IQ48400HPC6DNRS [SYNQOR]
Half-brick DC-DC Converter; 半砖DC- DC转换器型号: | IQ48400HPC6DNRS |
厂家: | SYNQOR WORLDWIDE HEADQUARTERS |
描述: | Half-brick DC-DC Converter |
文件: | 总28页 (文件大小:2155K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Technical
Specification
IQ48-HPC Family
34-75 V
100 V
1.8-48 V
Outputs
255 W 2250 V dc
Half-brick
DC-DC Converter
Continuous Input Transient Input
Max Power
Isolation
®
The InQor Half-brick converter series is composed
of next-generation, board-mountable, isolated,
fixed switching frequency dc-dc converters that use
synchronous rectification to achieve extremely high
power conversion efficiency. Each module is supplied
completely encased to provide protection from the
harsh environments seen in many industrial and
transportation applications.
Operational Features
•ꢀ Highꢀefficiencies,ꢀupꢀtoꢀ91%ꢀatꢀfullꢀratedꢀloadꢀcurrent
•ꢀ Deliversꢀfullꢀpowerꢀwithꢀminimalꢀderatingꢀ-ꢀnoꢀheatsinkꢀrequired
•ꢀ Operatingꢀinputꢀvoltageꢀrange:ꢀ
34ꢀ-ꢀ75ꢀV,ꢀ100ꢀVꢀtransientꢀforꢀ100ꢀms
•ꢀ FixedꢀfrequencyꢀswitchingꢀprovidesꢀpredictableꢀEMI
•ꢀ Noꢀminimumꢀloadꢀrequirement
Mechanical Features
Protection Features
•ꢀ IndustryꢀstandardꢀHalf-brickꢀpin-outꢀconfigurationꢀ
•ꢀ Inputꢀunder-voltageꢀlockout
•ꢀ Inputꢀover-voltageꢀshutdown
•ꢀ Size:ꢀ2.390"ꢀxꢀ2.490"ꢀxꢀ0.512"ꢀ
(60.6ꢀxꢀ63.1ꢀxꢀ13.0ꢀmm)
•ꢀ Totalꢀweight:ꢀ5ꢀozꢀ(142ꢀg)
•ꢀ Outputꢀcurrentꢀlimitꢀandꢀshortꢀcircuitꢀprotection
•ꢀ Activeꢀbackꢀbiasꢀlimit
•ꢀ Outputꢀover-voltageꢀprotection
•ꢀ Thermalꢀshutdown
Control Features
•ꢀ On/Offꢀcontrolꢀreferencedꢀtoꢀinputꢀside
•ꢀ Remoteꢀsenseꢀforꢀtheꢀoutputꢀvoltage
•ꢀ Outputꢀvoltageꢀtrimꢀrangeꢀofꢀ-20%,ꢀ+10%
COꢀTꢁꢀTS
ꢀ
PageꢀNo.
MechanicalꢀDrawing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ꢀ2
IQ48-HPCꢀFamilyꢀElectricalꢀCharacteristics . . . . . . . . . . . . . . . . . . . . 3 - 4
IQ48-HPCꢀFamilyꢀFigures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
IQ48018HPC60ꢀ(1.8ꢀV,ꢀ60ꢀA)ꢀCharacteristicsꢀandꢀFigures . . . . . . . . . .6 - 7
IQ48033HPC60ꢀ(3.3ꢀV,ꢀ60ꢀA)ꢀCharacteristicsꢀandꢀFigures . . . . . . . . . .8ꢀ-ꢀ9
IQ48050HPC46ꢀ(5.0ꢀV,ꢀ46ꢀA)ꢀCharacteristicsꢀandꢀFigures . . . . . . . .10ꢀ-ꢀ11
IQ48120HPC21ꢀ(12ꢀV,ꢀ21ꢀA)ꢀCharacteristicsꢀandꢀFigures. . . . . . . . .12ꢀ-ꢀ13
IQ48150HPC17ꢀ(15ꢀV,ꢀ17ꢀA)ꢀCharacteristicsꢀandꢀFigures. . . . . . . . .14ꢀ-ꢀ15
IQ48240HPC10ꢀ(24ꢀV,ꢀ10.5ꢀA)ꢀCharacteristicsꢀandꢀFigures . . . . . . .16ꢀ-ꢀ17
IQ48280HPC09ꢀ(28ꢀV,ꢀ9.0ꢀA)ꢀCharacteristicsꢀandꢀFigures . . . . . . . .18ꢀ-ꢀ19
IQ48400HPC6Dꢀ(40ꢀV,ꢀ6.3ꢀA)ꢀCharacteristicsꢀandꢀFigures . . . . . . . .20ꢀ-ꢀ21
IQ48480HPC5Cꢀ(48ꢀV,ꢀ5.2ꢀA)ꢀCharacteristicsꢀandꢀFigures . . . . . . . .22ꢀ-ꢀ23
ApplicationꢀNotes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ꢀ24ꢀ-ꢀ27
OrderingꢀInformation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Safety Features
•ꢀ 2250ꢀV,ꢀ30ꢀMW input-to-output isolation
•ꢀ UL/cULꢀ60950-1ꢀrecognizedꢀ(USꢀ&ꢀCanada),ꢀ
basic insulation rating
•ꢀ TUVꢀcertifiedꢀtoꢀEN60950-1ꢀ
•ꢀ Meetsꢀ72/23/EECꢀandꢀ93/68/EECꢀdirectivesꢀwhichꢀfacilitatesꢀ
CEꢀMarkingꢀinꢀuser’sꢀendꢀproduct
•ꢀ BoardꢀandꢀplasticꢀcomponentsꢀmeetꢀUL94V-0ꢀstandard
•ꢀ RoHSꢀcompliantꢀ(seeꢀlastꢀpage)
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 1
Technical
Specification
IQ48-HPC Family
MECHANICALꢀDIAGRAM
PINꢀDESIGNATIONS
NOTES
ꢀ
ꢀ
ꢀ
ꢀ
1)ꢀPinsꢀ1-3,ꢀ5-7ꢀareꢀ0.040"ꢀ(1.02ꢀmm)ꢀdiameterꢀwithꢀ0.080"ꢀ
(2.03ꢀmm)ꢀdiameterꢀstandoffꢀshoulders.
Pin
Name
Vinꢀ(+)
Function
No.
2)ꢀPinsꢀ4ꢀandꢀ8ꢀareꢀ0.080”ꢀ(2.03ꢀmm)ꢀdiameterꢀwithꢀ0.125”ꢀ
(3.18ꢀmm)ꢀdiameterꢀstandoffꢀshoulders.
3)ꢀRecommendedꢀpinꢀlengthꢀisꢀ0.03"ꢀ(0.76ꢀmm)ꢀgreaterꢀthanꢀtheꢀ
PCBꢀthickness.
4)ꢀAllꢀPins:ꢀMaterialꢀ-ꢀCopperꢀAlloy;ꢀꢀFinishꢀ-ꢀMatteꢀTinꢀoverꢀNickelꢀ
plate
1
Positive input voltage
TTLꢀinputꢀtoꢀturnꢀconverterꢀ
on and off, referenced to
Vinꢀ(-)ꢀwithꢀinternalꢀpullꢀup
2
ON/OFF
ꢀ
ꢀ
5)ꢀWeight:ꢀ 5ꢀoz.ꢀ(142ꢀg)ꢀtypical
6)ꢀAllꢀdimensionsꢀinꢀinchesꢀ(mm)
Tolerances:ꢀ x.xxꢀꢀ+/-0.02ꢀin.ꢀ(x.xꢀꢀ+/-0.5ꢀmm)
3
4
5
6
7
8
Vinꢀ(-)
Negativeꢀinputꢀvoltage
Negativeꢀoutputꢀvoltage
Voutꢀ(-)
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ ꢀ
ꢀ
x.xxxꢀꢀ+/-0.010ꢀin.ꢀ(x.xxꢀꢀ+/-0.25ꢀmm)
SENSEꢀ(-) Negativeꢀremoteꢀsense1
TRIM
Outputꢀvoltageꢀtrim2
SENSEꢀ(+) Positive remote sense3
Voutꢀ(+) Positive output voltage
7)ꢀWorkmanship:ꢀMeetsꢀorꢀexceedsꢀcurrentꢀIPC-A-610ꢀClassꢀII
8)ꢀAppliedꢀtorqueꢀperꢀscrewꢀshouldꢀnotꢀexceedꢀ6in-lb.ꢀ(0.7ꢀNm).
9)ꢀBaseplateꢀflatnessꢀtoleranceꢀisꢀ0.004"ꢀ(.10ꢀmm)ꢀTIRꢀforꢀsurface.
Notes:
1.ꢀ SENSE(–)ꢀshouldꢀbeꢀconnectedꢀtoꢀVout(–)ꢀeitherꢀremotelyꢀorꢀatꢀtheꢀ
converter.
2.ꢀ LeaveꢀTRIMꢀpinꢀopenꢀforꢀnominalꢀoutputꢀvoltage.
3.ꢀ SENSE(+)ꢀshouldꢀbeꢀconnectedꢀtoꢀVout(+)ꢀeitherꢀremotelyꢀorꢀatꢀtheꢀ
converter.
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 2
Technical
Specification
IQ48-HPC Family
IQ48xxxHPCxx FAMILY ꢁLꢁCTRICAL CHARACTꢁRISTICS (all output voltages)
Taꢀ=ꢀ25ꢀ°C,ꢀairflowꢀrateꢀ=ꢀ300ꢀLFM,ꢀVinꢀ=ꢀ48ꢀVꢀdcꢀunlessꢀotherwiseꢀnoted;ꢀfullꢀoperatingꢀtemperatureꢀrangeꢀisꢀ-40ꢀ°Cꢀtoꢀ+100ꢀ°Cꢀbaseplateꢀ
temperatureꢀwithꢀappropriateꢀpowerꢀderating.ꢀꢀSpecificationsꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
Parameter
Min.
Typ.
Max. Units ꢀotes & Conditions
ABSOLUTꢁ MAXIMUM RATIꢀGS
Input Voltage
ꢀNon-Operating
ꢀOperating
ꢀOperatingꢀTransientꢀProtection
Isolation Voltage
100
75
100
V
V
V
ꢀContinuous
ꢀContinuous
ꢀ100ꢀmsꢀtransient,ꢀsquareꢀwave
ꢀInputꢀtoꢀOutput
2250
2250
2250
100
125
18
V dc
V dc
V dc
°C
°C
V
ꢀInputꢀtoꢀBase-Plate
ꢀOutputꢀtoꢀBase-Plate
ꢀOperatingꢀTemperature
ꢀStorageꢀTemperature
ꢀVoltageꢀatꢀON/OFFꢀinputꢀpin
-40
-55
-2
ꢀBaseplateꢀtemperature
IꢀPUT CHARACTꢁRISTICS
ꢀOperatingꢀInputꢀVoltageꢀRange
ꢀInputꢀUnder-VoltageꢀLockout
34
48
75
V
100Vꢀtransientꢀforꢀ100ꢀms
ꢀTurn-OnꢀVoltageꢀThreshold
ꢀTurn-OffꢀVoltageꢀThreshold
32.7
30.4
33.1
30.8
33.5
31.2
V
V
ꢀLockoutꢀVoltageꢀHysteresis
ꢀInputꢀOver-VoltageꢀShutdown
ꢀRecommendedꢀExternalꢀInputꢀCapacitance
ꢀInputꢀFilterꢀComponentꢀValuesꢀ(L\C)
DYꢀAMIC CHARACTꢁRISTICS
ꢀTurn-OnꢀTransient
2.2
107
100
3.4\4.0
V
V
µF
102
ꢀTypicalꢀESRꢀ0.1-0.2ꢀΩ
µH\µF ꢀInternalꢀvalues;ꢀseeꢀFigureꢀE
ꢀTurn-OnꢀTime
ꢀStart-UpꢀInhibitꢀTime
ꢀOutputꢀVoltageꢀOvershoot
10
230
0
ms
ms
%
ꢀFullꢀload,ꢀVout=90%ꢀnom.
