SFPD-GB-08-18-A [SOURCE]

Transceiver, 1250Mbps(Tx), 1250Mbps(Rx), Panel Mount;
SFPD-GB-08-18-A
型号: SFPD-GB-08-18-A
厂家: SOURCE PHOTONICS, INC.    SOURCE PHOTONICS, INC.
描述:

Transceiver, 1250Mbps(Tx), 1250Mbps(Rx), Panel Mount

文件: 总12页 (文件大小:206K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
P/N: SFPD-GB-xx-xx-A  
Gigabit Ethernet DWDM SFP Transceiver  
Features  
Available in all 100 GHz C-Band Wavelengths on the  
DWDM ITU Grid  
DWDM SFP MSA Compliant  
Cold Start Up Wavelength Compliance  
Low Power Dissipation < 1.3W Maximum  
-5ºC to 70ºC Operating Case Temperature  
IEEE 802.3ah Compliant  
Pluggable Into Existing Standard SFP Cages  
Diagnostic Performance Monitoring of Transmit Power,  
Receiver Power, Laser Bias, Module Temperature, Laser  
Temperature, APD Bias Voltage, TEC Current  
APD Based Receiver Sensitivity of –28dBm at 1.25Gb/s  
Long Reach 80km and 120km Versions Available  
Table 1 – General Operating  
Parameter  
Symbol  
Min.  
Typical  
Max.  
Unit  
Notes  
Supply Voltage  
Vcc  
ICC  
3.135  
-
3.3  
3.465  
375  
-
V
mA  
Total Current (BOL)  
-
Power Supply Noise Rejection  
Operating Temperature (Case)  
Storage Temperature  
Data Rate GbE  
PSR  
100  
-5  
-
mVp-p  
ºC  
1
T
op  
-
-
70  
85  
-
T
st  
-40  
-
ºC  
DR  
1250  
Mbps  
Note 1: 20Hz to 155MHz  
Table 2 – Transmitter Specifications (Optical)  
Parameter  
Optical Power  
Symbol  
Min.  
Typical  
Max.  
Unit  
Notes  
Pop  
Poff  
ER  
0
-
2
-
4
-45  
-
dBm  
dBm  
dB  
Average Launch Power Tx_Off  
Extinction Ratio  
8.2  
-
Eye Mask  
IEEE 802.3, SONET/SDH Compliant  
Optical Jitter Generation  
Optical Rise/Fall Time  
Jgen(pk-pk)  
-
-
0.07  
160  
-
UI  
ps  
t /t  
r f  
-
-
2
Δf  
Channel Spacing  
-
-
100  
GHz  
GHz  
nm  
Deviation From Central Frequency, EOL  
Spectral Width (20dB)  
-
-
-
-
-
-
±12  
0.3  
-
Δλ  
SMSR  
dp  
-
Side Mode Suppression Ratio  
Dispersion Penalty at Specified Distance  
Relative Intensity Noise  
Reflection Tolerance  
30  
-
dB  
2
dB  
3
4
RIN  
rp  
-
-135  
-
dB/Hz  
dB  
-24  
Note 2: 20%~80% values  
- 1 -  
DS-5605 Rev 0.0 2009-06-22  
P/N: SFPD-GB-xx-xx-A  
Gigabit Ethernet DWDM SFP Transceiver  
Note 3: Measured at BER of 1E-12, 1.25Gb/s, at eye center.  
For SFPD-GB-08/E08-xx-A, measured at 80km (1600ps/nm); for SFPD-GB-12/E12-xx-A, measured  
at 120km (2400ps/nm).  
Note 4: 2dB degradation of receiver sensitivity  
Table 3 – Transmitter Specifications (Electrical)  
Parameter  
Symbol  
Min.  
Typical  
Max.  
Unit  
Notes  
Input Differential Impedence  
PECL Single Ended Data Input Swing  
TxFault_Fault  
Rin  
Vin, p-p  
Vfault  
Vnormal  
Vd  
80  
250  
2
100  
120  
1200  
mV  
V
-
-
-
-
-
Vcc  
TxFault_Normal  
Vee  
2
Vee + 0.5  
Vcc  
V
TxDisable_Disable  
V
TxDisable_Enable  
Ven  
Vee  
Vee + 0.8  
V
Table 4 – Receiver Specifications (Optical)  
Parameter  
Receiver Power Low  
Symbol  
Min.  
Typical  
Max.  
Unit  
Notes  
Rsens,low  
-
-6  
-30  
-28  
dBm  
dBm  
dBm  
nm  
5
Receiver Power High  
Damage Threshold For Receiver  
Wavelength  
Rsens,high  
-
-
-
-
-
Pin, damage  
4
λ
1528  
1564  
-27  
-
Maximum Reflectance Of Receiver  
LOS Assert  
RX_r  
dB  
-
-
-
-38  
-
-
-
-
dBm  
dBm  
dB  
LOS De-Assert  
-28  
LOS Hysteresis  
0.5  
-
Note 5: At 10-12 BER, 1.25Gb/s, 1310nm to 1610nm received wavelength. At wavelength ranges of 1260nm to  
1310nm and 1610nm to 1620nm, maximum sensitivity penalty is 1dB  
Table 5 – Receiver Specifications (Electrical)  
Parameter  
Symbol  
Min.  
Typical  
Max.  
