SPL-53-DR-IR2-CNA [SOURCE]
SFP Bi-Directional Transceiver Preliminary; SFP双向收发器的初步型号: | SPL-53-DR-IR2-CNA |
厂家: | SOURCE PHOTONICS, INC. |
描述: | SFP Bi-Directional Transceiver Preliminary |
文件: | 总7页 (文件大小:519K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SFP Bi-Directional Transceiver
Preliminary
SPL-53-DR-IR2
Features
• Compliant with OC-3/STM-1 and OC-12/STM-4 Standards
• Simplex LC connector
• Single 3.3 V supply
• 40 km reach
• 25 dB Minimum Link Budget
• 1550nm DFB Laser
• Commercial temperature available (-Cxx)
• Industrial temperature available (-Txx)
• SFP MSA SFF-8074i compliant
• Telcordia GR-468 compliant
• Digital Diagnostic SFF-8472 compliant
• Color coded bail latch: Yellow
• RoHS compliant (lead free soldered)
General operating
Parameter
Symbol
Vcc
Min.
Typical
Max.
Unit
V
Supply Voltage
3.135
3.3
3.465
Total Current
Icc
-
100
-5
-40
-40
-
-
300
-
mA
Power Supply Noise Rejectiona
Operating Temperature (-Cxx)
Operating Temperature (-Txx)
Storage Temperature
Data Rate OC-3/STM-1
Data Rate OC-12/STM-4
Data Rate Fast Ethernet
PSR
Top
Top
Tst
-
-
mVp-p
ºC
70
85
85
-
-
ºC
-
ºC
DR
155
622
125
Mbps
Mbps
Mbps
DR
-
-
DR
-
-
a) 20Hz to 155MHz
Transmitter Specifications
Parameter
Symbol
Min
-3
Typical
Max
+2
-45
-
Unit
dBm
dBm
dB
-0.5
P
Optical Power
OP
Average Launch Power Of Off Tx
Extinction Ratio
-
-
-
P
Off
ER
10
Eye Mask
IEEE 802.3 and SONET/SDH Compliant
Optical Rise Timeb
tr
tf
-
-
500
500
1580
1
ps
ps
Optical Fall Timeb
-
Mean Wavelength
λ
1480
-
nm
nm
dB
Spectral Width (20dB)
Dispersion Penalty (at 40 Km)
Relative Intensity Noise
Optical Crosstalk
∆λ
-
-
-
0.5
1
RIN
XT
-
-
-
-
-
-120
-45
-
dB/Hz
dB
-
Side Mode Suppression Ratio
Reflectance Tolerance
SMSR
rp
30
-24
dB
-
dB
b) 20%-80% values
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1702-Apr3007
Rev 0.1
1
SFP Bi-Directional Transceiver
Preliminary
SPL-53-DR-IR2
Transmitter Specifications (Electical)
Parameter
Symbol
Rin
Min
80
250
2
Typical
Max
120
Unit
Ω
100
Input Differential Impedence
PECL Single Ended Data Input Swing
TxFault_Fault
Vin,p-p
Vfault
-
-
-
-
-
1200
Vcc
mV
V
TxFault_Normal
Vnormal
Vee
2
Vee+0.5
Vcc
V
TxDisable_Disable
V
Vd
TxDisable_Enable
Vee
Vee+0.8
V
Ven
Receiver Specifications
Parameter
Symbol
Rsens,low
Rsens,high
Pin,damage
λ
Min
Typical
Max
-28
-
Unit
dBm
dBm
