CHS-ESS-CA5 [TDK]

湿度传感器;
CHS-ESS-CA5
型号: CHS-ESS-CA5
厂家: TDK ELECTRONICS    TDK ELECTRONICS
描述:

湿度传感器

传感器
文件: 总11页 (文件大小:175K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
S E N S O R S  
April 2016  
Humidity Sensor  
CHSSeries  
(2/11)  
S E N S O R S  
Product compatible with RoHS directive  
Humidity Sensor  
Overview of the CHS Series  
APPLICATION  
Refrigerators (The dew condensation prevention),  
air conditioners (indoor humidity control), ,  
PPCs, LBP printers (image quality control),  
industrial electronic humidity sensors, air conditioners for plant factories, etc.  
PRODUCT LINEUP  
Assembly  
Guaranteed  
Type  
Driving range  
measurement  
Accuracy  
Driving Voltage Output voltage  
Shapes  
Dimensions  
accuracy range  
CHS-UPS  
CHS-UPR  
CHS-UGS  
CHS-UGR  
SQUARE TYPE  
ROUND TYPE  
SQUARE TYPE  
ROUND TYPE  
27×11.5×6.5  
ø20×9  
27×11.5×6.5  
ø20×9  
±±3RH  
5 to 95RH  
+25°C  
0 to 1.0V  
5VDC  
5 to 95RH  
±53RH  
±73RH  
0 to +50°C  
20 to 85RH  
CHS-MSS  
SQUARE TYPE  
PCB ASSY  
20×10×5  
+25°C  
50RH  
CHS-CGC5-28  
0 to 2.0V  
19×21×12.6  
+25°C  
Element  
Guaranteed  
Type  
Driving range  
measurement  
accuracy range  
Accuracy  
Driving Voltage Output voltage  
Shapes  
Dimensions  
1k to 80M  
AC5V max.  
5 to 95RH  
50RH  
CHS-ESS-CA5  
±53RH  
SQUARE TYPE  
9.0×6.5×±.7  
0 to +50°C  
+25°C  
(AC1V/1kHz)  
RoHS Directive Compliant Product: See the following for more details related to RoHS Directive compliant products. http://product.tdk.com/en/environment/rohs/  
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.  
Please note that the contents may change without any prior notice due to reasons such as upgrading.  
20160401 / sensor_humidity_chs_en.
(±/11)  
S E N S O R S  
Assembly Sensor units with built-in circuits  
CHS-UPS, -UPR, -UGS, -UGR  
FEATURES  
Guarantee a measurement accuracy of ± ±3 Rꢀ in the humidity range of 5 to 953 Rꢀ.  
They are highly accurate. The nominal accuracy for the CꢀSUPR and CꢀR-UPS is within ± ±(3) Rꢀ.  
Characteristics are stable over a wide temperature range.  
Dry and wet characteristics exhibit virtually no hysteresis.  
ꢀighly cost-effective and compact, requiring extremely little mounting space.  
Low current consumption.  
Outputs DC.1V at 100(3)Rꢀ; relative humidity can be read directly with a voltmeter.  
All-in-one construction integrates sensor with support circuitry. The entire module operates off a 5V power supply.  
SHAPE & DIMENSIONS  
CHS-UGS, -UPS  
6.5max.  
11.5max.  
Sensor  
face  
Sensor  
face  
-
CꢀS UPS  
+
5
V
out  
G
Vout  
GND  
Vcc  
0.49  
Tolerance:±0.2mm  
Dimensions in mm  
2.5  
2.5  
CHS-UGR, -UPR  
20max.  
Sensor  
face  
Label  
Vout  
GND  
Vcc  
5
5
Label  
0.49  
Tolerance:±0.2mm  
Dimensions in mm  
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.  
Please note that the contents may change without any prior notice due to reasons such as upgrading.  
20160401 / sensor_humidity_chs_en.
(4/11)  
S E N S O R S  
Assembly Sensor units with built-in circuits  
CHS-UPS, -UPR, -UGS, -UGR  
MAXIMUM RATINGS (Ta=25°C)  
Power supply voltage Edc  
Operating conditions  
Storage conditions  
7V max.  
0 to +50°C, power supply voltage of 5 V, no dew condensation  
–20 to +60°C, no dew condensation  
TYPICAL ELECTRICAL CHARACTERISTICS  
Item  
Min.  
–±  
–5  
Standard Max.  
Condition  
Edc=5V, 25°C, 5 to 953RH  