ꢀ-40ꢀ°Cꢀtoꢀ+125ꢀ°C;ꢀFigureꢀF
ꢀMaximumꢀOutputꢀCapacitance
200
250
ISOLATIOꢀ CHARACTꢁRISTICS
ꢀIsolationꢀVoltageꢀ(dielectricꢀstrength)
ꢀIsolationꢀResistance
ꢀSeeꢀAbsoluteꢀMaximumꢀRatings
ꢀSeeꢀNoteꢀ2
30
1000
MΩ
pF
ꢀIsolationꢀCapacitanceꢀ(inputꢀtoꢀoutput)
TꢁMPꢁRATURꢁ LIMITS FOR POWꢁR DꢁRATIꢀG CURVꢁS
ꢀSemiconductorꢀJunctionꢀTemperature
ꢀBoardꢀTemperature
Transformer Temperature
ꢀMaximumꢀBaseplateꢀTemperature,ꢀTb
FꢁATURꢁ CHARACTꢁRISTICS
125
125
125
100
°C
°C
°C
°C
ꢀPackageꢀratedꢀtoꢀ150ꢀ°C
ꢀULꢀratedꢀmaxꢀoperatingꢀtempꢀ130ꢀ°C
ꢀSwitchingꢀFrequency
ꢀON/OFFꢀControl
255
275
295
kHz
Isolation stage switching freq. is half this
ꢀOff-StateꢀVoltage
ꢀOn-StateꢀVoltage
2.4
-2
1.8
0.8
V
ꢀON/OFFꢀControl
ꢀPull-UpꢀVoltage
ꢀPull-UpꢀResistance
ꢀOver-TemperatureꢀShutdownꢀOTPꢀTripꢀPoint
ꢀOver-TemperatureꢀShutdownꢀRestartꢀHysteresis
RꢁLIABILITY CHARACTꢁRISTICS
ꢀCalculatedꢀMTBFꢀ(Telcordia)ꢀTR-NWT-000332
ꢀCalculatedꢀMTBFꢀ(MIL-217)ꢀMIL-HDBK-217F
ꢀFieldꢀDemonstratedꢀMTBF
ꢀApplicationꢀnotesꢀFiguresꢀAꢀ&ꢀB
ꢀAverageꢀPCBꢀTemperature
5
50
125
10
V
kΩ
°C
°C
6
6
6
TBD
TBD
10 Hrs. ꢀ80%ꢀload,ꢀ200LFM,ꢀ40ꢀ°CꢀTa
10 Hrs. ꢀ80%ꢀload,ꢀ200LFM,ꢀ40ꢀ°CꢀTa
10 Hrs. ꢀSeeꢀourꢀwebsiteꢀforꢀdetails
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 3
Technical
Specification
IQ48-HPC Family
STANDARDSꢀCOMPLIANCE
Parameter
ꢀNotesꢀ&ꢀConditions
ꢀSTANDARDSꢀCOMPLIANCE
ꢀUL/cULꢀ60950-1ꢀꢀ
ꢀEN60950-1ꢀꢀ
ꢀFileꢀ#ꢀE194341,ꢀBasicꢀinsulation
ꢀCertifiedꢀbyꢀTUV
ꢀNeedleꢀFlameꢀTestꢀ(IECꢀ695-2-2)
ꢀIECꢀ61000-4-2
ꢀTestꢀonꢀentireꢀassembly;ꢀboardꢀ&ꢀplasticꢀcomponentsꢀUL94V-0ꢀcompliant
ꢀESDꢀtest,ꢀ8ꢀkVꢀ-ꢀNP,ꢀ15ꢀkVꢀairꢀ-ꢀNPꢀ(NormalꢀPerformance)
Note:ꢀAnꢀexternalꢀinputꢀfuseꢀmustꢀalwaysꢀbeꢀusedꢀtoꢀmeetꢀtheseꢀsafetyꢀrequirements.ꢀꢀContactꢀSynQorꢀforꢀofficialꢀsafetyꢀcertificatesꢀonꢀnew
releasesꢀorꢀdownloadꢀfromꢀtheꢀSynQorꢀwebsite.
QUALIFICATIONꢀTESTING
Parameter
#ꢀUnits ꢀTestꢀConditions
ꢀQUALIFICATIONꢀTESTING
ꢀLifeꢀTest
32
ꢀ95%ꢀratedꢀVinꢀandꢀload,ꢀunitsꢀatꢀderatingꢀpoint,ꢀ1000ꢀhours
Vibration
5
5
10
5
5
5
ꢀ10-55ꢀHzꢀsweep,ꢀ0.060"ꢀtotalꢀexcursion,ꢀ1ꢀmin./sweep,ꢀ120ꢀsweepsꢀforꢀ3ꢀaxis
ꢀ100gꢀminimum,ꢀ2ꢀdropsꢀinꢀxꢀandꢀyꢀaxis,ꢀ1ꢀdropꢀinꢀzꢀaxis
ꢀ-40ꢀ°Cꢀtoꢀ100ꢀ°C,ꢀunitꢀtemp.ꢀrampꢀ15ꢀ°C/min.,ꢀ500ꢀcycles
ꢀToperatingꢀ=ꢀminꢀtoꢀmax,ꢀVinꢀ=ꢀminꢀtoꢀmax,ꢀfullꢀload,ꢀ100ꢀcycles
ꢀTmin-10ꢀ°CꢀtoꢀTmax+10ꢀ°C,ꢀ5ꢀ°Cꢀsteps,ꢀVinꢀ=ꢀminꢀtoꢀmax,ꢀ0-105%ꢀload
ꢀ85ꢀ°C,ꢀ85%ꢀRH,ꢀ1000ꢀhours,ꢀcontinuousꢀVinꢀappliedꢀexceptꢀ5ꢀmin/day
ꢀMIL-STD-883,ꢀmethodꢀ2003
ꢀMechanicalꢀShock
ꢀTemperatureꢀCycling
ꢀPower/ThermalꢀCycling
ꢀDesignꢀMarginality
Humidity
ꢀSolderability
15ꢀpins
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 4
Technical
Specification
IQ48-HPC Family
IQ48 FAMILY FIGURꢁS (all output voltages)
120
Typical Current Limit Inception Point
Nominal Vout
100
80
60
40
20
0
Typical Output Voltage at Shutdown
Vin min
Vin nom
Vin max
5.00
0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
Load Current (%)
Common Figure 1: Typical startup waveform. Input voltage pre-applied,
ON/OFF Pin on Ch 2.
Common Figure 2: Output voltage vs. load current showing typical
current limit curves and converter shutdown points.
100,000
10,000
1,000
100
1,000,000
100,000
10,000
1,000
10
100
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
1.8 V
3.3 V
5 V
12 V
15 V
24 V
28 V
40V
48 V
Common Figure 3: Trim graph for trim-up 1.8 to 12 V outputs.
Common Figure 4: Trim graph for trim-up 15 to 48 V outputs.
10,000.0
% Decrease in Vout (All voltages)
1,000.0
100.0
10.0
0
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20
% Decrease in Vout (All voltages)
Common Figure 5: Trim graph for trim down.
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 5
Input34 - 75 V
Output1.8 V
Current60 A
Part ꢀo.IQ48018HPC60
Technical Specification
IQ48018HPC60 ꢁLꢁCTRICAL CHARACTꢁRISTICS (1.8 Vout)
Taꢀ=ꢀ25ꢀ°C,ꢀairflowꢀrateꢀ=ꢀ300ꢀLFM,ꢀVinꢀ=ꢀ48ꢀVꢀdcꢀunlessꢀotherwiseꢀnoted;ꢀfullꢀoperatingꢀtemperatureꢀrangeꢀisꢀ-40ꢀ°Cꢀtoꢀ+100ꢀ°Cꢀbaseplateꢀ
temperatureꢀwithꢀappropriateꢀpowerꢀderating.ꢀꢀSpecificationsꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
Parameter
Min.
Typ.
Max. Units ꢀotes & Conditions
IꢀPUT CHARACTꢁRISTICS
ꢀMaximumꢀInputꢀCurrent
ꢀNo-LoadꢀInputꢀCurrent
5.0
60
2
A
mA
mA
V
ꢀVinꢀmin;ꢀtrimꢀup;ꢀinꢀcurrentꢀlimit
50
1
ꢀDisabledꢀInputꢀCurrent
ꢀResponseꢀtoꢀInputꢀTransient
ꢀInputꢀTerminalꢀRippleꢀCurrent
ꢀRecommendedꢀInputꢀFuse
OUTPUT CHARACTꢁRISTICS
ꢀOutputꢀVoltageꢀSetꢀPoint
ꢀOutputꢀVoltageꢀRegulation
ꢀOverꢀLine
0.12
100
ꢀSeeꢀFigureꢀ6
mA
A
ꢀRMS
20
ꢀFastꢀactingꢀexternalꢀfuseꢀrecommended
1.782
1.8
1.818
V
±0.1
±0.1
±0.3
±0.3
27
%
%
mV
V
ꢀOverꢀLoad
ꢀOverꢀTemperature
-27
ꢀTotalꢀOutputꢀVoltageꢀRange
ꢀOutputꢀVoltageꢀRippleꢀandꢀNoise
Peak-to-Peak
1.755
1.845
ꢀOverꢀsample,ꢀline,ꢀload,ꢀtemperatureꢀ&ꢀlife
ꢀ20ꢀMHzꢀbandwidth;ꢀseeꢀNoteꢀ1
ꢀFullꢀload
0
80
18
160
40
mV
mV
A
ꢀRMS
ꢀFullꢀload
ꢀOperatingꢀOutputꢀCurrentꢀRange
ꢀOutputꢀDCꢀCurrent-LimitꢀInception
ꢀOutputꢀDCꢀCurrent-LimitꢀShutdownꢀVoltage
ꢀBack-DriveꢀCurrentꢀLimitꢀwhileꢀEnabled
ꢀBack-DriveꢀCurrentꢀLimitꢀwhileꢀDisabled
ꢀMaximumꢀOutputꢀCapacitance
ꢀOutputꢀVoltageꢀduringꢀLoadꢀCurrentꢀTransient
ꢀStepꢀChangeꢀinꢀOutputꢀCurrentꢀ(0.1ꢀA/µs)
ꢀSettlingꢀTime
0
60
ꢀSubjectꢀtoꢀthermalꢀderating
ꢀOutputꢀvoltageꢀ10%ꢀLow
66.0
72.0
0.8
0.8
0.1
78.0
A
V
A
ꢀNegativeꢀcurrentꢀdrawnꢀfromꢀoutput
ꢀNegativeꢀcurrentꢀdrawnꢀfromꢀoutput
ꢀVoutꢀnominalꢀatꢀfullꢀloadꢀ(resistiveꢀload)
mA
µF
15,000
70
mV
µs
%
%
V
ꢀ50%ꢀtoꢀ75%ꢀtoꢀ50%ꢀIoutꢀmax
ꢀToꢀwithinꢀ1%ꢀVoutꢀnom
ꢀAcrossꢀPinsꢀ8&4;ꢀCommonꢀFiguresꢀ3-5
ꢀAcrossꢀPinsꢀ8&4
700
ꢀOutputꢀVoltageꢀTrimꢀRange
ꢀOutputꢀVoltageꢀRemoteꢀSenseꢀRange
ꢀOutputꢀOver-VoltageꢀProtection
ꢁFFICIꢁꢀCY
-20
2.1
10
10
2.2
2.3
ꢀOverꢀfullꢀtempꢀrange
ꢀ100%ꢀLoad
85
89
%
%
ꢀSeeꢀFigureꢀ1ꢀforꢀefficiencyꢀcurve
ꢀSeeꢀFigureꢀ1ꢀforꢀefficiencyꢀcurve
ꢀ50%ꢀLoad
Noteꢀ1:ꢀOutputꢀisꢀterminatedꢀwithꢀ1ꢀµFꢀceramicꢀandꢀ15ꢀµFꢀlow-ESRꢀtantalumꢀcapacitors.ꢀꢀForꢀapplicationsꢀrequiringꢀreducedꢀoutputꢀvoltageꢀrippleꢀandꢀ
noise,ꢀconsultꢀSynQorꢀapplicationsꢀsupportꢀ(e-mail:ꢀsupport@synqor.com)
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 6
Input34 - 75 V
Output1.8 V
Current60 A
Part ꢀo.IQ48018HPC60
Technical Specification
100
95
90
85
80
75
70
65
60
24
21
18
15
12
9
6
34 Vin
48 Vin
75 Vin
34 Vin
48 Vin
75 Vin
3
0
0
5
10
15
20
25
30
35
40
45
50
55
60
0
5
10
15
20
25
30
35
40
45
50
55
60
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for
Figure 2: Power dissipation at nominal output voltage vs. load current
minimum, nominal, and maximum input voltage at 25
°C.
for minimum, nominal, and maximum input voltage at 25°C.
70
60
50
40
30
70
60
50
40
30
20
10
0
20
10
0
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
25
40
55
Ambient Air Temperature (°C)
70
85
25
40
55
Ambient Air Temperature (°C)
70
85
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%-
Figure 6: Output voltage response to step-change in input voltage
50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 15 µF Tantalum + 1
µF Ceramic
(1000 V/ms). Load cap: 100
µF, electrolytic output capacitance.
capacitor. Ch 1: Vout (100 mV/div), Ch 2: Iout (20 A/div).
Ch 1: Vout (200 mV/div), Ch 2: Vin (50 V/div).
