Insulation type DC-DC converter 绝缘型DC-DC转换器 DC/DC转换器 电源模块
CC3-0503SR-E 规格参数
是否Rohs认证: | 符合 | 生命周期: | Active |
包装说明: | SMD-7 | Reach Compliance Code: | compliant |
ECCN代码: | EAR99 | 风险等级: | 2.27 |
Is Samacsys: | N | 模拟集成电路 - 其他类型: | DC-DC REGULATED POWER SUPPLY MODULE |
最大输入电压: | 9 V | 最小输入电压: | 4.5 V |
标称输入电压: | 5 V | JESD-30 代码: | R-MDMA-G7 |
长度: | 22.86 mm | 功能数量: | 1 |
输出次数: | 1 | 端子数量: | 7 |
最高工作温度: | 50 °C | 最低工作温度: | -40 °C |
最大输出电压: | 3.6 V | 最小输出电压: | 3.15 V |
标称输出电压: | 3.3 V | 封装主体材料: | METAL |
封装形状: | RECTANGULAR | 封装形式: | MICROELECTRONIC ASSEMBLY |
峰值回流温度(摄氏度): | NOT SPECIFIED | 座面最大高度: | 8.8 mm |
表面贴装: | YES | 技术: | HYBRID |
温度等级: | OTHER | 端子形式: | GULL WING |
端子位置: | DUAL | 处于峰值回流温度下的最长时间: | NOT SPECIFIED |
最大总功率输出: | 3 W | 微调/可调输出: | YES |
宽度: | 16.6 mm | Base Number Matches: | 1 |
CC3-0503SR-E 数据手册
通过下载CC3-0503SR-E数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载ꢀ
InsulationꢀtypeꢀDC-DCꢀconverter
CC-E
Y
E
A
R
5
S
EN60950-1
warranty
ow Voltage Directive
UL60950-1/
L
CSA C22.2 No.60950-1
■ Features
■ Model-naming method
●Mounting area halved compared to existing products
●Nonuse of tantalum capacitor or aluminum electro-
lytic capacitor
●Remote On/Off function incorporated in all series of
products
ꢀ ꢀCCꢀ3ꢀ-ꢀ05ꢀ05ꢀSꢀFꢀ-E
F: Horizontally-mounted DIP type
R: Horizontally-mounted SMD type
FS Vertically-mounted SIP type
Shape
Symbol for number of outputs
S: Single output, D: Dual outputs
Nominal output voltage
03: 3.3V, 05: 5V, 12: 12V
●High accuracy of ±3% in output voltage (10W of
lower single output)
Nominal input voltage
05: 5V, 12: 12V, 24: 24V, 48: 48V
●5-side metal-shielded low noise design
●Lightweight design with no resin filled up
●Supports DIP insertion,SMD mounting and SIP verti-
cal insertion (3W products)
Maximum output power
1R5: 1.5W, 3: 3W, 6:6W
10: 10W, 15: 15W, 25: 25W
Representing series name by
combination with "-E"at the end
●Approved by UL60950-1, CSA C22.2 No.60950-1
(C-UL), and EN60950-1 (NEMKO)
■
Conformity to RoHS Directive
■ Applications
This means that, in conformity with EU Directive
2002/95/EC, lead, cadmium, mercury, hexavalent
chromium, and specific bromine-based flame retar-
dants, PBB and PBDE, have not been used, except for
exempted applications.
■ Product Line up
Model name
Model name
Model name
Model name
Output
power
Input
(output voltage: 3.3V)
(output voltage: 5V)
(output voltage: 12V/15V)
(output voltage: ±12V/±15V)
voltage
Output current
DIP type
SMD type
SIP type Output current
DIP type
SMD type
SIP type Output current
DIP type
SMD type
SIP type Output current
DIP type
SMD type
SIP type
5V
0.4A CC1R5-0503SF-E CC1R5-0503SR-E
-
-
-
-
0.3A CC1R5-0505SF-E CC1R5-0505SR-E
0.3A CC1R5-1205SF-E CC1R5-1205SR-E
0.3A CC1R5-2405SF-E CC1R5-2405SR-E
0.3A CC1R5-4805SF-E CC1R5-4805SR-E
-
-
-
-
0.125A (0.1A) CC1R5-0512SF-E CC1R5-0512SR-E
0.125A (0.1A) CC1R5-1212SF-E CC1R5-1212SR-E
0.125A (0.1A) CC1R5-2412SF-E CC1R5-2412SR-E
0.125A (0.1A) CC1R5-4812SF-E CC1R5-4812SR-E
-
-
-
-
0.06A (0.05A) CC1R5-0512DF-E CC1R5-0512DR-E
0.06A (0.05A) CC1R5-1212DF-E CC1R5-1212DR-E
0.06A (0.05A) CC1R5-2412DF-E CC1R5-2412DR-E
0.06A (0.05A) CC1R5-4812DF-E CC1R5-4812DR-E
-
12V 0.4A CC1R5-1203SF-E CC1R5-1203SR-E
24V 0.4A CC1R5-2403SF-E CC1R5-2403SR-E
48V 0.4A CC1R5-4803SF-E CC1R5-4803SR-E
-
1.5W
3W
-
-
5V
0.8A CC3-0503SF-E
CC3-0503SR-E CC3-0503SS-E 0.6A
CC3-1203SR-E CC3-1203SS-E 0.6A
CC3-2403SR-E CC3-2403SS-E 0.6A
CC3-4803SR-E CC3-4803SS-E 0.6A
CC3-0505SF-E
CC3-1205SF-E
CC3-2405SF-E
CC3-4805SF-E
CC6-0505SF-E
CC6-1205SF-E
CC6-2405SF-E
CC6-4805SF-E
CC10-0505SF-E
CC10-1205SF-E
CC10-2405SF-E
CC10-4805SF-E
CC15-2405SF-E
CC25-2405SF-E
CC3-0505SR-E
CC3-1205SR-E
CC3-2405SR-E
CC3-4805SR-E
CC6-0505SR-E
CC6-1205SR-E
CC6-2405SR-E
CC6-4805SR-E
CC10-0505SR-E
CC10-1205SR-E
CC10-2405SR-E
CC10-4805SR-E
CC15-2405SR-E
CC25-2405SR-E
CC3-0505SS-E 0.25A (0.2A)
CC3-1205SS-E 0.25A (0.2A)
CC3-2405SS-E 0.25A (0.2A)
CC3-4805SS-E 0.25A (0.2A)
CC3-0512SF-E
CC3-1212SF-E
CC3-2412SF-E
CC3-4812SF-E
CC6-0512SF-E
CC6-1212SF-E
CC6-2412SF-E
CC6-4812SF-E
CC3-0512SR-E
CC3-1212SR-E
CC3-2412SR-E
CC3-4812SR-E
CC6-0512SR-E
CC6-1212SR-E
CC6-2412SR-E
CC6-4812SR-E
CC10-0512SR-E
CC10-1212SR-E
CC10-2412SR-E
CC10-4812SR-E
-
CC3-0512SS-E 0.125A (0.1A) CC3-0512DF-E
CC3-1212SS-E 0.125A (0.1A) CC3-1212DF-E
CC3-2412SS-E 0.125A (0.1A) CC3-2412DF-E
CC3-4812SS-E 0.125A (0.1A) CC3-4812DF-E
CC3-0512DR-E
CC3-1212DR-E
CC3-2412DR-E
CC3-4812DR-E
CC6-0512DR-E
CC6-1212DR-E
CC6-2412DR-E
CC6-4812DR-E
CC10-0512DR-E
CC10-1212DR-E
CC10-2412DR-E
CC10-4812DR-E
-
CC3-0512DS-E
12V 0.8A CC3-1203SF-E
24V 0.8A CC3-2403SF-E
48V 0.8A CC3-4803SF-E
CC3-1212DS-E
CC3-2412DS-E
CC3-4812DS-E
5V
1.2A CC6-0503SF-E
CC6-0503SR-E
CC6-1203SR-E
CC6-2403SR-E
CC6-4803SR-E
-
-
-
-
-
-
-
-
-
-
1A
1.2A
1.2A
1.2A
2A
-
-
-
-
-
-
-
-
-
-
0.5A (0.4A)
0.5A (0.4A)
0.5A (0.4A)
0.5A (0.4A)
-
-
-
-
-
-
-
-
-
-
0.25A (0.2A)
0.25A (0.2A)
0.25A (0.2A)
0.25A (0.2A)
CC6-0512DF-E
CC6-1212DF-E
CC6-2412DF-E
CC6-4812DF-E
-
-
-
-
-
-
-
-
-
-
12V 1.2A CC6-1203SF-E
24V 1.2A CC6-2403SF-E
48V 1.2A CC6-4803SF-E
6W
5V
2.5A CC10-0503SF-E CC10-0503SR-E
0.8A (0.64A) CC10-0512SF-E
1A (0.8A) CC10-1212SF-E
1A (0.8A) CC10-2412SF-E
1A (0.8A) CC10-4812SF-E
0.4A (0.32A) CC10-0512DF-E
0.45A (0.36A) CC10-1212DF-E
0.45A (0.36A) CC10-2412DF-E
0.45A (0.36A) CC10-4812DF-E
12V 2.5A CC10-1203SF-E CC10-1203SR-E
24V 2.5A CC10-2403SF-E CC10-2403SR-E
48V 2.5A CC10-4803SF-E CC10-4803SR-E
2A
10W
2A
2A
15W 24V 4.5A CC15-2403SF-E CC15-2403SR-E
25W 24V 7.5A CC25-2403SF-E CC25-2403SR-E
3A
-
-
-
-
-
-
-
-
5A
-
-
00ꢀ-0ꢀ/2008042ꢀ/etl_cc_e
・All specifications are subject to change without notice.
