Technical  
Specification  
IQ90xxxQMXxx  
34-160V  
Continuous Input  
1.8-48V  
Outputs  
50W  
Max Power  
3000Vdc  
REINFORCED Isolation  
Quarter-brick  
DC-DC Converter  
The InQor quarter-brick converter series is composed  
of next-generation, board-mountable, isolated  
(REINFORCED), fixed switching frequency dc-dc  
converters that use synchronous rectification to achieve  
extremely high power conversion efficiency. Each module  
is supplied completely encased to provide protection  
from the harsh environments seen in many industrial and  
transportation applications.  
G
4
-
A
S
0
.
R
N
@
-
4
T
0
U
O
V
M
8
T
4
-
Q
8
.
0
1
2
1
N
I
Operational Features  
V
0
0
9
6
1
Q
-
I
4
3
• High efficiency, 92% at full rated load current  
• Delivers full power with minimal derating - no heatsink required  
• Operating input voltage range: 34-160V  
• Fixed frequency switching provides predictable EMI  
• No minimum load requirement  
ProtectionFeatures
Mechanical Features  
• Input under-voltage lockout  
• Output current limit and short circuit protection  
• Active back bias limit  
• Output over-voltage protection  
• Thermal shutdown  
• Industry standard quarter-brick pin-out configuration  
• Size: 1.536” x 2.386” (39.01 x 60.6)  
Total height: 0.500” (12.7mm)  
Total weight: 3.02oz (85.6g)  
Control Features  
CONTENTS  
• On/Off control referenced to input side  
• Remote sense for the output voltage  
• Output voltage trim range of -20%, +10%  
Page No.  
mily Electrical Characteristics (all output voltages) . . . . . . . . . . . . . . 2  
mily Figures (all output voltages). . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
ctrical Characteristics & Figures (1.8Vout) . . . . . . . . . . . . . . . . . . .4-5  
ctrical Characteristics & Figures (3.3Vout) . . . . . . . . . . . . . . . . . . .6-7  
ctrical Characteristics & Figures (5.0Vout) . . . . . . . . . . . . . . . . . . .8-9  
Electrical Characteristics & Figures (7.0Vout) . . . . . . . . . . . . . . . . . 10-11  
Electrical Characteristics & Figures (12.0Vout) . . . . . . . . . . . . . . . . 12-13  
Electrical Characteristics & Figures (15.0Vout) . . . . . . . . . . . . . . . . 14-15  
Electrical Characteristics & Figures (24.0Vout) . . . . . . . . . . . . . . . . 16-17  
Electrical Characteristics & Figures (30.0Vout) . . . . . . . . . . . . . . . . 18-19  
Electrical Characteristics & Figures (48.0Vout) . . . . . . . . . . . . . . . . 20-21  
Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-25  
Encased Mechanical Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27  
Encased Flanged Mechanical Drawing . . . . . . . . . . . . . . . . . . . . . . . . 28  
Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29  
Safety Features  
• 3000V, 100MΩ REINFORCED input-to-output isolation  
• UL 60950-1 2nd Ed. 2007  
• CAN/CSA-C22.2 No. 60950-1-07  
• EN60950-1 Ed. 2.0  
• CE Marked  
• RoHS compliant (see last page)  
P
m  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 1  
Technical  
Specification  
IQ90xxxQMXxx  
IQ90-QM Family Electrical Characteristics (all output voltages)  
Ta = 25°C, airflow rate = 300 LFM, Vin = 90Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
ABSOLUTE MAXIMUM RATINGS  
Input Voltage  
Min.  
Typ.  
Max. Units Notes & Conditions  
Non-Operating  
Operating  
160  
160  
V
V
Continuous  
Continuous  
Isolation Voltage  
Input to Output  
Input to Base-Plate  
Output to Base-Plate  
Operating Temperature  
Storage Temperature  
Voltage at ON/OFF input pin  
INPUT CHARACTERISTICS  
Operating Input Voltage Range  
Input Under-Voltage Lockout  
Turn-On Voltage Threshold  
Turn-Off Voltage Threshold  
Lockout Voltage Hysteresis  
Recommended External Input Capacitance  
Input Filter Component Values (L\C)  
DYNAMIC CHARACTERISTICS  
Turn-On Transient  
3000  
3000  
3000  
100  
125  
8
V dc  
V dc  
V dc  
°C  
°C  
V
-40  
-55  
-2  
Baseplate temperature  
34  
90  
160  
V
32.2  
29.3  
33.0  
30.0  
3.0  
33.8  
30.8  
V
V
V
100  
(4.7)\1.16  
µF  
Typical ESR 0.1-0.2Ω  
µH\µF Internal values; see Figure E  
Turn-On Time  
Start-Up Inhibit Time  
Output Voltage Overshoot  
ISOLATION CHARACTERISTICS  
Isolation Voltage (dielectric strength)  
Isolation Resistance  
10  
200  
0
ms  
ms  
%
Full load, Vout=90% nom.  
Figure F; See Note 2  
Maximum Output Capacitance  
180  
100  
250  
See Absolute Maximum Ratings  
500Vdc, Per IEC 60255-5  
See Note 1  
MΩ  
pF  
Isolation Capacitance (input to output)  
1000  
TEMPERATURE LIMITS FOR POWER DERATING CURVES  
Semiconductor Junction Temperature  
Board Temperature  
125  
125  
125  
100  
°C  
°C  
°C  
°C  
Package rated to 150°C  
UL rated max operating temp 130°C  
Transformer Temperature  
Maximum Baseplate Temperature, Tb  
FEATURE CHARACTERISTICS  
Switching Frequency  
250  
kHz  
V
ON/OFF Control  
Off-State Voltage  
On-State Voltage  
2.4  
-2  
8
0.8  
ON/OFF Control  
Pull-Up Voltage  
Pull-Up Resistance  
Over-Temperature Shutdown OTP Trip Point  
Over-Temperature Shutdown Restart Hysteresis  
RELIABILITY CHARACTERISTICS  
Calculated MTBF (Telcordia) TR-NWT-000332  
Calculated MTBF (MIL-217) MIL-HDBK-217F  
Field Demonstrated MTBF  
Application notes Figures A & B  
Average PCB Temperature  
Vin/6  
40  
125  
10  
15  
V
kΩ  
°C  
°C  
6
6
6
TBD  
TBD  
10 Hrs. 80% load, 200LFM, 40°C Ta  
10 Hrs. 80% load, 200LFM, 40°C Ta  
10 Hrs. See our website for details  
Note 1: Higher values of isolation capacitance can be added external to the module.  
Note 2: Maximum value is 400ms for DC current limit and short circuit fault conditions  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 2  
Technical  
Specification  
IQ90xxxQMXxx  
Family Figures (all output voltages)  
120  
100  
80  
60  
40  
20  
0
Nominal Vout  
Vin min  
Vin nom  
Vin max  
0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150  
Load Current (%)  
Common Figure 1: Typical startup waveform. Input voltage pre-applied, ON/  
OFF Pin on Ch 2.  
Common Figure 2: Output voltage vs. load current showing typical current limit  
curves and converter shutdown points.  
100,000.0  
100,000.0  
1.8 V  
3.3 V  
5 V  
7 V  
12 V  
15 V  
24 V  
30 V  
48 V  
10,000.0  
1,000.0  
100.0  
10,000.0  
1,000.0  
100.0  
10.0  
0
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15  
0
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15  
Increase in Vout (%)  
Increase in Vout (%)  
Common Figure 3: Trim graph for trim-up 1.8 to 12 V outputs.  
Common Figure 4: Trim graph for trim-up 15 to 48V outputs.  
10,000.0  
All voltages  
1,000.0  
100.0  
10.0  
0
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20  
Decrease in Vout (%)  
Common Figure 5: Trim graph for trim down.  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 3  
Input:34-160V  
Output:1.8V  
Current:25A  
Part No.:IQ90018QMx25  
Technical Specification  
IQ90018QMx25 Electrical Characteristics (1.8Vout)  
Ta = 25°C, airflow rate = 300 LFM, Vin = 90Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
2.1  
80  
3
A
mA  
mA  
V
mA  
A
Vin min; trim up; in current limit  
65  
2
0.04  
240  
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
Over Load  
Over Temperature  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
500V/ms; see Figure 6  
RMS  
Fast acting external fuse recommended  
10  
1.782  
1.8  
1.818  
V
±0.1  
±0.1  
±0.3  
±0.3  
27  
%
%
mV  
V
-27  
1.755  
1.845  
Over sample, line, load, temperature & life  
20MHz bandwidth; see Note 1  
Full load  
Full load  
Subject to thermal derating  
Output voltage 10% Low  
0
100  
25  
200  
50  
25  
mV  
mV  
A
RMS  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1A/µs)  
Settling Time  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
0
27.5  
30.0  
0.8  
4.5  
10  
32.5  
A
V
A
mA  
µF  
