NMX-354-1512 [SLPOWER]

350 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT, FORCED CURRENT SHARING;
NMX-354-1512
型号: NMX-354-1512
厂家: SL Power Electronics    SL Power Electronics
描述:

350 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT, FORCED CURRENT SHARING

输出元件
文件: 总2页 (文件大小:104K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
3 5 0 WATTS  
P OWER FACTOR CORRECTED  
MULTIP LE OUTP UT, FORCED CURRENT S HARING  
NMX-350  
Option V  
Option E  
STANDARD NMX SERIES  
Featuring:  
Forced current sharing for N +1  
MODEL  
PWR OUTPUT #1  
OUTPUT #2  
OUTPUT #3  
OUTPUT #4  
redundancy  
NMX-353-0512  
NMX-354-1205  
NMX-354-1212  
NMX-354-1224  
NMX-354-1512  
NMX-354-1524  
350  
350  
350  
350  
350  
350  
+5V @ 50A  
+5V @ 50A  
+5V @ 50A  
+5V @ 50A  
+5V @ 50A  
+5V @ 50A  
+12V @ 8/12A pk  
+12V @ 8/12A pk  
+12V @ 8/12A pk  
+12V @ 8/12A pk  
+15V @ 4A  
-12V @ 4A  
-12V @ 4A  
-12V @ 4A  
-12V @ 4A  
-15V @ 4A  
-15V @ 4A  
Universal AC input  
0.99 typical power factor  
Dual converter design eliminates  
interaction between logic and  
auxiliary outputs  
5.2V @ 5A  
12V @ 5A  
24V @ 3A  
12V @ 5A  
24V @ 3A  
+15V @ 4A  
Low ripple and noise on all outputs  
DC power good and AC power fail  
signals  
The smallest, most capable 350 W  
power supply of its kind.  
Designed for applications using the lat-  
est logic families, the outputs’ turn-on and  
turn-off are monotonic. Turn-on transition  
is less than 200 ms. The highly effective  
N +1 configuration lets the main output  
from the NMX power supply work in  
conjunction with the main output of any  
similar power supply of the same voltage.  
This provides expanded capability, great  
flexibility in OEM design, and fail-safe  
redundancy.  
True remote inhibit  
Monotonic turn-on and turn-off  
Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com  
3 5 0 WATTS  
8 .0 5 ” x 4 .8 2 ” x 1 .8 5 ”  
NMX-3 5 0  
NMX-350  
NMX-350 with Option F  
2.6 lbs - 1.2 kgs  
3.0 lbs - 1.4 kgs  
Dimensions:  
Inches  
Millimeters  
SPECIFICATIONS: ALL MODELS  
OPTIONS:  
Option “E, Euro Style Connector: Provides input and auxiliary output connections accepting  
14 to 24 AWG wire.  
Option “F”, Fan/Cover Assembly: Cover with integral ball-bearing fan provides proper cool  
ing to achieve full ratings at 50°C ambient temperature. 1.85” dimension increases to 3.08”.  
Option “V, Fan/Cover Assembly: Low profile, end venting cover with integral ball-bearing fan.  
1.85” dimension increases to 2.50”, and 8.05” dimension increases to 9.40”.  
INPUT  
AC Input: 90-264 Vac continuous range, 47 to 63 Hz. Internally fused for 7 A.  
Power Factor: 0.99 typical at full load. Meets EN61000-3-2.  
Inrush: Cold start AC current is less than 30 A at 115 Vac and 60 A at 230 Vac. Limited by  
thermistor.  
Brownout Protection: Holds regulation to 85 Vac.  
Holdup Time: 20 ms minimum after removal of power at full load.  
Efficiency: 75% typical.  
Consult factory for other available options.  
AC Power Fail: Provides TTL 0” 5 ms before output voltage goes out of regulation band upon  
loss of ac power.  
AC INPUT (90-264 VAC Continuous Range)  
FUNCTION  
115 VAC  
230 VAC  
CONNECTOR  
Barrier strip  
#6-32 screws  
0.325” Centers  
OUTPUT  
(L)  
TB1-  
TB1-  
TB1-  
Line  
Line 1  
Line 2  
Adjustability: Outputs #1 and 2 user adjustable ±5% minimum. Output #3 tracks #2; initial  
accuracy ±4%. Output #4 user adjustable ±5% minimum, or +5% only if voltage is 5.2 V.  
Line & Load Reg: Outputs #1, 2, and 4 hold ±1% over AC input range and 0 to 100% load  
change. Output #3 requires 20% minimum load on outputs #2 and 3 to hold ±4%.  
Ripple & Noise: Less than 1% p-p or 100 mV, whichever is greater.  
Remote Sense (Output #1): Compensates for 250 mV total line drop. Open sense lead  
protection. (See Redundancy, below)  
Temperature Coefficient (Outputs #1, 2, and 4): 0.02% per degree C.  
Stability: 0.1% over 8 hours after 30 minutes warm-up.  
