XPD-MR-08-46CDA [SOURCE]
10 Gbps 80km DWDM Multirate XFP Transceiver; 10 Gbps的80公里多速率DWDM XFP收发器型号: | XPD-MR-08-46CDA |
厂家: | SOURCE PHOTONICS, INC. |
描述: | 10 Gbps 80km DWDM Multirate XFP Transceiver |
文件: | 总6页 (文件大小:649K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
10 Gbps 80km DWDM Multirate XFP Transceiver
Preliminary
XPD-MR-08-xxCDA
Features
• XFP MSA Rev 4.5 compliant
• Available in all 100GHz C-Band Wavelengths on the DWDM ITU
Grid
• 80km Reach
• Supports 9.95Gb/s, 10.31Gb/s, 10.52Gb/s, 10.7Gb/s, and 11.1Gb/s
• Cooled EML with isolator
• APD Receiver
• Power dissipation <3.5W
• -5 to 70 C temperature range
• Cold Start Up Wavelength Compliance
• Digital Diagnostics
• XFI High Speed Electrical Interface
• RoHS Compliant
• Class 1 Laser, 21CFR 1040.10/1040.11
• EN 60825-1/A1:2002 Compliant
• Bail Latch Color: WHITE
Absolute Maximum Rating
Parameter
Symbol
Vcc3
Vcc5
Vcc2
Tst
Min
-0.3
-0.3
-0.3
-40
Typical
Max
3.6
5.5
2
Unit
V
Maximum Supply Voltage (3.3V)
Maximum Supply Voltage (5.0V)
Maximum Supply Voltage (1.8V)
Storage Temperature
-
-
-
-
V
V
85
ºC
General Operations
Parameter
Symbol
Vcc2
Min
Typical
Max
1.89
3.47
5.25
500
1
Unit
V
Supply Voltage (1.8V)
Supply Voltage (3.3V)
Supply Voltage (5V)
1.71
1.8
Vcc3
3.14
3.3
V
Vcc5
4.75
5
-
-
-
-
-
-
-
-
-
-
V
Total Current on any pin
Inrush Current (1.8V)
Inrush Current (3.3V)
Inrush Current (5V)
ICC
-
-
-
-
-
-
-
-
-
-
mA
A
Iinrush
Iinrush
Iinrush
2
3
5
0.75
0.5
A
A
Module current ramp rate
Power on 1.8V rail
100
1.8
mA/µS
W
P
P
P
2rail
Power on 3.3V rail
2.5
W
3rail
5rail
Pt
Power on 5V rail
2.5
W
Module Total Power consumption
Power Consumption-P_Down mode
Power Supply Noise Rejection
Bit Rate
3.5
W
P
1.5
W
p_d
PSNR
BR
Compliant to Section 2.7.2 of XFP MSA
9.95
-
-
-
11.1
Gb/s
ºC
Operating Temperature (case)
Strorage Temperature
Top
Tst
-5
70
85
-40
ºC
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS420-NOV1106
Rev. 0.9
1
a) Peak to peak noise when measured with a 1 MHz low pass filter
b) Peak to peak noise when measured with 1MHz-10MHz low pass filter
10 Gbps 80km DWDM Multirate XFP Transceiver
Preliminary
XPD-MR-08-xxCDA
Transmitter Specifications (Optical)
Parameter
Symbol
PO
Min
Typical
Max
4
Unit
dBm
nm
Output Power
0
-
2
-
Average Launch Power Tx_Off
Extinction Ratio
Poff
-30
-
ER
9
-
dB
Eye Mask
ITU-T G.691, Telcordia GR-253-CORE, IEEE802.3 10GBASE-ZR Compliant
Side Mode Suppression Ratio
Center Wavelength
SMSR
30
-
-
dB
nm
GHz
nm
UI
ITU Grid
λ
Channel Spacing
-
-
-
-
-
-
-
100
-
∆f
∆λ20
Spectral Width
-
-
-
-
-
-
1
Jitter Generation (peak-to-peak)
Jitter Generation (RMS)
Dispersion Penalty at 1600 ps/nm
Relative Intensity Noise
Reflectance Tolerance
Jgen(pk-pk)
Jgen(RMS)
DP
0.1
0.01
2
UI
dB
RIN
-130
-27
dB/Hz
dB
ref T
Transmitter Specifications (Electrical)
Parameter
Symbol
Rin
Min
-
Typical
Max
-
Unit
Ω
Input Differential Impedence
Differential Data Input Swing
TxDisable_Disable
100
Vin,p-p
Vd
120
2
-
-
-
820
mV
V
Vcc3
TxDisable_Enable
Ven
GND
GND + 0.8
V
Receiver Specifications (Optical)
Parameter
Symbol
Rx sens995
Rx sens1070
Rx OL
Min
Typical
Max
-24
-23
-
Unit
dBm
dBm
dBm
nm
Sensitivity (9.95Gb/s)a
Sensitivity (10.7Gb/s)a
Overloada
-
-
-
-
-
-
-
-
-
-
-7
Wavelengthb
1528
-
1561
-27
-
λ
Optical Return Loss
LOS Assert
ORL
dB