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
10,000  
100  
400  
mV  
µs  
%
%
V
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Across Pins 8&4; Common Figures 3-5; see Note 2  
Across Pins 8&4  
-20  
2.1  
10  
10  
2.3  
2.2  
Over full temp range  
100% Load  
50% Load  
84  
82  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
Note 1: Output is terminated with 1µF ceramic and 22µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: Trim-up range is limited below 10% at low line and full load. Contact SynQor applications support for more detail (email: support@synqor.com)  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 4  
Input:34-160V  
Output:1.8V  
Current:25A  
Part No.:IQ90018QMx25  
Technical Specification  
100  
95  
90  
85  
80  
75  
70  
65  
60  
16  
12  
8
4
34 Vin  
90 Vin  
160 Vin  
34 Vin  
90 Vin  
160 Vin  
0
0
5
10  
15  
20  
25  
0
5
10  
15  
20  
25  
Load Current (A)  
Load Current (A)  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25°C.  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
30  
25  
20  
15  
30  
25  
20  
15  
10  
10  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
5
0
5
0
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
25  
40  
55  
Ambient Air Temperature (°C)  
70  
85  
25  
40  
55  
Ambient Air Temperature (°C)  
70  
85  
Figure 3: Encased converter (without heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating  
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 5: Output response to load current step for QTC version of product (50%-  
75%-50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF  
ceramic cap. Ch 1: Vout, Ch 2: Iout.  
Figure 6: Output voltage response to step-change in input voltage (nominal to  
maximum), at full load current. Load cap: 15µF tantalum capacitor and 1uF  
ceramic cap. Ch 1: Vout, Ch 2: Vin.  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 5  
Input:34-160V  
Output:3.3V  
Current:15A  
Part No.:IQ90033QMx15  
Technical Specification  
IQ90033QMx15 Electrical Characteristics (3.3Vout)  
Ta = 25°C, airflow rate = 300 LFM, Vin = 90Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
2.2  
110  
4
A
mA  
mA  
V
mA  
A
Vin min; trim up; in current limit  
90  
3
0.06  
300  
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
Over Load  
Over Temperature  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
500V/ms; see Figure 6  
RMS  
Fast acting external fuse recommended  
10  
3.267  
3.3  
3.333  
V
±0.1  
±0.1  
±0.3  
±0.3  
50  
%
%
mV  
V
-50  
3.218  
3.383  
Over sample, line, load, temperature & life  
20MHz bandwidth; see Note 1  
Full load  
Full load  
Subject to thermal derating  
Output voltage 10% Low  
0
100  
27  
200  
50  
15  
mV  
mV  
A
RMS  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1A/µs)  
Settling Time  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
0
16.5  
18.0  
1.8  
2
19.5  
A
V
A
mA  
µF  
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
10  
10,000  
140  
400  
mV  
µs  
%
%
V
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Across Pins 8&4; Common Figures 3-5  
Across Pins 8&4  
-20  
3.9  
10  
10  
4.2  
4.0  
Over full temp range  
100% Load  
50% Load  
87  
83  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
Note 1: Output is terminated with 1µF ceramic and 22µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: Trim-up range is limited below 10% at low line and full load. Contact SynQor applications support for more detail (email: support@synqor.com)  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 6  
Input:34-160V  
Output:3.3V  
Current:15A  
Part No.:IQ90033QMx15  
Technical Specification  
100  
95  
90  
85  
80  
75  
70  
65  
60  
12  
9
6
3
34 Vin  
90 Vin  
160 Vin  
34 Vin  
90 Vin  
160 Vin  
0
0
5
10  
15  
0
5
10  
15  
Load Current (A)  
Load Current (A)  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25°C.  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
16  
14  
12  
10  
8
16  
14  
12  
10  
8
6
6
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
4
4
300 LFM (1.5 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
200 LFM (1.0 m/s)  
2
2
100 LFM (0.5 m/s)  
100 LFM (0.5 m/s)  
0
0
25  
40  
55  
70  
85  
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating  
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 3: Encased converter (without heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 5: Output response to load current step for QTC version of product (50%-  
75%-50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF  
ceramic cap. Ch 1: Vout, Ch 2: Iout.  
Figure 6: Output voltage response to step-change in input voltage (nominal to  
maximum), at full load current. Load cap: 15µF tantalum capacitor and 1uF  
ceramic cap. Ch 1: Vout, Ch 2: Vin.  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 7  
Input:34-160V  
Output:5V  
Current:10A  
Part No.:IQ90050QMx10  
Technical Specification  
IQ90050QMx10 Electrical Characteristics (5.0Vout)  
Ta = 25°C, airflow rate = 300 LFM, Vin = 90Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
2.2  
80  
3
A
mA  
mA  
V
mA  
A
Vin min; trim up; in current limit  
60  
2
0.1  
350  
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
Over Load  
Over Temperature  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
500V/ms; see Figure 6  
RMS  
Fast acting external fuse recommended  
10  
4.95  
5.000  
5.05  
V
±0.1  
±0.1  
±0.3  
±0.3  
75  
%
%
mV  
V
-75  
4.875  
5.125  
Over sample, line, load, temperature & life  
20MHz bandwidth; see Note 1  
Full load  
Full load  
Subject to thermal derating  
Output voltage 10% Low  
0
75  
20  
150  
40  
10  
mV  
mV  
A
RMS  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1A/µs)  
Settling Time  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
0
11.0  
12.0  
0.9  
0.9  
10  
13.0  
A
V
A
mA  
µF  
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
8,000  
250  
400  
mV  
µs  
%
%
V
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Across Pins 8&4; Common Figures 3-5; see Note 2  
Across Pins 8&4  
-20  
5.9  
10  
10  
6.4  
6.1  
Over full temp range  
100% Load  
50% Load  
89  
84  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
Note 1: Output is terminated with 1µF ceramic and 22µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: Trim-up range is limited below 10% at low line and full load. Contact SynQor applications support for more detail (email: support@synqor.com)  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 8  
Input:34-160V  
Output:5V  
Current:10A  
Part No.:IQ90050QMx10  
Technical Specification  
100  
95  
90  
85  
80  
75  
70  
65  
60  
10  
8
6
4
34 Vin  
90 Vin  
160 Vin  
34 Vin  
90 Vin  
160 Vin  
2
0
0
5
10  
0
5
10  
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
12  
10  
8
12  
10  
8
6
6
4
4
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
2
2
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
0
0
25  
40  
55  
70  
85  
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Encased converter (without heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25°C.  
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating  
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 5: Output response to load current step for QTC version of product (50%-  
75%-50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF  
ceramic cap. Ch 1: Vout, Ch 2: Iout.  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 9  
Input:34-160V  
Output:7V  
Current:7A  
Part No.:IQ90070QMx07  
Technical Specification  
IQ90070QMx07 Electrical Characteristics (7.0Vout)  
Ta = 25°C, airflow rate = 300 LFM, Vin = 90Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
2.1  
100  
3
A
mA  
mA  
V
mA  
A
Vin min; trim up; in current limit  
