FLU1-50-1AD [SLPOWER]
OPEN-FRAME SWITCHING POWER SUPPLIES; 开架式开关电源型号: | FLU1-50-1AD |
厂家: | SL Power Electronics |
描述: | OPEN-FRAME SWITCHING POWER SUPPLIES |
文件: | 总4页 (文件大小:840K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
50-60W
OPEN-FRAME SWITCHING POWER SUPPLIES
• Single, Dual and Triple Output Models
• Models with Universal AC Input or DC Input
• CE Mark: UL/CSA/EN60950 Approvals
• Models to UL544/CSA C22.2-601/EN60-601
Medical Safety Standards
• EN55022/FCC Class B Input Line Filters
• 0% Minimum Load Requirement
• Over-Current/Short-Circuit Protection
• 2-Year Warranty
• Minimum 200,000-Hour MTBF
CHARACTERISTICS
Input Voltage ................................FLU and MDU models, universal input
voltage range 85-265 VAC single
phase or 100-370 VDC. DC-input mod-
els, see ratings table.
Input Line Frequency ...................47-440 Hz (ac input models).
Input Line Protection ....................FLU and MDU models, MOV transient
protected, input line fuse on-board.
Output Current Output
Output Voltage Min. Nom. Max. Voltage Line Load Cross-
(See Note 1.)
Model
Output (V)
(A) (A)
(A)
Tol. Reg. Reg. Reg.
EMI Filter......................................Standard (FLU and MDU models).
Performance surpasses conducted EMI
AC-DC 50W Singles
85-265 VAC Input
requirements of EN55022/FCC Class B
FLU1-50-1AD
FLU1-50-2AD
FLU1-50-3AD
FLU1-50-4AD
FLU1-50-5AD
FLU1-50-6AD
V1
V1
V1
V1
V1
V1
5
0.00 10.0 10.0 1.0% 0.5% 0.5%
0.00 5.60 5.60 1.0% 0.5% 0.5%
0.00 4.20 4.20 1.0% 0.5% 0.5%
0.00 3.33 3.33 1.0% 0.5% 0.5%
0.00 2.10 2.10 1.0% 0.5% 0.5%
0.00 1.75 1.75 1.0% 0.5% 0.5%
—
—
—
—
—
—
by 10 dB, typical.
9
Continuous Output Power............FLU1-50, MDU1-50, FLU2-50, FLU3-
50, and DC50 series, 50W, max.
12
15
24
28
FLU1-60 and DC60 series, 60W, max.
Leakage Current...........................MDU series, non-patient contact rating:
300 µA, maximum.
Output Voltage Adjust...................Primary output adjustable 5%.
Auxiliary outputs fixed.
Efficiency ......................................62-76%, typical (nominal input voltage,
nominal load conditions).
Hold-Up Time ...............................16 ms (115 VAC input), 32 ms (230
VAC input), minimum, at full load.
Overload Protection......................Power-limit circuit.
Short-Circuit Protection ................Continuous.
Over-Voltage Protection ...............FLU and MDU series, primary output
only (120% of rated output, typical).
Soft Start ......................................Standard on all ac-input models.
Design Topology...........................Flyback converter with current-mode
control.
AC-DC 50W Singles To UL544/EN60-601/CSA 22.2-601.1
MDU1-50-1AD V1
MDU1-50-2AD V1
MDU1-50-3AD V1
MDU1-50-4AD V1
MDU1-50-5AD V1
MDU1-50-6AD V1
5
0.00 10.0 10.0 1.0% 0.5% 0.5%
0.00 5.60 5.60 1.0% 0.5% 0.5%
0.00 4.20 4.20 1.0% 0.5% 0.5%
0.00 3.33 3.33 1.0% 0.5% 0.5%
0.00 2.10 2.10 1.0% 0.5% 0.5%
0.00 1.75 1.75 1.0% 0.5% 0.5%
—
—
—
—
—
—
9
12
15
24
28
AC-DC 60W Singles
85-265 VAC Input
FLU1-60-1AD
FLU1-60-2AD
FLU1-60-3AD
FLU1-60-4AD
FLU1-60-5AD
FLU1-60-6AD
V1
V1
V1
V1
V1
V1
5
0.00 12.0 12.0 1.0% 0.1% 0.2%
—
—
—
—
—
—
Frequency of Operation ...............FLU1-50 and MDU1-50 series, 40 kHz,
fixed. DC50 and DC60 series, 100
9
0.00 6.70 6.70 1.0% 0.1% 0.2%
0.00 5.00 5.00 1.0% 0.1% 0.2%
0.00 4.00 4.00 1.0% 0.1% 0.2%
0.00 2.50 2.50 1.0% 0.1% 0.2%
0.00 2.10 2.10 1.0% 0.1% 0.2%
kHz, fixed. FLU1-60, FLU2-50, FLU3-
50 series, 33 kHz, fixed.
