B59154U1135B140 [TDK]

通讯保护用PTC;
B59154U1135B140
型号: B59154U1135B140
厂家: TDK ELECTRONICS    TDK ELECTRONICS
描述:

通讯保护用PTC

文件: 总14页 (文件大小:333K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
PTC thermistors  
Series/Type:  
C1098, C1084, C1172, B59173, B59184, B59183  
The following products presented in this data sheet are being withdrawn.  
Ordering Code  
Substitute Product  
Date of  
Withdrawal  
Deadline Last Last  
Orders  
Shipments  
B59172C1130A151  
B59098C1100B051  
B59084C1080B140  
2019-03-01  
2019-03-01  
2019-03-01  
2019-06-07  
2019-06-07  
2019-06-07  
2019-09-07  
2019-09-07  
2019-09-07  
Ordering Code  
Substitute Product  
Date of  
Withdrawal  
Deadline Last Last  
Orders  
Shipments  
B59173C1130A151  
B59184C1120B153  
B59183C1160A140  
2021-02-19  
2021-02-19  
2021-02-19  
2021-05-28  
2021-05-28  
2021-05-28  
2021-08-27  
2021-08-27  
2021-08-27  
Please contact your nearest TDK sales office if you need support in selecting a suitable  
substitute. The addresses of our worldwide sales network are presented at www.tdk-  
electronics.tdk.com/sales.  
Overcurrent protection for telecom  
Leaded disks  
Applications  
Overcurrent protection for telecom applications  
Suitable for line card applications e.g. POTS, access networks,  
customer premises equipment (CPE) or integrated voice data (IVD)  
Features  
Compliant with ITU-T standards  
basic-level lightning surges (10/700 µs)  
basic-level power induction (600 V, 1 A, 0.2 s)  
power contact criteria A/B (230 V, 15 min.)  
Matching available with narrow resistance tolerance  
Tight resistance matching maintained after switching  
Negligible resistance drift after soldering or switching  
Marking: Type, manufacturer's logo, reference temperature in °C and date code YYWW  
UL approval to UL 1434 (file number E69802) for B59154U1135B140, B59184C1120B153 and  
B59184C1130A151  
RoHS-compatible  
Options  
Alternative tolerances and resistances on request  
Delivery mode  
Taped on reel: Cardboard tape, 360-mm reel, taping to IEC 60286-2  
Bulk: In plastic bags  
General technical data  
Maximum fault voltage1)  
Max. operating voltage  
Operating temperature range  
Operating temperature range  
VF,max  
Vmax  
Top  
245  
135  
V AC  
V AC  
(V = 0)  
(V = Vmax  
20/+125 °C  
0/+70 °C  
)
Top  
1) The maximum fault voltage VF,max is the highest voltage that is permitted to be applied across the PTC thermistor in protection mode.  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 2 of 13  
Overcurrent protection for telecom  
Leaded disks  
Electrical specifications and ordering codes  
RR  
RR  
R25,match  
IR  
IR  
IS  
ISmax  
Type  
Ordering code  
(per packing unit) @  
@
@
R1R2max  
25°C 70°C 25°C  
mA mA mA  
185 110 440 3.0  
%
A
C1098  
C1084 20.8 ±20  
6
±17  
No  
1
1
B59098C1100B051  
B59084C1080B140  
B59154U1135B140  
B59172C1130A151  
B59184C1120B153  
B59184C1130A151  
B59173C1130A151  
B59183C1160A140  
80  
65  
40 240 3.0  
45 150 2.5  
63 250 2.0  
60 190 2.5  
60 210 2.5  
60 210 2.5  
90 270 3.0  
U1154 50  
C1172 50  
C1184 50  
C1184 50  
C1173 55  
C1183 55  
±15  
±15  
±15  
±15  
±15  
±15  
3
95  
90  
1.0  
1.0  
3.0  
3
100  
90  
115  
Switching times and ordering codes  
RR  
tS (typ.)  
@ ISmax  
s
tS (typ.)  
@ 1 A  
s
tS (typ.)  
@ 500 mA  
s
Type  
Ordering code  
C1098  
C1084  
U1154  
C1172  
C1184  
C1184  
C1173  
C1183  
6
1.5  
14.0  
0.5  
0.3  
1.7  
0.8  
1.1  
1.3  
2.3  
70.0  
2.0  
1.1  
6.0  
3.1  
4.0  
5.0  
9.0  
B59098C1100B051  
B59084C1080B140  
B59154U1135B140  
B59172C1130A151  
B59184C1120B153  
B59184C1130A151  
B59173C1130A151  
B59183C1160A140  
20.8 0.06  
50  
50  
50  
50  
55  
55  
0.05  
0.25  
0.06  
0.08  
0.09  
0.25  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 3 of 13  
Overcurrent protection for telecom  
Leaded disks  
Dimensional drawings 1)  
Figure 1  
Figure 2  
1) The lead length stated in the dimensional drawing refers to the untaped version. For dimensions of the taped version, see chapter  
"Taping and packing".  
Dimensions in mm  
RR  
wmax  
mm  
hmax  
mm  
thmax  
mm  
Type  
Figure  
Packaging  
Ordering code  
C1098  
C1084  
U1154  
C1172  
C1184  
C1184  
C1173  
C1183  
6
13.0  
