SI8503-B-GM 概述
UNIDIRECTIONAL AC CURRENT SENSORS 单向交流电流传感器 其他模拟IC
SI8503-B-GM 规格参数
是否无铅: | 不含铅 | 是否Rohs认证: | 符合 |
生命周期: | Obsolete | 零件包装代码: | QFN |
包装说明: | VQCCN, | 针数: | 12 |
Reach Compliance Code: | unknown | HTS代码: | 8542.39.00.01 |
风险等级: | 5.83 | 模拟集成电路 - 其他类型: | ANALOG CIRCUIT |
JESD-30 代码: | S-XBCC-N12 | 长度: | 4 mm |
湿度敏感等级: | 2 | 功能数量: | 1 |
端子数量: | 12 | 最高工作温度: | 85 °C |
最低工作温度: | -40 °C | 封装主体材料: | UNSPECIFIED |
封装代码: | VQCCN | 封装形状: | SQUARE |
封装形式: | CHIP CARRIER, VERY THIN PROFILE | 峰值回流温度(摄氏度): | 260 |
认证状态: | Not Qualified | 座面最大高度: | 0.9 mm |
最大供电电压 (Vsup): | 5.5 V | 最小供电电压 (Vsup): | 2.7 V |
表面贴装: | YES | 温度等级: | INDUSTRIAL |
端子形式: | NO LEAD | 端子节距: | 0.5 mm |
端子位置: | BOTTOM | 处于峰值回流温度下的最长时间: | 40 |
宽度: | 4 mm | Base Number Matches: | 1 |
SI8503-B-GM 数据手册
通过下载SI8503-B-GM数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Si85xx
Si85XX UNIDIRECTIONAL AC CURRENT SENSORS
Features
Pin Assignments:
See page 20
Single-chip ac current
FAULT output helps safeguard
sensor/conditioner
operation
Low loss: Less than 1.3 mΩ
primary series resistance;
less than 2 nH primary
inductance at 25 ºC
1,000 VDC isolation
Accurate to ±5% of measurement
12-Pin QFN
Large 2 V output pins signal at
PP
full scale
Leading-edge noise suppression
eliminates need for leading-edge
blanking
High-side or low-side current
sensing
R1
IIN
R2
GND2
GND3
–40 to 125 ºC operating range
"Ping-Pong" output version
allows one Si85xx to replace two
current transformers in full-bridge
applications
(Si85x4/5/6)
Si850x
Small 4 x 4 x 1 mm package
Low cost
OUT
NC
IOUT
5, 10, and 20 A full-scale versions
Applications
Power supplies
Motor controls
Lighting equipment
Industrial equipment
R1
IIN
Description
R2
R3
R4
The Si85xx products are unidirectional ac current sensors available in full-
scale ranges of 5, 10, and 20 A. Si85xx products are ideal upgrades for
older current-sensing technologies offering size, performance and cost
advantages over current transformers, Hall effect devices, DCR circuits
and other approaches. The Si85xx are extremely low loss, adding less
than 1.3 mΩ of series resistance and less than 2 nH series inductance in
the sensing path at 25 ºC. Current-sensing terminals are isolated from the
other package pins to a maximum voltage of 1,000 VDC.
Si851x
OUT1
IOUT
OUT2
Functional Block Diagram
Patents pending
R1
R2
R3
R4
IIN
VDD
Si851x
VIN
IIN
MODE
VDD1 TRST
R2
RESET LOGIC
MODE LOGIC
Si850x
GND1
OUT
GND2
OUT1
OUT2
INTEGRATOR
SIGNAL CONDITIONING
R1
IOUT
Q1
L
PH1
VOUT
C
Q2
PH2
AUTO CALIBRATION
LOGIC
TEMP
SENSOR
ADC
Typical Application
IOUT
GND
TRST/FAULT
VDD
Preliminary Rev. 0.1 7/07
Copyright © 2007 by Silicon Laboratories
Si85xx
This information applies to a product under development. Its characteristics and specifications are subject to change without notice.
Silicon Laboratories Confidential. Information contained herein is covered under non-disclosure agreement (NDA).