80  
2
0.12  
300  
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
Over Load  
Over Temperature  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
500V/ms; see Figure 6  
RMS  
Fast acting external fuse recommended  
10  
6.93  
7
7.07  
V
±0.1  
±0.1  
±0.3  
±0.3  
105  
%
%
mV  
V
-105  
6.825  
7.175  
Over sample, line, load, temperature & life  
20MHz bandwidth; see Note 1  
Full load  
Full load  
Subject to thermal derating  
Output voltage 10% Low  
0
80  
20  
160  
40  
7
mV  
mV  
A
RMS  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1A/µs)  
Settling Time  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
0
7.7  
8.4  
0.9  
0.8  
10  
9.1  
A
V
A
mA  
µF  
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
8,000  
200  
400  
mV  
µs  
%
%
V
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Across Pins 8&4; Common Figures 3-5; see Note 2  
Across Pins 8&4  
-20  
8.2  
10  
10  
8.9  
8.5  
Over full temp range  
100% Load  
50% Load  
89  
83  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
Note 1: Output is terminated with 1µF ceramic and 22µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: Trim-up range is limited below 10% at low line and full load. Contact SynQor applications support for more detail (email: support@synqor.com)  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 10  
Input:34-160V  
Output:7V  
Current:7A  
Part No.:IQ90070QMx07  
Technical Specification  
100  
95  
90  
85  
80  
75  
70  
65  
60  
10  
8
6
4
34 Vin  
90 Vin  
160 Vin  
34 Vin  
90 Vin  
160 Vin  
2
0
0
3
6
0
3
6
Load Current (A)  
Load Current (A)  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25°C.  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
10  
8
10  
8
6
6
4
4
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
300 LFM (1.5 m/s)  
2
2
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
0
0
25  
40  
55  
70  
85  
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Encased converter (without heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating  
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 5: Output response to load current step for QTC version of product (50%-  
75%-50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF  
ceramic cap. Ch 1: Vout, Ch 2: Iout.  
Figure 6: Output voltage response to step-change in input voltage (nominal to  
maximum), at full load current. Load cap: 15µF tantalum capacitor and 1uF  
ceramic cap. Ch 1: Vout, Ch 2: Vin.  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 11  
Input:34-160V  
Output:12V  
Current:4A  
Part No.:IQ90120QMx04  
Technical Specification  
IQ90120QMx04 Electrical Characteristics (12.0Vout)  
Ta = 25°C, airflow rate = 300 LFM, Vin = 90Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
2.0  
80  
4
A
mA  
mA  
V
mA  
A
Vin min; trim up; in current limit  
60  
2
0.25  
315  
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
Over Load  
Over Temperature  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
500V/ms; see Figure 6  
RMS  
Fast acting external fuse recommended  
10  
11.88  
12.000  
12.12  
V
±0.1  
±0.1  
±0.3  
±0.3  
180  
%
%
mV  
V
-180  
11.700  
12.300  
Over sample, line, load, temperature & life  
20MHz bandwidth; see Note 1  
Full load  
Full load  
Subject to thermal derating  
Output voltage 10% Low  
0
80  
20  
160  
40  
4
mV  
mV  
A
RMS  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1A/µs)  
Settling Time  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
0
4.4  
4.8  
4.9  
0.4  
10  
5.2  
A
V
A
mA  
µF  
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
1,500  
400  
400  
mV  
µs  
%
%
V
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Across Pins 8&4; Common Figures 3-5; see Note 2  
Across Pins 8&4  
-20  
10  
10  
15.2  
14.0  
14.6  
Over full temp range  
100% Load  
50% Load  
92  
88  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
Note 1: Output is terminated with 1µF ceramic and 22µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: Trim-up range is limited below 10% at low line and full load. Contact SynQor applications support for more detail (email: support@synqor.com)  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 12  
Input:34-160V  
Output:12V  
Current:4A  
Part No.:IQ90120QMx04  
Technical Specification  
100  
95  
90  
85  
80  
75  
70  
65  
60  
9
6
3
0
34 Vin  
90 Vin  
160 Vin  
34 Vin  
90 Vin  
160 Vin  
0
1
2
3
4
0
1
2
3
4
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
5
4
3
5
4
3
2
1
0
2
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
300 LFM (1.5 m/s)  
1
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
0
25  
40  
55  
70  
85  
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Encased converter (without heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25°C.  
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating  
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 5: Output response to load current step for QTC version of product (50%-  
75%-50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF  
ceramic cap. Ch 1: Vout, Ch 2: Iout.  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 13  
Input:34-160V  
Output:15V  
Current:3.3A  
Part No.:IQ90150QMx04  
Technical Specification  
IQ90150QMx04 Electrical Characteristics (15.0Vout)  
Ta = 25°C, airflow rate = 300 LFM, Vin = 90Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
2.1  
80  
3
A
mA  
mA  
V
mA  
A
Vin min; trim up; in current limit  
60  
2
0.3  
350  
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
Over Load  
Over Temperature  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
500V/ms; see Figure 6  
RMS  
Fast acting external fuse recommended  
10  
14.85  
15.000  
15.15  
V
±0.1  
±0.1  
±0.3  
±0.3  
225  
%
%
mV  
V
-225  
14.625  
15.375  
Over sample, line, load, temperature & life  
20MHz bandwidth; see Note 1  
Full load  
Full load  
Subject to thermal derating  
Output voltage 10% Low  
0
100  
20  
200  
40  
3.3  
4.3  
mV  
mV  
A
RMS  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1A/µs)  
Settling Time  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
0
3.6  
4.0  
4.9  
0.24  
10  
A
V
A
mA  
µF  
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
1,000  
450  
400  
mV  
µs  
%
%
V
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Across Pins 8&4; Common Figures 3-5; see Note 2  
Across Pins 8&4  
-20  
10  
10  
19.1  
17.6  
18.3  
Over full temp range  
100% Load  
91  
86  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
50% Load  
Note 1: Output is terminated with 1µF ceramic and 22µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and  
noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 2: Trim-up range is limited below 10% at low line and full load. Contact SynQor applications support for more detail (email: support@synqor.com)  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 14  
Input:34-160V  
Output:15V  
Current:3.3A  
Part No.:IQ90150QMx04  
Technical Specification  
100  
95  
90  
85  
80  
75  
70  
65  
60  
9
6
3
0
34 Vin  
90 Vin  
160 Vin  
34 Vin  
90 Vin  
160 Vin  
0
1
2
3
0
1
2
3
Load Current (A)  
Load Current (A)  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25°C.  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
4
3
2
4
3
2
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
1
1
300 LFM (1.5 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
0
0
25  
40  
55  
70  
85  
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Encased converter (without heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating  
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 5: Output response to load current step for QTC version of product (50%-  
75%-50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF  
