CHS-ESS-CA5 [TDK]
湿度传感器;型号: | CHS-ESS-CA5 |
厂家: | TDK ELECTRONICS |
描述: | 湿度传感器 传感器 |
文件: | 总11页 (文件大小:175K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
S E N S O R S
April 2016
Humidity Sensor
CHSSeries
(2/11)
S E N S O R S
Product compatible with RoHS directive
Humidity Sensor
Overview of the CHS Series
APPLICATION
Refrigerators (The dew condensation prevention),
air conditioners (indoor humidity control), ,
PPCs, LBP printers (image quality control),
industrial electronic humidity sensors, air conditioners for plant factories, etc.
PRODUCT LINEUP
Assembly
Guaranteed
Type
Driving range
measurement
Accuracy
Driving Voltage Output voltage
Shapes
Dimensions
accuracy range
CHS-UPS
CHS-UPR
CHS-UGS
CHS-UGR
SQUARE TYPE
ROUND TYPE
SQUARE TYPE
ROUND TYPE
27×11.5×6.5
ø20×9
27×11.5×6.5
ø20×9
±±3RH
5 to 95%RH
+25°C
0 to 1.0V
5VDC
5 to 95%RH
±53RH
±73RH
0 to +50°C
20 to 85%RH
CHS-MSS
SQUARE TYPE
PCB ASSY
20×10×5
+25°C
50%RH
CHS-CGC5-28
0 to 2.0V
19×21×12.6
+25°C
Element
Guaranteed
Type
Driving range
measurement
accuracy range
Accuracy
Driving Voltage Output voltage
Shapes
Dimensions
1k to 80M ꢀ
AC5V max.
5 to 95%RH
50%RH
CHS-ESS-CA5
±53RH
SQUARE TYPE
9.0×6.5×±.7
0 to +50°C
+25°C
(AC1V/1kHz)
RoHS Directive Compliant Product: See the following for more details related to RoHS Directive compliant products. http://product.tdk.com/en/environment/rohs/
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20160401 / sensor_humidity_chs_en.
(±/11)
S E N S O R S
Assembly ・Sensor units with built-in circuits
ꢀ
CHS-UPS, -UPR, -UGS, -UGR
FEATURES
Guarantee a measurement accuracy of ± ±3 Rꢀ in the humidity range of 5 to 953 Rꢀ.
They are highly accurate. The nominal accuracy for the CꢀSUPR and CꢀR-UPS is within ± ±(3) Rꢀ.
Characteristics are stable over a wide temperature range.
Dry and wet characteristics exhibit virtually no hysteresis.
ꢀighly cost-effective and compact, requiring extremely little mounting space.
Low current consumption.
Outputs DC.1V at 100(3)Rꢀ; relative humidity can be read directly with a voltmeter.
All-in-one construction integrates sensor with support circuitry. The entire module operates off a 5V power supply.
SHAPE & DIMENSIONS
CHS-UGS, -UPS
6.5max.
11.5max.
Sensor
face
Sensor
face
-
CꢀS UPS
+
5
V
out
G
① Vout
② GND
③ Vcc
①
②
③
0.49
Tolerance:±0.2mm
Dimensions in mm
2.5
2.5
CHS-UGR, -UPR
20max.
Sensor
face
Label
① Vout
② GND
③ Vcc
①
②
③
5
5
Label
0.49
Tolerance:±0.2mm
Dimensions in mm
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20160401 / sensor_humidity_chs_en.
(4/11)
S E N S O R S
Assembly ・Sensor units with built-in circuits
ꢀ
CHS-UPS, -UPR, -UGS, -UGR
MAXIMUM RATINGS (Ta=25°C)
Power supply voltage Edc
Operating conditions
Storage conditions
7V max.
0 to +50°C, power supply voltage of 5 V, no dew condensation
–20 to +60°C, no dew condensation
TYPICAL ELECTRICAL CHARACTERISTICS
Item
Min.
–±
–5
Standard Max.
