B59100C0130A070 [TDK]
PTC温限传感器(传感器);型号: | B59100C0130A070 |
厂家: | TDK ELECTRONICS |
描述: | PTC温限传感器(传感器) 温度传感 传感器 电阻器 |
文件: | 总10页 (文件大小:675K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PTC thermistors as limit temperature sensors
Series/Type:
B59100
The following products presented in this data sheet are being withdrawn.
Ordering Code
Substitute Product
Date of Withdrawal Deadline Last
Orders
Last Shipments
B59100C0090A070
2023-06-09
2023-09-22
2023-12-22
Please contact your nearest TDK sales office if you need support in selecting a suitable substitute. The addresses of
our worldwide sales network are presented at www.tdk-electronics.tdk.com/sales.
Sensors
Limit temperature sensors, leaded disks, coated
C100
Applications
Dimensional drawing
Limit temperature monitoring
Features
Tinned leads
Manufacturer's logo and type designation
stamped on in white
Characteristics for sensing temperatures of
90 to 140 °C conform with
DIN VDE V 0898-1-401
RoHS-compatible
Delivery mode
Cardboard strips (standard), cardboard tape
reeled or in Ammo pack on request
Dimensions in mm
General technical data
Max. operating voltage
Measuring voltage1)
Max. measuring voltage1)
(TA = 0 ... 40 °C)
(TA = ꢀ40 °C ... Tsense +5 K) Vmeas
For TA see table "Electrical Vmeas,max 7.5
specifications"
Vmax
30
≤ 2.5
V DC
V DC
V DC
Rated resistance
Operating temperature range
Operating temperature range
(VPTC ≤ 2.5 V)
(V ≤ Vmeas,max
(V = Vmax
RR
Top
Top
≤ 100
ꢀ40/ Tsense +23 °C
0/+40 °C
Ω
)
)
1) Vmeas and Vmeas,max for 90 °C ≤ Tsense ≤ 140 °C acc. to DIN VDE V 0898-1-401.
Electrical specifications and ordering codes
Tsense
R
R
R
R
Ordering code
(Tsense ꢀ ∆T)
(VPTC ≤ 2.5 V)
Ω
(Tsense + ∆T)
(VPTC ≤ 2.5 V)
Ω
(Tsense + 15 K) (Tsense + 23 K)
(VPTC ≤ 7.5 V)
(VPTC ≤ 7.5 V)
°C
Ω
Ω
∆T = ±5 K
80
90
≤ 570
≤ 550
≤ 550
≤ 550
≤ 550
≤ 550
≤ 550
≥ 570
-
≥ 10 k
B59100C0080A070
B59100C0090A070
B59100C0100A070
B59100C0110A070
B59100C0120A070
B59100C0130A070
B59100C0140A070
≥ 1330
≥ 1330
≥ 1330
≥ 1330
≥ 1330
≥ 1330
≥ 4 k
≥ 4 k
≥ 4 k
≥ 4 k
≥ 4 k
≥ 4 k
-
-
-
-
-
-
100
110
120
130
140
Please read Cautions and warnings and
Important notes at the end of this document.
Page 2 of 10
Sensors
Limit temperature sensors, leaded disks, coated
C100
Reliability data
Test
Standard
Test conditions
ꢁ∆R25/R25ꢁ
Electrical endurance, IEC 60738-1
constant
Storage at Vmax and Top,max (@ Vmax
Test duration: 1000 h
)
< 25%
Damp heat
IEC 60738-1
IEC 60738-1
IEC 60738-1
Temperature of air: 40 °C
Relative humidity of air: 93%
Duration: 56 days
< 10%
< 25%
< 5%
Test according to IEC 60068-2-78
Rapid change
of temperature
T1 = Top,min (0 V), T2 = Top,max (0 V)
Number of cycles: 5
Test duration: 30 min
Test according to IEC 60068-2-14, test Na
Vibration
Frequency range: 10 to 55 Hz
Displacement amplitude: 0.75 mm
Test duration: 3 × 2 h
Test according to IEC 60068-2-6, test Fc
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 10
Sensors
Limit temperature sensors, leaded disks, coated
C100
Characteristics (typical)
PTC resistance RPTC versus PTC temperature TPTC
(measured at low signal voltage)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 4 of 10
Sensors
Limit temperature sensors, leaded disks, coated
C100
Cautions and warnings
General
TDK Electronics thermistors are designed for specific applications and should not be used for
purposes not identified in our specifications, application notes and data books unless otherwise
agreed with TDK Electronics during the design-in-phase.
