TE40A2403Q01 [SLPOWER]
40W Single Output External Power;型号: | TE40A2403Q01 |
厂家: | SL Power Electronics |
描述: | 40W Single Output External Power |
文件: | 总5页 (文件大小:764K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
TE40
40W Single Output External Power
Test & Measurement/Industrial Series
Features
.
Meets DoE Efficiency Level VI Requirements
.
.
No load input power
Average Efficiency
.
.
.
.
Up to 40W of AC-DC Power
Universal Input 90-264Vac Input Range
Desktop and Wall-Plug versions
Meets “Heavy Industrial” Levels of EN61000
EMC Requirements
.
Meets EN55011/CISPR11, and FCC Part
15.109 Class B Conducted & Radiated
Emissions, with 6db margin
.
.
.
.
.
Approved to EN/IEC/UL60950-1, 2nd Ed., Am. 2
E-cap life of >8 years
>1,000,000 hours MTBF
3 Year Warranty
RoHS Compliant
Description
A high performance AC to DC external power supply family designed for test & measurement and industrial applications.
The TE40A Series models are compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, as well as the
Heavy Industrial levels of various EN61000-4-x standards for EMC. The TE40A series models also meets Class B
conducted and radiated emissions per FCC Part 15, EN55022, and CISPR22, with margin.
Model Selection
Overvoltage
Trip Range
Output
Connector
Input
Configuration
Model
Output
Current
Output
Power
Ripple &
Noise¹
Line
Regulation
Load
Regulation
Number
Volts
TE40A1203F01
TE40A1803F01
TE40A2403F01
TE40A1203N01
TE40A1803N01
TE40A2403N01
TE40A1203Q01
TE40A1803Q01
TE40A2403Q01
TE40A1203B01
TE40A1803B01
TE40A2403B01
TE40A1203C01
TE40A1803C01
TE40A2403C01
12.0V
3.40A
2.20A
1.70A
3.40A
2.20A
1.70A
3.40A
2.20A
1.70A
3.40A
2.20A
1.70A
3.40A
2.20A
1.70A
40W
40W
40W
40W
40W
40W
40W
40W
40W
40W
40W
40W
40W
40W
40W
120mV pk-pk
180mV pk-pk
240mV pk-pk
120mV pk-pk
180mV pk-pk
240mV pk-pk
120mV pk-pk
180mV pk-pk
240mV pk-pk
120mV pk-pk
180mV pk-pk
240mV pk-pk
120mV pk-pk
180mV pk-pk
240mV pk-pk
120%-150%
120%-150%
120%-140%
120%-150%
120%-150%
120%-140%
120%-150%
120%-150%
120%-140%
120%-150%
120%-150%
120%-140%
120%-150%
120%-150%
120%-140%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
±5%
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
Class I Desktop,
IEC60320 C14
Receptacle
18.0V
24.0V
12.0V
18.0V
24.0V
12.0V
18.0V
24.0V
12.0V
18.0V
24.0V
12.0V
18.0V
24.0V
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
Class I Desktop,
IEC60320 C8
Receptacle
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
Class II Desktop,
IEC60320 C18
Receptacle
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
Class II Wall-Plug,
Interchangeable
Blades²
2.5 x 5.5 x 9.5mm
Straight Barrel Type,
center positive
Class II Wall-Plug,
Fixed North
American Blades³
Notes:
1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1μF ceramic and 10μF low ESR capacitors.
2. Standard models are fitted with North American blades. Order blade kit KT-1027K for other blades (EU. UK, Australia)
3. For EU fixed blades, replace “C” in the model number with “M”, for UK blades, replace “C” with “G”, for Australia blades, replace “C” with “H”.
4. All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
5. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE40B1203F01).
www.slpower.com
TE40 Rev 2.1
2-MAY-16
1
TE40
40W Single Output External Power
Test & Measurement/Industrial Series
General Specifications
Less than 700mS @115Vac, full load
20mS min., at full Load, 100Vac input
AC Input 100-240Vac, ±10%, 47-63Hz, 1∅
Turn On Time
Hold-up Time
115Vac: 1.2A, 230Vac: 0.6A
264Vac, cold start: will not exceed 40A
2.0A, 250Vac
Input Current
Inrush Current
Input Fuses
Overtemperature
Protection
Will shutdown upon an overtemperature
condition, auto-recovery.
130% - 160%, Hiccup Mode
Hiccup Mode, auto recovery.
Overload Protection
Earth Leakage
Current
Short Circuit
Protection
Input-GND: <500μA@264Vac, 60Hz, NC
Output-GND: <4mA@264Vac, 60Hz, NC
Overvoltage
Protection
Meets US DoE Efficiency Level VI Average
efficiency levels
Hiccup Mode. See models chart for trip
ranges.
Efficiency
Input-Output: 4000Vac
Input-Ground: 1500Vac
Output-Ground: 1500Vac
40W continuous – See models chart for
specific voltage model ratings.
Output Power
Isolation
No Load Input
Power
<0.1W per DoE Efficiency Level VI
Requirements
EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2
Safety Standards
-20°C to +70°C
Start Up at -40°C, full load, (warmup period before
all parameters are within published specifications).
Operating
Temperature
See models chart on pg 1.
Ripple and Noise
Output Voltage
Temperature
Derating
See models chart on pg 1.
See derating chart.
-40°C to +85°C
500µs response time for return to within 0.5%
Transient of final value for any 50% load step over the
Storage Temperature
range of 5% to 100% of rated load, ∆i/∆t<
0.2A/µs. Max. voltage deviation is +/-3.5%.
Response
Operating: to 5000m.
Non-operating: -500 to 40,000 ft.
See models chart on pg 1.
Regulation
Altitude
1.4m from table top to wooden platform, 6
faces.
5% to 95%, non-condensing
Drop Test
Vibration
Relative Humidity
Operating: 0.003g/Hz, 1.5grms overall, 3
axes, 10 min/axis, 1-500Hz.
Operating: Half-sine, 20gpk, 10mS, 3 axes,
6 shocks total
Non-Operating: Half-sine waveform, impact
acceleration of 100G, Pulse duration of 6
mS, Number of shocks: 3 for each of the
three axis
Non-Oper.: random waveform, 3 minutes per
axis, 3 axes and Sine waveform, Vib.
frequency/acceleration: 10-500Hz/1g, sweep
rate of 1 octave / minutes, Vibration time of 10
sweeps / axes, 3 axes
Shock
>250,000 hours, full load, 110 & 220Vac
input, 25°C amb., per Telcordia 332 Issue 6.
See outline drawings
Dimensions
Weight
MTBF
>7 year life based on calculations at
115Vac/60Hz & 230Vac/50Hz, ambient 25°C
at 24 hrs per day, 365 days/year, 6 power up
cycles per day. (@80% load for the 12V model)
250g
E-Cap Life
All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
www.slpower.com
TE40 Rev 2.1
2-MAY-16
2
TE40
40W Single Output External Power
Test & Measurement/Industrial Series
EMI/EMC Compliance
EN55011/CISPR22 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac
EN55022/CISPR22 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac
High Frequency (100kHz-20MHz): <40mA pk-pk
Conducted Emissions:
Radiated Emissions:
Common Mode Noise:
Electro-Static Discharge (ESD)
Immunity on Power ports:
EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A
EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz
Radiated RF EM Fields Susceptibility
Electrical Fast Transients (EFT) /Bursts:
EN55024/IEC61000-4-4, Level 4, +/- 4kV, 100Khz rep rate, 40A, Criteria A
EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A
Surges, Line to Line (Diff Mode) and Line
to GND (CMN Mode)
Conducted Disturbances induced by RF
Fields
EN55022/IEC61000-4-6, 3V/m – Level 4, 0.15 to 80Mhz; and 12V/m) in ISM and amateur radio
bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz
EN55024/IEC1000-4-8, Level 4: 30A/m, 50/60 Hz
Rated Power frequency magnetic fields
EN55024/IECEN61000-4-11:
--100% dip for 20mS, Criteria A
--100% dip for 5000mS (250/300 cycles), Criteria B
--60% dip for 100mS, Criteria B
Voltage Interruptions, Dips, Sags &
Surges
--30% dip for 500mS, Criteria A
EN55011/EN61000-3-2, Class A
EN61000-3-3
Harmonic Current Emissions
Flicker Test
. All specifications are typical at nominal input, full load, at 25°C ambient unless noted.
Derating Chart
www.slpower.com
TE40 Rev 2.1
2-MAY-16
3
TE40
40W Single Output External Power
Test & Measurement/Industrial Series
Mechanical Drawing
54
33.6
55
IEC60320 C14 Receptacle, 2.5 x 5.5 x 9.5mm Barrel Connector
Interchangeable N.A. Blade, 2.5 x 5.5 x 9.5mm barrel connector
Notes:
1. All dimensions in mm.
2. Interchangeable blade models come with North American blade fitted. For other blades (EU, UK, Aust.) order blade kit KT1027K.
Connector Information
Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive. Other standard options are listed below.
The “03” in the standard model number is replaced by the applicable digits below:
www.slpower.com
TE40 Rev 2.1
2-MAY-16
4
TE40
40W Single Output External Power
Test & Measurement/Industrial Series
Efficiency Level VI Information:
TE40A Series
Data Sheet © 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
www.slpower.com
TE40 Rev 2.1
2-MAY-16
5
相关型号:
©2020 ICPDF网 联系我们和版权申明