ME60A4803Q01 [SLPOWER]
60W Single Output External Power;型号: | ME60A4803Q01 |
厂家: | SL Power Electronics |
描述: | 60W Single Output External Power |
文件: | 总4页 (文件大小:707K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
ME60
60W Single Output External Power
Medical Series
Features
.
Meets UL/EN/IEC60601-1-2, 4th edition for
EMC*
.
.
Approved to EN/IEC/UL60601-1, 3rd edition
with isolation levels which satisfy the 2 MOPP
requirements
Meets DoE Efficiency Level VI Requirements
.
.
No load input power
Average Efficiency
.
.
.
.
Up to 60W of AC-DC Power
Universal Input 90-264Vac Input Range
Desktop Style Package
Meets EN55011/CISPR11, FCC Part 15.109
Class B Conducted & Radiated Emissions, with
6db margin
.
.
.
E-cap life of >7 years
3 Year Warranty
IP22 Rated Enclosure
Description
A high performance AC to DC external power supply family designed for medical applications. The ME60A Medical Series low
power external AC-DC power supplies are approved to safety EN/IEC/UL60601-1, 3rd edition and EN/IEC/UL60601-1-11:2010
for Home Healthcare (non-hospital use) applications with and isolation levels which satisfy the 2 MOPP requirements and
designed to UL/EN/IEC60601-1-2, 4th edition for EMC*. The ME60A Series models will operate at universal input range of 90 to
264Vac over the wide temperature range of -20°C to +50°C, delivering full rated output power up to +40°C and applicable
output power derating at 50°C. These models are available in desktop versions, include an IP22 rating per IEC60529 for the
enclosure, and the output cable can be terminated at a variety of output connectors.
*Consult Factory for Table 9 compliance information.
Model Selection
Model
Number
Output
Current
7.00A
Output
Power
35W
Ripple &
Noise¹
75mV pk-pk
Line
Regulation
±1%
Load
Regulation
±5%
Output
Connector
6 pin Molex Type2
Input
Configuration
Volts
5.0V
ME60A0551F01
ME60A1203F01
ME60A1503F01
ME60A1803F01
ME60A2403F01
ME60A4803F01
ME60A0551N01
ME60A1203N01
ME60A1503N01
ME60A1803N01
ME60A2403N01
ME60A4803N01
ME60A0551Q01
ME60A1203Q01
ME60A1503Q01
ME60A1803Q01
ME60A2403Q01
ME60A4803Q01
12.0V
15.0V
18.0V
24.0V
48.0V
5.0V
5.00A
4.00A
3.30A
2.70A
1.35A
7.00A
5.00A
4.00A
3.30A
2.70A
1.35A
7.00A
5.00A
4.00A
3.30A
2.70A
1.35A
60W
60W
60W
60W
60W
35W
60W
60W
60W
60W
60W
35W
60W
60W
60W
60W
60W
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
480mV pk-pk
75mV pk-pk
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
480mV pk-pk
75mV pk-pk
120mV pk-pk
150mV pk-pk
180mV pk-pk
240mV pk-pk
480mV pk-pk
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
Class I Desktop,
IEC60320 C14
Receptacle
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
6 pin Molex Type3
12.0V
15.0V
18.0V
24.0V
48.0V
5.0V
Class II Desktop,
IEC60320 C8
Receptacle
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
6 pin Molex Type3
12.0V
15.0V
18.0V
24.0V
48.0V
Class II Desktop,
IEC60320 C18
Receptacle
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
Notes:
1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1μF ceramic and 10μF low ESR capacitors. For 5V
models, values listed are typical, 100mV pk-pk maximum.
2. Molex p/n 39-01-2060 or equivalent. See outline drawing for pinout information.
3. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE60B1203F01).
4. All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
www.slpower.com
ME60 Rev 2.4
31-JAN-16
1
ME60
60W Single Output External Power
Medical Series
General Specifications
Less than 1 sec @115Vac, full load
20mS min., at full Load, 100Vac input
AC Input 100-240Vac, ±10%, 47-63Hz, 1∅
Turn On Time
Hold-up Time
115Vac: 1.5A, 230Vac: 0.75A
Input Current
Inrush Current
Input Fuses
Overtemperature
Protection
Will shutdown upon an overtemperature
condition, auto-recovery.
264Vac, cold start: will not exceed 40A
F1, F2: 2A, 250Vac fuses (line & neutral lines)
provided on all models
130 to 180% of rating, Hiccup Mode
Hiccup Mode, auto recovery.
Overload Protection
Earth Leakage
Current
Short Circuit
Protection
Input-GND: <500μA@264Vac, 60Hz, NC
Output-GND: <4mA@264Vac, 60Hz, NC
Overvoltage
Protection
130 to 150% of output voltage (max. 60V on
48V model), hiccup mode
>88%, typical
Efficiency
Input-Output: 2 MOPP
Input-Ground: 1 MOPP
Output-Ground: 1 MOPP
60W continuous – See models chart for
specific voltage model ratings.
Output Power
Isolation
EN/IEC/UL60601-1, 3rd edition and
EN/IEC/UL60601-1-11:2010 for Home
Healthcare
No Load Input
Power
<0.210W (meets DoE Efficiency Level VI
Requirements)
Safety Standards
-20°C to +50°C. Derate above 40°C.
