C-13-2500C-TDFB3-SSC2 概述
2.5 Gbps Single Mode Transceiver 2.5 Gbps的单模收发器 光纤收发器
C-13-2500C-TDFB3-SSC2 规格参数
生命周期: | Active | Reach Compliance Code: | unknown |
风险等级: | 5.75 | Is Samacsys: | N |
主体宽度: | 25.4 mm | 主体高度: | 9.8 mm |
主体长度或直径: | 39.6 mm | 通信标准: | GR-468, OC-48, SONET, STM-16 |
连接类型: | SC CONNECTOR | 数据速率(接收): | 2500 Mbps |
数据速率(发送): | 2500 Mbps | 发射极/检测器类型: | LASER DIODE |
光纤设备类型: | TRANSCEIVER | 光纤类型: | SMF |
安装特点: | THROUGH HOLE MOUNT | 最高工作温度: | 70 °C |
最低工作温度: | 最大工作波长: | 1355 nm | |
最小工作波长: | 1280 nm | 标称工作波长: | 1310 nm |
标称光功率输出: | 0.562 mW | 灵敏度: | -20 dBm |
最大供电电压: | 3.5 V | 最小供电电压: | 3.1 V |
标称供电电压: | 3.3 V | 表面贴装: | NO |
Base Number Matches: | 1 |
C-13-2500C-TDFB3-SSC2 数据手册
通过下载C-13-2500C-TDFB3-SSC2数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载2.5 Gbps Single Mode Transceiver
C-1X-2500(C)-TDFB(3)-SSCX
Features
• SC Duplex Single Mode Transceiver
• Industry Standard 1x9 Footprint
• Complies with SONET OC-48 STM-16
• Single +3.3V / +5V Power Supply
• Operating Temperature Range 0℃ ~ +70℃
• CML Differential Data Inputs and Outputs
• PECL/LVPECL Signal Detection Output
[C-1X-2500-TDFB(3)-SSCX]
• TTL/LVTTL Signal Detection Output
[C-1X-2500C-TDFB(3)-SSCX]
• Wave Solderable and Aqueous Washable
• Uncooled laser diode with MQW structure
• Complies with Telcordia (Bellcore) GR-468-CORE
Applications
• STM 16/ OC-48, 2.5 Gigabit
Absolute Maximum Rating
Parameter
Symbol
Vcc
Min.
Max.
3.6
6
Unit
V
Note
Power Supply Voltage
Power Supply Voltage
Output Current
0
0
C-1X-2500(C)-TDFB3-SSCX
C-1X-2500(C)-TDFB-SSCX
Vcc
V
Iout
0
30
mA
ºC
ºC
ºC
Soldering Temperature
Operating Temperature
Storage Temperature
-
260
70
10 seconds on leads only
-
Topr
Tstg
0
-40
85
Recommended Operating Condition
Parameter
Symbol
Min.
3.1
4.75
0
Typ.
Max.
3.5
5.25
70
Unit
V
Power Supply Voltage 1
Power Supply Voltage 1
Operating Temperature (Case)
Data Rate
Vcc
Vcc
Topr
-
3.3
5
V
-
ºC
-
2488.32
-
Mbit/s
Note1: Please refer to ordering information
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS797-Dec0904
rev. A.0
1
2.5 Gbps Single Mode Transceiver
C-1X-2500(C)-TDFB(3)-SSCX
Transmitter Specifications (Optical)
Parameter
Symbol
Min
-5
Typical
Max
Unit
dBm
dBm
nm
Notes
C-1X-2500(C)-TDFB(3)-SSC2
C-1X-2500(C)-TDFB(3)-SSC4
C-13-2500(C)-TDFB(3)-SSCX
C-15-2500(C)-TDFB(3)-SSCX
-20 dB width
Po
Po
-
0
+5
1355
1580
1
Optical Transmit Power
Optical Transmit Power
Output center Wavelength
Output center Wavelength
Output Spectrum Width
Side Mode Suppression Ratio
Extinction Ratio
0
-
1310
1550
-
λ
1280
1500
-
λ
nm
∆λ
SMSR
ER
nm
30
35
-
dB
CW, Po=5mW
8.2
-
-
dB
Output Eye
Compliant with ITU recommendation G.957
Relative Intensity Noise
Total Jitter
RIN
TJ
-
-
-
-
-120
0.18
dB/Hz
ns
Measured with 223-1 PRBS with 72 ones and
72 zeros