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 7
Input34 - 75 V
Output3.3 V
Current60 A
Part ꢀo.IQ48033HPC60
Technical Specification
IQ48033HPC60 ꢁLꢁCTRICAL CHARACTꢁRISTICS (3.3 Vout)
Taꢀ=ꢀ25ꢀ°C,ꢀairflowꢀrateꢀ=ꢀ300ꢀLFM,ꢀVinꢀ=ꢀ48ꢀVꢀdcꢀunlessꢀotherwiseꢀnoted;ꢀfullꢀoperatingꢀtemperatureꢀrangeꢀisꢀ-40ꢀ°Cꢀtoꢀ+100ꢀ°Cꢀbaseplateꢀ
temperatureꢀwithꢀappropriateꢀpowerꢀderating.ꢀꢀSpecificationsꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
Parameter
Min.
Typ.
Max. Units ꢀotes & Conditions
IꢀPUT CHARACTꢁRISTICS
ꢀMaximumꢀInputꢀCurrent
ꢀNo-LoadꢀInputꢀCurrent
8.6
80
2
A
mA
mA
V
mA
A
ꢀVinꢀmin;ꢀtrimꢀup;ꢀinꢀcurrentꢀlimit
60
1
0.24
190
ꢀDisabledꢀInputꢀCurrent
ꢀResponseꢀtoꢀInputꢀTransient
ꢀInputꢀTerminalꢀRippleꢀCurrent
ꢀRecommendedꢀInputꢀFuse
OUTPUT CHARACTꢁRISTICS
ꢀOutputꢀVoltageꢀSetꢀPoint
ꢀOutputꢀVoltageꢀRegulation
ꢀOverꢀLine
ꢀOverꢀLoad
ꢀOverꢀTemperature
ꢀTotalꢀOutputꢀVoltageꢀRange
ꢀOutputꢀVoltageꢀRippleꢀandꢀNoise
Peak-to-Peak
ꢀSeeꢀFigureꢀ6
ꢀRMS
ꢀFastꢀactingꢀexternalꢀfuseꢀrecommended
20
3.267
3.3
3.333
V
±0.1
±0.1
±0.3
±0.3
50
%
%
mV
V
-50
3.218
3.383
ꢀOverꢀsample,ꢀline,ꢀload,ꢀtemperatureꢀ&ꢀlife
ꢀ20ꢀMHzꢀbandwidth;ꢀseeꢀNoteꢀ1
ꢀFullꢀload
ꢀFullꢀload
ꢀSubjectꢀtoꢀthermalꢀderating
ꢀOutputꢀvoltageꢀ10%ꢀLow
0
140
23
280
50
60
mV
mV
A
ꢀRMS
ꢀOperatingꢀOutputꢀCurrentꢀRange
ꢀOutputꢀDCꢀCurrent-LimitꢀInception
ꢀOutputꢀDCꢀCurrent-LimitꢀShutdownꢀVoltage
ꢀBack-DriveꢀCurrentꢀLimitꢀwhileꢀEnabled
ꢀBack-DriveꢀCurrentꢀLimitꢀwhileꢀDisabled
ꢀMaximumꢀOutputꢀCapacitance
ꢀOutputꢀVoltageꢀduringꢀLoadꢀCurrentꢀTransient
ꢀStepꢀChangeꢀinꢀOutputꢀCurrentꢀ(0.1ꢀA/µs)
ꢀSettlingꢀTime
ꢀOutputꢀVoltageꢀTrimꢀRange
ꢀOutputꢀVoltageꢀRemoteꢀSenseꢀRange
ꢀOutputꢀOver-VoltageꢀProtection
ꢁFFICIꢁꢀCY
0
66.0
72.0
1.4
1.2
0.1
78.0
A
V
A
mA
µF
ꢀNegativeꢀcurrentꢀdrawnꢀfromꢀoutput
ꢀNegativeꢀcurrentꢀdrawnꢀfromꢀoutput
ꢀVoutꢀnominalꢀatꢀfullꢀloadꢀ(resistiveꢀload)
10,000
80
500
mV
µs
%
%
V
ꢀ50%ꢀtoꢀ75%ꢀtoꢀ50%ꢀIoutꢀmax
ꢀToꢀwithinꢀ1%ꢀVoutꢀnom
ꢀAcrossꢀPinsꢀ8&4;ꢀCommonꢀFiguresꢀ3-5
ꢀAcrossꢀPinsꢀ8&4
-20
3.9
10
10
4.2
4.0
ꢀOverꢀfullꢀtempꢀrange
ꢀ100%ꢀLoad
ꢀ50%ꢀLoad
89
92
%
%
ꢀSeeꢀFigureꢀ1ꢀforꢀefficiencyꢀcurve
ꢀSeeꢀFigureꢀ1ꢀforꢀefficiencyꢀcurve
Noteꢀ1:ꢀOutputꢀisꢀterminatedꢀwithꢀ1ꢀµFꢀceramicꢀandꢀ15ꢀµFꢀlow-ESRꢀtantalumꢀcapacitors.ꢀꢀForꢀapplicationsꢀrequiringꢀreducedꢀoutputꢀvoltageꢀrippleꢀandꢀ
noise,ꢀconsultꢀSynQorꢀapplicationsꢀsupportꢀ(e-mail:ꢀsupport@synqor.com)
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 8
Input34 - 75 V
Output3.3 V
Current60 A
Part ꢀo.IQ48033HPC60
Technical Specification
100
95
90
85
80
75
70
65
60
27
24
21
18
15
12
9
6
34 Vin
48 Vin
75 Vin
34 Vin
48 Vin
75 Vin
3
0
0
5
10
15
20
25
30
35
40
45
50
55
60
0
5
10
15
20
25
30
35
40
45
50
55
60
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for
Figure 2: Power dissipation at nominal output voltage vs. load current
minimum, nominal, and maximum input voltage at 25
°C.
for minimum, nominal, and maximum input voltage at 25°C.
70
60
50
40
30
70
60
50
40
30
20
10
0
20
10
0
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
25
40
55
Ambient Air Temperature (°C)
70
85
25
40
55
Ambient Air Temperature (°C)
70
85
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%-
Figure 6: Output voltage response to step-change in input voltage
50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 15 µF Tantalum + 1
µF Ceramic
(1000 V/ms). Load cap: 100
µF, electrolytic output capacitance.
capacitor. Ch 1: Vout (100 mV/div), Ch 2: Iout (20 A/div).
Ch 1: Vout (500 mV/div), Ch 2: Vin (50 V/div).
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 9
Input34 - 75 V
Output5.0 V
Current46 A
Part ꢀo.IQ48050HPC46
Technical Specification
IQ48050HPC46 ꢁLꢁCTRICAL CHARACTꢁRISTICS (5.0 Vout)
Taꢀ=ꢀ25ꢀ°C,ꢀairflowꢀrateꢀ=ꢀ300ꢀLFM,ꢀVinꢀ=ꢀ48ꢀVꢀdcꢀunlessꢀotherwiseꢀnoted;ꢀfullꢀoperatingꢀtemperatureꢀrangeꢀisꢀ-40ꢀ°Cꢀtoꢀ+100ꢀ°Cꢀbaseplateꢀ
temperatureꢀwithꢀappropriateꢀpowerꢀderating.ꢀꢀSpecificationsꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
Parameter
Min.
Typ.
Max. Units ꢀotes & Conditions
IꢀPUT CHARACTꢁRISTICS
ꢀMaximumꢀInputꢀCurrent
ꢀNo-LoadꢀInputꢀCurrent
10.2
60
2
A
mA
mA
V
mA
A
ꢀVinꢀmin;ꢀtrimꢀup;ꢀinꢀcurrentꢀlimit
50
1
0.4
220
ꢀDisabledꢀInputꢀCurrent
ꢀResponseꢀtoꢀInputꢀTransient
ꢀInputꢀTerminalꢀRippleꢀCurrent
ꢀRecommendedꢀInputꢀFuse
OUTPUT CHARACTꢁRISTICS
ꢀOutputꢀVoltageꢀSetꢀPoint
ꢀOutputꢀVoltageꢀRegulation
ꢀOverꢀLine
ꢀOverꢀLoad
ꢀOverꢀTemperature
ꢀTotalꢀOutputꢀVoltageꢀRange
ꢀOutputꢀVoltageꢀRippleꢀandꢀNoise
Peak-to-Peak
ꢀSeeꢀFigureꢀ6
ꢀRMS
ꢀFastꢀactingꢀexternalꢀfuseꢀrecommended
20
4.95
5
5.05
V
±0.1
±0.1
±0.3
±0.3
75
%
%
mV
V
-75
4.875
5.125
ꢀOverꢀsample,ꢀline,ꢀload,ꢀtemperatureꢀ&ꢀlife
ꢀ20ꢀMHzꢀbandwidth;ꢀseeꢀNoteꢀ1
ꢀFullꢀload
ꢀFullꢀload
ꢀSubjectꢀtoꢀthermalꢀderating
ꢀOutputꢀvoltageꢀ10%ꢀLow
0
130
25
260
50
46
mV
mV
A
ꢀRMS
ꢀOperatingꢀOutputꢀCurrentꢀRange
ꢀOutputꢀDCꢀCurrent-LimitꢀInception
ꢀOutputꢀDCꢀCurrent-LimitꢀShutdownꢀVoltage
ꢀBack-DriveꢀCurrentꢀLimitꢀwhileꢀEnabled
ꢀBack-DriveꢀCurrentꢀLimitꢀwhileꢀDisabled
ꢀMaximumꢀOutputꢀCapacitance
ꢀOutputꢀVoltageꢀduringꢀLoadꢀCurrentꢀTransient
ꢀStepꢀChangeꢀinꢀOutputꢀCurrentꢀ(0.1ꢀA/µs)
ꢀSettlingꢀTime
ꢀOutputꢀVoltageꢀTrimꢀRange
ꢀOutputꢀVoltageꢀRemoteꢀSenseꢀRange
ꢀOutputꢀOver-VoltageꢀProtection
ꢁFFICIꢁꢀCY
0
50.6
55.2
2.1
0.5
0.4
59.8
A
V
A
mA
µF
ꢀNegativeꢀcurrentꢀdrawnꢀfromꢀoutput
ꢀNegativeꢀcurrentꢀdrawnꢀfromꢀoutput
ꢀVoutꢀnominalꢀatꢀfullꢀloadꢀ(resistiveꢀload)
8,000
130
500
mV
µs
%
%
V
ꢀ50%ꢀtoꢀ75%ꢀtoꢀ50%ꢀIoutꢀmax
ꢀToꢀwithinꢀ1%ꢀVoutꢀnom
ꢀAcrossꢀPinsꢀ8&4;ꢀCommonꢀFiguresꢀ3-5
ꢀAcrossꢀPinsꢀ8&4
-20
5.9
10
10
6.4
6.1
ꢀOverꢀfullꢀtempꢀrange
ꢀ100%ꢀLoad
ꢀ50%ꢀLoad
88
92
%
%
ꢀSeeꢀFigureꢀ1ꢀforꢀefficiencyꢀcurve
ꢀSeeꢀFigureꢀ1ꢀforꢀefficiencyꢀcurve
Noteꢀ1:ꢀOutputꢀisꢀterminatedꢀwithꢀ1ꢀµFꢀceramicꢀandꢀ15ꢀµFꢀlow-ESRꢀtantalumꢀcapacitors.ꢀꢀForꢀapplicationsꢀrequiringꢀreducedꢀoutputꢀvoltageꢀrippleꢀandꢀ
noise,ꢀconsultꢀSynQorꢀapplicationsꢀsupportꢀ(e-mail:ꢀsupport@synqor.com)
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 10
Input34 - 75 V
Output5.0 V
Current46 A
Part ꢀo.IQ48050HPC46
Technical Specification
100
95
90
85
80
75
70
65
60
35
30
25
20
15
10
5
34 Vin
48 Vin
75 Vin
34 Vin
48 Vin
75 Vin
0
0
5
10
15
20
25
30
35
40
45
0
5
10
15
20
25
30
35
40
45
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for
Figure 2: Power dissipation at nominal output voltage vs. load current
minimum, nominal, and maximum input voltage at 25
°C.
for minimum, nominal, and maximum input voltage at 25°C.
50
45
40
35
30
25
20
50
45
40
35
30
25
20
15
15
400 LFM (2.0 m/s)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
10
5
10
5
0
0
25
40
55
Ambient Air Temperature (°C)
70
85
25
40
55
Ambient Air Temperature (°C)
70
85
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%-
Figure 6: Output voltage response to step-change in input voltage
50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 15 µF Tantalum + 1
µF Ceramic
(1000 V/ms). Load cap: 100
µF, electrolytic output capacitance.
capacitor. Ch 1: Vout (200 mV/div), Ch 2: Iout (20 A/div).
Ch 1: Vout (500 mV/div), Ch 2: Vin (50 V/div).