2
CC1R5-E
CC1R5-E Specifications
MODEL
CC1R5-0503Sx-E CC1R5-0505Sx-E
CC1R5-0512Sx-E
CC1R5-0512Dx-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC5.0
DC4.5-9.0
80
Voltage Range
Efficiency (typ)
Input
(*1)
(*1)
%
A
71
0.372
3.3
77
0.390
5
79
0.380
Current (typ)
0.375
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
0.125
15
0.100
1.5
± 12
0.060
± 15
0.050
0.400
1.32
0.300
(*2)
W
Maximum Line Regulation (Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
40
100
80
600
Output
Temperature Coefficient
(Ambient temperature–40°C to +50°C)
80mV
200mV
300mV
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Standards Safety Standards
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Isolation
Weight (typ)
Size (W x H x D)
g
mm
3.2
Mechanical
DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
CC1R5-1203Sx-E CC1R5-1205Sx-E
CC1R5-1212Sx-E
CC1R5-1212Dx-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC12
DC9.0-18
82
Voltage Range
Efficiency (typ)
Current (typ)
Input
(*1)
(*1)
%
A
73
0.151
3.3
78
0.160
5
81
0.154
0.152
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
0.125
15
0.100
1.5
± 12
0.060
± 15
0.050
0.400
1.32
0.300
(*2)
W
Maximum Line Regulation (Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
40
100
80
600
Output
Temperature Coefficient
(Ambient temperature–40°C to +50°C)
80mV
200mV
300mV
Max Power Total Regulation (max)(*4)
%
± 3
ꢀ 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
Available
± 11.4 - ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Standards Safety Standards
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Isolation
Weight (typ)
Size (W x H x D)
g
mm
3.2
Mechanical
DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.
ꢁ
CC1R5-E
MODEL
CC1R5-2403Sx-E CC1R5-2405Sx-E
CC1R5-2412Sx-E
CC1R5-2412Dx-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC24
DC18-36
81
Voltage Range
Efficiency (typ)
Input
(*1)
(*1)
%
A
72
0.076
3.3
77
0.081
5
79
0.079
Current (typ)
0.077
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
0.125
15
0.100
1.5
± 12
0.060
± 15
0.050
0.400
1.32
0.300
(*2)
W
Maximum Line Regulation (Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
40
100
80
600
Output
Temperature Coefficient
(Ambient temperature–40°C to +50°C)
80mV
200mV
300mV
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Standards Safety Standards
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Isolation
Weight (typ)
Size (W x H x D)
g
mm
3.2
Mechanical
DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
CC1R5-4803Sx-E CC1R5-4805Sx-E
CC1R5-4812Sx-E
CC1R5-4812Dx-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC48
DC36-76
80
Voltage Range
Efficiency (typ)
Current (typ)
Input
(*1)
(*1)
%
A
70
0.039
3.3
76
0.041
5
79
0.040
0.039
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
0.125
15
0.100
1.5
± 12
0.060
± 15
0.050
0.400
1.32
0.300
(*2)
W
Maximum Line Regulation (Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
40
100
80
600
Output
Temperature Coefficient
(Ambient temperature–40°C to +50°C)
80mV
200mV
300mV
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Standards Safety Standards
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Isolation
Weight (typ)
Size (W x H x D)
g
mm
3.2
Mechanical
DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.
4
CC1R5-E
Outline Drawing
CC1R5-xxxxxF-Eꢀ(DIPꢀtype)
16.6 0.2
Recommended measurements for
mounting board
Shape/Dimensions
14.605
Outer shape of
product
t=0.3
12.7
7-ø1.0 (land diameter ø2.0)
16.51
1.905
12.7
1.905
2.7
a
b
2-ø1.5 (land diameter ø2.5)
a
3
2
b
4
5
16.51
1.0
7-0.3×0.6
6
7
a
Unit: mm
2.7
1
Allowable tolerance is 0.5 if not specified separately.
b
CC1R5-xxxxxR-Eꢀ(SMDꢀtype)
16.6 0.2
Shape/Dimensions
Recommended measurements for
mounting board
Outer shape of
product
t=0.3
Coplanarity: 0.1 or lower
16.51
19.81
1.8
1.8
3.2
15.6
22.0
3.2
3
2
4
5
7-0.3×0.6
6
7
1
Unit: mm
Allowable tolerance is 0.5 if not specified separately.
Connection diagram
CC1R5-xxxxSx-E
CC1R5-xxxxDx-E
Terminal connections
Terminal connections
No.1 +Vin
+Vin
+Vout
+Vin
+Vout
1
7
6
5
1
7
6
5
No.1 +Vin
No.2 RC
No.2 RC
TRM
TRM
COM
–Vout
No.3 –Vin
No.4 NC
No.3 –Vin
RC
2
–Vout
RC
No.4 –Vout
2
3
No.5 –Vout
No.6 TRM
No.7 +Vout
No.5 Common out
No.6 TRM
4 NC
3
4
–Vin
–Vin
No.7 +Vout
Derating Curve
100
80
60
40
20
0
Natural air cooling
a
b
a:0.5m/s(100LFM)
b:1m/s(200LFM)
-40 -20
ꢀ 0ꢀ 20ꢀ 40ꢀ60ꢀ80ꢀ100
Ambient temperature (°C)
Output power derating by ambient temperature
(common specification)
・All specifications are subject to change without notice.
