FEATURES:  
• Cost-effective power source  
• Universal input 90-264Vac  
• 2-year warranty  
• Compact (4.25" x 2.50" x 1.15"; meets 1U applications)  
• Overload and overvoltage protection  
• Built-in EMI filter  
• Commercial UL, CSA and IEC approvals  
• Medical UL2601, CSA22.2 No. 601, IEC601-1, ENB60601  
marked to LVD  
SPECIFICATIONS:  
Environmental  
AC Input  
Designed for 0 to 50°C operation at full rated output power; derate  
output current and total output power by 2.5% per °C above 50°C.  
See Environmental and Packaging Specifications on next page.  
90-264 Vac, 47-63 Hz single phase.  
Input Current  
Maximum input current at 120 Vac, 60 Hz with full rated output load:  
1.5 A  
Output Noise  
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode.  
Measured with noise probe directly across output terminals of the  
power supply.  
Hold-Up Time  
15 ms minimum from loss of ac input at full load, nominal line (115  
Vac).  
Transient Response  
500 µs typical response time for return to within 0.5% of final value  
for a 50% load step change. i/t<0.2 A/µs. Maximum voltage  
deviation is 3.5%. Startup/shutdown overshoot less than 3%.  
Output Power  
50 W continuous, 60 W peak. Peak ratings are for 60 s maximum  
duration, 10% duty cycle. During peak load condition, output  
regulation may exceed total regulation limits.  
Voltage Adjustment  
Built-in potentiometer adjusts V1 ±5%.  
Overload Protection  
Fully protected against short circuit and output overload. Short  
circuit protection is cycling type power limit on outputs 1 & 2;  
foldback type on output 3. Recovery after fault is automatic. See  
output ratings chart for additional notes or conditions.  
Overload Protection  
Factory set to begin power limiting at 60 W.  
EMI/EMC Compliance  
All models include built-in EMI filtering to meet the following  
emissions requirements:  
Efficiency  
70-85% at full rated load, nominal input voltage, depending on  
model and load distribution.  
EMISPECIFICATIONS  
ConductedEmissions  
Conducted Emissions Medical  
Static Discharge  
RF Field Susceptibility  
Fast Transients/Bursts  
Surge Susceptibility  
COMPLIANCELEVEL  
EN55022 Class B; FCC Class B  
EN55011 Class B; FCC Class B  
EN61000-4-2, 6 kV contact, 8 kV air  
EN61000-4-3, 3V/meter  
Minimum Load  
Operating without minimum load will not degrade reliability, but  
regulation may be affected. Multiple output models require 20%  
minimum load on V1 for proper regulation. Single models require  
5% minimum load.  
EN61000-4-4, 2 kV, 5 kHz  
EN61000-4-5, 1 kV diff., 2 kV com.  
Commercial Leakage Current  
160 µA 254 Vac @ 60 Hz input (with no deviations).  
Turn-on Time  
Less than 1 second at 120 Vac, 25°C (inversely proportional to input  
voltage and thermistor temperature).  
Commercial Safety  
All GLC models are approved to UL1950, CSA22.2 No. 234 Level  
3, IEC950 and EN60950. Consult factory for approval status.  
Input Protection  
Internal ac fuse provided. Designed to blow only if a catastrophic  
failure occurs in the unit—fuse does not blow on overload or short  
circuit.  
Medical Leakage Current  
100 µA 264 Vac @ 60 Hz input (normal conditions).  
Inrush Current  
Medical Safety  
Inrush is limited by internal thermistors. Inrush at 240 Vac, averaged  
over the first ac half-cycle under cold start conditions will not exceed  
37 A.  
All GLM models are approved to UL2601, CSA22.2 No. 601,  
IEC601-1 and EN60601. Consult factory for approval status.  
Temperature Coefficient  
0.03%/ºC typical on all outputs.  
Condor D.C. Power Supplies, Inc./A subsidiary of SL Industries, Inc.  
2311 Statham Parkway, Oxnard, CA 93033 • 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com  
