MA24D [SYSTEMSENSOR]

Multi-Alert & Mini-Alert Sounders and Strobes; 多警报和迷你警报蜂鸣器及频闪灯
MA24D
型号: MA24D
厂家: SYSTEMSENSOR ADVANCED IDEAS.    SYSTEMSENSOR ADVANCED IDEAS.
描述:

Multi-Alert & Mini-Alert Sounders and Strobes
多警报和迷你警报蜂鸣器及频闪灯

文件: 总2页 (文件大小:71K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Multi-Alert & Mini-Alert  
Sounders and Strobes  
Multi-Alert Models  
Sounder  
MA12/24D  
Strobes  
SS24LO  
SS24M  
Sounder/Strobes  
MASS24LO  
MASS24M  
SS24LOLA  
MASSLOLA  
Mini-Alert Sounders  
PA
Red  
Beige  
White  
PA400  
PA400R-F PA400B-F  
PA400  
PA400W  
PA400W-F  
Add-on Strobes  
MA12/24D  
PA400R-F  
Red  
White  
PS24LO  
PS24LOW  
Product Overview  
System Sensor's Multi-Alert sounder and sounder/strobes are suited to provide primary  
or secondary signaling for fire and security applications. The MA and MASS models  
provide eight field-selectable warning tones.  
Multi-Alert Sounder:  
12 and 24V operation  
8 field-selectable tones  
The Multi-Alert models mount directly to 4square back boxes. Optional mounting  
plates are available for either flush or semi-flush installations. Model MA12/24D is suitable  
for outdoor applications when installed with the WBB weather-proof back box.  
Multi-Alert Strobes and Sounder/Strobes:  
24V operation  
1.5 or 15 candela  
UL1638 listed  
Multi-Alert Strobes. System Sensor’s Multi-Alert strobes are UL1638 compliant  
electronic visible warning signals that flash approximately every 1.5 seconds. All  
circuits are polarized to be compatible with DC alarm supervision.  
Mini-Alert Sounders:  
12 and 24V operation  
1.5 cd add-on strobe available  
Mini-Alert Sounders. System Sensor’s PA400 series Mini-Alert sounders operate  
at 12 and 24 volts and are ideal for hotel, motel or residential fire system  
applications, where a smaller notification device is desired. The PA400  
sounders are available with or without FIRE identification, and are offered in  
red, beige, and white.  
Engineering Specifications  
Multi-Alert Sounders shall be a System Sensor Model MA 12/24D capable of operating at 12 and 24VDC. Sounder shall be  
listed to Underwriter’s Laboratories Standard UL464 for fire protective signaling systems. Sounder shall have an operating  
temperature between –31°F and 151°F. Sounder shall have eight tone options, selected by means of clips.  
Mini-Alert Sounders shall be a System Sensor Model  
to Underwriter's Laboratories Standard UL464 for fire protective signaling systems. Sounder shall have an operating tem-  
perature between 14°F and 140°F.  
capable of operating at 12 and 24VDC. Sounder shall be listed  
———  
Multi-Alert and Mini-Alert Sounder/Strobes shall be a System Model  
capable of operating at 24VDC. Sounder/strobe  
———  
shall be listed to Underwriter’s Laboratories Standards UL464 and UL1638 for fire protective signaling systems.  
Sounder/strobe shall have an operating temperature between 32°F and 120°F. Strobe shall be powered independently of the  
sounder and shall operate at 24VDC, with a UL range rating of 22.5 to 30VDC. Actual operating voltage must be between  
18 and 33VDC. Strobe shall have a minimum light output of 1.5 or 15 candela and shall be UL1638 listed for private  
mode applications.  
Multi-Alert Sounder Specifications  
Dimensions  
Mounting  
Surface  
Flush  
Operating Temperature Range  
–32° to 151°F (–35° to 66°C)  
4x 4back box (11/2to 21/8deep)  
4x 4BBD deep back box (23/4deep)  
4x 4x 21/4″  
Semi-flush 4x 4back box (11/2to 21/8deep)  
Weight  
5.7 oz. (162 g)  
with MP-SF mounting plate  
Operating Voltage  
12VDC to 24VDC FWR unfiltered*  
Input Terminals  
12 to 18 AWG  
*Actual 12 V operating voltage cannot be less than 9.6VDC or greater than 18.7VDC.  
Actual 24 V operating voltage cannot be less than 18VDC or greater than 33VDC.  
Multi-Alert Strobe Specifications  
Dimensions  
4x 4x 215/16″  
Mounting  
Surface  
Operating Temperature Range  
–31° to 151°F (–35° to 66°C)  
4x 4back box (11/2to 21/8deep)  
Semi-flush 4x 4back box (11/2to 21/8deep)  
with MP-SF mounting plate  
Weight  
8.2 oz. (232 g)  
Input Terminals  
12 to 18 AWG  
Operating Voltage  
24VDC and FWR unfiltered*  
*Actual 24V operating voltage cannot be less than 18VDC or greater than 33VDC.  
Mini-Alert Specifications  
Dimensions  
41/2x 23/4x 11/8″  
Mounting  
Surface  
Flush  
Operating Temperature Range  
14° to 140°F (–10° to 60°C)  
Single gang back box  
4x 4BBD deep back box (23/4deep)  
Weight  
2.4 oz. (159 g)  
Input Terminals  
12 to 18 AWG  
Operating Voltage  
12VDC to 24VDC FWR unfiltered*  
*Actual 12V operating voltage cannot be less than 9.6VDC or greater than 18.7VDC.  
Actual 24V operating voltage cannot be less than 18VDC or greater than 33VDC.  
Ordering Information/Current Draw  
Multi-Alert/Mini-Alert Model Numbers  
Average  
Current  
dB Output  
(UL)***  
Red  
Beige  
White  
Description  
Voltage  
12/24VDC  
24VDC  
24VDC  
24VDC  
24VDC  
24VDC  
Candela  
MA12/24D  
SS24LO  
Multi-Alert sounder  
*
75–85  
Multi-Alert strobe  
25 mA  
75 mA  
25 mA  
**  
1.5  
SS24M  
Multi-Alert strobe  
15.0  
1.5  
SS24LOLA  
MASS24LO  
MASS24M  
MASS24LOLA  
PA400R  
Multi-Alert strobe (“FUEGO” lens)  
Multi-Alert sounder /strobe  
Multi-Alert sounder /strobe  
1.5  
75–85  
75–85  
75–85  
82  
**  
15.0  
1.5  
Multi-Alert sounder/strobe (“FUEGO” lens) 24VDC  
**  
PA400B  
PA400W  
PA400W-F  
PS24LOW  
Mini-Alert sounder  
12/24VDC  
12/15 mA  
12/15 mA  
5 mA  
PA400R-F  
PS24LO  
PA400B-F  
Mini-Alert sounder (“Fire” identification)  
Add-on strobe  
12/24VDC  
12/24VDC  
82  
1.5  
82  
Accessory Model Numbers  
Description  
MP-F/MP-FB  
MP-SF/MP-SFB  
BB-D  
Flush mounting plate (red/beige)  
Semi-flush mounting plate (red/beige)  
Flush mounting deep back box, 23/4deep  
WBB  
Weatherproof back box for MA 12/24D  
* Current ranges from 10mA to 55mA depending upon voltage and sound selected  
** Current ranges from 35mA to 80mA depending upon voltage and sound selected  
*** Sound output varies depending upon voltage and sound selected.  
Note: LO and M style strobe and sounder/strobe models are not MEA approved.  
System Sensor Sales and Service  
System Sensor Headquarters  
3825 Ohio Avenue  
St. Charles, IL 60174  
Ph: 800-SENSOR2  
Fx: 630/377-6495  
Documents on Demand  
1-800-736-7672 x3  
System Sensor Canada  
Ph: 905.812.0767  
Fx: 905.812.0771  
System Sensor in China  
Ph: 011.86.29.524.6253  
Fx: 011.86.29.524.6259  
System Sensor– Far East  
Ph: 011.85.22.191.9003  
Fx: 011.85.22.736.6580  
System Sensor Europe  
Ph: 011.44.1403.276500  
Fx: 011.44.1403.276501  
System Sensor in Singapore  
Ph: 011.65.273.2230  
Fx: 011.65.273.2610  
System Sensor– Australia  
Ph: 011.613.54.281.142  
Fx: 011.613.54.281.172  
www.systemsensor.com  
© 1999 System Sensor. The company reserves the right to change product specifications without notice.  
A05-207-07•11/99(10K)•#571  