Edc=5V, 25°C, 5 to 953RH  
CHS-UPS, -UPR  
CHS-UGS, -UGR  
+±  
+5  
Measurement accuracy(%RH)  
Driving VoltageEdc(V)  
Operating current(mA)  
Output voltage(mV)/%RH  
Output impedance(k)  
Hysteresis(%)RH  
4.75  
5
5.25  
0.6  
Edc=5V, 25°C  
Edc=5V, 25°C, 5 to 953RH  
at DC  
10  
200  
=0  
Stable time: 20min  
Temperature dependency(%RH)  
Response time(min)  
Recommended operating temperature(°C)  
–5  
+5  
+5  
Edc=5V, 25°C standard, +5 to 45°C, 5 to 953RH  
1 Response time to reach 903 of actual humidity from ±0to 853 RH  
Edc=5V, no dew condensation  
1
+45  
Reference value  
Example of sensor linearity characteristics  
CHS-UPS, -UPR  
CHS-UGS, -UGR  
at Edc=5V, Ta=25°C, 53 to 953RH  
at Edc=5V, Ta=25°C, 53 to 953RH  
1
1
0.9  
0.9  
0.8  
0.8  
53RH  
0.7  
±3RH  
0.7  
0.6  
0.5  
0.6  
0.5  
0.4  
0.4  
±3RH  
53RH  
0.±  
0.±  
0.2  
0.1  
0
0.2  
0.1  
0
0
20  
40  
60  
80  
100  
0
20  
40  
60  
80  
100  
Relative humidity (3RH)  
Relative humidity (3RH)  
Example of thermal characteristics(Temperature dependency)  
at Edc=5V, +5 to +45°C, 53 to 953RH  
1
953RH  
903RH  
0.9  
0.8  
0.7  
803RH  
703RH  
603RH  
503RH  
0.6  
0.5  
0.4  
0.±  
0.2  
0.1  
0
403RH  
±03RH  
203RH  
103RH  
53RH  
5
10 15 20 25 ±0 ±5 40 45  
(
)
Temperature °C  
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.  
Please note that the contents may change without any prior notice due to reasons such as upgrading.  
20160401 / sensor_humidity_chs_en.
(5/11)  
S E N S O R S  
Assembly Sensor units with built-in circuits  
CHS-MSS  
FEATURES  
A compact type that is the smallest and lightest in the series.  
Guarantees a measurement accuracy of ± 53 Rꢀ in the humidity range of 20 to 853 Rꢀ.  
Sensor units with built-in circuits that output an Edc of 10 mV per 13 Rꢀ when connected to a 5 V power supply.  
Feature low current consumption (0.6 mA with an operating voltage of 5 V at 25°C).  
Dry and wet characteristics exhibit virtually no hysteresis.  
SHAPE & DIMENSIONS  
10max.  
5max.  
Sensor  
face  
Sensor  
face  
-
CHS MSS  
+
5
Vout  
G
1
2
±
V
GND  
out  
0.25  
0.5  
V
cc  
1
2
±
Tolerance:±0.2mm  
Dimensions in mm  
2.5  
2.5  
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.  
Please note that the contents may change without any prior notice due to reasons such as upgrading.  
20160401 / sensor_humidity_chs_en.
(6/11)  
S E N S O R S  
Assembly Sensor units with built-in circuits  
CHS-MSS  
MAXIMUM RATINGS (Ta=25°C)  
Power supply voltage Edc  
Operating conditions  
Storage conditions  
7V max.  
0 to +50°C, power supply voltage of 5 V, no dew condensation  
–20 to +60°C, no dew condensation  
TYPICAL ELECTRICAL CHARACTERISTICSELECTRICAL CHARACTERISTICS  
Item  
Min.  
Standard Max.  
Condition  
Driving VoltageEdc(V)  
Operating current(mA)  
Output voltage(mV)/%RH  
Output impedance(k)  
Measurement accuracy(%RH)  
Hysteresis(%)RH  
Temperature dependency(%RH)  
Response time(min)  
Recommended operating temperature(°C)  
4.75  
5
5.25  
0.6  
Edc=5V, 25°C  
Edc=5V, 25°C, 20 to 853RH  
at DC  
Edc=5V, 25°C, 20 to 853RH  
Stable time: 20min  
Edc=5V, 25°C standard, +15 to ±5°C, 20 to 853RH  
10  
200  
–5  
+5  
=0  
1
–5  
+5  
1 Response time to reach 903 of actual humidity from ±0to 853 RH  
Edc=5V, no dew condensation  
+15  
+±5  
Reference value  
Example of sensor linearity characteristics  
at Edc=5V, Ta=25°C, 203 to 853RH  
