SA-WBBCW [SYSTEMSENSOR]
Outdoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications;型号: | SA-WBBCW |
厂家: | SYSTEMSENSOR ADVANCED IDEAS. |
描述: | Outdoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications |
文件: | 总4页 (文件大小:569K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Outdoor Selectable-
Output Strobes and
Horn Strobes for
Ceiling Applications
SpectrAlert® Advance outdoor audible visible products
are rich with features that cut installation times and
maximize profits.
Features
SpectrAlert Advance offers the broadest line of outdoor horns,
strobes, and horn strobes in the industry. With white or red plastic
housings, wall or ceiling mounting options, and plain or FIRE-printed
devices, SpectrAlert Advance can meet virtually any application
requirement, including indoor, outdoor, wet, and dry applications in
temperatures from −40°F to 151°F.
• Weatherproof NEMA 4X, IP56 rated
• Listed to UL 1638 (strobe) and UL 464 (horn)
• Compatible with System Sensor synchronization protocol and
legacy SpectrAlert products
• Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115,
135, 150, 177, and 185
Like the entire SpectrAlert Advance line, outdoor strobes and horn
strobes for ceiling applications include a variety of features that
increase application flexibility and simplify installation. First, field-
selectable settings, including candela, automatic selection of 12- or
24-volt operation, horn tones, and three volume options enable
installers to easily adapt devices to meet requirements.
• Automatic selection of 12- or 24-volt operation at 15 and
15/75 candela
• Rotary switch for horn tone and three volume selections
• Horn rated at 88+ dBA at 16 volts
• Rated from –40°F to 151°F
Next, SpectrAlert Advance devices use a universal mounting plate
for both wall and ceiling applications. This mounting plate includes
an onboard shorting spring that ensures wiring continuity before
devices are installed, so installers can verify proper wiring without
mounting the devices and exposing them to potential construction
damage. Once the plates are mounted, all SpectrAlert Advance
devices utilize a plug-in design with a single captured screw to
speed installation and virtually eliminate costly ground faults.
• Universal mounting plate with an onboard shorting spring that
tests wiring continuity before devices are installed
• Plug-in design with minimal intrusion into the back box
• Tamper-resistant construction
• Listed for ceiling or wall mounting
Outdoor devices ship with weatherproof plastic back boxes (metal
back boxes are available separately) that accommodate in-and-
out wiring for daisy chaining devices. Plastic back boxes feature
removable side flanges and improved resistance to saltwater
corrosion. Plastic and metal weatherproof back boxes come with
¾-inch top and bottom conduit entries and ¾-inch knock-outs at the
back. Three screw-in NPT plugs with O-ring gaskets for a watertight
seal is included with each back box.
Agency Listings
7300-1653:187 (outdoor strobes)
7125-1653:188 (horn strobes,
chime strobes)
7135-1653:189 (horns, chimes)
S4011 (chimes, horn strobes, horns)
S3593 (outdoor and alert strobes)
3023572
MEA452-05-E
SpectrAlert Advance Outdoor Strobe, and Horn Strobe Specifications
Architect/Engineer Specifications
General
SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall
be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate.
Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification
appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification
appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between
16.5 and 33 volts. Outdoor SpectrAlert Advance products shall operate between −40 and 151 degrees Fahrenheit from a regulated DC or full-
wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95,
110, 115, 135, 150, 177, and 185.
Strobe
The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1638 and shall be approved for fire protective service.
The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for
visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash
tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved
per UL. The strobe shall be suitable for use in wet environments.
Horn Strobe Combination
The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1638 and UL 464 and shall be approved for
fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with
Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light
shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch
between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-
wire products, the strobe shall be powered independently of the sounder. The horn strobe on a 2-wire model shall work on a non-coded power
supply. The horn on 4-wire horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with
its weatherproof back box in order to remain outdoor listed per UL. The horn strobe shall be suitable for use in wet environments.
Physical/Electrical Specifications
Operating Temperature
–40°F to 151°F (–40°C to 66°C)
Strobe Flash Rate
1 flash per second
Nominal Voltage
Operating Voltage Range2
Regulated 12 DC/FWR or regulated 24 DC/FWR1
8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal)
8.5 to 17.5V (12 V nominal) or 16.5 to 33V (24 V nominal)
12 to 18 AWG
Operating Voltage Range with MDL3 Sync Module
Input Terminal Wire Gauge
Ceiling-Mount Dimensions (including lens)
Strobe / Horn Strobe Dimensions
Strobe / Horn Strobe Dimensions with Back Box
Ceiling-Mount Weatherproof Back Box Dimensions
Notes:
6.8˝ diameter × 2.5˝ high (173 mm diameter × 64 mm high)
5.6˝ L × 4.7˝ W × 1.3˝ D (142 mm L × 119 mm W × 33 mm D)
5.6˝ L × 4.7˝ W × 1.3˝ D (142 mm L × 119 mm W × 33 mm D)
7.1˝ diameter × 2.0˝ high (180 mm diameter × 51 mm high)
1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs.