ceramic cap. Ch 1: Vout, Ch 2: Iout.  
Figure 6: Output voltage response to step-change in input voltage (nominal to  
maximum), at full load current. Load cap: 15µF tantalum capacitor and 1uF  
ceramic cap. Ch 1: Vout, Ch 2: Vin.  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 15  
Input:34-160V  
Output:24V  
Current:2A  
Part No.:IQ90240QMx02  
Technical Specification  
IQ90240QMx02 Electrical Characteristics (24.0Vout)  
Ta = 25°C, airflow rate = 300 LFM, Vin = 90Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
2.1  
110  
4
A
mA  
mA  
V
mA  
A
Vin min; trim up; in current limit  
90  
2
0.48  
350  
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
Over Load  
Over Temperature  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
500V/ms; see Figure 6  
RMS  
Fast acting external fuse recommended  
10  
23.76  
24.00  
24.24  
V
±0.1  
±0.1  
±0.3  
±0.3  
360  
%
%
mV  
V
-360  
23.400  
24.600  
Over sample, line, load, temperature & life  
20MHz bandwidth; see Note 1  
Full load  
Full load  
Subject to thermal derating  
Output voltage 10% Low  
0
60  
18  
120  
40  
2
mV  
mV  
A
RMS  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1A/µs)  
Settling Time  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
0
2.2  
2.4  
10  
0.185  
10  
2.6  
A
V
A
mA  
µF  
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
400  
600  
400  
mV  
µs  
%
%
V
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Across Pins 8&4; Common Figures 3-5  
Across Pins 8&4  
-20  
10  
10  
30.5  
28.1  
29.3  
Over full temp range  
100% Load  
50% Load  
88  
82  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications  
support (e-mail: support@synqor.com)  
Note 2: Trim-up range is limited below 10% at low line and full load. Contact SynQor applications support for more detail (email: support@synqor.com)  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 16  
Input:34-160V  
Output:24V  
Current:2A  
Part No.:IQ90240QMx02  
Technical Specification  
100  
95  
90  
85  
80  
75  
70  
65  
60  
100  
95  
90  
85  
80  
75  
70  
65  
60  
34 Vin  
90 Vin  
160 Vin  
34 Vin  
90 Vin  
160 Vin  
0
1
2
0
1
2
Load Current (A)  
Load Current (A)  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25°C.  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
3
2
3
2
1
1
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
0
0
25  
40  
55  
70  
85  
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Encased converter (without heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating  
vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air  
flows across the converter from input to output (nominal input voltage).  
Figure 6: Output voltage response to step-change in input voltage (nominal to  
maximum), at full load current. Load cap: 1uF ceramic cap. Ch 1: Vout, Ch 2:  
Vin.  
Figure 5: Output response to load current step for QTC version of product (50%-  
75%-50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF  
ceramic cap. Ch 1: Vout, Ch 2: Iout.  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 17  
Input:34-160V  
Output:30V  
Current:1.6A  
Part No.:IQ90300QMx02  
Technical Specification  
IQ90300QMx02 Electrical Characteristics (30.0Vout)  
Ta = 25°C, airflow rate = 300 LFM, Vin = 90Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
2.1  
130  
4
A
mA  
mA  
V
mA  
A
Vin min; trim up; in current limit  
100  
2
0.6  
375  
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
Over Load  
Over Temperature  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
500V/ms; see Figure 6  
RMS  
Fast acting external fuse recommended  
10  
29.7  
30.000  
30.3  
V
±0.1  
±0.1  
±0.3  
±0.3  
450  
%
%
mV  
V
-450  
29.250  
30.750  
Over sample, line, load, temperature & life  
20MHz bandwidth; see Note 1  
Full load  
Full load  
Subject to thermal derating  
Output voltage 10% Low  
0
120  
20  
240  
40  
1.6  
2.1  
mV  
mV  
A
RMS  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1A/µs)  
Settling Time  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
0
1.8  
1.9  
12  
0.17  
10  
A
V
A
mA  
µF  
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
250  
960  
500  
mV  
µs  
%
%
V
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Across Pins 8&4; Common Figures 3-5  
Across Pins 8&4  
-20  
10  
10  
38.1  
35.1  
36.6  
Over full temp range  
100% Load  
50% Load  
88  
83  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications  
support (e-mail: support@synqor.com)  
Note 2: Trim-up range is limited below 10% at low line and full load. Contact SynQor applications support for more detail (email: support@synqor.com)  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 18  
Input:34-160V  
Output:30V  
Current:1.6A  
Part No.:IQ90300QMx02  
Technical Specification  
100  
95  
90  
85  
80  
75  
70  
65  
60  
12  
9
6
3
34 Vin  
90 Vin  
160 Vin  
34 Vin  
90 Vin  
160 Vin  
0
0
1
0
1
Load Current (A)  
Load Current (A)  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25°C.  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
2.0  
1.5  
1.0  
2.0  
1.5  
1.0  
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
0.5  
0.5  
300 LFM (1.5 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
0.0  
0.0  
25  
40  
55  
70  
85  
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Encased converter (without heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows  
across the converter from input to output (nominal input voltage).  
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows  
across the converter from input to output (nominal input voltage).  
Figure 6: Output voltage response to step-change in input voltage (nominal to  
maximum), at full load current. Load cap: 1uF ceramic cap. Ch 1: Vout, Ch 2:  
Vin.  
Figure 5: Output response to load current step for QTC version of product (50%-  
75%-50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF  
ceramic cap. Ch 1: Vout, Ch 2: Iout.  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 19  
Input:34-160V  
Output:48V  
Current:1A  
Part No.:IQ90480QMx01  
Technical Specification  
IQ90480QMx01 Electrical Characteristics (48.0Vout)  
Ta = 25°C, airflow rate = 300 LFM, Vin = 90Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C baseplate temperature  
with appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
INPUT CHARACTERISTICS  
Maximum Input Current  
No-Load Input Current  
2.1  
110  
3
A
mA  
mA  
V
mA  
A
Vin min; trim up; in current limit  
90  
2
1.1  
350  
Disabled Input Current  
Response to Input Transient  
Input Terminal Ripple Current  
Recommended Input Fuse  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
Over Load  
Over Temperature  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
500V/ms; see Figure 6  
RMS  
Fast acting external fuse recommended  
10  
47.52  
48.00  
48.48  
V
±0.1  
±0.1  
±0.3  
±0.3  
720  
%
%
mV  
V
-720  
46.800  
49.200  
Over sample, line, load, temperature & life  
20MHz bandwidth; see Note 1  
Full load  
Full load  
Subject to thermal derating  
Output voltage 10% Low  
0
120  
35  
240  
70  
1
mV  
mV  
A
RMS  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Enabled  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1A/µs)  
Settling Time  
Output Voltage Trim Range  
Output Voltage Remote Sense Range  
Output Over-Voltage Protection  
EFFICIENCY  
0
1.1  
1.2  
20  
0.08  
5
1.3  
A
V
A
mA  
µF  
Negative current drawn from output  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
100  
1500  
500  
mV  
µs  
%
%
V
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Across Pins 8&4; Common Figures 3-5  
Across Pins 8&4  
-20  
10  
10  
61.0  
56.2  
58.6  
Over full temp range  
100% Load  
50% Load  
88  
82  
%
%