Operating
Temperature
See models chart on pg 1.
Ripple and Noise
Output Voltage
Start Up at -40°C, full load, (warmup period before
all parameters are within published specifications).
Temperature
Derating
Derate output power above 40°C to TBD at
50°C
See models chart on pg 1.
500µs response time for return to within 0.5%
Transient of final value for any 50% load step over the
-40°C to +85°C
Storage Temperature
range of 5% to 100% of rated load, ∆i/∆t<
0.2A/µs. Max. voltage deviation is +/-3.5%.
Response
Operating: to 5000m.
Non-operating: -500 to 40,000 ft.
See models chart on pg 1.
Regulation
Altitude
1.4m from table top to wooden platform, 4
faces.
5% to 95%, non-condensing
Drop Test
Vibration
Relative Humidity
Operating: 0.003g/Hz, 1.5grms overall, 3
axes, 10 min/axis, 1-500Hz.
Operating: Half-sine, 20gpk, 10mS, 3 axes,
6 shocks total
Non-Operating: Half-sine waveform, impact
acceleration of 100G, Pulse duration of 6
mS, Number of shocks: 3 for each of the
three axis
Non-Oper.: random waveform, 3 minutes per
axis, 3 axes and Sine waveform, Vib.
frequency/acceleration: 10-500Hz/1g, sweep
rate of 1 octave / minutes, Vibration time of 10
sweeps / axes, 3 axes
Shock
>250,000 hours, full load, 110 & 220Vac
input, 25°C amb., per Telcordia 332 Issue 6.
W: 2.67” x L: 4.25” x H: 1.29”
W: 67.9mm x L: 108mm x H: 32.7mm
Dimensions
Weight
MTBF
>7 year life based on calculations at
115Vac/60Hz & 230Vac/50Hz, ambient 25°C
at 24 hrs per day, 365 days/year, 6 power up
cycles per day. (80% load on 5V, 12V model)
400g
E-Cap Life
All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
www.slpower.com
ME60 Rev 2.4
31-JAN-16
2
ME60
60W Single Output External Power
Medical Series
EMI/EMC Compliance
EN55011/CISPR11 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac
EN55011/CISPR11 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac
High Frequency (100kHz-20MHz): <40mA pk-pk
Conducted Emissions:
Radiated Emissions:
Common Mode Noise:
Electro-Static Discharge (ESD)
Immunity on Power ports:
EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A
IEC60601-1-2, 4th Edition, Table 4
EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz
IEC60601-1-2, 4th Edition, Table 4
Radiated RF EM Fields Susceptibility
Electrical Fast Transients (EFT) /Bursts:
EN55024/IEC61000-4-4, Level 4, +/- 4.4kV, 100Khz rep rate, 40A, Criteria A
IEC60601-1-2, 4th Edition, Table 5
Surges, Line to Line (Diff Mode) and Line
to GND (CMN Mode)
EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A
Surpasses IEC60601-1-2, 4th Edition requirements.
EN55022/IEC61000-4-6, 3.6V/m – Level 4, 0.15 to 80Mhz; and 12V/m) in ISM and amateur
radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz
IEC60601-1-2, 4th Edition, Table 5
Conducted Disturbances induced by RF
Fields
EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz
IEC60601-1-2, 4th Edition, Table 4
Rated Power frequency magnetic fields
EN55024/IECEN61000-4-11: --100% dip for 20mS, Criteria A
--100% dip for 5000mS (250/300 cycles), Criteria B
--60% dip for 100mS, Criteria B
Voltage Interruptions, Dips, Sags &
Surges
--30% dip for 500mS, Criteria A
IEC60601-1-2, 4th Edition, Table 5
EN55011/EN61000-3-2, Class A
EN61000-3-3
Harmonic Current Emissions
Flicker Test
All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
Mechanical Drawing
12V through 48V Models: 2.5 x 5.5 x 9.5mm
Barrel Connector, center positive.
5V Models: Output Connector: 6 pin Molex 39-01-2060
or equiv. Pins 1, 4 = (+), pins 3, 6 = (-), pins 2, 5 = NC
Notes:
1) All dimensions in mm.
2) 2.5mm barrel connector shown, other options are available.
3) The unit should not be covered or enclosed to protect against excessive case temperature rise.
www.slpower.com
ME60 Rev 2.4
31-JAN-16
3
ME60
60W Single Output External Power
Medical Series
Connector Information
Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive. Other standard options are listed below.
The “03” in the standard model number is replaced by the applicable digits below:
Data Sheet © 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
www.slpower.com
ME60 Rev 2.4
31-JAN-16
4
相关型号:
ME61XAA-R155.5200MHZ
PECL 10KH Output Clock Oscillator, 155.52MHz Nom, ROHS COMPLIANT, DIP-14/4
MTRONPTI
ME61XAA-R19.4400MHZ
PECL 10KH Output Clock Oscillator, 19.44MHz Nom, ROHS COMPLIANT, DIP-14/4
MTRONPTI
ME61XAA19.4400MHZ
PECL 10KH Output Clock Oscillator, 19.4MHz Min, 155.52MHz Max, 19.44MHz Nom, DIP-14/4
MTRONPTI
©2020 ICPDF网 联系我们和版权申明