7.5  
6.0  
8.0  
9.0  
9.0  
8.0  
9.5  
17.0  
4.0  
5.0  
10.5  
4.0  
5.5  
4.5  
4.5  
5.5  
6.0  
Figure 1  
Figure 2  
Figure 2  
Figure 1  
Figure 1  
Figure 1  
Figure 1  
Figure 2  
Taped on reel  
Bulk  
Bulk  
Taped on reel  
Taped on reel  
Taped on reel  
Taped on reel  
Bulk  
B59098C1100B051  
B59084C1080B140  
B59154U1135B140  
B59172C1130A151  
B59184C1120B153  
B59184C1130A151  
B59173C1130A151  
B59183C1160A140  
20.8  
50  
50  
50  
50  
55  
55  
10.0  
11.0  
12.5  
13.0  
11.0  
13.0  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 4 of 13  
Overcurrent protection for telecom  
Leaded disks  
Reliability data  
Test  
Standard  
Test conditions  
R25/R25ꢁ  
Electrical endurance, IEC 60738-1  
cycling  
Room temperature, ISmax; Vmax  
Number of cycles: 10  
< 20%  
Electrical endurance, IEC 60738-1  
constant  
Storage at Vmax and Top,max (@ Vmax  
Test duration: 1000 h  
)
< 25%  
< 10%  
Damp heat  
IEC 60738-1  
IEC 60738-1  
IEC 60738-1  
Temperature of air: 40 °C  
Relative humidity of air: 93%  
Duration: 56 days  
Test according to IEC 60068-2-78  
Rapid change  
of temperature  
T1 = Top,min (0 V), T2 = Top,max (0 V)  
Number of cycles: 5  
Test duration: 30 min  
< 10%  
< 5%  
Test according to IEC 60068-2-14, test Na  
Vibration  
Frequency range: 10 to 55 Hz  
Displacement amplitude: 0.75 mm  
Test duration: 3 × 2 h  
Test according to IEC 60068-2-6, test Fc  
Shock  
IEC 60738-1  
IEC 60738-1  
Acceleration: 400 m/s2  
Pulse duration: 6 ms; 6 × 5000 pulses  
< 5%  
Climatic sequence  
Dry heat: T = Top,max (0 V)  
Test duration: 16 h  
< 10%  
Damp heat first cycle  
Cold: T = Top,min (0 V)  
Test duration: 2 h  
Damp heat 5 cycles  
Tests performed according to  
IEC 60068-2-30  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 5 of 13  
Overcurrent protection for telecom  
Leaded disks  
ITU performance overview and fault conditions  
ITU K20  
Test  
ITU K21  
Enhanced Basic  
ITU K45  
Enhanced Basic  
Basic  
Enhanced  
no.  
test level test level test level test level test level test level  
1
2
3
4
5
A
B
D
F
A
C
E
G
H
A
B
D
G
H
A
C
E
G
I
A
B
D
G
H
A
C
E
G
H
Power induction  
Power contact  
Lightning surge  
H
A
B
C
D
600 V AC, R = 600 , t = 0.2 s, criteria A  
Power induction  
Power contact  
600 V AC, R = 600 , t = 1.0 s, with GDT, criteria A  
1500 V AC, R = 200 , t = 2.0 s, with GDT, criteria A  
230 V AC, t = 15 min, R = 10 ... 1000 , criteria B  
230 V AC, t = 15 min, R = 10, 20, 40, 80, 1000 , criteria B,  
R = 160, 300, 600 , criteria A  
E
F
G
H
I
Vc(max) = 1.0 kV, R = 25 , t = 10/700 µs, without GDT, criteria A  
Vc(max) = 1.5 kV, R = 25 , t = 10/700 µs, without GDT, criteria A  
Vc(max) = 4.0 kV, R = 25 , t = 10/700 µs, with GDT, criteria A  
Vc(max) = 6.0 kV, R = 25 , t = 10/700 µs, with GDT, criteria A  
Lightning surge  
Note: Use a GDT (gas discharge tube) with adequate electrical properties in order to  
ensure reliable operation at enhanced test levels (power induction, lightning surge).  
Criteria A: no damage, function must be fulfilled.  
Criteria B: no fire hazard.  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 6 of 13  
Overcurrent protection for telecom  
Leaded disks  
Additional tests and test conditions  
For type C1172:  
Enhanced test condition to K.20  
power induction  
600 VAC, R = 600 , t = 0.5 s, without GDT, criteria A  
(no damage, function must be fulfilled)  
Enhanced test condition to K.20  
single port, lightning  
Vc(max) = 2500 V, t = 1.2/50 µs, R = 2 , without GDT,  
criteria A (no damage, function must be fulfilled)  
Number of cycles: 500  
For type C1173:  
Enhanced test condition to K.20  
power induction  
600 VAC, R = 600 , t = 0.5 s, without GDT, criteria A  
(no damage, function must be fulfilled)  
Enhanced test condition to K.20  
single port, lightning  
Vc(max) = 4 kV, t = 10/700 µs, R = 40 , without GDT,  
criteria A (no damage, function must be fulfilled)  
For type C1183:  
GR1089  
Second level intra building AC  
power fault  
120 VAC (50 Hz), short circuit current 25 A, t = 15 min,  
criteria A (no damage, function must be fulfilled)  
Enhanced test condition to K.20  
power induction  
600 VAC, R = 600 , t = 1 s, without GDT, criteria A  