See Figure 1 for efficiency curve  
See Figure 1 for efficiency curve  
Note 1: Output is terminated with 1 µF ceramic capacitor. For applications requiring reduced output voltage ripple and noise, consult SynQor applications  
support (e-mail: support@synqor.com)  
Note 2: Trim-up range is limited below 10% at low line and full load. Contact SynQor applications support for more detail (email: support@synqor.com)  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 20  
Input:34-160V  
Output:48V  
Current:1A  
Part No.:IQ90480QMx01  
Technical Specification  
100  
95  
90  
85  
80  
75  
70  
65  
60  
12  
9
6
3
34 Vin  
90 Vin  
160 Vin  
34 Vin  
90 Vin  
160 Vin  
0
0.0  
0.5  
1.0  
0.0  
0.5  
1.0  
Load Current (A)  
Load Current (A)  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25°C.  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25°C.  
1.2  
1.0  
0.8  
0.6  
1.2  
1.0  
0.8  
0.6  
0.4  
0.4  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
0.2  
0.2  
200 LFM (1.0 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
100 LFM (0.5 m/s)  
0.0  
0.0  
25  
40  
55  
70  
85  
25  
40  
55  
70  
85  
Ambient Air Temperature (°C)  
Ambient Air Temperature (°C)  
Figure 3: Encased converter (without heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows  
across the converter from input to output (nominal input voltage).  
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs.  
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows  
across the converter from input to output (nominal input voltage).  
Figure 5: Output response to load current step for QTC version of product (50%-  
75%-50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF tantalum cap and 1µF  
ceramic cap. Ch 1: Vout, Ch 2: Iout.  
Figure 6: Output voltage response to step-change in input voltage (nominal to  
maximum), at full load current. Load cap: 1uF ceramic cap. Ch 1: Vout, Ch 2:  
Vin.  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 21  
Technical  
Specification  
IQ90xxxQMXxx  
BASIC OPERATION AND FEATURES  
CONTROL FEATURES  
This converter series uses a two-stage power conversion  
topology. The first stage is a buck-converter that keeps the  
output voltage constant over variations in line, load, and  
temperature. The second stage uses a transformer to provide  
the functions of input/output isolation and voltage step-up or  
step-down to achieve the output voltage required.  
REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2, permits  
the user to control when the converter is on or off. This input  
is referenced to the return terminal of the input bus, Vin(-).  
The ON/OFF signal is active low (meaning that a low turns the  
converter on). Figure A details four possible circuits for driving  
the ON/OFF pin. Figure B is a detailed look of the internal ON/  
OFF circuitry.  
Both the first stage and the second stage switch at a fixed  
frequency for predictable EMI performance. Rectification of  
the transformer’s output is accomplished with synchronous  
rectifiers. These devices, which are MOSFETs with a very low  
on-state resistance, dissipate far less energy than Schottky  
diodes. This is the primary reason that the converter has such  
high efficiency, even at very low output voltages and very high  
output currents.  
REMOTE SENSE(+) (Pins 7 and 5): The SENSE(+) inputs  
correct for voltage drops along the conductors that connect the  
converter’s output pins to the load.  
Pin 7 should be connected to Vout(+) and Pin 5 should be  
connected to Vout(-) at the point on the board where regulation  
is desired. A remote connection at the load can adjust for a  
voltage drop only as large as that specified in this datasheet,  
that is  
These converters are offered totally encased to withstand harsh  
environments and thermally demanding applications. Dissipation  
throughout the converter is so low that it does not require a  
heatsink for operation in many applications; however, adding  
a heatsink provides improved thermal derating performance in  
extreme situations.  
[Vout(+) - Vout(-)] [Vsense(+) - Vsense(-)] <  
Sense Range % x Vout  
Pins 7 and 5 must be connected for proper regulation of  
the output voltage. If these connections are not made, the  
converter will deliver an output voltage that is slightly higher  
than its specified value.  
This series of converters use the industry standard footprint and  
pin-out configuration.  
Note: the output over-voltage protection circuit senses the  
voltage across the output (pins 8 and 4) to determine when  
it should trigger, not the voltage across the converter’s sense  
leads (pins 7 and 5). Therefore, the resistive drop on the board  
should be small enough so that output OVP does not trigger,  
even during load transients.  
ON/OFF  
ON/OFF  
Vin(_)  
Vin(_)  
Remote Enable Circuit  
Negative Logic  
(Permanently Enabled)  
5V  
5V  
ON/OFF  
50k  
TTL/  
CMOS  
ON/OFF  
Vin(_)  
ON/OFF  
Vin(_)  
50k  
TTL  
100pF  
Vin(_)  
Open Collector Enable Circuit  
Direct Logic Drive  
Figure A: Various circuits for driving the ON/OFF pin.  
Figure B: Internal ON/OFF pin circuitry  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 22  
Technical  
Specification  
IQ90xxxQMXxx  
OUTPUT VOLTAGE TRIM (Pin 6): The TRIM input permits the  
user to adjust the output voltage across the sense leads up or  
down according to the trim range specifications.  
PROTECTION FEATURES  
Input Under-Voltage Lockout: The converter is designed  
to turn off when the input voltage is too low, helping avoid an  
input system instability problem, described in more detail in  
the application note titled “Input System Instability” on our  
website. The lockout circuitry is a comparator with dc hysteresis.  
When the input voltage is rising, it must exceed the typical Turn-  
On Voltage Threshold value (listed on the specifications page)  
before the converter will turn on. Once the converter is on,  
the input voltage must fall below the typical Turn-Off Voltage  
Threshold value before the converter will turn off.  
To decrease the output voltage, the user should connect a  
resistor between Pin 6 and Pin 5 (SENSE(-) input). For a desired  
decrease of the nominal output voltage, the value of the resistor  
should be  
511  
R
=
- 10.22 (kW)  
trim-down  
(D%)  
where  
Vnominal – Vdesired  
Vnominal  
Output Current Limit: The maximum current limit remains  
constant as the output voltage drops. However, once the  
impedance of the load across the output is small enough to make  
the output voltage drop below the specified Output DC Current-  
Limit Shutdown Voltage, the converter turns off.  
=
x 100%  
D%  
To increase the output voltage, the user should connect a  
resistor between Pin 6 and Pin 7 (SENSE(+) input). For a desired  
increase of the nominal output voltage, the value of the resistor  
should be  
The converter then enters a “hiccup mode” where it repeatedly  
turns on and off at a 5 Hz (nominal) frequency with a 5% duty  
cycle until the short circuit condition is removed. This prevents  
excessive heating of the converter or the load board.  
5.11VOUT (100+D%)  
x
511  
_
R
_
=
(kW)  
trim-up  
10.22  
)
(
1.225D%  
D%  
Output Over-Voltage Limit: If the voltage across the output  
pins exceeds the Output Over-Voltage Protection threshold, the  
converter will immediately stop switching. This prevents damage  
to the load circuit due to 1) excessive series resistance in output  
current path from converter output pins to sense point, 2) a  
release of a short-circuit condition, or 3) a release of a current  
limit condition. Load capacitance determines exactly how high  
the output voltage will rise in response to these conditions. After  
200 ms the converter will automatically restart.  
