended card reflow profile.
A "no clean" solder process is recommended to minimize the need for water or solvent rinses after
soldering. Cleaning after soldering is possible, but must be done carefully to avoid impacting the
performance of the sensor. See “AN607: Si70xx Humidity Sensor Designer’s Guide” for more information
on cleaning.
It is essential that the exposed polymer sensing film be kept clean and undamaged. This can be
accomplished by careful handling and a clean, well-controlled assembly process. When in doubt or for
extra protection, a heat-resistant, protective cover such as Kapton™ KPPD-1/8 polyimide tape can be
installed during PCB assembly.
Si7020s may be ordered with a factory-fitted, solder-resistant protective cover. This cover provides protection
during PCB assembly or rework but without the time and effort required to install and remove the Kapton tape. It
can be left in place for the lifetime of the product, preventing liquids, dust or other contaminants from coming into
contact with the polymer sensor film. See Section “8. Ordering Guide” for a list of ordering part numbers that
include the cover.
4.4.2. Rehydration
The measured humidity value will generally shift slightly after solder reflow. A portion of this shift is permanent and
is accounted for in the accuracy specifications in Table 4. After soldering, an Si7020 should be allowed to
equilibrate under controlled RH conditions (room temperature, 45–55%RH) for at least 48 hours to eliminate the
remainder of the shift and return the device to its specified accuracy performance.
16
Rev. 1.2
Si7020-A20
4.4.3. Rework
To maintain the specified sensor performance, care must be taken during rework to minimize the exposure of the
device to excessive heat and to avoid damage/contamination or a shift in the sensor reading due to liquids, solder
flux, etc. Manual touch-up using a soldering iron is permissible under the following guidelines:
The exposed polymer sensing film must be kept clean and undamaged. A protective cover is
recommended during any rework operation (Kapton® tape or the factory installed cover).
Flux must not be allowed to contaminate the sensor; liquid flux is not recommended even with a cover in
place. Conventional lead-free solder with rosin core is acceptable for touch-up as long as a cover is in
place during the rework.
If possible, avoid water or solvent rinses after touch-up. Cleaning after soldering is possible, but must be
done carefully to avoid impacting the performance of the sensor. See “AN607: Si70xx Humidity Sensor
Designer’s Guide” for more information on cleaning.
Minimize the heating of the device. Soldering iron temperatures should not exceed 350 °C and the contact
time per pin should not exceed five seconds.
Hot air rework is not recommended. If a device must be replaced, remove the device by hot air and solder
a new part in its place by reflow following the guidelines above.
*Note: All trademarks are the property of their respective owners.
Figure 7. Si7020 with Factory-Installed Protective Cover
Rev. 1.2
17
Si7020-A20
4.5. Protecting the Sensor
Because the sensor operates on the principal of measuring a change in capacitance, any changes to the dielectric
constant of the polymer film will be detected as a change in relative humidity. Therefore, it is important to minimize
the probability of contaminants coming into contact with the sensor. Dust and other particles as well as liquids can
affect the RH reading. It is recommended that a cover is employed in the end system that blocks contaminants but
allows water vapor to pass through. Depending on the needs of the application, this can be as simple as plastic or
metallic gauze for basic protection against particulates or something more sophisticated such as a hydrophobic
membrane providing up to IP67 compliant protection.
The Si7020 may be ordered with a factory-fitted, solder-resistant cover that can be left in place for the lifetime of
the product. It is very low-profile, hydrophobic and oleophobic. See Section “8. Ordering Guide” for a list of
ordering part numbers that include the cover. A dimensioned drawing of the IC with the cover is included in Section
“9. Package Outline” . Other characteristics of the cover are listed in Table 9.
Table 9. Specifications of Protective Cover
Parameter
Value
PTFE
Material
Operating Temperature
–40 to 125 °C
260 °C
Maximum Reflow Temperature
IP Rating (per IEC 529)
IP67
4.6. Bake/Hydrate Procedure
After exposure to extremes of temperature and/or humidity for prolonged periods, the polymer sensor film can
become either very dry or very wet, in each case the result is either high or low relative humidity readings. Under
normal operating conditions, the induced error will diminish over time. From a very dry condition, such as after
shipment and soldering, the error will diminish over a few days at typical controlled ambient conditions, e.g.,
48 hours of 45 ≤ %RH ≤ 55. However, from a very wet condition, recovery may take significantly longer. To
accelerate recovery from a wet condition, a bake and hydrate cycle can be implemented. This operation consists of
the following steps:
Baking the sensor at 125 °C for ≥ 12 hours
Hydration at 30 °C in 75% RH for ≥ 10 hours
Following this cycle, the sensor will return to normal operation in typical ambient conditions after a few days.
