FEATURES:  
• Wide-range AC input 85-264VAC  
• 2-year warranty  
• Approved to UL1950, IEC950, EN60950 and CSA22.2-  
234 L3  
• Exceeds FCC and CISPR22 Class B conducted  
emissions requirements  
• Multiple outputs  
• For medical version, see p. 92  
marked to LVD  
No-Load Turn-on/Standby  
No degradation of reliability will occur.  
SPECIFICATIONS:  
AC Input  
85-264Vac, 47-63Hz single phase.  
Output Noise  
0.5% RMS, 1% Pk-Pk, 20MHz bandwidth, differential mode. Measured  
with noise probe directly across output terminals of the power supply.  
Transient Response  
Input Current  
Maximum input current at 120Vac, 60Hz with full rated output load: 3.5A  
Main output—500µSec typical response time for return to within 0.5% of  
final value for a 50% load step change. i/t<0.2A/µSec. Maximum  
voltage deviation is 3.5%. Startup/shutdown overshoot less than 3%.  
Hold-Up Time  
20mSec minimum from loss of AC input at full load, nominal line (115Vac).  
Output Power  
Remote Sense  
Provided as a standard feature on output 1.  
Voltage Adjustment  
Built-in potentiometer adjusts voltage ±5% on outputs 1 & 2.  
100W continuous, 165W peak; 130 with 26 cfm air flow. Peak ratings are  
for 60 sec. maximum duration, 10% duty cycle. During peak load  
condition, output regulation may exceed total regulation limits.  
Overload Protection  
Reverse Voltage Protection  
All outputs protected against inadvertent application of reverse voltage up  
to 1 times rated current of the reverse output.  
Fully protected against short circuit and output overload. Short circuit  
protection is cycling type power limit on outputs 1 & 2; foldback type on  
outputs 3 & 4. Recovery after fault is automatic. See output ratings chart  
for additional notes or conditions.  
Overload Protection  
Overvoltage Protection  
Factory set to begin power limiting at approximately 170W.  
Main outputs: 124% ± 12% typical.  
EMI/EMC Compliance  
All models include built-in EMI filtering to meet the following emissions  
requirements:  
Efficiency  
70% at full rated load, nominal input voltage, depending on model and  
load distribution.  
Turn-on Time  
Less than 1 second at 120VAC, 25°C (inversely proportional to input  
voltage and thermistor temperature).  
EMI SPECIFICATIONS  
Conducted Emissions  
Static Discharge  
RF Field Susceptibility  
Fast Transients/Bursts  
Surge Susceptibility  
COMPLIANCE LEVEL  
EN55022 Class B; FCC Class B  
EN61000-4-2, 6 kV contact, 8 kV air  
EN61000-4-3, 3 V/meter  
EN61000-4-4, 2 kV, 5 kHz  
EN61000-4-5, 1 kV diff., 2 kV com.  
Input Protection  
Internal AC fuse provided. Designed to blow only if a catastrophic failure  
occurs in the unit.  
Leakage Current  
0.7mA. 254Vac @ 60Hz input.  
Inrush Current  
Inrush is limited by internal thermistors. Inrush at 240VAC under cold start  
conditions will not exceed 34A.  
Safety  
Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and EN60950.  
UL file #E135803 commercial; CSA #LR46516 all models. The output(s)  
are intended for safety earthed Signal Output and Intermediate Circuits  
only. All DC outputs are SELV under normal and single fault conditions.  
Temperature Coefficient  
0.03%/ºC typical on all outputs.  
Environmental  
Designed for 0 to 50°C operation at full rated output power; derate  
output current and total output power by 2.5% per °C above 50°C. See  
Environmental and Packaging Specifications (p. 11) for additional  
information.  
Power Fail  
TTL- or CMOS-compatible output goes low (< 0.5V) 5mSec before  
output voltage drops more than 4% below nominal voltage upon loss of  
AC power. The signal is factory set to trip on 84 to 94VAC brown-out  
depending upon incoming line impedance and distortion. Other settings  
are available to the user through adjustment of built-in potentiometer  
(consult factory for assistance).  
