XPD-MR-D1224CDA [SOURCE]

10 Gbps 120km DWDM Multirate XFP Transceiver Preliminary; 10 Gbps的120公里多速率DWDM XFP收发器的初步
XPD-MR-D1224CDA
型号: XPD-MR-D1224CDA
厂家: SOURCE PHOTONICS, INC.    SOURCE PHOTONICS, INC.
描述:

10 Gbps 120km DWDM Multirate XFP Transceiver Preliminary
10 Gbps的120公里多速率DWDM XFP收发器的初步

文件: 总6页 (文件大小:843K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
10 Gbps 120km DWDM Multirate XFP Transceiver  
Preliminary  
XPD-MR-D12-xxCDA  
Features  
• XFP MSA Rev 4.5 compliant  
• Available in all 100GHz C-Band Wavelengths on the DWDM ITU  
Grid  
• 120km Reach on SMF-28 fiber utilizing Electronic Dispersion  
Compensation (EDC)  
• Supports 9.95Gb/s, 10.31Gb/s, 10.52Gb/s, 10.7Gb/s, and 11.1Gb/s  
• Cooled EML with isolator  
• APD Receiver  
• Power dissipation <3.5W  
• -5 to 70 C temperature range  
• Cold Start Up Wavelength Compliance  
• Digital Diagnostics  
• XFI High Speed Electrical Interface  
• RoHS Compliant  
• Class 1 Laser, 21CFR 1040.10/1040.11  
• EN 60825-1/A1:2002 Compliant  
• Bail Latch Color: WHITE  
Absolute Maximum Rating  
Parameter  
Symbol  
Vcc3  
Vcc5  
Vcc2  
Tst  
Min  
-0.3  
-0.3  
-0.3  
-40  
Typical  
Max  
3.6  
5.5  
2
Unit  
V
Maximum Supply Voltage (3.3V)  
Maximum Supply Voltage (5.0V)  
Maximum Supply Voltage (1.8V)  
Storage Temperature  
-
-
-
-
V
V
85  
ºC  
General Operations  
Parameter  
Symbol  
Vcc2  
Min  
Typical  
Max  
1.89  
3.47  
5.25  
500  
1
Unit  
V
Supply Voltage (1.8V)  
Supply Voltage (3.3V)  
Supply Voltage (5V)  
1.71  
1.8  
Vcc3  
3.14  
3.3  
V
Vcc5  
4.75  
5
-
-
-
-
-
-
-
-
-
-
V
Total Current on any pin  
Inrush Current (1.8V)  
Inrush Current (3.3V)  
Inrush Current (5V)  
ICC  
-
-
-
-
-
-
-
-
-
-
mA  
A
Iinrush  
Iinrush  
Iinrush  
2
3
5
0.75  
0.5  
A
A
Module current ramp rate  
Power on 1.8V rail  
100  
1.8  
mA/µS  
W
P
P
P
2rail  
Power on 3.3V rail  
2.5  
W
3rail  
5rail  
Pt  
Power on 5V rail  
2.5  
W
Module Total Power consumption  
Power Consumption-P_Down mode  
Power Supply Noise Rejection  
Bit Rate  
3.5  
W
P
1.5  
W
p_d  
PSNR  
BR  
Compliant to Section 2.7.2 of XFP MSA  
9.95  
-
-
-
11.1  
Gb/s  
ºC  
Operating Temperature (case)  
Strorage Temperature  
Top  
Tst  
-5  
70  
85  
-40  
ºC  
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
LUMINENTOIC.COM  
LUMNDS640-AUG072007  
Rev. 0.3  
1
a) Peak to peak noise when measured with a 1 MHz low pass filter  
b) Peak to peak noise when measured with 1MHz-10MHz low pass filter  
10 Gbps 120km DWDM Multirate XFP Transceiver  
Preliminary  
XPD-MR-D12-xxCDA  
Transmitter Specifications (Optical)  
Parameter  
Symbol  
PO  
Min  
-2  
Typical  
Max  
2
Unit  
dBm  
nm  
Output Power  
0
-
Average Launch Power Tx_Off  
Extinction Ratio  
Poff  
-
-30  
-
ER  
8.2  
-
dB  
Eye Mask  
ITU-T G.691, Telcordia GR-253-CORE, IEEE802.3 10GBASE-ZR Compliant  
Side Mode Suppression Ratio  
Center Wavelength  
SMSR  
30  
-
-
dB  
nm  
GHz  
nm  
UI  
ITU Grid  
λ
Channel Spacing  
-
-
-
-
-
-
-
100  
-
f  
∆λ20  
Spectral Width  
-
-
-
-
-
-
1
Jitter Generation (peak-to-peak)  
Jitter Generation (RMS)  
Dispersion Penalty at 2000 ps/nma  
Relative Intensity Noise  
Reflectance Tolerance  
a) Using an EDC enabled receiver  
Jgen(pk-pk)  
Jgen(RMS)  
DP  
0.1  
0.01  
2
UI  
dB  
RIN  
-130  
-27  
dB/Hz  
dB  
ref T  
Transmitter Specifications (Electrical)  
Parameter  
Symbol  
Rin  
Min  
-
Typical  
Max  
-
Unit  
Input Differential Impedence  
Differential Data Input Swing  
TxDisable_Disable  
100  
Vin,p-p  
Vd  
120  
2
-
-
-
820  
mV  
V
Vcc3  
TxDisable_Enable  
Ven  
GND  
GND + 0.8  
V
Receiver Specifications (Optical)  
Parameter  
Symbol  
Rx sens995  
Rx sens1070  
Rx OL  
Min  
Typical  
Max  
-24  
-23  
