ILX551AG [SONY]

Image Sensor, 2048 Horiz pixels, 1 Vert pixels, Through Hole Mount,;
ILX551AG
型号: ILX551AG
厂家: SONY CORPORATION    SONY CORPORATION
描述:

Image Sensor, 2048 Horiz pixels, 1 Vert pixels, Through Hole Mount,

CD
文件: 总10页 (文件大小:124K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
ILX551A  
2048-pixel CCD Linear Sensor (B/W)  
For the availability of this product, please contact the sales office.  
Description  
22 pin DIP (Cer-DIP)  
The ILX551A is a reduction type CCD linear sensor  
designed for facsimile, image scanner and OCR use.  
This sensor reads B4 size documents at a density of  
200DPI (Dot Per Inch). A built-in timing generator  
and clock-drivers ensure direct drive at 5V logic for  
easy use.  
Features  
Number of effective pixels: 2048 pixels  
Pixel size: 14µm × 14µm (14µm pitch)  
Built-in timing generator and clock-drivers  
Ultra low lag  
Block Diagram  
Maximum clock frequency: 5MHz  
D 3 9  
D 3 8  
D 3 7  
D 3 6  
D 3 5  
D 3 4  
S 2 0 4 8  
S 2 0 4 7  
Absolute Maximum Ratings  
Supply voltage  
VDD1  
VDD2  
11  
6
V
V
Operating temperature  
Storage temperature  
–10 to +55 °C  
–30 to +80 °C  
Pin Configuration (Top View)  
S 2  
S 1  
VOUT  
VDD2  
VDD2  
VDD1  
GND  
NC  
1
22  
21  
20  
19  
18  
17  
D 3 3  
1
NC  
2
NC  
3
D 1 5  
D 1 4  
SHSW  
4
φCLK  
5
NC  
6
GND  
NC  
VDD2  
VDD2  
NC  
7
8
16 NC  
15 NC  
14 NC  
13 NC  
9
10  
φROG 11  
12  
GND  
2048  
Sony reserves the right to change products and specifications without prior notice. This information does not convey any license by  
any implication or otherwise under any patents or other right. Application circuits shown, if any, are typical examples illustrating the  
operation of the devices. Sony cannot assume responsibility for any problems arising out of the use of these circuits.  
– 1 –  
E00439-PS  
ILX551A  
Pin Description  
Pin  
Pin  
No.  
Symbol  
No.  
Description  
Signal output  
Symbol  
Description  
1
2
3
VOUT  
NC  
12 GND  
13 NC  
14 NC  
GND  
NC  
NC  
NC  
NC  
NC  
with S/H GND  
without S/H VDD2  
4
SHSW  
Switch  
15 NC  
NC  
{
5
6
7
8
9
φCLK  
NC  
Clock pulse  
16 NC  
17 GND  
18 NC  
19 GND  
NC  
NC  
GND  
NC  
NC  
NC  
VDD2  
VDD2  
5V power supply  
5V power supply  
NC  
GND  
20  
21  
22  
VDD1  
VDD2  
VDD2  
9V power supply  
5V power supply  
5V power supply  
10 NC  
11 φROG  
Clock pulse  
Recommended Supply Voltage  
Item  
Min.  
8.5  
Typ.  
9.0  
Max.  
9.5  
Unit  
V
VDD1  
VDD2  
4.75  
5.0  
5.25  
V
Note) Rules for raising and lowering power supply voltage  
To raise power supply voltage, first raise VDD1 (9V) and then VDD2 (5V).  
To lower voltage, first lower VDD2 (5V) and then VDD1 (9V).  
Mode Description  
Mode in use Pin condition  
S/H  
Yes  
No  
Pin 4 SHSW  
GND  
VDD2  
Input Capacity of Pins  
Item  
Symbol  
Min.  
Typ.  
10  
Max.  
Unit  
pF  
Input capacity of φCLK pin  
Input capacity of φROG pin  
CφCLK  
CφROG  
10  
pF  
Recommended Input Pulse Voltage  
Typ.  
5.0  
Max.  
Unit  
Item  
Input clock high level  
Input clock low level  
Min.  
4.5  
5.5  
0.5  
V
V
0.0  
– 2 –  
ILX551A  
Electrooptical Characteristics  
(Ta = 25°C, VDD1 = 9V, VDD2 = 5V, Clock frequency = 1MHz, Light source = 3200K, IR cut filter: CM-500S (t = 1.0mm))  
Max.  
50  
Item  
Symbol  
R
Min.  
30  
Typ.  
40  
Unit  
Remarks  
Secsitivity  
V/(lx · s) Note 1  
PRNU  
VSAT  
VDRK  
DSNU  
IL  
2.0  
8.0  
Sensitivity nonuniformity  
Saturation output voltage  
Dark voltage average  
Dark signal nonuniformity  
Image lag  
%
V
Note 2  
1.5  
1.8  
0.3  
2.0  
