CINT3110A1708K01 [SLPOWER]

The CINT3110 Series are industrial grade, high efficiency, triple output power supplies in a small 2” x 4” size.; 该CINT3110系列是工业级,高效率,三路输出电源,在小2A ???? X 4A ????尺寸。
CINT3110A1708K01
型号: CINT3110A1708K01
厂家: SL Power Electronics    SL Power Electronics
描述:

The CINT3110 Series are industrial grade, high efficiency, triple output power supplies in a small 2” x 4” size.
该CINT3110系列是工业级,高效率,三路输出电源,在小2A ???? X 4A ????尺寸。

文件: 总10页 (文件大小:1003K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
CINT3110  
110W Triple Output  
Industrial Series  
Features  
.
.
.
.
.
.
2” x 4” x 1.3” Package  
Suitable for 1U Applications  
110W w/air, 80W convection cooled  
Universal Input 90-264Vac  
Efficiency 87% typical  
Approved to CSA/EN/IEC/UL60950-1,  
2nd Edition  
.
.
.
.
Power Fail Signal  
Remote Sense  
3 Year Warranty  
RoHS Compliant  
Description  
The CINT3110 Series are industrial grade, high efficiency, triple output power supplies in a small 2” x 4” size. The  
CINT3110 family is ideal for Industrial and ITE applications requiring multiple outputs and small footprint. Compliant to  
IEC60950-1 2nd edition, the CINT3110 models feature outputs of 5/±12V, 5/±15V, 5/±24V, includes a Power Fail/DC OK  
signal, and meet Class B Conducted EMI.  
Model Selection  
Model  
Output Current**  
Ripple &  
Noise***  
Total  
Regulation  
OVP  
Threshold  
Number  
Volts*  
5V  
w/200LFM air  
Convection  
V1  
V2  
V3  
V1  
V2  
V3  
V1  
V2  
V3  
14.0A  
6.0A  
1.0A  
14.0A  
4.5A  
1.0A  
12.0A  
4.0A  
1.0A  
10.0A  
1.0% pk-pk  
1.0% pk-pk  
2.0% pk-pk  
1.0% pk-pk  
1.0% pk-pk  
2.0% pk-pk  
1.0% pk-pk  
1.0% pk-pk  
2.0% pk-pk  
7.5V max.  
115%-135%  
115%-135%  
7.5V max.  
2%  
CINT3110A0508K01  
CINT3110A1708K01  
CINT3110A1908K01  
12V  
-12V  
5V  
4.5A  
1.0A  
10.0A  
3.5A  
1.0A  
8.0A  
3.0A  
1.0A  
3%  
10%  
2%  
15V  
-15V  
5V  
115%-135%  
115%-135%  
7.5V max.  
3%  
10%  
2%  
24V  
115%-135%  
115%-135%  
3%  
-24V  
10%  
Notes:  
*
5V output is adjustable with +/-10% range  
** Total convection power is 80 Watts.  
*** Measured with noise probe directly across output terminals, and load terminated with 0.1μF ceramic and 10μF low ESR capacitors. Ripple & Noise of V2 at  
no load is 2% maximum.  
General Specifications  
Less than 2 sec. @115Vac (inversely  
proportional to input voltage and thermistor  
temperature)  
100-240Vac, ±10%, 47-63Hz, 1  
120–370Vdc  
AC Input  
Turn On Time  
Hold-up Time  
115Vac: 1.5A, 230Vac: 0.75A  
16mS typical at 110W, 120Vac input  
Input Current  
www.slpower.com  
CINT3110 REV 1.1, 26-NOV-12  
1
CINT3110  
110W Triple Output  
Industrial Series  
General Specifications (continued)  
264Vac, cold start: will not exceed 45A  
AC Power Fail, DC OK  
Inrush Current  
Signals  
Overload  
Protection  
F1, F2: 2.5A, 250Vac fuses provided on all  
models  
150%-300% above rating for V2 & V3, 110%-  
200% for V1. Hiccup Mode  
Input Fuses  
Earth Leakage  
Current  
Short Circuit  
Protection  
Provided - no damage will occur if the output is  
shorted.  
<290μA@264Vac, 60Hz, NC  
Overvoltage  
Protection  
87% typical at 230Vac  
See models chart for trip range.  
PFC: 75kHz typical  
Efficiency  
110W continuous with 200 lfm airflow, 80W  
convection cooled – See chart for specific  
voltage model ratings.  
Switching  
Frequency  
Output Power  
500µS typ. for return to within 0.5% of  
nominal, 50% load step. i/t <0.2A/μS.  