dBm
nm
Receive Power Lowc
Receive Power Highc
Damage Threshold For Receiver
Wavelength
-
-8
-30
-
-
-
-
-
-
-
-
0
1260
-38
-
1360
-
LOS Assert
dBm
dBm
dB
LOS De-assert
-28
-
LOS Hysteresis
0.5
-
Receiver Reflectance
-
-12
dB
c) at 10-12 BER, FE unbalanced pattern, and 10-10 BER, 155.52 Mb/s & 622.08 Mb/s
Electrical Output
Parameter
Symbol
Min
Typical
Max
800
500
500
Unit
mV
ps
Vout, p-p
185
-
-
-
PECL Single Ended Data Output Swing
tr
tf
-
-
Data Output Rise Time
Data Output Fall Time
ps
Timing and Electrical
Parameter
Symbol
Min
Typical
Max
1
Unit
ms
µs
ms
µs
µs
µs
µs
KHz
V
t_on
t_off
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Tx Disable Negate Time
Tx Disable Assert Time
Time To Initialize, Including Reset Of Tx Fault
Tx Fault Assert Time
10
t_init
-
300
100
-
t_fault
-
Tx Disable To Reset
t_reset
10
-
Los Assert Time
t_loss_on
t_loss_off
f_serial_clock
100
100
100
-
Los De-assert Time
-
Serial ID Clock Rate
-
RX_LOS Voltage (High)
RX_LOS Voltage (Low)
LOS Output Voltage-Fault
LOS Output Voltage-Normal
MOD_DEF (0:2)-High
2
-
0.8
V
VLOS fault
2
Vcc
V
VLOSnormal
Vee
2
Vee+0.5
Vcc
V
Vh
Vl
V
MOD_DEF (0:2)-LOW
Vee
Vee+0.5
V
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1702-Apr3007
Rev 0.1
2
SFP Bi-Directional Transceiver
Preliminary
SPL-53-DR-IR2
Diagnostics
Range Accuracy Unit Calibration Bit value
Formula
Parameter
-5 to 70
±3
±3
0.1
5
ºC
ºC
V
Internal
Internal
Internal
External
1/256 C
1/256 C
100 µV
Tc(C)=Tad(16 bit signed twos complement)/256
Tc(C)=Tad(16 bit signed twos complement)/256
V(Volts)=Vad(16 bit unsigned integer)*0.1
I(mA)=Islope*Iad(16 bit unsigned integer)+Ioffset
Temperature (-Cxx)
Temperature (-Txx)
Voltage
-40 to 85
0 to V
cc
Bias current
0 to 120
-3 to +2
-28 to -8
mA
0.002mA
TX_PWR(µW)=TX_PWRslope*TX_PWRad(16 bit unsigned integer
+TX_PWRoffset
TX Power
RX Power
±2dB
±2dB
dBm
dBm
External
External
0.1 µw
0.1 µw
RX_PWR(µW)=A0+A1*x+A2*x^2+A3*x^3+A4*x^4
EEPROM Serial ID
Name of Field
Description of Field
Address
20
Hex
4C
55
4D
49
4E
ASCII
L
U
M
I
21
22
23
24
N
E
SFP Vendor name(ASCII)
25
45
4E
Vendor Name
26
N
T
27
54
4F
28
O
I
29
49
43
30
C
37
38
39
00
06
B5
Vendor OUI
IEEE vendor OUI code for LuminentOIC Inc.
40
41
42
43
44
45
46
47
48
49
50
51
52
53
50
4C
35
33
44
52
49
52
32
43
44
41
S
P
L
5
3
D
R
I
Part number in ASCII, e.g.