Unit  
Notes  
Single Ended Data Output Swing  
Data Output Rise Time  
Vout,p-p  
185  
-
-
-
800  
175  
175  
mV  
ps  
tr  
tf  
-
-
Data Output Fall Time  
ps  
- 2 -  
DS-5605 Rev 0.0 2009-06-22  
P/N: SFPD-GB-xx-xx-A  
Gigabit Ethernet DWDM SFP Transceiver  
Table 6 – Timing and Electrical  
Parameter  
Symbol  
Min.  
Typical  
Max.  
Unit  
Notes  
Tx Disable Negate Time  
Tx Disable Assert Time  
Time to Initialize After Reset of Tx  
Fault/INT in Normal Operation  
Start-up Time  
t_on  
t_off  
-
-
-
-
20  
20  
ms  
ms  
t_init  
-
-
300  
ms  
t_startup  
t_fault  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
90  
secs  
ms  
µs  
µs  
µs  
kHz  
V
Tx Fault/INT Assert Time  
Tx Disable to Reset  
50  
-
t_reset  
10  
-
LOS Assert Time  
t_loss_on  
t_loss_off  
f_serial_clock  
Rx_LOSH  
RX_LOSL  
VLOS fault  
VLOS normal  
VH  
100  
LOS De-Assert Time  
-
100  
Serial ID Clock Rate  
-
100  
RX_LOS Voltage (High)  
RX_LOS Voltage (Low)  
LOS Output Voltage-Fault  
LOS Output Voltage-Normal  
MOD_DEF (0:2)-High  
MOD_DEF (0:2)-Low  
2
-
-
0.8  
V
2
Vcc  
V
Vee  
2
Vee + 0.55  
Vcc  
V
V
VL  
Vee  
Vee + 0.5  
V
Table 7 – Diagnostics  
Parameter  
Range  
Accuracy  
Unit  
Notes  
Temperature  
Voltage  
-5 to 70  
0 to Vcc  
0 to 120  
0 to 4  
±3  
0.1  
5
ºC  
V
Bias Current  
Tx Power  
Rx Power  
mA  
dBm  
dBm  
mA  
ºC  
±2  
-28 to -6  
±2  
TEC Current  
-1200 to 1200  
20 to 70  
±60  
±0.25  
TEC Temperature  
6
Note 6: Relative accuracy. Absolute accuracy is ±3ºC  
- 3 -  
DS-5605 Rev 0.0 2009-06-22  
P/N: SFPD-GB-xx-xx-A  
Gigabit Ethernet DWDM SFP Transceiver  
Table 8 –λ Wavelength Ordering  
SFPD-GB-08/12-xx-A  
See table below for “xx” values  
ITU Channel/Product  
Frequency (THz)  
Code  
ITU Channel/Product  
Wavelength (nm)  
Frequency (THz)  
Wavelength (nm)  
Code  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
191.5  
191.6  
191.7  
191.8  
191.9  
192.0  
192.1  
192.2  
192.3  
192.4  
192.5  
192.6  
192.7  
192.8  
192.9  
193.0  
193.1  
193.2  
193.3  
193.4  
193.5  
193.6  
193.7  
193.8  
1565.495  
1564.678  
1563.863  
1563.047  
1562.233  
1561.419  
1560.606  
1559.794  
1558.983  
1558.173  
1557.363  
1556.555  
1555.747  
1554.940  
1554.134  
1553.329  
1552.524  
1551.721  
1550.918  
1550.116  
1549.315  
1548.515  
1547.715  
1546.917  
193.9  
194.0  
194.1  
194.2  
194.3  
194.4  
194.5  
194.6  
194.7  
194.8  
194.9  
195.0  
195.1  
195.2  
195.3  
195.4  
195.5  
195.6  
195.7  
195.8  
195.9  
1546.119  
1545.322  
1544.526  
1543.730  
1542.936  
1542.142  
1541.349  
1540.557  
1539.766  
1538.976  
1538.186  
1537.397  
1536.609  
1535.822  
1535.036  
1534.250  
1533.465  
1532.681  
1531.898  
1531.116  
1530.334  
60  
61  
196.0  
196.1  
1529.553  
1528.773  
- 4 -  
DS-5605 Rev 0.0 2009-06-22  
P/N: SFPD-GB-xx-xx-A  
Gigabit Ethernet DWDM SFP Transceiver  
Table 9 – EEPROM Serial ID (A0h)  
Name of Field  
Description of Field  
Address  
Hex  
0B  
24  
07  
00  
00  
00  
02  
00  
00  
00  
00  
ASCII  
Identifier  
0
1
Type of serial transceiver  
Extended identifier of type of serial transceiver  
Code for connector type  
Ext. Identifier  
Connector  
2
3
4
5
Code for electronic compatibility or optical  
compatibility  
6
Transceiver  
7
8
9
10  
Encoding  
Code for serial encoding algorithm  
11  
01  
12  
13  
14  
0D  
00  
BR.Nominal  
Nominal bit rate, units of 100 MBits/sec.  
Link length supported for 9/125µm,  
Length (9µm,km)  
Max Temp  
50/78  
units of km  