where  
V
= Nominal Output Voltage  
out  
Trim graphs show the relationship between the trim resistor  
value and Rtrim-up and Rtrim-down, showing the total range the  
output voltage can be trimmed up or down.  
Note: the TRIM feature does not affect the voltage at which the  
output over-voltage protection circuit is triggered. Trimming the  
output voltage too high may cause the over-voltage protection  
circuit to engage, particularly during transients.  
Over-Temperature Shutdown: A temperature sensor on  
the converter senses the average temperature of the module.  
The thermal shutdown circuit is designed to turn the converter  
off when the temperature at the sensed location reaches the  
Over-Temperature Shutdown value. It will allow the converter  
to turn on again when the temperature of the sensed location  
falls by the amount of the Over-Temperature Shutdown Restart  
Hysteresis value.  
It is not necessary for the user to add capacitance at the Trim  
pin. The node is internally bypassed to eliminate noise.  
Total DC Variation of V  
specifications, the maximum variation of the dc value of V  
: For the converter to meet its full  
OUT  
,
OUT  
due to both trimming and remote load voltage drops, should not  
be greater than that specified for the output voltage trim range.  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 23  
Technical  
Specification  
IQ90xxxQMXxx  
APPLICATION CONSIDERATIONS  
Input System Instability: This condition can occur because Application Circuits: Figure C provides a typical circuit diagram  
any dc-dc converter appears incrementally as a negative which details the input filtering and voltage trimming.  
resistance load. A detailed application note titled “Input System  
Instability” is available on the SynQor website which provides  
an understanding of why this instability arises, and shows the  
preferred solution for correcting it.  
Vout(+)  
Vin(+)  
Electrolytic  
Capacitor  
Vsense(+)  
External  
Input  
Filter  
Rtrim-up  
Vin  
Trim  
or  
ON/OFF  
Vin(_)  
Cload  
Rtrim-down  
Iload  
Vsense(_)  
Vout(_)  
Figure C: Typical application circuit (negative logic unit, permanently enabled).  
Input Filtering and External Capacitance: Figure D provides The recommended external input capacitance is specified in the  
a diagram showing the internal input filter components. This filter Input Characteristics section on the Electrical Characteristics  
dramatically reduces input terminal ripple current, which otherwise page. More detailed information is available in the application note  
could exceed the rating of an external electrolytic input capacitor. titled “EMI Characteristics” on the SynQor website.  
L
Vin(+)  
C
Vin(_)  
Figure D: Internal Input Filter Diagram (component values listed on the specifications page).  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 24  
Technical  
Specification  
IQ90xxxQMXxx  
Startup Inhibit Period: The Startup Inhibit Period ensures that When the ON/OFF pin goes high after t2, the Startup Inhibit  
the converter will remain off for approximately 200 ms when it is Period has elapsed, and the output turns on within the typical  
shut down for any reason. When an output short is present, this Turn-On Time.  
generates a 5 Hz “hiccup mode,” which prevents the converter  
from overheating. In all, there are seven ways that the converter  
can be shut down, initiating a Startup Inhibit Period:  
Thermal Considerations: The maximum operating base-plate  
temperature, TB, is 100 ºC. As long as the user’s thermal system  
keeps TB < 100 ºC, the converter can deliver its full rated power.  
•ꢀ InputꢀUnder-VoltageꢀLockout  
•ꢀ InputꢀOver-VoltageꢀLockout  
•ꢀ OutputꢀOver-VoltageꢀProtection  
•ꢀ OverꢀTemperatureꢀShutdown  
•ꢀ CurrentꢀLimit  
A power derating curve can be calculated for any heatsink that is  
attached to the base-plate of the converter. It is only necessary  
to determine the thermal resistance, RTHBA, of the chosen heatsink  
between the base-plate and the ambient air for a given airflow  
rate. This information is usually available from the heatsink  
vendor. The following formula can the be used to determine the  
maximum power the converter can dissipate for a given thermal  
condition if its base-plate is to be no higher than 100 ºC.  
•ꢀ ShortꢀCircuitꢀProtection  
•ꢀ TurnedꢀoffꢀbyꢀtheꢀON/OFFꢀinput  
Figure E shows three turn-on scenarios, where a Startup Inhibit  
Period is initiated at t0, t1, and t2:  
100 ºC - TA  
Pmax  
=
diss  
RTH  
BA  
Before time t0, when the input voltage is below the UVL threshold,  
the unit is disabled by the Input Under-Voltage Lockout feature.  
When the input voltage rises above the UVL threshold, the Input  
Under-Voltage Lockout is released, and a Startup Inhibit Period is  
initiated. At the end of this delay, the ON/OFF pin is evaluated,  
and since it is active, the unit turns on.  
This value of power dissipation can then be used in conjunction  
with the data shown in Figure 2 to determine the maximum load  
current (and power) that the converter can deliver in the given  
thermal condition.  
For convenience, power derating curves for an encased converter  
without a heatsink and with a typical heatsink are provided for  
each output voltage.  
At time t1, the unit is disabled by the ON/OFF pin, and it cannot  
be enabled again until the Startup Inhibit Period has elapsed.  
V
in  
Under-Voltage  
Lockout Turn-  
On Threshold  
ON/OFF  
(neg logic)  
ON  
OFF  
ON  
OFF  
ON  
9ms (typical  
turn on time)  
V
out  
200ms  
(typical start-up  
inhibit period)  
200ms  
200ms  
t
t0  
t1  
t2  
Figure E: Startup Inhibit Period (turn-on time not to scale)  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 25  
Technical  
Specification  
IQ90xxxQMXxx  
IQ90-QT Standards and Qualifications  
Parameter  
Notes & Conditions  
STANDARDS COMPLIANCE  
UL 60950-1 2nd Ed. 2007  
CAN/CSA-C22.2 No. 60950-1-07  
EN60950-1 Ed. 2.0  
Reinforced Insulation  
CE Marked  
2006/95/EC Low Voltage Directive  
IEC 61000-4-2  
ESD test, 8 kV - NP, 15 kV air - NP (Normal Performance)  
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new  
releases or download from the SynQor website.  
Parameter  
QUALIFICATION TESTING  
Life Test  
# Units Test Conditions  
32  
5
5
95% rated Vin and load, units at derating point, 1000 hours  
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis  
100g minimum, 2 drops in x, y and z axis  
Vibration  
Mechanical Shock  
Temperature Cycling  
Power/Thermal Cycling  
Design Marginality  
Humidity  
10  
5
5
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles  
Toperating = min to max, Vin = min to max, full load, 100 cycles  
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load  
85 °C, 85% RH, 1000 hours, continuous Vin applied except 5 min/day  
5
Solderability  
15 pins MIL-STD-883, method 2003  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 26  
Technical  
Specification  
IQ90xxxQMXxx  
IQ90-QT Family Mechanical Drawing  
1.536 ±0.020 (39.01 ±0.5)  
1. 030 (26.16)  
0.600 (15.24)  
0.450 (11.43)  
0.300 (7.62)  
0.150 (3.81)  
0.253±0.020 (6.4±0.5)  
0.500±0.025  
(12.7±0.63)  
Overall Height  
8 7 6 5 4  
0.263±0.020  
(6.68±0.5)  
2.386  
± 0.020  
(60.6± 0.5)  
0.18±0.010  
(4.57±0.25)  
Top View  
2.00  
(50.8)  
Side View  
1.86  
(47.2)  
1
3
2
M3 Threaded Inserts  
4 Places  
See Notes  
(11.89±0.5)  
0.468±0.020  
0.300 (7.62)  
0.600 (15.24)  
0.183±.020  
(4.65)±0.5  
NOTES  
PINꢀDESIGNATIONS  
Function  
1)  
M3 screws used to bolt unit’s baseplate to other surfaces (such as  
a heatsink) must not exceed 0.100” (2.54 mm) depth below the  
surface of the baseplate.  
Pin Name  
1
Vin(+)  
Positive input voltage  
2)  
3)  
4)  
Applied torque per screw should not exceed 6in-lb. (0.7 Nm).  