Si85xx
2
Preliminary Rev. 0.1
Si85xx
TABLE OF CONTENTS
Section
Page
1. Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2. Functional Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
2.1. Under Voltage Lockout (UVLO) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.2. Device Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.3. Integrator Reset and Current Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.4. Effect of Operating Frequency on Output Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . .8
2.5. Effect of Temperature on Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
2.6. Leading Edge Noise Suppression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
2.7. FAULT Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
3. Application Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
3.1. Board Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
3.2. Device Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
3.3. Single-Phase Buck Converter Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
3.4. Full-Bridge Converter Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
3.5. Push-Pull Converter Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
4. Pin Descriptions—Si85xx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
5. Ordering Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
6. Package Outline—12-Pin QFN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Preliminary Rev. 0.1
3
Si85xx
1. Electrical Specifications
Table 1. Electrical Specifications
TA = –40 to +85 ºC (typical specified at 25 ºC), VDD = 2.7 to 5.5 V
Parameter
Conditions
Min
2.7
—
Typ
—
4
Max
5.5
7
Unit
V
Supply Voltage (V
)
DD
Supply Current
Fully enabled, input frequency =
1 MHz
mA
Undervoltage Lockout (V
)
2.1
—
2.3
2.5
—
V
UVLO
Undervoltage Lockout Hysteresis
(V
100
mV
)
HYST
Logic Input HIGH Level
Logic Input LOW Level
MODE, R1, R2, R3, R4 inputs
(TTL compatible)
2.0
—
—
—
—
—
—
50
1.3
2
—
0.8
—
V
V
Reset Time (t )
250
—
ns
ns
ns
µs
mΩ
nH
ns
R
R1, R2, R3, R4 Input Rise Time (t
)
30
30
80
—
RR
R1, R2, R3, R4 Input Fall Time (t
)
—
FR
Measurement Watchdog Timeout (t
Series Input Resistance
Series Inductance
)
30
—
WD
Measured from IIN to IOUT
Measured from IIN to IOUT
—
—
Input/Output Delay
OUT, OUT1, OUT2 delay relative to
input
—
50
100
Start-Up Self-Cal Delay (t
)
Time from VDD = V
+ V to
HYST
—
150
200
µs
CAL
UVLO
cal complete
Input Common Mode Voltage Range
Operating Input Frequency Range (f)
DC Power Supply Rejection Ratio
Sensitivity
—
50
—
—
—
—
—
—
—
1,000
1,200
—
V
kHz
db
80
Si85x1/4/7
Si85x2/5/8
Si85x3/6/9
400
200
100
10
—
mV/A
mV/A
mV/A
mV
—
—
OUT, OUT1, OUT2 Offset Voltage
Current flow from I to I
= 0
—
IN
OUT
(V
)
OUTMIN
VOUT Slew Rate
OUT, OUT1, OUT2 load = 5K || 50 pF
—
20
50
—
30
V/µs
Ω
OUT, OUT1, OUT2 Output Resistance
Measurement Error (%)—all devices
(–40 to 85 ºC Temp Range)
5 to 10% of full scale
10 to 20% of full scale
20 to 100% of full scale
–20
–10
–5
—
—
—
+20
+10
+5
%
%
%
4
Preliminary Rev. 0.1
Si85xx
Table 1. Electrical Specifications (Continued)
TA = –40 to +85 ºC (typical specified at 25 ºC), VDD = 2.7 to 5.5 V
Parameter
Conditions
Min
–30
–25
–20
Typ
—
Max
+30
+25
+20
Unit
%
Measurement Error (%)—all devices
(–40 to 125 ºC Temp Range)
5 to 10% of full scale
10 to 20% of full scale
20 to 100% of full scale
—
%
—
%
Table 2. Absolute Maximum Ratings
Parameter
Storage temperature
Symbol
Min
–65
–40
Typ
Max
Units
ºC
ºC
V
T
+150
+125
5.75
STG
Ambient temperature under bias
Supply voltage
T
A
V
DD
Voltage on any pin with respect to ground
(not including IIN, IOUT)
V
–0.5
VDD + 0.5
V
IN
Lead solder temperature (10 sec.)
DC isolation
-
260
ºC
-
1000
VDC
Note: Permanent device damage may occur if the above Absolute Maximum Ratings are exceeded. Functional operation
should be restricted to conditions as specified in the operational sections of this data sheet. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
Preliminary Rev. 0.1
5
Si85xx
2. Functional Overview
The Si85xx AC Current Sensor family of products mimic
the functionality of a traditional current transformer (CT)
circuit with burden resistor, diode and output filter, but
offers enhanced performance and added capabilities.
These devices use inductive current sensing and on-
board signal conditioning electronics to generate a 2 V
full-scale output signal proportional to the ac current
flowing from the IIN to the IOUT terminals. As shown in
Figure 1 and Figure 2, current flowing through the metal
package slug induces a signal in the pickup coil on-
board the Si85xx die. This signal is applied to the input
of an integrator that re-constructs the ac current flowing
from IIN to IOUT. On-board circuitry provides cycle-by-
cycle integrator reset, and temperature and offset
voltage compensation to achieve measurement
accuracy to within ±5%.
