300 W Triple Vout Series  
Industrial Grade AC/DC Power Supply With PFC  
85-264 Vrms  
12/24/36/48 V  
300 W  
400 W  
Up to 91 %  
Input Voltage  
Semi-Regulated Output  
Output Continuous Output Transient Full Load Efficiency  
Includes 5 V (10 W) and 12 V (50 W) “Always On” Standby Power Outputs  
300ꢀWꢀOpenꢀFrame  
Configurations  
300ꢀWꢀEncasedꢀorꢀOpenꢀFrame  
600ꢀWꢀEncasedꢀFlatꢀorꢀStacked  
900ꢀWꢀEncasedꢀFlatꢀorꢀStacked  
300ꢀWꢀEncased  
900ꢀWꢀEncasedꢀStacked  
600ꢀWꢀEncasedꢀFlat  
• High efficiency (91% for 48 VOUT Model at 300 W)  
• Universal input voltage range  
• Over–current, over–voltage, and over–temp protection  
• DC Power Good / AC Power Good signals  
• Remote enable input  
• Semi-regulated output for bus stability  
• Parallel operation supported  
• Fan status output / Fan enable input  
• Small size: 3" x 5" x 1.45" (open frame)  
• RoHS 6/6 compliant  
• Integral fan cooling with speed control  
• Active PFC; EN61000-3-2 compliant  
• Low leakage; EN60601-1 compliant  
• Low noise; EN55011 / EN55022 Class B compliant  
• 5 V (10 W) and 12 V (50 W) standby outputs  
Product # AQ0300IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005050 Rev. C  
08/21/15  
Page 1  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 300 W  
Grade: Industrial  
Technical Specification  
ACuQor 300W Triple Vout Series Electrical Characteristics  
All specifications typical with TA = 25 °C, unless otherwise specified. Specifications subject to change without notice.  
GENERAL SPECIFICATIONS  
MAIN OUTPUT SPECIFICATIONS  
Output power (continuous) 85-132/170-264 Vrms  
Fundamental ripple freq.  
Input  
Output  
500 kHz  
250 kHz  
39 dBA @ 1 m max.  
300 W (Note 1)  
400 W (Note 1)  
See Figures 10  
(5 s transient)  
85-132/170-264 Vrms  
132-170 Vrms  
Audible noise  
Fan speed varies with temp.  
Weight (EA \ EC)  
(SC \ RC)  
343 g (12.1 oz) \ 446 g (15.7 oz)  
846 g (29.8 oz) \ 879 g (31 oz)  
1224 g (43.2 oz) \ 1298 g (45.8 oz)  
Nominal DC output  
voltage (at 250W)  
(Semi-regulated)  
12 Vout (model 1T)  
24 Vout (model 2T)  
36 Vout (model 3T)  
48 Vout (model 4T)  
12.4 V  
25 V  
37.5 V  
50 V  
(UC \ TC)  
MTBF  
MIL-217  
Demonstrated  
343.6 kHours  
TBD kHours  
Efficiency  
(see figs. 1, 3, 5, 7)  
(see Note 1)  
12 Vout, 115 Vrms, 300 W  
48 Vout, 115 Vrms, 300 W  
12 Vout, 230 Vrms, 300 W  
48 Vout, 230 Vrms, 300 W  
89% typ.  
90% typ.  
90% typ.  
91% typ.  
ISOLATION SPECIFICATIONS  
Isolation voltage  
Input to output  
Input to ground  
Output to ground  
3000 Vrms  
1500 Vrms  
500 Vrms  
Hold-up time (to -20%)  
(see Note 1)  
12 Vout  
24 / 36 / 48 Vout  
16 ms @ 300 W  
20 ms @ 300 W  
Maximum load capacitance 12 Vout  
16,000 µF  
8,000 µF  
4,000 µF  
2,000 µF  
Insulation resistance  
Leakage currents  
Output to ground  
10 MΩ min.  
24 Vout  
36 Vout  
48 Vout  
See Note 2  
ENVIRONMENTAL CHARACTERISTICS  
Thermal performance  
Operating ambient (see Figure 2)  
Non-operating ambient  
Non-condensing  
-40 ºC to +70 ºC  
-40 ºC to +85 ºC  
Output ripple voltage  
Switching frequency (20 MHz BW)  
Twice line frequency (at 300W)  
0.5% p-p  
5.0% p-p  
Relative humidity  
Altitude  
5-95% RH  
Turn-on delay  
2 s max.  
Operating  