Max Volt Deviation = 3%  
Input-Output: 4000Vac  
Input-Ground: 1800Vac  
Output-Ground: 500Vac  
Transient  
Response  
Isolation  
Operating  
Temperature  
See models chart  
-10°C to +70°C  
Ripple and Noise  
Output Voltage  
Temperature  
Derating  
Derate output power linearly above 50°C to 50%  
at 70°C  
See models chart  
Voltage  
Adjustability  
Storage  
Temperature  
+/-10% from nominal on 5V output  
Not required  
-40°C to +85°C  
Operating: -500 to 10,000 ft.  
Non-operating: -500 to 40,000 ft.  
Minimum Load  
Altitude  
See models chart  
5% to 95%, non-condensing  
Total Regulation  
Relative Humidity  
Operating: 0.003g²/Hz, 1.5grms overall, 3  
axes, 10 min/axis  
Non-Operating: 0.026g²/Hz, 5.0grms overall,  
3 axes, 1 hr/axis  
Operating: Half-sine, 20gpk, 10ms, 3 axes, 6  
shocks total  
Non-Operating: Half-sine, 40 gpk, 10 ms, 3  
axes, 6 shocks total  
Vibration  
Shock  
W: 2.0” x L: 4.0” x H: 1.3”  
200g  
EN/CSA/UL/IEC 60950-1, 2nd Edition  
Dimensions  
Weight  
Safety Standards  
MTBF  
245,000 hours, 25°C Ambient, 110Vac input  
Auxiliary Signals  
During normal operation, stays HIGH. Signal  
goes LOW with at least 6mS warning before  
loss of DC output from AC failure.  
Open collector logic signal goes and stays HIGH  
100mS to 500mS after main output reaches  
regulation.  
AC Power Fail:  
DC OK:  
(5V output, optional) Will compensate for 0.5V  
drop min. Will operate without remote sense  
connected. Reverse connection protected.  
Remote Sense:  
Notes:  
1. Specifications are for convection rating at factory settings at 115 Vac input, 25°C ambient unless otherwise stated.  
2. For DC input an external DC safety rated fuse must be used.  
www.slpower.com  
CINT3110 REV 1.1, 26-NOV-12  
2
CINT3110  
110W Triple Output  
Industrial Series  
EMI/EMC Compliance  
EN55011/22 Class B, FCC Part 15, Subpart B, Class B  
Conducted Emissions  
EN55011/22 Class A; FCC Part 15, Subpart A, Class A  
EN61000-4-2, Criteria A, 6kV Contact Discharge, 8kV air discharge  
EN61000-4-3, 3V/m. Criteria A  
Radiated Emissions  
Static Discharge Immunity  
Radiated RF Immunity  
EFT/Burst Immunity  
EN61000-4-4, 2kV/5kHz, Criteria A  
EN61000-4-5, 1kV differential, 2kV common-mode, Criteria A  
EN61000-4-6, 3Vrms, Criteria A  
Line Surge Immunity  
Conducted RF Immunity  
Power Frequency Magnetic Field Immunity  
Voltage Dip Immunity  
Line Harmonic Emissions  
Flicker Test  
EN61000-4-8, 3A/m, Criteria A  
EN61000-4-11, 0% Vin, 0.5cycle; 40% Vin, 5 cycles; 70% Vin, 25 cycles;  
Criteria A  
EN61000-3-2, Class A, B, C, & D  
EN61000-3-3, Complies (dmax<6%)  
Mechanical Drawing  
Notes:  
1. All dimensions in inches (mm), tolerance is ±.02”.  
2. Mounting holes should be grounded for EMI purpose  
3. Mounting J101 is safety ground connection  
4. This power supply requires mounting on metal standoffs 0.20” (5 m) in height.  
www.slpower.com  
CINT3110 REV 1.1, 26-NOV-12  
3
CINT3110  
110W Triple Output  
Industrial Series  
Connector Information  
Input Connector  
J100  
Ground  
J101  
DC Output Connector  
J200  
Signal Connector  
J300  
PIN 1) Power Fail/DC OK  
PIN 2) GND  
PIN 3) +Remote Sense  
PIN 4) –Remote Sense  
PIN 1) AC NEUTRAL  
PIN 1) +V1  
PIN 2) +V1  
PIN 3) GND  
PIN 4) GND  
PIN 5) GND  
PIN 6) GND  
PIN 7) V2  
PIN 8) V3  
PIN 2) EMPTY  
PIN 3) AC LINE  
0.187” FASTON TAB  
Mating Connector:  
Molex 09-50-3031  
Pins= 08-52-0072  
Mating Connector:  
JST VHR-8N  