Example of thermal characteristics (Temperature dependency)  
at Edc=5V, +15 to +±5°C, 203 to 853RH  
1
1
0.9  
0.9  
953RH  
903RH  
803RH  
703RH  
0.8  
0.8  
0.7  
0.6  
0.5  
53RH  
0.7  
603RH  
0.6  
0.5  
503RH  
403RH  
±03RH  
203RH  
0.4  
0.4  
0.±  
0.2  
0.1  
0
53RH  
0.±  
0.2  
0.1  
0
103RH  
53RH  
0
20  
40  
60  
80  
100  
5
10 15 20 25 ±0 ±5 40 45  
(
)
Relative humidity (3RH)  
Temperature °C  
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.  
Please note that the contents may change without any prior notice due to reasons such as upgrading.  
20160401 / sensor_humidity_chs_en.
(7/11)  
S E N S O R S  
Assembly Sensor units with built-in circuits  
CHS-CGC5-28  
FEATURES  
A small sensor element and connector are mounted on a PCB on which a circuit is provided.  
Guarantees a measurement accuracy of ± ꢁ3 Rꢀ at a humidity of 50 3 Rꢀ.  
Outputs power suitable to the measured humidity when connected to a 5 V power supply.  
The hysteresis of the dry and wet characteristics is about 13 Rꢀ.  
Equipped with a thermistor for humidity detection.  
SHAPE & DIMENSIONS  
21  
9.5  
4.75  
ø±.5±0.1  
4
±
2
1
4
±
2
1
Thermistor  
GND  
V
out  
V
cc  
(
)
Sensor  
element  
Connector: 292250-4 AMP  
Area without parts and the pattern  
(Installation area)  
Tolerance:±0.5mm  
Dimensions in mm  
BUILT-IN SENSOR (THERMISTOR) CONNECTION EXAMPLE  
Edc  
R
Sensor  
element  
4
V
out  
Detection temperature  
output  
±
2
1
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.  
Please note that the contents may change without any prior notice due to reasons such as upgrading.  
20160401 / sensor_humidity_chs_en.
(8/11)  
S E N S O R S  
Assembly Sensor units with built-in circuits  
CHS-CGC5-28  
MAXIMUM RATINGS (Ta=25°C)  
Power supply voltage Edc  
Operating conditions  
Storage conditions  
7V max.  
0 to +50°C, power supply voltage of 5 V, no dew condensation  
–20 to +60°C, no dew condensation  
TYPICAL ELECTRICAL CHARACTERISTICSELECTRICAL CHARACTERISTICS  
Item  
Min.  
Standard Max.  
Condition  
Driving VoltageEdc(V)  
Operating current(mA)  
Output impedance(k)  
4.75  
5
5.25  
2
Edc=5V, 25°C  
at DC  
100  
–7  
+7  
1.096V  
Measurement accuracy(%RH)  
Edc=5V, 25°C, at 503RH  
0.724V 0.89V  
Hysteresis(%)RH  
Response time(min)  
=0  
1
Stable time: 20min  
1 Response time to reach 903 of actual humidity from ±0to 853 RH  
Reference value  
Example of sensor linearity characteristics  
at Edc=5V, Ta=25°C, 503RH  
Example of thermal characteristics (Temperature dependency)  
at Edc=5V, 25°C, 503RH  
2.2  
2.0  
1.8  
1.6  
1.4  
1.2  
2.2  
903RH  
2.0  
1.8  
1.6  
1.4  
1.2  
1.0  
0.8  
0.6  
0.4  
0.2  
0
803RH  
703RH  
603RH  
503RH  
403RH  
±03RH  
73RH  
1.0  
0.8  
73RH  
0.6  
0.4  
0.2  
0
203RH  
103RH  
0
10 20 ±0 40 50 60 70 80 90 100  
Relative humidity (3RH)  
5
10 15 20 25 ±0 ±5 40 45  
(
)
Temperature °C  
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.  
Please note that the contents may change without any prior notice due to reasons such as upgrading.  
20160401 / sensor_humidity_chs_en.
(9/11)  
S E N S O R S  
Element  
CHS-ESS-CA5  
FEATURES  
A variable resistance humidity sensor with superior water and gas resistance in a small package.  
Features a large impedance change in response to humidity changes and exhibits excellent responsiveness and sensitivity.  