R1
R2
R3
R4
IIN
Si851x
MODE
RESET LOGIC
MODE LOGIC
OUT1
OUT2
INTEGRATOR
SIGNAL CONDITIONING
PICKUP
COIL
AUTO CALIBRATION
LOGIC
TEMP
SENSOR
ADC
IOUT
GND
TRST/FAULT
VDD
Figure 2. Si851x (Ping Pong Output) Block
Diagram
R1
R2
IIN
The Si85xx is superior to other current sensing
approaches and benefits the system in a number of
ways:
Si850x
VDD2
OUT
RESET LOGIC
Small size: With its 4x4 mm footprint and 1 mm
height, the Si85xx is among the smallest current
sensors available.
INTEGRATOR
SIGNAL CONDITIONING
PICKUP
COIL
Large output signal: The 2.0 V full-scale output
swing offers superior noise immunity versus other
current sensing technologies.
Low loss: The Si85xx adds only 1.3 mΩ (at 25 °C)
to the sensing path making it one of the lowest loss
current sensors available. Low 2 nH primary series
inductance is 2,000 times lower compared to a CT,
and results in significantly less ringing.
AUTO CALIBRATION
LOGIC
TEMP
SENSOR
ADC
NC
IOUT
GND1
GND2
GND3
TRST
VDD1
High precision: The Si8501/2/3 versions are
available with a max error of ±5% of reading; one of
the highest accuracy current sensors available.
Figure 1. Si850x (Single Output) Block Diagram
Ping-Pong output mode (Si851x): Alternately
routes the current measurements from each side of
a full-bridge circuit to separate output pins for
comparison, which is very useful for transformer flux
balancing applications. Eliminates a second CT in a
full-bridge application.
Leading edge noise suppression: Filters out
reflected noise due to long reverse recovery time of
output rectifier. Eliminates the need for external
leading edge blanking circuit.
High common mode voltage: The Si85xx offers up
to 1,000 VDC of isolation making it useful over a
very wide voltage range.
6
Preliminary Rev. 0.1
Si85xx
FAULT output (Si8517/8/9): goes low when external
2.3. Integrator Reset and
Current Measurement
reset timing is in error.
Ease-of-use: Other than conventional power and
grounding techniques, no special board layout
considerations are required. Built-in timing interface
circuits allow already available system switching
signals to be used for reset—no external circuits
required.
The Si85xx measures current flowing from the IIN to
IOUT terminals. Current is allowed to flow in the
opposite direction, but will not be measured (OUT1 and
OUT 2 remain at their minimum values during reverse
current flow. Reverse current flow will not damage the
Si85xx).
2.1. Under Voltage Lockout (UVLO)
To achieve specified accuracy, the integrator capacitor
must be discharged (reset) for time period t prior to the
R
UVLO is provided to prevent erroneous operation during
device start-up and shutdown, or when VDD is
significantly below specified operating range. The
start of every measurement cycle. This cycle-by-cycle
reset is implemented by connecting existing system
gate control signals to the R1–R4 inputs in a way that
resets the integrator when no current is flowing from IIN
to IOUT. To achieve rated accuracy, the reset cycle
must be completed prior to the start of the measurement
cycle. For maximum flexibility, integrator reset operation
can be configured in one of two ways:
Si85xx is in UVLO state when VDD < V
(Figure 3).
UVLO
During UVLO, the output(s) are held at minimum value
regardless of the amount of current flowing from IIN to
IOUT and signals on integrator reset inputs R1-R4 are
ignored. The Si85xx exits UVLO when VDD > (V
+
UVLO
V
).
HYST
Option 1: The start and duration of reset is
determined by the states of the timing
signals applied to R1-R4.
2.2. Device Start-Up
Upon exit from UVLO, the Si85xx performs a voltage
offset and temperature self-calibration cycle. During this Option 2: The timing signals applied to R1-R4 trigger
time, output(s) are held at minimum value and reset
inputs (R1-R4) are ignored. The reset inputs are
enabled at the end of the self-calibration cycle, and an
integrator reset cycle is initiated on the first occurrence
of active signals on R1-R4. A current measurement is
initiated immediately after the completion of the
integrator reset cycle, and the resulting current
waveforms appear on the output pins. This "reset-
measure-reset" pattern repeats throughout steady-state
operation.
the start of reset, and the duration of the
reset is determined by an on-board
programmable reset timer.
VUVLO + VHYST
VDD
First Positive Edge
Following End of Self-Cal
SUPPLY
INTEGRATOR
DON’T CARE
tRP
tRP
RESET
UNDER VOLTAGE
LOCKOUT STATE
START-UP
SELF-CAL CYCLE
Si85xx
STATUS
RESET
tR
MEASURE CURRENT
RESET
tR
tCAL
Si85xx
OUTPUT
VOUTMIN
OUT1, OUT2
VALID
Figure 3. Si85xx Startup and Control Timing
Preliminary Rev. 0.1
7
Si85xx
Integrator reset option 1 is selected by connecting T
2.4. Effect of Operating Frequency on
Output Accuracy
RST
to VDD. In this mode, the Si85xx is held in reset as long
as the signals on R1-R4 satisfy the logic equations of
Tables 3 and 4. It is typically used in applications where
the gate drivers are external to the system controller I.C.