Maximum operating case temperature  
15  
16  
46  
(see text for encoding)  
Minimum operating case temperature in ºC  
(see text for encoding)  
Min Temp  
FB  
17  
18  
6C  
00  
Max Supply Current  
Reserved  
Maximum supply current in units of 4mA  
Reserved  
Channel spacing and  
Tuning  
Channel spacing compatibility and number  
of ITU channels supported  
19  
41  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
53  
4F  
55  
52  
43  
45  
50  
48  
4F  
54  
4F  
4E  
49  
43  
53  
20  
S
O
U
R
C
E
P
H
O
T
O
N
I
C
S
[SPACE]  
- 5 -  
DS-5605 Rev 0.0 2009-06-22  
P/N: SFPD-GB-xx-xx-A  
Gigabit Ethernet DWDM SFP Transceiver  
Table 9 – EEPROM Serial ID (A0h)  
Name of Field  
Description of Field  
Address  
Hex  
ASCII  
Optional features  
36  
00  
Implemented Optional DWDM Features  
37  
38  
39  
00  
1F  
22  
SFP vendor IEEE company ID for  
Source Photonics Inc.  
Vendor OUI  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
53  
46  
50  
44  
47  
42  
xx  
xx  
xx  
xx  
41  
20  
20  
20  
20  
20  
S
F
P
D
G
B
x
Part number in ASCII, e.g.  
SFPDGBxxxxA  
x
Vendor P/N  
x
x
A
[SPACE]  
[SPACE]  
[SPACE]  
[SPACE]  
[SPACE]  
56  
57  
58  
59  
xx  
20  
20  
20  
x
Revision level for part number provide by  
vendor (ASCII)  
[Space]  
[Space]  
[Space]  
Vendor Rev.  
60  
61  
62  
xx  
xx  
xx  
Wavelength  
Wavelength  
Laser wavelength (in nm)  
Laser wavelength (fractional part in units of 10pm)  
Check code for Base ID Fields  
(addresses 0 to 62)  
CC_BASE  
Options  
63  
xx  
64  
65  
00  
1A  
Indicates which optional transceiver signals  
are implemented  
- 6 -  
DS-5605 Rev 0.0 2009-06-22  
P/N: SFPD-GB-xx-xx-A  
Gigabit Ethernet DWDM SFP Transceiver  
Table 9 – EEPROM Serial ID (A0h)  
Name of Field  
Description of Field  
Address  
Hex  
ASCII  
BR, max  
BR, min  
Upper bit rate margin, unit of %  
Lower bit rate margin, unit of %  
66  
00  
67  
00  
xx  
xx  
Vendor S/N  
Date Code  
Serial number  
68-83  
84-91  
Vendor’s manufacturing date code  
Indicates which type of diagnostic monitoring  
is implemented in the transceiver  
Diagnostic Monitoring  
Type  
92  
93  
94  
68  
F0  
01  
Indicates which optional enhanced features  
are implemented in the transceiver  
Indicates which revision of SFF-8472 the  
transceiver complies with  
Enhanced Options  
SFF-8472 Compliance  
Check code for Extended ID Fields  
(addresses 64 to 94)  
CC_EXT  
95  
xx  
xx  
Vendor Specific  
Vendor Specific EEPROM  
96-127  
- 7 -  
DS-5605 Rev 0.0 2009-06-22  
P/N: SFPD-GB-xx-xx-A  
Gigabit Ethernet DWDM SFP Transceiver  
Table 10 – Pin Definitions  
Pin  
1
Unit  
Notes  
VeeT  
TX GND  
2
TX_FAULT/INT  
TX_DISABLE  
MOD_DEF2  
MOD_DEF1  
MOD_DEF0  
NC  
Open Collector  
Internally Pulled High  
Serial Data Input  
Serial Clock Input  
Internally Grounded  
Not Connected  
Open Collector  
RX Ground  
3
4
5
6
7
8
LOS  
9
VeeR  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
VeeR  
RX Ground  
VeeR  
RX Ground  
RXD-  
RX Data Negative  
RX Data Positive  
RX GND  
RXD+  
VeeR  
VCCR  
RX Power  
VCCT  
TX Power  
VeeT  
TX GND  
TXD+  
TX Data Positive  
TX Data Negative  
TX GND  
TXD-  
VeeT  
- 8 -  
DS-5605 Rev 0.0 2009-06-22  
P/N: SFPD-GB-xx-xx-A  
Gigabit Ethernet DWDM SFP Transceiver  
Recommended Interface Circuit  
1μH  
Vcc  
.01μF  
10μF  
0.1μF  
1μH  
VccT  
Protocol IC  
SourcePhotonics  
SFP  
R1  
10KΩ  
TX_DISABLE  
TX_DISABLE  
TX_FAULT  
TD +  
Laser Driver  
TX_FAULT  
.01μF  
SerDes  
100Ω  