-
Unit  
dBm  
dBm  
dBm  
nm  
Sensitivity (9.95Gb/s)a  
Sensitivity (10.7Gb/s)a  
Overloada  
-
-
-
-
-
-
-
-
-
-
-7  
Wavelengthb  
1528  
-
1561  
-27  
-
λ
Optical Return Loss  
LOS Assert  
ORL  
dB  
-34  
-
dBm  
dBm  
dB  
-
-
-
LOS De-assert  
-24  
-
LOS Hysteresis  
0.5  
a) At 8.2dB ER, 1E-12 BER, 231-1 PRBS, back to back  
b) Operational over 1200 - 1625nm range  
Receiver Specificatioins (Elelctrical)  
Parameter  
Symbol  
Min  
Typical  
Max  
Unit  
Ω
Reference Differential Output Impedence  
Differential Data Output Swing  
Output Rise Time, 20-80%  
Output Fall Time, 20-80%  
LOS Fault  
Z
-
100  
-
-
d
Vout,p-p  
340  
850  
mV  
ps  
tr  
24  
24  
-
-
-
-
ps  
tf  
VLOS_fault  
VLOS_normal  
host_Vcc3 - 0.5  
GND  
-
-
host_Vcc3  
GND + 0.4  
V
LOS Normal  
V
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
LUMINENTOIC.COM  
LUMNDS640-AUG072007  
Rev. 0.3  
2
10 Gbps 120km DWDM Multirate XFP Transceiver  
Preliminary  
XPD-MR-D12-xxCDA  
Reference Clock  
Symbol  
Min  
80  
Typical  
Max  
120  
1600  
60  
Unit  
Clock Differential Input Impedance  
Differential Input Clock Amplitude (p-p)  
Reference Clock Duty Cycle  
Zd  
100  
640  
40  
-
mV  
%
-
Reference Clcok Rise/Fall Time (20%-80%)  
Reference Clock Frequency  
Tr/Tf  
200  
-
-
1250  
-
ps  
f0  
Baud/64  
MHz  
λ Wavelength Ordering  
XPD-MR-D12-xxCDA  
See table below for “xx” values  
λc Wavelength Guide  
ITU Channel/Product Code Frequency (THz)  
Wavelength (nm) ITU Channel/Product Code  
Frequency (THz)  
Wavelength (nm)  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
191.7  
191.8  
191.9  
192.0  
192.1  
192.2  
192.3  
192.4  
192.5  
192.6  
192.7  
192.8  
192.9  
193.0  
193.1  
193.2  
193.3  
193.4  
193.5  
193.6  
193.7  
193.8  
193.9  
1563.863  
1563.047  
1562.233  
1561.419  
1560.606  
1559.794  
1558.983  
1558.173  
1557.363  
1556.555  
1555.747  
1554.940  
1554.134  
1553.329  
1552.524  
1551.721  
1550.918  
1550.116  
1549.315  
1548.515  
1547.715  
1546.917  
1546.119  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
194.0  
194.1  
194.2  
194.3  
194.4  
194.5  
194.6  
194.7  
194.8  
194.9  
195.0  
195.1  
195.2  
195.3  
195.4  
195.5  
195.6  
195.7  
195.8  
195.9  
196.0  
196.1  
1545.322  
1544.526  
1543.730  
1542.936  
1542.142  
1541.349  
1540.557  
1539.766  
1538.976  
1538.186  
1537.397  
1536.609  
1535.822  
1535.036  
1534.250  
1533.465  
1532.681  
1531.898  
1531.116  
1530.334  
1529.553  
1528.773  
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
LUMINENTOIC.COM  
LUMNDS640-AUG072007  
Rev. 0.3  
3
10 Gbps 120km DWDM Multirate XFP Transceiver  
Preliminary  
XPD-MR-D12-xxCDA  
Pin Out Definition  
Pin  
1
Logic  
Symbol  
GND  
Name/Description  
Module Ground  
Note  
1
2
VEE5  
Optional -5.2V Power Supply (not used)  
3
LVTTL-I  
LVTTL-O  
LVTTL-I  
Mod_DeSel  
Module De-select; When held low allows module to respond to 2-wire interface  
Interrupt; Indicates presence of an important condition which can be read over the 2-wire  
serial interface  
4
Interrupt  
2
1
5
TX_DIS  
Vcc5  
Transmitter Disable; Turns off transmitter laser output  
+5V Power Supply  
6
7
GND  
Module Ground  
8
Vcc3  
+3.3V Power Supply  
9
Vcc3  
+3.3V Power Supply  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
LVTTL-I/O  
LVTTL-I/O  
LVTTL-O  
LVTTL-O  
LVTTL-O  
SCL  
2-Wire Serial Interface Clock  
2-Wire Serial Interface Data Line  
Indicates Module is not present. Grounded in the Module  
Module Not Ready; Indicating Module Operational Fault  
Receiver Loss Of Signal Indicator  
Module Ground  
2
2
2
2
2
1
1
SDA  
Mod_Abs  
Mod_NR  
RX_LOS  
GND  
GND  
Module Ground  
CML-O  
CML-O  
RD-  