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 11
Input34 - 75 V
Output12 V
Current21 A
Part ꢀo.IQ48120HPC21
Technical Specification
IQ48120HPC21 ꢁLꢁCTRICAL CHARACTꢁRISTICS (12 Vout)
Taꢀ=ꢀ25ꢀ°C,ꢀairflowꢀrateꢀ=ꢀ300ꢀLFM,ꢀVinꢀ=ꢀ48ꢀVꢀdcꢀunlessꢀotherwiseꢀnoted;ꢀfullꢀoperatingꢀtemperatureꢀrangeꢀisꢀ-40ꢀ°Cꢀtoꢀ+100ꢀ°Cꢀbaseplateꢀ
temperatureꢀwithꢀappropriateꢀpowerꢀderating.ꢀꢀSpecificationsꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
Parameter
Min.
Typ.
Max. Units ꢀotes & Conditions
IꢀPUT CHARACTꢁRISTICS
ꢀMaximumꢀInputꢀCurrent
ꢀNo-LoadꢀInputꢀCurrent
10.7
90
2
A
mA
mA
V
mA
A
ꢀVinꢀmin;ꢀtrimꢀup;ꢀinꢀcurrentꢀlimit
70
1
0.7
210
ꢀDisabledꢀInputꢀCurrent
ꢀResponseꢀtoꢀInputꢀTransient
ꢀInputꢀTerminalꢀRippleꢀCurrent
ꢀRecommendedꢀInputꢀFuse
OUTPUT CHARACTꢁRISTICS
ꢀOutputꢀVoltageꢀSetꢀPoint
ꢀOutputꢀVoltageꢀRegulation
ꢀOverꢀLine
ꢀOverꢀLoad
ꢀOverꢀTemperature
ꢀTotalꢀOutputꢀVoltageꢀRange
ꢀOutputꢀVoltageꢀRippleꢀandꢀNoise
Peak-to-Peak
ꢀSeeꢀFigureꢀ6
ꢀRMS
ꢀFastꢀactingꢀexternalꢀfuseꢀrecommended
20
11.88
12
12.12
V
±0.1
±0.1
±0.3
±0.3
180
%
%
mV
V
-180
11.700
12.300
ꢀOverꢀsample,ꢀline,ꢀload,ꢀtemperatureꢀ&ꢀlife
ꢀ20ꢀMHzꢀbandwidth;ꢀseeꢀNoteꢀ1
ꢀFullꢀload
ꢀFullꢀload
ꢀSubjectꢀtoꢀthermalꢀderating
ꢀOutputꢀvoltageꢀ10%ꢀLow
0
125
17
250
30
21
mV
mV
A
ꢀRMS
ꢀOperatingꢀOutputꢀCurrentꢀRange
ꢀOutputꢀDCꢀCurrent-LimitꢀInception
ꢀOutputꢀDCꢀCurrent-LimitꢀShutdownꢀVoltage
ꢀBack-DriveꢀCurrentꢀLimitꢀwhileꢀEnabled
ꢀBack-DriveꢀCurrentꢀLimitꢀwhileꢀDisabled
ꢀMaximumꢀOutputꢀCapacitance
ꢀOutputꢀVoltageꢀduringꢀLoadꢀCurrentꢀTransient
ꢀStepꢀChangeꢀinꢀOutputꢀCurrentꢀ(0.1ꢀA/µs)
ꢀSettlingꢀTime
ꢀOutputꢀVoltageꢀTrimꢀRange
ꢀOutputꢀVoltageꢀRemoteꢀSenseꢀRange
ꢀOutputꢀOver-VoltageꢀProtection
ꢁFFICIꢁꢀCY
0
23.1
25.2
5.5
0.5
1
27.3
A
V
A
mA
µF
ꢀNegativeꢀcurrentꢀdrawnꢀfromꢀoutput
ꢀNegativeꢀcurrentꢀdrawnꢀfromꢀoutput
ꢀVoutꢀnominalꢀatꢀfullꢀloadꢀ(resistiveꢀload)
1,500
500
80
mV
µs
%
%
V
ꢀ50%ꢀtoꢀ75%ꢀtoꢀ50%ꢀIoutꢀmax
ꢀToꢀwithinꢀ1%ꢀVoutꢀnom
ꢀAcrossꢀPinsꢀ8&4;ꢀCommonꢀFiguresꢀ3-5;ꢀseeꢀNoteꢀ2
ꢀAcrossꢀPinsꢀ8&4
-20
10
10
15.2
14.0
14.6
ꢀOverꢀfullꢀtempꢀrange
ꢀ100%ꢀLoad
ꢀ50%ꢀLoad
91
93
%
%
ꢀSeeꢀFigureꢀ1ꢀforꢀefficiencyꢀcurve
ꢀSeeꢀFigureꢀ1ꢀforꢀefficiencyꢀcurve
Noteꢀ1:ꢀOutputꢀisꢀterminatedꢀwithꢀ1ꢀµFꢀceramicꢀandꢀ15ꢀµFꢀlow-ESRꢀtantalumꢀcapacitors.ꢀꢀForꢀapplicationsꢀrequiringꢀreducedꢀoutputꢀvoltageꢀrippleꢀandꢀ
noise,ꢀconsultꢀSynQorꢀapplicationsꢀsupportꢀ(e-mail:ꢀsupport@synqor.com)
Noteꢀ2:ꢀTrim-upꢀrangeꢀisꢀlimitedꢀbelowꢀ10%ꢀatꢀlowꢀlineꢀandꢀfullꢀload.
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 12
Input34 - 75 V
Output12 V
Current21 A
Part ꢀo.IQ48120HPC21
Technical Specification
100
95
90
85
80
75
70
65
60
27
24
21
18
15
12
9
6
34 Vin
48 Vin
75 Vin
34 Vin
48 Vin
75 Vin
3
0
0
2
4
6
8
10
12
14
16
18
20
0
2
4
6
8
10
12
14
16
18
20
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for
Figure 2: Power dissipation at nominal output voltage vs. load current
minimum, nominal, and maximum input voltage at 25
°C.
for minimum, nominal, and maximum input voltage at 25°C.
24
21
18
15
12
9
24
21
18
15
12
9
400 LFM (2.0 m/s)
400 LFM (2.0 m/s)
6
6
300 LFM (1.5 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
3
0
3
0
25
40
55
Ambient Air Temperature (°C)
70
85
25
40
55
Ambient Air Temperature (°C)
70
85
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%-
Figure 6: Output voltage response to step-change in input voltage
50% of Iout(max); dI/dt = 0.02 A/µs). Load cap: 15 µF Tantalum + 1
µF Ceramic
(250 V/ms). Load cap: 100 µF, electrolytic output capacitance.
capacitor. Ch 1: Vout (500 mV/div), Ch 2: Iout (5 A/div).
Ch 1: Vout (1 V/div), Ch 2: Vin (20 V/div).
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 13
Input34 - 75 V
Output15 V
Current17 A
Part ꢀo.IQ48150HPC17
Technical Specification
IQ48150HPC17 ꢁLꢁCTRICAL CHARACTꢁRISTICS (15 Vout)
Taꢀ=ꢀ25ꢀ°C,ꢀairflowꢀrateꢀ=ꢀ300ꢀLFM,ꢀVinꢀ=ꢀ48ꢀVꢀdcꢀunlessꢀotherwiseꢀnoted;ꢀfullꢀoperatingꢀtemperatureꢀrangeꢀisꢀ-40ꢀ°Cꢀtoꢀ+100ꢀ°Cꢀbaseplateꢀ
temperatureꢀwithꢀappropriateꢀpowerꢀderating.ꢀꢀSpecificationsꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
Parameter
Min.
Typ.
Max. Units ꢀotes & Conditions
IꢀPUT CHARACTꢁRISTICS
ꢀMaximumꢀInputꢀCurrent
ꢀNo-LoadꢀInputꢀCurrent
10.9
80
3
A
mA
mA
V
mA
A
ꢀVinꢀmin;ꢀtrimꢀup;ꢀinꢀcurrentꢀlimit
60
2
0.9
200
ꢀDisabledꢀInputꢀCurrent
ꢀResponseꢀtoꢀInputꢀTransient
ꢀInputꢀTerminalꢀRippleꢀCurrent
ꢀRecommendedꢀInputꢀFuse
OUTPUT CHARACTꢁRISTICS
ꢀOutputꢀVoltageꢀSetꢀPoint
ꢀOutputꢀVoltageꢀRegulation
ꢀOverꢀLine
ꢀOverꢀLoad
ꢀOverꢀTemperature
ꢀTotalꢀOutputꢀVoltageꢀRange
ꢀOutputꢀVoltageꢀRippleꢀandꢀNoise
Peak-to-Peak
1000ꢀV/ms,ꢀseeꢀFigureꢀ6
ꢀRMS
ꢀFastꢀactingꢀexternalꢀfuseꢀrecommended
20
14.85
15
15.15
V
±0.1
±0.1
±0.3
±0.3
225
%
%
mV
V
-225
14.625
15.375
ꢀOverꢀsample,ꢀline,ꢀload,ꢀtemperatureꢀ&ꢀlife
ꢀ20ꢀMHzꢀbandwidth;ꢀseeꢀNoteꢀ1
ꢀFullꢀload
ꢀFullꢀload
ꢀSubjectꢀtoꢀthermalꢀderating
ꢀOutputꢀvoltageꢀ10%ꢀLow
0
125
19
250
40
17
mV
mV
A
ꢀRMS
ꢀOperatingꢀOutputꢀCurrentꢀRange
ꢀOutputꢀDCꢀCurrent-LimitꢀInception
ꢀOutputꢀDCꢀCurrent-LimitꢀShutdownꢀVoltage
ꢀBack-DriveꢀCurrentꢀLimitꢀwhileꢀEnabled
ꢀBack-DriveꢀCurrentꢀLimitꢀwhileꢀDisabled
ꢀMaximumꢀOutputꢀCapacitance
ꢀOutputꢀVoltageꢀduringꢀLoadꢀCurrentꢀTransient
ꢀStepꢀChangeꢀinꢀOutputꢀCurrentꢀ(0.1ꢀA/µs)
ꢀSettlingꢀTime
ꢀOutputꢀVoltageꢀTrimꢀRange
ꢀOutputꢀVoltageꢀRemoteꢀSenseꢀRange
ꢀOutputꢀOver-VoltageꢀProtection
ꢁFFICIꢁꢀCY
0
18.7
20.4
7
0.35
1.5
22.1
A
V
A
mA
µF
ꢀNegativeꢀcurrentꢀdrawnꢀfromꢀoutput
ꢀNegativeꢀcurrentꢀdrawnꢀfromꢀoutput
ꢀVoutꢀnominalꢀatꢀfullꢀloadꢀ(resistiveꢀload)
1,000
500
80
mV
µs
%
%
V
ꢀ50%ꢀtoꢀ75%ꢀtoꢀ50%ꢀIoutꢀmax
ꢀToꢀwithinꢀ1%ꢀVoutꢀnom
ꢀAcrossꢀPinsꢀ8&4;ꢀCommonꢀFiguresꢀ3-5
ꢀAcrossꢀPinsꢀ8&4
-20
10
10
19.1
17.6
18.3
ꢀOverꢀfullꢀtempꢀrange
ꢀ100%ꢀLoad
ꢀ50%ꢀLoad
91
93
%
%
ꢀSeeꢀFigureꢀ1ꢀforꢀefficiencyꢀcurve
ꢀSeeꢀFigureꢀ1ꢀforꢀefficiencyꢀcurve
Noteꢀ1:ꢀOutputꢀisꢀterminatedꢀwithꢀ1ꢀµFꢀceramicꢀandꢀ15ꢀµFꢀlow-ESRꢀtantalumꢀcapacitors.ꢀꢀForꢀapplicationsꢀrequiringꢀreducedꢀoutputꢀvoltageꢀrippleꢀandꢀ
noise,ꢀconsultꢀSynQorꢀapplicationsꢀsupportꢀ(e-mail:ꢀsupport@synqor.com)
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 14
Input34 - 75 V
Output15 V
Current17 A
Part ꢀo.IQ48150HPC17
Technical Specification
100
95
90
85
80
75
70
65
60
30
27
24
21
18
15
12
9
34 Vin
48 Vin
75 Vin
34 Vin
48 Vin
75 Vin
6
3
0
0
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17
0
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for
Figure 2: Power dissipation at nominal output voltage vs. load current
minimum, nominal, and maximum input voltage at 25
°C.
for minimum, nominal, and maximum input voltage at 25°C.
18
16
14
12
10
8
18
16
14
12
10
8
6
6
400 LFM (2.0 m/s)
400 LFM (2.0 m/s)
4
4
300 LFM (1.5 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
200 LFM (1.0 m/s)
2
2
100 LFM (0.5 m/s)
100 LFM (0.5 m/s)
0
0
25
40
55
70
85
25
40
55
70
85
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%-
Figure 6: Output voltage response to step-change in input voltage
50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 15 µF Tantalum + 1
µF Ceramic)
(1000 V/ms). Load cap: 100 µF, electrolytic output capacitance.
capacitor. Ch 1: Vout (500 mV/div), Ch 2: Iout (5 A/div).