TD -  
VCC  
T
.01μF  
VCCR  
10μF  
0.1μF  
Receiver Amplifier  
.01μF  
.01μF  
RD +  
RD -  
100Ω  
RX_LOS  
RX_LOS  
Vcc  
Vee  
R
R1  
EEPROM  
R1 R1 R1  
MOD_DEF 2  
MOD_DEF 1  
MOD_DEF 0  
R1=4.7K to 10K Ω  
- 9 -  
DS-5605 Rev 0.0 2009-06-22  
P/N: SFPD-GB-xx-xx-A  
Gigabit Ethernet DWDM SFP Transceiver  
Mechanical Diagram  
Units in mm  
- 10 -  
DS-5605 Rev 0.0 2009-06-22  
P/N: SFPD-GB-xx-xx-A  
Gigabit Ethernet DWDM SFP Transceiver  
Order Information  
Table 11 – Order Information  
Part No.  
SFPD-GB-08-xx-A  
SFPD-GB-12-xx-A  
Part Numbering Definition:  
SFPD - GB - Reach - ITU Channel - Revision  
SFPD = DWDM SFP  
Data Rate  
GB = Gigabit Ethernet  
08 = 80km, 12 = 120km  
xx = 15 to 61  
A = Design Revision  
- 11 -  
DS-5605 Rev 0.0 2009-06-22  
P/N: SFPD-GB-xx-xx-A  
Gigabit Ethernet DWDM SFP Transceiver  
Warnings  
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static  
free environment is highly recommended. Follow guidelines according to proper ESD procedures.  
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or  
indirect radiation.  
Legal Notice  
IMPORTANT NOTICE!  
All information contained in this document is subject to change without notice, at Source Photonics’ sole and  
absolute discretion. Source Photonics warrants performance of its products to current specifications only in  
accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary”  
are given to describe components only, and Source Photonics expressly disclaims any and all warranties for said  
products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular  
purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for  
further warranty information.  
Source Photonics assumes no liability for applications assistance, customer product design, software performance,  
or infringement of patents, services, or intellectual property described herein. No license, either express or implied,  
is granted under any patent right, copyright, or intellectual property right, and Source Photonics makes no  
representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual  
property rights. Products described in this document are NOT intended for use in implantation or other life support  
applications where malfunction may result in injury or death to persons. Source Photonics customers using or  
selling products for use in such applications do so at their own risk and agree to fully defend and indemnify Source  
Photonics for any damages resulting from such use or sale.  
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees  
that Source Photonics is not liable for any actual, consequential, exemplary, or other damages arising directly or  
indirectly from any use of the information contained in this document. Customer must contact Source Photonics to  
obtain the latest version of this publication to verify, before placing any order, that the information contained herein is  
current.  
Contact  
U.S.A. Headquarters  
20550 Nordhoff Street  
Chatsworth, CA 91311  
USA  
China  
Taiwan  
Building #2&5, WestExportProcessingZone  
No. 8 Kexin Road, Hi-Tech Zone  
Chengdu, 611731, China  
Tel: +86-28-8795-8788  
9F, No 81, Shui Lee Rd.  
Hsinchu, 300, Taiwan  
R.O.C.  
Tel: +1-818-773-9044  
Fax: +1-818-773-0261  
sales@sourcephotonics.com  
Tel: +886-3-5169222  
Fax: +886-3-5169213  
sales@sourcephotonics.com.tw  
Fax: +86-28-8795-8789  
sales@sourcephotonics.com.cn  
© Copyright Source Photonics, Inc. 2007~2008  
All rights reserved  
- 12 -  
DS-5605 Rev 0.0 2009-06-22  

