CE-3101-T [TDK]
DC-DC Regulated Power Supply Module, 1 Output, 1.2W, Hybrid, ROHS COMPLIANT PACKAGE-8;型号: | CE-3101-T |
厂家: | TDK ELECTRONICS |
描述: | DC-DC Regulated Power Supply Module, 1 Output, 1.2W, Hybrid, ROHS COMPLIANT PACKAGE-8 |
文件: | 总4页 (文件大小:1347K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
ꢀ
Non-insulationꢀtypeꢀDC-DCꢀconverter
CE-3101
Y
E
A
R
1
S
warranty
■ Features
●Slim type
●SMD type
●Short in height: 4.5mm
●Equipped with a function to vary output over a wide range
●Equipped with Remote On/Off function
●5-side metal-shielded low noise design
●Delivery in tray or by taping available
■ Model-naming method
ꢀ ꢀCE-3101-T
Packing type
T: Taping
None: Tray
Model number
Series name
■ Applications
■ Conformity to RoHS Directive
This means that, in conformity with EU Directive
2002/95/EC, lead, cadmium, mercury, hexavalent chro-
mium, and specific bromine-based flame retardants, PBB
and PBDE, have not been used, except for exempted ap-
plications.
■ Product Line up
Model name
Input voltage
Output voltage
Output current
Output power
CE-3101
4.5V-5.5V
40V
30mA
1.2W
00ꢀ-0ꢀ/2008042ꢀ/etl_ce_3ꢀ0ꢀ
・All specifications are subject to change without notice.
2
CE-3101
CE-3101 Specifications
MODEL
CE-3101
ITEMS/UNITS
Voltage Range
Efficiency (typ)
Nominal Voltage
Maximum Current
Maximum Power
V
(*1) %
VDC
A
DC4.5-5.5
Input
72
40
0.03
W
1.2
Voltage Setting Accuracy
%
DC38.5-41.5V
Output
Function
Maximum Line Regulation
∓ 1%
Within input voltage range(max)
Maximum Load Regulation (0-100%)(max)
Temperature Coefficient (-10°C to 60°C)(max)
∓ 1%
∓ 1.5
250
Available
Not available
Available
%
Maximum Ripple & Noise (max)(*2) mVp-p
Over Current Protection (*3)
Over Voltage Protection
Output Voltage Setting
Remote ON/OFF Control (*4)
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
A
Available (external voltage application system or external resistance system)
℃
℃
-10 to +60
-30 to +85
%RH 10-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
%RH 10-95 (the conditions of maximum 38°C in wet bulb temperature and non-condensation should be ensured.)
10-500Hz, 15 minutes sweep and 98m/s² (10G) acceleration or 1.5mm total amplitude, 3 directions, 2h for each, in non-operation
980m/s² (100G), 6ms, 3 directions, 3 times for each, in non-operation
Environment
Mechanical
Shock
Weight
Size (W x H x D)
g
mm
1.5
18 x 4.5 x 11.8
(*1) With nominal input voltage, maximum output current, and Ta=25°C.
(*2) Frequency range in measurement (20MHz). Ripple & noise value is that in the condition where a specified external capacitor (electrolytic capacitor: 15 μ F) is attached
to the output terminal.
(*3) Latch method Resumes by restarting input or resetting remote on/off.
(*4) With Output Off: Level H (Vin-0.6V - Vin or open)
ꢀꢀ In Output On: Level L (0 - Vin-2.5V)
With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
Outline Drawing
Recommended measurements for
Metal case
board mounting
1
2
8
7
8-φ0.8 cut-
through hole
CE-31±1
TDK-Lambda
MADE IN JAPAN
Lot No.
3
4
6
5
18±±.3
15.4
(19.4)
P=2±±.25
Unit: mm
P
P
P
Allowable tolerance is ±0.3 if not
specified separately.
2.9±±.25
2.9±±.25
6±±.25
・All specifications are subject to change without notice.