12
15
24
28
Hi-Pot Isolation.............................FLU Series: 5300 VDC, input-to-output
for one minute.
MDU Series: 5700 VDC, input-to-output
for one minute.
DC50 and DC60 Series, 2500 VDC
AC-DC 50W Duals
85-265 VAC Input
input-to-output for one minute. (See
FLU2-50-1AD
V1
+5
0.00 5.00 6.00 1.0% 0.2% 1.0%
—
Note 2.)
*
V2 +12 0.00 2.10 3.00 5.0% 1.0% 3.0% 5.0%
Noise, Ripple and Spike...............FLU and MDU models, 1% peak-to-
peak, maximum. (See Notes 4, 5.)
FLU2-50-2AD
V1 +5 0.00 5.00 6.00 1.0% 0.2% 1.0%
—
Temperature Range......................-20°C to +70°C.
Output Power De-Rating..............De-rate output power and current lin-
early 2%/°C from +50°C to +70°C.
Temperature Coefficient ............... 0.05%/°C over the entire operating
temperature range.
V2 +24 0.00 1.10 1.50† 5.0% 1.0% 3.0% 5.0%
* Peak output current rating = 5.0A (<60 seconds, duty cycle <10%).
† Peak output current rating = 2.5A (<60 seconds, duty cycle <10%).
Relative Humidity .........................0 to 95%, non-condensing.
Altitude .........................................0 to 10,000 feet.
Cooling .........................................Convection cooling is adequate.
Moving air is recommended for opera-
Optional L-bracket enclosures for the FLU1-50
series are available. For details, see dimension
drawings for the Power General 40W series.
tion in a confined area.
Storage Temperature....................-40°C to +85°C.
Storage Humidity..........................0 to 95%, non-condensing.
Mean Time Between Failures.......>200,000 hours. (Note 6.)
POWER GENERAL 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com
12
50-60W
OPEN-FRAME SWITCHING POWER SUPPLIES
Output Current Output
Output Voltage Min. Nom. Max. Voltage Line Load Cross-
Input Voltage Output
Min.Nom.Max. Voltage
(V) (V) (V) Output (V)
Output Current Output
Min. Nom. Max. Voltage Line Load
Model
Output (V)
(A) (A)
(A)
Tol. Reg. Reg. Reg.
Model
(A) (A) (A)
Tol. Reg. Reg.
AC-DC 50W Triples
85-265 VAC Input
DC-DC 50W Triples§
V1
+5
0.00 5.00 6.00 1.0% 0.2% 1.0%
—
V1 5(ISO) 0.5 3.00 6.00 5.0% 0.2% 0.2%
V2 12(ISO) 0.1 1.00 1.00 4.0% 0.2% 0.2%
V3 12(ISO) 0.1 1.00 1.00 4.0% 0.2% 0.2%
*
FLU3-50-1AD
V2 +12 0.00 1.60 3.00 5.0% 1.0% 2.0% 5.0%
V3 - 12 0.00 0.50 0.50 5.0% 2.0% 3.0% 5.0%
DC50-1A 10 12 18
DC50-2A 10 12 18
DC50-3A 10 12 18