(the gate driver delay ensures reset is completed prior
to the start of measurement).
The Si85xx includes a built-in watchdog timer that
disables measurement and holds OUT or OUT1 and
OUT2 at their minimum values when the timer’s preset
limit is exceeded. This timer limits the operation of the
Si85xx in dc measurement applications. As Figure 5
illustrates, the Si85xx operates down to about 10 kHz
with the nominal measurement error doubling to about
10 percent.
Reset option 2 is selected by connecting a timing
resistor (R
in Figure 4) from the TRST input to
TRST
ground. It is typically used in applications where the
gate drivers are on-board the controller. In this mode,
the on-chip reset timer is triggered when the signals on
R1-R4 satisfy the logic equations of Tables 3 and 4.
Once triggered, the timer maintains integrator in reset
15%
12%
9%
for time duration t as programmed by the value of
R
6%
resistor R
. The user must select the value of
TRST
3%
resistor R
to terminate the reset cycle prior to the
TRST
0%
start of measurement under worst-case timing
10
20
30
40
50
conditions. Note that values of t below the specified
R
value in Section “1. Electrical Specifications” results in
increased integrator output offset error and increased
Frequency (kHz)
Figure 5. Full-Scale Error vs. Frequency
2.5. Effect of Temperature on Accuracy
output noise on VOUT. Moreover, t ’s time is
R
summarized by the following equation:
t = 10 ns/kΩ
R
Offset voltage present at the Si85xx output terminals
(output offset voltage) is calibrated out each time VDD is
applied to the Si85xx; so, its error contribution is
minimized when the temperature at which calibration
occurred is at or near the steady-state operating
temperature of the Si85xx. For example, applying VDD
at 25 °C (offset cal is performed) and operating at 85 °C
will result in a larger offset error than operating at 50 ºC.
The effect of this error is summarized in Figure 6. The
chart is referenced to 25 °C. If the Si85xx is powered up
at 25 °C and then operated at 125 °C with no auto-
calibration performed (i.e., the power is not cycled at
125 °C, which causes an auto-calibration), a 3 percent
measurement error can be expected.
where values of R
that produce a reset time less
< 20 kΩ) should not be used.
TRST
than 200 ns (R
TRST
Si85xx
TRST
RTRST
1.0%
0.5%
Figure 4. Programming Reset Time (tR)
0.0%
-0.5%
-1.0%
-1.5%
-2.0%
-2.5%
-3.0%
-3.5%
0
25
50
75
100
125
Temperature (Celcius)
Figure 6. Differential Temperature
Calibration Error
8
Preliminary Rev. 0.1
Si85xx
Figure 7 shows the Si85xx thermal characteristics over
the temperature range of –40 to +125 ºC. Series
inductance is constant at 2 nH (max) across this same
temperature range.
2.6. Leading Edge Noise Suppression
High-amplitude spikes on the leading edge of the
primary switching waveforms can cause the PWM latch
to be erroneously reset at the start of the switching cycle
when operating in current mode control. To prevent this
problem, leading edge blanking is commonly used to
disable the current comparator during the early portion
of the primary-side switching cycle. The Si85xx
eliminates leading-edge noise spikes by including them
in the signal integration. As shown in the output
waveform of Figure 8, noise present in the input
waveform is eliminated without the use of blanking.
2
1.8
1.6
1.4
1.2
1
0.8
0.6
0.4
0.2
0
-20
0
20
40
60
80
100
120
Temperature (°C)
Figure 7. Series Resistance Thermal
Characteristics
Current Sense
Transformer
Si8502
Figure 8. Leading-Edge Noise Suppression Waveforms (200 kHz, 9.3A Load)
(Si8502 waveform measured directly on OUT pin with no external filter)
Preliminary Rev. 0.1
9
Si85xx
2-wire Ping-Pong mode is useful mainly in non-
overlapping two-phase buck converters, but may also
be used in full-bridge applications. In this output mode,
reset inputs R1 and R2 are used, and input R3 is
grounded. Measured current appears on OUT1 when
R2 is high, and appears on OUT2 when R1 is high as
shown in the full-bridge timing example of Figure 9.
2.7. FAULT Output
The FAULT output (Si8517/8/9) guards against Si85xx
output signal errors caused by missing reset cycles.