Pins = SVH-21T-P1.1  
Mating Connector:  
Molex 51065-0400  
Pins = 50212-8100  
Mating Connector:  
Molex 01-90020001  
Isolation Specifications  
Parameter  
Conditions/Description  
Min  
Nom  
Max  
Units  
Input/Ground  
Input/Output  
Output/Ground  
Basic  
Reinforced  
Operational  
Insulation Safety Rating  
Input/Ground  
Input/Output  
Output/Ground  
1800  
4000  
500  
Vac  
Vac  
Vac  
Electric Strength Test Voltage  
-
-
Leakage Current  
Parameter  
Conditions/Description  
Max  
Normal Condition (NC)  
Single Fault Condition (SFC)  
290µA  
420µA  
Earth Leakage Current  
Touch Current  
Normal Condition (NC)  
Single Fault Condition (SFC)  
90µA  
170µA  
Input Specifications  
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.  
Parameter  
Conditions/Description  
Min  
Nom  
Max  
Units  
Input Voltage  
Input Frequency  
Input Current  
90  
47  
115/230  
50/60  
264  
63  
Vac  
Hz  
A
115Vac/max load  
230Vac/max load  
1.5  
Input Current  
Inrush Current  
0.75  
45  
A
A
264Vac, cold start, 25°C  
-
-
-
Vi nom, Io nom  
CINT3110A0508K01  
CINT3110A1708K01  
CINT3110A1908K01  
Efficiency  
87%  
-
%
Output Specifications  
Parameter  
Conditions/Description  
Min  
Nom  
Max  
Units  
Output Current V1  
Output Current V2  
Output Current V3  
0
0
0
10.0  
4.5  
1
14.0  
6.0  
1
ADC  
CINT3110A0508K01  
Output Current V1  
Output Current V2  
Output Current V3  
0
0
0
10.0  
3.5  
1
14.0  
4.5  
1
CINT3110A1708K01  
CINT3110A1908K01  
ADC  
ADC  
Output Current V1  
Output Current V2  
Output Current V3  
0
0
0
8.0  
3.0  
1
12.0  
4.0  
1
www.slpower.com  
CINT3110 REV 1.1, 26-NOV-12  
4
CINT3110  
110W Triple Output  
Industrial Series  
Output Specifications (continued)  
Parameter  
Conditions/Description  
Min  
-2  
Nom  
Max  
Units  
Static Line Regulation V1  
Static Line Regulation V2  
Static Line Regulation V3  
Vi min-Vi max, Vi nom, 0-100% Io1 max  
-
2
% Vo nom  
Vi min-Vi max, Vi nom, 0-100% Io2 max  
Vi min-Vi max, Vi nom, 0-100% Io3 max  
Vi min-Vi max, Vi nom, 0-100% Io1 max  
Vi min-Vi max, Vi nom, 0-100% Io2 max  
Vi min-Vi max, Vi nom, 0-100% Io3 max  
Vin = 120Vac, Po = 110W  
-3  
-10  
-2  
-
-
-
-
-
-
3
10  
2
% Vo nom  
% Vo nom  
% Vo nom  
% Vo nom  
% Vo nom  
mS  
Static Load Regulation V1  
(Droop Characteristic)  
Static Load Regulation V2  
(Droop Characteristic)  
-3  
3
Static Load Regulation V3  
(Droop Characteristic)  
-10  
10  
-
Hold-Up Time  
Dynamic Load Regulation V1, V2, V3  
Start-Up Time  
16  
0
0
0
0
0
3
% Vo nom  
S
Load change =50%, di/dt = 0.2A/μS  
Vin = 115Vac, Io nom  
-
2
Ripple & Noise V1  
1%  
1%  
2%  
% Vo nom  
% Vo nom  
% Vo nom  
20MHz bandwidth  
20MHz bandwidth  
20MHz bandwidth  
Ripple & Noise V2  
Ripple & Noise V3  
Protection  
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.  
Parameter  
Input Fuse  
Conditions/Description  
T2.5A/250V internal fuse in both line & neutral  
2KV(CM) and 1KV(DM) surge  
Min  
Nom  
Max  
Units  
Not user accessible  
Input Transient Protection  
Short Circuit Protection  
Overload Protection  
Overvoltage Protection  
2
KV (CM)  
Hiccup Mode  
Hiccup Mode  
Latching Type, recycle AC input to reset  
See models chart for trip ranges  
Characteristic Curves (Note: All waveforms below are based on CINT3110A0508K01 model)  
Output vs. Temperature  
80W convection cooled and 110W continuous with 200 LFM airflow. Derate output power to 50% at 70C.  
www.slpower.com  