3
CE-3101
CE-3101 Instruction Manual
1. Explanation of functions
1-1. Connection diagram
1-4. Output voltage setting
[External voltage application system]
Remote
(
)
On/Off
Vout GND 8
1
2
3
4
Output voltage (Vout) can be controlled with external volt-
5V
7
6
NC
C2
age by externally connecting the circuit shown below.
Load
Vin
C1
+
Vset
R1
RA
D1
R2
External voltage
Vset
NC
Vout5
C1
Iout
C1:2.2μF/6.3V
C2:15μF/50V
Vout = [0.5769-(external voltage-0.75)/R2] x 68 + 0.75
Voltage: V Resistance: kΩ
R1/C1: For removing line noise
D1: First-recovery diode
1-2. Terminal connections
No.1
No.2
No.3
No.4
No.5
No.6
No.7
No.8
Control
+Vin
Remote On/Off
Input voltage (4.4-5.5V)
Input (GND)
Note that the external voltage should be within the range of the expression below.
External voltage < R2 x 1mA + 2.5 (unit: V)
ーVin(GND)
NC
+Vout
Vset
Output (40V)
Adjusting output voltage
[Formula of external resistance] (refer to the graph showing
characteristics of the output voltage adjustment):
NC
ーVout(GND)
Output (GND)
Output voltage (Vout) can be controlled by attaching an external resistance
RA between the terminal no. 5 (Vout) and the terminal no. 6 (Vset).
Voltage change is expressed by the following formula.
Vout = 0.5769 x [68 x RA / 69.3 + RA)] + 0.75
Voltage: Vout Resistance: kΩ
・ Terminals no. 3 and 8 are internally connected.
・ Remote On/Off voltage
In H level (Vin: 0.6-Vin or open): Output Off
In L level (0-Vin: 2.5V): Output On
・ Remote On/Off current
150µA max.
Recommended resistance range is 100-1000kΩ.
1-3. Characteristics of the out-
put voltage adjustment
Output voltage (Vout) can be varied as shown in the figure
below by connecting resistance to RA.
1-5. Variable output voltage
function
The internal circuit is configured as shown below.
Vref
=
Characteristics of the output voltage adjustment
Vref 0.75V
8
=
Ra 1.3kΩ
40
Ra
=
Rb 68kΩ
7
38
36
34
32
30
28
26
24
Rb
※R
A
6
5
※RA is used when changing
ꢀoutput voltage by external
ꢀresistance.
Internal circuit
100
200
300 400 500
1000
External resistance RA (kΩ)
・All specifications are subject to change without notice.
4
CE-3101
2. Notes on mounting and handling
● The connection diagram 1-1 represents the standard
connection methods for this product.
Recommended reflow soldering
ꢀ Consult us for use with other connection methods to
avoid failure.
● This product does not operate if input/output capacitors
are not connected.
245
225
● Output may not be started up if an electrolytic capacitor
is used for input. Use a low-impedance input capacitor
(laminated ceramic capacitor is recommended).
● For proper start-up of the converter, the start-up time of
the input voltage should be 40ms or less. (The time af-
ter the input voltage becomes 0.5V until it reaches the
specified input voltage range, should be 40ms or less.)
● Output parallel connection cannot be applied.
● Output series connection cannot be applied.
● Output may not be started up in low current application.
● Do not use this product in an overload condition. Doing
so can cause failure.
180
150
100s max
50s max
Reflow time
・Reflow frequency: 1 time
(mounting on rear panel not allowed)
・Using soldering copper: Within 360°C and 3s
(for product terminals)
・Flow soldering is not allowed.
ꢀ
ꢀ
Preheating temperature:
Soldering temperature:
Solder melting temperature: 225°C or above, within 50s
150°C-180°C, within 100s
245°C or lower
● Input fuse is not installed in this product. Install an input
fuse for safety.
● Connect a fuse for around 3 times the nominal (usual)
input current to the input side.
・All specifications are subject to change without notice.
相关型号:
CE-54-U
Card Edge Connector, 54 Contact(s), 2 Row(s), Straight, 0.1 inch Pitch, Solder Terminal, Locking, Black Insulator,
ADAM-TECH
©2020 ICPDF网 联系我们和版权申明