Transmitter Specifications (Electrical)
Parameter
Symbol
ICC
IIL
Min
Typical
Max
Unit
Notes
Maximum current is specified at
Vcc= Maximum @ maximum temperature
-
-
260
mA
Power Supply Current
Data Input Current-Low
Data Input Current-High
Data Input Voltage
-350
-
-
-
-
-
350
-
µA
µA
mV
I
IH
V -VIL
IH
300
Peak-peak, single ended, AC coupled
Receiver Specifications (Optical)
Parameter
Sensitivity2
Symbol
Min
Typical
Max
-20
-
Unit
dBm
dBm
dBm
dBm
dB
Notes
-
-
0
-
-
-
-
-
-
Maximum Input Power
Signal Detect-Asserted
Signal Detect-Deasserted
Signal Detect-Hysteresis
Wavelength of Operation
Reflectance
Pin
Pa
Pd
-
-20
-
Measured on transition: low to high
Measured on transition: high to low
-38
1
-
1100
1600
-27
nm
dB
-10
Note 2: Measured with 223-1 PRBS, BER= 10
Receiver Specifications (Electrical)
Parameter
Symbol
Min
-
Typical
Max
100
900
0.5
-
Unit
mA
mV
V
Note
ICC
VOH -VOL
VSDL
-
-
-
-
The current excludes the output load current
Peak-peak, single-ended, AC-coupled
Power Supply Current
Data output Voltage
300
-
Signal Detect Output Voltage-Low
Signal Detect Output Voltage-High
C-1X-2500C-TDFB(3)-SSCX
C-1X-2500-TDFB(3)-SSCX
2.0
V
VSDH
Signal Detect Output Voltage-Low VSDL-Vcc
Signal Detect Output Voltage-High Vcc
-2.0
-1.1
-
-
-1.58
-0.74
V
V
VSDH-
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS797-Dec0904
rev. A.0
2
2.5 Gbps Single Mode Transceiver
C-1X-2500(C)-TDFB(3)-SSCX
Connection Diagram
Receiver Signal Ground
Receiver Data Out
1. (Rx GND)
2. (Rx +)
3. (Rx-)
NC
Receiver Data Out Bar
Signal Detect
4. (SD)
Receiver Power Supply
Transmitter Power Supply
Transmitter Data In Bar
Transmitter Data in
5. (Rx Vcc)
6. (Tx Vcc)
7. (TX-)
8. (TX+)
9. (Tx GND)
Top View
NC
Transmitter Signal Ground
PIN
Symbol
RxGND
RD+
Notes
Directly connect this pin to the receiver ground plane
See recommended circuit schematic
1
2
3
4
5
6
7
RD-
See recommended circuit schematic
SD
Active high on this indicates a received optical signal
DC power for the receiver section
RxVcc
TxVcc
TD-
DC power for the transmitter section
See recommended circuit schematic
8
TD+
See recommended circuit schematic
9
TxGND
Directly connect this pin to the transmitter ground plane
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS797-Dec0904
rev. A.0
3
2.5 Gbps Single Mode Transceiver
C-1X-2500(C)-TDFB(3)-SSCX
Recommended Circuit Schematic
C-1X-2500-TDFB(3)-SSCX
Rx Vcc
9 8 7 6 5 4 3 2
1
C5
R1
RD +
TD +
TD -
Z=50
!
!
Z=50
!
!
Z=50
Z=50
RD -
SD
Tx Vcc
Rx Vcc
R2
No internal
connection
No internal
connection
Transceiver
Top view
L1
Rx Vcc
C3
L2
C1
C2
Vcc
Notes +3.3V:
C1=C2=C5=0.1"F
C3=C4=10"F
L1=L2=1"H
R1=130!
Notes +5V:
C1=C2=C5=0.1"F
C3=C4=10"F
L1=L2=1"H
R1=82!
Tx Vcc
C4
R2=82!
R2=130!
C-1X-2500C-TDFB(3)-SSCX
9
8
7
6
5
4
3
2
1
RD +
TD +
TD -
Z=50!
Z=50!
Z=50!
Z=50!
