AQ-CBL-OUT2C [SYNQOR]
Semi-regulated output for bus stability;![AQ-CBL-OUT2C](http://pdffile.icpdf.com/pdf2/p00330/img/icpdf/AQ-CBL-OUT1C_2030367_icpdf.jpg)
型号: | AQ-CBL-OUT2C |
厂家: | ![]() |
描述: | Semi-regulated output for bus stability |
文件: | 总14页 (文件大小:4791K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
Technical
Specification
300 W Triple Vout Series
Industrial Grade AC/DC Power Supply With PFC
85-264 Vrms
12/24/36/48 V
300 W
400 W
Up to 91 %
Input Voltage
Semi-Regulated Output
Output Continuous Output Transient Full Load Efficiency
Includes 5 V (10 W) and 12 V (50 W) “Always On” Standby Power Outputs
300ꢀWꢀOpenꢀFrame
Configurations
•ꢀ300ꢀWꢀEncasedꢀorꢀOpenꢀFrame
•ꢀ600ꢀWꢀEncasedꢀFlatꢀorꢀStacked
•ꢀ900ꢀWꢀEncasedꢀFlatꢀorꢀStacked
300ꢀWꢀEncased
900ꢀWꢀEncasedꢀStacked
600ꢀWꢀEncasedꢀFlat
• High efficiency (91% for 48 VOUT Model at 300 W)
• Universal input voltage range
• Over–current, over–voltage, and over–temp protection
• DC Power Good / AC Power Good signals
• Remote enable input
• Semi-regulated output for bus stability
• Parallel operation supported
• Fan status output / Fan enable input
• Small size: 3" x 5" x 1.45" (open frame)
• RoHS 6/6 compliant
• Integral fan cooling with speed control
• Active PFC; EN61000-3-2 compliant
• Low leakage; EN60601-1 compliant
• Low noise; EN55011 / EN55022 Class B compliant
• 5 V (10 W) and 12 V (50 W) standby outputs
Product # AQ0300IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005050 Rev. C
08/21/15
Page 1
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 300 W
Grade: Industrial
Technical Specification
ACuQor 300W Triple Vout Series Electrical Characteristics
All specifications typical with TA = 25 °C, unless otherwise specified. Specifications subject to change without notice.
GENERAL SPECIFICATIONS
MAIN OUTPUT SPECIFICATIONS
Output power (continuous) 85-132/170-264 Vrms
Fundamental ripple freq.
Input
Output
500 kHz
250 kHz
39 dBA @ 1 m max.
300 W (Note 1)
400 W (Note 1)
See Figures 10
(5 s transient)
85-132/170-264 Vrms
132-170 Vrms
Audible noise
Fan speed varies with temp.
Weight (EA \ EC)
(SC \ RC)
343 g (12.1 oz) \ 446 g (15.7 oz)
846 g (29.8 oz) \ 879 g (31 oz)
1224 g (43.2 oz) \ 1298 g (45.8 oz)
Nominal DC output
voltage (at 250W)
(Semi-regulated)
12 Vout (model 1T)
24 Vout (model 2T)
36 Vout (model 3T)
48 Vout (model 4T)
12.4 V
25 V
37.5 V
50 V
(UC \ TC)
MTBF
MIL-217
Demonstrated
343.6 kHours
TBD kHours
Efficiency
(see figs. 1, 3, 5, 7)
(see Note 1)
12 Vout, 115 Vrms, 300 W
48 Vout, 115 Vrms, 300 W
12 Vout, 230 Vrms, 300 W
48 Vout, 230 Vrms, 300 W
89% typ.
90% typ.
90% typ.
91% typ.
ISOLATION SPECIFICATIONS
Isolation voltage
Input to output
Input to ground
Output to ground
3000 Vrms
1500 Vrms
500 Vrms
Hold-up time (to -20%)
(see Note 1)
12 Vout
24 / 36 / 48 Vout
16 ms @ 300 W
20 ms @ 300 W
Maximum load capacitance 12 Vout
16,000 µF
8,000 µF
4,000 µF
2,000 µF
Insulation resistance
Leakage currents
Output to ground
10 MΩ min.
24 Vout
36 Vout
48 Vout
See Note 2
ENVIRONMENTAL CHARACTERISTICS
Thermal performance
Operating ambient (see Figure 2)
Non-operating ambient
Non-condensing
-40 ºC to +70 ºC
-40 ºC to +85 ºC
Output ripple voltage
Switching frequency (20 MHz BW)
Twice line frequency (at 300W)
0.5% p-p
5.0% p-p
Relative humidity
Altitude
5-95% RH
Turn-on delay
2 s max.
