SPS-53-FE-BX-TNA [SOURCE]

Fiber Optic Device,;
SPS-53-FE-BX-TNA
型号: SPS-53-FE-BX-TNA
厂家: SOURCE PHOTONICS, INC.    SOURCE PHOTONICS, INC.
描述:

Fiber Optic Device,

文件: 总7页 (文件大小:554K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
SFP Bi-directional Transceiver  
SPS-53-FE-BX  
Features  
• Compliant with OC3/STM-1, IEEE 802.3ah, 100BASE-BX10  
• Simplex SC Connector  
• Digital Diagnostic SFF-8472 Compliant  
• 14 dB Minimum Power Budget  
• 20 km Typical reach  
• Commercial and Industrial Temperature Available  
• Single 3.3V Supply  
• 1530 nm FP Laser  
• Bellcore GR-468 Compliant  
• Color Coded Yellow Bail Latch  
General Operating  
Parameter  
Symbol  
Vcc  
Min.  
3.135  
-
Typ.  
Max.  
3.465  
300  
-
Unit  
V
Supply Voltage  
3.3  
Total Current  
ICC  
-
-
-
-
-
-
mA  
mVp-p  
ºC  
Power Supply Noise Rejection  
Operating Temerature(case)(-CXX)  
Operating Temerature(case)(-TXX)  
Storage Temperature  
Data Rate  
100  
-5  
Topr  
Topr  
Tstg  
DR  
70  
-40  
-40  
10  
85  
ºC  
85  
ºC  
155  
Mbps  
Transmitter Specifications, Optical  
Parameter  
Symbol  
Pop  
Min  
Typical  
Max  
-8  
Unit  
dBm  
dB  
-14  
-
-11  
-45  
-
Optical power  
XT  
-40  
-45  
-
Optical crosstalk  
Poff  
-
dBm  
dB  
Average Launch power of off Tx  
Extinction Ratio  
ER  
6.6  
-
Eye Mask  
IEEE 802.3 and SONET/SDH Compliant  
Optical Rise time (20% to 80% values)  
Optical Fall time (20% to 80% values)  
Mean Wavelength  
tr  
tf  
-
-
2
2
ns  
ns  
-
-
λ
1480  
1530  
1580  
4.6  
-120  
12  
nm  
nm  
dB/Hz  
dB  
Maximum RMS width (σ)  
σ
-
-
-
-
-
-
Relative Intensity Noise  
RIN  
ORLT  
Optical Return Loss Tolerance  
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
LUMINENTOIC.COM  
LUMNDS428-Jul1305  
rev A.0  
1
SFP Bi-directional Transceiver  
SPS-53-FE-BX  
Transmitter Specifications , Electrical  
Parameter  
Symbol  
Rin  
Min  
80  
250  
2
Typical  
Max  
120  
Unit  
Ω
100  
Input Differential Impedence  
PECL Single Ended data input swing  
TxFault_Fault  
Vin, p-p  
Vfault  
Vnormal  
Vd  
-
-
-
-
-
1200  
mV  
V
Vcc  
TxFault_Normal  
Vee  
2
Vee + 0.5  
Vcc  
V
TxDisable_Disable  
V
TxDisable_Enable  
Ven  
Vee  
Vee + 0.8  
V
Receiver Specifications, Optical  
Parameter  
Symbol  
Min  
-
Typical  
Max  
Unit  
dBm  
dBm  
dBm  
nm  
a
Receiver Power Low  
Rsens,low  
-30  
-28.2  
Receiver Power High  
Damage Threshold for Receiver  
Wavelength  
Rsens,high  
-8  
-
-
-
-
-
-
-
Pin, damage  
4
-
λ
-
1260  
-45  
-
1360  
LOS Assert  
-
-28.2  
-
dBm  
dBm  
dB  
LOS De-assert  
-
LOS hysteresis  
-
0.5  
a) at 10-12 BER, PRBS 27-1  
Electrical Output  
Parameter  
Symbol  
Min  
Typical  
Max  
800  
2
Unit  
mV  
ns  
Vout,p-p  
185  
-
-
-
PECL Single ended data output swing  
Data output rise time  
tr  
tf  
-
-
Data output fall time  
2
ns  
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
LUMINENTOIC.COM  
LUMNDS428-Jul1305  
rev A.0  
2
SFP Bi-directional Transceiver  
SPS-53-FE-BX  
Timing and Electrical  