(no damage, function must be fulfilled)  
Enhanced test condition to K.20  
single port, lightning  
Vc(max) = 4 kV, t = 10/700 µs, R = 40 , without GDT,  
criteria A (no damage, function must be fulfilled)  
For type C1184:  
Enhanced test condition to K.20  
power induction  
600 VAC, R = 600 , t = 0.5 s, without GDT, criteria A  
(no damage, function must be fulfilled)  
Enhanced test condition to K.20  
power contact  
230 VAC, t = 15 min., R = 10 ... 1000 , criteria A  
(no damage, function must be fulfilled)  
For type U1154:  
GR1089  
Second level intra building AC  
power fault  
120 VAC (50 Hz), short circuit current 25 A, t = 15 min,  
criteria A (no damage, function must be fulfilled)  
Enhanced test condition to GR1089 Vc(max) = ±2.25 kV (each polarity 1 application), t = 2/10 µs,  
first level intra building lightning  
surge for multi-pair ports  
RG = 2 , R = 12 , criteria A  
(no damage, function must be fulfilled)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 7 of 13  
Overcurrent protection for telecom  
Leaded disks  
Cautions and warnings  
General  
EPCOS thermistors are designed for specific applications and should not be used for purposes  
not identified in our specifications, application notes and data books unless otherwise agreed  
with EPCOS during the design-in-phase.  
Ensure suitability of thermistor through reliability testing during the design-in phase. The ther-  
mistors should be evaluated taking into consideration worst-case conditions.  
Storage  
Store thermistors only in original packaging. Do not open the package prior to processing.  
Storage conditions in original packaging: storage temperature 25 °C ... +45 °C, relative hu-  
midity 75% annual mean, maximum 95%, dew precipitation is inadmissible.  
Avoid contamination of thermistors surface during storage, handling and processing.  
Avoid storage of thermistor in harmful environment with effect on function on long-term opera-  
tion (examples given under operation precautions).  
Use thermistor within the following period after delivery:  
Through-hole devices (housed and leaded PTCs): 24 months  
Motor protection sensors, glass-encapsulated sensors and probe assemblies: 24 months  
Telecom pair and quattro protectors (TPP, TQP): 24 months  
Leadless PTC thermistors for pressure contacting: 12 months  
Leadless PTC thermistors for soldering: 6 months  
SMDs in EIA sizes 3225 and 4032, and for PTCs with metal tags: 24 months  
SMDs in EIA sizes 1210 and smaller: 12 months  
Handling  
PTCs must not be dropped. Chip-offs must not be caused during handling of PTCs.  
The ceramic and metallization of the components must not be touched with bare hands. Gloves  
are recommended.  
Avoid contamination of thermistor surface during handling.  
Soldering (where applicable)  
Use rosin-type flux or non-activated flux.  
Insufficient preheating may cause ceramic cracks.  
Rapid cooling by dipping in solvent is not recommended.  
Complete removal of flux is recommended.  
Standard PTC heaters are not suitable for soldering.  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 8 of 13  
Overcurrent protection for telecom  
Leaded disks  
Mounting  
Electrode must not be scratched before/during/after the mounting process.  
Contacts and housing used for assembly with thermistor have to be clean before mounting. Es-  
pecially grease or oil must be removed.  
When PTC thermistors are encapsulated with sealing material, the precautions given in chapter  
"Mounting instructions", "Sealing and potting" must be observed.  
When the thermistor is mounted, there must not be any foreign body between the electrode of  
the thermistor and the clamping contact.  
The minimum force and pressure of the clamping contacts pressing against the PTC must be  
10 N and 50 kPa, respectively. In case the assembly is exposed to mechanical shock and/ or  
vibration this force should be higher in order to avoid movement of the PTC during operation.  
During operation, the thermistor’s surface temperature can be very high. Ensure that adjacent  
components are placed at a sufficient distance from the thermistor to allow for proper cooling at  
the thermistors.  