Condor D.C. Power Supplies, Inc./A subsidiary of SL Industries, Inc.  
2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 • www.condorpower.com/  
26  
Output  
Output  
Output  
Total  
Model  
Output No.  
Output  
Minimum  
Maximum (B)  
Maximum (C) Output Peak  
Noise P-P  
Regulation (A)  
GPC130A  
1
2
3
4
+5V  
+12V  
-12V  
+12V  
3A  
0A  
0A  
0A  
16A  
5A  
1.2A  
1.2A  
20A  
5A  
1.2A  
1.2A  
25A  
8A  
1.5A  
1.5A  
50mV  
120mV  
120mV  
120mV  
2%  
2%  
3%  
3%  
GPC130B  
GPC130C  
GPC130D  
GPC130E  
1
2
3
4
+ 5V  
+12V  
-5V  
3A  
0A  
0A  
0A  
16A  
5A  
1.2A  
1.2A  
20A  
5A  
1.2A  
1.2A  
25A  
8A  
1.5A  
1.5A  
50mV  
120mV  
50mV  
2%  
2%  
3%  
3%  
-12V  
120mV  
1
2
3
4
+5V  
+12V  
-15V  
+15V  
3A  
0A  
0A  
0A  
16A  
5A  
1.2A  
1.2A  
20A  
5A  
1.2A  
1.2A  
25A  
8A  
1.5A  
1.5A  
50mV  
120mV  
150mV  
150mV  
2%  
2%  
3%  
3%  
1
2
3
4
+5V  
+24V  
-12V  
+12V  
3A  
0A  
0A  
0A  
16A  
3.5A  
1.2A  
1.2A  
20A  
3.5A  
1.2A  
1.2A  
25A  
5A  
1.5A  
1.5A  
50mV  
240mV  
120mV  
120mV  
2%  
2%  
3%  
3%  
1
2
3
4
+5V  
+24V  
-15V  
+15V  
3A  
0A  
0A  
0A  
16A  
3.5A  
1.2A  
1.2A  
20A  
3.5A  
1.2A  
1.2A  
25A  
5A  
1.5A  
1.5A  
50mV  
240mV  
150mV  
150mV  
2%  
2%  
3%  
3%  
A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.  
B. Unrestricted natural convection cooling.  
C. Requires 26cfm moving air.  
GPC130 MECHANICAL SPECIFICATIONS:  
8.50 [215.90mm]  
8.000 [203.20mm]  
INPUT:  
J1: AMP P.C.B. HEADER P/N 640445-5  
PIN 1)  
PIN 2)  
PIN 3)  
AC LINE  
N/C  
AC NEUTRAL  
N/C  
AC GROUND  
PIN 4)  
PIN 5)  
3
1
5
TB2  
1.278 ± 0.20  
MATING CONNECTOR AMP P/N  
[32.46 ± 0.51]  
J1  
1
J3  
1
OUT 2  
V.ADJ  
TB1: 0.375 X 6-32 TERMINAL BLOCK  
HOUSING 640250-5  
CONTACTS 770522-1  
1
TB1  
16  
PIN 1)  
PIN 2)  
PIN 3)  
AC LINE  
AC NEUTRAL  
AC GROUND  
1
F1  
1.944  
[49.38mm]  
SIGNALS:J2 AMP P.C.B. HEADER P/N 640456-4  
PIN 1)  
PIN 2)  
PIN 3)  
PIN 4)  
N/C  
+ SENSE  
- SENSE  
POWER FAIL  
4.50  
8
9
[114.30mm]  
T3  
16  
MATING CONNECTOR AMP P/N 640440-4  
OUT1  
V.ADJ  
J2  
1
4
OUTPUT:  
6-32 MTG  
AMP P.C.B. HEADER P/N 1-640445-6  
J3:  
(0.125 [3.18mm] MAX SCREW PENETRATION)  
4 PLCS  
PF ADJ  
PIN 1)  
PIN 2)  
PIN 3)  
PIN 4)  
PIN 5)  
PIN 6)  
PIN 7)  
PIN 8)  
OUTPUT #4  
OUTPUT #4  
OUTPUT #3  
OUTPUT #3  
OUTPUT #2  
OUTPUT #2  
COMMON  
PIN 9)  
PIN 10)  
PIN 11)  
PIN 12)  
PIN 13)  
PIN 14)  
PIN 15)  
PIN 16)  
COMMON  
COMMON  
COMMON  
COMMON  
OUTPUT #1  
OUTPUT #1  
OUTPUT #1  
OUTPUT #1  
0.25  
[6.35mm]  
0.12 [3.05mm]  
6-32 MTG  
4 PLCS  
COMMON  
XFMR (T3) PROTRUDES  
IN THIS AREA ONLY.  
2.00  
[50.80mm]  
MATING CONNECTOR AMP P/N  
HOUSING 1-640250-6  
CONTACTS 770522-1  
1.278 ± 0.20  
[32.46 ± 0.51]  
TB2: 0.375 X 6-32 TERMINAL BLOCK  
PIN 1)  
PIN 2)  
PIN 3)  
PIN 4)  
OUTPUT #4  
OUTPUT #3  
OUTPUT #2  
COMMON  
PIN 5)  
PIN 6)  
PIN 7)  
PIN 8)  
COMMON  
COMMON  
OUTPUT #1  
OUTPUT #1  
OPTIONAL COVER AVAILABLE, ORDER P/N 08-30466-1130  
OPTION: ADD "-T" SUFFIX TO PART NUMBER FOR  
6-32 SCREW TERMINAL BLOCK ON I/O  
WEIGHT: 2.3 LBS MAX. [1.05 kg]  
TOLERANCES: X.XX=0.030 [0.76mm]  
X.XXX=0.010 [0.25mm]  
Condor D.C. Power Supplies, Inc./A subsidiary of SL Industries, Inc.  
2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911  
www.condorpower.com/  
27  

相关型号:

GPC130A4

Power Supply Module
SLPOWER

GPC130B

AC-DC Regulated Power Supply Module, 130W
SLPOWER

GPC130B1

Power Supply Module
SLPOWER

GPC130B4

Power Supply Module
SLPOWER

GPC130BG

AC-DC Regulated Power Supply Module, 130W
SLPOWER

GPC130C

AC-DC Regulated Power Supply Module, 130W
SLPOWER

GPC130C1

Power Supply Module
SLPOWER

GPC130C2

Power Supply Module
SLPOWER

GPC130C3

Power Supply Module
SLPOWER

GPC130CG

AC-DC Regulated Power Supply Module, 130W
SLPOWER

GPC130D

AC-DC Regulated Power Supply Module, 130W
SLPOWER

GPC130D1

Power Supply Module
SLPOWER