UN2E5-3000DL [SOCAY]

High Voltage 2-Electrode Gas Discharge Tube (GDT);
UN2E5-3000DL
型号: UN2E5-3000DL
厂家: Socay Electornics Co., Ltd.    Socay Electornics Co., Ltd.
描述:

High Voltage 2-Electrode Gas Discharge Tube (GDT)

文件: 总4页 (文件大小:377K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
High Voltage 2-Electrode Gas Discharge Tube (GDT)  
UN2E5 Series  
UN2E5-XXXDL  
UN2E5-XXXD  
Description  
The high voltage (1.0- 3.5KV) gas discharge tubes are designed for  
surge protection and high isolation applications, and for  
applications for which bias voltages or signal levels of several  
hundred volts are normally present.  
Schematic Symbol  
Agency Approvals  
u
u
u
u
u
u
Non-Radioactive  
RoHS compliant  
Low insertion loss  
Excellent response to fast rising transients  
Ultra low capacitance  
5KA surge capability tested with 8/20μs  
pulse as dened by IEC 61000-4-5  
Product Characteristics  
Materials  
Nickel-plated with Tinplated wires  
UNION XXXXD  
XXXX -Nominal voltage  
Applications  
Product  
Marking  
D
-2.5KA  
u
u
u
u
u
CRT terminals  
CATV equipment  
Antennas  
Glow to Arc  
Transition  
Current  
< 0.5Amps  
~180 Volts  
Power supplies  
Medical electronics  
Glow Voltage  
Storage and  
Operational  
Temperature  
-40 to +90°C  
UN2E5-XXXDL  
UN2E5-XXXD  
~1.0g  
Weight  
~0.85g  
SOCAY Electronics Co., Ltd.  
www.socay.com  
@SOCAY Electronics Co., Ltd. 2013  
Revision October 18, 2013  
1 / 4  
Specifications are subject to change without notice.  
Please refer to www.socay.com for current information.  
High Voltage 2-Electrode Gas Discharge Tube (GDT)  
UN2E5 Series  
Dimensions  
(Unit: mm)  
Axial Leaded Devices (UN2E5-XXXDL)  
Without wire Devices (UN2E5-XXXD)  
Electrical Characteristics  
Service Life  
DC  
Spark-over  
Nominal  
Impulse  
Discharge Discharge  
Max  
Maximum Impulse  
Spark-over Voltage  
Maximum  
Capacitance Voltage  
Arc  
Minimum  
Insulation  
Resistance  
Impulse  
Voltage  
Part Number  
Marking  
Current  
@8/20μs  
±5 times  
Current  
@8/20μs  
1 time  
@100V/S  
@100V/μs @1KV/μs  
@1MHz  
@1A  
UN2E5-1000DL  
UN2E5-1000D  
1 GΩ  
(at 100V)  
1000D  
1600D  
2000D  
2500D  
2700D  
3000D  
3500D  
1000V±20%  
1500V  
2200V  
3000V  
3800V  
3800V  
4300V  
4800V  
1600V  
2400V  
3500V  
4000V  
4000V  
4500V  
5000V  
1.0pF  
~25V  
2.5KA  
2.5KA  
2.5KA  
2.5KA  
2.5KA  
2.5KA  
2.5KA  
5KA  
5KA  
5KA  
5KA  
5KA  
5KA  
5KA  
UN2E5-1600DL  
UN2E5-1600D  
1 GΩ  
(at 100V)  
1600V±20%  
2000V±20%  
2500V±20%  
2700V±20%  
3000V±20%  
3500V±20%  
1.0pF  
1.0pF  
1.0pF  
1.0pF  
1.0pF  
1.0pF  
~25V  
~25V  
~25V  
~25V  
~25V  
~25V  
UN2E5-2000DL  
UN2E5-2000D  
1 GΩ  
(at 100V)  
UN2E5-2500DL  
UN2E5-2500D  
1 GΩ  
(at 100V)  
UN2E5-2700DL  
UN2E5-2700D  
1 GΩ  
(at 100V)  
UN2E5-3000DL  
UN2E5-3000D  
1 GΩ  
(at 100V)  
UN2E5-3500DL  
UN2E5-3500D  
Notes:  
1 GΩ  
(at 100V)  
1). Terms in accordance with ITU-T K.12 and GB/T 9043-2008  
2). At delivery AQL 0.65 level , DIN ISO 2859  
SOCAY Electronics Co., Ltd.  
www.socay.com  
@SOCAY Electronics Co., Ltd. 2013  
Revision October 18, 2013  
2 / 4  
Specifications are subject to change without notice.  
Please refer to www.socay.com for current information.  
High Voltage 2-Electrode Gas Discharge Tube (GDT)  
UN2E5 Series  
Electrical Rating  
Item  
Test Condition / Description  
Requirement  
DC Spark-over Voltage  
The voltage is measured with a slowly rate of rise dv / dt=100V/s  
Impulse Spark-over  
Voltage  
The maximum impulse spark-over voltage is measured with a rise time of  
dv / dt=100V//μs or 1KV/μs  
The resistance of gas tube shall be measured each terminal each other terminal,  