Ensure that adjacent materials are designed for operation at temperatures comparable to the  
surface temperature of thermistor. Be sure that surrounding parts and materials can withstand  
this temperature.  
Avoid contamination of thermistor surface during processing.  
Operation  
Use thermistors only within the specified temperature operating range.  
Use thermistors only within the specified voltage and current ranges.  
Environmental conditions must not harm the thermistors. Use thermistors only in normal at-  
mospheric conditions. Avoid use in deoxidizing gases (chlorine gas, hydrogen sulfide gas, am-  
monia gas, sulfuric acid gas etc), corrosive agents, humid or salty conditions. Contact with any  
liquids and solvents should be prevented.  
Be sure to provide an appropriate fail-safe function to prevent secondary product damage  
caused by abnormal function (e.g. use VDR for limitation of overvoltage condition).  
This listing does not claim to be complete, but merely reflects the experience of EPCOS AG.  
Display of ordering codes for EPCOS products  
The ordering code for one and the same EPCOS product can be represented differently in data  
sheets, data books, other publications, on the EPCOS website, or in order-related documents  
such as shipping notes, order confirmations and product labels. The varying representations of  
the ordering codes are due to different processes employed and do not affect the  
specifications of the respective products. Detailed information can be found on the Internet  
under www.epcos.com/orderingcodes  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 9 of 13  
Overcurrent protection for telecom  
Leaded disks  
Symbols and terms  
Symbol  
A
Term  
Area  
C
Capacitance  
Cth  
f
Heat capacity  
Frequency  
I
Current  
Imax  
IR  
Maximum current  
Rated current  
Ires  
Residual current  
IPTC  
Ir  
PTC current  
Residual currrent  
Ir,oil  
Ir,air  
IRMS  
IS  
Residual currrent in oil (for level sensors)  
Residual currrent in air (for level sensors)  
Root-mean-square value of current  
Switching current  
ISmax  
LCT  
N
Maximum switching current  
Lower category temperature  
Number (integer)  
Nc  
Operating cycles at Vmax, charging of capacitor  
Switching cycles at Vmax, failure mode  
Power  
Nf  
P
P25  
Pel  
Maximum power at 25 °C  
Electrical power  
Pdiss  
RG  
Rmin  
RR  
Dissipation power  
Generator internal resistance  
Minimum resistance  
Rated resistance @ rated temperature TR  
Tolerance of RR  
RR  
RP  
Parallel resistance  
RPTC  
Rref  
RS  
PTC resistance  
Reference resistance  
Series resistance  
R25  
R25,match  
R25  
Resistance at 25 °C  
Resistance matching per reel/ packing unit at 25 °C  
Tolerance of R25  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 10 of 13  
Overcurrent protection for telecom  
Leaded disks  
T
Temperature  
t
Time  
TA  
Ambient temperature  
ta  
Thermal threshold time  
TC  
Ferroelectric Curie temperature  
Settling time (for level sensors)  
Rated temperature @ 25 °C or otherwise specified in the data sheet  
Sensing temperature  
tE  
TR  
Tsense  
Top  
Operating temperature  
TPTC  
tR  
PTC temperature  
Response time  
Tref  
Reference temperature  
TRmin  
tS  
Temperature at minimum resistance  
Switching time  
Tsurf  
UCT  
V or Vel  
Vc(max)  
VF,max  
VRMS  
VBD  
Vins  
Vlink,max  
Vmax  
Vmax,dyn  
Vmeas  
Vmeas,max  
VR  
Surface temperature  
Upper category temperature  
Voltage (with subscript only for distinction from volume)  
Maximum DC charge voltage of the surge generator  
Maximum voltage applied at fault conditions in protection mode  
Root-mean-square value of voltage  
Breakdown voltage  
Insulation test voltage  
Maximum link voltage  
Maximum operating voltage  
Maximum dynamic (short-time) operating voltage  
Measuring voltage  
Maximum measuring voltage  
Rated voltage  
VPTC  
α
Voltage drop across a PTC thermistor  
Temperature coefficient  
Tolerance, change  
δth  
Dissipation factor  
τth  
Thermal cooling time constant  
Failure rate  
λ
Lead spacing (in mm)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 11 of 13  
Important notes  
The following applies to all products named in this publication:  