Ch 1: Vout (1 V/div), Ch 2: Vin (50 V/div).
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 15
Input34 - 75 V
Output24 V
Current10.5 A
Part ꢀo.IQ48024HPC10
Technical Specification
IQ48240HPC10 ꢁLꢁCTRICAL CHARACTꢁRISTICS (24 Vout)
Taꢀ=ꢀ25ꢀ°C,ꢀairflowꢀrateꢀ=ꢀ300ꢀLFM,ꢀVinꢀ=ꢀ48ꢀVꢀdcꢀunlessꢀotherwiseꢀnoted;ꢀfullꢀoperatingꢀtemperatureꢀrangeꢀisꢀ-40ꢀ°Cꢀtoꢀ+100ꢀ°Cꢀbaseplateꢀ
temperatureꢀwithꢀappropriateꢀpowerꢀderating.ꢀꢀSpecificationsꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
Parameter
Min.
Typ.
Max. Units ꢀotes & Conditions
IꢀPUT CHARACTꢁRISTICS
ꢀMaximumꢀInputꢀCurrent
ꢀNo-LoadꢀInputꢀCurrent
10.9
70
2
A
mA
mA
V
mA
A
ꢀVinꢀmin;ꢀtrimꢀup;ꢀinꢀcurrentꢀlimit
55
1
1.2
240
ꢀDisabledꢀInputꢀCurrent
ꢀResponseꢀtoꢀInputꢀTransient
ꢀInputꢀTerminalꢀRippleꢀCurrent
ꢀRecommendedꢀInputꢀFuse
OUTPUT CHARACTꢁRISTICS
ꢀOutputꢀVoltageꢀSetꢀPoint
ꢀOutputꢀVoltageꢀRegulation
ꢀOverꢀLine
ꢀOverꢀLoad
ꢀOverꢀTemperature
ꢀTotalꢀOutputꢀVoltageꢀRange
ꢀOutputꢀVoltageꢀRippleꢀandꢀNoise
Peak-to-Peak
ꢀSeeꢀFigureꢀ6
ꢀRMS
ꢀFastꢀactingꢀexternalꢀfuseꢀrecommended
20
23.76
24
24.24
V
±0.1
±0.1
±0.3
±0.3
360
%
%
mV
V
-360
23.40
24.60
ꢀOverꢀsample,ꢀline,ꢀload,ꢀtemperatureꢀ&ꢀlife
ꢀ20ꢀMHzꢀbandwidth;ꢀseeꢀNoteꢀ1
ꢀFullꢀload
ꢀFullꢀload
ꢀSubjectꢀtoꢀthermalꢀderating
ꢀOutputꢀvoltageꢀ10%ꢀLow
0
85
16
170
30
10.5
13.7
mV
mV
A
ꢀRMS
ꢀOperatingꢀOutputꢀCurrentꢀRange
ꢀOutputꢀDCꢀCurrent-LimitꢀInception
ꢀOutputꢀDCꢀCurrent-LimitꢀShutdownꢀVoltage
ꢀBack-DriveꢀCurrentꢀLimitꢀwhileꢀEnabled
ꢀBack-DriveꢀCurrentꢀLimitꢀwhileꢀDisabled
ꢀMaximumꢀOutputꢀCapacitance
ꢀOutputꢀVoltageꢀduringꢀLoadꢀCurrentꢀTransient
ꢀStepꢀChangeꢀinꢀOutputꢀCurrentꢀ(0.1ꢀA/µs)
ꢀSettlingꢀTime
ꢀOutputꢀVoltageꢀTrimꢀRange
ꢀOutputꢀVoltageꢀRemoteꢀSenseꢀRange
ꢀOutputꢀOver-VoltageꢀProtection
ꢁFFICIꢁꢀCY
0
11.6
12.6
13
0.2
2.5
A
V
A
mA
µF
ꢀNegativeꢀcurrentꢀdrawnꢀfromꢀoutput
ꢀNegativeꢀcurrentꢀdrawnꢀfromꢀoutput
ꢀVoutꢀnominalꢀatꢀfullꢀloadꢀ(resistiveꢀload)
400
1300
100
mV
µs
%
%
V
ꢀ50%ꢀtoꢀ75%ꢀtoꢀ50%ꢀIoutꢀmax
ꢀToꢀwithinꢀ1%ꢀVoutꢀnom
ꢀAcrossꢀPinsꢀ8&4;ꢀCommonꢀFiguresꢀ3-5
ꢀAcrossꢀPinsꢀ8&4
-20
10
10
30.5
28.1
29.3
ꢀOverꢀfullꢀtempꢀrange
ꢀ100%ꢀLoad
ꢀ50%ꢀLoad
89
92
%
%
ꢀSeeꢀFigureꢀ1ꢀforꢀefficiencyꢀcurve
ꢀSeeꢀFigureꢀ1ꢀforꢀefficiencyꢀcurve
Noteꢀ1:ꢀOutputꢀisꢀterminatedꢀwithꢀ1ꢀµFꢀceramicꢀandꢀcapacitor.ꢀꢀForꢀapplicationsꢀrequiringꢀreducedꢀoutputꢀvoltageꢀrippleꢀandꢀnoise,ꢀconsultꢀSynQorꢀ
applicationsꢀsupportꢀ(e-mail:ꢀsupport@synqor.com)
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 16
Input34 - 75 V
Output24 V
Current10.5 A
Part ꢀo.IQ48024HPC10
Technical Specification
100
95
90
85
80
75
70
65
60
30
25
20
15
10
5
34 Vin
48 Vin
75 Vin
34 Vin
48 Vin
75 Vin
0
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for
Figure 2: Power dissipation at nominal output voltage vs. load current
minimum, nominal, and maximum input voltage at 25
°C.
for minimum, nominal, and maximum input voltage at 25°C.
11
10
9
11
10
9
8
8
7
7
6
6
5
5
4
4
3
2
1
0
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
3
2
1
0
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
25
40
55
Ambient Air Temperature (°C)
70
85
25
40
55
Ambient Air Temperature (°C)
70
85
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%-
Figure 6: Output voltage response to step-change in input voltage
50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1
µF ceramic capacitor. Ch 1: Vout
(1000 V/ms). Load cap: 100 µF, electrolytic output capacitance.
(1 V/div), Ch 2: Iout (5 A/div).
Ch 1: Vout (1 V/div), Ch 2: Vin (50 V/div).
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 17
Input34 - 75 V
Output28 V
Current9.0 A
Part ꢀo.IQ48280HPC09
Technical Specification
IQ48280HPC09 ꢁLꢁCTRICAL CHARACTꢁRISTICS (28 Vout)
Taꢀ=ꢀ25ꢀ°C,ꢀairflowꢀrateꢀ=ꢀ300ꢀLFM,ꢀVinꢀ=ꢀ48ꢀVꢀdcꢀunlessꢀotherwiseꢀnoted;ꢀfullꢀoperatingꢀtemperatureꢀrangeꢀisꢀ-40ꢀ°Cꢀtoꢀ+100ꢀ°Cꢀbaseplateꢀ
temperatureꢀwithꢀappropriateꢀpowerꢀderating.ꢀꢀSpecificationsꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
Parameter
Min.
Typ.
Max. Units ꢀotes & Conditions
IꢀPUT CHARACTꢁRISTICS
ꢀMaximumꢀInputꢀCurrent
ꢀNo-LoadꢀInputꢀCurrent
10.9
90
2
A
mA
mA
V
mA
A
ꢀVinꢀmin;ꢀtrimꢀup;ꢀinꢀcurrentꢀlimit
70
1
1.2
260
ꢀDisabledꢀInputꢀCurrent
ꢀResponseꢀtoꢀInputꢀTransient
ꢀInputꢀTerminalꢀRippleꢀCurrent
ꢀRecommendedꢀInputꢀFuse
OUTPUT CHARACTꢁRISTICS
ꢀOutputꢀVoltageꢀSetꢀPoint
ꢀOutputꢀVoltageꢀRegulation
ꢀOverꢀLine
ꢀOverꢀLoad
ꢀOverꢀTemperature
ꢀTotalꢀOutputꢀVoltageꢀRange
ꢀOutputꢀVoltageꢀRippleꢀandꢀNoise
Peak-to-Peak
ꢀSeeꢀFigureꢀ6
ꢀRMS
ꢀFastꢀactingꢀexternalꢀfuseꢀrecommended
20
27.72
28
28.28
V
±0.1
±0.1
±0.3
±0.3
420
%
%
mV
V
-420
27.30
28.70
ꢀOverꢀsample,ꢀline,ꢀload,ꢀtemperatureꢀ&ꢀlife
ꢀ20ꢀMHzꢀbandwidth;ꢀseeꢀNoteꢀ1
ꢀFullꢀload
ꢀFullꢀload
ꢀSubjectꢀtoꢀthermalꢀderating
ꢀOutputꢀvoltageꢀ10%ꢀLow
0
125
23
250
50
9
mV
mV
A
ꢀRMS
ꢀOperatingꢀOutputꢀCurrentꢀRange
ꢀOutputꢀDCꢀCurrent-LimitꢀInception
ꢀOutputꢀDCꢀCurrent-LimitꢀShutdownꢀVoltage
ꢀBack-DriveꢀCurrentꢀLimitꢀwhileꢀEnabled
ꢀBack-DriveꢀCurrentꢀLimitꢀwhileꢀDisabled
ꢀMaximumꢀOutputꢀCapacitance
ꢀOutputꢀVoltageꢀduringꢀLoadꢀCurrentꢀTransient
ꢀStepꢀChangeꢀinꢀOutputꢀCurrentꢀ(0.1ꢀA/µs)
ꢀSettlingꢀTime
ꢀOutputꢀVoltageꢀTrimꢀRange
ꢀOutputꢀVoltageꢀRemoteꢀSenseꢀRange
ꢀOutputꢀOver-VoltageꢀProtection
ꢁFFICIꢁꢀCY
0
9.9
10.8
14
0.15
3
11.7
A
V
A
mA
µF
ꢀNegativeꢀcurrentꢀdrawnꢀfromꢀoutput
ꢀNegativeꢀcurrentꢀdrawnꢀfromꢀoutput
ꢀVoutꢀnominalꢀatꢀfullꢀloadꢀ(resistiveꢀload)
250
1500
100
mV
µs
%
%
V
ꢀ50%ꢀtoꢀ75%ꢀtoꢀ50%ꢀIoutꢀmax
ꢀToꢀwithinꢀ1%ꢀVoutꢀnom
ꢀAcrossꢀPinsꢀ8&4;ꢀCommonꢀFiguresꢀ3-5
ꢀAcrossꢀPinsꢀ8&4
-20
10
10
35.6
32.8
34.2
ꢀOverꢀfullꢀtempꢀrange
ꢀ100%ꢀLoad
ꢀ50%ꢀLoad
90
92
%
%
ꢀSeeꢀFigureꢀ1ꢀforꢀefficiencyꢀcurve
ꢀSeeꢀFigureꢀ1ꢀforꢀefficiencyꢀcurve
Noteꢀ1:ꢀOutputꢀisꢀterminatedꢀwithꢀ1ꢀµFꢀceramicꢀandꢀcapacitor.ꢀꢀForꢀapplicationsꢀrequiringꢀreducedꢀoutputꢀvoltageꢀrippleꢀandꢀnoise,ꢀconsultꢀSynQorꢀ
applicationsꢀsupportꢀ(e-mail:ꢀsupport@synqor.com)
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 18
Input34 - 75 V
Output28 V
Current9.0 A
Part ꢀo.IQ48280HPC09
Technical Specification
100
95
90
85
80
75
70
65
60
27
24
21
18
15
12
9
6
34 Vin
48 Vin
75 Vin
34 Vin
48 Vin
75 Vin
3
0
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for
Figure 2: Power dissipation at nominal output voltage vs. load current
minimum, nominal, and maximum input voltage at 25
°C.
for minimum, nominal, and maximum input voltage at 25°C.
10
9
10
9
8
8
7
7
6
6
5
5
4
4
3
3
400 LFM (2.0 m/s)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
2
1
0
2
1
0
25
40
55
Ambient Air Temperature (°C)
70
85
25
40
55
Ambient Air Temperature (°C)
70
85
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%-
Figure 6: Output voltage response to step-change in input voltage
50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1
µF ceramic capacitor. Ch 1: Vout
(1000 V/ms). Load cap: 100 µF, electrolytic output capacitance.
(2 V/div), Ch 2: Iout (2 A/div).
Ch 1: Vout (2 V/div), Ch 2: Vin (50 V/div).