DC50-4A 10 12 18
DC50-1B 18 24 36
DC50-2B 18 24 36
DC50-3B 18 24 36
DC50-4B 18 24 36
DC50-1C 36 48 72
DC50-2C 36 48 72
DC50-3C 36 48 72
DC50-4C 36 48 72
V1 12(ISO) 0.5 3.00 6.00 5.0% 0.2% 0.2%
V2 15(ISO) 0.1 1.00 1.00 4.0% 0.2% 0.2%
V3 15(ISO) 0.1 1.00 1.00 4.0% 0.2% 0.2%
V1 +5 0.00 5.00 6.00 1.0% 0.2% 1.0%
—
*
FLU3-50-2AD
V2 +12 0.00 1.80 3.00 5.0% 1.0% 3.0% 5.0%
V3
V1
- 5
+5
0.00 0.50 0.50 3.0% 0.5% 1.0% 1.0%
V1 5(ISO) 0.5 3.00 6.00 5.0% 0.2% 0.2%
V2 12(ISO) 0.2 2.00 3.00 4.0% 0.4% 6.0%
V3 12(ISO) 0.1 0.30 0.50 4.0% 0.4% 6.0%
0.00 5.00 6.00 1.0% 0.2% 1.0%
—
*
FLU3-50-3AD
FLU3-50-4AD
V2 +15 0.00 1.15 2.00 5.0% 1.0% 3.0% 5.0%
V3 -15 0.00 0.50 0.50 3.0% 0.5% 1.0% 1.0%
V1 5(ISO) 0.00 8.00 9.00 1.0% 0.2% 0.5%
V2 12(ISO) 0.00 0.40 0.60 3.0% 0.5% 1.0% 1.0%
V3 12(ISO) 0.00 0.40 0.60 3.0% 0.5% 1.0% 1.0%
V1 5(ISO) 0.5 3.00 6.00 5.0% 0.2% 0.2%
V2 12(ISO) 0.2 2.00 3.00 4.0% 0.2% 6.0%
V3 5(ISO) 0.2 0.50 1.00 4.0% 0.2% 6.0%
—
)
V1 5(ISO) 0.5 3.00 6.00 5.0% 0.2% 0.2%
V2 12(ISO) 0.1 1.00 1.00 4.0% 0.2% 0.2%
V3 12(ISO) 0.1 1.00 1.00 4.0% 0.2% 0.2%
V1 5(ISO) 0.00 8.00 9.00 1.0% 0.2% 0.5%
—
FLU3-50-5AD
V2 15(ISO) 0.00 0.35 0.60 3.0% 0.5% 1.0% 1.0%
V3 15(ISO) 0.00 0.35 0.60 3.0% 0.5% 1.0% 1.0%
V1 5(ISO) 0.5 3.00 6.00 5.0% 0.2% 0.2%
V2 15(ISO) 0.1 1.00 1.00 4.0% 0.2% 0.2%
V3 15(ISO) 0.1 1.00 1.00 4.0% 0.2% 0.2%
* Peak output current rating = 5.0A (<60 seconds, duty cycle <10%).
Notes
V1 5(ISO) 0.5 3.00 6.00 5.0% 0.2% 0.2%
V2 12(ISO) 0.2 2.00 3.00 4.0% 0.4% 6.0%
V3 12(ISO) 0.1 0.30 0.50 4.0% 0.4% 6.0%
1. For FLU and MDU models, replace the input line fuse with the same type
and rating. Recommended: 2A/250V slow-blow fuse.
V1 5(ISO) 0.5 3.00 6.00 5.0% 0.2% 0.2%
V2 12(ISO) 0.2 2.00 3.00 4.0% 0.2% 6.0%
V3 5(ISO) 0.2 0.50 1.00 4.0% 0.2% 6.0%
For the DC50 series, an external input line fuse is recommended: For
12V input models, use a 10A/125V fuse; for 24V input, use a 5A/125V
fuse; for 48V input models, use a 3A/125V fuse.
For the DC60 series, an external input line fuse is recommended: For
12V input models, use a 10A/125V fuse; for 24V input, use a 6A/125V
fuse; for 48V input models, use a 4A/125V fuse.
V1 5(ISO) 0.5 3.00 6.00 5.0% 0.2% 0.2%
V2 12(ISO) 0.1 1.00 1.00 4.0% 0.2% 0.2%
V3 12(ISO) 0.1 1.00 1.00 4.0% 0.2% 0.2%
2. Hi-pot isolation is 2200 VDC from the input of the supply to ground for 60
seconds.