FAULT is asserted when a measurement cycle exceeds
the internal watchdog timer times limit of t . FAULT
WD
can be used to alert a local microcontroller or digital
power controller of a current sense failure, or initiate a
system shutdown. To detect faults, tie a 200 kΩ resistor
from TRST/FAULT to VDD.
R1
R2
3. Application Information
3.1. Board Layout
The Si85xx is connected in the series path of the current
to be measured. The Si85xx must be located as far
away from away from transformer and other magnetic
field sources as possible. Like other analog
components, the Si85xx should be powered from a low-
noise DC source, and preferably connected to a low
noise analog ground plane. Recommended bypass
capacitors are 1 µF in parallel with a 0.1 µF, positioned
as close to the Si85xx as possible. When using the
Si850x (single output versions), all 3 ground pins MUST
be connected to the same ground point, and both VDD
and VDD2 pins MUST be tied to VDD.
MEASURE RESET
MEASURE RESET
Si85xx State
tR
tR
OUT1
OUT2
TIME
Figure 9. Full-Bridge Timing Example A
4-Wire Ping-Pong mode is recommended for full-bridge
applications over 2-wire because it uses all four inputs
making the reset function tolerant to single-point signal
failures. In 4-Wire Ping-Pong mode, current appears on
OUT2 when R1 is high and R2 is low; and appears on
OUT1 when R3 is high and R4 is low as shown in the
full-bridge timing example of Figure 10. Table 3 shows
the states of the Mode and R4 inputs that select each
output, and the resulting reset logic functions and truth
tables.
3.2. Device Configuration
Configuring the Si85xx involves the following steps:
1. Selecting an output mode
2. Configuring integrator reset timing
3. Setting integrator reset time t
R
3.2.1. Device Selection
The Si85xx family offers three output modes: Single
output (Si850x), and 2 and 4-Wire Ping Pong (Si851x).
The Si851x products can be configured to operate in all
three of these output modes.
The Si850x products operate ONLY in Single output
mode. Most half-wave and single-phase applications
require only Single output mode, and will typically use
the Si850x. In Single output mode, output current
always appears on the OUT pin (Si850x) or the OUT1
pin (Si851x). A single integrator reset signal is typically
sufficient when operating in this mode.
Ping-Pong mode routes the current waveform to two
different output pins on alternate measurement cycles.
It is useful in full-wave and push-pull topologies where
external circuitry can be used to monitor and/or control
transformer flux balance. (Note: The Applications
section of this data sheet (Section 3) shows design
examples using both output modes in various power
topologies.)
10
Preliminary Rev. 0.1
Si85xx
3.2.2. Selecting Reset Timing Signals
Reset timing signals should be chosen to meet the
following conditions:
R1
R2
Satisfy reset time t
R
Not overlap integrator reset into the desired
measurement period
Not violate reset watchdog timeout period t
WD
3.2.3. Configuring Integrator Reset
Per Section “2. Functional Overview”, the integrator
must be reset (zeroed) prior to the start of each
measurement cycle to achieve specified measurement
accuracy. This reset must be synchronized with the
system switch timing signals to ensure current is
measured during the appropriate time, so the Si85xx
integrator reset circuitry uses system timing as its
reference. Timing signals connect to reset inputs R1
through R4 where built-in logic functions allow the user
to choose the conditions that cause an integrator reset
event. Important note: reset inputs R1–R4 are rated to a
maximum input voltage of VDD. External resistor
dividers must be used when connecting driver output
signals to R1–R4 that swing beyond VDD.
R3
R4
MEASURE RESET
MEASURE RESET
tR
tR
OUT1
OUT2
Figure 10. Full-Bridge Timing Example B
Preliminary Rev. 0.1
11
Si85xx
Table 3. Si850x Reset Mode Summary
Output Mode
Single-Ended
R2
0
R1
Reset State*
Logic Expression
RESET = XOR [R1, R2]
0
1
0
1
0
1
1
0
0
1
1
*Note: Device is in reset when Reset State = 1.
Table 4. Si851x Output and Reset Mode Summary
Part #
Output Mode MODE Input R4 R3 R2 R1 Reset State*
Logic Expression
RESET = XOR [R1, R2]
Si850x
Single-Ended
—
—
—
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
0
1
0
1
0
*Note: Device is in reset when Reset State = 1.
12
Preliminary Rev. 0.1
Si85xx
Table 4. Si851x Output and Reset Mode Summary (Continued)
Part #
Output Mode MODE Input R4 R3 R2 R1 Reset State*
Logic Expression
Si851x
Single-Ended
1
0
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
0
1
0
1
0
1
0
0
1
0
0
0
1
0
0
0
1
0
0
0
1
1
1
1
1
RESET = XOR [R1, R2]
RESET = XNOR [R1, R2]
2-Wire Ping Pong
4-Wire Ping Pong
1
0
1
0
RESET = [R1 & R2] | [R3 & R4]
1
*Note: Device is in reset when Reset State = 1.
