SNP-AF87-3 [SKYNET]

Medical & ITE Switching Adapter;
SNP-AF87-3
型号: SNP-AF87-3
厂家: Skynet Electronic Copyright    Skynet Electronic Copyright
描述:

Medical & ITE Switching Adapter

文件: 总4页 (文件大小:602K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Rated  
Peak  
SNP-AF8 Series  
72W  
100W  
Medical & ITE  
Switching Adapter  
Features:  
●ꢀ  
Peak load (1.3 ~ 1.5 x rated current, Vo=rated for 5 sec)  
Design for BF application  
DoE Level VI Eco-design  
●ꢀ  
●ꢀ  
●ꢀ  
●ꢀ  
●ꢀ  
●ꢀ  
With ITE and Medical safety  
Safety class I / II and EMI class B  
-20oC to +60oC operating temperature  
5,000m operation altitude  
Applications:  
●ꢀ  
For DoE EPS level VI energy saving application, such  
as electronics and office equipment.  
For EMI class B application, such as home healthcare  
●ꢀ  
device, monitors and other medical devices.  
For peak load application, such as motor drive, coffee  
72 x 145 x 42 (mm)  
●ꢀ  
machine, vending machine, gaming machine, monitors  
and other industrials.  
General Specifications:  
Input voltage ......................................... 90 VAC to 264 VAC  
Input frequency ............................................. 47 Hz to 63 Hz  
Inrush current ............................................ < 80A at 230VAC  
Average efficiency ............ > 89% at 25%, 50%, 75%, 100%  
of rated load and 115Vac/230Vac input  
No-load input power ................................................ < 0.15W  
Hold up time ......................................................16ms typical  
Over load/Short citcuit protection ................... auto recovery  
Over voltage protection ............................................ latch of  
Operating temperature ..................................... -20oC to 60oC  
derating: 2.5% / oC > 40oC  
Storage temperature ..................................... -20oC to +85oC  
EMI ................................................................ FCC class "B"  
CISPR 22 level "B"  
Harmonics............................................EN61000-3-2, class A  
EMS...................................... EN61000-4-2,-3,-4,-5,-6,-8,-11  
Safety ............................................. UL60601-1, UL60950-1  
CSA C22.2 No. 60950-1(cUL)  
TUV EN60601-1, EN60950-1  
EC Code of Conduct  
Energy Saving ........................................  
for EPS Version (Tier 2)  
Mechanical Specifications:  
Notes:  
1.  
Size:  
72 x 145 x 42 (mm)  
Output Connectors:  
2.  
145.0 (5.71")  
PIN VOLTAGE  
1
3
4
2
+V  
RTN  
RTN  
+V  
EARTH  
72.0  
(2.83")  
3.  
Input Socket:  
C14  
4.  
5.  
6.  
7.  
8.  
Cable length is 1.5m approx.  
Power ON indication LED is on top of Box.  
Box Color is Black.  
This product is RoHS compliant.  
Packing:  
Net weight: 470 g approx. / unit  
42.0  
(1.65")  
Gross weight: 12 kg approx. / carton, 20 units / carton  
Carton size (mm): 503 (L) x 362 (W) x 300 (H) (mm)  
-Jim-  
10 years Warranty (contact Skynet's Distributors for details)  
** This data sheet is only for models selection. For business, engineering specification by model must be used.  
NOV. 2016  
4-1  
Rated  
Peak  
SNP-AF8 Series  
72W  
100W  
Medical & ITE  
Switching Adapter  
Output Specifications:  
MODEL  
NO.  
OUTPUT  
RAIL  
LOAD  
INITIAL  
STEP EFFICIENCY  
AVERAGE  
ACCURACY  
EFFICIENCY.  
MIN. RATED MAX. PEAK  
@ 25% LOAD @ 50% LOAD @75% LOAD @ 100% LOAD  
SNP-AF87-3  
SNP-AF87-H  
+12V  
+24V  
0A  
0A  
6A  
8.4A  
4.6A  
+11.4V~+12.6V  
89%  
89%  
89%  
89%  
89%  
89%  
89%  
89%  
> 89%  
> 89%  
SNP-AF89-3  
SNP-AF89-H  
3.2A  
+22.8V~+25.2V  
Note:  
1. Output Load:  
Rated 72W~77W for convection cooling.  
2. At peak load, the output can last for 5 seconds without shut down.  
3. At factory, in 60% rated load condition, each output is checked to be within voltage accuracy.  
4. Line regulation is defined by changing ±10% of input voltage from nominal line at rated load.  
5. Load regulation is defined by changing ±40% of measured output load from 60% rated load.  
6. Ripple & noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.47uF capacitor at rated load and nominal  
line.  
7. Hold up time is measured from the end of the last charging pulse to the time which the main output drops down to low limit of main output at rated load  
and nominal line.  
8. Efficiency is measured at rated load, and nominal line.  
9. SNP-AF8x-H is for Home Healthcare.  
-Jim-  
** This data sheet is only for models selection. For business, engineering specification by model must be used.  
4-2  
NOV. 2016  
Rated  
Peak  
SNP-AF8 Series  
72W  
100W  
Medical & ITE  
Switching Adapter  
Performance for SNP-AF87-3:  
1. Switching frequency ripple  
2. Line frequency ripple  
+12V/6A  
+12V/6A  
100mV/div, 5us/div  
100mV/div, 5ms/div  
3. Output turn on wave form  
4. Output turn off wave form  
+12V/6A  
+12V/6A  
5.0V/div, 10ms/div  
5.0V/div, 10ms/div  
5. Hold-up time  
6. Over voltage protection  
Trip point around 14.5V (60% Rated load)  
5.0V/div  
100V/div  
Primary DC  
10ms/div  
5.0V/div, 10ms/div  
-Jim-  
** This data sheet is only for models selection. For business, engineering specification by model must be used.  
NOV. 2016  
4-3  
Rated  
Peak  
SNP-AF8 Series  
72W  
100W  
Medical & ITE  
Switching Adapter  
7. +12V step response  
8. FCC B  
+12V  
0.5V/div, 2ms/div  
+12V step from 1.2A to 6A  
9. EN 55022 B  
10. Power derating curve  
60oC  
-20oC  
40oC  
-Jim-  
** This data sheet is only for models selection. For business, engineering specification by model must be used.  
4-4  
NOV. 2016  

相关型号:

SNP-AF87-H

Medical & ITE Switching Adapter
SKYNET

SNP-AF89-3

Medical & ITE Switching Adapter
SKYNET

SNP-AF89-H

Medical & ITE Switching Adapter
SKYNET

SNP-B045

Machinery Power
SKYNET

SNP-B047

Machinery Power
SKYNET

SNP-B048

Machinery Power
SKYNET

SNP-B049

Machinery Power
SKYNET

SNP-B065

Machinery Power
SKYNET

SNP-B067

Machinery Power
SKYNET

SNP-B068

Machinery Power
SKYNET

SNP-B069

Machinery Power
SKYNET

SNP-B105

Machinery Power
SKYNET