SFP Bi-Directional Transceiver
SPL-35-GB-EBX
Features
• Compatible with IEEE 802.3ah, 1000Base BX
• Simplex LC Connector
• Digital Diagnostic SFF-8472 Compliant
• SFP MSA SFF-8074i Compliant
• 13dB Minimum Power Budget
• 20 km Minimum Reach
• Single 3.3V Supply
• 1310nm FP Laser
• Telcordia GR-468 Compliant
• Color coded bail latch tube: Blue
• RoHS-5/6 compliance produit (lead exemption)
General Operation
Parameter
Symbol
Vcc
Min.
3.135
-
Typ.
Max.
3.465
300
-
Unit
V
Supply Voltage
3.3
Total Current
ICC
-
mA
mVp-p
ºC
Power Supply Noise Rejection
Operating Case Temperature (-Cxx)
Operating Case Temperature (-Txx)
Storage Temperature
Data Rate
100
-5
-
Topr
Topr
Tstg
DR
-
70
-40
-40
-
-
-
85
ºC
85
ºC
1250
-
Mbps
Transmitter Specifications (Optical)
Parameter
Symbol
Pop
Min
Typical
Max
Unit
dBm
dB
-7
-
-4
-45
-
0
Optical Power
XT
-40
Optical Crosstalk
Average Launch Power (Tx:Off)
Extinction Ratio
Poff
-
-45
dBm
dB
ER
6
-
-
IEEE 802.3ah
260
Eye Mask
Optical Rise Time (20% to 80% values)
Optical Fall Time (20% to 80% values)
Mean Wavelength
tr
tf
-
-
ps
ps
-
-
260
λ
1260
1310
1360
3.5
nm
nm
dB/Hz
dB
Spectral Width (RMS)
σ
-
-
-
-
-
-
-
-
Relative Intensity Noise
Transmitter Reflectance
Reflection Tolerance
RIN
-
-120
-12
rp
12
dB
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1509-Oct3106
Rev A.1
1
SFP Bi-Directional Transceiver
SPL-35-GB-EBX
Transmitter Specifications (Electrical)
Parameter
Symbol
Rin
Min
80
250
2
Typical
Max
120
Unit
Ω
Input Differential Impedence
PECL Single-Ended Data Input Swing
TxFault_Fault
100
Vin, p-p
Vfault
Vnormal
Vd
-
-
-
-
-
1200
mV
V
Vcc
TxFault_Normal
Vee
2
Vee + 0.5
Vcc
V
TxDisable_Disable
V
TxDisable_Enable
Ven
Vee
Vee + 0.8
V
Receiver Specifications (Optical)
Parameter
Receiver Power Lowa
Receiver Power Higha
Damage Threshold for Receiver
Wavelength
Symbol
Min
-
Typical
Max
Unit
dBm
dBm
dBm
nm
Rsens,low
-22
-20
Rsens,high
-3
-
-
-
-
-
Pin, damage
0
-
1600
-
λ
1500
-45
LOS Assert
-
dBm
LOS De-Assert
-
-
-
-
0.5
-
-
-
-
-20
-
dBm
dB
LOS Hysteresis
Receiver Reflectance
-12
dB
a) Measured at 10-12 BER, PRBS 27-1, 6dB ER
Receiver Specifications (Electrical)
Parameter
Symbol
Min
Typical
Max
800
260
260
Unit
mV
ps
Vout,p-p
185
-
-
-
PECL Single-Ended Data Output Swing
Data Output Rise Time
tr
tf
-
-
Data Output Fall Time
ps
Timing and Electrical
Parameter
Symbol
t_on
Min
Typical
Max
1
Unit
ms
µs
-
-
-
-
-
-
-
-
Tx Disable Negate Time
t_off
10
Tx Disable Assert Time
Time to Initialize, Including Reset of Tx Fault
Tx Fault Assert Time
t_init
300
100
ms
µs
t_fault
Tx Disable to Reset
t_reset
t_loss_on
t_loss_off
f_serial_clock
Rx_LOSH
10
-
-
-
-
-
-
-
-
-
-
100
100
100
-
µs
µs
µs
KHz
V
LOS Assert Time
LOS De-Assert Time
Serial ID Clock Rate
RX_LOS Voltage (High)
RX_LOS Voltage (Low)
LOS Output Voltage-Fault
LOS Output Voltage-Normal
-
-
2
RX_LOSL
-
0.8
V
VLOS fault
VLOS normal
2
Vcc
V
Vee
Vee + 0.5
V
MOD_DEF (0:2)-High
MOD_DEF (0:2)-Low
Vh
VI
2
-
-
V
V
Vcc
Vee
Vee + 0.5
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1509-Oct3106
Rev A.1
2
SFP Bi-Directional Transceiver
SPL-35-GB-EBX
Diagnostics
Parameter
Range
Accuracy
Unit
ºC
Calibration Bit Value
Formula
Temperature (-TDA) -40 to 85
±3
±3
.1
Internal
Internal
Internal
External
1/256 C
1/256 C
100µV
-
Tc(C) = Tad(16 bit signed twos complement)/256
Tc(C) = Tad(16 bit signed twos complement)/256
V(Volts) = Vad(16 bit unsigned integer)*0.1
I(mA) = Islope * Iad(16 bit unsigned integer)+Ioffset
Temperature(-CDA)
Voltage
-5 to 70
0 to Vcc
0 to 120
ºC
V
Bias Current
5
mA
Tx_PWR(µW) = Tx_PWRslope*Tx_PWRad(16 bit unsigned
integer)+Tx_PWRoffset
Tx Power
Rx Power
-7 to 0
±3
±3
dBm
dBm
External
External
-
-
-20 to -3
Rx_PWR(µW) = A0+A1*x+A2*x^2+A3*x^3+A4*x^4
Pinout Definitions
Pin
Function
Notes
V
T
TX GND
Open Collector
Internally Pulled High
Serial Data Input
Serial Clock Input
Internally Grounded
Not Connected
Open Collector
RX Ground
1
2
ee
TX_FAULT
TX_DISABLE
MOD_DEF2
MOD_DEF1
MOD_DEF0
NC
3
4
5
6
7
8
LOS
9
V
V
V
R
R
R
ee
ee
ee
10
11
12
13
14
15
16
17
18
19
20
RX Ground
RX Ground
RXD-
RX Data Negative
RX Data Positive
RX GND
RXD+
V
R
ee
V
V
R
RX Power
CC
CC
T
TX Power
V
T
TX GND
ee
TXD+
TXD-
TX Data Positive
TX Data Negative
TX GND
V
T
ee
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1509-Oct3106
Rev A.1
3
SFP Bi-Directional Transceiver
SPL-35-GB-EBX
EEPROM Serial ID
Name of Field
Discription of Field
Address
20
Hex
4C
55
4D
49
4E
ASCII
L
U
M
I
21
22
23
24
N
E
SFP Vendor name (ASCII)
25
45
4E
Vendor Name
26
N
T
27
54
4F
28
O
I
29
49
43
30
C
37
38
39
00
06
B5
Vendor OUI
IEEE vendor OUI code for Luminent Inc.