TTL input to turn converter on and off,  
referenced to Vin(–), with internal pull up.  
Baseplate flatness tolerance is 0.004” (.10mm) TIR for surface.  
2
ON/OFF  
Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080”  
(2.03mm) diameter standoff shoulders.  
Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100” (2.54  
mm) diameter standoff shoulders.  
All Pins: Material - Copper Alloy- Finish (RoHS 6/6) - Matte Tin  
over Nickel plate  
3
4
5
6
7
8
Vin(–)  
Vout(–)  
SENSE(–)  
TRIM  
Negative input voltage  
5)  
6)  
Negative output voltage  
Negative remote sense(see note 1)  
Output voltage trim (see note 2)  
Positive remote sense (see note 3)  
Positive output voltage  
7)  
8)  
Weight: 3oz (85g) typical  
All dimensions in inches (mm)  
SENSE(+)  
Vout(+)  
Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm)  
x.xxx +/-0.010 in. (x.xx +/-0.25mm)  
Workmanship: Meets or exceeds IPC-A-610C Class II  
9)  
Notes:  
10)  
Recommended pin length is 0.03” (0.76mm) greater than the  
PCB thickness.  
SENSE(–) should be connected to Vout(–) either remotely  
or at the converter.  
1)  
11)  
A thermal interface material is required to assure proper heat  
transfer from the baseplate to the cooling surface. Thermal  
grease may be used, or materials such as Thermalloy’s Grafoil  
or Burgquist’s HiFlow and Softflow. Other similar products are  
available from many heatsink manufacturers.  
2) Leave TRIM pin open for nominal output voltage.  
SENSE(+) should be connected to Vout(+) either remotely  
or at the converter.  
3)  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 27  
Technical  
Specification  
IQ90xxxQMXxx  
IQ90 QTV Mechanical Drawing  
.01 [0.2]  
OVERALL HEIGHT  
.500 ±.025  
[12.7 ±0.63]  
.60 [ 15.2  
.45 [ 11.4  
.30 [ 7.6 ]  
.15 [ 3.8 ]  
]
]
2.200 ±.020 [ 55.88 ±0.5]  
1.536 ±.020 [ 39.01 ±0.5]  
.18  
[ 4.6 ]  
SEE NOTE 5  
R .065  
4
5
6
7
8
[ 1,65 ]  
2.00  
[ 50.8  
TOP VIEW  
BOTTOM VIEW  
]
2.07  
[ 52.5]  
2.386 ±.020  
[ 60.6 ±0.5]  
1.66  
[ 42.2  
]
1.01  
[ 25.7  
]
.36  
[ 9.1 ]  
3
2
1
1
.70  
[ 17.8  
.183 ±.020  
[ 4.65 ±0.5]  
1.30  
[ 33]  
.30 [ 7.6 ]  
]
.13  
BOTTOMSIDE CLEARANCE  
NOTES  
PINꢀDESIGNATIONS  
Function  
1)  
2)  
Use 6 M3 or 4-40 size threaded screws. The screws should be  
tightened with a torque suitable to get a tight fitting of the  
converter against the cooling surface.  
Pin Name  
1
Vin(+)  
Positive input voltage  
Applied torque per screw should not exceed 5in-lb.  
(3in-lb recommended).  
Baseplate flatness tolerance is 0.004” (.10mm) TIR for surface.  
TTL input to turn converter on and off,  
referenced to Vin(–), with internal pull up.  
2
ON/OFF  
3)  
4)  
Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080” (2.03mm)  
diameter standoff shoulders.  
Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100" (2.54 mm)  
diameter standoff shoulders.  
All Pins: Material - Copper Alloy- Finish (RoHS 6/6) - Matte Tin over  
Nickel plate  
Total Weight: 3.123 oz (88.5 g)  
All dimensions in inches (mm)  
Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm)  
x.xxx +/-0.010 in. (x.xx +/-0.25mm)  
Workmanship: Meets or exceeds IPC-A-610C Class II  
Recommended pin length is 0.03” (0.76mm) greater than the  
PCB thickness.  
3
4
5
6
7
8
Vin(–)  
Vout(–)  
SENSE(–)  
TRIM  
Negative input voltage  
Negative output voltage  
5)  
6)  
Negative remote sense(see note 1)  
Output voltage trim (see note 2)  
Positive remote sense (see note 3)  
Positive output voltage  
7)  
8)  
SENSE(+)  
Vout(+)  
Notes:  
9)  
10)  
SENSE(–) should be connected to Vout(–) either remotely  
or at the converter.  
1)  
11)  
A thermal interface material is required to assure proper heat  
transfer from the flanged baseplate to the cooling surface. Thermal  
grease may be used, or materials such as Thermalloy’s Grafoil or  
Burgquist’s HiFlow and Softflow. Other similar products are available  
from many heatsink manufacturers.  
2) Leave TRIM pin open for nominal output voltage.  
SENSE(+) should be connected to Vout(+) either remotely  
3)  
or at the converter.  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 28  
Technical  
Specification  
IQ90xxxQMXxx  
PART NUMBERING SYSTEM  
ORDERING INFORMATION  
The tables below show the valid model numbers and ordering  
options for converters in this product family. When ordering  
SynQor converters, please ensure that you use the complete  
15 character part number consisting of the 12 character  
base part number and the additional characters for options.  
Add “-G” to the model number for 6/6 RoHS compliance.  
The part numbering system for SynQor’s dc-dc converters  
follows the format shown in the example below.  
IQ 90 018 Q M C 40 N R S - G  
6/6 RoHS  
Input Voltage  
Range  
Output  
Voltage  
1.8V  
3.3V  
5V  
7V  
12V  
15V  
24V  
30V  
48V  
Max Output  
Current  
Model Number  
Options (see  
Ordering Information)  
IQ90018QMw25xyz  
34-160V  
25A  
Output Current  
IQ90033QMw15xyz  
IQ90050QMw10xyz  
IQ90070QMw07xyz  
IQ90120QMw04xyz  
IQ90150QMw04xyz  
IQ90240QMw02xyz  
IQ90300QMw02xyz  
IQ90480QMw01xyz  
34-160V  
34-160V  
34-160V  
34-160V  
34-160V  
34-160V  
34-160V  
34-160V  
15A  
10A  
7A  
4A  
3.3A  
2A  
Thermal Design  
Performance Level  
Package Size  
Output Voltage  
1.6A  
1A  
Input Voltage  
Product Family  
The following options must be included in place of the w x y z  
spaces in the model numbers listed above.  
The first 12 characters comprise the base part number and  
the last 3 characters indicate available options. The “-G”  
suffix indicates 6/6 RoHS compliance.  
Options Description: w x y z  
Thermal Design  
Enable Logic Pin Style Feature Set  
C - Encased  
V - Encased with Flange  
N - Negative  
R - 0.180"  
S - Standard  
Application Notes  
Not all combinations make valid part numbers, please contact  
SynQor for availability. See the Product Summary web page for  
more options.  
A variety of application notes and technical white papers can  
be downloaded in pdf format from our website.  
RoHS Compliance: The EU led RoHS (Restriction of Hazardous  
Substances) Directive bans the use of Lead, Cadmium,  
Hexavalent Chromium, Mercury, Polybrominated Biphenyls  
(PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical  
and Electronic Equipment. This SynQor product is 6/6 RoHS  
compliant. For more information please refer to SynQor’s  
RoHS addendum available at our RoHS Compliance / Lead Free  
PATENTS  
SynQor holds the following U.S. patents, one or more of which  
apply to each product listed in this document. Additional patent  
applications may be pending or filed in the future.  
Initiative web page or e-mail us at rohs@synqor.com  
.
5,999,417  
6,731,520  
7,072,190  
7,272,023  
6,222,742  
6,894,468  
7,085,146  
7,558,083  
6,545,890  
6,896,526  
7,119,524  
7,564,702  
6,577,109  
6,927,987  
7,269,034  
6,594,159  
7,050,309  
7,272,021  
Contact SynQor for further information:  
Phone:  
Toll Free: 888-567-9596  
Fax:  
978-849-0600  
Warranty  
SynQor offers a two (2) year limited warranty. Complete warranty  
information is listed on our website or is available upon request from  
SynQor.  
978-849-0602  
E-mail:  
Web:  
power@synqor.com  
www.synqor.com  
Information furnished by SynQor is believed to be accurate and reliable.  
However, no responsibility is assumed by SynQor for its use, nor for any  
infringements of patents or other rights of third parties which may result  
from its use. No license is granted by implication or otherwise under any  
patent or patent rights of SynQor.  
Address: 155 Swanson Road  
Boxborough, MA 01719  
USA  
Product # IQ90xxxQMXxx  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005529 Rev. A  
05/04/10  
Page 29  

