GDT/C6M Series  
Gas Discharge Tube  
C6M Series  
Features  
Electronic stability  
Small volume, easy to placement machine operation  
Large flow capacity, impact resistant ability  
Static electricity capacity, good insulation  
Reaction speed is 50 ns - 150 ns  
Applications  
ADSL MODEMFAXTELEPHONE  
RS485RS232CAN level of protection  
CATV  
Power supply prevents thunder common-mode protection  
Marking Code  
C6M09R  
C6M09  
Logo  
Logo  
Marking Code  
Marking Code  
With Wire  
Without Wire  
Product Name  
C 6 M 0 9 R X  
Internal Code(Default)  
R: With Lead  
Default: No Lead  
Nom. DC spark-over  
voltage Vs  
09:90V  
15:150V  
47:470V  
150:1500V  
Electrical Characteristics  
K: 3KA  
L: 5KA  
M:10KA  
H: 20KA  
B5: 2R/5*5mm  
B8: 2R/8*6mm  
C6: 3R/6*8mm  
C7: 3R/7*11.5mm  
C8: 3R/8*10mm  
Page 1 of 3  
www.spsemi.cn  
REV.2017.04.06  
S P S E M I  
ꢀ ꢁ ꢂ ꢃ  
GDT/C6M Series  
Dimensions  
8± 0.2  
Φ6± 0.2  
Φ0.8± 0.1  
4.4± 0.3  
4.4± 0.3  
Dimensions in millimeters  
Electrical Characteristics  
Nom.  
Nom.  
Nom.  
Impulse  
Discharge  
Current  
(@8/20μs)  
(KA)  
DC  
Spark-over  
Voltage  
Impulse  
Spark-over  
Voltage  
(@1KV/μs)  
(V)  
Insulation  
Resistance  
Alternating Impulse  
Discharge Discharge  
Current Current  
(@50HZ) (@8/20μs)  
Part Number  
Capacitance  
(pF)  
(@100V/s)  
(V)  
Without  
Wire  
With  
Wire  
(@DC)  
(V)  
(GΩ)  
(A)  
10  
10  
10  
10  
10  
10  
10  
(KA)  
10  
10  
10  
10  
10  
10  
10  
25  
C6M07R C6M07  
C6M09R C6M09  
C6M15R C6M15  
C6M23R C6M23  
C6M35R C6M35  
C6M47R C6M47  
C6M60R C6M60  
75± 20±  
90± 20±  
600  
600  
650  
650  
700  
750  
950  
5×2  
5×2  
5×2  
5×2  
5×2  
5×2  
5×2  
>1  
>1  
>1  
>1  
>1  
>1  
>1  
<1  
<1  
<1  
<1  
<1  
<1  
<1  
50  
50  
150± 20±  
230± 20±  
350± 20±  
470± 20±  
600± 20±  
100  
100  
250  
250  
Packaging Speci Cations  
Packaging:100 pieces bulk  
Initial Characteristics  
Specification  
Test Item  
Test Method  
Add and measure the DC Voltage gradually  
Maxto get the discharge threshold voltage.  
The measuring current is 1mA/1 second max.1sec.(1mA)  
DC-Spark-Over Voltage  
Vs  
It depands on each spec.  
Measure the insulation resistance of two end of  
leadwire under the specified DC voltage.  
Insulation  
Resistance  
100MΩ min.  
0.8pF max.  
Electrostatic Capacitance under the test condition  
of 1KHz,DC 6V(max).  
Capacitance C(pF)  
Page 2 of 3  
www.spsemi.cn  
REV.2017.04.06  
S P S E M I  
ꢀ ꢁ ꢂ ꢃ  
GDT/C6M Series  
Surge Characteristics  
Specification  
Test Item  
Test Method  
In the glass tube ends in 8/20 us surge tester, applying the model that  
corresponds to the impact resistance current, time interval for the  
60 s of plus or minus the test 5 times. Test the dc voltage,  
DC spark-over voltage  
JSE: Vs/Vs30%  
Surge withstand capability  
insulation resistance, static capacitance and check the appearance.  
Apply 10KV voltage charged in 1500pF condenser and  
apply the current to the specimen,200 times at 10  
seconds of intervals.  
Within standard mentioned in  
Initial Characteristics.  
Surge life test  
Enviromental Characteristics  
Specification  
Test Item  
Test Method  
After -40 3℃  
(1000hrs) / room temp.,normal humidity(4 hrs)  
cycle, measure the properties.  
Within standard mentioned in  
Initial Characteristics.  
Cold resistance  
Heat resistance  
After 125 2℃  
(1000hrs) / room temp.,normal humidity(4 hrs)  
cycle, measure the properties.  
Within standard mentioned in  
Initial Characteristics.  
After 85 2℃  
RH85%(1000hrs) / room temp.,normal humidity(4  
hrs) cycle, measure the properties.  
Within standard mentioned in  
Initial Characteristics.  
Temperature resistance  
Temperature period  
Tensile strength  
25 times repetition of cycle -40 3℃  
(30 Min.),roon temp., (4 Min.), 125 2(30Min.),  
room temp., normal humidity(4hrs) .  
Within standard mentioned in  
Initial Characteristics.  
Apply 2.5kgs load approximately 30 seconds, then check  
for pull-out and breaking of the lead wire.  
Within standard mentioned in  
Initial Characteristics.  
Bend the lead wire, with jig which radius is 0.75~0.8mm, at the point  
of 2mm from the body, under 0.25 kgs load applied at the right angle  
the direction of theamis and get the bent lead wire back to its  
original poing after the procedure was repeated 2times.  
Within standard mentioned in  
Initial Characteristics.  
Bending strength  
Apply flux and immerse in molten solder, up to the point of  
). Wash  
Resistance to soldering  
attachment  
by solder dip)  
Lead wire is evenly covered by  
solder over 90%.  
3mm from the body,for 5 sec. (235  
5
the leadwire and check for soldering adhesion.  
Resistance to soldering  
heat  
by solder dip)  
Apply flux and immerse in molten solder, up to the point of 3mm  
from the body,for 5 sec. (2355). Wash the leadwire  
and check forsoldering adhesion.)  
Within standard mentioned in  
Initial Characteristics.  
Page 3 of 3  
www.spsemi.cn  
REV.2017.04.06  

相关型号:

C6M35R

Gas Discharge Tube C6M Series
SPSEMI

C6M47

Gas Discharge Tube C6M Series
SPSEMI

C6M47R

Gas Discharge Tube C6M Series
SPSEMI

C6M60

Gas Discharge Tube C6M Series
SPSEMI

C6M60R

Gas Discharge Tube C6M Series
SPSEMI

C6MBAU

Audio/RCA Connector, 6 Pole(s), Solder Terminal,
SWITCH

C6NF30V

N-channel 30V - 0.020ohm - 6A - TSSOP8 2.5V-drive STripFE TM II Power MOSFET
STMICROELECTR

C6P0112N-A

0.92 DIAMETER 1.0 AMP 28 VDC
ETC

C6P0112N-RA

0.92 DIAMETER 1.0 AMP 28 VDC
ETC

C6P0206N-A

0.92 DIAMETER 1.0 AMP 28 VDC
ETC

C6P0206N-RA

0.92 DIAMETER 1.0 AMP 28 VDC
ETC

C6P0304N-A

0.92 DIAMETER 1.0 AMP 28 VDC
ETC