ꢂ
DIP/SMD
CC3-E(
)
CC3-E Specifications
MODEL
CC3-0503Sx-E
CC3-0505Sx-E
CC3-0512Sx-E
CC3-0512Dx-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC5.0
DC4.5-9.0
82
Voltage Range
Efficiency (typ)
Current (typ)
Input
(*1)
(*1)
%
A
73
0.723
3.3
0.800
2.64
77
0.779
5
81
0.741
0.732
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
0.250
15
0.200
3
± 12
0.125
± 15
0.100
0.600
(*2)
Maximum Line Regulation(Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
40
100
80
600
Output
Temperature Coefficient
(Ambient temperature -40℃ to +50℃ )
80mV
200mV
300mV
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Standards Safety Standards
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Isolation
Weight (typ)
Size (W x H x D)
g
mm
4.5
Mechanical
DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
CC3-1203Sx-E
CC3-1205Sx-E
CC3-1212Sx-E
CC3-1212Dx-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC12
DC9.0-18
82
Voltage Range
Efficiency (typ)
Current (typ)
Input
(*1)
(*1)
%
A
74
0.297
3.3
0.800
2.64
79
0.316
5
81
0.309
0.305
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
0.250
15
0.200
3
± 12
0.125
± 15
0.100
0.600
(*2)
W
Maximum Line Regulation(Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
40
100
80
600
Output
Temperature Coefficient
(Ambient temperature -40℃ to +50℃ )
80mV
200mV
300mV
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Standards Safety Standards
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Isolation
Weight (typ)
Size (W x H x D)
g
mm
4.5
Mechanical
DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.
ꢃ
DIP/SMD
CC3-E(
)
MODEL
CC3-2403Sx-E
CC3-2405Sx-E
CC3-2412Sx-E
CC3-2412Dx-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC24
DC18-36
82
Voltage Range
Efficiency (typ)
Current (typ)
Input
(*1)
(*1)
%
A
73
0.151
3.3
0.800
2.64
78
0.160
5
81
0.154
0.152
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
0.250
15
0.200
3
± 12
0.125
± 15
0.100
0.600
(*2)
W
Maximum Line Regulation(Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
40
100
80
600
Output
Temperature Coefficient
(Ambient temperature -40℃ to +50℃ )
80mV
200mV
300mV
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Standards Safety Standards
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Isolation
Weight (typ)
Size (W x H x D)
g
mm
4.5
Mechanical
DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
CC3-4803Sx-E
CC3-4805Sx-E
CC3-4812Sx-E
CC3-4812Dx-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC48
DC36-76
81
Voltage Range
Efficiency (typ)
Current (typ)
Input
(*1)
(*1)
%
A
73
0.075
3.3
0.800
2.64
79
0.079
5
80
0.078
0.077
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
0.250
15
0.200
3
± 12
0.125
± 15
0.100
0.600
(*2)
W
Maximum Line Regulation(Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
40
100
80
600
Output
Temperature Coefficient
(Ambient temperature -40℃ to +50℃ )
80mV
200mV
300mV
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Standards Safety Standards
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Isolation
Weight (typ)
Size (W x H x D)
g
mm
4.5
Mechanical
DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.
ꢄ
DIP/SMD
CC3-E(
)
Outline Drawing
CC3-xxxxxF-Eꢀ(DIPꢀtype)
16.6 0.2
Shape/Dimensions
Recommended measurements for mounting board
20.32
Outer shape of product
t=0.3
7-ø1.0 (land diameter ø2.0)
17.78
22.86
2.7
2.54
17.78
2.54
a
b
2-ø1.5 (land diameter ø2.5)
22.86
a
3
b
4
1.0
2
5
7-0.3×0.6
6
2.7
1
7
a
Unit: mm
Allowable tolerance is 0.5 if not specified separately.
b
CC3-xxxxxR-Eꢀ(SMDꢀtype)
16.6 0.2
Shape/Dimensions
Recommended measurements for mounting board
Outer shape of product
t=0.3
22.86
Coplanarity: 0.1 or lower
26.16
1.8
1.8
3.2
22.0
28.4
3.2
3
2
4
5
7-0.3×0.6
6
7
1
Unit: mm
Allowable tolerance is 0.5 if not specified separately.
Connection diagram
CC3-xxxxSx-E
CC3-xxxxDx-E
Terminal connections
No.1 +Vin
No.2 RC
No.3 –Vin
No.4 NC
No.5 –Vout
No.6 TRM
No.7 +Vout
Terminal connections
No.1 +Vin
No.2 RC
No.3 –Vin
No.4 –Vout
No.5 Common out
No.6 TRM
+Vin
1
+Vout
TRM
+Vin
1
+Vout
7
6
5
7
6
5
TRM
COM
–Vout
RC
2
RC
2
–Vout
4 NC
4
3
3
–Vin
–Vin
No.7 +Vout
Derating Curve
100
80
60
40
20
0
Natural air cooling
a
b
a:0.5m/s(100LFM)
b:1m/s(200LFM)
-40 -20
ꢀ 0ꢀ 20ꢀ 40ꢀ60ꢀ80ꢀ100
Ambient temperature (°C)
Output power derating by ambient temperature
(common specification)
・All specifications are subject to change without notice.
8
SIP
CC3-E(
)
CC3-E Specifications
MODEL
CC3-0503SS-E
CC3-0505SS-E
CC3-0512SS-E
CC3-0512DS-E
ITEMS/UNITSꢀ
Nominal Voltage
Voltage Range
Efficiency (typ)
Current (typ)
V
V
DC5.0
DC4.5-9.0
82
Input
(*1)
(*1)
%
A
73
0.723
3.3
0.800
2.64
77
0.779
5
81
0.741
0.732
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
0.250
15
0.200
3
± 12
0.125
± 15
0.100
0.600
(*2)
W
Maximum Line Regulation (Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
40
100
80
600
Output
Temperature Coefficient
(Ambient temperature -40℃ to +50℃ )
80mV
200mV
300mV
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.67
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Isolation
Standards Safety Standards
Weight (typ)
Size (W x H x D)
g
mm
7
Mechanical
27.8 x 17.9 x 9.2
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
CC3-1203SS-E
CC3-1205SS-E
CC3-1212SS-E
CC3-1212DS-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC12
DC9.0-18
Voltage Range
Efficiency (typ)
Current (typ)
Input
(*1)
(*1)
%
A
73
0.301
3.3
0.800
2.64
79
0.316
5
82
0.305
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
0.250
15
0.200
3
± 12
0.125
± 15
0.100
0.600
(*2)
W
Maximum Line Regulation (Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
40
100
80
600
Output
Temperature Coefficient
(Ambient temperature -40℃ to +50℃ )
80mV
200mV
300mV
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.67
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Isolation
Standards Safety Standards
Weight (typ)
Size (W x H x D)
g
mm
7
Mechanical
27.8 x 17.9 x 9.2
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.
ꢅ
SIP
CC3-E(
)
MODEL
CC3-2403SS-E
CC3-2405SS-E
CC3-2412SS-E
CC3-2412DS-E
ITEMS/UNITSꢀ
Nominal Voltage
Voltage Range
Efficiency (typ)
Current (typ)
V
V
DC24
DC18-36
82
Input
(*1)
(*1)
%
A
73
0.151
3.3
0.800
2.64
78
0.160
5
81
0.154
0.152
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
0.250
15
0.200
3
± 12
0.125
± 15
0.100
0.600
(*2)
W
Maximum Line Regulation (Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
40
100
80
600
Output
Temperature Coefficient
(Ambient temperature -40℃ to +50℃ )
80mV
200mV
300mV
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.67
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Isolation
Standards Safety Standards
Weight (typ)
Size (W x H x D)
g
mm
7
Mechanical
27.8 x 17.9 x 9.2
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
CC3-4803SS-E
CC3-4805SS-E
CC3-4812SS-E
CC3-4812DS-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC48
DC36-76
Voltage Range
Efficiency (typ)
Current (typ)
Input
(*1)
(*1)
%
A
73
0.075
3.3
0.800
2.64
79
0.079
5
82
0.076
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
0.250
15
0.200
3
± 12
0.125
± 15
0.100
0.600
(*2)
W
Maximum Line Regulation (Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
40
100
80
600
Output
Temperature Coefficient
(Ambient temperature -40℃ to +50℃ )
80mV
200mV
300mV
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Isolation
Standards Safety Standards
Weight (typ)
Size (W x H x D)
g
mm
7
Mechanical
27.8 x 17.9 x 9.2
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.
ꢀ0
SIP
CC3-E(
)
Outline Drawing
CC3-xxxxxS-Eꢀ(SIPꢀtype)
9.2
Shape/Dimensions
(
)
1 t=0.3
2.47
P
P
P
P
22.86
2P
P
P
P
P
2.47
6
17.78
5.01
P=2.54
27.8
a
5
Recommended measurements for mounting board
1
2
3
4
7
8
9 10
27.8
a
2.47
22.86
2.47
17.78
P=2.54
2-ø1.5 (land diameter ø2.5)
4
SMD mounting space
P
P
P
P
2P
P
P
P
Unit: mm
Allowable tolerance is 0.5 if not specified separately.
9-ø0.8 (land diameter ø2.0)
Connection diagram
CC3-xxxxSS-E
CC3-xxxxDS-E
Terminal connections
No.1 +Vout
No.2 NC
Terminal connections
No.1 +Vout
No.2 COM
No.3 COM
No.4 –Vout
No.5 TRM
No.6 NC
1
2
3
4
5
7
8
9
10
1
2
3
4
5
7
8
9
10
No.3 NC
No.4 –Vout
No.5 TRM
No.6 NC
Load
Load Load
No.7 RC
No.7 RC
No.8 –Vin
No.9 +Vin
No.10 +Vin
No.8 –Vin
No.9 +Vin
No.10 +Vin
Derating Curve
100
80
60
40
20
0
Natural air cooling
a
b
a:0.5m/s(100LFM)
b:1m/s(200LFM)
-40 -20
ꢀ
0
ꢀ
20
ꢀ
40ꢀ60ꢀ80
ꢀ
100
Ambient temperature (°C)
Output power derating by ambient temperature
(common specification)
・All specifications are subject to change without notice.
ꢀꢀ
CC6-E
CC6-E Specifications
MODEL
CC6-0503Sx-E
CC6-0505Sx-E
CC6-0512Sx-E
CC6-0512Dx-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC5.0
DC4.5-9.0
Voltage Range
Efficiency (typ)
Current (typ)
Input
(*1)
(*1)
%
A
76
1.042
3.3
1.200
3.96
79
1.266
5
1.000
5
82
1.463
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
0.500
15
0.400
± 12
0.250
± 15
0.200
(*2)
W
6
Maximum Line Regulation(Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
40
100
80
600
Output
Temperature Coefficient
(Ambient temperature -40℃ to +50℃ )
80mV
200mV
300mV
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Standards Safety Standards
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Isolation
Weight (typ)
Size (W x H x D)
g
mm
5.8
Mechanical
DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
CC6-1203Sx-E
CC6-1205Sx-E
CC6-1212Sx-E
CC6-1212Dx-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC12
DC9.0-18
Voltage Range
Efficiency (typ)
Current (typ)
Input
(*1)
(*1)
%
A
78
0.423
3.3
82
0.610
5
85
0.588
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
0.500
15
0.400
6
± 12
0.250
± 15
0.200
1.200
(*2)
W
3.96
Maximum Line Regulation(Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
40
100
80
600
Output
Temperature Coefficient
(Ambient temperature -40℃ to +50℃ )
80mV
200mV
300mV
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Standards Safety Standards
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Isolation
Weight (typ)
Size (W x H x D)
g
mm
5.8
Mechanical
DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.
ꢀ2
CC6-E
MODEL
CC6-2403Sx-E
CC6-2405Sx-E
CC6-2412Sx-E
CC6-2412Dx-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC24
DC18-36
87
Voltage Range
Efficiency (typ)
Current (typ)
Input
(*1)
(*1)
%
A
77
0.214
3.3
81
0.309
5
86
0.291
0.287
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
0.500
15
0.400
6
± 12
0.250
± 15
0.200
1.200
(*2)
W
3.96
Maximum Line Regulation(Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
40
100
80
600
Output
Temperature Coefficient
(Ambient temperature -40℃ to +50℃ )
80mV
200mV
300mV
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Standards Safety Standards
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Isolation
Weight (typ)
Size (W x H x D)
g
mm
5.8
Mechanical
DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
CC6-4803Sx-E
CC6-4805Sx-E
CC6-4812Sx-E
CC6-4812Dx-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC48
DC36-76
Voltage Range
Efficiency (typ)
Current (typ)
Input
(*1)
(*1)
%
A
77
0.107
3.3
81
0.154
5
86
0.145
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
0.500
15
0.400
6
± 12
0.250
± 15
0.200
1.200
(*2)
W
3.96
Maximum Line Regulation(Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
40
100
80
600
Output
Temperature Coefficient
(Ambient temperature -40℃ to +50℃ )
80mV
200mV
300mV
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Standards Safety Standards
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Isolation
Weight (typ)
Size (W x H x D)
g
mm
5.8
Mechanical
DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.
ꢀꢁ
CC6-E
Outline Drawing
CC6-xxxxxF-Eꢀ(DIPꢀtype)
21.1 0.2
Shape/Dimensions
Recommended measurements for mounting board
20.32
Outer shape of product
t=0.3
7-ø1.0 (land diameter ø2.0)
17.78
22.86
2.54
2.54
b
a
2.7
2-ø1.5 (land diameter ø2.5)
22.86
a
b
4
3
2
7-0.3×0.6
1.0
5
6
2.7
Unit: mm
1
7
a
Allowable tolerance is 0.5 if not specified separately.
b
CC6-xxxxxR-Eꢀ(SMDꢀtype)
21.1 0.2
Shape/Dimensions
Recommended measurements for mounting board
Outer shape of product
t=0.3
22.86
Coplanarity: 0.1 or lower
26.16
1.8
1.8
3
2
4
5
7-0.3×0.6
3.2
22.0
28.4
3.2
6
7
1
Unit: mm
Allowable tolerance is 0.5 if not specified separately.
Connection diagram
CC6-xxxxSx-E
CC6-xxxxDx-E
Terminal connections
No.1 +Vin
No.2 RC
No.3 –Vin
No.4 NC
No.5 –Vout
No.6 TRM
No.7 +Vout
Terminal connections
No.1 +Vin
+Vin
1
+Vout
TRM
+Vin
1
+Vout
7
6
5
7
6
5
No.2 RC
No.3 –Vin
No.4 –Vout
No.5 Common out
No.6 TRM
No.7 +Vout
TRM
COM
–Vout
RC
2
RC
2
–Vout
4 NC
4
3
3
–Vin
–Vin
Derating Curve
100
80
60
40
20
0
Natural air cooling
a
b
a:0.5m/s(100LFM)
b:1m/s(200LFM)
-40 -20
ꢀ 0ꢀ 20ꢀ 40ꢀ60ꢀ80ꢀ100
Ambient temperature (°C)
Output power derating by ambient temperature
(common specification)
・All specifications are subject to change without notice.
ꢀ4
CC10-E
CC10-E Specifications
MODEL
CC10-0503Sx-E CC10-0505Sx-E
CC10-0512Sx-E
CC10-0512Dx-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC5.0
DC4.5-9.0
Voltage Range
Efficiency (typ)
Current (typ)
Input
(*1)
(*1)
%
A
84
83
2.313
1.964
3.3
2.381
5
2.286
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
15
± 12
0.400
± 15
0.320
2.500
8.25
2.000
10
0.800
0.640
(*2)
W
9.6
Maximum Line Regulation(Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
40
100
80
600
Output
Temperature Coefficient
(Ambient temperature -40℃ to +50℃ )
80mV
200mV
300mV
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Standards Safety Standards
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Isolation
Weight (typ)
Size (W x H x D)
g
mm
10
Mechanical
DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
CC10-1203Sx-E CC10-1205Sx-E
CC10-1212Sx-E
CC10-1212Dx-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC12
DC9.0-18
88
Voltage Range
Efficiency (typ)
Current (typ)
Input
(*1)
(*1)
%
A
84
0.318
3.3
86
0.969
5
86
1.047
1.136
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
15
± 12
450
± 15
360
2.500
8.25
2.000
10
1000
800
(*2)
W
12
40
100
10.8
80
600
Maximum Line Regulation(Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Standards Safety Standards
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Isolation
Weight (typ)
Size (W x H x D)
g
mm
10
Mechanical
DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.
ꢀꢂ
CC10-E
MODEL
CC10-2403Sx-E CC10-2405Sx-E
CC10-2412Sx-E
CC10-2412Dx-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC24
DC18-36
87
Voltage Range
Efficiency (typ)
Current (typ)
Input
(*1)
(*1)
%
A
84
0.409
3.3
86
0.484
5
86
0.523
0.575
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
15
± 12
0.450
± 15
0.360
2.500
8.25
2.000
10
1.000
0.800
(*2)
W
12
40
100
10.8
80
600
Maximum Line Regulation(Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Standards Safety Standards
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Isolation
Weight (typ)
Size (W x H x D)
g
mm
10
Mechanical
DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
CC10-4803Sx-E CC10-4805Sx-E
CC10-4812Sx-E
CC10-4812Dx-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC48
DC36-76
88
Voltage Range
Efficiency (typ)
Current (typ)
Input
(*1)
(*1)
%
A
84
0.205
3.3
86
0.242
5
86
0.262
0.284
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
12
15
± 12
0.450
± 15
0.360
2.500
8.25
2.000
10
1.000
0.800
(*2)
W
12
40
100
10.8
80
600
Maximum Line Regulation(Within input voltage range) mV
Maximum Load Regulation (0-100% load) (*3) mV
20
40
Output
Temperature Coefficient
80mV
200mV
300mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max)(*4)
%
± 3
± 5
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*5) mVp-p
VDC
(*6)
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
Available
± 11.4- ± 15.0
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Standards Safety Standards
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Isolation
Weight (typ)
Size (W x H x D)
g
mm
10
Mechanical
DIP: 35.56 x 8.5 x 22.6 / SMD: 35.56 x 8.8 x 22.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Note: For 12V/ ± 12V models, output power can be set to 15V/ ± 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For ± 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25°C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
・All specifications are subject to change without notice.
ꢀꢃ
CC10-E
Outline Drawing
CC10-xxxxxF-Eꢀ(DIPꢀtype)
Shape/Dimensions
Recommended measurements for mounting board
22.6 0.2
30.48
Outer shape of
product
t=0.3
7-ø1.0 (land diameter ø2.0)
25.4
35.56
5.08
25.4
5.08
2-ø1.5 (land diameter ø2.5)
35.56
a
b
a
b
2.7
2.7
3
2
4
5
6
7
7-0.3×0.6
Unit: mm
1
b
a
Allowable tolerance is 0.5 if not specified separately.
1.0
CC10-xxxxxR-Eꢀ(SMDꢀtype)
Shape/Dimensions
Recommended measurements for mounting board
22.6 0.2
Outer shape of
product
t=0.3
Coplanarity: 0.1 or lower
35.56
38.86
1.8
1.8
3
2
4
5
6
7
3.2
34.6
41.0
3.2
7-0.3×0.6
1
Unit: mm
Allowable tolerance is 0.5 if not specified separately.
Connection diagram
CC10-xxxxSx-E
CC10-xxxxDx-E
Terminal connections
No.1 +Vin
No.2 RC
No.3 –Vin
No.4 NC
No.5 –Vout
No.6 TRM
No.7 +Vout
+Vin
+Vout
Terminal connections
No.1 +Vin
No.2 RC
No.3 –Vin
No.4 –Vout
No.5 Common out
No.6 TRM
No.7 +Vout
+Vin
+Vout
7
6
5
1
7
6
5
1
TRM
TRM
COM
–Vout
RC
2
RC
–Vout
2
3
4 NC
4
3
–Vin
–Vin
Derating Curve
100
80
60
40
20
0
Natural air cooling
a
b
a:0.5m/s(100LFM)
b:1m/s(200LFM)
-40 -20
ꢀ 0ꢀ 20ꢀ 40ꢀ60ꢀ80ꢀ100
Ambient temperature (°C)
Output power derating by ambient temperature
(common specification)
・All specifications are subject to change without notice.
ꢀꢄ
CC15-E
CC15-E Specifications
MODEL
CC15-2403Sx-E
CC15-2405Sx-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC24
DC18-36
89
Voltage Range
Efficiency (typ)
Current (typ)
Input
(*1)
(*1)
%
A
0.695
3.3
4.500
14.85
65
0.702
5
3.000
15
100
200
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
(*2)
W
Maximum Line Regulation(Within input voltage range) mV
Maximum Load Regulation (0-100% load) mV
120
Output
Temperature Coefficient
80mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max)(*3)
%
+5/-3
40/120
Not available
Available
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*4) mVp-p
(*5)
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Standards Safety Standards
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Isolation
Weight (typ)
Size (W x H x D)
g
mm
12.5
Mechanical
DIP: 37.55 x 7.0 x 32.1 / SMD: 37.55 x 7.5 x 32.1
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) Output voltage includes input change, load change (balanced load), and temperature change.
(*4) In 50MHz, Ta=25°C.
(*5) Latch method Resumes by restarting input or resetting remote on/off.
・All specifications are subject to change without notice.
ꢀ8
CC15-E
Outline Drawing
CC15-xxxxxSF-Eꢀ(DIPꢀtype)
Shape/Dimensions
Recommended measurements for mounting board
38.1
32.1
Outer shape of product
t=0.3
6.075
25.4
6.075
37.55
25-ø1.0 (land diameter ø2.0)
2-ø1.5 (land diameter ø2.5)
2.7
a
b
a
b
10
9
8
7
6
5
4
3
2
1
11
12
13
14
15
16
1.0
6.075
31.475
17-0.3×0.6
17
P=2.54
Unit: mm
37.55
2.7
b
a
Allowable tolerance is 0.5 if not specified separately.
CC15-xxxxxSR-Eꢀ(SMDꢀtype)
Shape/Dimensions
Recommended measurements for mounting board
38.1
32.1
Outer shape of product
t=0.3
40.9
Coplanarity: 0.1 or lower
10
9
8
7
6
5
4
3
2
1
11
12
13
14
15
16
17-0.3×0.6
17
3.2
36.6
43.0
3.2
P=2.54
1.8
1.8
Unit: mm
Allowable tolerance is 0.5 if not specified separately.
Connection diagram
Terminal connections
1
17
RC
2
3
No.1 NC
No.2 NC
No.3 RC
No.4 NC
No.5 NC
No.6 +Vin
No.7 +Vin
No.8 –Vin
No.9 –Vin
No.10 NC
No.11 NC
4
–Vout
No.12 +Vout
No.13 +Vout
No.14 +Vout
No.15 –Vout
No.16 –Vout
No.17 NC
5
16
15
14
13
12
11
+Vin
6
7
8
9
+Vout
–Vin
10
Derating Curve
100
80
60
40
20
0
Natural air cooling
a
b
a:0.5m/s(100LFM)
b:1m/s(200LFM)
-40 -20
ꢀ 0ꢀ 20ꢀ 40ꢀ60ꢀ80ꢀ100
Ambient temperature (°C)
Output power derating by ambient temperature
(common specification)
・All specifications are subject to change without notice.
ꢀꢅ
CC25-E
CC25-E Specifications
MODEL
CC25-2403Sx-E
CC25-2405Sx-E
ITEMS/UNITSꢀ
Nominal Voltage
V
V
DC24
DC18-36
90
Voltage Range
Efficiency (typ)
Current (typ)
Input
(*1)
(*1)
%
A
1.146
3.3
7.500
24.75
65
1.157
5
5.000
25
100
200
Nominal Voltage
Maximum Current
Maximum Power
VDC
A
(*2)
W
Maximum Line Regulation (Within input voltage range) mV
Maximum Load Regulation (0-100% load) mV
120
Output
Temperature Coefficient
80mV
(Ambient temperature -40℃ to +50℃ )
Max Power Total Regulation (max)(*3)
%
+5/-3
Maximum Ripple & Noise (typ/max)
Voltage Adjustable Range
Over Current Protection
(*4) mVp-p
VDC
(*5)
40/120
Not available
Available
Function Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Not available
Available
-40 to +85
-40 to +85
℃
℃
% RH
% RH
Storage Temperature
Operating Humidity
Storage Humidity
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38℃ in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 3 directions, 3 times for each, in non-operation
Environment
Vibration
Shock
Withstand Voltage
Isolation Resistance
Standards Safety Standards
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50MΩ min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Isolation
Weight (typ)
Size (W x H x D)
g
mm
20
Mechanical
DIP: 42.65 x 7.0 x 44.9 / SMD: 42.65 x 7.5 x 44.9
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) The maximum output power value is between -40°C and +50°C. For use in outside this temperature range, derating is needed.
(*3) Output voltage includes input change, load change (balanced load), and temperature change.
(*4) In 50MHz, Ta=25°C.
(*5) Latch method Resumes by restarting input or resetting remote on/off.
・All specifications are subject to change without notice.
20
CC25-E
Outline Drawing
CC25-xxxxSF-Eꢀ(DIPꢀtype)
Shape/Dimensions
Recommended measurements for mounting board
43.2
44.9
Outer shape of product
t=0.3
6.075
30.5
6.075
42.65
25-ø1.0 (land diameter ø2.0)
2-ø1.5 (land diameter ø2.5)
2.7
b
a
b
13
12
11
10
14
15
16
17
18
19
20
21
22
23
24
1.0
9
8
7
25-0.3×0.6
a
6.075
6
5
4
3
2
1
2.7
36.575
42.65
P=2.54
25
b
a
Unit: mm
Allowable tolerance is 0.5 if not specified separately.
CC25-xxxxSR-Eꢀ(SMDꢀtype)
Recommended measurements for mounting board
Shape/Dimensions
43.2
44.9
Outer shape of product
t=0.3
46.0
Coplanarity: 0.1 or lower
1.8
1.8
13
12
11
10
14
15
16
17
18
19
20
21
22
23
24
9
8
7
6
5
4
3
2
1
3.2
41.7
48.1
3.2
P=2.54
25
Unit: mm
Allowable tolerance is 0.5 if not specified separately.
Connection diagram
Terminal connections
No.1 NC
No.2 NC
No.3 NC
No.4 RC
No.5 NC
No.6 NC
No.7 –Vin
No.8 –Vin
No.9 –Vin
1
2
25
24
23
22
21
20
19
18
17
16
15
14
–Vout
No.10 +Vin
No.11 +Vin
No.12 +Vin
No.13 NC
No.19 –Vout
No.20 –Vout
No.21 –Vout
No.22 –Vout
No.23 –Vout
No.24 –Vout
No.25 NC
RC
3
4
5
6
–Vin
7
No.14 NC
8
No.15 +Vout
No.16 +Vout
No.17 +Vout
No.18 +Vout
9
10
11
12
13
+Vout
+Vin
Derating Curve
100
Natural air cooling
a
b
80
60
40
20
0
a:0.5m/s(100LFM)
b:1m/s(200LFM)
-40 -20
ꢀ 0ꢀ 20ꢀ 40ꢀ60ꢀ80ꢀ100
Ambient temperature (°C)
Output power derating by ambient temperature
(common specification)
・All specifications are subject to change without notice.
21
CC-E
CC-E Instruction Manual
1. Control functions/Protection functions/Connections
1-2. Output voltage adjusting ter-
minal (TRM) (1.5-10W type)
Output voltage can be set to the values shown in the figure
below by connecting the TRM terminal to the -Vout termi-
nal.
1. Remote On/Off terminal (RC)
1.5-10W type
Open collector is recommended as the connection system.
Consult us for use with other systems.
Use a transistor with "V : Vin or over" and "Ic: 1mA or
CE
over".
When not using this function (always on), set the TRM ter-
minal to open.
Output is switched off by setting the RC terminal open, and
switched on by setting the RC terminal to LOW (0-0.4V).
Note that when the output voltage is set high by this func-
tion, derating of output current is necessary according to
the maximum power.
+Vin
+Vout
RC
control
signal
DIP/SMDmodels
Model name
CCꢀ–xx03Sx–E
CCꢀ–xx05Sx–E
CCꢀ–xx12Sx–E
CCꢀ–xx12Dx–E
RC
Open
3.3V
5V
Connection to -Vout Fig.
3.6V
6V
1
1
1
2
–Vin
–Vout
12V
15V
±15V
When not using this function (always on), short-circuit be-
tween RC terminal and -Vin terminal.
±12V
ꢀ
To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.
+Vin
+Vout
Fig.1
+Vin
When not
using this
function
3.3V
5V
12V
3.6V
6V
15V
+Vout
TRM
+Vin
–Vin
+Vout
TRM
RC
(always on)
–Vin
–Vout
–Vin
Fig.2
+Vin
–Vout
–Vout
15/25W type
+12V
+15V
+Vout
TRM
+Vin
+Vout
Output is switched on by setting the RC terminal to open,
and switched off by setting the RC terminal to HIGH (con-
necting to Vin terminal).
Load
TRM
COM
–Vout
Load
Load
COM
–Vout
Load
–12V
–Vin
–Vin
–15V
+Vin
+Vout
SIPmodels
Model name
CC3–xx03SS–E
CC3–xx05SS–E
CC3–xx12SS–E
CC3–xx12DS–E
RC
control
signal
RC
Fig.
Model name
3.3V
Connection to -Vout
3.67V
6V
3
3
3
4
–Vin
–Vout
5V
12V
15V
When not using this function (always on), set the RC termi-
nal to open.
±12V
±15V
Fig.3
+Vin
+Vout
When not
using this
function
RC
Load
Fig.4
Load
3.3V, 5V, 12V
3.67V, 6V, 15V
(always on)
–Vin
–Vout
Load Load
+12V
Load Load
+15V
–12V
–15V
・All specifications are subject to change without notice.
22
CC-E
For ±the 12V output model, output voltage can be set to
24V single output by making the COM terminal and TRM
terminal open. And output voltage can be set to 30V single
output by making the COM terminal open and connecting
the TRM terminal to the -Vout terminal.
Adding a resistance Rb between TRM terminal and
+Vout terminal, to set the output voltage low
*5 Vout = 3.3 - 15.53/(39.6+Rb) [Rb ≧ 62]
*6 Vout = 5.01 - 52.55/(31.8+Rb) [Rb ≧ 160]
*7 Vout = 12.01 - 431.1/(57+Rb) [Rb ≧ 620]
*8 Vout = 12.02 - 968.5/(103+Rb) [Rb ≧ 1500]
models
Model name
Calculating connected resistance Ra, Rb (kΩ) from set out-
put voltage Vout (V)
Adding a resistance Ra between TRM terminal and -Vout
terminal, to set the output voltage high
*1 Ra = 9.59/(Vout-3.3) - 32
COM terminal TRM terminal
Single output
Fig.
Open
Open
Open
Connection to -Vout
* To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.
Fig.5
+Vin
Fig.6
+Vin
*2 Ra = 17.64/(Vout-5.01) - 17.8
*3 Ra = 50.53/(Vout-12.01) - 16.9
*4 Ra = 53.55/(Vout-12.02) - 18
+Vout
TRM
+Vout
TRM
30V
24V
COM
–Vout
COM
–Vout
–Vin
–Vin
Adding a resistance Rb between TRM terminal and +Vout
terminal, to set the output voltage low
*5 Rb = 15.53/(3.3-Vout) - 39.6
models
Model name
COM terminal TRM terminal
Single output
Fig.
Open
Open
Open
*6 Rb = 52.55/(5.01-Vout) - 31.8
*7 Rb = 431.1/(12.01-Vout) - 57
Connection to -Vout
*8 Rb = 968.5/(12.02-Vout) - 103
Fig.7
Fig.8
Fig.9
Fig.10
*5,*6,*7
3.3~3.6V
5~6V
3.15~3.3V
4.75~5V
+Vout
TRM
+Vout
TRM
12~15V
11.4~12V
Rb
Load
Load
30V
24V
Ra
–Vout
–Vout
*1,*2,*3
1-3. Output voltage adjusting func-
tion (adding external resistance)
(1.5-10W type)
Fig.11
Fig.12
*8
+12~+15V
+11.4~+12V
+Vout
TRM
COM
+Vout
TRM
COM
Rb
Load
Load
Output voltage can be varied in the range shown in the fig-
ure below by connecting a resistance (Ra, Rb) between the
TRM terminal and the -Vout terminal or between the TRM
terminal and +Vout terminal.
Note that when the output voltage is set high, derating
of output current is necessary according to the maximum
power.
Load
Load
Ra
*4
–Vout
–Vout
–12~–15V
–11.4~–12V
models
Connection between
-Vout and Ra
Connection between
+Vout and Rb
Model name
Fig.
Fig.
to
to
to
to
to
to
to
models
to
Connection between
-Vout and Ra
Connection between
+Vout and Rb
Model name
Fig.
Fig.
to
to
to
to
to
to
to
Calculating output voltage Vout (V) from connected resis-
tance Ra, Rb (kΩ)
Adding a resistance Ra between TRM terminal and -Vout
terminal, to set the output voltage high
*1 Vout = 3.3 + 1.04/(2.83+Ra)
to
* To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.
Calculating output voltage Vout (V) from connected resis-
tance Ra, Rb (kΩ)
*2 Vout = 5 + 12.75/(12.69+Ra)
Adding a resistance Ra between TRM terminal and -Vout
terminal, to set the output voltage high
*1 Vout = 3.3 + 9.59/(32+Ra)
*3 Vout = 12 + 48.4/(16.18+Ra)
*4 Vout = 12 + 54.7/(18+Ra)
*2 Vout = 5.01 + 17.64/(17.8+Ra)
*3 Vout = 12.01 + 50.53/(16.9+Ra)
*4 Vout = 12.02 + 53.55/(18+Ra)
Adding a resistance Rb between TRM terminal and
+Vout terminal, to set the output voltage low
*5 Vout = 3.3 - 1.69/(3.66+Rb) [Rb ≧ 7.6]
*6 Vout = 5 - 12.78/(17.79+Rb) [Rb ≧ 33.3]
*7 Vout = 12 - 184.1/(35.54+Rb) [Rb ≧ 271.3]
*8 Vout = 12 -470.3/(61.75+Rb) [Rb ≧ 722.1]
・All specifications are subject to change without notice.
23
CC-E
Calculating connected resistance Ra, Rb (kΩ) from set out-
put voltage Vout (V)
1-5. Over voltage protection
Adding a resistance Ra between TRM terminal and -Vout
terminal, to set the output voltage high
*1 Ra = 1.04/(Vout-3.3) - 2.83
An over voltage protection function is not incorporated in
the model. Be careful if an external voltage over the nomi-
nal voltage is applied, damage may be caused.
*2 Ra = 12.75/(Vout-5) - 12.69
*3 Ra = 48.4/(Vout-12) - 16.18
*4 Ra = 54.7/(Vout-12) - 18
1-6. Low input voltage protection
This series is equipped with the low input voltage protec-
tion in order to prevent malfunction due to low input volt-
age. The converter stops operation if the input voltage
become lower than the set voltage. The set ranges are
shown in the table below.
Adding a resistance Rb between TRM terminal and
+Vout terminal, to set the output voltage low
*5 Rb = 1.69/(3.3-Vout) - 3.66
*6 Rb = 12.78/(5-Vout) - 17.79
*7 Rb = 184.1/(12-Vout) - 35.54
Model name
Input voltage range
Voltage range set for protection circuit
to
to
to
to
to
to
to
to
to
to
to
*8 Rb = 470.3/(12-Vout) - 61.75
Fig.13
Fig.14
to
To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.
Ra
Rb
*1,*2,*3
*5,*6,*7
Load
Load
3.3~3.67V、5~6V、12~15V
1-7. Insulation withstand voltage
3.15~3.3V、4.75~5V、11.4~12V
The insulation withstand voltage between input and output,
and between terminal and case, is AC500V.
Fig.15
Fig.16
1-8. Series/Parallel connections
Series connection
Rb
Ra
*4
*8
Load Load
Load Load
+12~+15V
–12~–15V
–11.4~–12V
+11.4~+12V
Serial connection is applicable by wiring as shown in the
figure below (left). If output voltage is not generated by this
connection, connect a Schottky diode in which the forward
voltage is possibly low.
1-4. Over current protection
1.5-10W type
An over current protection circuit is incorporated in the
model, and if over current occurs, the output voltage is
lowered. By removing the over current and shorted condi-
tions, the output voltage automatically resumes. Note that
if the over current status continues for 30 seconds or over,
the internal elements of the converter may be deteriorated
or damaged. The current value, from which it is judged as
an over current, is not to be lower than the nominal current
value. If the output voltage does not resume even after re-
moving the over current conditions and any causes, turn off
the power or remote control once, and then restart it.
Also note that the Schottky diode should have a reverse
voltage that is twice or over the value of the voltage be-
tween +Vout and -Vout.
And the output current should be the same or lower than
the nominal current value, whichever is smaller in the con-
verters.
+Vin
+Vout
+Vin
+Vout
–Vin
+Vin
–Vout
+Vout
–Vin
+Vin
–Vout
+Vout
15/25W type
–Vin
–Vout
–Vin
–Vout
An over current protection circuit is incorporated in the
model, and if over current occurs, the output voltage is
lowered and the converter is stopped and latched. The
output voltage does not automatically resume even after
removing the over current and shorted conditions.
To resume output voltage, restart input or reset remote on/
off.
Parallel connection
Parallel connection is not applicable.
The current value, from which it is judged as an over cur-
rent, is not to be lower than the nominal current value.
・All specifications are subject to change without notice.
24
CC-E
2. Noise reduction methods
2-1. Ripple noise measurement method
2-3. Output ripple & noise
The measured value of the converter noise may differ de-
pending on the measurement method. Measurement should
be conducted in a position close to the output terminal.
When connecting a prove, do not allow a loop to be config-
ured in order not to pick up flux.
To reduce Output ripple & noise, connect a capacitor to
the output of the converter. In addition, reduction can be
enhanced if a π type filter is incorporated as shown in the
figure below. In this case, use of a coil with around 100µH
is recommended.
As well, note that the spike voltage greatly differs depend-
ing on the ripple voltmeter and frequency band of the oscil-
loscope.
+Vin
+Vout
+Vin
+Vout
Our noise measurement is conducted by the wiring shown
in the figure below and in the frequency band of 50MHz.
–Vin
–Vout
–Vin
–Vout
10mm
20mm
When the distance to the load from the output of the con-
verter is long, connect the capacitor as close as possible
to the load.
To reduce output spike noise, connect a ceramic capacitor
with around 1µF to the output of the converter.
A
lout
+Vin
+Vout
–Vout
Vout
V
0.1µF
Vin
V
Iin
50Ω coaxial cable
–Vin
A
1.5m
Ripple
Oscilloscope
+Vin
–Vin
+Vout
–Vout
or
voltmeter
50MHz
50MHz
End-point: 50Ω+0.1µF
1MF
2-2. Input ripple noise
This series is equipped with a built-in capacitor for input.
Therefore, this series can operate without an external
capacitor connected to input. However, by connecting a
capacitor, input ripple noise and input return noise can be
reduced.
2-4. Capacity of external capaci-
tor connected to output
Note that if a capacitor with capacity over the value shown
in the table below is connected to the output, or several
capacitors with low impedance are connected in parallel,
operation of the converter may become unstable.
In addition, it is more effective if a π type filter is installed
as shown in the figure below.
+Vin
+Vout
+Vin
+Vout
Model name
Electrostatic capacitance (µF) max.
–Vin
–Vout
–Vin
–Vout
When the distance to the input of the converter from the
input power supply is long, attach a capacitor as close as
possible to the input terminal.
+Vin
+Vout
–Vin
–Vout
When the distance to the input of the converter from the
input power supply is long, the impedance of the input line
can become high, causing high spike noise.
In this case, it is recommended to connect a capacitor as
close as possible to the input of the DC-DC converter.
・All specifications are subject to change without notice.
25
CC-E
2-5. Common mode noise
2-6. Radiation noise
For products other than with 10W, capacitors are not con-
nected between the primary GND and the secondary GND.
To reduce common mode noise, connect a capacitor with
around 1000pF between the primary GND and the second-
ary GND, as shown in the figure below.
In this case, note that if the capacitor that is connected is
too large, coupling capacitance between input and output
becomes large.
Radiation noise of the converter can be reduced by con-
necting the case terminal to the input or output GND ter-
minal. The effectiveness varies depending on the device.
Check it on the actual device.
Regarding wiring, use GND line and solid pattern for the
bottom of the converter as much as possible.
- SMD models are not equipped with case terminals.
Also be careful about the withstand voltage of the capacitor
(500V or over is desirable with consideration of the insula-
tion withstand voltage).
+Vin
+Vout
–Vin
–Vout
For products with 10W, capacitors with 1000pF are inter-
nally connected between primary and secondary.
3. Soldering conditions/Cleaning conditions
3-1. Soldering conditions
3-2. Cleaning method
Board cleaning after soldering is not recommended. How-
ever, the cleaning fluids and conditions shown in the table
below have been tested and proved to have no problem.
These fluids and conditions can be used. Consult us for
using cleaning fluids other than those shown below.
●Soldering conditions
ꢀDIP models / SIP models
Observe the following conditions in soldering board.
Solder dip
260°C, 10s max.
Soldering copper
380°C, 3s max.
Cleaning fluids and test conditions
Cleanthrough 750H
SMD models
Lead-free soldering / High-temperature reflow process
(1) Cleaning (shaking) at 60°C for 4 minutes
(2) Rinsing (shaking in water) at 60°C for 4 minutes
(3) Rinsing (shaking in water) at ordinary temperature -
40°C for 4 minutes
30p20s
Surface temperature of parts
245˚C max.
225˚C min.
(4) Drying at 70°C for 6 minutes
180˚C
150˚C
Pine alpha ST100S
(1) Cleaning (shaking) at 60°C for 5 minutes
(2) Rinsing (shaking in water) at 30°C for 3 minutes
(3) Drying at 70°C for 6 minutes
1 to 3˚C/s 40 to 100s 1 to 4˚C/s 1 to 5˚C/s
Terpene Cleaner EC-7R
(1) Cleaning (shaking) at 60°C for 5 minutes
(2) Rinsing (shaking in IPA) at 30°C for 10 minutes
(3) Drying at 70°C for 6 minutes
Isopropyl alcohol
(1) Ultrasonic waves at 60°C for 1 minute
(2) Cool bath cleaning R.T. for 1 minute
(3) Vapor cleaning at 83°C for 1 minutes
Asahiklin AK-225AES
(1) Ultrasonic waves at 50°C for 2 minutes
(2) Cool bath cleaning R.T. for 2 minutes
・All specifications are subject to change without notice.
CC3-0503SR-E 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
CC3-0503SS-E | TDK | DC-DC Regulated Power Supply Module, 1 Output, 2.64W, Hybrid, ROHS COMPLIANT, SIP-10/9 | 获取价格 | |
CC3-0505SF-E | TDK | Ultra Compact, 1.5W to 25W Single and Dual DC-DC Converters | 获取价格 | |
CC3-0505SR-E | TDK | DC-DC Regulated Power Supply Module, 1 Output, 3W, Hybrid, ROHS COMPLIANT, SMD-7 | 获取价格 | |
CC3-0505SS-E | TDK | DC-DC Converters | 获取价格 | |
CC3-0512DF-E | TDK | Ultra Compact, 1.5W to 25W Single and Dual DC-DC Converters | 获取价格 | |
CC3-0512DR-E | TDK | Insulation type DC-DC converter | 获取价格 | |
CC3-0512DS-E | TDK | DC-DC Regulated Power Supply Module, 2 Output, 3W, Hybrid, ROHS COMPLIANT, SIP-10/9 | 获取价格 | |
CC3-0512SF-E | TDK | Ultra Compact, 1.5W to 25W Single and Dual DC-DC Converters | 获取价格 | |
CC3-0512SR-E | TDK | Ultra Compact, 1.5W to 25W Single and Dual DC-DC Converters | 获取价格 | |
CC3-0512SS-E | TDK | DC-DC Regulated Power Supply Module, 1 Output, 3W, Hybrid, ROHS COMPLIANT, SIP-10/9 | 获取价格 |
CC3-0503SR-E 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8