Receiver Inverted Data Output  
Receiver Non-Inverted Data Output  
Module Ground  
RD+  
GND  
1
Vcc2  
+1.8V Power Supply  
Power Down; When high, requires the module to limit power consumption to 1.5W or  
below. 2-Wire serial interface must be functional in the low power mode.  
21  
LVTTL-I  
P_Down/RST  
Reset; The falling edge initiates a complete reset of the module including the 2-wire serial  
interface, equivalent to a power cycle.  
22  
23  
24  
25  
26  
27  
28  
29  
20  
Vcc2  
GND  
+1.8V Power Supply  
Module Ground  
1
PECL-I  
PECL-I  
RefCLK+  
RefCLK-  
GND  
Reference Clock Non-Inverted Input, AC coupled on the host board  
Reference Clock Inverted Input, AC coupled on the host board  
Module Ground  
1
1
GND  
Module Ground  
CML-I  
CML-I  
TD-  
Transmitter Inverted Data Input  
Transmitter Non-Inverted Data Input  
Module Ground  
TD+  
GND  
1
Notes:  
1. Module ground pins GND are isolated from the module case and chassis ground within the module.  
2. Shall be pulled up with 4.7k-10kohms to a voltage between 3.15V and 3.45V on the host board.  
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
LUMINENTOIC.COM  
LUMNDS640-AUG072007  
Rev. 0.3  
4
10 Gbps 120km DWDM Multirate XFP Transceiver  
Preliminary  
XPD-MR-D12-xxCDA  
Pinout Diagram  
GND  
15  
16  
17  
18  
19  
GND  
RD-  
14  
13  
12  
11  
10  
9
RX_LOS  
MOD_NR  
RD+  
MOD_ABS  
GND  
SDA  
SCL  
20  
21  
VCC2  
P_D OWN/RST  
VCC3  
VCC3  
GND  
22  
23  
VCC2  
GND  
8
T
ASIC  
OWARD  
TOWARD  
BEZEL  
7
24  
REF CLK+  
REF CLK-  
VCC5  
6
25  
26  
TX_DIS  
5
GND  
INTERR UPT  
4
GND  
TD-  
27  
28  
29  
30  
M
OD_DESEL  
3
VEE5  
GND  
2
TD+  
1
GND  
Host PCB XFP Pinout T op View  
Mechanical Drawing  
6.91  
.272  
16.15  
.636  
69.09  
2.720  
11.47  
.451  
8.95  
.352  
8.44  
.332  
3.80  
.150  
12.19  
.480  
6.02  
.237  
6.25  
.246  
77.98  
3.070  
18.29  
.720  
ISO VIEW  
1. LUMINENOIC'S XFP TRANSCEIVERS ARE COMPLIANT WITH THE  
DIMENSIONS DEFINED BY XFP MULTISOURCING AGREEMENT (MSA).  
NOTES: UNLESS OTHERWISE SPECIFIED  
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
LUMINENTOIC.COM  
LUMNDS640-AUG072007  
Rev. 0.3  
5
10 Gbps 120km DWDM Multirate XFP Transceiver  
Preliminary  
XPD-MR-D12-xxCDA  
Ordering Information  
Part Numbering Definition:  
X P D - M R -  
Reach  
ITU Channel Temperature Diagnostic Revision  
XPD = DWDM XFP  
MR = Multi-Rate  
D12 = 120km  
with EDC  
xx = 15 to 61  
C = Commerical Temp  
(-5 to 70C)  
D = Digital Diagnostic  
A = Design Revision  
Warnings  
This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow  
guidelines according to proper ESD procedures.  
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.  
Legal Notice  
IMPORTANT NOTICE!  
All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance  
of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are  
given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warran-  
ties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of  
Sale for further warranty information.  
LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual  
property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes  
no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this docu-  
ment are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers  
using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from  
such use or sale.  
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any  
actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact  
LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current.  
© LuminentOIC, Inc. 2003  
All rights reserved  
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
LUMINENTOIC.COM  
LUMNDS640-AUG072007  
Rev. 0.3  
6