CINT3110 REV 1.1, 26-NOV-12  
5
CINT3110  
110W Triple Output  
Industrial Series  
Ripple & Noise  
To verify that the output ripple and noise does not exceed the level specified in the product specification. Measured using a scope probe socket with  
0.1µF ceramic and a 10µF electrolytic capacitor connected in parallel across it, BW limit with 20MHz.  
Output Transient Response V1  
50% load step within the regulation limits of minimum and maximum load, di/dt<0.2A/μSec. Recovery time not specified as there is no laps in regulation  
with a 50% Load Step. Maximum voltage deviation is 3%.  
Output Transient Response V2  
50% load step within the regulation limits of minimum and maximum load, di/dt<0.2A/μSec. Recovery time not specified as there is no laps in regulation  
with a 50% Load Step. Maximum voltage deviation is 3%.  
www.slpower.com  
CINT3110 REV 1.1, 26-NOV-12  
6
CINT3110  
110W Triple Output  
Industrial Series  
Output Transient Response V3  
50% load step within the regulation limits of minimum and maximum load, di/dt<0.2A/μSec. Recovery time not specified as there is no laps in regulation  
with a 50% Load Step. Maximum voltage deviation is 3%.  
Output Overload Characteristic V1  
Supply shall protect itself against Overload conditions. The Power Supply shall recover from Overload Conditions without operator intervention.  
Output Overload Characteristic V2  
www.slpower.com  
CINT3110 REV 1.1, 26-NOV-12  
7
CINT3110  
110W Triple Output  
Industrial Series  
Output Overload Characteristic V3  
Output Short Circuit Characteristic V1  
Supply shall protect itself against Short Circuit conditions. The Power Supply shall recover from short circuit conditions without operator intervention.  
Output Short Circuit Characteristic V2  
www.slpower.com  
CINT3110 REV 1.1, 26-NOV-12  
8
CINT3110  
110W Triple Output  
Industrial Series  
Output Short Circuit Characteristic V3  
Output Overvoltage Characteristic V1  
Supply shall protect itself against over voltage conditions. The Power Supply shall latch and require AC input recycle to reset.  
AC input 90V 60Hz  
Output Overvoltage Characteristic V2  
www.slpower.com  
AC input 264V 50Hz  
CINT3110 REV 1.1, 26-NOV-12  
9
CINT3110  
110W Triple Output  
Industrial Series  
Output Overvoltage Characteristic V3  
Startup Time  
Start up time is <2seconds  
Hold-up Time  
Hold up time is 16mS minimum  
Power Fail Signal Timing  
Active Low TTL logic signal goes high 100 - 500 ms after main output; it goes low at least 6 mS before loss of regulation.  
Data Sheet © 2012 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for  
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.  
www.slpower.com  
CINT3110 REV 1.1, 26-NOV-12  
10  

相关型号:

CINT3110A1908K01

The CINT3110 Series are industrial grade, high efficiency, triple output power supplies in a small 2” x 4” size.
SLPOWER

CINTEL287XL

Math Coprocessor, 16-Bit, CMOS, CDIP40, CERAMIC, DIP-40
INTEL

CIOH175

INVERTER
SUMIDA

CIP2022

Piezo Element
CANOPUS

CIP2732

Piezo Element
CANOPUS

CIP3250A

Component Interface Processor
MICRONAS

CIP3250APS

Consumer Circuit, CMOS, PQCC68, PLASTIC, LCC-68
TDK

CIP3542

Piezo Element
CANOPUS

CIP3548

Piezo Element
CANOPUS

CIPS217MS5A

CMOS Image Sensor, IMAGE SENSOR-NMOS, 0.10-4.90V, RECTANGULAR
TOSHIBA

CIPS257MD5A

CMOS Image Sensor, IMAGE SENSOR-NMOS, 0.10-4.90V, RECTANGULAR
TOSHIBA

CIPS305MS5A

CMOS Image Sensor, IMAGE SENSOR-NMOS, 0.10-4.90V, RECTANGULAR
TOSHIBA