Non-operating  
5-500 Hz  
10,000 ft max.  
30,000 ft max.  
Transient response  
Iout steps from 50-75%  
At 0.2 A/µs  
Cyclic restart  
3% typ / 6% max. dev.  
100 ms recovery  
Random vibration  
Shock  
0.03 g2/Hz  
Overvoltage protection  
Short circuit protection  
Total regulation  
110-120%  
115% rated Iout  
±6.0%  
Half-sine, 10 ms, 3 axes  
20 g peak  
Cyclic operation  
EMC CHARACTERISTICS  
Conducted emissions  
Over line, load and temperature  
EN55011 and EN55022, FCC  
part15  
Level B  
12V_STANDBY cross-reg. ΔVout caused by 50 W step  
0.5%  
Line frequency harmonics EN61000-3-2  
Class A  
Clause 5b  
Level 3  
Level 3  
Level 3  
Level 3  
Level 3  
Level 3  
3 A/m  
ΔVout caused by 10 W step  
5V_STANDBY cross-reg.  
Thermal protection  
REMOTE_ENABLE  
0.1%  
Voltage fluctuations  
ESD air  
EN61000-3-3  
EN61000-4-2  
EN61000-4-2  
EN61000-4-3  
EN61000-4-4  
EN61000-4-5  
EN61000-4-6  
EN61000-4-8  
EN61000-4-11  
Automatic recovery  
+125 ºC (PCB Temp)  
Input Low Voltage  
Input High Voltage  
0.45 V (max)  
4.15 V (min)  
ESD contact  
Radiated immunity  
Fast transients  
12V_STANDBY OUTPUT SPECIFICATIONS  
Output power 85-264 Vrms  
Nominal DC output voltage Semi-regulated  
50 W  
12.4 V  
Line surge immunity  
Conducted immunity  
Power freq. mag. field  
Voltage dip immunity  
Total regulation  
Over line, load and temperature  
±6.0%  
400 mV  
Main output cross-reg.  
Δ12V_STANDBY caused by Δ350W  
on main output  
Switching frequency (20 MHz BW)  
Twice line frequency  
Perf Criteria A, A, B  
<5% UT 10 ms,  
70% UT 500 ms,  
40% UT 100 ms  
Output ripple  
10 mV  
0.45 Vrms  
Output current  
Continuous  
4.2 A  
5.0 A  
NOTES:  
Short circuit protection  
Maximum load capacitance  
Cyclic operation  
1. Main output power rating always includes 5 V and 12 V standby outputs.  
2. Leakage currents see page 5.  
2,000 uF  
5V_STANDBY OUTPUT SPECIFICATIONS  
Output power 85-264 Vrms  
Nominal DC output voltage Fully regulated  
10 W  
5.0 V  
Total regulation  
Over line, load and temperature  
±5.0%  
2.0 A  
Output current  
Continuous  
Short circuit protection  
Maximum load capacitance  
Cyclic operation  
2.5 A  
1,000 uF  
INPUT SPECIFICATIONS  
AC input voltage  
Universal range  
85-264 Vrms  
47-63 Hz  
Input frequency  
Input current  
(see Note 1)  
115 Vrms @ 300 W  
230 Vrms @ 300 W  
3 Arms  
1.5 Arms  
Power factor  
>0.98  
40 A max.  
6.3 A  
Input surge current  
Internal input fuses  
264 Vrms (cold start)  
Both AC lines  
Product # AQ0300IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005050 Rev. C  
08/21/15  
Page 2  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 300 W  
Grade: Industrial  
Technical Specification  
Efficiency, Derating, and Vout Droop Curves  
100  
14.0  
13.5  
13.0  
12.5  
12.0  
11.5  
11.0  
10.5  
10.0  
95  
90  
85  
80  
75  
70  
65  
115 Vrms  
230 Vrms  
0
4
8
12  
16  
20  
24  
28  
0
100  
200  
300  
400  
Output Load (A)  
Output Power (W)  
Figure 1: 12 VOUT efficiency curves.  
Figure 2: 12 VOUT droop characteristic.  
100  
95  
90  
85  
80  
75  
70  
65  
28  
27  
26  
25  
24  
23  
22  
21  
20  
115 Vrms  
230 Vrms  
0
2
4
6
8
10  
12  
14  
16  
0
100  
200  
300  
400  
Output Load (A)  
Output Power (W)  
Figure 3: 24 VOUT efficiency curves.  
Figure 4: 24 VOUT droop characteristic.  
100  
95  
90  
85  
80  
75  
70  
65  
42  
40  
38  
36  
34  
32  
30  
115 Vrms  
230 Vrms  
0
1
2
3
4
5
6
7
8
9
10  
11  
0
100  
200  
300  
400  
Output Load (A)  
Output Power (W)  
Figure 5: 36 VOUT efficiency curves.  
Figure 6: 36 VOUT droop characteristic.  
Product # AQ0300IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005050 Rev. C  
08/21/15  
Page 3  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 300 W  
Grade: Industrial  
Technical Specification  
Efficiency, Derating, and Vout Droop Curves  
100  
54  
52  
50  
48  
46  
44  
42  
95  
90  
85  
80  
75  
70  
65  
115 Vrms  
230 Vrms  
0
1
2
3
4
5
6
7
0
100  
200  
300  
400  
Output Load (A)  
Output Power (W)  
Figure 7: 48 VOUT efficiency curves.  
Figure 8: 48 VOUT droop characteristic.  
500  
400  
400  
300  
200  
100  
300  
200  
100  
Transient  
Fan Enabled  
Continuous  
Fan Disabled  
0
0
132  
170  
-40 -30 -20 -10  
0
10  
20  
30  
40  
50  
60  
70  
80  
264  
85  
AmbientTemperature (ºC)  
InputAC Voltage (VRMS  
)
Figure 9: Continuous power derating curve in natural convection  
Figure 10: Rated output power vs Input AC Voltage  
Product # AQ0300IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005050 Rev. C  
08/21/15  
Page 4  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 300 W  
Grade: Industrial  
Technical Specification  
Leakage Currents  
AC Leakage Current  
AC Line Connection  
from Input to Earth  
Normal Open Neutral  
Condition  
Fault  
240 V L-N, 1 phase  
400 µA  
800 µA  
ACuQor Typical at  
110% nominal input 208 V L-L, 120 V L-N, 1 of 3 phases  
200 µA  
200 µA  
400 µA  
400 µA  
voltage 60 Hz  
240 V L-N-L, 120 V L-N, split phase  
Standard Testing Certifications  
SAFETY AGENCY CERTIFICATIONS  
CAN/CSA-C22.2 No. 60950-1:2007  
UL 60950-1:2007  
EN 60950-1/A1:2010  
CE Marked  
Product # AQ0300IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005050 Rev. C  
08/21/15  
Page 5  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 300 W  
Grade: Industrial  
CONNECTOR DETAILS  
OUTPUT CONNECTOR PINOUT (top side)  
Pin 1 FAN_GOOD  
Open collector with internal 5V pullup. See Figure A.  
Pulsed low on fan failure, 100ms, 50% duty.  
Short to VOUT(-) to disable fan.  
Pin 2 AC_POWER_GOOD  
Pin 3 DC_POWER_GOOD  
Open collector with internal 5V pullup. See Figure B.  
Pulled low on AC power dropout.  
Open collector with internal 5V pullup. See Figure B.  
Pulled low during startup ramp and within 5 ºC of  
temperature shutdown threshold.  
Pin 4 5V_STANDBY  
Pin 5 VOUT(+)  
Pin 6 VOUT(+)  
Pin 7 VOUT(+)  
Pin 8 VOUT(+)  
Pin 9 Reserved  
Pin 10 Reserved  
Pin 11 REMOTE_ENABLE  
5 V @ 10 W available whenever AC power is applied.  
Positive Output Voltage.  
Figure A: Fan status output / Fan enable input interface circuitry.  
Positive Output Voltage.  
Positive Output Voltage.  
Positive Output Voltage.  
Reserved for future use.  
5V_STANDBY  
Reserved for future use.  
Logic input. See Figure C.  
Pull high to enable main output.  
N4148  
Pin 12 12V_STANDBY  
Pin 13 VOUT(–)  
Pin 14 VOUT(–)  
Pin 15 VOUT(–)  
Pin 16 VOUT(–)  
12 V @ 50 W available whenever AC power is applied.  
Negative Output Voltage.  
5 k  
Negative Output Voltage.  
10 Ohms  
AC_POWER_GOOD or  
DC_POWER_GOOD  
Negative Output Voltage.  
N3904  
From AC/DC  
Monitor  
Negative Output Voltage.  
0.1 µF  
Circuitry  
VOUT(-)  
Figure B: Power good interface circuitry.  
12 V OUTPUT CONNECTOR PINOUT (bottom side)  
Pin 1 VOUT(+)  
Pin 2 VOUT(+)  
Pin 3 VOUT(+)  
Positive Output Voltage.  
Positive Output Voltage.  
Positive Output Voltage.  
Positive Output Voltage.  
Negative Output Voltage.  
Negative Output Voltage.  
Negative Output Voltage.  
Negative Output Voltage  
5V_STANDBY  
5V_STANDBY  
VOUT(+)  
Pin 4  
Pin 5 VOUT(–)  
Pin 6 VOUT(–)  
Pin 7 VOUT(–)  
Pin 8 VOUT(–)  
10 Ohms  
5 k  
To Enable  
Circuitry  
REMOTE_ENABLE  
0.1 µF  
10k  
VOUT(-)  
Figure C: Remote enable interface circuitry.  
MATING CONNECTORS  
Connector  
Type  
Contact  
INDIVIDUAL INPUT CONNECTOR PINOUT  
OUTPUT (16 pins)  
12V_OUTPUT (8 pins)  
INPUT  
Molex 430251600  
Molex 436450800  
JST VHR-5N  
Molex 430300008*  
Molex 430300008*  
JST SVH-41T-P1.1  
Pin 1  
Pin 3  
Pin 5  
Ground  
AC Neutral  
AC Line  
* Each contact rated for a maximum of 5.5 A.  
Product # AQ0300IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005050 Rev. C  
08/21/15  
Page 6  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 300 W  
Grade: Industrial  
Technical Specification  
MECHANICAL DRAWINGS  
(1 Module Open Frame Version — E Package Type)  
INPUT  
CONNECTOR  
6 - 32 STANDOFF  
1/4" HEX BODY  
.123 .019  
[3.12 0.48]  
BOTTOMSIDE  
CLEARANCE  
INPUT  
3.00 [76.2]  
Front  
3/16" INTERNAL THREAD  
(4 PIECES)  
.70  
[17.8]  
1.50  
[38.1]  
1.444 .053  
[36.67 1.34]  
INPUT  
CONNECTOR  
CONNECTOR  
.68  
OUTPUT  
[17.4]  
1.06  
[26.8]  
5.00  
[127]  
4.60  
[116.8]  
Back  
2.90  
[73.7]  
INPUT  
Manufacturing Label  
PN#  
S/N  
DATE CODE  
1.03  
[26.1]  
.13  
[3.2]  
OUTPUT  
CONNECTOR  
3.03 [77]  
.20  
[5.1]  
.13  
[3.3]  
OUTPUT  
CONNECTOR  
2.60 [66]  
Top  
Right  
Bottom  
(1 Module Encased Version — E Package Type)  
Top  
Right  
Bottom  
Front  
6 - 32 SELF-CLINCHING INSERT  
MOUNTING SCREW SHALL NOT  
PROTUDE 3/8INTO THE CHASSIS  
(4 PIECES)  
Ø .19  
[4.75]  
PLASTIC RIVET OD.  
3.59 [91.3]  
1.63  
[41.3]  
.70  
[17.8]  
1.63  
[41.3]  
16 15 14 13 12 11 10  
9
1
8
7
6
5
4 3 2  
OUTPUT  
.11  
[2.9]  
1.31  
[33.1]  
4.13  
[104.8]  
4.91  
[124.7]  
5.25  
[133.4]  
Back  
3.03  
[76.8]  
Manufacturing Label  
PN#  
S/N  
DATE CODE  
1.05  
[26.6]  
.75  
[19.1]  
3.04 [77.1]  
.23 [5.9]  
1.75 [44.5]  
.38 [9.5]  
1.48  
[37.5]  
.17  
[4.3]  
3.04 [77.1]  
3.50 [88.9]  
NOTES (applies to all mechanicals)  
1) Recommended screw tightening torque of 6 in.lbs  
2)Undimensioned components are shown for visual reference only  
3)All dimensions in inches [mm]  
Tolerances:  
x.xx in ± 0.02  
x.xxx in ± 0.010  
Product # AQ0300IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005050 Rev. C  
08/21/15  
Page 7  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 300 W  
Grade: Industrial  
Technical Specification  
MECHANICAL DRAWINGS  
(2 Modules Flat Version - R Package Type)  
3.63 [92.1]  
.38 [9.5]  
Front  
1.05 [26.7]  
INPUT  
5
3
1
5
3
1
Ø.19 [4.75] PLASTIC RIVET OD.  
6.75 [171.5]  
5.00 [127]  
1.48  
[37.5]  
TOP  
1.75 [44.5]  
Right  
5.25  
[133.4]  
4.88 [123.8]  
3.03  
[76.8]  
6.84[173.8]  
.75 [19.1]  
1.63 [41.3]  
16 15 14 13 12 11 10  
9
1
16 15 14 13 12 11 10  
8 7 6 5 4 3 2  
9
1
8
7
6
5
4
3
2
OUTPUT  
OUTPUT  
1.31 [33.1]  
.71 [18]  
.23[5.9]  
Back  
4.56[115.7]  
6.29[159.6]  
Bottom  
3.14[79.8]  
.17[4.3]  
6 - 32 Self - Clinching Insert  
Mounting Screw shall not Protude  
3/8” into the chassis (6 pieces)  
4.91[124.7]  
Product # AQ0300IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005050 Rev. C  
08/21/15  
Page 8  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 300 W  
Grade: Industrial  
Technical Specification  
MECHANICAL DRAWINGS  
(2 Modules Stacked Version - S Package Type)  
3.25  
[82.6]  
2.65  
[67.2]  
1.05  
[26.7]  
INPUT  
INPUT  
.38  
[9.5]  
6-32 SELF-CLINCHING INSERT  
MOUNTING SCREW SHALL NOT  
PROTRUDE 3/8INTO THE CHASSIS  
(4 PIECES)  
4.91  
[124.7]  
4.85  
[123.2]  
5.25  
[133.4]  
3.03  
[76.8]  
1.75  
[44.5]  
1.59  
[40.5]  
3.04  
[77.1]  
.17  
.61  
[15.4]  
.20  
[5.1]  
3.50  
[88.9]  
[4.3]  
.23  
[5.9]  
6-32 SELF-CLINCHING INSERT  
MOUNTING SCREW SHALL NOT  
PROTRUDE .200INTO THE CHASSIS  
(4 PIECES)  
1.31 [33.1]  
.71  
[18]  
2.30  
[58.5]  
Product # AQ0300IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005050 Rev. C  
08/21/15  
Page 9  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 300 W  
Grade: Industrial  
Technical Specification  
MECHANICAL DRAWINGS  
(3 Modules Flat Version - T Package Type)  
6.88 [174.6]  
3.63 [92.1]  
.38 [9.5]  
1.05  
[26.7]  
5
3
1
5
3
1
5
3
1
Ø .19  
[4.8]  
PLASTIC RIVET OD.  
INPUT  
1.48  
[37.5]  
5.25  
[133.4]  
4.88  
[123.8]  
3.03  
[76.8]  
1.75 [44.5]  
.75  
[19.1]  
5.00 [127]  
8.25 [12.096]  
10.00 [254]  
10.09 [256.4]  
1.63  
[41.3]  
16 15 14 13 12 11 10  
9
1
16 15 14 13 12 11 10  
9
1
16 15 14 13 12 11 10  
9
1
8
7
6
5
4
3
2
8
7
6
5
4
3
2
8
7
6
5
4 3 2  
.71  
[18]  
OUTPUT  
OUTPUT  
OUTPUT  
1.31 [33.1]  
4.56 [115.7]  
6.39 [162.4]  
7.81 [198.2]  
9.54 [242.2]  
.23 [5.9]  
.17 [4.3]  
3.14 [79.8]  
6 - 32 SELF-CLINCHING INSERT  
MOUNTING SCREW SHALL NOT  
PROTUDE 3/8INTO THE CHASSIS  
(6 PIECES)  
4.91  
[124.7]  
Product # AQ0300IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005050 Rev. C  
08/21/15  
Page 10  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 300 W  
Grade: Industrial  
Technical Specification  
MECHANICAL DRAWINGS  
(3 Modules Stacked Version - U Package Type)  
3.50  
[88.9]  
1.75  
[44.5]  
3.03 [76.8]  
5.25 [133.4]  
6-32 SELF-CLINCHING INSERT  
MOUNTING SCREW SHALL NOT  
PROTRUDE .200INTO THE CHASSIS  
(4 PIECES)  
4.875  
[123.83]  
4.85 [123.2]  
.20 [5.1]  
INPUT  
1
1
3
3
3
5
5
5
16 15 14 13 12 11 10  
9
1
8
7
6
5
4
3
2
OUTPUT  
OUTPUT  
OUTPUT  
4.26  
[108.2]  
INPUT  
3.92  
[99.5]  
16 15 14 13 12 11 10  
9
1
3.21  
8
7
6
5
4
3
2
[81.5]  
2.66  
[67.5]INPUT  
2.31  
[58.8]  
1
16 15 14 13 12 11 10  
9
1
1.05  
[26.7]  
8
7
6
5
4
3
2
.61  
[15.4]  
.71  
[18]  
.38  
[9.5]  
1.31  
[33.1]  
4.91 [124.7]  
.17 [4.3]  
.23 [5.9]  
6-32 SELF-CLINCHING INSERT  
MOUNTING SCREW SHALL NOT  
PROTRUDE 3/8INTO THE CHASSIS  
(4 PIECES)  
3.04  
[77.1]  
Product # AQ0300IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005050 Rev. C  
08/21/15  
Page 11  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 300 W  
Grade: Industrial  
PARALLEL OPERATION - MULTIPLE UNITS  
Chassis configurations for Parallel Units  
Specifications of Parallel Units  
ACuQor units are available either open-frame or pre-mounted As a rule, units wired in parallel behave the same as single units.  
at the factory. Up to 3 units can be mounted into a chassis, in Any specification will remain unchanged that is expressed in units  
either side-by-side or stacked configurations. For a complete list of of voltage, time, frequency, or efficiency. Specifications expressed  
options, see the “Part Numbering System” table on the last page, in terms of power, current, or capacitance, should be scaled by the  
under “Package Type, along with the Mechanical Drawings pages. number of units wired in parallel.  
Only side-by-side configurations can be populated with 500W units,  
since each includes a thermal pad underneath.  
ACuQor units are individually calibrated at the factory, so that the  
output voltage vs. output current characteristic is always consistent  
(see Vout droop characteristic figures). As such, multiple units will  
Interconnection of Parallel Units  
ACuQor units mounted in 2 and 3 unit chassis are not connected share output current accurately. Full current is guaranteed from a  
together. This allows the physical routing and connectivity of the bank of multiple units wired in parallel.  
external wiring to be customized to each application. The following  
table summarizes the recommended wiring to operate multiple  
units in parallel:  
Output Connector Signal  
REMOTE_ENABLE  
FAN_GOOD  
Suggested Connection  
Behavior with Multiple Units  
Wire in parallel  
Inputs activated simultaneously  
Wired-OR outputs – can be pulled low by any unit during an abnormal condition.  
AC_POWER_GOOD  
DC_POWER_GOOD  
VOUT(+), VOUT(-)  
12V_STANDBY*  
5V_STANDBY  
Built-in droop characteristic ensures graceful current sharing.  
Do not wire in parallel Fully regulated characteristic does not support current sharing. If placed in  
parallel, only the output with the highest set-point will drive current.  
*Note: Triple output models only.  
Product # AQ0300IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005050 Rev. C  
08/21/15  
Page 12  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 300 W  
Grade: Industrial  
INSTALLATION INSTRUCTIONS  
General:ꢀꢀACuQorꢀAC/DCꢀpowerꢀsuppliesꢀareꢀintendedꢀforꢀuseꢀ  
asꢀ componentsꢀ inꢀ industrialꢀ equipment.ꢀ ꢀ ACuQorꢀ unitsꢀ mustꢀ beꢀ  
properlyinstalledwithinenduseequipmentbeforetheycanbeꢀ  
safelyappliedasdescribedinthisdocument.Thesuitabilityofꢀ  
theꢀACuQor/equipmentꢀcombinationꢀmustꢀbeꢀverifiedꢀthroughꢀendꢀ  
productꢀinvestigation.  
Output:RefertotheConnectorDetailssectionforoutputcon-  
nectorꢀ wiringꢀ andꢀ signalꢀ I/Oꢀ functionality.ꢀ ꢀ Referꢀ toꢀ nameplateꢀ  
labelꢀ forꢀ outputꢀ currentꢀ ratings.ꢀ ꢀ Mainꢀ DCꢀ outputꢀ (Vout+,ꢀ Vout-)ꢀ  
pinsshoulduse20AWG(0.5mm2)wiresize.Individualmainꢀ  