-34
-
dBm
dBm
dB
-
-
-
LOS De-assert
-24
-
LOS Hysteresis
0.5
a) At 9dB ER, 1E-12 BER, 231-1 PRBS, back to back
b) Operational over 1200 - 1625nm range
Receiver Specificatioins (Elelctrical)
Parameter
Symbol
Min
Typical
Max
Unit
Ω
Reference Differential Output Impedence
Differential Data Output Swing
Output Rise Time, 20-80%
Output Fall Time, 20-80%
LOS Fault
Z
-
100
-
-
d
Vout,p-p
340
850
mV
ps
tr
24
24
-
-
-
-
ps
tf
VLOS_fault
host_Vcc3 - 0.5
GND
-
-
host_Vcc3
GND + 0.4
V
LOS Normal
VLOS_normal
V
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS420-NOV1106
Rev. 0.9
2
10 Gbps 80km DWDM Multirate XFP Transceiver
Preliminary
XPD-MR-08-xxCDA
Reference Clock
Parameter
Symbol
Min
80
Typical
Max
120
1600
60
Unit
Ω
Clock Differential Input Impedance
Differential Input Clock Amplitude (p-p)
Reference Clock Duty Cycle
Reference Clcok Rise/Fall Time (20%-80%)
Reference Clock Frequency
Zd
100
640
40
-
mV
%
-
Tr/Tf
200
-
-
1250
-
ps
f0
Baud/64
MHz
λ Wavelength Ordering
XPD-MR-08-xxCDA
See table below for “xx” values
λc Wavelength Guide
ITU Channel/Product Code Frequency (THz)
Wavelength (nm) ITU Channel/Product Code
Frequency (THz)
Wavelength (nm)
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
191.7
191.8
191.9
192.0
192.1
192.2
192.3
192.4
192.5
192.6
192.7
192.8
192.9
193.0
193.1
193.2
193.3
193.4
193.5
193.6
193.7
193.8
193.9
1563.863
1563.047
1562.233
1561.419
1560.606
1559.794
1558.983
1558.173
1557.363
1556.555
1555.747
1554.940
1554.134
1553.329
1552.524
1551.721
1550.918
1550.116
1549.315
1548.515
1547.715
1546.917
1546.119
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
194.0
194.1
194.2
194.3
194.4
194.5
194.6
194.7
194.8
194.9
195.0
195.1
195.2
195.3
195.4
195.5
195.6
195.7
195.8
195.9
196.0
196.1
1545.322
1544.526
1543.730
1542.936
1542.142
1541.349
1540.557
1539.766
1538.976
1538.186
1537.397
1536.609
1535.822
1535.036
1534.250
1533.465
1532.681
1531.898
1531.116
1530.334
1529.553
1528.773
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS420-NOV1106
Rev. 0.9
3
10 Gbps 80km DWDM Multirate XFP Transceiver
Preliminary
XPD-MR-08-xxCDA
Pin Out Definition
Pin
1
Logic
Symbol
GND
Name/Description
Module Ground
Note
1
2
VEE5
Optional -5.2V Power Supply (not used)
3
LVTTL-I
LVTTL-O
LVTTL-I
Mod_DeSel
Module De-select; When held low allows module to respond to 2-wire interface
Interrupt; Indicates presence of an important condition which can be read over the 2-wire
serial interface
4
Interrupt
2
1
5
TX_DIS
Vcc5
Transmitter Disable; Turns off transmitter laser output
+5V Power Supply
6
7
GND
Module Ground
8
Vcc3
+3.3V Power Supply
9
Vcc3
+3.3V Power Supply
10
11
12
13
14
15
16
17
18
19
20
LVTTL-I/O
LVTTL-I/O
LVTTL-O
LVTTL-O
LVTTL-O
SCL
2-Wire Serial Interface Clock
2-Wire Serial Interface Data Line
Indicates Module is not present. Grounded in the Module
Module Not Ready; Indicating Module Operational Fault
Receiver Loss Of Signal Indicator
Module Ground
2
2
2
2
2
1
1
SDA
Mod_Abs
Mod_NR
RX_LOS
GND
GND
Module Ground
CML-O
CML-O
RD-
Receiver Inverted Data Output
Receiver Non-Inverted Data Output
Module Ground
RD+
GND
1
Vcc2
+1.8V Power Supply
Power Down; When high, requires the module to limit power consumption to 1.5W or
below. 2-Wire serial interface must be functional in the low power mode.