please see above spec.  
Insulation Resistance  
Capacitance  
The capacitance of gas tube shall be measured each terminal to each other  
terminal.  
Test frequency :1MHz  
The maximum current applying a waveform of 8/20μs that can be applied across  
the terminals of the gas tube. One hour after the test is completed, re-testing of the  
DC spark-over voltage does not exceed ±30% of the nominal DC spark-over  
voltage. Dwell time between pulses is 3 minutes.  
To meet  
the specified  
value  
Nominal Impulse  
Discharge Current  
Recommended soldering profile  
Reflow soldering  
Wave soldering  
Soldering profile applied a single process  
Soldering Parameters - Hand Soldering  
Solder Iron Temperature: 350°C +/-5°C  
Heating Time: 5 seconds max.  
SOCAY Electronics Co., Ltd.  
www.socay.com  
@SOCAY Electronics Co., Ltd. 2013  
Revision October 18, 2013  
3 / 4  
Specifications are subject to change without notice.  
Please refer to www.socay.com for current information.  
High Voltage 2-Electrode Gas Discharge Tube (GDT)  
UN2E5 Series  
Part Numbering  
U N 2 E 5 X X X D L  
L,  
No,  
with axial wire  
without wire  
8/20μs Level  
D, 2.5KA  
Nominal DC Spark-over Voltage  
1000 = 1000V  
1600 = 1600V  
2000 = 2000V  
2500 = 2500V  
3000=3000V  
3500=3500V  
Series  
Packaging Information  
Unit: mm  
Part Number  
Description  
Quantity  
1000  
100PCS per Tray, 10 Trays / Inner Carton  
100PCS per Tray, 10 Trays / Inner Carton  
UN2E5-XXXDL  
UN2E5-XXXD  
1000  
Tray used in UN2E5-XXXDL  
Tray used in UN2E5-XXXD  
Cautions and warnings  
u
u
u
Gas discharge tubes (GDT) must not be operated directly in power supply networks.  
Gas discharge tubes (GDT) may become hot in case of longer periods of current stress (danger of burning).  
Gas discharge tubes (GDT) may be used only within their specified values. In the event of overload, the head contacts may  
fail or the component may be destroyed.  
u
Damaged Gas discharge tubes (GDT) must not be re-used.  
SOCAY Electronics Co., Ltd.  
www.socay.com  
@SOCAY Electronics Co., Ltd. 2013  
Specifications are subject to change without notice.  
Please refer to www.socay.com for current information.  
Revision October 18, 2013  
4 / 4  

相关型号:

UN2E5-300L

2-Electrode Gas Discharge Tube (GDT)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
UNSEMI

UN2E5-300L

2-Electrode Gas Discharge Tube (GDT)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SOCAY

UN2E5-300LL

2-Electrode Gas Discharge Tube (GDT)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
UNSEMI

UN2E5-300LL

2-Electrode Gas Discharge Tube (GDT)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SOCAY

UN2E5-300LSMD

Surface Mount 2-Electrode Gas Discharge Tube (GDT)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SOCAY

UN2E5-3500D

High Voltage 2-Electrode Gas Discharge Tube (GDT)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
UNSEMI

UN2E5-3500D

High Voltage 2-Electrode Gas Discharge Tube (GDT)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SOCAY

UN2E5-3500DL

High Voltage 2-Electrode Gas Discharge Tube (GDT)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
UNSEMI

UN2E5-3500DL

High Voltage 2-Electrode Gas Discharge Tube (GDT)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SOCAY

UN2E5-350L

2-Electrode Gas Discharge Tube (GDT)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
UNSEMI

UN2E5-350L

2-Electrode Gas Discharge Tube (GDT)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SOCAY

UN2E5-350LL

2-Electrode Gas Discharge Tube (GDT)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
UNSEMI