V1 5(ISO) 0.5 3.00 6.00 5.0% 0.2% 0.2%
V2 15(ISO) 0.1 1.00 1.00 4.0% 0.2% 0.2%
V3 15(ISO) 0.1 1.00 1.00 4.0% 0.2% 0.2%
3. All measurements are made directly at the terminals of the power supply.
4. Peak-to-peak and RMS metering equipment must have a 20 MHz fre-
quency response with probes and cables that maintain a frequency
response of 20 Hz to 20 MHz. Output ripple and spikes are measured
directly at the output terminals of the power supply with a 0.1 µF ceramic
capacitor. The instruments’ probe ground band must make direct contact
with the output return or common terminal of the supply to prevent erro-
neous noise measurements.
V1 5(ISO) 0.5 3.00 6.00 5.0% 0.2% 0.2%
V2 12(ISO) 0.2 2.00 3.00 4.0% 0.4% 6.0%
V3 12(ISO) 0.1 0.30 0.50 4.0% 0.4% 6.0%
V1 5(ISO) 0.5 3.00 6.00 5.0% 0.2% 0.2%
V2 12(ISO) 0.2 2.00 3.00 4.0% 0.2% 6.0%
V3 5(ISO) 0.2 0.50 1.00 4.0% 0.2% 6.0%
5. For DC50-1 and DC50-2 models, 100 kHz noise and ripple at the 5V out-
put is 20 mVpp, typical; at auxiliary outputs, it is 5 mVpp, typical. For
DC50-3 and DC50-4 models, 100 kHz noise and ripple is 20 mVpp, typi-
cal, for all outputs.
For DC60 models, 100 kHz noise and ripple is typically 20 mVpp.
6. MTBF is calculated using the parts stress method in MIL-HDBK 217F
(ground benign, TA = +25°C).
DC-DC 50-72W Singles§
DC60-1A 10 12 18
DC60-2A 10 12 18
DC60-3A 10 12 18
DC60-4A 10 12 18
V1
V1
V1
V1
5
0.0 10 10 5.0% 0.2% 0.2%
0.0 5.0 5.0 5.0% 0.2% 0.2%
0.0 4.0 4.0 5.0% 0.2% 0.2%
0.0 2.5 2.5 5.0% 0.2% 0.2%
12
15
24
7. Output voltage tolerance is measured under nominal load conditions.
8. Line regulation is measured under nominal load conditions as the input
voltage is varied from 85 to 265 VAC (ac-input models) or from minimum
to maximum input voltage (dc input models).
DC60-1B 18 24 36
DC60-2B 18 24 36
DC60-3B 18 24 36
DC60-4B 18 24 36
V1
V1
V1
V1
5
0.0 12 12 5.0% 0.2% 0.2%
0.0 5.0 6.0 5.0% 0.2% 0.2%
0.0 4.0 4.8 5.0% 0.2% 0.2%
0.0 2.5 3.0 5.0% 0.2% 0.2%
12
15
24
9. Load regulation is measured at 115 VAC or 230 VAC (ac input models) or
at nominal input voltage (dc input models) . For single output models,
load regulation is measured while output current is varied from 0% to
100% of full load. With ac-input, multiple output models, the output under
test is brought to 60% of nominal load; load current is then varied +40%/-
30% of nominal while other outputs are held at nominal load conditions.
With dc-input models, load regulation on an output is measured from
nominal to maximum and minimum load while other outputs are held at
nominal load conditions.
DC60-1C 36 48 72
DC60-2C 36 48 72
DC60-3C 36 48 72
DC60-4C 36 48 72
V1
V1
V1
V1
5
0.0 12 12 5.0% 0.2% 0.2%
0.0 5.0 6.0 5.0% 0.2% 0.2%
0.0 4.0 4.8 5.0% 0.2% 0.2%
0.0 2.5 3.0 5.0% 0.2% 0.2%
12
15
24
§ DC50 and DC60 models include under-voltage shutdown (10% below loW
line, remote shutdown (TTL HIGH disables the unit), and external frequency
synchronization (2.8V positive pulse >9.1 µs at the synch pin).
10. Cross-regulation is tested by changing the load on the primary output
from 50% to 100% of nominal load while measuring the voltage change
on the auxiliary output under test.
11. The FLU1-50, FLU2-50, FLU3-50 and FLU1-60 series are approved to
UL1950 (File E140439), CSA22.2 No.234 (File LR52335) and
EN60950/IEC950/DIN VDE 0805 (TÜV Licenses R9271543, R9171470,
and R9271468).