52  
GLC50 Commercia/GLM50 Medical 50Watt Multiple Output  
Commercial  
Model  
Medical  
Model  
Total  
Regulation (A)  
Output No.  
Output  
Current  
Minimum Load  
0.8 A  
OVP Setpoint  
6.2 ± 0.6 V  
Noise P-P  
GLC50A  
GLC50B  
GLC50D  
GLC50G  
GLM50A  
GLM50B  
GLM50D  
GLM50G  
1
2
3
+5.05 V  
+12 V  
-12 V  
4 A  
2.5 A  
0.2 A  
50 mV  
120 mV  
120 mV  
2%  
+10%, -5%  
3%  
1
2
3
+ 5.1 V  
+15 V  
-15 V  
4 A  
2.5 A  
0.2 A  
0.8 A  
0.8 A  
0.8 A  
6.2 ± 0.6 V  
6.2 ± 0.6 V  
4.2 ± 0.6 V  
50 mV  
150 mV  
150 mV  
2%  
+10%, -5%  
3%  
1
2
3
+5.1 V  
+24 V  
-12 V  
4 A  
1.5 A  
0.2 A  
50 mV  
240 mV  
120 mV  
2%  
+10%, -5%  
3%  
1
2
3
+3.3 V  
+12 V  
-12 V  
4 A  
2.5 A  
0.2 A  
33 mV  
120 mV  
120 mV  
2%  
+10%, -5%  
3%  
GLC50-3.3  
GLC50-5  
GLM50-3.3  
GLM50-5  
1
1
1
1
1
1
1
3.3 V  
5.1 V  
12 V  
15 V  
24 V  
28 V  
48 V  
8 A  
0
0
0
0
0
0
0
4.2 ± 0.6 V  
6.2 ± 0.6 V  
14 ± 1.1 V  
18.5 ± 1.5 V  
28 ± 2.5 V  
34.5 ± 2.8 V  
54 ± 3.0 V  
33 mV  
50 mV  
2%  
2%  
2%  
2%  
2%  
2%  
2%  
8 A  
GLC50-12  
GLC50-15  
GLC50-24  
GLC50-28  
GLC50-48  
GLM50-12  
GLM50-15  
GLM50-24  
GLM50-28  
GLM50-48  
4.2 A  
3.3 A  
2.1 A  
1.8 A  
1.1 A  
120 mV  
150 mV  
240 mV  
280 mV  
480 mV  
A. Totalregulationisdefinedasthemaximumdeviationfromthenominalvoltageforallsteady-stateconditionsofinitialvoltagesetting, inputlinevoltageandoutputload.  
GLC50/GLM50 MECHANICAL SPECIFICATIONS  
4.25 [107.95mm]  
INPUT J1:  
AMP P/N 640445-3, 0.156 CTR 0.045  
SQUARE PIN HEADER  
4.00 [101.60mm]  
0.125  
[3.18mm]  
PIN 3) AC NEUTRAL  
PIN 2) NO PIN  
PIN 1) AC LINE  
A2  
OUTPUT J2:  
AMP P/N 640445-6, 0.156 CTR 0.045  
SQUARE PIN HEADER  
2.50  
[63.50mm]  
J1  
MULTIPLE OUTPUT  
PIN 1) OUTPUT #2  
PIN 2) OUTPUT #1  
PIN 3) OUTPUT #1  
PIN 4) COMMON  
PIN 5) COMMON  
PIN 6) OUTPUT #3  
SINGLE OUTPUT  
PIN 1-3) OUTPUT  
PIN 4-6) RETURN  
T2  
2.25  
[57.15mm]  
F1  
C4  
MATING CONNECTORS: AMP P/N  
HOUSING  
INPUT  
OUTPUT  
644329-3  
644329-6  
0.125  
[3.18mm]  
NOTE: 5A MAXIMUM RECOMMENDED  
CURRENT PER CONNECTOR PIN  
1.25" [31.75mm]  
MOUNTING HOLE  
WEIGHT: 5 OZ. [0.142 KG]  
0.138 TYP.  
[3.51mm]  
TOLERANCES: X.XX=0.030 [0.76mm]  
X.XXX=0.010 [0.25mm]  
MAX. LEAD PROTRUSION 0.10" [2.54mm]  
MAX. COMPONENT HEIGHT 1.15" [29.21mm]  
Environmental  
Operating  
Non-operating  
Specification  
Temperature (A)  
Humidity (A)  
Shock (B)  
See individual specs  
0 to 95% RH  
-40 to +85ºC  
0 to 95% RH  
40 gpk  
A. Units should be allowed to warm up/operate under non-condensing conditions  
before application of power.  
B. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3  
orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.  
C. Shock testinghalf-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,  
total 6 shocks.  
20 gpk  
Altitude  
-500 to 10,000 ft  
1.5 grms, 0.003 g2/Hz  
-500 to 40,000 ft  
5 grms, 0.026 g2/Hz  
Vibration (C)  
Condor D.C. Power Supplies, Inc./A subsidiary of SL Industries, Inc.  
2311 Statham Parkway, Oxnard, CA 93033 • 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com  
53  

相关型号:

GLC50-5

AC-DC Regulated Power Supply Module, 50W
SLPOWER

GLC50A

50 WATT GLOBAL PERFORMANCE SWITCHERS
SLPOWER

GLC50AG

GLC50 Commercial/GLM50 Medical
ETC

GLC50B

50 WATT GLOBAL PERFORMANCE SWITCHERS
SLPOWER

GLC50D

INSTALLATION INSTRUCTIONS GLC50 MULTI OUTPUT SERIES
SLPOWER

GLC50G

50 WATT GLOBAL PERFORMANCE SWITCHERS
SLPOWER

GLC555

Analog Timer Circuit
ETC

GLC556

Analog Timer Circuit
ETC

GLC560(DIP)

GAME SUPPORT|CMOS|DIP|20PIN
ETC

GLC560(SOP)

GAME SUPPORT|CMOS|SOP|20PIN
ETC

GLC56010

SURFCOIL SMT INDUCTORS
ETC

GLC65

65 Watt Single Output Global Performance Switchers
SLPOWER