40
41
42
43
44
45
46
47
48
49
53
50
4C
33
35
47
42
45
42
58
S
p
L
3
5
G
B
E
Part number in ASCII, e.g.
SPL-35-GB-EBX
Vendor P/N
B
X
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1509-Oct3106
Rev A.1
4
SFP Bi-Directional Transceiver
SPL-35-GB-EBX
Mechanicals
Units in mm (inches)
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1509-Oct3106
Rev A.1
5
SFP Bi-Directional Transceiver
SPL-35-GB-EBX
Suggested Transceiver Interface
1�H
Vcc
1�H
10�F
0.1�F
VCCT
.01�F
Protocol IC
LuminentOIC
SFP
R1
10Kꢀ
TX_DISABLE
TX_DISABLE
TX_FAULT
TD +
Laser Driver
TX_FAULT
.01�F
SerDes
100ꢀ
TD -
.01�F
VEET
VCCR
0.1�F
RD +
10�F
Receiver Amplifier
.01�F
.01�F
100ꢀ
RD -
RX_LOS
VEER
RX_LOS
Vcc
R
EEPROM
1
R1
R1
R1
MOD_DEF 2
MOD_DEF 1
MOD_DEF 0
R1=4.7K to 10Kꢀ
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1509-Oct3106
Rev A.1
6
SFP Bi-Directional Transceiver
SPL-35-GB-EBX
Ordering Information
Available Options:ꢀ
SPL-35-GB-EBX-CNA
SPL-35-GB-EBX-TNA
SPL-35-GB-EBX-CDA
SPL-35-GB-EBX-TDA
Part numbering Definition:
SPL - 35 - GB - EBX - Temperature Diagnostic Revision
• SPL = LC connector
• Wavelength
35 = Tx 1310nm/Rx 1550nm
• Data Rate
GB = Gigabit Ethernet
• Standard
EBX = 20 km reach
• Operatating Temperature
C= Commercial temperature (-5 to 70ºC)
T= Industrial temperature (-40 to 85ºC)
• D = Digital Diagnostic
N = No Digital Diagnostic
• Revision
A=RoHS 5/6-compliant product (lead exemption)
Warnings:
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow
guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notes:
IMPORTANT NOTICE!
All information contained in this document is subject to change without notice, at Luminent’s sole and absolute discretion. Luminent warrants performance of its
products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to
describe components only, and Luminent expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties
of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further
warranty information.
Luminent assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property
described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and Luminent makes no representa-
tions or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT
intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. Luminent customers using or selling
products for use in such applications do so at their own risk and agree to fully defend and indemnify Luminent for any damages resulting from such use or sale.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that Luminent is not liable for any actual,
consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact
Luminent to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current.
© Luminent, Inc. 2003
All rights reserved
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1509-Oct3106
Rev A.1
7
相关型号:
SPL-43-GB-BD-CDC
Transceiver, 1260nm Min, 1360nm Max, 1250Mbps(Tx), 1250Mbps(Rx), LC Connector, Panel Mount, ROHS COMPLIANT PACKAGE-20
SOURCE
SPL-43-GB-BD-CDFF
Transceiver, 1480nm Min, 1500nm Max, 1250Mbps(Tx), 1250Mbps(Rx), LC Connector, Surface Mount, ROHS COMPLIANT PACKAGE
SOURCE
SPL-43-GB-BD-CNC
Transceiver, 1260nm Min, 1360nm Max, 1250Mbps(Tx), 1250Mbps(Rx), LC Connector, Panel Mount, ROHS COMPLIANT PACKAGE-20
SOURCE
SPL-43-GB-BD-EDFF
Transceiver, 1480nm Min, 1500nm Max, 1250Mbps(Tx), 1250Mbps(Rx), LC Connector, Surface Mount, ROHS COMPLIANT PACKAGE
SOURCE
©2020 ICPDF网 联系我们和版权申明