3.0  
mV  
mV  
%
Note 3  
Note 3  
Note 4  
Note 5  
Note 6  
0.5  
0.02  
6000  
0.045  
4.0  
DR  
Dynamic range  
SE  
Saturation exposure  
9V supply current  
5V supply current  
Total transfer efficiency  
Output impedance  
Offset level  
lx · s  
mA  
mA  
%
IVDD1  
IVDD2  
TTE  
ZO  
8.0  
5.0  
1.8  
92.0  
97.0  
600  
4.0  
VOS  
V
Note 7  
Notes)  
1. For the sensitivity test light is applied with a uniform intensity of illumination.  
2. PRNU is defined as indicated below. Ray incidence conditions are the same as for Note 1.  
(VMAX – VMIN)/2  
PRNU =  
× 100 [%]  
VAVE  
The maximum output is set to VMAX, the minimum output to VMIN and the average output to VAVE.  
3. Integration time is 10ms.  
4. VOUT = 500mV  
VSAT  
5. DR =  
VDRK  
When optical accumulated time is shorter, the dynamic range gets wider because dark voltage is in  
proportion to optical accumulated time.  
VSAT  
6. SE =  
R
7. Vos is defined as indicated below.  
D31  
D32  
VOS  
D33  
S1  
OS  
GND  
– 3 –  
ILX551A  
2
1
7 8 0 2  
9 3 D  
8 3 S  
7 3 S  
6 3 D  
5 3 D  
4 3 D  
8 4 0 2 S  
7 4 0 2 S  
6 4 0 2 S  
5 4 0 2 S  
4 S  
3 S  
2 S  
1 S  
3 3 D  
2 3 D  
1 3 D  
5 1 D  
4 1 D  
3 1 D  
2 1 D  
1 1 D  
6 D  
5 D  
4
3
2
4 D  
3 D  
2 D  
1
– 4 –  
ILX551A  
Fig. 2. φCLK, VOUT Timing  
t1  
t2  
φCLK  
t3  
t4  
t5  
VOUT  
t6  
Item  
Symbol  
Min.  
0
Typ.  
Max.  
Unit  
ns  
φCLK pulse rise/fall time  
t1, t2  
10  
50  
80  
75  
1
φCLK pulse duty  
40  
50  
30  
60  
%
φCLK – VOUT 1  
φCLK – VOUT 2  
t5  
110  
120  
ns  
t6  
ns  
1
100 × t3/(t3 + t4)  
Fig. 3. φROG, φCLK Timing  
φROG  
t8  
t9  
t10  
φCLK  
t7  
t11  
Item  
Symbol  
Min.  
500  
0
Typ.  
1000  
10  
Max.  
Unit  
ns  
φROG, φCLK pulse timing  
φROG pulse rise/fall time  
φROG pulse period  
t7, t11  
t8, t10  
t9  
ns  
500  
1000  
ns  
– 5 –  
ILX551A  
Example of Representative Characteristics  
Spectral sensitivity characteristics  
(Standard characteristics)  
1.0  
0.9  
Ta = 25°C  
0.8  
0.7  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0
400  
500  
600  
700  
800  
900  
1000  
Wavelength [nm]  
Dark signal voltage rate vs. Ambient temperature  
(Standard characteristics)  
VDD1, VDD2 supply current vs. Clock frequency  
(Standard characteristics)  
IVDD1  
IVDD2  
10  
5
10  
5
1
1
0.5  
0.5  
0.1  
0.1  
0.1M  
0
10  
20  
30  
40  
50  
60  
1M  
5M  
Ta – Ambient temperature [°C]  
Clock frequency [Hz]  
– 6 –  
ILX551A  
) D ( D N G  
C N  
G O R φ  
C N  
C N  
) D ( 2 D D V  
) D ( 2 D D V  
C N  
C N  
C N  
) A ( D N G  
C N  
C N  
K L C φ  
W S H S  
C N  
) A ( D N G  
) A ( 1 D D V  
) D ( 2 D D V  
) D ( 2 D D V  
C N  
T U O V  
– 7 –  
ILX551A  
Notes of Handling  
1) Static charge prevention  
CCD image sensors are easily damaged by static discharge. Before handling be sure to take the following  
protective measures.  
a) Either handle bare handed or use non chargeable gloves, clothes or material. Also use conductive shoes.  
b) When handling directly use an earth band.  
c) Install a conductive mat on the floor or working table to prevent the generation of static electricity.  
d) Ionized air is recommended for discharge when handling CCD image sensor.  
e) For the shipment of mounted substrates, use boxes treated for prevention of static charges.  
2) Notes on Handling CCD Cer-DIP Packages  
The following points should be observed when handling and installing cer DIP packages.  
a) Remain within the following limits when applying static load to the ceramic portion of the package:  
(1) Compressive strength: 39N/surface  