1. Some parts of this publication contain statements about the suitability of our products for  
certain areas of application. These statements are based on our knowledge of typical  
requirements that are often placed on our products in the areas of application concerned. We  
nevertheless expressly point out that such statements cannot be regarded as binding  
statements about the suitability of our products for a particular customer application. As a  
rule we are either unfamiliar with individual customer applications or less familiar with them than  
the customers themselves. For these reasons, it is always ultimately incumbent on the customer  
to check and decide whether a product with the properties described in the product specification is  
suitable for use in a particular customer application.  
2. We also point out that in individual cases, a malfunction of electronic components or failure  
before the end of their usual service life cannot be completely ruled out in the current state  
of the art, even if they are operated as specified. In customer applications requiring a very high  
level of operational safety and especially in customer applications in which the malfunction or  
failure of an electronic component could endanger human life or health (e.g. in accident  
prevention or life-saving systems), it must therefore be ensured by means of suitable design of the  
customer application or other action taken by the customer (e.g. installation of protective circuitry  
or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or  
failure of an electronic component.  
3. The warnings, cautions and product-specific notes must be observed.  
4. In order to satisfy certain technical requirements, some of the products described in this  
publication may contain substances subject to restrictions in certain jurisdictions (e.g.  
because they are classed as hazardous). Useful information on this will be found in our Material  
Data Sheets on the Internet (www.tdk-electronics.tdk.com/material). Should you have any more  
detailed questions, please contact our sales offices.  
5. We constantly strive to improve our products. Consequently, the products described in this  
publication may change from time to time. The same is true of the corresponding product  
specifications. Please check therefore to what extent product descriptions and specifications  
contained in this publication are still applicable before or when you place an order.  
We also reserve the right to discontinue production and delivery of products. Consequently,  
we cannot guarantee that all products named in this publication will always be available.  
The aforementioned does not apply in the case of individual agreements deviating from the  
foregoing for customer-specific products.  
6. Unless otherwise agreed in individual contracts, all orders are subject to our General Terms  
and Conditions of Supply.  
7. Our manufacturing sites serving the automotive business apply the IATF 16949 standard.  
The IATF certifications confirm our compliance with requirements regarding the quality  
management system in the automotive industry. Referring to customer requirements and  
customer specific requirements (“CSR”) TDK always has and will continue to have the policy of  
respecting individual agreements. Even if IATF 16949 may appear to support the acceptance of  
unilateral requirements, we hereby like to emphasize that only requirements mutually agreed  
upon can and will be implemented in our Quality Management System. For clarification  
purposes we like to point out that obligations from IATF 16949 shall only become legally binding if  
individually agreed upon.  
Page 12 of 13  
Important notes  
8. The trade names EPCOS, CeraCharge, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CTVS,  
DeltaCap, DigiSiMic, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD, MKK,  
MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PowerHap, PQSine, PQvar,  
SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, ThermoFuse,  
WindCap are trademarks registered or pending in Europe and in other countries. Further  
information will be found on the Internet at www.tdk-electronics.tdk.com/trademarks.  
Release 2018-10  
Page 13 of 13  

