PC30.09.0100A [TAOGLAS]

FR4 Penta-band GSM Antenna 100mm 1.13 coax MMCX(M)RA;
PC30.09.0100A
型号: PC30.09.0100A
厂家: Taoglas    Taoglas
描述:

FR4 Penta-band GSM Antenna 100mm 1.13 coax MMCX(M)RA

GSM
文件: 总7页 (文件大小:459K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
SPECIFICATION  
Part No.  
: PC30.09.0100A  
Product Name  
Feature  
: FR4 Penta-band GSM Antenna  
100mm 1.13 coax MMCX(M)RA  
: High antenna RF efficiency  
RoHS compliant  
SPE-12-8-058/A/ZL  
Page 1 of 7  
I. Introduction  
PC30 is a custom-designed FR4 quad-band GSM antenna for a tracking device.  
This RoHS compliant antenna has high RF efficiency with the tracking device to  
meet PTCRB requirement.  
II. Specification (Free Space)  
Specifications  
Penta-band Cellular  
Communication System  
AMPS  
824 ~ 896 880~960 1710~1880  
17% 38% 60%  
2dBi  
50 Ohm  
GSM  
DCS  
PCS  
1850~1990  
70%  
UMTS  
1710~2170  
68%  
Frequency (MHz)  
Average Efficiency  
Gain  
Impedance  
Radiation Pattern  
Polarization  
Omni-directional  
Linear  
PCB  
FR4 74.70 x 8.20 x 0.8 mm  
MMCX(M)RA  
Connector  
1.13  
Cable  
Cable Length  
Operation Temperature  
Storage Temperature  
100 mm  
-40°C ~ +85°C  
-40°C ~ +85°C  
Please note that Cables and Connectors are Customizable, customized solution will have an MOQ  
SPE-12-8-058/A/ZL  
Page 2 of 7  
III. Electrical Property  
III.1 Test Setup  
Satimo SG64 3D-chamber is used for radiation and efficiency test. For the free  
space test, a Styrofoam is used to fix the antenna in the testing set.  
z
y
x
Antenna setup and Satimo SG64 3D-chamber.  
SPE-12-8-058/A/ZL  
Page 3 of 7  
III.2 Radiation Pattern  
The radiation pattern of PC.30 in free space as the above test setup is --  
Radiation pattern of x-y plane  
Radiation pattern of x-z plane  
SPE-12-8-058/A/ZL  
Page 4 of 7  
III.3 Efficiency  
80.00%  
70.00%  
60.00%  
50.00%  
40.00%  
30.00%  
20.00%  
10.00%  
0.00%  
600  
1000  
1400  
1800  
2200  
Frequency (MHz)  
SPE-12-8-058/A/ZL  
Page 5 of 7  
III.4 Return Loss  
A piece of Styrofoam is use to hold PC.30 at least 30cm away from any metal  
surrounding objects. Agilent E5071B Network Analyzer is used for the return  
loss measurement.  
0.0  
-1.0  
-2.0  
-3.0  
-4.0  
-5.0  
-6.0  
-7.0  
-8.0  
-9.0  
-10.0  
-11.0  
-12.0  
-13.0  
-14.0  
-15.0  
-16.0  
-17.0  
-18.0  
-19.0  
-20.0  
-21.0  
0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0  
Frequency (GHz)  
SPE-12-8-058/A/ZL  
Page 6 of 7  
IV. Drawing  
SPE-12-8-058/A/ZL  
Page 7 of 7  

相关型号:

PC30/25-0&FP30/25

GEHAEUSE WAND KLARSICHTDECKEL AUSF 2
ETC

PC30070100A

FR4 Penta-band GSM Antenna
ETC

PC30090100A

FR4 Penta-band GSM Antenna 100mm 1.13 coax MMCX(M)RA
ETC

PC3012

30A Avg 1200 1600 Volts
NIEC

PC3012_1

30A Avg 1200 1600 Volts
NIEC

PC3016

30A Avg 1200 1600 Volts
NIEC

PC302S

Microminiature Surface Mount Signal Relay
PICKER

PC303

Microminiature Signal Relay
PICKER

PC303-12

Microminiature Signal Relay
PICKER

PC303-12L1

Microminiature Signal Relay
PICKER

PC303-12L1X

Microminiature Signal Relay
PICKER

PC303-12X

Microminiature Signal Relay
PICKER