As shown in Table 3, the Si850x integrator reset logic is a simple XOR gate where reset is maintained (or triggered,
depending on use of the TRST input) when states of reset inputs R1 and R2 are not equal.
Figure 11 shows the logic for the Si851x products, where any one of three reset logic functions can cause
integrator reset. The output mode (Si851x) is determined by the states of the Mode and R4 inputs, as shown in
Table 4.
As explained in Section 2.3, the signals applied to R1-R4 can control integrator reset in real time (option 1), or can
trigger a reset event of programmable duration (option 2). Referring to Figure 11, reset timing is exclusively a
function of the signals applied to R1-R4 when TRST is tied to VDD. If not connected to VDD, the reset timer is
enabled and TRST MUST be connected through a resistor to ground to set the reset duration (t ). Note the reset
R
timer is retriggerable, and generates a timed integrator discharge pulse whenever the reset logic output transitions
from low to high.
Preliminary Rev. 0.1
13
Si85xx
MODE = 1
R4 = 0
TRST = R1 to GND
TRST = VDD
Output 1
Output 2
Reset triggered by inputs
R1–R4. Reset time (tR) set
Reset timing determined
only by inputs R1–R4.
R1
R2
R3
R4
by value of resistor RTRST
.
MODE = 1
R4 = 1
RESET
TIMER
TRST
PGM
OUT
CLK
1
0
+
VREF
MODE = 0
Output 3
Logic level gate
control signals
(to Rn inputs)
SYSTEM
CONTROLLER
INTEGRATOR
External
Driver
Internal
Driver
Logic level gate
control signals
(to Rn inputs)
Required if driver
output voltage > VDD
Figure 11. Si851x Integrator Reset Logic
14
Preliminary Rev. 0.1
Si85xx
3.2.4. Setting Reset Time t
R
The programmable reset timer is triggered when the states of the signals applied to R1–R4 cause the associated
logic expression (Tables 3 and 4) to go high (transition to the TRUE state). Because this timer is re-triggerable, R1–
R4 must remain TRUE for the duration of the desired t as shown in Figure 12. Should R1–R4 transition FALSE
R
during t , integrator reset will be immediately halted resulting in lower measurement accuracy due to higher
R
integrator offset error.
CURRENT
R1–R4 TRUE
for programmed
tR (minimum)
TRUE
R1–R4 STATE
FALSE
Programmed
0 ns (min)
value of tR
Si85xx STATUS
Si85xx OUTPUT
RESET
MEASURE
Figure 12. Correct tR Programming Using Resistor from TRST Input to Ground
Preliminary Rev. 0.1
15
Si85xx
3.2.5. Measurement Watchdog Timer and FAULT Output
A built-in watchdog timer disables measurement and holds OUT or OUT1 and OUT2 at their minimum values when
the time between integrator resets exceeds t . The output signal from this watchdog is available on the FAULT
WD
output pin (Si8517/8/9 only).
t1
t2
Reset
Trigger
System
Timing Phase
Measurement
Period
Measurement
Period
tWD
tWD
tWD
Output
FAULT
tR
tR
Figure 13. Measurement Watchdog Timer Operation
As shown in Figure 13, the time between integrator resets for system timing phase t is greater than watchdog
1
period t . As a result, measurement occurs until t
is exceeded, at which time the output is immediately forced
WD
WD
to minimum value and FAULT transitions low. Further measurements are inhibited until the application of another
integrator reset, which also resets the watchdog driving FAULT high, and enables another measurement cycle.
This process continues until t
is no longer violated, as shown in period t where normal operation is restored.
WD
2
The current measurements made in period t1 will have reduced accuracy versus those made within the specified
operating frequency range.
16
Preliminary Rev. 0.1
Si85xx
3.3. Single-Phase Buck Converter Example
In this example, the Si850x is configured to operate in a single-phase synchronous buck converter (Figure 14).
This converter has a PWM frequency of 1 MHz, and a maximum duty cycle of 80%.
VDD
VIN
C1
C2
0.1 µF
1 µF
VDD1 VDD2
R2
GND1
GND2
GND3
IIN
Si850x
IOUT
TRST
R1
RTRST
2 Vpp
OUT
Q1
L1
PH1
PWM
PH2
VOUT
Current
I = 0
I > 0
C3
Q2
Si850x State
RESET
100 ns
MEASURE
PH2
Figure 14. Si850x Single-Phase Buck Converter
This is an example of a half-wave application that can be addressed with Single-Ended output mode. The PWM
–6
–6
period is calculated to be 1/10 = 1.0 µs, and the worst-case value t is 0.2 x 1.0 x 10 = 200 ns at 80%
R
maximum duty cycle (R
= 20 kΩ). In this example, the current measurement is made when the buck switch is
TRST
on, so PH2 is chosen as the reset signal by connecting PH2 to R1 and grounding the R2 and R3. The PH2 signal
can be obtained at the input of the driver external to the PWM controller, or the output of the controller's internal
driver (through a resistor divider if the driver output swings beyond the device VDD range).