Guarantees a measurement accuracy of ± 53 Rꢀ at a humidity of 50 3 Rꢀ.  
The hysteresis of the dry and wet characteristics is suppressed at about 13 Rꢀ.  
SHAPE & DIMENSIONS  
6.5±0.5  
±.7±0.5  
Sensor  
face  
Sensor  
face  
(
)
(
)
0.25  
0.5  
Tolerance:±0.2mm  
Dimensions in mm  
2.54  
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.  
Please note that the contents may change without any prior notice due to reasons such as upgrading.  
20160401 / sensor_humidity_chs_en.
(10/11)  
S E N S O R S  
Element  
CHS-ESS-CA5  
MAXIMUM RATINGS (Ta=25°C)  
Power supply voltage Edc  
Operating conditions  
Storage conditions  
7V max.  
0 to +60°C, 10 to 903RH, no dew condensation  
–20 to +85°C, 5 to 953RH, no dew condensation  
TYPICAL ELECTRICAL CHARACTERISTICSELECTRICAL CHARACTERISTICS  
Item  
Min.  
Standard Max.  
Condition  
Driving VoltageEdc(V)  
Operating current(mA)  
Output impedance(k)  
5
0.5  
62  
26  
40  
25°C, at 503RH  
–5  
26kꢀ  
+5  
62kꢀ  
Measurement accuracy(%RH)  
Edc=5V, 25°C, at 503RH  
40kꢀ  
Hysteresis(%)RH  
Response time(min)  
1
1
1 Response time to reach 903 of actual humidity from ±0to 853 RH  
Reference value  
Impedance-humidity characteristics (by temperature)  
Impedance-humidity characteristics (by frequency)  
at Edc=1V, 1kHz  
at Edc=1V, 25°C  
100M  
10M  
1M  
100M  
10M  
1M  
100K  
100K  
5˚C  
10K  
1K  
100Hz  
1kHz  
10kHz  
100kHz  
10K  
1K  
15˚C  
25˚C  
±5˚C  
45˚C  
0
10 20 ±0 40 50 60 70 80 90  
Relative humidity (3RH)  
0
10 20 ±0 40 50 60 70 80 90  
Relative humidity (3RH)  
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.  
Please note that the contents may change without any prior notice due to reasons such as upgrading.  
20160401 / sensor_humidity_chs_en.
(11/11)  
S E N S O R S  
CHS Series  
Handling Precautions  
For all CHS Series products  
Please request the delivery specification form containing more detailed information on characteristics and specifications, so as to ensure correct  
and safe use of the products.  
Operating life of the products becomes shorter depending on the environmental conditions. If you place emphasis on the stable operation period, please  
confirm the operating life in the actual environment in advance.  
[Storage Environment]  
Check the standards concerning the storage conditions described in the delivery specifications of the products, and store them in accordance with  
the standards.  
It is recommended that the products be stored in an airtight container with silica gel.  
Avoid storing the products in environments in which corrosive gases are generated, enter, or stagnate, or in dusty environments.  
Storage in high temperature and high-humidity environments, environments where dew condensation occurs, or environments where sudden tem-  
perature changes may cause deterioration of the moisture sensitive film, resulting in fluctuations of output exceeding the guaranteed range. If the  
products have been stored in such environments, check their characteristics before use.  
Storage in environments where products may come into contact with water or saltwater may cause deterioration of the moisture sensitive film,  
resulting in fluctuations of output exceeding the guaranteed range. If the products have been stored in such environments, check their characteris-  
tics before use.  