相关型号:

B59154U1135B151

RESISTOR, TEMPERATURE DEPENDENT, PTC, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT
EPCOS

B59155-M100-A70

RESISTOR, TEMPERATURE DEPENDENT, PTC, 100ohm, THROUGH HOLE MOUNT
EPCOS

B59155-M110-A70

RESISTOR, TEMPERATURE DEPENDENT, PTC, 100ohm, THROUGH HOLE MOUNT
EPCOS

B59155-M120-A70

RESISTOR, TEMPERATURE DEPENDENT, PTC, 100ohm, THROUGH HOLE MOUNT
EPCOS

B59155-M130-A70

RESISTOR, TEMPERATURE DEPENDENT, PTC, 100ohm, THROUGH HOLE MOUNT
EPCOS

B59155-M140-A70

RESISTOR, TEMPERATURE DEPENDENT, PTC, 100ohm, THROUGH HOLE MOUNT
EPCOS

B59155-M145-A70

RESISTOR, TEMPERATURE DEPENDENT, PTC, 100ohm, THROUGH HOLE MOUNT
EPCOS

B59155-M150-A70

RESISTOR, TEMPERATURE DEPENDENT, PTC, 100ohm, THROUGH HOLE MOUNT
EPCOS

B59155-M155-A70

RESISTOR, TEMPERATURE DEPENDENT, PTC, 100ohm, THROUGH HOLE MOUNT
EPCOS

B59155-M170-A70

RESISTOR, TEMPERATURE DEPENDENT, PTC, 100ohm, THROUGH HOLE MOUNT
EPCOS

B59155-M180-A70

RESISTOR, TEMPERATURE DEPENDENT, PTC, 100ohm, THROUGH HOLE MOUNT
EPCOS

B59155-M60-A70

RESISTOR, TEMPERATURE DEPENDENT, PTC, 100ohm, THROUGH HOLE MOUNT
EPCOS