相关型号:

SFPD-GB-08-20-A

Transceiver, 1250Mbps(Tx), 1250Mbps(Rx), Panel Mount
SOURCE

SFPD-GB-08-25-A

Transceiver, 1250Mbps(Tx), 1250Mbps(Rx), Panel Mount
SOURCE

SFPD-GB-08-31-A

Transceiver, 1250Mbps(Tx), 1250Mbps(Rx), Panel Mount
SOURCE

SFPD-GB-08-33-A

Transceiver, 1250Mbps(Tx), 1250Mbps(Rx), Panel Mount
SOURCE

SFPD-GB-08-35-A

Transceiver, 1250Mbps(Tx), 1250Mbps(Rx), Panel Mount
SOURCE

SFPD-GB-08-36-A

Transceiver, 1250Mbps(Tx), 1250Mbps(Rx), Panel Mount
SOURCE

SFPD-GB-08-38-A

Transceiver, 1250Mbps(Tx), 1250Mbps(Rx), Panel Mount
SOURCE

SFPD-GB-08-39-A

Transceiver, 1250Mbps(Tx), 1250Mbps(Rx), Panel Mount
SOURCE

SFPD-GB-08-44-A

Transceiver, 1250Mbps(Tx), 1250Mbps(Rx), Panel Mount
SOURCE

SFPD-GB-08-45-A

Transceiver, 1250Mbps(Tx), 1250Mbps(Rx), Panel Mount
SOURCE

SFPD-GB-08-47-A

Transceiver, 1250Mbps(Tx), 1250Mbps(Rx), Panel Mount
SOURCE

SFPD-GB-08-50-A

Transceiver, 1250Mbps(Tx), 1250Mbps(Rx), Panel Mount
SOURCE