Ensure suitability of thermistor through reliability testing during the design-in phase. The ther-
mistors should be evaluated taking into consideration worst-case conditions.
Storage
Store thermistors only in original packaging. Do not open the package prior to processing.
Storage conditions in original packaging: storage temperature ꢀ25 °C ... +45 °C, relative hu-
midity ≤75% annual mean, maximum 95%, dew precipitation is inadmissible.
Avoid contamination of thermistors surface during storage, handling and processing.
Avoid storage of thermistor in harmful environment with effect on function on long-term opera-
tion (examples given under operation precautions).
Use thermistor within the following period after delivery:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Through-hole devices (housed and leaded PTCs): 24 months
Motor protection sensors, glass-encapsulated sensors and probe assemblies: 24 months
Telecom pair and quattro protectors (TPP, TQP): 24 months
Leadless PTC thermistors for pressure contacting: 12 months
Leadless PTC thermistors for soldering: 6 months
SMDs in EIA sizes 3225 and 4032, and for PTCs with metal tags: 24 months
SMDs in EIA sizes 1210 and smaller: 12 months
Handling
PTCs must not be dropped. Chip-offs must not be caused during handling of PTCs.
The ceramic and metallization of the components must not be touched with bare hands. Gloves
are recommended.
Avoid contamination of thermistor surface during handling.
Soldering (where applicable)
Use rosin-type flux or non-activated flux.
Insufficient preheating may cause ceramic cracks.
Rapid cooling by dipping in solvent is not recommended.
Complete removal of flux is recommended.
Standard PTC heaters are not suitable for soldering.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 5 of 10
Sensors
Limit temperature sensors, leaded disks, coated
C100
Mounting
Electrode must not be scratched before/during/after the mounting process.
Contacts and housing used for assembly with thermistor have to be clean before mounting. Es-
pecially grease or oil must be removed.
When PTC thermistors are encapsulated with sealing material, the precautions given in chapter
"Mounting instructions", "Sealing and potting" must be observed.
When the thermistor is mounted, there must not be any foreign body between the electrode of
the thermistor and the clamping contact.
The minimum force and pressure of the clamping contacts pressing against the PTC must be
10 N and 50 kPa, respectively. In case the assembly is exposed to mechanical shock and/ or
vibration this force should be higher in order to avoid movement of the PTC during operation.
During operation, the thermistor’s surface temperature can be very high. Ensure that adjacent
components are placed at a sufficient distance from the thermistor to allow for proper cooling at
the thermistors.
Ensure that adjacent materials are designed for operation at temperatures comparable to the
surface temperature of thermistor. Be sure that surrounding parts and materials can withstand
this temperature.
Avoid contamination of thermistor surface during processing.
Operation
Use thermistors only within the specified temperature operating range.
Use thermistors only within the specified voltage and current ranges.
Environmental conditions must not harm the thermistors. Use thermistors only in normal at-
mospheric conditions. Avoid use in deoxidizing gases (chlorine gas, hydrogen sulfide gas, am-
monia gas, sulfuric acid gas etc), corrosive agents, humid or salty conditions. Contact with any
liquids and solvents should be prevented.
Be sure to provide an appropriate fail-safe function to prevent secondary product damage
caused by abnormal function (e.g. use VDR for limitation of overvoltage condition).
This listing does not claim to be complete, but merely reflects the experience of TDK Electronics.