Operating
Non-operating
5-500 Hz
10,000 ft max.
30,000 ft max.
Transient response
Iout steps from 50-75%
At 0.2 A/µs
Cyclic restart
3% typ / 6% max. dev.
100 ms recovery
Random vibration
Shock
0.03 g2/Hz
Overvoltage protection
Short circuit protection
Total regulation
110-120%
115% rated Iout
±6.0%
Half-sine, 10 ms, 3 axes
20 g peak
Cyclic operation
EMC CHARACTERISTICS
Conducted emissions
Over line, load and temperature
EN55011 and EN55022, FCC
part15
Level B
12V_STANDBY cross-reg. ΔVout caused by 50 W step
0.5%
Line frequency harmonics EN61000-3-2
Class A
Clause 5b
Level 3
Level 3
Level 3
Level 3
Level 3
Level 3
3 A/m
ΔVout caused by 10 W step
5V_STANDBY cross-reg.
Thermal protection
REMOTE_ENABLE
0.1%
Voltage fluctuations
ESD air
EN61000-3-3
EN61000-4-2
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Automatic recovery
+125 ºC (PCB Temp)
Input Low Voltage
Input High Voltage
0.45 V (max)
4.15 V (min)
ESD contact
Radiated immunity
Fast transients
12V_STANDBY OUTPUT SPECIFICATIONS
Output power 85-264 Vrms
Nominal DC output voltage Semi-regulated
50 W
12.4 V
Line surge immunity
Conducted immunity
Power freq. mag. field
Voltage dip immunity
Total regulation
Over line, load and temperature
±6.0%
400 mV
Main output cross-reg.
Δ12V_STANDBY caused by Δ350W
on main output
Switching frequency (20 MHz BW)
Twice line frequency
Perf Criteria A, A, B
<5% UT 10 ms,
70% UT 500 ms,
40% UT 100 ms
Output ripple
10 mV
0.45 Vrms
Output current
Continuous
4.2 A
5.0 A
NOTES:
Short circuit protection
Maximum load capacitance
Cyclic operation
1. Main output power rating always includes 5 V and 12 V standby outputs.
2. Leakage currents see page 5.
2,000 uF
5V_STANDBY OUTPUT SPECIFICATIONS
Output power 85-264 Vrms
Nominal DC output voltage Fully regulated
10 W
5.0 V
Total regulation
Over line, load and temperature
±5.0%
2.0 A
Output current
Continuous
Short circuit protection
Maximum load capacitance
Cyclic operation
2.5 A
1,000 uF
INPUT SPECIFICATIONS
AC input voltage
Universal range
85-264 Vrms
47-63 Hz
Input frequency
Input current
(see Note 1)
115 Vrms @ 300 W
230 Vrms @ 300 W
3 Arms
1.5 Arms
Power factor
>0.98
40 A max.
6.3 A
Input surge current
Internal input fuses
264 Vrms (cold start)
Both AC lines
Product # AQ0300IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005050 Rev. C
08/21/15
Page 2
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 300 W
Grade: Industrial
Technical Specification
Efficiency, Derating, and Vout Droop Curves
100
14.0
13.5
13.0
12.5
12.0
11.5
11.0
10.5
10.0
95
90
85
80
75
70
65
115 Vrms
230 Vrms
0
4
8
12
16
20
24
28
0
100
200
300
400
Output Load (A)
Output Power (W)
Figure 1: 12 VOUT efficiency curves.
Figure 2: 12 VOUT droop characteristic.
100
95
90
85
80
75
70
65
28
27
26
25
24
23
22
21
20
115 Vrms
230 Vrms
0
2
4
6
8
10
12
14
16
0
100
200
300
400
Output Load (A)
Output Power (W)
Figure 3: 24 VOUT efficiency curves.
Figure 4: 24 VOUT droop characteristic.
100
95
90
85
80
75
70
65
42
40
38
36
34
32
30
115 Vrms
230 Vrms
0
1
2
3
4
5
6
7
8
9
10
11
0
100
200
300
400
Output Load (A)
Output Power (W)
Figure 5: 36 VOUT efficiency curves.
Figure 6: 36 VOUT droop characteristic.
Product # AQ0300IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005050 Rev. C
08/21/15
Page 3
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 300 W
Grade: Industrial
Technical Specification
Efficiency, Derating, and Vout Droop Curves
100
54
52
50
48
46
44
42
95
90
85
80
75
70
65
115 Vrms
230 Vrms
0
1
2
3
4
5
6
7
0
100
200
300
400
Output Load (A)
Output Power (W)
Figure 7: 48 VOUT efficiency curves.
Figure 8: 48 VOUT droop characteristic.
500
400
400
300
200
100
300
200
100
Transient
Fan Enabled
Continuous
Fan Disabled
0
0
132
170
-40 -30 -20 -10
0
10
20
30
40
50
60
70
80
264
85
AmbientTemperature (ºC)
InputAC Voltage (VRMS
)
Figure 9: Continuous power derating curve in natural convection
Figure 10: Rated output power vs Input AC Voltage
Product # AQ0300IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005050 Rev. C
08/21/15
Page 4
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 300 W
Grade: Industrial
Technical Specification
Leakage Currents
AC Leakage Current
AC Line Connection
from Input to Earth
Normal Open Neutral
Condition
Fault
240 V L-N, 1 phase
400 µA
800 µA
ACuQor Typical at
110% nominal input 208 V L-L, 120 V L-N, 1 of 3 phases
200 µA
200 µA
400 µA
400 µA
voltage 60 Hz
240 V L-N-L, 120 V L-N, split phase
Standard Testing Certifications
SAFETY AGENCY CERTIFICATIONS
CAN/CSA-C22.2 No. 60950-1:2007
UL 60950-1:2007
EN 60950-1/A1:2010
CE Marked
Product # AQ0300IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005050 Rev. C
08/21/15
Page 5
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 300 W
Grade: Industrial
CONNECTOR DETAILS
OUTPUT CONNECTOR PINOUT (top side)
Pin 1 FAN_GOOD
Open collector with internal 5V pullup. See Figure A.
Pulsed low on fan failure, 100ms, 50% duty.
Short to VOUT(-) to disable fan.
Pin 2 AC_POWER_GOOD
Pin 3 DC_POWER_GOOD
Open collector with internal 5V pullup. See Figure B.
Pulled low on AC power dropout.
Open collector with internal 5V pullup. See Figure B.
Pulled low during startup ramp and within 5 ºC of
temperature shutdown threshold.
Pin 4 5V_STANDBY
Pin 5 VOUT(+)
Pin 6 VOUT(+)
Pin 7 VOUT(+)
Pin 8 VOUT(+)
Pin 9 Reserved
Pin 10 Reserved
Pin 11 REMOTE_ENABLE
5 V @ 10 W available whenever AC power is applied.
Positive Output Voltage.
Figure A: Fan status output / Fan enable input interface circuitry.
Positive Output Voltage.
Positive Output Voltage.
Positive Output Voltage.
Reserved for future use.
5V_STANDBY
Reserved for future use.
Logic input. See Figure C.
Pull high to enable main output.
N4148
Pin 12 12V_STANDBY
Pin 13 VOUT(–)
Pin 14 VOUT(–)
Pin 15 VOUT(–)
Pin 16 VOUT(–)
12 V @ 50 W available whenever AC power is applied.
Negative Output Voltage.
5 k
Negative Output Voltage.
10 Ohms
AC_POWER_GOOD or
DC_POWER_GOOD
Negative Output Voltage.
N3904
From AC/DC
Monitor
Negative Output Voltage.
0.1 µF
Circuitry
VOUT(-)
Figure B: Power good interface circuitry.
12 V OUTPUT CONNECTOR PINOUT (bottom side)
Pin 1 VOUT(+)
Pin 2 VOUT(+)
Pin 3 VOUT(+)
Positive Output Voltage.
Positive Output Voltage.
Positive Output Voltage.
Positive Output Voltage.
Negative Output Voltage.
Negative Output Voltage.
Negative Output Voltage.
Negative Output Voltage
5V_STANDBY
5V_STANDBY
VOUT(+)
Pin 4
Pin 5 VOUT(–)
Pin 6 VOUT(–)
Pin 7 VOUT(–)
Pin 8 VOUT(–)
10 Ohms
5 k
To Enable
Circuitry
REMOTE_ENABLE
0.1 µF
10k
VOUT(-)
Figure C: Remote enable interface circuitry.
MATING CONNECTORS
Connector
Type
Contact
INDIVIDUAL INPUT CONNECTOR PINOUT
OUTPUT (16 pins)
12V_OUTPUT (8 pins)
INPUT
Molex 430251600
Molex 436450800
JST VHR-5N
Molex 430300008*
Molex 430300008*
JST SVH-41T-P1.1
Pin 1
Pin 3
Pin 5
Ground
AC Neutral
AC Line
* Each contact rated for a maximum of 5.5 A.
Product # AQ0300IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005050 Rev. C
08/21/15
Page 6
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 300 W
Grade: Industrial
Technical Specification
MECHANICAL DRAWINGS
(1 Module Open Frame Version — E Package Type)
INPUT
CONNECTOR
6 - 32 STANDOFF
1/4" HEX BODY
.123 .019
[3.12 0.48]
BOTTOMSIDE
CLEARANCE
INPUT
3.00 [76.2]
Front
3/16" INTERNAL THREAD
(4 PIECES)
.70
[17.8]
1.50
[38.1]
1.444 .053
[36.67 1.34]
INPUT
CONNECTOR
CONNECTOR
.68
OUTPUT
[17.4]
1.06
[26.8]
5.00
[127]
4.60
[116.8]
Back
2.90
[73.7]
INPUT
Manufacturing Label
PN#
S/N
DATE CODE
1.03
[26.1]
.13
[3.2]
OUTPUT
CONNECTOR
3.03 [77]
.20
[5.1]
.13
[3.3]
OUTPUT
CONNECTOR
2.60 [66]
Top
Right
Bottom
(1 Module Encased Version — E Package Type)
Top
Right
Bottom
Front
6 - 32 SELF-CLINCHING INSERT
MOUNTING SCREW SHALL NOT
PROTUDE 3/8”INTO THE CHASSIS
(4 PIECES)
Ø .19
[4.75]
PLASTIC RIVET OD.
3.59 [91.3]
1.63
[41.3]
.70
[17.8]
1.63
[41.3]
16 15 14 13 12 11 10
9
1
8
7
6
5
4 3 2
OUTPUT
.11
[2.9]
1.31
[33.1]
4.13
[104.8]
4.91
[124.7]
5.25
[133.4]
Back
3.03
[76.8]
Manufacturing Label
PN#
S/N
DATE CODE
1.05
[26.6]
.75
[19.1]
3.04 [77.1]
.23 [5.9]
1.75 [44.5]
.38 [9.5]
1.48
[37.5]
.17
[4.3]
3.04 [77.1]
3.50 [88.9]
NOTES (applies to all mechanicals)
1) Recommended screw tightening torque of 6 in.lbs
2)Undimensioned components are shown for visual reference only
3)All dimensions in inches [mm]
Tolerances:
x.xx in ± 0.02
x.xxx in ± 0.010
Product # AQ0300IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005050 Rev. C
08/21/15
Page 7
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 300 W
Grade: Industrial
Technical Specification
MECHANICAL DRAWINGS
(2 Modules Flat Version - R Package Type)
3.63 [92.1]
.38 [9.5]
Front
1.05 [26.7]
INPUT
5
3
1
5
3
1
Ø.19 [4.75] PLASTIC RIVET OD.
6.75 [171.5]
5.00 [127]
1.48
[37.5]
TOP
1.75 [44.5]
Right
5.25
[133.4]
4.88 [123.8]
3.03
[76.8]
6.84[173.8]
.75 [19.1]
1.63 [41.3]
16 15 14 13 12 11 10
9
1
16 15 14 13 12 11 10
8 7 6 5 4 3 2
9
1
8
7
6
5
4
3
2
OUTPUT
OUTPUT
1.31 [33.1]
.71 [18]
.23[5.9]
Back
4.56[115.7]
6.29[159.6]
Bottom
3.14[79.8]
.17[4.3]
6 - 32 Self - Clinching Insert
Mounting Screw shall not Protude
3/8” into the chassis (6 pieces)
4.91[124.7]
Product # AQ0300IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005050 Rev. C
08/21/15
Page 8
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 300 W
Grade: Industrial
Technical Specification
MECHANICAL DRAWINGS
(2 Modules Stacked Version - S Package Type)
3.25
[82.6]
2.65
[67.2]
1.05
[26.7]
INPUT
INPUT
.38
[9.5]
6-32 SELF-CLINCHING INSERT
MOUNTING SCREW SHALL NOT
PROTRUDE 3/8”INTO THE CHASSIS
(4 PIECES)
4.91
[124.7]
4.85
[123.2]
5.25
[133.4]
3.03
[76.8]
1.75
[44.5]
1.59
[40.5]
3.04
[77.1]
.17
.61
[15.4]
.20
[5.1]
3.50
[88.9]
[4.3]
.23
[5.9]
6-32 SELF-CLINCHING INSERT
MOUNTING SCREW SHALL NOT
PROTRUDE .200”INTO THE CHASSIS
(4 PIECES)
1.31 [33.1]
.71
[18]
2.30
[58.5]
Product # AQ0300IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005050 Rev. C
08/21/15
Page 9
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 300 W
Grade: Industrial
Technical Specification
MECHANICAL DRAWINGS
(3 Modules Flat Version - T Package Type)
6.88 [174.6]
3.63 [92.1]
.38 [9.5]
1.05
[26.7]
5
3
1
5
3
1
5
3
1
Ø .19
[4.8]
PLASTIC RIVET OD.
INPUT
1.48
[37.5]
5.25
[133.4]
4.88
[123.8]
3.03
[76.8]
1.75 [44.5]
.75
[19.1]
5.00 [127]
8.25 [12.096]
10.00 [254]
10.09 [256.4]
1.63
[41.3]
16 15 14 13 12 11 10
9
1
16 15 14 13 12 11 10
9
1
16 15 14 13 12 11 10
9
1
8
7
6
5
4
3
2
8
7
6
5
4
3
2
8
7
6
5
4 3 2
.71
[18]
OUTPUT
OUTPUT
OUTPUT
1.31 [33.1]
4.56 [115.7]
6.39 [162.4]
7.81 [198.2]
9.54 [242.2]
.23 [5.9]
.17 [4.3]
3.14 [79.8]
6 - 32 SELF-CLINCHING INSERT
MOUNTING SCREW SHALL NOT
PROTUDE 3/8”INTO THE CHASSIS
(6 PIECES)
4.91
[124.7]
Product # AQ0300IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005050 Rev. C
08/21/15
Page 10
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 300 W
Grade: Industrial
Technical Specification
MECHANICAL DRAWINGS
(3 Modules Stacked Version - U Package Type)
3.50
[88.9]
1.75
[44.5]
3.03 [76.8]
5.25 [133.4]
6-32 SELF-CLINCHING INSERT
MOUNTING SCREW SHALL NOT
PROTRUDE .200”INTO THE CHASSIS
(4 PIECES)
4.875
[123.83]
4.85 [123.2]
.20 [5.1]
INPUT
1
1
3
3
3
5
5
5
16 15 14 13 12 11 10
9
1
8
7
6
5
4
3
2
OUTPUT
OUTPUT
OUTPUT
4.26
[108.2]
INPUT
3.92
[99.5]
16 15 14 13 12 11 10
9
1
3.21
8
7
6
5
4
3
2
[81.5]
2.66
[67.5]INPUT
2.31
[58.8]
1
16 15 14 13 12 11 10
9
1
1.05
[26.7]
8
7
6
5
4
3
2
.61
[15.4]
.71
[18]
.38
[9.5]
1.31
[33.1]
4.91 [124.7]
.17 [4.3]
.23 [5.9]
6-32 SELF-CLINCHING INSERT
MOUNTING SCREW SHALL NOT
PROTRUDE 3/8”INTO THE CHASSIS
(4 PIECES)
3.04
[77.1]
Product # AQ0300IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005050 Rev. C
08/21/15
Page 11
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 300 W
Grade: Industrial
PARALLEL OPERATION - MULTIPLE UNITS
Chassis configurations for Parallel Units
Specifications of Parallel Units
ACuQor units are available either open-frame or pre-mounted As a rule, units wired in parallel behave the same as single units.
at the factory. Up to 3 units can be mounted into a chassis, in Any specification will remain unchanged that is expressed in units
either side-by-side or stacked configurations. For a complete list of of voltage, time, frequency, or efficiency. Specifications expressed
options, see the “Part Numbering System” table on the last page, in terms of power, current, or capacitance, should be scaled by the
under “Package Type”, along with the Mechanical Drawings pages. number of units wired in parallel.
Only side-by-side configurations can be populated with 500W units,
since each includes a thermal pad underneath.
ACuQor units are individually calibrated at the factory, so that the
output voltage vs. output current characteristic is always consistent
(see Vout droop characteristic figures). As such, multiple units will
Interconnection of Parallel Units
ACuQor units mounted in 2 and 3 unit chassis are not connected share output current accurately. Full current is guaranteed from a
together. This allows the physical routing and connectivity of the bank of multiple units wired in parallel.
external wiring to be customized to each application. The following
table summarizes the recommended wiring to operate multiple
units in parallel:
Output Connector Signal
REMOTE_ENABLE
FAN_GOOD
Suggested Connection
Behavior with Multiple Units
Wire in parallel
Inputs activated simultaneously
“
“
“
“
“
Wired-OR outputs – can be pulled low by any unit during an abnormal condition.
AC_POWER_GOOD
DC_POWER_GOOD
VOUT(+), VOUT(-)
12V_STANDBY*
5V_STANDBY
“
“
Built-in droop characteristic ensures graceful current sharing.
“
Do not wire in parallel Fully regulated characteristic does not support current sharing. If placed in
parallel, only the output with the highest set-point will drive current.
*Note: Triple output models only.
Product # AQ0300IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005050 Rev. C
08/21/15
Page 12
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 300 W
Grade: Industrial
INSTALLATION INSTRUCTIONS
General:ꢀꢀACuQorꢀAC/DCꢀpowerꢀsuppliesꢀareꢀintendedꢀforꢀuseꢀ
asꢀ componentsꢀ inꢀ industrialꢀ equipment.ꢀ ꢀ ACuQorꢀ unitsꢀ mustꢀ beꢀ
properlyꢀinstalledꢀwithinꢀendꢀuseꢀequipmentꢀbeforeꢀtheyꢀcanꢀbeꢀ
safelyꢀappliedꢀasꢀdescribedꢀinꢀthisꢀdocument.ꢀꢀTheꢀsuitabilityꢀofꢀ
theꢀACuQor/equipmentꢀcombinationꢀmustꢀbeꢀverifiedꢀthroughꢀendꢀ
productꢀinvestigation.
Output:ꢀꢀReferꢀtoꢀtheꢀConnectorꢀDetailsꢀsectionꢀforꢀoutputꢀcon-
nectorꢀ wiringꢀ andꢀ signalꢀ I/Oꢀ functionality.ꢀ ꢀ Referꢀ toꢀ nameplateꢀ
labelꢀ forꢀ outputꢀ currentꢀ ratings.ꢀ ꢀ Mainꢀ DCꢀ outputꢀ (Vout+,ꢀ Vout-)ꢀ
pinsꢀshouldꢀuseꢀ20ꢀAWGꢀ(0.5mm2)ꢀwireꢀsize.ꢀꢀIndividualꢀmainꢀ
outputꢀpinsꢀshouldꢀnotꢀbeꢀloadedꢀtoꢀmoreꢀthanꢀ5.5ꢀA.ꢀꢀForꢀcurrentsꢀ
greaterꢀthanꢀ5.5ꢀA,ꢀmultipleꢀmainꢀoutputꢀpins/wiresꢀmustꢀbeꢀusedꢀ
inꢀparallel.ꢀꢀAllꢀsignalꢀI/OꢀpinsꢀareꢀreferencedꢀtoꢀVout-.ꢀ
Mounting:ꢀꢀReferꢀtoꢀtheꢀMechanicalꢀDrawingsꢀsection.ꢀꢀACuQorꢀ
unitsꢀareꢀprovidedꢀwithꢀthreadedꢀstainless-steelꢀstand-offsꢀorꢀinsertsꢀ
forꢀmounting.ꢀꢀThisꢀmountingꢀhardwareꢀisꢀinternallyꢀconnectedꢀtoꢀ
theꢀ inputꢀ connectorꢀ protective-earthꢀ terminalꢀ forꢀ functional-earthꢀ
EMCꢀcontrol.ꢀꢀAnyꢀorientationꢀ(vertical,ꢀhorizontal,ꢀetc.)ꢀmayꢀbeꢀ
used.ꢀꢀAdequateꢀairꢀspaceꢀshouldꢀbeꢀprovidedꢀoverꢀtheꢀfanꢀintakeꢀ
(top)ꢀ andꢀ exhaustꢀ (sides)ꢀ toꢀ allowꢀ forꢀ exchangeꢀ ofꢀ coolingꢀ air.ꢀ
ACuQorꢀisꢀdesignedꢀforꢀaꢀpollutionꢀdegreeꢀ2ꢀenvironment.ꢀꢀTheꢀ
suitabilityꢀofꢀtheꢀenclosedꢀACuQorꢀmechanicalꢀassembliesꢀmustꢀbeꢀ
verifiedꢀthroughꢀendꢀproductꢀinvestigation.
EMC:ꢀꢀACuQorꢀproductsꢀhaveꢀbeenꢀtestedꢀtoꢀtheꢀEMCꢀspecifica-
tionsꢀlistedꢀinꢀtheꢀElectricalꢀCharacteristicsꢀsection.ꢀꢀHowever,ꢀendꢀ
useꢀequipmentꢀmustꢀbeꢀtestedꢀtoꢀverifyꢀEMCꢀcompliance.
Hipot Testing:ꢀ ꢀ ACuQorꢀ productsꢀ areꢀ ratedꢀ forꢀ Hipotꢀ testingꢀ
levelsꢀofꢀ1500ꢀVacꢀinputꢀtoꢀprotective-earth,ꢀ500ꢀ Vacꢀ outputꢀ toꢀ
protective-earth,ꢀandꢀ3000ꢀVacꢀinputꢀtoꢀoutput.ꢀꢀWhenꢀperform-
ingꢀ theꢀ 3000ꢀ Vacꢀ inputꢀ toꢀ outputꢀ test,ꢀ theꢀ testꢀ voltageꢀ mustꢀ beꢀ
balancedꢀevenlyꢀ1500ꢀVacꢀinputꢀandꢀoutputꢀtoꢀprotective-earth.ꢀ
Twoꢀoppositelyꢀphasedꢀtestꢀvoltageꢀsourcesꢀorꢀaꢀsingleꢀtestꢀvolt-
ageꢀsourceꢀwithꢀexternalꢀbalancingꢀimpedancesꢀ(capacitors)ꢀmayꢀ
beꢀusedꢀtoꢀpreventꢀoverstressingꢀinputꢀorꢀoutputꢀtoꢀprotective-earthꢀ
insulationꢀperꢀIEC/ENCꢀ60950-1.
Encased models:ꢀ ꢀ Aꢀ minimumꢀ ofꢀ 5ꢀ mmꢀ electricalꢀ clearanceꢀ
shouldꢀbeꢀallowedꢀfromꢀtheꢀconnectorꢀendsꢀofꢀencasedꢀmodels.
Input:ꢀꢀReferꢀtoꢀtheꢀConnectorꢀDetailsꢀsectionꢀforꢀinputꢀconnec-
torꢀwiring.ꢀꢀACuQorꢀproductsꢀrequireꢀaꢀsingleꢀphaseꢀACꢀpowerꢀ
sourceꢀofꢀ100-240Vꢀ50/60Hzꢀnominal.ꢀꢀReferꢀtoꢀnameplateꢀlabelꢀ
forꢀ inputꢀ currentꢀ ratings.ꢀ ꢀ Aꢀ protective-earthꢀ connectionꢀ isꢀ alsoꢀ
required.ꢀ ꢀ Minimumꢀ wireꢀ sizeꢀ ofꢀ 18ꢀ AWGꢀ (0.8mm2)ꢀ isꢀ recom-
mended.ꢀꢀBothꢀsidesꢀofꢀtheꢀACꢀlineꢀareꢀinternallyꢀfusedꢀ(seeꢀtableꢀ
forꢀspecificꢀmodels).ꢀꢀTheseꢀfusesꢀareꢀnotꢀuserꢀreplaceable.
MODEL
AQ0300
AQ0400
AQ0500
Input Fuses (in Both AC Lines)
Littelfuseꢀ6.3Aꢀ250Vꢀ21606.3XEP
Littelfuseꢀ6.3Aꢀ250Vꢀ21606.3XEP
Littelfuseꢀ10.0Aꢀ250Vꢀ216010XEP
Fuses Total
2
2
2
Product # AQ0300IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005050 Rev. C
08/21/15
Page 13
AC Input: 85-264 Vrms
DC Output: 12/24/36/48 V Semi-reg.
Power: 300 W
Grade: Industrial
Ordering Information
PART NUMBERING SYSTEM
The part numbering system for SynQor’s ACuQor AC/DC power supplies follows the format shown in the table below.
Not all combinations make valid part numbers, please contact SynQor for availability.
Thermal
Design
Family
Output Power
Grade
Range
Output Voltage Package Type
Options
0300: 300 W
0400: 400 W
0500: 500 W
0600: 600 W
(2 x 300 W)
0800: 800 W
(2 x 400 W)
0900: 900 W
(3 x 300 W)
1000: 1000 W
(2 x 500 W)
1200: 1200 W
(3 x 400 W)
1500: 1500 W
(3 x 500 W)
12: 12 V
1T: 12 V /
5 & 12 V STBY
AQ:
ACuQor series
of AC-DC
semi-regulated
output power
supplies
24: 24 V
E: 1 unit (3"x5")
2T: 24 V /
R: 2 units; flat
5 & 12 V STBY
S: 2 units; stacked
U: Universal
A: Open frame
C: Encased
Industrial Grade:
IND: Industrial
I: (Industrial)
(85-264 VRMS) 36: 36 V
3T: 36 V /
T: 3 units; flat
U: 3 units; stacked
5 & 12 V STBY
48: 48 V
4T: 48 V /
5 & 12 V STBY
Example: AQ0300IU2TECIND
ACCESSORIES
SynQor offers a series of assemblies that can be ordered according to the table below. Mechanical drawings for these
accessories are available for download in pdf format from the SynQor website.
Part Number
Description
Input mating cable with pre-stripped wire ends (36” long).
Output mating cables with pre-stripped wire ends (18” long).
Same as AQ-CBL -OUT1C with an additional 8-pins connector.
Output mating cable with connectors on both ends (18" long).
Same as the AQ-CBL-OUT2C with an additional 8-pins connector.
Single module bottom-side Mylar insulator for open frame mounting
Evaluation board for up to three paralleled modules.
AQ-CBL-INPUT1C
AQ-CBL-OUT1C
AQ-CBL-OUT1CD
AQ-CBL-OUT2C
AQ-CBL-OUT2CD
AQ-INSUL1M
AQ-EVAL-PRL3
APPLICATION NOTES
A variety of application notes and technical white papers can be downloaded in pdf format from the SynQor website.
Online Application Notes
Online Library of Technical White Papers
SynQor website.
Contact SynQor for further information and to order:
PATENTS
SynQor holds numerous U.S. patents, one or more of which apply to most of its power converter
products. Any that apply to the product(s) listed in this document are identified by markings on
the product(s) or on internal components of the product(s) in accordance with U.S. patent laws.
SynQor’s patents include the following:
Phone:
Toll Free:
Fax:
E-mail:
Web:
978-849-0600
888-567-9596
978-849-0602
power@synqor.com
www.synqor.com
155 Swanson Road
Boxborough, MA 01719
USA
5,999,417
6,896,526
7,269,034
7,787,261
6,222,742
6,927,987
7,272,021
8,023,290
6,545,890
7,050,309
7,272,023
8,149,597
6,594,159
7,072,190
7,558,083
8,493,751
6,731,520
7,085,146
7,564,702
8,644,027
6,894,468
7,119,524
7,765,687
Address:
WARRANTY
SynQor offers a two (2) year limited warranty. Complete warranty
information is listed on our website or is available upon request from SynQor.
Product # AQ0300IUxT
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-005050 Rev. C
08/21/15
Page 14