outputꢀpinsꢀshouldꢀnotꢀbeꢀloadedꢀtoꢀmoreꢀthanꢀ5.5ꢀA.ꢀꢀForꢀcurrentsꢀ  
greaterꢀthanꢀ5.5ꢀA,ꢀmultipleꢀmainꢀoutputꢀpins/wiresꢀmustꢀbeꢀusedꢀ  
inꢀparallel.ꢀꢀAllꢀsignalꢀI/OꢀpinsꢀareꢀreferencedꢀtoꢀVout-.ꢀ  
Mounting:ꢀꢀReferꢀtoꢀtheꢀMechanicalꢀDrawingsꢀsection.ꢀꢀACuQorꢀ  
unitsꢀareꢀprovidedꢀwithꢀthreadedꢀstainless-steelꢀstand-offsꢀorꢀinsertsꢀ  
forꢀmounting.ꢀꢀThisꢀmountingꢀhardwareꢀisꢀinternallyꢀconnectedꢀtoꢀ  
theꢀ inputꢀ connectorꢀ protective-earthꢀ terminalꢀ forꢀ functional-earthꢀ  
EMCꢀcontrol.ꢀꢀAnyꢀorientationꢀ(vertical,ꢀhorizontal,ꢀetc.)ꢀmayꢀbeꢀ  
used.ꢀꢀAdequateꢀairꢀspaceꢀshouldꢀbeꢀprovidedꢀoverꢀtheꢀfanꢀintakeꢀ  
(top)ꢀ andꢀ exhaustꢀ (sides)ꢀ toꢀ allowꢀ forꢀ exchangeꢀ ofꢀ coolingꢀ air.ꢀ  
ACuQorꢀisꢀdesignedꢀforꢀaꢀpollutionꢀdegreeꢀ2ꢀenvironment.ꢀꢀTheꢀ  
suitabilityꢀofꢀtheꢀenclosedꢀACuQorꢀmechanicalꢀassembliesꢀmustꢀbeꢀ  
verifiedꢀthroughꢀendꢀproductꢀinvestigation.  
EMC:ꢀꢀACuQorꢀproductsꢀhaveꢀbeenꢀtestedꢀtoꢀtheꢀEMCꢀspecifica-  
tionsꢀlistedꢀinꢀtheꢀElectricalꢀCharacteristicsꢀsection.ꢀꢀHowever,ꢀendꢀ  
useꢀequipmentꢀmustꢀbeꢀtestedꢀtoꢀverifyꢀEMCꢀcompliance.  
Hipot Testing:ꢀ ꢀ ACuQorꢀ productsꢀ areꢀ ratedꢀ forꢀ Hipotꢀ testingꢀ  
levelsof1500Vacinputtoprotective-earth,500ꢀ Vacꢀ outputꢀ toꢀ  
protective-earth,and3000Vacinputtooutput.Whenperform-  
ingꢀ theꢀ 3000ꢀ Vacꢀ inputꢀ toꢀ outputꢀ test,ꢀ theꢀ testꢀ voltageꢀ mustꢀ beꢀ  
balancedevenly1500Vacinputandoutputtoprotective-earth.ꢀ  
Twooppositelyphasedtestvoltagesourcesorasingletestvolt-  
ageꢀsourceꢀwithꢀexternalꢀbalancingꢀimpedancesꢀ(capacitors)ꢀmayꢀ  
beꢀusedꢀtoꢀpreventꢀoverstressingꢀinputꢀorꢀoutputꢀtoꢀprotective-earthꢀ  
insulationꢀperꢀIEC/ENCꢀ60950-1.  
Encased models:ꢀ ꢀ Aꢀ minimumꢀ ofꢀ 5ꢀ mmꢀ electricalꢀ clearanceꢀ  
shouldꢀbeꢀallowedꢀfromꢀtheꢀconnectorꢀendsꢀofꢀencasedꢀmodels.  
Input:RefertotheConnectorDetailssectionforinputconnec-  
torꢀwiring.ꢀꢀACuQorꢀproductsꢀrequireꢀaꢀsingleꢀphaseꢀACꢀpowerꢀ  
sourceꢀofꢀ100-240Vꢀ50/60Hzꢀnominal.ꢀꢀReferꢀtoꢀnameplateꢀlabelꢀ  
forꢀ inputꢀ currentꢀ ratings.ꢀ ꢀ Aꢀ protective-earthꢀ connectionꢀ isꢀ alsoꢀ  
required.ꢀ ꢀ Minimumꢀ wireꢀ sizeꢀ ofꢀ 18ꢀ AWGꢀ (0.8mm2)ꢀ isꢀ recom-  
mended.ꢀꢀBothꢀsidesꢀofꢀtheꢀACꢀlineꢀareꢀinternallyꢀfusedꢀ(seeꢀtableꢀ  
forꢀspecificꢀmodels).ꢀꢀTheseꢀfusesꢀareꢀnotꢀuserꢀreplaceable.  
MODEL  
AQ0300  
AQ0400  
AQ0500  
Input Fuses (in Both AC Lines)  
Littelfuseꢀ6.3Aꢀ250Vꢀ21606.3XEP  
Littelfuseꢀ6.3Aꢀ250Vꢀ21606.3XEP  
Littelfuseꢀ10.0Aꢀ250Vꢀ216010XEP  
Fuses Total  
2
2
2
Product # AQ0300IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005050 Rev. C  
08/21/15  
Page 13  
AC Input: 85-264 Vrms  
DC Output: 12/24/36/48 V Semi-reg.  
Power: 300 W  
Grade: Industrial  
Ordering Information  
PART NUMBERING SYSTEM  
The part numbering system for SynQor’s ACuQor AC/DC power supplies follows the format shown in the table below.  
Not all combinations make valid part numbers, please contact SynQor for availability.  
Thermal  
Design  
Family  
Output Power  
Grade  
Range  
Output Voltage Package Type  
Options  
0300: 300 W  
0400: 400 W  
0500: 500 W  
0600: 600 W  
(2 x 300 W)  
0800: 800 W  
(2 x 400 W)  
0900: 900 W  
(3 x 300 W)  
1000: 1000 W  
(2 x 500 W)  
1200: 1200 W  
(3 x 400 W)  
1500: 1500 W  
(3 x 500 W)  
12: 12 V  
1T: 12 V /  
5 & 12 V STBY  
AQ:  
ACuQor series  
of AC-DC  
semi-regulated  
output power  
supplies  
24: 24 V  
E: 1 unit (3"x5")  
2T: 24 V /  
R: 2 units; flat  
5 & 12 V STBY  
S: 2 units; stacked  
U: Universal  
A: Open frame  
C: Encased  
Industrial Grade:  
IND: Industrial  
I: (Industrial)  
(85-264 VRMS) 36: 36 V  
3T: 36 V /  
T: 3 units; flat  
U: 3 units; stacked  
5 & 12 V STBY  
48: 48 V  
4T: 48 V /  
5 & 12 V STBY  
Example: AQ0300IU2TECIND  
ACCESSORIES  
SynQor offers a series of assemblies that can be ordered according to the table below. Mechanical drawings for these  
accessories are available for download in pdf format from the SynQor website.  
Part Number  
Description  
Input mating cable with pre-stripped wire ends (36” long).  
Output mating cables with pre-stripped wire ends (18” long).  
Same as AQ-CBL -OUT1C with an additional 8-pins connector.  
Output mating cable with connectors on both ends (18" long).  
Same as the AQ-CBL-OUT2C with an additional 8-pins connector.  
Single module bottom-side Mylar insulator for open frame mounting  
Evaluation board for up to three paralleled modules.  
AQ-CBL-INPUT1C  
AQ-CBL-OUT1C  
AQ-CBL-OUT1CD  
AQ-CBL-OUT2C  
AQ-CBL-OUT2CD  
AQ-INSUL1M  
AQ-EVAL-PRL3  
APPLICATION NOTES  
A variety of application notes and technical white papers can be downloaded in pdf format from the SynQor website.  
Online Application Notes  
Online Library of Technical White Papers  
SynQor website.  
Contact SynQor for further information and to order:  
PATENTS  
SynQor holds numerous U.S. patents, one or more of which apply to most of its power converter  
products. Any that apply to the product(s) listed in this document are identified by markings on  
the product(s) or on internal components of the product(s) in accordance with U.S. patent laws.  
SynQor’s patents include the following:  
Phone:  
Toll Free:  
Fax:  
E-mail:  
Web:  
978-849-0600  
888-567-9596  
978-849-0602  
power@synqor.com  
www.synqor.com  
155 Swanson Road  
Boxborough, MA 01719  
USA  
5,999,417  
6,896,526  
7,269,034  
7,787,261  
6,222,742  
6,927,987  
7,272,021  
8,023,290  
6,545,890  
7,050,309  
7,272,023  
8,149,597  
6,594,159  
7,072,190  
7,558,083  
8,493,751  
6,731,520  
7,085,146  
7,564,702  
8,644,027  
6,894,468  
7,119,524  
7,765,687  
Address:  
WARRANTY  
SynQor offers a two (2) year limited warranty. Complete warranty  
information is listed on our website or is available upon request from SynQor.  
Product # AQ0300IUxT  
Phone 1-888-567-9596  
www.SynQor.com  
Doc.# 005-005050 Rev. C  
08/21/15  
Page 14  

相关型号:

AQ-CBL-OUT2CD

Semi-regulated output for bus stability
SYNQOR

AQ010001

MAT AQUA 0.6X0.9 GREY
ETC

AQ010002

MAT AQUA 1.5X0.9 GREY
ETC

AQ010004

MAT AQUA 1.2X1.8 GREY
ETC

AQ020001

MAT AQUA 0.6X0.9 BLUE
ETC

AQ020002

MAT AQUA 1.5X0.9 BLUE
ETC

AQ020004

MAT AQUA 1.8X1.2 BLUE
ETC

AQ0300IU12EAIND

AC-DC Regulated Power Supply Module, ROHS COMPLIANT
SYNQOR

AQ0300IU12ECIND

AC-DC Regulated Power Supply Module, ROHS COMPLIANT
SYNQOR

AQ0300IU12EQIND

AC-DC Regulated Power Supply Module, ROHS COMPLIANT
SYNQOR

AQ0300IU12RAIND

AC-DC Regulated Power Supply Module, ROHS COMPLIANT
SYNQOR

AQ0300IU12RCIND

AC-DC Regulated Power Supply Module, ROHS COMPLIANT
SYNQOR