相关型号:

IQ90050HPC40NRS

Half-brick DC-DC Converter
SYNQOR

IQ90050HPC40NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT, HALF BRICK, PACKAGE-8
SYNQOR

IQ90050HPD40NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, ROHS COMPLIANT, HALF BRICK, PACKAGE-8
SYNQOR

IQ90050QMC10NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, ROHS COMPLIANT PACKAGE-8
SYNQOR

IQ90050QMV10NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, ROHS COMPLIANT PACKAGE-8
SYNQOR

IQ90070QMC07NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, ROHS COMPLIANT PACKAGE-8
SYNQOR

IQ90070QMV07NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, ROHS COMPLIANT PACKAGE-8
SYNQOR

IQ90120HPC19NRS

Half-brick DC-DC Converter
SYNQOR

IQ90120HPC19NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 228W, Hybrid, ROHS COMPLIANT, HALF BRICK, PACKAGE-8
SYNQOR

IQ90120HPD19NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 228W, Hybrid, ROHS COMPLIANT, HALF BRICK, PACKAGE-8
SYNQOR

IQ90150HPC15NRS

Half-brick DC-DC Converter
SYNQOR

IQ90150HPC15NRS-G

DC-DC Regulated Power Supply Module, 1 Output, 225W, Hybrid, ROHS COMPLIANT, HALF BRICK, PACKAGE-8
SYNQOR