Preliminary Rev. 0.1
17
Si85xx
3.4. Full-Bridge Converter Example
The full-bridge circuit of Figure 15 uses an Si851x configured in 4-Wire Ping-Pong output mode. The switching
frequency of this phase-shifted full-bridge is 150 kHz, and the maximum control phase overlap is 70%.
VIN
VDD
VDD
IIN
OUT1
OUT2
PH1
PH2
OUT1
OUT2
MODE
GND
C1
C2
Si851x
0.1 µF
1 µF
VDD
TRST
R1 R2 R3 R4
IOUT
PH3
PH4
Q1
1–4
1–2
2–3
3–4
Switches Turned ON
Si85xx State
PH1
PH2
Q2
Q4
MEASURE
RESET
MEASURE
RESET
TI
OUT1
OUT2
Q3
PH3
PH4
Figure 15. Full-Bridge Converter
3
Given the 150 kHz switching frequency (duty cycle fixed at 50%), the equivalent period is 1/150 x 10 = 6.6 µs. At
–6
70% maximum overlap, this equates to a worst-case t value of is 0.3 x 6.6 x 10 = 1.98 µs; the default value for
R
t
can therefore be used, and is selected by connecting TRST to VDD. As shown in the timing diagram of
R
Figure 15, integrator reset occurs when current circulates between Q1 and Q2, and between Q3 and Q4 (i.e. when
current is not being sourced from VIN). The external driver delay ensures reset is complete prior to the start of
measurement.
18
Preliminary Rev. 0.1
Si85xx
3.5. Push-Pull Converter Example
The Push-Pull converter of Figure 16 uses 2-Wire Ping Pong output mode. As shown in the timing diagram, the
integrator reset occurs when the inputs of both the PH1 and PH2 drivers are low. As shown, TRST is connected to
VDD, selecting the default value of t (250 ns). Assuming an 80% maximum duty cycle, this value of t would
R
R
deliver specified accuracy over a PWM frequency range of 50 to 400 kHz. Frequencies above 400 kHz would
require the selection of a lower t value by connecting a resistor from TRST to ground.
R
VDD
VIN
C1
C2
0.1 µF
1 µF
VDD MODE
IIN
OUT1
OUT2
R4
TRST
Si851x
R3
R2
GND
R1
IOUT
Q1
PH1
PH2
PH2
T1
MEASURE RESET MEASURE RESET MEASURE
Si85xx Status
OUT1
Q2
OUT2
PH1
Figure 16. Push-Pull Example Using Default tR Value
Preliminary Rev. 0.1
19
Si85xx
4. Pin Descriptions—Si85xx
12-Pin QFN
R1
R1
IIN
IIN
R2
R3
R4
R2
GND2
Si850x
Si851x
GND3
OUT
NC
OUT1
OUT2
IOUT
IOUT
Figure 17. Example Pin Configurations
Table 5. Si85xx Family Pin Descriptions
Pin#
Si850x
Description
Si851x
Description
Pin Name
Pin Name
1
2
3
4
5
R1
R2
Integrator reset input 1
Integrator reset input 2
Ground
R1
R2
Integrator reset input 1
Integrator reset input 2
Integrator reset input 3
Integrator reset input 4
GND2
GND3
OUT
R3
R4
Output
OUT1
Output in single-ended output mode, or
one of two outputs in Ping-Pong mode.
6
7
NC
No connect
OUT2
TRST
GND
IOUT
IIN
Second of two Ping-Pong mode outputs
Reset time control
TRST
GND1
IOUT
IIN
Reset time control
Ground
8
Ground
9
Current output terminal
Current input terminal
Power supply input
Current output terminal
Current input terminal
Power supply input
10
11
12
VDD1
VDD2
VDD
MODE
Mode control input
20
Preliminary Rev. 0.1
Si85xx
5. Ordering Guide
P/N
Full Scale
Current (A)
Full Scale
Error
Temp Range
Pin 7 Function
Output Mode Package
(°C)
(% of Reading)
Si8501-B-GM
Si8502-B-GM
Si8503-B-GM
Si8504-B-IM
Si8505-B-IM
Si8506-B-IM
Si8511-B-GM
Si8512-B-GM
Si8513-B-GM
Si8514-B-IM
Si8515-B-IM
Si8516-B-IM
Si8517-B-GM
Si8518-B-GM
Si8519-B-GM
5
±5
±20
±5
–40 to +85 Integrator Reset Time
Programming Input
Single
4x4 mm
QFN
10
20
5
–40 to +125 Integrator Reset Time
Programming Input
10
20
5
–40 to +85 Integrator Reset Time Ping-Pong
Programming Input
10
20
5
±20
±5
–40 to +125 Integrator Reset Time
Programming Input
10
20
5
–40 to +85
FAULT Output
10
20
Note: All packages are Pb-free and RoHS compliant. Moisture Sensitivity level is MSL2 with peak reflow temperature of
260 ºC according to the JEDEC industry classification, and peak solder temperature.