21
LVTTL-I
P_Down/RST
Reset; The falling edge initiates a complete reset of the module including the 2-wire serial
interface, equivalent to a power cycle.
22
23
24
25
26
27
28
29
30
Vcc2
GND
+1.8V Power Supply
Module Ground
1
PECL-I
PECL-I
RefCLK+
RefCLK-
GND
Reference Clock Non-Inverted Input, AC coupled on the host board
Reference Clock Inverted Input, AC coupled on the host board
Module Ground
1
1
GND
Module Ground
CML-I
CML-I
TD-
Transmitter Inverted Data Input
Transmitter Non-Inverted Data Input
Module Ground
TD+
GND
1
Notes:
1. Module ground pins GND are isolated from the module case and chassis ground within the module.
2. Shall be pulled up with 4.7k-10kohms to a voltage between 3.15V and 3.45V on the host board.
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS420-NOV1106
Rev. 0.9
4
10 Gbps 80km DWDM Multirate XFP Transceiver
Preliminary
XPD-MR-08-xxCDA
Pinout Diagram
GND
15
16
17
18
19
GND
RD-
14
13
12
11
10
9
RX_LOS
MOD_NR
RD+
MOD_ABS
GND
SDA
SCL
20
21
VCC2
P_D OWN/RST
VCC3
VCC3
GND
22
23
VCC2
GND
8
T
ASIC
OWARD
TOWARD
BEZEL
7
24
REF CLK+
REF CLK-
VCC5
6
25
26
TX_DIS
5
GND
INTERR UPT
4
GND
TD-
27
28
29
30
M
OD_DESEL
3
VEE5
GND
2
TD+
1
GND
Host PCB XFP Pinout T op View
Mechanical Drawing
6.91
.272
16.15
.636
69.09
2.720
11.47
.451
8.95
.352
8.44
.332
3.80
.150
12.19
.480
6.02
.237
6.25
.246
77.98
3.070
18.29
.720
ISO VIEW
1. LUMINENOIC'S XFP TRANSCEIVERS ARE COMPLIANT WITH THE
DIMENSIONS DEFINED BY XFP MULTISOURCING AGREEMENT (MSA).
NOTES: UNLESS OTHERWISE SPECIFIED
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS420-NOV1106
Rev. 0.9
5
10 Gbps 80km DWDM Multirate XFP Transceiver
Preliminary
XPD-MR-08-xxCDA
Ordering Information
Part Numbering Definition:
X P D - M R -
Reach
- ITU Channel Temperature Diagnostic Revision
XPD = DWDM XFP
MR = Multi-Rate
08 = 80km
xx = 15 to 61
C = Commerical Temp
(-5 to 70C)
D = Digital Diagnostic
A = Design Revision
Warnings
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow
guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notice
IMPORTANT NOTICE!
All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance
of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are
given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warran-
ties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of
Sale for further warranty information.
LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual
property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes
no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this docu-
ment are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers
using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from
such use or sale.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any
actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact
LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current.
© LuminentOIC, Inc. 2003
All rights reserved
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS420-NOV1106
Rev. 0.9
6
相关型号:
XPD-MR-08-46CDFA
Transceiver, 11100Mbps(Tx), 11100Mbps(Rx), LC Connector, Surface Mount, ROHS COMPLIANT PACKAGE
SOURCE
©2020 ICPDF网 联系我们和版权申明