Condition
Edc=5V, 25°C, 5 to 953RH
Edc=5V, 25°C, 5 to 953RH
CHS-UPS, -UPR
CHS-UGS, -UGR
+±
+5
Measurement accuracy(%RH)
Driving VoltageEdc(V)
Operating current(mA)
Output voltage(mV)/%RH
Output impedance(kꢀ)
Hysteresis(%)RH
4.75
5
5.25
0.6
Edc=5V, 25°C
Edc=5V, 25°C, 5 to 953RH
at DC
10
200
=0
ꢁ
Stable time: 20min
Temperature dependency(%RH)
Response time(min)
Recommended operating temperature(°C)
–5
+5
+5
Edc=5V, 25°C standard, +5 to 45°C, 5 to 953RH
1 Response time to reach 903 of actual humidity from ±0to 853 RH
Edc=5V, no dew condensation
1
+45
ꢁ
Reference value
Example of sensor linearity characteristics
CHS-UPS, -UPR
CHS-UGS, -UGR
at Edc=5V, Ta=25°C, 53 to 953RH
at Edc=5V, Ta=25°C, 53 to 953RH
1
1
0.9
0.9
0.8
0.8
53RH
0.7
±3RH
0.7
0.6
0.5
0.6
0.5
0.4
0.4
±3RH
53RH
0.±
0.±
0.2
0.1
0
0.2
0.1
0
0
20
40
60
80
100
0
20
40
60
80
100
Relative humidity (3RH)
Relative humidity (3RH)
Example of thermal characteristics(Temperature dependency)
at Edc=5V, +5 to +45°C, 53 to 953RH
1
953RH
903RH
0.9
0.8
0.7
803RH
703RH
603RH
503RH
0.6
0.5
0.4
0.±
0.2
0.1
0
403RH
±03RH
203RH
103RH
53RH
5
10 15 20 25 ±0 ±5 40 45
(
)
Temperature °C
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20160401 / sensor_humidity_chs_en.
(5/11)
S E N S O R S
Assembly ・Sensor units with built-in circuits
CHS-MSS
FEATURES
A compact type that is the smallest and lightest in the series.
Guarantees a measurement accuracy of ± 53 Rꢀ in the humidity range of 20 to 853 Rꢀ.
Sensor units with built-in circuits that output an Edc of 10 mV per 13 Rꢀ when connected to a 5 V power supply.
Feature low current consumption (0.6 mA with an operating voltage of 5 V at 25°C).
Dry and wet characteristics exhibit virtually no hysteresis.
SHAPE & DIMENSIONS
10max.
5max.
Sensor
face
Sensor
face
-
CHS MSS
+
5
Vout
G
1
2
±
V
GND
out
0.25
0.5
V
cc
1
2
±
Tolerance:±0.2mm
Dimensions in mm
2.5
2.5
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20160401 / sensor_humidity_chs_en.
(6/11)
S E N S O R S
Assembly ・Sensor units with built-in circuits
CHS-MSS
MAXIMUM RATINGS (Ta=25°C)
Power supply voltage Edc
Operating conditions
Storage conditions
7V max.
0 to +50°C, power supply voltage of 5 V, no dew condensation
–20 to +60°C, no dew condensation
TYPICAL ELECTRICAL CHARACTERISTICSELECTRICAL CHARACTERISTICS
Item
Min.
Standard Max.