4.7. Long Term Drift/Aging
Over long periods of time, the sensor readings may drift due to aging of the device. Standard accelerated life
testing of the Si7020 has resulted in the specifications for long-term drift shown in Table 4 and Table 5. This
contribution to the overall sensor accuracy accounts only for the long-term aging of the device in an otherwise
benign operating environment and does not include the effects of damage, contamination, or exposure to extreme
environmental conditions.
18
Rev. 1.2
Si7020-A20
5. I2C Interface
2
The Si7020 communicates with the host controller over a digital I C interface. The 7-bit base slave address is
0x40.
2
Table 10. I C Slave Address Byte
A6
A5
A4
A3
A2
A1
A0
R/W
1
0
0
0
0
0
0
0
2
2
Master I C devices communicate with the Si7020 using a command structure. The commands are listed in the I C
command table. Commands other than those documented below are undefined and should not be sent to the
device.
Table 11. I2C Command Table
Command Description
Measure Relative Humidity, Hold Master Mode
Command Code
0xE5
Measure Relative Humidity, No Hold Master Mode
Measure Temperature, Hold Master Mode
Measure Temperature, No Hold Master Mode
Read Temperature Value from Previous RH Measurement
Reset
0xF5
0xE3
0xF3
0xE0
0xFE
Write RH/T User Register 1
0xE6
Read RH/T User Register 1
0xE7
Write Heater Control Register
0x51
Read Heater Control Register
0x11
Read Electronic ID 1st Byte
0xFA 0x0F
0xFC 0xC9
0x84 0xB8
Read Electronic ID 2nd Byte
Read Firmware Revision
Rev. 1.2
19
Si7020-A20
5.1. Issuing a Measurement Command
The measurement commands instruct the Si7020 to perform one of two possible measurements; Relative Humidity
or Temperature. The procedure to issue any one of these commands is identical. While the measurement is in
progress, the option of either clock stretching (Hold Master Mode) or Not Acknowledging read requests (No Hold
Master Mode) is available to indicate to the master that the measurement is in progress; the chosen command
code determines which mode is used.
Optionally, a checksum byte can be returned from the slave for use in checking for transmission errors. The
checksum byte will follow the least significant measurement byte if it is acknowledged by the master. The
checksum byte is not returned if the master “not acknowledges” the least significant measurement byte. The
8
5
4
checksum byte is calculated using a CRC generator polynomial of x + x + x + 1, with an initialization of 0x00.
The checksum byte is optional after initiating an RH or temperature measurement with commands 0xE5, 0xF5,
0xE3, and 0xF3. The checksum byte is required for reading the electronic ID with commands 0xFA 0x0F and 0xFC
0xC9. For all other commands, the checksum byte is not supported.
Table 12. I2C Bit Descriptions
Name
Symbol
Description
START
S
P
SDA goes low while SCL high.
SDA goes high while SCL high.
STOP
Repeated START
Sr
SDA goes low while SCL high. It is allowable to generate a STOP before the
repeated start. SDA can transition to high before or after SCL goes high in
preparation for generating the START.
READ
R
W
—
Read bit = 1
Write bit = 0
WRITE
All other bits
SDA value must remain high or low during the entire time SCL is high (this is
the set up and hold time in Figure 1).
2
In the I C sequence diagrams in the following sections, bits produced by the master and slave are color coded as
shown:
Master
Slave
20
Rev. 1.2
Si7020-A20
Sequenceꢀtoꢀperformꢀaꢀmeasurementꢀandꢀreadꢀbackꢀresultꢀ(HoldꢀMasterꢀMode)ꢀ
Clockꢀstretchꢀ
duringꢀ
measurementꢀ
Slaveꢀ
Addressꢀ
Measureꢀ
Cmdꢀ
Slaveꢀ
Addressꢀ
Sꢀ
Wꢀ Aꢀ
Aꢀ Srꢀ
Rꢀ Aꢀ
ꢀꢀ
ꢀꢀ
MSꢀByteꢀ
Aꢀ
LSꢀByteꢀ
NAꢀ Pꢀ
Aꢀ Checksumꢀ NA Pꢀ
Note: Device will NACK the slave address byte until conversion is complete.