2. Products will operate at 12 V nominal only for 15 and 15/75 cd.
AVDS11401
UL Current Draw Data
UL Max. Strobe Current Draw (mA RMS)
UL Max. Horn Current Draw for 4-Wire Horn Strobes (mA RMS)
8–17.5 Volts 16–33 Volts
8–17.5 Volts
16–33 Volts
Candela DC
FWR
DC
66
77
FWR
Sound Pattern
Temporal
Temporal
dB
DC
57
44
38
57
42
41
57
44
40
FWR
DC
69
58
44
69
60
50
69
56
52
FWR
Standard
Candela
Range
15
123
142
NA
NA
NA
NA
NA
NA
NA
NA
NA
128
148
NA
NA
NA
NA
NA
NA
NA
NA
NA
71
81
High
Medium
Low
High
Medium
Low
High
Medium
Low
55
49
44
56
50
44
55
51
46
75
69
48
75
69
50
75
69
50
15/75
30
Temporal
94
96
Non-Temporal
Non-Temporal
Non-Temporal
Coded
Coded
Coded
75
95
158
181
202
210
228
246
281
286
153
176
195
205
207
220
251
258
110
115
135
150
177
185
High
Candela
Range
UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15–115 cd)
8–17.5 Volts
15
16–33 Volts
DC Input
15/75
147
144
143
152
145
144
15
79
69
66
91
75
68
15/75
90
80
77
100
85
30
75
95
110
212
201
198
221
207
201
115
Temporal High
Temporal Medium
Temporal Low
Non-Temporal High
Non-Temporal Medium
Non-Temporal Low
FWR Input
137
132
132
141
133
131
107
97
93
116
102
96
176
157
154
176
163
156
194
182
179
201
187
182
218
210
207
229
216
210
79
Temporal High
Temporal Medium
Temporal Low
Non-Temporal High
Non-Temporal Medium
Non-Temporal Low
136
129
129
142
134
132
155
152
151
161
155
154
88
78
76
103
85
80
97
88
86
112
95
90
112
103
101
126
110
105
168
160
160
181
166
161
190
184
184
203
189
184
210
202
194
221
208
202
218
206
201
229
216
211
UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135–185 cd)
16–33 Volts
16–33 Volts
DC Input
135
245
235
232
255
242
238
150
259
253
251
270
259
254
177
290
288
282
303
293
291
185
297
297
292
309
299
295
FWR Input
135
215
209
207
233
219
214
150
177
185
Temporal High
Temporal Medium
Temporal Low
Non-Temporal High
Non-Temporal Medium
Non-Temporal Low
Temporal High
Temporal Medium
Temporal Low
Non-Temporal High
Non-Temporal Medium
Non-Temporal Low
231
224
221
248
232
229
258
250
248
275
262
256
265
258
256
281
267
262
Candela Derating
HornTones and Sound Output Data
For K series products used at low temperatures, listed
candela ratings must be reduced in accordance with
this table.
Horn Strobe Output (dBA)
24-Volt Nominal
Reverberant Anechoic
DC FWR DC FWR DC FWR DC FWR
8–17.5
Volts
16–33
Volts
Switch
Position Pattern
Sound
Strobe Output (cd)
dB
Temporal High
Temporal Medium 74 74
Listed Candela
Candela rating at –40°F
1
2
3
4
78 78
84 84
80 80
76 76
88
86
83
88
86
80
99 98
96 96
94 89
15
15/75
30
Do not use below 32°F
Temporal Low
Non-
Temporal
Non-
Temporal
Non-
Temporal
Coded
Coded
Coded
71 73
High
82 82
88 88
85 85
81 81
93
90
88
92
90
84
100 100
98 98
96 92
75
44
95
70
5
6
Medium
Low
78 78
110
115
135
150
177
185
110
115
135
150
177
185
75 75
82 82
Medium 78 78
Low 75 75
7†
8†
9†
High
88 88
85 85
81 81
93
90
88
92
90
85
101 101
97 98
96 92
†Settings 7, 8, and 9 are not available on 2-wire horn strobe.
AVDS11401
SpectrAlert Advance Diagrams
6.8˝
Dia.
2.5˝
Ceiling Plastic Weatherproof Back Box
Ceiling-Mount Horn Strobes
Ceiling-Mount Horn Strobe with Plastic Weatherproof Back Box
SpectrAlert Advance Ordering Information
Model
Description
Ceiling Horn Strobes
PC2RK
PC2RHK
2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box)
2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box)
2-Wire, Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box)
2-Wire, Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box)
PC2WK
PC2WHK
Ceiling Strobes
SCRK
SCRHK
SCWK
Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box)
Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box)
Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box)
Strobe, High cd, White, Outdoor (includes plastic weatherproof back box)
SCWHK
Accessories
SA-WBBC
SA-WBBCW
MP120K
Red, Metal Weatherproof Back Box
White, Metal Weatherproof Back Box
Notes:
“Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd” refers to strobes that include 135, 150, 177, and 185
candela settings. When replacing outdoor units, both the device and back box must be replaced.
©2015 System Sensor.
3825 Ohio Avenue • St. Charles, IL 60174
Phone: 800-SENSOR2 • Fax: 630-377-6495
Product specifications subject to change without notice. Visit systemsensor.com
for current product information, including the latest version of this data sheet.
AVDS11402 • 02/15
相关型号:
©2020 ICPDF网 联系我们和版权申明