Display of ordering codes for TDK Electronics products
The ordering code for one and the same product can be represented differently in data sheets,
data books, other publications, on the company website, or in order-related documents such as
shipping notes, order confirmations and product labels. The varying representations of the
ordering codes are due to different processes employed and do not affect the
specifications of the respective products. Detailed information can be found on the Internet
under www.tdk-electronics.tdk.com/orderingcodes.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 6 of 10
Sensors
Limit temperature sensors, leaded disks, coated
C100
Symbols and terms
Symbol
A
Term
Area
C
Capacitance
Cth
f
Heat capacity
Frequency
I
Current
Imax
IR
Maximum current
Rated current
Ires
Residual current
IPTC
Ir
PTC current
Residual currrent
Ir,oil
Ir,air
IRMS
IS
Residual currrent in oil (for level sensors)
Residual currrent in air (for level sensors)
Root-mean-square value of current
Switching current
ISmax
LCT
N
Maximum switching current
Lower category temperature
Number (integer)
Nc
Operating cycles at Vmax, charging of capacitor
Switching cycles at Vmax, failure mode
Power
Nf
P
P25
Pel
Maximum power at 25 °C
Electrical power
Pdiss
RG
Rmin
RR
Dissipation power
Generator internal resistance
Minimum resistance
Rated resistance @ rated temperature TR
Tolerance of RR
∆RR
RP
Parallel resistance
RPTC
Rref
RS
PTC resistance
Reference resistance
Series resistance
R25
R25,match
∆R25
Resistance at 25 °C
Resistance matching per reel/ packing unit at 25 °C
Tolerance of R25
Please read Cautions and warnings and
Important notes at the end of this document.
Page 7 of 10
Sensors
Limit temperature sensors, leaded disks, coated
C100
T
Temperature
t
Time
TA
Ambient temperature
ta
Thermal threshold time
TC
Ferroelectric Curie temperature
Settling time (for level sensors)
Rated temperature @ 25 °C or otherwise specified in the data sheet
Sensing temperature
tE
TR
Tsense
Top
Operating temperature
TPTC
tR
PTC temperature
Response time
Tref
Reference temperature
TRmin
tS
Temperature at minimum resistance
Switching time
Tsurf
UCT
V or Vel
Vc(max)
VF,max
VRMS
VBD
Vins
Vlink,max
Vmax
Vmax,dyn
Vmeas
Vmeas,max
VR
Surface temperature
Upper category temperature
Voltage (with subscript only for distinction from volume)
Maximum DC charge voltage of the surge generator
Maximum voltage applied at fault conditions in protection mode
Root-mean-square value of voltage
Breakdown voltage
Insulation test voltage
Maximum link voltage
Maximum operating voltage
Maximum dynamic (short-time) operating voltage
Measuring voltage
Maximum measuring voltage
Rated voltage
VPTC
α
Voltage drop across a PTC thermistor
Temperature coefficient
∆
Tolerance, change
δth
Dissipation factor
τth
Thermal cooling time constant
Failure rate
λ
Lead spacing (in mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 8 of 10
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical re-
quirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, we are either unfamiliar with individual customer applications or less familiar with
them than the customers themselves. For these reasons, it is always ultimately incumbent on
the customer to check and decide whether a product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Ma-
terial Data Sheets on the Internet (www.tdk-electronics.tdk.com/material). Should you have
any more detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the fore-
going for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to our General
Terms and Conditions of Supply.
Page 9 of 10
Important notes
7. Our manufacturing sites serving the automotive business apply the IATF 16949 stan-
dard. The IATF certifications confirm our compliance with requirements regarding the quality
management system in the automotive industry. Referring to customer requirements and cus-
tomer specific requirements (“CSR”) TDK always has and will continue to have the policy of
respecting individual agreements. Even if IATF 16949 may appear to support the acceptance
of unilateral requirements, we hereby like to emphasize that only requirements mutually
agreed upon can and will be implemented in our Quality Management System. For clari-
fication purposes we like to point out that obligations from IATF 16949 shall only become
legally binding if individually agreed upon.
8. The trade names EPCOS, CarXield, CeraCharge, CeraDiode, CeraLink, CeraPad, CeraPlas,
CSMP, CTVS, DeltaCap, DigiSiMic, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue,
MiniCell, MKD, MKK, ModCap, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap,
PowerHap, PQSine, PQvar, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID,
SineFormer, SIOV, ThermoFuse, WindCap, XieldCap are trademarks registered or pend-
ing in Europe and in other countries. Further information will be found on the Internet at
www.tdk-electronics.tdk.com/trademarks.
Release 2020-06
Page 10 of 10
相关型号: