B88069X8061T602 [TDK]

Switching spark gap;
B88069X8061T602
型号: B88069X8061T602
厂家: TDK ELECTRONICS    TDK ELECTRONICS
描述:

Switching spark gap

文件: 总5页 (文件大小:128K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Switching spark gap  
SSG without lead wires  
Series/Type:  
FS08HF1BSMD  
Ordering code:  
B88069X7391T602  
Version/Date:  
Issue 03 / 2008-11-05  
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the  
table and then change the color to "white" (or invisible). This ensures that the table disappears for the customer  
PDF. To update the data sheet, click on the symbol "Preview" and then "Close". Please do not alter the header or  
footer when copying the content.  
Identification/Classification 1:  
(header 1 + top left header bar)  
Switching spark gap  
SSG without lead wires  
B88069X7391T602  
FS08HF1BSMD  
Identification/Classification 2:  
(header 2 + bottom left header bar)  
Ordering code:  
(top right header bar)  
Series/Type:  
(top right header bar)  
EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information  
Preliminary data (optional):  
contained therein without EPCOS' prior express consent is prohibited.  
(if necessary)  
Department:  
KB AB E / KB AB PM  
Issue 03 / 2008-11-05  
EPCOS AG is a TDK Group Company.  
Date:  
Switching spark gap  
B88069X7391T602  
FS08HF1BSMD  
SSG without lead wires  
Features  
Applications  
. Ignition of HID lamps  
.
.
.
Extremely long life time  
Stable performance over life  
Insensitive performance against variations in  
temperature  
.
.
.
.
.
Very low switching losses  
Very short breakdown time  
High reliability by robust design  
Excellent SMD handling  
RoHS compatible  
Electrical specifications  
Nominal breakdown voltage Vn  
800  
V
Initial values 2)  
1)  
Static breakdown voltage Vs  
First ignition value Vs, fte after 24 hours in darkness  
Following ignition values Vs, fiv  
950  
704 ... 896  
V
V
Electrical life time 3)  
Breakdown voltage Vb  
First ignition value VB, FTE after 24 hours in darkness  
V
ms  
V
1000  
60  
680 ... 920  
Ignition time tI at V0 during life  
Following ignition values VB, FIV  
Switching operations  
at –40 °C  
at +25; 125; 150 °C  
40 000  
200 000  
Ignitions  
Ignitions  
Test circuit parameters  
Open circuit voltage Vo  
Loading resistance R  
Discharge capacitance C  
Inductance L  
1000  
68  
100  
0.4  
V
k  
nF  
µH  
A
650  
Discharge peak current Ip  
General technical data  
Insulation resistance at 100 V  
Early ignition values below 704 V  
Breakdown time  
> 100  
1  
50  
200  
50  
M  
%
ns  
Hz  
mA  
g
Maximum switching frequency  
Maximum loading current  
Weight  
~ 2  
300  
Storage at +170 °C  
h
KB AB E / KB AB PM  
Issue 03 / 2008-11-05  
Please read Cautions and warnings and  
Page 2 of 5  
Important notes at the end of this document.  
Switching spark gap  
B88069X7391T602  
FS08HF1BSMD  
SSG without lead wires  
Marking, green positive  
800 WWY O  
800  
WW  
Y
- Nominal voltage  
- Calendar week of production  
- Year of production  
O
- Non radioactive  
1)  
At delivery AQL 0,65 level II, DIN ISO 2859  
Page 2, Fig. 1 and 2  
Page 2, Fig. 3 and 4  
2)  
3)  
Figures  
Fig. 1: QC- test circuit (100% outgoing inspection)  
Fig. 2: Explanation of measurands  
I = const  
51k  
VS, FTE  
VS, FIV  
VS  
DUT  
VN  
VS  
0,22 F  
ICU  
- VN  
DUT device under test  
ICU ignition control unit (sensitivity 10 ... 30 A)  
Discharge current 10 ... 20 mA  
dVS/dt ~ dVN/dt  
Fig. 4: Explanation of measurands  
Fig. 3: QC- test circuit (sampling inspection at 25 °C)  
VB, FTE  
VB, FTE  
L
R
Range of VB, FIV  
Early ignition  
VB  
VN  
VB  
VO  
DUT  
C
t
tI  
10 s  
1 s  
KB AB E / KB AB PM  
Issue 03 / 2008-11-05  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 3 of 5  
Switching spark gap  
B88069X7391T602  
FS08HF1BSMD  
SSG without lead wires  
Dimensional drawing in mm  
Ordering code and packing advice  
B88069X7391T602 = 600 pcs. on SMD-tape  
Cautions and warnings  
.
.
Switching spark gaps may be used only within their specified values.  
Damaged switching spark gaps must not be re-used.  
KB AB E / KB AB PM  
Issue 03 / 2008-11-05  
Please read Cautions and warnings and  
Page 4 of 5  
Important notes at the end of this document.  
Important notes  
The following applies to all products named in this publication:  
1. Some parts of this publication contain statements about the suitability of our products for  
certain areas of application. These statements are based on our knowledge of typical  
requirements that are often placed on our products in the areas of application concerned. We  
nevertheless expressly point out that such statements cannot be regarded as binding  
statements about the suitability of our products for a particular customer application. As a  
rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them  
than the customers themselves. For these reasons, it is always ultimately incumbent on the  
customer to check and decide whether an EPCOS product with the properties described in the  
product specification is suitable for use in a particular customer application.  
2. We also point out that in individual cases, a malfunction of electronic components or failure  
before the end of their usual service life cannot be completely ruled out in the current state  
of the art, even if they are operated as specified. In customer applications requiring a very high  
level of operational safety and especially in customer applications in which the malfunction or  
failure of an electronic component could endanger human life or health (e.g. in accident  
prevention or life-saving systems), it must therefore be ensured by means of suitable design of the  
customer application or other action taken by the customer (e.g. installation of protective circuitry  
or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or  
failure of an electronic component.  
3. The warnings, cautions and product-specific notes must be observed.  
4. In order to satisfy certain technical requirements, some of the products described in this  
publication may contain substances subject to restrictions in certain jurisdictions (e.g.  
because they are classed as hazardous). Useful information on this will be found in our Material  
Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed  
questions, please contact our sales offices.  
5. We constantly strive to improve our products. Consequently, the products described in this  
publication may change from time to time. The same is true of the corresponding product  
specifications. Please check therefore to what extent product descriptions and specifications  
contained in this publication are still applicable before or when you place an order.  
We also reserve the right to discontinue production and delivery of products. Consequently,  
we cannot guarantee that all products named in this publication will always be available.  
The aforementioned does not apply in the case of individual agreements deviating from the  
foregoing for customer-specific products.  
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of  
the “General Terms of Delivery for Products and Services in the Electrical Industry”  
published by the German Electrical and Electronics Industry Association (ZVEI).  
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, CTVS, DSSP, MiniBlue, MKK,  
MLSC, MotorCap, PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD,  
SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or  
pending in Europe and in other countries. Further information will be found on the Internet at  
www.epcos.com/trademarks.  
Page 5 of 5  

相关型号:

B88069X8070B502

SURGE ARRESTER 3-electrode arrester
EPCOS

B88069X8080B502

SURGE ARRESTER 2-electrode arrester
EPCOS

B88069X810S102

GAS DISCHARGE TUBE 350V
ETC

B88069X8160B502

SURGE ARRESTER 3-electrode arrester
EPCOS

B88069X8190B502

SURGE ARRESTER 3-electrode arrester
EPCOS

B88069X8220B502

SURGE ARRESTER 3-electrode arrester
EPCOS

B88069X8250B502

SURGE ARRESTER 3-electrode arrester
EPCOS

B88069X8300B502

SURGE ARRESTER 3-electrode arrester
EPCOS

B88069X8340B502

SURGE ARRESTER 3-electrode arrester
EPCOS

B88069X8350B502

SURGE ARRESTER 3-electrode arrester
EPCOS

B88069X8360C203

SURGE ARRESTER 3-electrode arrester
EPCOS

B88069X8380B502

SURGE ARRESTER 3-electrode arrester
EPCOS