(Do not apply load more than 0.7mm inside the outer perimeter of the glass portion.)  
(2) Shearing strength: 29N/surface  
(3) Tensile strength: 29N/surface  
(4) Torsional strength: 0.9Nm  
29N  
29N  
39N  
0.9Nm  
Upper ceramic layer  
Lower ceramic layer  
Low-melting glass  
(2)  
(3)  
(4)  
(1)  
b) In addition, if a load is applied to the entire surface by a hard component, bending stress may be  
generated and the package may fracture, etc., depending on the flatness of the ceramic portion.  
Therefore, for installation, either use an elastic load, such as a spring plate, or an adhesive.  
c) Be aware that any of the following can cause the glass to crack: because the upper and lower ceramic  
layers are shielded by low-melting glass,  
(1) Applying repetitive bending stress to the external leads.  
(2) Applying heat to the external leads for an extended period of time with soldering iron.  
(3) Rapid cooling or heating.  
(4) Rapid cooling or impact to a limited portion of the low-melting glass with a small-tipped tool such as  
tweezers.  
(5) Prying the upper or lower ceramic layers away at a support point of the low-melting glass.  
Note that the preceding notes should also be observed when removing a component from a board after  
it has already been soldered.  
3) Soldering  
a) Make sure the package temperature does not exceed 80°C.  
b) Solder dipping in a mounting furnace causes damage to the glass and other defects. Use a grounded  
30W soldering iron and solder each pin in less then 2 seconds. For repairs and remount, cool sufficiently.  
c) To dismount an imaging device, do not use a solder suction equipment. When using an electric desoldering  
tool, ground the controller. For the control system, use a zero cross type.  
– 8 –  
ILX551A  
4) Dust and dirt protection  
a) Operate in clean environments.  
b) Do not either touch glass plates by hand or have any object come in contact with glass surfaces. Should  
dirt stick to a glass surface, blow it off with an air blower. (For dirt stuck through static electricity ionized  
air is recommended.)  
c) Clean with a cotton bud and ethyl alcohol if the glass surface is grease stained. Be careful not to scratch  
the glass.  
d) Keep in a case to protect from dust and dirt. To prevent dew condensation, preheat or precool when  
moving to a room with great temperature differences.  
5) Exposure to high temperatures or humidity will affect the characteristics. Accordingly avoid storage or  
usage in such conditions.  
6) CCD image sensors are precise optical equipment that should not be subject to mechanical shocks.  
– 9 –  
ILX551A  
° 9 o t ° 0  
5 . 0 ± 5 3 . 4  
5 6 . 3  
5 . 0 ± 0 . 0 1  
5 . 0 ± 0 . 5  
5 . 0 ± 0 . 4  
– 10 –  
Sony Corporation  

相关型号:

ILX551B

2048-pixel CCD Linear Sensor (B/W)
SONY

ILX553A

5150-pixel CCD Linear Sensor (B/W)
SONY

ILX553B

5150-pixel CCD Linear Sensor B W
SONY

ILX554

2048-pixel CCD Linear Sensor (B/W) for Single 5V Power Supply Bar-code Reader
SONY

ILX554A

2048-pixel CCD Linear Sensor (B/W) for Single 5V Power Supply Bar-code Reader
SONY

ILX554B

2048-pixel CCD Linear Sensor (B/W) for Single 5V Power Supply Bar-code Reader
SONY

ILX555K

10680 pixel 】 3 line CCD Linear Sensor (Color)
SONY

ILX558K

5340-pixel 】 3-line CCD Linear Sensor (Color)
SONY

ILX569K

5340-pixel x 6 line CCD Linear Sensor (Color)
SONY

ILX585K

pixel 】 6line CCD Linear Sensor (Color)
SONY

ILX703A

2048-pixel CCD Linear Image Sensor (B/W) with Shutter Function
SONY

ILX716K

3648 X 3pixel CCD Linear Sensor (Color)
SONY