Rev. 1.2
21
Si7020-A20
5.1.1. Measuring Relative Humidity
Once a relative humidity measurement has been made, the results of the measurement may be converted to
percent relative humidity by using the following expression:
125 RH_Code
%RH = --------------------------------------- – 6
65536
Where:
%RH is the measured relative humidity value in %RH
RH_Code is the 16-bit word returned by the Si7020
A humidity measurement will always return XXXXXX10 in the LSB field.
Due to normal variations in RH accuracy of the device as described in Table 4, it is possible for the measured value
of %RH to be slightly less than 0 when the actual RH level is close to or equal to 0. Similarly, the measured value
of %RH may be slightly greater than 100 when the actual RH level is close to or equal to 100. This is expected
behavior, and it is acceptable to limit the range of RH results to 0 to 100%RH in the host software by truncating
values that are slightly outside of this range.
5.1.2. Measuring Temperature
Each time a relative humidity measurement is made a temperature measurement is also made for the purposes of
temperature compensation of the relative humidity measurement. If the temperature value is required, it can be
read using command 0xE0; this avoids having to perform a second temperature measurement. The measure
temperature commands 0xE3 and 0xF3 will perform a temperature measurement and return the measurement
value, command 0xE0 does not perform a measurement but returns the temperature value measured during the
relative humidity measurement.
The checksum output is not available with the 0xE0 command.
SequenceꢀtoꢀreadꢀtemperatureꢀvalueꢀfromꢀpreviousꢀRHꢀmeasurementꢀ
Slaveꢀ
Addressꢀ
Slaveꢀ
Addressꢀ
Sꢀ
Wꢀ Aꢀ
0xE0ꢀ
Aꢀ Srꢀ
Rꢀ Aꢀ
MSꢀByteꢀ
ꢀ
Aꢀ
LSꢀByteꢀ
NAꢀ Pꢀ
22
Rev. 1.2
Si7020-A20
The results of the temperature measurement may be converted to temperature in degrees Celsius (°C) using the
following expression:
175.72 Temp_Code
Temperature (C = ------------------------------------------------------- – 46.85
65536
Where:
Temperature (°C) is the measured temperature value in °C
Temp_Code is the 16-bit word returned by the Si7020
A temperature measurement will always return XXXXXX00 in the LSB field.
Rev. 1.2
23
Si7020-A20
5.2. Reading and Writing User Registers
There is one user register on the Si7020 that allows the user to set the configuration of the Si7020. The procedure
for accessing that register is described below.
The checksum byte is not supported after reading a user register.
Sequence to read a register
Slave
Read Reg
Cmd
Slave
S
W
A
A
Sr
R
A
Read Data
NA
P
Address
Address
Sequence to write a register
Write Reg Cmd
S
Slave Address
W
A
A
Write Data
A
P
5.3. Electronic Serial Number
2
The Si7020 provides a serial number individualized for each device that can be read via the I C serial interface.
2
Two I C commands are required to access the device memory and retrieve the complete serial number. The
command sequence, and format of the serial number response is described in the figure below:
Master
Slave
First access:
S
S
Slave Address
Slave Address
SNA_3
W
R
ACK
ACK
CRC
CRC
0xFA
ACK
0X0F
ACK
ACK
ACK
ACK
ACK
SNA_2
SNA_0
ACK
ACK
CRC
CRC
ACK
SNA_1
NACK
P
2nd access:
S
S
Slave Address
Slave Address
SNB_3
W
R
ACK
ACK
0xFC
ACK
0XC9
ACK
P
ACK
ACK
SNB_2
SNB_0
ACK
ACK
CRC
CRC
ACK
SNB_1
NACK
The format of the complete serial number is 64-bits in length, divided into 8 data bytes. The complete serial number
sequence is shown below:
SNA_3
SNA_2
SNA_1
SNA_0
SNB_3
SNB_2
SNB_1
SNB_0
The SNB3 field contains the device identification to distinguish between the different Silicon Labs relative humidity
and temperature devices. The value of this field maps to the following devices according to this table:
24
Rev. 1.2
Si7020-A20
0x00 or 0xFF engineering samples
0x0D=13=Si7013
0x14=20=Si7020
0x15=21=Si7021
5.4. Firmware Revision
2
The internal firmware revision can be read with the following I C transaction:
Slave
Slave
S
W
A
0x84
A
0xB8
A
S
Address
Address
R
A
FWREV
NA
P
The values in this field are encoded as follows:
0xFF = Firmware version 1.0
0x20 = Firmware version 2.0
5.5. Heater
The Si7020 contains an integrated resistive heating element that may be used to raise the temperature of the
sensor. This element can be used to test the sensor, to drive off condensation, or to implement dew-point
measurement when the Si7020 is used in conjunction with a separate temperature sensor such as another Si7020
(the heater will raise the temperature of the internal temperature sensor).