Parameter  
Symbol  
t_on  
Min  
Typical  
Max  
25  
Unit  
ms  
µs  
-
-
-
-
-
-
-
-
Tx Disable Negate time  
t_off  
10  
Tx Disable assert time  
Time to initialize, including reset of Tx fault  
Tx fault Assert time  
t_init  
300  
100  
ms  
µs  
t_fault  
Tx Disable to reset  
t_reset  
t_loss_on  
t_loss_off  
f_serial_clock  
Rx_LOSH  
10  
-
-
-
-
-
-
-
-
-
-
300  
100  
100  
-
µs  
µs  
µs  
KHz  
V
LOS Assert time  
LOS De-assert time  
-
-
2
Serial ID Clock Rate  
RX_LOS Voltage (high)  
RX_LOS Voltage (low)  
LOS output voltage-Fault  
LOS output voltage-Normal  
RX_LOSL  
-
0.8  
V
VLOS fault  
VLOS normal  
2
Vcc  
V
Vee  
Vee + 0.5  
V
MOD_DEF (0:2)-High  
MOD_DEF (0:2)-Low  
Vh  
VI  
2
-
-
V
V
Vcc  
Vee  
Vee + 0.5  
Diagnostics  
Parameter  
Range  
-40 to 85  
-5 to 70  
0 to Vcc  
0 to 120  
Accuracy  
Unit  
ºC  
Calibration Bit Value  
Formula  
±3  
±3  
.1  
Internal  
Internal  
Internal  
External  
1/256 C  
1/256 C  
100µV  
-
Tc(C) = Tad(16 bit signed twos complement)/256  
Tc(C) = Tad(16 bit signed twos complement)/256  
V(Volts) = Vad(16 bit unsigned integer)*0.1  
Temperature(-TDA)  
Temperature(-CDA)  
Voltage  
ºC  
V
Bias Current  
5
mA  
I(mA) = Islope * Iad(16 bit unsigned integer)+Ioffset  
Tx_PWR(µW) = Tx_PWRslope*Tx_PWRad(16 bit unsigned  
integer)+Tx_PWRoffset  
Tx Power  
Rx Power  
0 to 0.5  
±3dB  
±3dB  
mW  
mW  
External  
External  
-
-
-24 to -8 dBm  
Rx_PWR(µW) = A0+A1*x+A2*x^2+A3*x^3+A4*x^4  
Pinout Definitions  
Pin  
Function  
Notes  
TX GND  
V
T
1
2
ee  
TX_FAULT  
Open Collector  
3
4
TX_DISABLE  
MOD_DEF2  
MOD_DEF1  
MOD_DEF0  
NC  
Internally Pulled High  
Serial Data Input  
Serial Clock Input  
Internally Grounded  
Not Connected  
Open Collector  
RX Ground  
5
6
7
8
LOS  
9
V
V
V
R
R
R
ee  
ee  
ee  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
RX Ground  
RX Ground  
RXD-  
RX Data Negative  
RX Data Positive  
RX GND  
RXD+  
V
R
ee  
V
V
R
RX Power  
CC  
CC  
T
TX Power  
V
T
TX GND  
ee  
TXD+  
TXD-  
TX Data Positive  
TX Data Negative  
TX GND  
V
T
ee  
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
LUMINENTOIC.COM  
LUMNDS428-Jul1305  
rev A.0  
3
SFP Bi-directional Transceiver  
SPS-53-FE-BX  
EEPROM Serial ID  
Name of Field  
Discription of Field  
Address  
20  
Hex  
4C  
55  
4D  
49  
4E  
ASCII  
L
U
M
I
EEPROM Serial ID  
21  
22  
23  
24  
N
E
SFP Vendor name (ASCII)  
25  
45  
4E  
Vendor Name  
26  
N
T
27  
54  
4F  
28  
O
I
29  
49  
43  
30  
C
37  
38  
39  
00  
06  
B5  
Vendor OUI  
IEEE vendor OUI code for Luminent Inc.  
40  
41  
42  
43  
44  
45  
46  
49  
50  
51  
52  
53  
53  
50  
53  
35  
33  
46  
45  
42  
58  
54  
44  
41  
S
P
S
5
3
F
Part number in ASCII, e.g.  
SPS-53-FE-BX-TDA  
Vendor PN  
E
B
X
T
D
A
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
LUMINENTOIC.COM  
LUMNDS428-Jul1305  
rev A.0  
4
SFP Bi-directional Transceiver  
SPS-53-FE-BX  
SC Connector Mechanical  
Units in inches (mm)  
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