相关型号:

MA24D50

Rectifier Diode, Schottky, 1 Phase, 1 Element, 3A, Silicon, TMINIP2-F1, 2 PIN
PANASONIC

MA24D51

Rectifier Diode, Schottky, 1 Phase, 1 Element, 3A, 40V V(RRM), Silicon, ROHS COMPLIANT, TMINIP2-F1, 2 PIN
PANASONIC

MA24D54

Rectifier Diode, Schottky, 1 Phase, 1 Element, 3A, Silicon, TMINIP2-F1, 2 PIN
PANASONIC

MA24D58

Rectifier Diode, Schottky, 1 Phase, 1 Element, 3A, Silicon, ROHS COMPLIANT, TMINIP2-F1, 2 PIN
PANASONIC

MA24D60

Rectifier Diode, Schottky, 1 Phase, 1 Element, 2A, 40V V(RRM), Silicon, ROHS COMPLIANT, TMINIP2-F1, 2 PIN
PANASONIC

MA24D61

Rectifier Diode, Schottky, 1 Phase, 1 Element, 2A, Silicon, TMINIP2-F1, 2 PIN
PANASONIC

MA24D62

Rectifier Diode, Schottky, 1 Phase, 1 Element, 2A, Silicon, ROHS COMPLIANT, TMINIP2-F1, 2 PIN
PANASONIC

MA24D70

Rectifier Diode, Schottky, 1 Phase, 1 Element, 5A, Silicon, TMINIP2-F1, 2 PIN
PANASONIC

MA24D74

Rectifier Diode, Schottky, 1 Phase, 1 Element, 5A, Silicon, TMINIP2-F1, 2 PIN
PANASONIC

MA24F41

Rectifier Diode, 1 Element, 1A, 400V V(RRM), Silicon, ROHS COMPLIANT, TMINIP2-F1, 2 PIN
PANASONIC

MA24F70

Rectifier Diode, 1 Element, 1A, 700V V(RRM), Silicon, ROHS COMPLIANT, TMINIP2-F1, 2 PIN
PANASONIC

MA24FAA

14 pin DIP, 5.0 Volt, ACMOS/TTL, Clock Oscillator
MTRONPTI