RD -
SD
Tx Vcc
Rx Vcc
No internal
connection
No internal
connection
Transceiver
Top view
L1
Rx Vcc
Tx Vcc
Notes:
C3
L2
C1
C2
C1=C2=0.1"F
C3=C4=10"F
L1=L2=1"H
Vcc
C4
The split-loaded terminations for ECL signals need to be located at the input of devices receiving those ECL signals.
The power supply filtering is required for good EMI performance. Use short tracks from the inductor L1/L2 to the module Rx Vcc.
A GND plane under the module is required for good EMI and sensitivity performance.
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
LUMINENTOIC.COM
LUMNDS797-Dec0904
rev. A.0
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
4
2.5 Gbps Single Mode Transceiver
C-1X-2500(C)-TDFB(3)-SSCX
Package Diagram
SC Transceiver Assembly 9.8mm
Units in mm
Front View
Top View
Rear View
Side View
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS797-Dec0904
rev. A.0
5
2.5 Gbps Single Mode Transceiver
C-1X-2500(C)-TDFB(3)-SSCX
Ordering Information
Available Options:ꢀ
C-13-2500-TDFB-SSC4
C-13-2500-TDFB-SSC2
C-13-2500C-TDFB-SSC2
C-13-2500-TDFB3-SSC2
C-13-2500C-TDFB3-SSC2
C-15-2500-TDFB-SSC2
C-15-2500C-TDFB-SSC2
C-15-2500-TDFB3-SSC2
C-15-2500C-TDFB3-SSC2
C-13-2500C-TDFB-SSC4
C-13-2500-TDFB3-SSC4
C-13-2500C-TDFB3-SSC4
C-15-2500-TDFB-SSC4
C-15-2500C-TDFB-SSC4
C-15-2500-TDFB3-SSC4
C-15-2500C-TDFB3-SSC4
Part numbering Definition:
C - 1X - 2500(C) - TDFB(3) - S SC TxPower
• 13 = Wavelength 1310nm
15 = Wavelength 1550nm
• Communication protocol
(2.5 Gbps)
2500 = PECL Signal Detection Output
2500C = TTL Signal Detection Output
• TDFB = +5V Transceiver, DFB
TDFB3= +3.3V Transceier, DFB
• Single mode fiber
• Connector options
• Tx Power range
2 = -5 to 0 dBm
4 = 0 to +5 dBm
Warnings:
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow
guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notes:
IMPORTANT NOTICE!
All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance
of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are
given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warran-
ties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of
Sale for further warranty information.
LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual
property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes
no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this docu-
ment are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers
using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from
such use or sale.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any
actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact
LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current.
© LuminentOIC, Inc. 2003
All rights reserved
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS797-Dec0904
rev. A.0
6
C-13-2500C-TDFB3-SSC2 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
C-13-2500C-TDFB3-SSC4 | SOURCE | 2.5 Gbps Single Mode Transceiver | 获取价格 | |
C-13-622-F-SLC | SOURCE | 622 Mbps Single Mode SFF LC Transceiver | 获取价格 | |
C-13-622-F-SLC-55-G5 | SOURCE | 622 Mbps Single Mode SFF LC Transceiver | 获取价格 | |
C-13-622-F-SLC-G5 | SOURCE | 622 Mbps Single Mode SFF LC Transceiver | 获取价格 | |
C-13-622-F-SLC4 | SOURCE | 622 Mbps Single Mode SFF LC Transceiver | 获取价格 | |
C-13-622-F-SLC4A | SOURCE | 622 Mbps Single Mode SFF LC Transceiver | 获取价格 | |
C-13-622-F-SLCA | SOURCE | 622 Mbps Single Mode SFF LC Transceiver | 获取价格 | |
C-13-622-F-SLCA-55-G5 | SOURCE | 622 Mbps Single Mode SFF LC Transceiver | 获取价格 | |
C-13-622-F-SLCA-G5 | SOURCE | 622 Mbps Single Mode SFF LC Transceiver | 获取价格 | |
C-13-622-FDFB-SLC | SOURCE | 622 Mbps Single Mode SFF LC Transceiver | 获取价格 |
C-13-2500C-TDFB3-SSC2 相关文章
- 2024-09-20
- 6
- 2024-09-20
- 9
- 2024-09-20
- 8
- 2024-09-20
- 6