SPL-53-DR-IR2-CDA
Vendor PN
R
2
C
D
A
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1702-Apr3007
Rev 0.1
3
SFP Bi-Directional Transceiver
Preliminary
SPL-53-DR-IR2
Function
Notes
TX Ground
Pin
1
VeeT
Open Collector
Internally Pulled High
Serial Data Input
Serial Clock Input
Internally Grounded
Not Connected
Open Collector
RX Ground
2
TX_FAULT
TX_DISABLE
MOD_DEF2
MOD_DEF1
MOD_DEF0
NC
3
4
5
6
7
8
LOS
VeeR
9
VeeR
VeeR
RX Ground
10
11
12
13
14
RX Ground
RX Data Negative
RX Data Positive
RX Ground
RXD-
RXD+
VeeR
VccR
RX Power
15
VccT
VeeT
TX Power
TX Ground
16
17
18
19
20
TXD+
TXD-
VeeT
TX Data Positive
TX Data Negative
TX Ground
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1702-Apr3007
Rev 0.1
4
SFP Bi-Directional Transceiver
Preliminary
SPL-53-DR-IR2
Outline drawing
Units in mm (inches)
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1702-Apr3007
Rev 0.1
5
SFP Bi-Directional Transceiver
Preliminary
SPL-53-DR-IR2
Suggested Transceiver Interface
1�H
Vcc
1�H
10�F
0.1�F
VCCT
.01�F
Protocol IC
LuminentOIC
SFP
R1
10Kꢀ
TX_DISABLE
TX_DISABLE
TX_FAULT
TD +
Laser Driver
TX_FAULT
.01�F
SerDes
100ꢀ
TD -
.01�F
VEET
VCCR
0.1�F
RD +
10�F
Receiver Amplifier
.01�F
.01�F
100ꢀ
RD -
RX_LOS
VEER
RX_LOS
Vcc
R
EEPROM
1
R1
R1
R1
MOD_DEF 2
MOD_DEF 1
MOD_DEF 0
R1=4.7K to 10Kꢀ
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1702-Apr3007
Rev 0.1
6
SFP Bi-Directional Transceiver
Preliminary
SPL-53-DR-IR2
Ordering Information
Available Options:ꢀ
SPL-53-DR-IR2-CDA
SPL-53-DR-IR2-CNA
SPL-53-DR-IR2-TDA
SPL-53-DR-IR2-TNA
Part numbering Definition:
SPL - 53 - DR - IR2 - Temperature Diagnostic Revision
• SPL = LC connector
• 53 = Tx 1550nm/Rx 1310nm
• DR = Dual Rate 155M/622M
• IR2 = Reach 40 km
• Operating Temperature
C = Commercial temperature (-5 to 70ºC)
T = Industrial temperature (-40 to 85ºC)
• D = Digital Diagnostic (SFF-8472)
N = No Diagnostic
• Design Revision
A = RoHS compliant (lead free soldered)
Warnings:
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow
guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notes:
IMPORTANT NOTICE!
All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance
of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are
given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warran-
ties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of
Sale for further warranty information.
LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual
property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes
no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this docu-
ment are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers
using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from
such use or sale.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any
actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact
LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current.
© LuminentOIC, Inc. 2003
All rights reserved
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1702-Apr3007
Rev 0.1
7
相关型号:
SPL-53-DR-IR2-TDA
SFP Bi-Directional Transceiver PreliminaryWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SOURCE
SPL-53-DR-IR2-TNA
SFP Bi-Directional Transceiver PreliminaryWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SOURCE
SPL-53-FE-BD-CDA
SFP Bi-Directional TransceiverWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SOURCE
SPL-53-FE-BD-CNA
SFP Bi-Directional TransceiverWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SOURCE
SPL-53-FE-BD-TDA
SFP Bi-Directional TransceiverWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SOURCE
SPL-53-FE-BD-TDC
Transceiver, 1260nm Min, 1600nm Max, 100Mbps(Tx), 100Mbps(Rx), LC Connector, Panel MountWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SOURCE
SPL-53-FE-BD-TNA
SFP Bi-Directional TransceiverWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SOURCE
SPL-53-FE-BX-CDA
SFP Bi-Directional TransceiverWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SOURCE
SPL-53-FE-BX-CDC
Fiber Optic DeviceWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SOURCE
SPL-53-FE-BX-CNA
SFP Bi-Directional TransceiverWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SOURCE
SPL-53-FE-BX-CNC
Transceiver, 1480nm Min, 1580nm Max, 155Mbps(Tx), 155Mbps(Rx), LC Connector, Panel Mount, ROHS COMPLIANT PACKAGE-20Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SOURCE
SPL-53-FE-BX-TDA
SFP Bi-Directional TransceiverWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SOURCE
©2020 ICPDF网 联系我们和版权申明