K60-300 [SPSEMI]
Radial leaded Devices;型号: | K60-300 |
厂家: | StarHope |
描述: | Radial leaded Devices |
文件: | 总3页 (文件大小:1346K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PPTC/K60 Series
Features
Radial leaded Devices
Applications
Almost anywhere there is a low voltage
power supply, up to DC30V and a load
to be protested, including:
Automotive electronics
Medical products
Cured,flame retardant epoxy polymer
insulating material meets UL94V-0
requirements
Bulk packaging,or tape and reel
available on most models
Industrial controls
Product dimensions (mm)
Model
K60-005
K60-010
K60-017
K60-020
K60-025
Fig
1(2)
1(2)
1(2)
1(2)
11(2)
1(2)
2
A(max)
5.0
B(max)
8.5
C(max)
D(typ)
5.1
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
5.5
9.5
5.1
7.4
12.7
12.7
12.7
13.0
16.2
16.2
17.8
18.4
18.4
18.0
18.0
19.6
21.3
22.9
22.9
26.4
26.4
33.5
33.5
5.1
7.4
5.1
7.4
5.1
-
7.4
5.1
K60-030
K60-040
K60-050
K60-065
K60-075
K60-090
K60-110Y
K60-110F
K60-135
K60-160
K60-185
K60-200
K60-250
K60-300
K60-375
K60-500
7.8
5.1
2
7.8
5.1
2
9.7
5.1
2
10.4
11.7
13.0
13.0
14.5
16.3
17.8
17.8
21.3
21.3
28.5
28.5
5.1
2
5.1
1
5.1
3
5.1
1
5.1
1
5.1
1
5.1
1
5.1
1
10.2
10.2
10.2
10.2
1
1
1
Physical Characteristcs
Material:Leads
K60-005~030
K60-040~090
K60-300~500
Tin plated copper,22AWG0.60mm or Tin-plated nickel-copper alloy,24AWG0.50mm
Tin plated copper,22AWG,0.60mm
Tin plated copper,20AWG,0.80mm
Environmental Specifications
Test
conditions
Resistance change
±8% typical
Passive aging
+85℃,100hts
+85℃,85%R.H.,100hrs
+125℃,to-55℃,10times
MIL-STD-202,Method 215
MIL-STD-202,Method 201
Humidity aging
Thermal shock
Resistance to solvent
±8% typical
±12% typical
No change
No change
Vibration
Storage conditions:-40℃ to 85℃
01 | www.spsemi.cn
REV.2014.05.01
PPTC/K60 Series
Electrical characteristics(25℃
)
Part
Ihold
Itrip
Vmax
Imax
Pd max
Maximum Time To Trip
Resistance
number
Current
(A)
Time
(S)
5
5
5
5
5
5
5
5
5
5
5
8
8
8
8
Rmin
(Ω)
Rmax
(Ω )
20.00
7.50
5.21
2.84
1.95
1.38
0.88
0.79
0.50
0.42
0.33
0.27
0.27
0.21
0.16
0.14
0.14
0.10
0.08
0.06
0.06
R1max
(Ω)
(A)
0.05
0.10
0.17
0.20
0.25
0.30
0.40
0.50
0.65
0.75
0.90
1.10
1.10
1.35
1.60
1.85
2.00
2.50
3.00
3.75
5.00
(A)
0.10
0.20
0.34
0.40
0.50
0.60
0.80
1.00
1.30
1.50
1.80
2.20
2.20
2.70
3.20
3.70
4.00
5.00
6.00
7.50
10.00
(Vdc)
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
(A)
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
(w)
0.30
0.38
0.48
0.41
0.45
0.49
0.56
0.77
0.88
0.92
0.99
0.15
0.15
0.12
0.09
0.08
0.07
0.05
0.04
0.03
0.02
K60-005
K60-010
K60-017
K60-020
K60-025
K60-030
K60-040
K60-050
K60-065
K60-075
K60-090
K60-110Y
K60-110F
K60-135
K60-160
K60-185
K60-200
K60-250
K60-300
K60-375
K60-500
0.25
0.50
0.85
1.00
1.25
1.50
2.00
2.50
3.25
3.75
4.50
5.50
5.50
6.75
8.00
9.25
10.00
12.50
15.00
18.75
25.00
7.30
2.50
2.00
1.50
1.00
0.76
0.55
0.50
0.31
0.25
0.20
0.15
0.15
0.12
0.09
0.08
0.07
0.05
0.04
0.03
0.02
30.00
12.00
8.00
4.49
3.00
2.20
1.40
1.20
0.74
0.62
0.49
0.40
0.40
0.32
0.24
0.21
0.21
0.15
0.12
0.10
0.10
8
8
8
8
24
24
Hold Current:Maximum current device will not trip in 25℃ still air.
Trip current:Minimum current at which the device will always trip in 25℃ still air
Ihold
Itrip
Vmax
Imax
Maximum operating volatge device can withstand without damage at ratde current(imax).
Maximum fault current device can withstand without damage at rated voltage(Vmax).
Typical power dissipatde from device when in the tripped state in 25℃ still air.
Minimum/Maximum device resistance prior to tripping at 25℃.
Pd
Rmin/max
R1max
Maximum resistance of device at 25℃ measured one hour after trippde tripping.
*CAUTION Operation beyond the specified rating may result in damage and possible arcing.
Thermal Derating Chart-IH(A)
)
Maximum ambidnt operating temperatures(℃
Part number
-40
0.077
0.18
0.28
0.34
0.42
0.52
0.66
0.83
1.10
1.26
1.52
1.82
1.82
2.20
2.60
3.00
3.21
4.05
4.82
6.02
8.00
-20
0.069
0.15
0.24
0.29
0.36
0.44
0.57
0.74
0.95
1.11
1.30
1.60
1.60
1.91
2.30
2.63
2.72
3.58
4.16
5.19
6.80
0
25
0.050
0.10
0.17
0.20
0.25
0.30
0.40
0.50
0.65
0.75
0.90
1.10
1.10
1.35
1.60
1.85
2.00
2.50
3.00
3.75
5.00
40
0.044
0.08
0.14
0.16
0.20
0.24
0.32
0.41
0.53
0.61
0.73
0.90
0.90
1.09
1.30
1.50
1.62
2.02
2.43
3.02
4.05
50
0.040
0.07
0.12
0.14
0.18
0.22
0.29
0.36
0.47
0.54
0.65
0.79
0.79
0.96
1.13
1.33
1.44
1.80
2.16
2.68
3.60
60
0.036
0.06
0.10
0.13
0.16
0.18
0.24
0.30
0.40
0.45
0.55
0.65
0.65
0.80
1.00
1.12
1.26
1.55
1.85
2.30
3.15
70
0.032
0.05
0.09
0.10
0.12
0.14
0.20
0.25
0.33
0.39
0.47
0.55
0.55
0.68
0.80
0.92
1.08
1.30
1.50
1.95
2.70
80
0.025
0.03
0.06
0.07
0.09
0.10
0.14
0.18
0.24
0.28
0.33
0.40
0.40
0.50
0.60
0.67
0.80
0.90
1.09
1.39
2.00
K60-005
K60-010
K60-017
K60-020
K60-025
K60-030
K60-040
K60-050
K60-065
K60-075
K60-090
K60-110Y
K60-110F
K60-135
K60-160
K60-185
K60-200
K60-250
K60-300
K60-375
K60-500
0.061
0.13
0.20
0.25
0.31
0.38
0.50
0.63
0.82
0.95
1.15
1.35
1.35
1.65
1.95
2.30
2.38
3.02
3.62
4.50
5.95
REV.2014.05.01
02 | www.spsemi.cn
PPTC/K60 Series
Typical Time-To-Trip Curve At 25°C
Thermal Derating Curve
0.100A
0.170A
0.200A
0.250A
0.300A
0.400A
0.500A
0.650A
0.750A
0.900A
1.10A
Average Time Current Curves
1000
Derating Curves for K60 Series
180
160
140
120
100
80
100
10
1
1.35A
60
1.60A
1.85A
40
0.1
0.01
2.50A
3.00A
20
3.75A
0
-40
-20
0
20
40
60
80
0.1
1
10
100
CURRENT IN AMPERES
Temperature (°C)
Package Information
Bulk:
K60-005~110Y
K60-110F~300
1000pcs per bag
500pcs per bag
k60-375~500
200pcs per bag
REV.2014.05.01
03 | www.spsemi.cn
相关型号:
©2020 ICPDF网 联系我们和版权申明