The heater can be activated using HTRE, bit 2 in User Register 1. Turning on the heater will reduce the tendency
of the humidity sensor to accumulate an offset due to "memory" of sustained high humidity conditions. Several
different power levels are available. The various settings are adjusted using the Heater Control Register and are
described in the following table.
Table 13. Heater Control Settings
*
HEATER[3:0]
Typical Current Draw (mA)
0000
0001
0010
...
3.09
9.18
15.24
...
0100
...
27.39
...
1000
...
51.69
...
1111
94.20
*Note: Assumes VDD = 3.3 V.
Rev. 1.2
25
Si7020-A20
6. Control Registers
Table 14. Register Summary
Register
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
User Register 1
RES1
VDDS
RSVD
RSVD
RSVD
HTRE
RSVD
RES0
Heater Control
Register
RSVD
HEATER[3:0]
Notes:
1. Any register not listed here is reserved and must not be written. The result of a read operation on these bits is
undefined.
2. Except where noted, reserved register bits will always read back as “1,” and are not affected by write operations. For
future compatibility, it is recommended that prior to a write operation, registers should be read. Then the values read
from the RSVD bits should be written back unchanged during the write operation.
6.1. Register Descriptions
Register 1. User Register 1
Bit
D7
D6
VDDS
R
D5
D4
D3
D2
D1
D0
Name
Type
RES1
R/W
RSVD
R/W
RSVD
RSVD
HTRE
R/W
RSVD
R/W
RES0
R/W
R/W
Reset Settings = 0011_1010
Bit
Name
Function
D7; D0
RES[1:0]
Measurement Resolution:
RH
Temp
14 bit
12 bit
13 bit
11 bit
00:
01:
10:
11:
12 bit
8 bit
10 bit
11 bit
D6
VDDS
V
Status:
DD
0:
1:
V
V
OK
Low
DD
DD
The minimum recommended operating voltage is 1.9 V. A transi-
tion of the V status bit from 0 to 1 indicates that V is
DD
DD
between 1.8 V and 1.9 V. If the V drops below 1.8 V, the
DD
device will no longer operate correctly.
D5, D4, D3
D2
RSVD
HTRE
Reserved
1 = On-chip Heater Enable
0 = On-chip Heater Disable
D1
RSVD
Reserved
26
Rev. 1.2
Si7020-A20
Register 2. Heater Control Register
Bit
D7
D6
D5
D4
D3
D2
Heater [3:0]
R/W
D1
D0
Name
Type
RSVD
R/W
Reset Settings = 0000_0000
Bit
Name
Function
D3:D0 HEATER[3:0]
D3
0
D2
D1
0
D0
0
Heater Current
0
0
0
3.09 mA
9.18 mA
15.24 mA
0
0
1
0
1
0
...
0
0
1
1
0
1
0
0
1
27.39 mA
...
0
51.69 mA
94.20 mA
...
1
1
D7,D6,
D5,D4
RSVD
Reserved
Rev. 1.2
27
Si7020-A20
7. Pin Descriptions: Si7020 (Top View)
SDA
GND
1
2
3
6
5
4
SCL
VDD
DNC
DNC
Pin Name
SDA
Pin #
Pin Description
2
1
2
I C data
GND
Ground. This pin is connected to ground on the circuit board through a trace. Do not
connect directly to GND plane.
VDD
SCL
DNC
5
6
Power. This pin is connected to power on the circuit board.
2
I C clock
3,4
These pins should be soldered to pads on the PCB for mechanical stability; they can be
electrically floating or tied to V (do not tie to GND).
DD
T
Paddle This pad is connected to GND internally. This pad is the main thermal input to the
GND
on-chip temperature sensor. The paddle should be soldered to a floating pad.
28
Rev. 1.2
Si7020-A20
8. Ordering Guide
Table 15. Device Ordering Guide
P/N
Description
Max.