Transient Response (Outputs #1, 2, and 4): Output voltage returns to within 1% in less than  
500 µs for a 50% load change. Peak transient does not exceed 5%.  
Overload Protection: All outputs are protected against overload and short circuit. Automatic  
recovery upon removal of fault.  
Overvoltage Protection (Outputs #1 and 2): Protects load against power supply induced  
overvoltage. Trip point is factory set so that output voltage cannot exceed 136% of nominal.  
Peak Output Current: Dual current ratings define continuous and peak currents. The peak current  
shown can be delivered for a maximum period of 30 seconds.  
Remote Inhibit: Contact closure to the negative sense line or a TTL level “0” turns off DC  
outputs.  
(N)  
Neutral  
(
)
Safety Ground  
Safety Ground  
DC OUTPUT  
FUNCTION  
LOCATION  
NOTES  
CONNECTOR  
Output #1  
Terminal marked +V Main output  
Bus bars  
#8-32 screws  
Terminal marked -V  
J1-1, 6  
Rtn (common)  
Rtn (common)  
Rtn (common)  
Output #2  
Output #3  
Output #4  
J1-2, 7  
AMP #770743-1  
mates with connector  
770580-1with sockets  
#171639-1  
J1-3, 8  
J1-2, 7  
J1-4, 9  
(+) Floating  
Output  
(AWG #20 to #16)  
J1-5, 10  
(–) Floating  
Output  
DC Power Good: Provides a TTL “1” open collector when output #1 is above 4.6 V nominal.  
Redundancy: External OR-ing diodes and forced current sharing on output #1 provide “N+1”  
capability. Remote sense (+S) compensates for additional 0.6 V diode voltage drop. When  
the current sharing terminal is connected between units, current sharing remains within  
10% of the units full output current rating.  
STATUS AND CONTROL  
FUNCTION  
LOCATION  
NOTES  
CONNECTOR  
Remote Sense  
J2-1  
J2-2  
J2-3  
J2-5  
Output #1 Sense  
Output #1 Sense Rtn  
AMP MTA type  
#640456-6 pin  
header (locking)  
Reverse Voltage: Protected against reverse voltage up to supply current rating.  
DC Power Good  
Inhibit  
Reference to Common  
when #1 Sense Rtn  
is terminated  
ENVIRONMENTAL  
Thermal Protection: Shuts down power supply if overheated. Automatic recovery.  
Temperature Range: 0° to 50°C at full ratings.  
Safety Agencies: Most models are approved to UL1950; CSA 22.2 #234; IEC 950 and TÜV  
EN60950, Class 1 SELV., CE 72/23/EEC/93/68EEC (low voltage directive)..  
Conducted RFI: Meets FCC Part 15, Subpart J, Class A; EN55022 Class B; CISPR 22 Class B.  
Output Isolation: Isolated from ground 50 Vdc.  
Current Share  
J2-6  
J2-4  
J3-2  
J3-1  
AC Power Fail  
Reference to Common  
+12V @ 0.5A Output  
Rtn (Common)  
Aux. Fan Voltage  
(Not available with  
Vor “F” options)  
AMP MTA type  
#640456-2 pin  
header (locking)  
Cooling: 30 CFM required to achieve full ratings.  
Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com  

相关型号:

NMX-354-1524

350 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT, FORCED CURRENT SHARING
SLPOWER

NMX-500

500 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT, FORCED CURRENT SHARING
SLPOWER

NMX-503-0512

500 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT, FORCED CURRENT SHARING
SLPOWER

NMX-504-1205

500 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT, FORCED CURRENT SHARING
SLPOWER

NMX-504-1212

500 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT, FORCED CURRENT SHARING
SLPOWER

NMX-504-1224

500 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT, FORCED CURRENT SHARING
SLPOWER

NMX-504-1512

500 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT, FORCED CURRENT SHARING
SLPOWER

NMX-504-1524

500 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT, FORCED CURRENT SHARING
SLPOWER

NMX-750

750 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT, FORCED CURRENT SHARING
SLPOWER

NMX-753-0512

750 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT, FORCED CURRENT SHARING
SLPOWER

NMX-754-1205

750 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT, FORCED CURRENT SHARING
SLPOWER

NMX-754-1212

750 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT, FORCED CURRENT SHARING
SLPOWER