Preliminary Rev. 0.1
21
Si85xx
6. Package Outline—12-Pin QFN
Figure 18 illustrates the package details for the Si85xx. Table 6 lists the values for the dimensions shown in the
illustration.
Figure 18. 12-Pin QFN Package Diagram
Table 6. QFN-12 Package Diagram Dimensions
Dimension
MIN
NOM
MAX
A
b
0.80
0.25
0.85
0.85
0.30
0.90
0.35
0.95
c
0.90
D
4.00 BSC.
0.50 BSC.
4.00 BSC.
2.45 BSC.
1.30 BSC.
0.75 BSC.
0.40
e
E
f
g
k
L
0.35
0.03
0.45
—
0.45
0.08
0.55
0.05
0.05
0.08
0.05
0.05
L1
L2
aaa
bbb
ccc
ddd
eee
0.05
0.50
—
—
—
—
—
—
—
—
—
22
Preliminary Rev. 0.1
Si85xx
NOTES:
Preliminary Rev. 0.1
23
Si85xx
CONTACT INFORMATION
Silicon Laboratories Inc.
400 West Cesar Chavez
Austin, TX 78701
Tel: 1+(512) 416-8500
Fax: 1+(512) 416-9669
Toll Free: 1+(877) 444-3032
Email: PowerProducts@silabs.com
Internet: www.silabs.com
The information in this document is believed to be accurate in all respects at the time of publication but is subject to change without notice.
Silicon Laboratories assumes no responsibility for errors and omissions, and disclaims responsibility for any consequences resulting from
the use of information included herein. Additionally, Silicon Laboratories assumes no responsibility for the functioning of undescribed features
or parameters. Silicon Laboratories reserves the right to make changes without further notice. Silicon Laboratories makes no warranty, rep-
resentation or guarantee regarding the suitability of its products for any particular purpose, nor does Silicon Laboratories assume any liability
arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation conse-
quential or incidental damages. Silicon Laboratories products are not designed, intended, or authorized for use in applications intended to
support or sustain life, or for any other application in which the failure of the Silicon Laboratories product could create a situation where per-
sonal injury or death may occur. Should Buyer purchase or use Silicon Laboratories products for any such unintended or unauthorized ap-
plication, Buyer shall indemnify and hold Silicon Laboratories harmless against all claims and damages.
The sale of this product contains no licenses to Power-One’s intellectual property. Contact Power-One, Inc. for appropriate licenses.
Silicon Laboratories and Silicon Labs are trademarks of Silicon Laboratories Inc.
Other products or brandnames mentioned herein are trademarks or registered trademarks of their respective holders.
24
Preliminary Rev. 0.1
SI8503-B-GM 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
SI8503-C-GM | ETC | Si85XX UNIDIRECTIONAL AC CURRENT SENSORS | 获取价格 | |
SI8503-C-IM | SILICON | Analog Circuit, 1 Func, 4 X 4 MM, 1.00 MM HEIGHT, ROHS COMPLIANT, QFN-12 | 获取价格 | |
SI8503-C-IS | ETC | Si85XX UNIDIRECTIONAL AC CURRENT SENSORS | 获取价格 | |
SI8504-B-IM | SILICON | UNIDIRECTIONAL AC CURRENT SENSORS | 获取价格 | |
SI8504-C-IM | ETC | Si85XX UNIDIRECTIONAL AC CURRENT SENSORS | 获取价格 | |
SI8505-B-IM | SILICON | UNIDIRECTIONAL AC CURRENT SENSORS | 获取价格 | |
SI8505-C-IM | ETC | Si85XX UNIDIRECTIONAL AC CURRENT SENSORS | 获取价格 | |
SI8506-B-IM | SILICON | UNIDIRECTIONAL AC CURRENT SENSORS | 获取价格 | |
SI8506-C-IM | ETC | Si85XX UNIDIRECTIONAL AC CURRENT SENSORS | 获取价格 | |
SI850X | SILICON | UNIDIRECTIONAL AC CURRENT SENSORS | 获取价格 |
SI8503-B-GM 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6