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 19
Input34 - 75 V
Output40 V
Current6.3 A
Part ꢀo.IQ48400HPC6D
Technical Specification
IQ48400HPC6D ꢁLꢁCTRICAL CHARACTꢁRISTICS (40 Vout)
Taꢀ=ꢀ25ꢀ°C,ꢀairflowꢀrateꢀ=ꢀ300ꢀLFM,ꢀVinꢀ=ꢀ48ꢀVꢀdcꢀunlessꢀotherwiseꢀnoted;ꢀfullꢀoperatingꢀtemperatureꢀrangeꢀisꢀ-40ꢀ°Cꢀtoꢀ+100ꢀ°Cꢀbaseplateꢀ
temperatureꢀwithꢀappropriateꢀpowerꢀderating.ꢀꢀSpecificationsꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
Parameter
Min.
Typ.
Max. Units ꢀotes & Conditions
IꢀPUT CHARACTꢁRISTICS
ꢀMaximumꢀInputꢀCurrent
ꢀNo-LoadꢀInputꢀCurrent
10.9
80
2
A
mA
mA
V
mA
A
ꢀVinꢀmin;ꢀtrimꢀup;ꢀinꢀcurrentꢀlimit
60
1
1.4
240
ꢀDisabledꢀInputꢀCurrent
ꢀResponseꢀtoꢀInputꢀTransient
ꢀInputꢀTerminalꢀRippleꢀCurrent
ꢀRecommendedꢀInputꢀFuse
OUTPUT CHARACTꢁRISTICS
ꢀOutputꢀVoltageꢀSetꢀPoint
ꢀOutputꢀVoltageꢀRegulation
ꢀOverꢀLine
ꢀOverꢀLoad
ꢀOverꢀTemperature
ꢀTotalꢀOutputꢀVoltageꢀRange
ꢀOutputꢀVoltageꢀRippleꢀandꢀNoise
Peak-to-Peak
ꢀSeeꢀFigureꢀ6
ꢀRMS
ꢀFastꢀactingꢀexternalꢀfuseꢀrecommended
20
39.6
40
40.4
V
±0.1
±0.1
±0.3
±0.3
600
%
%
mV
V
-600
39.00
41.00
ꢀOverꢀsample,ꢀline,ꢀload,ꢀtemperatureꢀ&ꢀlife
ꢀ20ꢀMHzꢀbandwidth;ꢀseeꢀNoteꢀ1
ꢀFullꢀload
ꢀFullꢀload
ꢀSubjectꢀtoꢀthermalꢀderating
ꢀOutputꢀvoltageꢀ10%ꢀLow
0
130
27
260
50
6.3
8.2
mV
mV
A
ꢀRMS
ꢀOperatingꢀOutputꢀCurrentꢀRange
ꢀOutputꢀDCꢀCurrent-LimitꢀInception
ꢀOutputꢀDCꢀCurrent-LimitꢀShutdownꢀVoltage
ꢀBack-DriveꢀCurrentꢀLimitꢀwhileꢀEnabled
ꢀBack-DriveꢀCurrentꢀLimitꢀwhileꢀDisabled
ꢀMaximumꢀOutputꢀCapacitance
ꢀOutputꢀVoltageꢀduringꢀLoadꢀCurrentꢀTransient
ꢀStepꢀChangeꢀinꢀOutputꢀCurrentꢀ(0.1ꢀA/µs)
ꢀSettlingꢀTime
ꢀOutputꢀVoltageꢀTrimꢀRange
ꢀOutputꢀVoltageꢀRemoteꢀSenseꢀRange
ꢀOutputꢀOver-VoltageꢀProtection
ꢁFFICIꢁꢀCY
0
6.9
7.6
20
0.1
4
A
V
A
mA
µF
ꢀNegativeꢀcurrentꢀdrawnꢀfromꢀoutput
ꢀNegativeꢀcurrentꢀdrawnꢀfromꢀoutput
ꢀVoutꢀnominalꢀatꢀfullꢀloadꢀ(resistiveꢀload)
150
2300
80
mV
µs
%
%
V
ꢀ50%ꢀtoꢀ75%ꢀtoꢀ50%ꢀIoutꢀmax
ꢀToꢀwithinꢀ1%ꢀVoutꢀnom
ꢀAcrossꢀPinsꢀ8&4;ꢀCommonꢀFiguresꢀ3-5
ꢀAcrossꢀPinsꢀ8&4
-20
10
10
50.8
46.8
48.8
ꢀOverꢀfullꢀtempꢀrange
ꢀ100%ꢀLoad
ꢀ50%ꢀLoad
90
93
%
%
ꢀSeeꢀFigureꢀ1ꢀforꢀefficiencyꢀcurve
ꢀSeeꢀFigureꢀ1ꢀforꢀefficiencyꢀcurve
Noteꢀ1:ꢀOutputꢀisꢀterminatedꢀwithꢀ1ꢀµFꢀceramicꢀandꢀcapacitor.ꢀꢀForꢀapplicationsꢀrequiringꢀreducedꢀoutputꢀvoltageꢀrippleꢀandꢀnoise,ꢀconsultꢀSynQorꢀ
applicationsꢀsupportꢀ(e-mail:ꢀsupport@synqor.com)
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 20
Input34 - 75 V
Output40 V
Current6.3 A
Part ꢀo.IQ48400HPC6D
Technical Specification
100
95
90
85
80
75
70
65
60
35
30
25
20
15
10
5
34 Vin
48 Vin
75 Vin
34 Vin
48 Vin
75 Vin
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5
Load Current (A)
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for
Figure 2: Power dissipation at nominal output voltage vs. load current
minimum, nominal, and maximum input voltage at 25
°C.
for minimum, nominal, and maximum input voltage at 25°C.
7.0
6.3
5.6
4.9
4.2
3.5
2.8
7.0
6.3
5.6
4.9
4.2
3.5
2.8
2.1
2.1
400 LFM (2.0 m/s)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
1.4
0.7
0.0
1.4
0.7
0.0
25
40
55
Ambient Air Temperature (°C)
70
85
25
40
55
Ambient Air Temperature (°C)
70
85
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%-
Figure 6: Output voltage response to step-change in input voltage
50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1
µF ceramic capacitor. Ch 1: Vout
(1000 V/ms). Load cap: 100 µF, electrolytic output capacitance.
(2 V/div), Ch 2: Iout (2 A/div).
Ch 1: Vout (2 V/div), Ch 2: Vin (50 V/div).
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 21
Input34 - 75 V
Output48 V
Current5.2 A
Part ꢀo.IQ48480HPC5C
Technical Specification
IQ48480HPC5C ꢁLꢁCTRICAL CHARACTꢁRISTICS (48 Vout)
Taꢀ=ꢀ25ꢀ°C,ꢀairflowꢀrateꢀ=ꢀ300ꢀLFM,ꢀVinꢀ=ꢀ48ꢀVꢀdcꢀunlessꢀotherwiseꢀnoted;ꢀfullꢀoperatingꢀtemperatureꢀrangeꢀisꢀ-40ꢀ°Cꢀtoꢀ+100ꢀ°Cꢀbaseplateꢀ
temperatureꢀwithꢀappropriateꢀpowerꢀderating.ꢀꢀSpecificationsꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
Parameter
Min.
Typ.
Max. Units ꢀotes & Conditions
IꢀPUT CHARACTꢁRISTICS
ꢀMaximumꢀInputꢀCurrent
ꢀNo-LoadꢀInputꢀCurrent
10.7
90
2
A
mA
mA
V
mA
A
ꢀVinꢀmin;ꢀtrimꢀup;ꢀinꢀcurrentꢀlimit
70
1
1.4
200
ꢀDisabledꢀInputꢀCurrent
ꢀResponseꢀtoꢀInputꢀTransient
ꢀInputꢀTerminalꢀRippleꢀCurrent
ꢀRecommendedꢀInputꢀFuse
OUTPUT CHARACTꢁRISTICS
ꢀOutputꢀVoltageꢀSetꢀPoint
ꢀOutputꢀVoltageꢀRegulation
ꢀOverꢀLine
ꢀOverꢀLoad
ꢀOverꢀTemperature
ꢀTotalꢀOutputꢀVoltageꢀRange
ꢀOutputꢀVoltageꢀRippleꢀandꢀNoise
Peak-to-Peak
ꢀSeeꢀFigureꢀ6
ꢀRMS
ꢀFastꢀactingꢀexternalꢀfuseꢀrecommended
20
47.52
48
48.48
V
±0.1
±0.1
±0.3
±0.3
720
%
%
mV
V
-720
46.80
49.20
ꢀOverꢀsample,ꢀline,ꢀload,ꢀtemperatureꢀ&ꢀlife
ꢀ20ꢀMHzꢀbandwidth;ꢀseeꢀNoteꢀ1
ꢀFullꢀload
ꢀFullꢀload
ꢀSubjectꢀtoꢀthermalꢀderating
ꢀOutputꢀvoltageꢀ10%ꢀLow
0
70
11
140
20
5.2
6.8
mV
mV
A
ꢀRMS
ꢀOperatingꢀOutputꢀCurrentꢀRange
ꢀOutputꢀDCꢀCurrent-LimitꢀInception
ꢀOutputꢀDCꢀCurrent-LimitꢀShutdownꢀVoltage
ꢀBack-DriveꢀCurrentꢀLimitꢀwhileꢀEnabled
ꢀBack-DriveꢀCurrentꢀLimitꢀwhileꢀDisabled
ꢀMaximumꢀOutputꢀCapacitance
ꢀOutputꢀVoltageꢀduringꢀLoadꢀCurrentꢀTransient
ꢀStepꢀChangeꢀinꢀOutputꢀCurrentꢀ(0.1ꢀA/µs)
ꢀSettlingꢀTime
ꢀOutputꢀVoltageꢀTrimꢀRange
ꢀOutputꢀVoltageꢀRemoteꢀSenseꢀRange
ꢀOutputꢀOver-VoltageꢀProtection
ꢁFFICIꢁꢀCY
0
5.7
6.2
23
0.1
5
A
V
A
mA
µF
ꢀNegativeꢀcurrentꢀdrawnꢀfromꢀoutput
ꢀNegativeꢀcurrentꢀdrawnꢀfromꢀoutput
ꢀVoutꢀnominalꢀatꢀfullꢀloadꢀ(resistiveꢀload)
100
2700
80
mV
µs
%
%
V
ꢀ50%ꢀtoꢀ75%ꢀtoꢀ50%ꢀIoutꢀmax
ꢀToꢀwithinꢀ1%ꢀVoutꢀnom
ꢀAcrossꢀPinsꢀ8&4;ꢀCommonꢀFiguresꢀ3-5
ꢀAcrossꢀPinsꢀ8&4
-20
10
10
61.0
56.2
58.6
ꢀOverꢀfullꢀtempꢀrange
ꢀ100%ꢀLoad
ꢀ50%ꢀLoad
90
93
%
%
ꢀSeeꢀFigureꢀ1ꢀforꢀefficiencyꢀcurve
ꢀSeeꢀFigureꢀ1ꢀforꢀefficiencyꢀcurve
Noteꢀ1:ꢀOutputꢀisꢀterminatedꢀwithꢀ1ꢀµFꢀceramicꢀandꢀcapacitor.ꢀꢀForꢀapplicationsꢀrequiringꢀreducedꢀoutputꢀvoltageꢀrippleꢀandꢀnoise,ꢀconsultꢀSynQorꢀ
applicationsꢀsupportꢀ(e-mail:ꢀsupport@synqor.com)
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 22
Input34 - 75 V
Output48 V
Current5.2 A
Part ꢀo.IQ48480HPC5C
Technical Specification
100
95
90
85
80
75
70
65
60
35
30
25
20
15
10
5
34 Vin
48 Vin
75 Vin
34 Vin
48 Vin
75 Vin
0
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for
Figure 2: Power dissipation at nominal output voltage vs. load current
minimum, nominal, and maximum input voltage at 25
°C.
for minimum, nominal, and maximum input voltage at 25°C.
6.0
5.0
4.0
3.0
6.0
5.0
4.0
3.0
2.0
2.0
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
1.0
1.0
200 LFM (1.0 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
100 LFM (0.5 m/s)
0.0
0.0
25
40
55
70
85
25
40
55
70
85
Ambient Air Temperature (°C)
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%-
Figure 6: Output voltage response to step-change in input voltage
50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1
µF ceramic capacitor. Ch 1: Vout
(1000 V/ms). Load cap: 100 µF, electrolytic output capacitance.
(2 V/div), Ch 2: Iout (2 A/div).
Ch 1: Vout (1 V/div), Ch 2: Vin (50 V/div).
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 23
Technical
Specification
IQ48-HPC Family
BASICꢀOPERATIONꢀANDꢀFEATURES
CONTROLꢀFEATURES
This converter series uses a two-stage power conversion
topology. The first stage is a buck-converter that keeps the
output voltage constant over variations in line, load, and
temperature. The second stage uses a transformer to provide
theꢀ functionsꢀ ofꢀ input/outputꢀ isolationꢀ andꢀ voltageꢀ step-upꢀ orꢀ
step-down to achieve the output voltage required.
RꢁMOTꢁ Oꢀ/OFF (Pin 2):ꢀTheꢀON/OFFꢀinput,ꢀPinꢀ2,ꢀpermitsꢀ
the user to control when the converter is on or off. This input
isꢀ referencedꢀ toꢀ theꢀ returnꢀ terminalꢀ ofꢀ theꢀ inputꢀ bus,ꢀ Vin(-).ꢀ
TheꢀON/OFFꢀsignalꢀisꢀactiveꢀlowꢀ(meaningꢀthatꢀaꢀlowꢀturnsꢀtheꢀ
converterꢀon).ꢀFigureꢀAꢀdetailsꢀfourꢀpossibleꢀcircuitsꢀforꢀdrivingꢀ
theꢀON/OFFꢀpin.ꢀFigureꢀBꢀisꢀaꢀdetailedꢀlookꢀofꢀtheꢀinternalꢀON/
OFFꢀcircuitry.
Bothꢀ theꢀ firstꢀ stageꢀ andꢀ theꢀ secondꢀ stageꢀ switchꢀ atꢀ aꢀ fixedꢀ
frequencyꢀ forꢀ predictableꢀ EMIꢀ performance.ꢀ Rectificationꢀ ofꢀ
theꢀ transformer’sꢀ outputꢀ isꢀ accomplishedꢀ withꢀ synchronousꢀ
rectifiers.ꢀ Theseꢀ devices,ꢀ whichꢀ areꢀ MOSFETsꢀ withꢀ aꢀ veryꢀ lowꢀ
on-stateꢀ resistance,ꢀ dissipateꢀ farꢀ lessꢀ energyꢀ thanꢀ Schottkyꢀ
diodes. This is the primary reason that the converter has such
high efficiency, even at very low output voltages and very high
output currents.
RꢁMOTꢁ SꢁꢀSꢁ(+) (Pins 7 and 5):ꢀ Theꢀ SENSE(+)ꢀ inputsꢀ
correct for voltage drops along the conductors that connect the
converter’sꢀoutputꢀpinsꢀtoꢀtheꢀload.
Pinꢀ 7ꢀ shouldꢀ beꢀ connectedꢀ toꢀ Vout(+)ꢀ andꢀ Pinꢀ 5ꢀ shouldꢀ beꢀ
connectedꢀtoꢀVout(-)ꢀatꢀtheꢀpointꢀonꢀtheꢀboardꢀwhereꢀregulationꢀ
isꢀ desired.ꢀ Aꢀ remoteꢀ connectionꢀ atꢀ theꢀ loadꢀ canꢀ adjustꢀ forꢀ aꢀ
voltage drop only as large as that specified in this datasheet,
that is
These converters are offered totally encased to withstand harsh
environmentsꢀandꢀthermallyꢀdemandingꢀapplications.ꢀDissipationꢀ
throughout the converter is so low that it does not require a
heatsinkꢀ forꢀ operationꢀ inꢀ manyꢀ applications;ꢀ however,ꢀ addingꢀ
a heatsink provides improved thermal derating performance in
extreme situations.
[Vout(+)ꢀ-ꢀVout(-)]ꢀ–ꢀ[Vsense(+)ꢀ-ꢀVsense(-)] <
SenseꢀRangeꢀ%ꢀxꢀVout
Pins 7 and 5 must be connected for proper regulation of
the output voltage. If these connections are not made, the
converter will deliver an output voltage that is slightly higher
than its specified value.
This series of converters use the industry standard footprint and
pin-out configuration.
Note:ꢀ theꢀ outputꢀ over-voltageꢀ protectionꢀ circuitꢀ sensesꢀ theꢀ
voltageꢀ acrossꢀ theꢀ outputꢀ (pinsꢀ 8ꢀ andꢀ 4)ꢀ toꢀ determineꢀ whenꢀ
itꢀ shouldꢀ trigger,ꢀ notꢀ theꢀ voltageꢀ acrossꢀ theꢀ converter’sꢀ senseꢀ
leadsꢀ(pinsꢀ7ꢀandꢀ5).ꢀꢀTherefore,ꢀtheꢀresistiveꢀdropꢀonꢀtheꢀboardꢀ
shouldꢀ beꢀ smallꢀ enoughꢀ soꢀ thatꢀ outputꢀ OVPꢀ doesꢀ notꢀ trigger,ꢀ
even during load transients.
ON/OFF
ON/OFF
5V
_
_
Vin( )
Vin( )
NegativeꢀLogic
(PermanentlyꢀEnabled)
RemoteꢀEnableꢀCircuit
50k
5V
ON/OFF
ON/OFF
50k
TTL
TTL/
CMOS
ON/OFF
100pF
_
Vin( )
_
_
Vin( )
Vin( )
OpenꢀCollectorꢀEnableꢀCircuit
DirectꢀLogicꢀDrive
Figure A: Various circuits for driving the ON/OFF pin.
Figure B: Internal ON/OFF pin circuitry
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 24
Technical
Specification
IQ48-HPC Family
OUTPUT VOLTAGꢁ TRIM (Pin 6):ꢀTheꢀTRIMꢀinputꢀpermitsꢀtheꢀ
userꢀtoꢀadjustꢀtheꢀoutputꢀvoltageꢀacrossꢀtheꢀsenseꢀleadsꢀupꢀorꢀ
down according to the trim range specifications.
PROTECTIONꢀFEATURES
Input Under-Voltage Lockout:ꢀ Theꢀ converterꢀ isꢀ designedꢀ
to turn off when the input voltage is too low, helping avoid an
input system instability problem, described in more detail in
the application note titled “Inputꢀ Systemꢀ Instability”ꢀ onꢀ ourꢀ
website. The lockout circuitry is a comparator with dc hysteresis.
Whenꢀtheꢀinputꢀvoltageꢀisꢀrising,ꢀitꢀmustꢀexceedꢀtheꢀtypicalꢀTurn-
OnꢀVoltageꢀThresholdꢀvalueꢀ(listedꢀonꢀtheꢀspecificationsꢀpage)ꢀ
beforeꢀ theꢀ converterꢀ willꢀ turnꢀ on.ꢀ Onceꢀ theꢀ converterꢀ isꢀ on,ꢀ
theꢀ inputꢀ voltageꢀ mustꢀ fallꢀ belowꢀ theꢀ typicalꢀ Turn-Offꢀ Voltageꢀ
Threshold value before the converter will turn off.
To decrease the output voltage, the user should connect a
resistorꢀbetweenꢀPinꢀ6ꢀandꢀPinꢀ5ꢀ(SENSE(-)ꢀinput).ꢀForꢀaꢀdesiredꢀ
decrease of the nominal output voltage, the value of the resistor
should be
511
R
=
-ꢀ10.22 (kW)
trim-down
(∆%)
where
Vnominalꢀ–ꢀVdesired
Output Current Limit:ꢀ Theꢀ maximumꢀ currentꢀ limitꢀ remainsꢀ
constant as the output voltage drops. However, once the
impedance of the load across the output is small enough to make
theꢀoutputꢀvoltageꢀdropꢀbelowꢀtheꢀspecifiedꢀOutputꢀDCꢀCurrent-
LimitꢀShutdownꢀVoltage,ꢀtheꢀconverterꢀturnsꢀoff.
=
xꢀ100%
∆%
Vnominal
To increase the output voltage, the user should connect a
resistorꢀbetweenꢀPinꢀ6ꢀandꢀPinꢀ7ꢀ(SENSE(+)ꢀinput).ꢀForꢀaꢀdesiredꢀ
increase of the nominal output voltage, the value of the resistor
should be
Theꢀconverterꢀthenꢀentersꢀaꢀ“hiccupꢀmode”ꢀwhereꢀitꢀrepeatedlyꢀ
turnsꢀonꢀandꢀoffꢀatꢀaꢀ5ꢀHzꢀ(nominal)ꢀfrequencyꢀwithꢀaꢀ5%ꢀdutyꢀ
cycle until the short circuit condition is removed. This prevents
excessive heating of the converter or the load board.
5.11VOUTꢀ (100+∆%)
x
511
_
R
_
=
(kW)
trim-up
10.22
)
(
1.225∆%
∆%
Output Over-Voltage Limit:ꢀIfꢀtheꢀvoltageꢀacrossꢀtheꢀoutputꢀ
pinsꢀexceedsꢀtheꢀOutputꢀOver-VoltageꢀProtectionꢀthreshold,ꢀtheꢀ
converter will immediately stop switching. This prevents damage
toꢀtheꢀloadꢀcircuitꢀdueꢀtoꢀ1)ꢀexcessiveꢀseriesꢀresistanceꢀinꢀoutputꢀ
currentꢀ pathꢀ fromꢀ converterꢀ outputꢀ pinsꢀ toꢀ senseꢀ point,ꢀ 2)ꢀ aꢀ
releaseꢀofꢀaꢀshort-circuitꢀcondition,ꢀorꢀ3)ꢀaꢀreleaseꢀofꢀaꢀcurrentꢀ
limitꢀ condition.ꢀ Loadꢀ capacitanceꢀ determinesꢀ exactlyꢀ howꢀ highꢀ
theꢀoutputꢀvoltageꢀwillꢀriseꢀinꢀresponseꢀtoꢀtheseꢀconditions.ꢀAfterꢀ
200ꢀmsꢀtheꢀconverterꢀwillꢀautomaticallyꢀrestart.
where
V
ꢀ=ꢀNominalꢀOutputꢀVoltage
out
Trim graphs show the relationship between the trim resistor
valueꢀandꢀRtrim-upꢀandꢀRtrim-down,ꢀshowingꢀtheꢀtotalꢀrangeꢀtheꢀ
output voltage can be trimmed up or down.
Note:ꢀtheꢀTRIMꢀfeatureꢀdoesꢀnotꢀaffectꢀtheꢀvoltageꢀatꢀwhichꢀtheꢀ
output over-voltage protection circuit is triggered. Trimming the
output voltage too high may cause the over-voltage protection
circuit to engage, particularly during transients.
Over-Temperature Shutdown:ꢀ Aꢀ temperatureꢀ sensorꢀ onꢀ
the converter senses the average temperature of the module.
The thermal shutdown circuit is designed to turn the converter
off when the temperature at the sensed location reaches the
Over-Temperatureꢀ Shutdownꢀ value.ꢀ Itꢀ willꢀ allowꢀ theꢀ converterꢀ
to turn on again when the temperature of the sensed location
fallsꢀbyꢀtheꢀamountꢀofꢀtheꢀOver-TemperatureꢀShutdownꢀRestartꢀ
Hysteresis value.
It is not necessary for the user to add capacitance at the Trim
pin. The node is internally bypassed to eliminate noise.
Total DC Variation of V
specifications, the maximum variation of the dc value of V
:ꢀForꢀtheꢀconverterꢀtoꢀmeetꢀitsꢀfullꢀ
OUT
, due
OUT
to both trimming and remote load voltage drops, should not be
greater than that specified for the output voltage trim range.
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 25
Technical
Specification
IQ48-HPC Family
Startup Inhibit Period:ꢀTheꢀStartupꢀInhibitꢀPeriodꢀensuresꢀthatꢀ
theꢀconverterꢀwillꢀremainꢀoffꢀforꢀapproximatelyꢀ200ꢀmsꢀwhenꢀitꢀisꢀ
shutꢀdownꢀforꢀanyꢀreason.ꢀꢀWhenꢀanꢀoutputꢀshortꢀisꢀpresent,ꢀthisꢀ
generatesꢀ aꢀ 5ꢀ Hzꢀ “hiccupꢀ mode,”ꢀ whichꢀ preventsꢀ theꢀ converterꢀ
from overheating. In all, there are seven ways that the converter
canꢀbeꢀshutꢀdown,ꢀinitiatingꢀaꢀStartupꢀInhibitꢀPeriod:
APPLICATIONꢀCONSIDERATIONS
Input System Instability: This condition can occur because
any dc-dc converter appears incrementally as a negative
resistanceꢀ load.ꢀ Aꢀ detailedꢀ applicationꢀ noteꢀ titledꢀ “Input
SystemꢀInstability”ꢀisꢀavailableꢀonꢀtheꢀSynQorꢀwebsite which
provides an understanding of why this instability arises, and
shows the preferred solution for correcting it.
•ꢀ InputꢀUnder-VoltageꢀLockout
•ꢀ InputꢀOver-VoltageꢀShutdown
•ꢀ OutputꢀOver-VoltageꢀProtection
•ꢀ OverꢀTemperatureꢀShutdown
•ꢀ CurrentꢀLimit
Application Circuits:ꢀ Figureꢀ Dꢀ providesꢀ aꢀ typicalꢀ ꢀ circuitꢀ
diagram which details the input filtering and voltage trimming.
Input Filtering and ꢁxternal Capacitance: FigureꢀE provides
a diagram showing the internal input filter components. This filter
dramatically reduces input terminal ripple current, which otherwise
could exceed the rating of an external electrolytic input capacitor.
The recommended external input capacitance is specified in the
Inputꢀ Characteristicsꢀ sectionꢀ onꢀ theꢀ Electricalꢀ Characteristicsꢀ
page.ꢀ ꢀ Moreꢀ detailedꢀ informationꢀ isꢀ availableꢀ inꢀ theꢀ applicationꢀ
note titled “EMIꢀCharacteristics”ꢀonꢀtheꢀSynQorꢀwebsite.
•ꢀ ShortꢀCircuitꢀProtection
•ꢀ TurnedꢀoffꢀbyꢀtheꢀON/OFFꢀinput
FigureꢀFꢀshowsꢀthreeꢀturn-onꢀscenarios,ꢀwhereꢀaꢀStartupꢀInhibitꢀ
Period is initiated at t0, t1, and t2:
Vout(+)
Vin(+)
Vsense(+)
Electrolytic
Capacitor
External
Input
Filter
R
trim-up
or
Vin
Trim
ON/OFF
C
R
load
trim-down
Iload
_
Vsense( )
_
_
Vin( )
Vout( )
Figure D: Typical application circuit (negative logic unit, permanently enabled).
L
Vin(+)
C
_
Vin( )
Figure E: Internal Input Filter Diagram (component values listed on the specifications page).
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 26
Technical
Specification
IQ48-HPC Family
Beforeꢀtimeꢀt0,ꢀwhenꢀtheꢀinputꢀvoltageꢀisꢀbelowꢀtheꢀUVLꢀthreshold,ꢀ
theꢀunitꢀisꢀdisabledꢀbyꢀtheꢀInputꢀUnder-VoltageꢀLockoutꢀfeature.ꢀ
Whenꢀ theꢀ inputꢀ voltageꢀ risesꢀ aboveꢀ theꢀ UVLꢀthreshold,ꢀ theꢀ
InputꢀUnder-VoltageꢀLockoutꢀisꢀreleased,ꢀandꢀaꢀStartupꢀInhibitꢀ
Periodꢀisꢀinitiated.ꢀꢀAtꢀtheꢀendꢀofꢀthisꢀdelay,ꢀtheꢀON/OFFꢀpinꢀisꢀ
evaluated, and since it is active, the unit turns on.
maximum power the converter can dissipate for a given thermal
conditionꢀifꢀitsꢀbase-plateꢀisꢀtoꢀbeꢀnoꢀhigherꢀthanꢀ100ꢀºC.
100 ºCꢀ-ꢀTA
Pmax
=
dissꢀꢀꢀꢀꢀꢀꢀRTH
BA
Thisꢀvalueꢀofꢀpowerꢀdissipationꢀcanꢀthenꢀbeꢀusedꢀinꢀconjunctionꢀ
withꢀtheꢀdataꢀshownꢀinꢀFigureꢀ2ꢀtoꢀdetermineꢀtheꢀmaximumꢀloadꢀ
currentꢀ(andꢀpower)ꢀthatꢀtheꢀconverterꢀcanꢀdeliverꢀinꢀtheꢀgivenꢀ
thermal condition.
Atꢀtimeꢀt1,ꢀtheꢀunitꢀisꢀdisabledꢀbyꢀtheꢀON/OFFꢀpin,ꢀandꢀitꢀcannotꢀ
beꢀenabledꢀagainꢀuntilꢀtheꢀStartupꢀInhibitꢀPeriodꢀhasꢀelapsed.
Whenꢀ theꢀ ON/OFFꢀ pinꢀ goesꢀ highꢀ afterꢀ t2,ꢀ theꢀ Startupꢀ Inhibitꢀ
Period has elapsed, and the output turns on within the typical
Turn-OnꢀTime.
Forꢀconvenience,ꢀpowerꢀderatingꢀcurvesꢀforꢀanꢀencasedꢀconverterꢀ
without a heatsink and with a typical heatsink are provided for
each output voltage.
Thermal Considerations: The maximum operating base-
plate temperature, TB,ꢀisꢀ100ꢀºC.ꢀAsꢀlongꢀasꢀtheꢀuser’sꢀthermalꢀ
system keeps TB <ꢀ 100ꢀ ºC,ꢀ theꢀ converterꢀ canꢀ deliverꢀ itsꢀ fullꢀ
rated power.
Aꢀpowerꢀderatingꢀcurveꢀcanꢀbeꢀcalculatedꢀforꢀanyꢀheatsinkꢀthatꢀisꢀ
attached to the base-plate of the converter. It is only necessary
toꢀdetermineꢀtheꢀthermalꢀresistance,ꢀRTHBA, of the chosen heatsink
between the base-plate and the ambient air for a given airflow
rate. This information is usually available from the heatsink
vendor. The following formula can the be used to determine the
V
in
Under-Voltageꢀ
LockoutꢀTurn-
OnꢀThreshold
ON/OFF
(negꢀlogic)
ON
OFF
ON
OFF
ON
9ms (typical
turnꢀonꢀtime)
V
out
200ms
(typical start-up
inhibitꢀperiod)
200ms
200ms
t
t0
t1
t2
Figure F: Startup Inhibit Period (turn-on time not to scale)
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 27
Technical
Specification
IQ48-HPC Family
PART ꢀUMBꢁRIꢀG SYSTꢁM
ORDꢁRIꢀG IꢀFORMATIOꢀ
Theꢀ partꢀ numberingꢀ systemꢀ forꢀ SynQor’sꢀ dc-dcꢀ convertersꢀ
follows the format shown in the example below.
The tables below show the valid model numbers and ordering
optionsꢀforꢀconvertersꢀinꢀthisꢀproductꢀfamily.ꢀꢀWhenꢀorderingꢀ
SynQorꢀconverters,ꢀpleaseꢀensureꢀthatꢀyouꢀuseꢀtheꢀcompleteꢀ
15ꢀcharacterꢀpartꢀnumberꢀconsistingꢀofꢀtheꢀ12ꢀcharacterꢀbaseꢀ
part number and the additional 3 characters for options.
Aꢀ“-G”ꢀsuffixꢀindicatesꢀtheꢀproductꢀisꢀ6/6ꢀRoHSꢀcompliant.
IQ 48 150 H P C 17 ꢀ R S - G
6/6ꢀRoHS
Options
(seeꢀOrderingꢀInformation)
Continuous
Input Voltage
Transient Input
Voltage
Output
Voltage
Maximum
Output Current
Model Number
OutputꢀCurrent
IQ48018HPC60xyz
IQ48033HPC60xyz
IQ48050HPC46xyz
IQ48120HPC21xyz
IQ48150HPC17xyz
IQ48240HPC10xyz
IQ48280HPC09xyz
IQ48400HPC6Dxyz
IQ48480HPC5Cxyz
34 - 75 V
34 - 75 V
34 - 75 V
34 - 75 V
34 - 75 V
34 - 75 V
34 - 75 V
34 - 75 V
34 - 75 V
100 V – 100 ms
100 V – 100 ms
100 V – 100 ms
100 V – 100 ms
100 V – 100 ms
100 V – 100 ms
100 V – 100 ms
100 V – 100 ms
100 V – 100 ms
1.8 V
3.3 V
5.0 V
12 V
15 V
24 V
28 V
40 V
48 V
60 A
60 A
46 A
21 A
17 A
10 A
9.0 A
6.3 A
5.2 A
ThermalꢀDesign
PerformanceꢀLevel
PackageꢀSize
OutputꢀVoltage
Input Voltage
ProductꢀFamily
The following options must be included in place of the x y z
spaces in the model numbers listed above.
Theꢀfirstꢀ12ꢀcharactersꢀcompriseꢀtheꢀbaseꢀpartꢀnumberꢀandꢀ
theꢀ lastꢀ 3ꢀ charactersꢀ indicateꢀ availableꢀ options.ꢀ ꢀ Theꢀ “-G”ꢀ
suffixꢀindicatesꢀ6/6ꢀRoHSꢀcompliance.
Options Description: x y z
Enable
Pin Length
Feature Set
Logic
Application ꢀotes
N - Negative
R - 0.180"
S - Standard
Aꢀvarietyꢀofꢀapplicationꢀnotesꢀandꢀtechnicalꢀwhiteꢀpapersꢀcanꢀ
be downloaded in pdf format from our website.
Not all combinations make valid part numbers, please contact
SynQor for availability.
RoHS Compliance:ꢀTheꢀEUꢀledꢀRoHSꢀ(RestrictionꢀofꢀHazardousꢀ
Substances)ꢀ Directiveꢀ bansꢀ theꢀ useꢀ ofꢀ Lead,ꢀ Cadmium,ꢀ
Hexavalentꢀ Chromium,ꢀ Mercury,ꢀ Polybrominatedꢀ Biphenylsꢀ
(PBB),ꢀandꢀPolybrominatedꢀDiphenylꢀEtherꢀ(PBDE)ꢀinꢀElectricalꢀ
andꢀ Electronicꢀ Equipment.ꢀ ꢀ Thisꢀ SynQorꢀ productꢀ isꢀ 6/6ꢀ RoHSꢀ
compliant.ꢀ ꢀ Forꢀ moreꢀ informationꢀ pleaseꢀ referꢀ toꢀ SynQor’sꢀ
RoHSꢀaddendumꢀavailableꢀatꢀourꢀRoHSꢀComplianceꢀ/ꢀLeadꢀFreeꢀ
PATꢁꢀTS
SynQorꢀholdsꢀtheꢀfollowingꢀpatents,ꢀoneꢀorꢀmoreꢀofꢀwhichꢀ
mightꢀapplyꢀtoꢀthisꢀproduct:
Initiative web page or e-mail us at rohs@synqor.com
.
ꢀ
ꢀ
ꢀ
ꢀ
5,999,417ꢀ
6,594,159ꢀ
6,927,987ꢀ
7,119,524ꢀ
6,222,742ꢀ
6,731,520ꢀ
7,050,309ꢀ
7,269,034ꢀ
6,545,890ꢀ
6,894,468ꢀ
7,072,190ꢀ
7,272,021ꢀ
6,577,109
6,896,526
7,085,146
7,272,023
Contact SynQor for further information:
Phone:ꢀ 978-849-0600
TollꢀFree:ꢀ 888-567-9596
Warranty
SynQorꢀoffersꢀaꢀtwoꢀ(2)ꢀyearꢀlimitedꢀwarranty.ꢀCompleteꢀwarrantyꢀ
information is listed on our website or is available upon request from
SynQor.
Fax:ꢀ
978-849-0602
E-mail:ꢀ
Web:ꢀ
Address:ꢀ 155ꢀSwansonꢀRoad
ꢀ
ꢀ
power@synqor.com
www.synqor.com
Informationꢀ furnishedꢀ byꢀ SynQorꢀ isꢀ believedꢀ toꢀ beꢀ accurateꢀ andꢀ
reliable.ꢀꢀHowever,ꢀnoꢀresponsibilityꢀisꢀassumedꢀbyꢀSynQorꢀforꢀitsꢀuse,ꢀ
nor for any infringements of patents or other rights of third parties
whichꢀmayꢀresultꢀfromꢀitsꢀuse.ꢀNoꢀlicenseꢀisꢀgrantedꢀbyꢀimplicationꢀorꢀ
otherwiseꢀunderꢀanyꢀpatentꢀorꢀpatentꢀrightsꢀofꢀSynQor.
ꢀ
ꢀ
Boxborough,ꢀMAꢀ01719
USA
Product # IQ48xxxHPCxx
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005062 Rev. A
09/25/08
Page 28
相关型号:
IQ48400HPC6DNRS-G
DC-DC Regulated Power Supply Module, 1 Output, 255W, Hybrid, ROHS COMPLIANT, HALF BRICK PACKAGE-8
SYNQOR
IQ48400HPD6DNRS-G
DC-DC Regulated Power Supply Module, 1 Output, 255W, Hybrid, ROHS COMPLIANT, HALF BRICK PACKAGE-8
SYNQOR
IQ48480HPC5CNRS-G
DC-DC Regulated Power Supply Module, 1 Output, 255W, Hybrid, ROHS COMPLIANT, HALF BRICK PACKAGE-8
SYNQOR
IQ48480HPD5DNRS-G
DC-DC Regulated Power Supply Module, 1 Output, 255W, Hybrid, ROHS COMPLIANT, HALF BRICK PACKAGE-8
SYNQOR
IQ48480QTC03NRS
DC-DC Regulated Power Supply Module, 1 Output, 144W, Hybrid, 1/4 BRICK PACKAGE-8
SYNQOR
©2020 ICPDF网 联系我们和版权申明