POWER GENERAL 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com
13
50-60W
OPEN-FRAME SWITCHING POWER SUPPLIES
FLU1-50 AND MDU1-50 SERIES
A. Dimensions shown are in inches.
B. Tolerances = 0.00 0.01 inch.
0.000 0.005 inch.
C. P1 input connectors are Molex 26-60-4030. The mating connector
combines Molex housing 43061-0003 and crimp terminal 08-70-1030.
D. P2 output connectors are Molex 26-60-4060. The mating connector
combines Molex housing 43061-0006 and crimp terminal 08-70-1030.
Pin-Out
Pin
FLU1-50
MDU1-50
1
2
3
4
5
6
V1
V1
V1
Return
Return
Return
V1
V1
V1
Return
Return
Return
DC50 SERIES
A. Dimensions shown are in inches.
B. Tolerances = 0.00 0.01 inch.
0.000 0.005 inch.
C. P1 input connectors are Molex 26-60-4080. The mating
connector combines Molex housing 09-50-8081 and
crimp terminal 03-50-0106.
D. P2 output connectors are Molex 26-60-4100. The mat-
ing connector combines Molex housing 09-50-8101 and
crimp terminal 03-50-0106.
E. Under-voltage shutdown on the DC50 series is activated
at 10% below low line, typical. Over-voltage shutdown is
typically activated at 10% above high line.
F. A TTL HIGH signal at the external shutdown pin of the
DC50 series disables the unit.
G. External frequency synchronization of the DC50 series
requires a 2.8V positive pulse (>9.1 µs) at the external
synch pin.
Pin-Out
Pin
DC50
1
2
3
V3
V3 Return
V2
4
V2
5
6
7
V2 Return
V2 Return
V1
8
V1
9
10
V1 Return
V1 Return
POWER GENERAL 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com
14
50-60W
OPEN-FRAME SWITCHING POWER SUPPLIES
FLU2-50/FLU3-50/FLU1-60 SERIES
A. Dimensions shown are in inches.
B. Tolerances = 0.00 0.01 inch.
0.000 0.005 inch.
C. P1 input connectors are Molex 26-60-4030. The mating connector
combines Molex housing 43061-0003 and crimp terminal 08-70-1030.
D. P2 output connectors:
FLU1-60 series—Molex 26-60-4080
FLU2-50 series—Molex 26-60-4060
FLU3-50 series, Models 1, 2, 3—Molex 26-60-4060
FLU3-50 series, Models 4, 5—Molex 26-60-4100
Mating connector housings:
FLU1-60 series—Molex 43061-0008.
FLU2-50 series—Molex 43061-0006.
FLU3-50 series, models 1, 2, 3—Molex 43061-0006.
FLU3-50 series, models 4, 5—Molex 43061-0010.
Crimp terminals:
All models—Molex 08-70-1030.
Pin-Out
FLU3-50
FLU3-50
Pin
FLU2-50 Models 1-3 Models 4-5 FLU1-60
1
2
3
4
5
6
7
8
9
V2
V1
V2
V1
V1
+V2(ISO) +Sense§
- V2(ISO)
+V1(ISO)
+V1(ISO)
+V1(ISO)
- V1(ISO)
- V1(ISO)
- V1(ISO)
- V3(ISO)
+V3(ISO)
V1
V1
V1
Common
Common
N/C
Common
Common
V3
V1
Return
Return
Return
-Sense§
N/A
N/A
N/A
N/A
N/A
N/A
N/A
10
N/A
N/A
N/A
§
If sense terminals are not used, tie together Pins 1 and 2 and tie
together Pins 7 and 8.
DC60 SERIES
A. Dimensions shown are in inches.
B. Tolerances = 0.00 0.01 inch.
0.000 0.005 inch.
C. Under-voltage shutdown on the DC60 series is activated
at 10% below low line, typical. Over-voltage shutdown is
typically activated at 10% above high line.
D. A TTL HIGH signal at the external shutdown pin of the
DC60 series disables the unit.
E. External frequency synchronization of the DC60 series
requires a 2.8V positive pulse (>9.1 µs) at the external
synch pin.
Pin-Out
Terminal
DC60
1
2
3
4
5
6
+Sense§
V1
V1
Return
Return
-Sense§
§
If Sense terminals are not used, tie
together Terminals 1 and 2 and tie
together Terminals 5 and 6.
POWER GENERAL 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com
15