Storage for an extended period of time may cause deterioration of the moisture sensitive film, resulting in fluctuations of output exceeding the guar-  
anteed range. If the products have been stored for an extended period of time, check their characteristics before use.  
[Usage Environment/Operating Conditions]  
As for operating conditions and operating conditions of the products, check the standards concerning the operating conditions described in the  
delivery specifications, and use the products in accordance with the standards.  
Generation, influx, or stagnation of corrosive gases or a large amount of dust may become a cause of deterioration of the moisture sensitive film,  
resulting in fluctuations of output exceeding the guaranteed range.  
ꢀigh temperature and high humidity, dew condensation, or sudden temperature changes may become a cause of deterioration of the moisture  
sensitive film, resulting in fluctuations of output exceeding the guaranteed range.  
Environments where the products come into contact with water or saltwater may become a cause of deterioration of the moisture sensitive film,  
resulting in fluctuations of output exceeding the guaranteed range.  
[Product Handling]  
Do not apply excessive mechanical shock to the products, such as dropping.  
Do not cover the sensor face of the products when mounting.  
Pay attention not to apply excessive stress on the main unit when forming terminals.  
In processes in which a flux decomposition gas is generated, such as flow soldering, take measures to prevent corrosive gases from entering into  
the product, such as applying a temporary seal on the opening of the main unit (corrosive gases may become a cause of deterioration of the mois-  
ture sensitive film, resulting in fluctuations of output exceeding the guaranteed range).  
Element type  
[Usage Environment/Operating Conditions]  
The rated voltage of this product is Eac 5 V max. Please be reminded that serious damage including electrolysis or peeling of the moisture sensitive mate-  
rial may occur if a direct current is applied to the products. In addition, please keep in mind that there may be similar impacts that occur in the case of  
direct current application will occur even when applying an alternating current, due to (1) residual direct current or (2) asymmetrical waveforms.  
Other Requests/Notices  
We will not assume any responsibility for damage caused by use outside the ranges or conditions defined in the delivery specifications.  
Specifications of the products in this catalog are subject to change without notice, due to improvements or other reasons. In addition, supply of the prod-  
ucts may be canceled without notice.  
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.  
Please note that the contents may change without any prior notice due to reasons such as upgrading.  
20160401 / sensor_humidity_chs_en.

相关型号:

CHS-GR

Analog Circuit, 1 Func
TDK

CHS-GS

Analog Circuit, 1 Func
TDK

CHS-GSS

Analog Circuit, 1 Func,
TDK

CHS-HT0603

High Temperature Chip Resistors
RHOPOINT

CHS-HT0805

High Temperature Chip Resistors
RHOPOINT

CHS-HT1206

High Temperature Chip Resistors
RHOPOINT

CHS-HT1210

High Temperature Chip Resistors
RHOPOINT

CHS-HT2010

High Temperature Chip Resistors
RHOPOINT

CHS-HT2512

High Temperature Chip Resistors
RHOPOINT

CHS-HT4020

High Temperature Chip Resistors
RHOPOINT

CHS-MSS

Analog Circuit, 1 Func,
TDK

CHS-UGR

Analog Circuit, 1 Func,
TDK