Pkg
Operating
Protective Packing
Accuracy
Range (°C)
Cover
Format
Temp
RH
Si7020-A20-GM Digital temperature/ humidity sensor
Si7020-A20-GMR Digital temperature/ humidity sensor
Si7020-A20-GM1 Digital temperature/ humidity sensor
Si7020-A20-GM1R Digital temperature/ humidity sensor
±0.4 °C ± 4% DFN 6
±0.4 °C ± 4% DFN 6
±0.4 °C ± 4% DFN 6
±0.4 °C ± 4% DFN 6
–40 to +85 °C
–40 to +85 °C
–40 to +85 °C
–40 to +85 °C
N
N
Y
Y
N
N
Y
Y
N
N
Y
Y
Cut
Tape
Tape &
Reel
Cut
Tape
Tape &
Reel
Si7020-A20-IM
Digital temperature/ humidity sensor – ±0.4 °C ± 4% DFN 6 –40 to +125 °C
industrial temp range
Cut
Tape
Si7020-A20-IMR Digital temperature/ humidity sensor – ±0.4 °C ± 4% DFN 6 –40 to +125 °C
industrial temp range
Tape &
Reel
Si7020-A20-IM1 Digital temperature/ humidity sensor – ±0.4 °C ± 4% DFN 6 –40 to +125 °C
industrial temp range
Cut
Tape
Si7020-A20-IM1R Digital temperature/ humidity sensor – ±0.4 °C ± 4% DFN 6 –40 to +125 °C
industrial temp range
Tape &
Reel
Si7020-A20-YM0 Digital temperature/ humidity sensor – ±0.4 °C ± 4% DFN 6 –40 to +125 °C
automotive
Cut
Tape
Si7020-A20-YM0R Digital temperature/ humidity sensor – ±0.4 °C ± 4% DFN 6 –40 to +125 °C
automotive
Tape &
Reel
Si7020-A20-YM1 Digital temperature/ humidity sensor – ±0.4 °C ± 4% DFN 6 –40 to +125 °C
automotive
Cut
Tape
Si7020-A20-YM1R Digital temperature/ humidity sensor – ±0.4 °C ± 4% DFN 6 –40 to +125 °C
automotive
Tape &
Reel
Note: The “A” denotes product revision A and “20” denotes firmware version 2.0.
Rev. 1.2
29
Si7020-A20
9. Package Outline
9.1. Package Outline: 3x3 6-pin DFN
Figure 10. 3x3 6-pin DFN
Table 16. 3x3 6-pin DFN Package Diagram Dimensions
Dimension
Min
Nom
Max
A
A1
b
0.70
0.00
0.35
0.75
0.02
0.80
0.05
0.45
0.40
D
3.00 BSC.
1.50
D2
e
1.40
1.60
1.00 BSC.
3.00 BSC.
2.40
E
E2
H1
H2
L
2.30
0.85
1.39
0.35
2.50
0.95
1.49
0.45
0.90
1.44
0.40
aaa
bbb
ccc
ddd
eee
fff
0.10
0.10
0.05
0.10
0.05
0.05
Notes:
1. All dimensions shown are in millimeters (mm).
2. Dimensioning and Tolerancing per ANSI Y14.5M-1994.
30
Rev. 1.2
Si7020-A20
9.2. Package Outline: 3x3 6-pin DFN with Protective Cover
Figure 8 illustrates the package details for the Si7020 with the optional protective cover. The table below lists the
values for the dimensions shown in the illustration.
Figure 8. 3x3 6-pin DFN with Protective Cover
Table 17. 3x3 6-pin DFN with Protective Cover Package Diagram Dimensions
Dimension
Min
—
Nom
—
Max
1.21
0.05
0.80
0.45
A
A1
A2
b
0.00
0.70
0.35
0.02
0.75
0.40
D
3.00 BSC.
1.50
D2
e
1.40
1.60
1.00 BSC.
3.00 BSC.
2.40
E
E2
F1
F2
h
2.30
2.70
2.70
0.76
0.35
0.45
2.50
2.90
2.90
0.90
0.45
0.55
2.80
2.80
0.83
L
0.40
R1
aaa
bbb
ccc
ddd
eee
0.50
0.10
0.10
0.05
0.10
0.05
Notes:
1. All dimensions are shown in millimeters (mm).
2. Dimensioning and Tolerancing per ANSI Y14.5M-1994.
Rev. 1.2
31
Si7020-A20
10. PCB Land Pattern and Solder Mask Design
Figure 9. Si7020 PCB Land Pattern
Table 18. PCB Land Pattern Dimensions
Symbol
C1
mm
2.90
1.00
1.60
2.50
0.45
0.85
E
P1
P2
X1
Y1
Notes:
General
1. All dimensions shown are at Maximum Material Condition (MMC). Least Material
Condition (LMC) is calculated based on a Fabrication Allowance of 0.05 mm.
2. This Land Pattern Design is based on the IPC-7351 guidelines.
Solder Mask Design
3. All metal pads are to be non-solder mask defined (NSMD). Clearance between the
solder mask and the metal pad is to be 60 µm minimum, all the way around the
pad.
Stencil Design
4. A stainless steel, laser-cut and electro-polished stencil with trapezoidal walls
should be used to assure good solder paste release.
5. The stencil thickness should be 0.125 mm (5 mils).
6. The ratio of stencil aperture to land pad size should be 1:1 for all perimeter pins.
7. A 2x1 array of 1.00 mm square openings on 1.30 mm pitch should be used for the
center ground pad to achieve a target solder coverage of 50%.
Card Assembly
8. The recommended card reflow profile is per the JEDEC/IPC J-STD-020
specification for Small Body Components.
32
Rev. 1.2
Si7020-A20
11. Top Marking
11.1. Si7020 Top Marking
11.2. Top Marking Explanation
Mark Method:
Font Size
Laser
0.30 mm
Pin 1 Indicator:
Line 1 Marking:
Circle = 0.30 mm Diameter
Upper-Left Corner
TTTT = Mfg Code
Rev. 1.2
33
Si7020-A20
12. Additional Reference Resources
AN607: Si70xx Humidity Sensor Designer’s Guide
34
Rev. 1.2
Si7020-A20
DOCUMENT CHANGE LIST
Revision 0.9 to Revision 0.91
Updated Table 2 on page 4.
Revision 0.91 to Revision 1.0
Updated document revision to 1.0.
Revision 1.0 to Revision 1.1
Updated note 2 in Table 3.
Updated Section 4.5.
Updated Table 9.
2
Corrected a typo in the I C sequence for no-hold
mode in Section 5.1.
Corrected a typo in Table 12.
Updated Table 17, dimensions F1 and F2.
Revision 1.1 to Revision 1.2
Updated diagram in "5.4. Firmware Revision" on
page 25.
Updated notes in Table 18, “PCB Land Pattern
Dimensions,” on page 32.
Changed packing format from tube to cut tape for all
non-tape & reel part numbers without protective filter
covers.
Rev. 1.2
35
Smart.
Connected.
Energy-Friendly
Products
www.silabs.com/products
Quality
www.silabs.com/quality
Support and Community
community.silabs.com
Disclaimer
Silicon Laboratories intends to provide customers with the latest, accurate, and in-depth documentation of all peripherals and modules available for system and software implementers
using or intending to use the Silicon Laboratories products. Characterization data, available modules and peripherals, memory sizes and memory addresses refer to each specific
device, and "Typical" parameters provided can and do vary in different applications. Application examples described herein are for illustrative purposes only. Silicon Laboratories
reserves the right to make changes without further notice and limitation to product information, specifications, and descriptions herein, and does not give warranties as to the accuracy
or completeness of the included information. Silicon Laboratories shall have no liability for the consequences of use of the information supplied herein. This document does not imply
or express copyright licenses granted hereunder to design or fabricate any integrated circuits. The products must not be used within any Life Support System without the specific
written consent of Silicon Laboratories. A "Life Support System" is any product or system intended to support or sustain life and/or health, which, if it fails, can be reasonably expected
to result in significant personal injury or death. Silicon Laboratories products are generally not intended for military applications. Silicon Laboratories products shall under no
circumstances be used in weapons of mass destruction including (but not limited to) nuclear, biological or chemical weapons, or missiles capable of delivering such weapons.
Trademark Information
Silicon Laboratories Inc., Silicon Laboratories, Silicon Labs, SiLabs and the Silicon Labs logo, CMEMS®, EFM, EFM32, EFR, Energy Micro, Energy Micro logo and combinations
thereof, "the world’s most energy friendly microcontrollers", Ember®, EZLink®, EZMac®, EZRadio®, EZRadioPRO®, DSPLL®, ISOmodem ®, Precision32®, ProSLIC®, SiPHY®,
USBXpress® and others are trademarks or registered trademarks of Silicon Laboratories Inc. ARM, CORTEX, Cortex-M3 and THUMB are trademarks or registered trademarks of
ARM Holdings. Keil is a registered trademark of ARM Limited. All other products or brand names mentioned herein are trademarks of their respective holders.
Silicon Laboratories Inc.
400 West Cesar Chavez
Austin, TX 78701
USA
http://www.silabs.com
相关型号:
Si7021-A10-GM
This change is considered a minor change which does not affect form, fit, function, quality, or reliability.