TCM-1000-48 [SLPOWER]

1000 WATTS POWER FACTOR CORRECTED POWER FACTOR CORRECTED;
TCM-1000-48
型号: TCM-1000-48
厂家: SL Power Electronics    SL Power Electronics
描述:

1000 WATTS POWER FACTOR CORRECTED POWER FACTOR CORRECTED

文件: 总2页 (文件大小:125K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
1 0 0 0 WATTS  
P OWER FACTOR CORRECTED  
S INGLE OUTP UT, HOT S WAP  
TCM-1000  
Featuring:  
STANDARD TCM SERIES  
Diode isolated output for hot swap  
MODEL  
OUTPUT RATING  
PWR OUT  
“Zero wire” slope program current  
TCM-1000-24  
TCM-1000-28  
TCM-1000-48  
24V @ 41.6A  
28V @ 35.7A  
48V @ 20.8A  
1000  
1000  
1000  
sharing  
High power density 6.5 Watt/cu. in.  
Industry standard DIN connector  
0.99 typical power factor  
The 1000-watt TCM Series “hot swap-  
pable” power supplies deliver remarkable  
economy and reliability in applications  
that require redundancy over extended  
temperature ranges. These high-density,  
single-output supplies are available  
with a front panel and handle for use in  
sub-system racks or without handles  
for embedded applications.  
Power factor correction, OR-ing diodes,  
and current sharing make the TCM  
Series an ideal choice for communica-  
tions and data processing systems  
utilizing distributed power or redundant  
power architecture.  
DC power good and AC power  
fail signals  
True remote inhibit  
Monotonic turn-on and turn-off  
Extended temperature operation  
High efficiency 87% typical  
(48 V units)  
Operating temperature range  
-20°C to +60°C  
Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com  
1 0 0 0 WATTS  
1 3 .2 7 ” x 4 .8 7 ” x 2 .4 9 ”  
TCM-1 0 0 0  
TCM-1000  
5.2 lbs - 2.6 kgs  
Dimensions:  
Inches  
Millimeters  
ENVIRONMENTAL  
SPECIFICATIONS: ALL MODELS  
Thermal Protection: Shuts down power supply if overheated. Automatic recovery.  
Temperature Range: -20° to +60° C, full power, de-rate to 66% maximum power @ 71° C.  
Safety Agencies: Approved to UL1950; CSA 22.2 #950; IEC 950 and TUV EN60950,  
Class 1 SELV, CE 73/23/EEC//93/68/EEC (low voltage directive).  
Conducted RFI: Meets FCC Part 15, Subpart J, Class A; EN55022 Class B;  
and CISPR 22 Class B.  
INPUT  
AC Input: 180-264 Vac, 47-63 Hz internally fused 10 A.  
Power Factor: 0.99 typical at full load. Meets EN61000-3.2.  
Inrush: Limited by thermistor, 40 Ampere maximum (8ms), cold start.  
Hold Up Time: 20 ms minimum after removal of power supply at full load.  
Efficiency: 87% typical @ full load.  
Output Isolation: Isolated from ground 100 Vdc.  
AC Power Fail: Provides TTL "O" 5 ms before output voltage goes out of regulation  
band upon loss of AC power.  
Cooling: Self-cooled by internal ball-bearing fan.  
OUTPUT  
OPTIONS  
Adjustability: User adjustable ±5% minimum.  
Output: 48 V @ 20.8 Amp. (1000 W max.).  
Line Regulation: ±0.2%  
Option "R" - Rack Mount Panel: special panel that is required for rack mounting.  
Consult factory for other available options.  
Load Regulation: ±2% (Slope Program) from 0 to 100% load changes.  
Turn On Delay: 1 second typical.  
Ripple & Noise: 0.5% p-p, measured at 20 MHz bandwidth.  
Temperature Coefficient: 0.02% per degree C.  
AC INPUT (180-264 VAC Continuous Range)  
Stability: 0.1% over 8 hours, under constant line, load and ambient.  
Transient Response: Output voltage returns to within 1% in less than 500 µs for a  
50% load change. Peak transient does not exceed 3%.  
Overload Protection: Electronic current limit, 120% maximum.  
Overvoltage Protection: Protects load against power supply induced overvoltage.  
Trip point is factory set so that output voltage cannot exceed 136% of nominal.  
Requires AC input to be cycled to reset.  
Remote Inhibit: Contact closure or TTL "0" turns off output.  
DC Power Good: Provides a TTL "0" open collector when output is above 90% of  
nominal Maximum pull-up voltage 30 Vdc; maximum sink current, 10 mA.  
Redundancy: Built-in OR-ing diode, slope program current sharing, and DIN blade  
connector provide "hot swap" and "N+1" capabilities. Current sharing remains  
within 10% of the unit's full output rating given 0.2% initial accuracy in the  
output voltage setting.  
LOCATION  
230 VAC  
CONNECTOR  
Z32  
D30  
Z28  
Line 1  
Eurocard Connector -  
Male DIN 41 612  
Level 1- Type H  
Line 2  
Safety Ground  
DC OUTPUT  
FUNCTION  
Output  
LOCATION  
NOTES  
CONNECTOR  
Eurocard Connector -  
Male DIN 41 612  
Level 1- Type H  
Z12 D14 Z16 D18  
Z4 D6 Z8 D10  
(+) Polarity  
(-) Polarity  
Voltage  
Current Sharing: As calibrated at factory, modules will share current within  
10% of full rated load.  
Reverse Voltage: Protected against reverse voltage up to twice output voltage rating.  
(internal OR-ing diode.)  
STATUS AND CONTROL  
FUNCTION  
DC Power Good  
AC Power Fail  
Inhibit  
LOCATION  
NOTES  
CONNECTOR  
Eurocard Connector -  
Male DIN 41 612  
Level 1- Type H  
Z20  
D22  
Z24  
Reference to  
Common  
Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com  

相关型号:

TCM-1C127U-IM

RF/Microwave Antenna
ONSEMI

TCM-2021-122.880MHZ

IC,PHASE-LOCKED LOOP,LLCC,8PIN,PLASTIC
SEIKO

TCM-2021-230.000MHZ

IC,PHASE-LOCKED LOOP,LLCC,8PIN,PLASTIC
SEIKO

TCM-3185

TM0127AAA6
ETC

TCM-3185-012

TM0127AAA6
ETC

TCM-BF537

Bluetechnix Mechatronische Systeme GmbH
ETC

TCM-ED8064/1

RF Transformer, 0.5MHz Min, 350MHz Max
MINI

TCM-ED8064/1+

RF Transformer, 0.5MHz Min, 350MHz Max
MINI

TCM0403M-120-2P-T210

共模滤波器/扼流圈
TDK

TCM0403M-350-2P-T210

共模滤波器/扼流圈
TDK

TCM0403M-900-2P-T210

共模滤波器/扼流圈
TDK

TCM0403S-350-2P-T

Data Line Filter
TDK