相关型号:

XPD-MR-D1224DA

Transceiver, 10000Mbps(Tx), 10000Mbps(Rx), Panel Mount, ROHS COMPLIANT PACKAGE-20
SOURCE

XPD-MR-D1225CDA

10 Gbps 120km DWDM Multirate XFP Transceiver Preliminary
SOURCE

XPD-MR-D1226CDA

10 Gbps 120km DWDM Multirate XFP Transceiver Preliminary
SOURCE

XPD-MR-D1227CDA

10 Gbps 120km DWDM Multirate XFP Transceiver Preliminary
SOURCE

XPD-MR-D1228CDA

10 Gbps 120km DWDM Multirate XFP Transceiver Preliminary
SOURCE

XPD-MR-D1229CDA

10 Gbps 120km DWDM Multirate XFP Transceiver Preliminary
SOURCE

XPD-MR-D1230CDA

10 Gbps 120km DWDM Multirate XFP Transceiver Preliminary
SOURCE

XPD-MR-D1230DA

Transceiver, 10000Mbps(Tx), 10000Mbps(Rx), Panel Mount, ROHS COMPLIANT PACKAGE-20
SOURCE

XPD-MR-D1231CDA

10 Gbps 120km DWDM Multirate XFP Transceiver Preliminary
SOURCE

XPD-MR-D1232CDA

10 Gbps 120km DWDM Multirate XFP Transceiver Preliminary
SOURCE

XPD-MR-D1233CDA

10 Gbps 120km DWDM Multirate XFP Transceiver Preliminary
SOURCE

XPD-MR-D1234CDA

10 Gbps 120km DWDM Multirate XFP Transceiver Preliminary
SOURCE