LUMINENTOIC.COM  
LUMNDS428-Jul1305  
rev A.0  
5
SFP Bi-directional Transceiver  
SPS-53-FE-BX  
Suggested Transceiver Interface  
1H  
Vcc  
1H  
10F  
0.1F  
VCCT  
.01F  
Protocol IC  
LuminentOIC  
SFP  
R1  
10K  
TX_DISABLE  
TX_DISABLE  
TX_FAULT  
TD +  
Laser Driver  
TX_FAULT  
.01F  
SerDes  
100  
TD -  
.01F  
VEET  
VCCR  
0.1F  
RD +  
10F  
Receiver Amplifier  
.01F  
.01F  
100  
RD -  
RX_LOS  
VEER  
RX_LOS  
Vcc  
R
EEPROM  
1
R1  
R1  
R1  
MOD_DEF 2  
MOD_DEF 1  
MOD_DEF 0  
R1=47K to 10K  
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
LUMINENTOIC.COM  
LUMNDS428-Jul1305  
rev A.0  
6
SFP Bi-directional Transceiver  
SPS-53-FE-BX  
Ordering Information  
Available Options:  
SPS-53-FE-BX-CNA  
SPS-53-FE-BX-TNA  
SPS-53-FE-BX-CDA  
SPS-53-FE-BX-TDA  
Part numbering Definition:  
SPS - 53 - FE - BX -  
X
X
A
• SPS = SC connector  
• Wavelength  
53 = Tx 1530nm/Rx 1310nm  
• Data Rate  
FE = Fast Ethernet (100Mbps)  
• Standard  
BX = 100BASE-BX  
• C= Commercial temperature (-5 to 70ºC)  
T= Industrial temperature (-40 to 85ºC)  
• D = Digital Diagnostic  
N = No Diagnostic  
• Revision  
Warnings:  
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow  
guidelines according to proper ESD procedures.  
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.  
Legal Notes:  
IMPORTANT NOTICE!  
All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance  
of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are  
given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warran-  
ties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of  
Sale for further warranty information.  
LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual  
property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes  
no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this docu-  
ment are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers  
using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from  
such use or sale.  
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any  
actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact  
LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current.  
© LuminentOIC, Inc. 2003  
All rights reserved  
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
LUMINENTOIC.COM  
LUMNDS428-Jul1305  
rev A.0  
7

相关型号:

UL1042

UL1042 - Uk砤d zr體nowa縪nego mieszacza iloczynowego

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

ZXFV201

QUAD VIDEO AMPLIFIER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX

ZXFV201N14

IC-SM-VIDEO AMP

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX

ZXFV201N14TA

QUAD VIDEO AMPLIFIER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX

ZXFV201N14TC

QUAD VIDEO AMPLIFIER

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

ZXFV302N16

IC-SM-4:1 MUX SWITCH

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

ZXFV4089

VIDEO AMPLIFIER WITH DC RESTORATION

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZETEX