Surface Mount 2-Electrode Gas Discharge Tube (GDT)  
SC1210 Series  
Description  
Gas discharge Tubes (GDT) are classical components for  
protecting the installations of the telecommunications. It is  
essential that IT and telecommunications systems -with their  
high-grade but sensitive electronic circuits - be protected by  
arresters.  
The 1210 series GDT offers high surge ratings in a miniature  
package. It’s designed for surface mounting on PCB with small size  
3.2x2.5x2.5mm. Low insertion loss is perfectly suited to broadband  
equipment applications. The capacitance does not vary with  
voltage, and will not cause operational problems with ADSL2+,  
Schematic Symbol  
where capacitance variation across Tip and Ring is undesirable.  
These devices are extremely robust and are able to divert a 500A  
pulse in a miniature package 1210 without destruction.  
Features  
Product Characteristics  
Non-Radioactive  
Materials  
Dull Tin-plated  
RoHS compliant  
Product Marking Without  
Ultra low capacitance (<1.0pF)  
UL recognized  
Storage and  
Operational  
Temperature  
-40 to +90°C  
Excellent response to fast rising transients  
1KA surge capability tested with 8/20μs  
pulse as defined by IEC 61000-4-5  
Square Outline  
Weight  
~80mg  
Climatic category  
(IEC 60068-1)  
40/ 90/ 21  
Applications  
Communication equipment  
CATV equipment  
Test equipment  
Data lines  
Power supplies  
Telecom SLIC protection  
Broadband equipment  
ADSL equipment, including ADSL2+  
XDSL equipment  
Satellite and CATV equipment  
General telecom equipment  
ESD protection  
SOCAY Electronics Corp., Ltd.  
www.socay.com  
@SOCAY Electronics Corp., Ltd. 2019  
Revision January 4, 2019  
1 / 4  
Specifications are subject to change without notice.  
Please refer to www.socay.com for current information.  
Surface Mount 2-Electrode Gas Discharge Tube (GDT)  
SC1210 Series  
Device Dimensions  
(Unit: mm)  
Recommended pad outline  
Electrical Characteristics  
Nominal  
DC  
Spark-over  
Voltage  
Impulse  
Discharge  
Voltage  
Maximum Impulse  
Spark-over Voltage  
Maximum  
Capacitance  
Arc  
Voltage  
Impulse  
Discharge  
Current  
Minimum  
Insulation  
Resistance  
Part Number  
@8/20μs  
±5 times  
@100V/S  
@100V/μs  
@1KV/μs  
@1MHz  
@1A  
@10/700μs  
1 GΩ  
(at 50V DC)  
SC1210-150BSMD  
SC1210-200BSMD  
SC1210-230BSMD  
SC1210-300BSMD  
SC1210-350BSMD  
SC1210-400BSMD  
SC1210-420BSMD  
150V±20%  
200V±20%  
230V±20%  
300V±20%  
350V±20%  
400V±20%  
420V±20%  
470V±20%  
500V  
500V  
600V  
700V  
800V  
800V  
800V  
900V  
600V  
700V  
700V  
800V  
900V  
950V  
950V  
1000V  
1.0pF  
1.0pF  
1.0pF  
1.0pF  
1.0pF  
1.0pF  
1.0pF  
1.0pF  
~15V  
~15V  
~15V  
~15V  
~15V  
~15V  
~15V  
~15V  
1 KA  
1 KA  
1 KA  
1 KA  
1 KA  
1 KA  
1 KA  
1 KA  
8KV  
8KV  
8KV  
8KV  
8KV  
8KV  
8KV  
8KV  
1 GΩ  
(at 100V DC)  
1 GΩ  
(at 100V DC)  
1 GΩ  
(at 100V DC)  
1 GΩ  
(at 100V DC)  
1 GΩ  
(at 100V DC)  
1 GΩ  
(at 100V DC)  
1 GΩ  
(at 100V DC)  
SC1210-470BSMD  
Notes:  
1). Terms in accordance with ITU-T K.12 and GB/T 9043-2008  
2). At delivery AQL 0.65 level , DIN ISO 2859  
SOCAY Electronics Corp., Ltd.  
www.socay.com  
@SOCAY Electronics Corp., Ltd. 2019  
Revision January 4, 2019  
2 / 4  
Specifications are subject to change without notice.  
Please refer to www.socay.com for current information.  
Surface Mount 2-Electrode Gas Discharge Tube (GDT)  
SC1210 Series  
Electrical Rating  
Item  
Test Condition / Description  
Requirement  
DC Spark-over Voltage  
The voltage is measured with a slowly rate of rise dv / dt=100V/s  
Impulse Spark-over  
Voltage  
The maximum impulse spark-over voltage is measured with a rise time of  
dv / dt=100V//μs or 1KV/μs  
The resistance of gas tube shall be measured each terminal each other terminal,  
please see above spec.  
Insulation Resistance  
Capacitance  
The capacitance of gas tube shall be measured each terminal to each other  
terminal.  
Test frequency :1MHz  
The maximum current applying a waveform of 8/20μs that can be applied across  
the terminals of the gas tube. One hour after the test is completed, re-testing of the  
DC spark-over voltage does not exceed ±30% of the nominal DC spark-over  
To meet  
the specified  
value  
voltage. Dwell time between pulses is 3 minutes.  
I
1.0  
0.9  
Nominal Impulse  
Discharge Current  
0.5  
0.1  
0.0  
T
8μsec  
30% Max  
20μsec  
Recommended Soldering Profile  
Reflow Condition  
Pb - Free assembly  
150°C  
-Temperature Min (Ts(min)  
)
-Temperature Max (Ts(max)  
- Time (min to max) (ts)  
Pre Heat  
)
200°C  
TP  
Critical Zone  
60 -180 Seconds  
Ramp-up  
TL to TP  
TL  
Average ramp up rate ( Liquidus Temp TL)  
to peak  
3°C/second max  
TS(max)  
TS(max) to TL - Ramp-up Rate  
5°C/second max  
217°C  
Ramp-down  
- Temperature (TL) (Liquidus)  
Reflow  
TS(min)  
- Time (min to max) (ts)  
60 -150 Seconds  
260 +0/-5°C  
Preheat  
Peak Temperature (TP)  
25  
Time within 5°C of actual peak  
Temperature (tp)  
Time to peak temperature  
10 - 30 Seconds  
Time  
(t 25to peak)  
Ramp-down Rate  
6°C/second max  
8 minutes Max  
260°C  
Time 25°C to peak Temperature (TP)  
Do not exceed  
SOCAY Electronics Corp., Ltd.  
www.socay.com  
@SOCAY Electronics Corp., Ltd. 2019  
Revision January 4, 2019  
3 / 4  
Specifications are subject to change without notice.  
Please refer to www.socay.com for current information.  
Surface Mount 2-Electrode Gas Discharge Tube (GDT)  
SC1210 Series  
Part Numbering  
S C 1 2 1 0 – X X X B S M D  
SMD, Surface Mount  
8/20μs Level  
B, 1KA  
Nominal DC Spark-over Voltage  
150 = 150V  
200 = 200V  
350 = 350V  
400 = 400V  
Series  
Tape and Reel Dimensions  
(Unit: mm)  
Packaging  
Part Number  
Description  
Quantity  
SC1210-XXXBSMD  
12mm Tape & 7″ Reel  
1000 PCS  
Cautions and Warnings  
Gas discharge tubes (GDT) must not be operated directly in power supply networks.  
Gas discharge tubes (GDT) may become hot in case of longer periods of current stress (danger of burning).  
Gas discharge tubes (GDT) may be used only within their specified values. In the event of overload, the head contacts may  
fail or the component may be destroyed.  
Damaged Gas discharge tubes (GDT) must not be re-used.  
SOCAY Electronics Corp., Ltd.  
www.socay.com  
@SOCAY Electronics Corp., Ltd. 2019  
Revision January 4, 2019  
4 / 4  
Specifications are subject to change without notice.  
Please refer to www.socay.com for current information.  

相关型号:

SC1210-471

SMD POWER INDUCTORS Open frame construction
BEL

SC1210-4R7

SMD POWER INDUCTORS Open frame construction
BEL

SC1210-561

SMD POWER INDUCTORS Open frame construction
BEL

SC1210ML101K

Surface Mount Multilayer Varistor
SOCAY

SC1210ML180K

Surface Mount Multilayer Varistor
SOCAY

SC1210ML240K

Surface Mount Multilayer Varistor
SOCAY

SC1210ML270K

Surface Mount Multilayer Varistor
SOCAY

SC1210ML330K

Surface Mount Multilayer Varistor
SOCAY

SC1210ML390K

Surface Mount Multilayer Varistor
SOCAY

SC1210ML470K

Surface Mount Multilayer Varistor
SOCAY

SC1210ML560K

Surface Mount Multilayer Varistor
SOCAY

SC1210ML680K

Surface Mount Multilayer Varistor
SOCAY