Condition
Driving VoltageEdc(V)
Operating current(mA)
Output voltage(mV)/%RH
Output impedance(kꢀ)
Measurement accuracy(%RH)
Hysteresis(%)RH
Temperature dependency(%RH)
Response time(min)
Recommended operating temperature(°C)
4.75
5
5.25
0.6
Edc=5V, 25°C
Edc=5V, 25°C, 20 to 853RH
at DC
Edc=5V, 25°C, 20 to 853RH
Stable time: 20min
Edc=5V, 25°C standard, +15 to ±5°C, 20 to 853RH
10
200
ꢁ
–5
+5
=0
1
–5
+5
1 Response time to reach 903 of actual humidity from ±0to 853 RH
Edc=5V, no dew condensation
+15
+±5
ꢁ
Reference value
Example of sensor linearity characteristics
at Edc=5V, Ta=25°C, 203 to 853RH
Example of thermal characteristics (Temperature dependency)
at Edc=5V, +15 to +±5°C, 203 to 853RH
1
1
0.9
0.9
953RH
903RH
803RH
703RH
0.8
0.8
0.7
0.6
0.5
53RH
0.7
603RH
0.6
0.5
503RH
403RH
±03RH
203RH
0.4
0.4
0.±
0.2
0.1
0
53RH
0.±
0.2
0.1
0
103RH
53RH
0
20
40
60
80
100
5
10 15 20 25 ±0 ±5 40 45
(
)
Relative humidity (3RH)
Temperature °C
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20160401 / sensor_humidity_chs_en.
(7/11)
S E N S O R S
Assembly ・Sensor units with built-in circuits
CHS-CGC5-28
FEATURES
A small sensor element and connector are mounted on a PCB on which a circuit is provided.
Guarantees a measurement accuracy of ± ꢁ3 Rꢀ at a humidity of 50 3 Rꢀ.
Outputs power suitable to the measured humidity when connected to a 5 V power supply.
The hysteresis of the dry and wet characteristics is about 13 Rꢀ.
Equipped with a thermistor for humidity detection.
SHAPE & DIMENSIONS
21
9.5
4.75
ø±.5±0.1
4
±
2
1
4
±
2
1
Thermistor
GND
V
out
V
cc
(
)
Sensor
element
Connector: 292250-4 AMP
Area without parts and the pattern
(Installation area)
Tolerance:±0.5mm
Dimensions in mm
BUILT-IN SENSOR (THERMISTOR) CONNECTION EXAMPLE
Edc
R
Sensor
element
4
V
out
Detection temperature
output
±
2
1
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20160401 / sensor_humidity_chs_en.
(8/11)
S E N S O R S
Assembly ・Sensor units with built-in circuits
CHS-CGC5-28
MAXIMUM RATINGS (Ta=25°C)
Power supply voltage Edc
Operating conditions
Storage conditions
7V max.
0 to +50°C, power supply voltage of 5 V, no dew condensation
–20 to +60°C, no dew condensation
TYPICAL ELECTRICAL CHARACTERISTICSELECTRICAL CHARACTERISTICS
Item
Min.
Standard Max.
Condition
Driving VoltageEdc(V)
Operating current(mA)
Output impedance(kꢀ)
4.75
5
5.25
2
Edc=5V, 25°C
at DC
ꢁ
100
–7
+7
1.096V
Measurement accuracy(%RH)
Edc=5V, 25°C, at 503RH
0.724V 0.89V
Hysteresis(%)RH
Response time(min)
=0
1
Stable time: 20min
1 Response time to reach 903 of actual humidity from ±0to 853 RH
ꢁ
Reference value
Example of sensor linearity characteristics
at Edc=5V, Ta=25°C, 503RH
Example of thermal characteristics (Temperature dependency)
at Edc=5V, 25°C, 503RH
2.2
2.0
1.8
1.6
1.4
1.2
2.2
903RH
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
803RH
703RH
603RH
503RH
403RH
±03RH
73RH
1.0
0.8
73RH
0.6
0.4
0.2
0
203RH
103RH
0
10 20 ±0 40 50 60 70 80 90 100
Relative humidity (3RH)
5
10 15 20 25 ±0 ±5 40 45
(
)
Temperature °C
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20160401 / sensor_humidity_chs_en.
(9/11)
S E N S O R S
Element
CHS-ESS-CA5
FEATURES
A variable resistance humidity sensor with superior water and gas resistance in a small package.
Features a large impedance change in response to humidity changes and exhibits excellent responsiveness and sensitivity.
Guarantees a measurement accuracy of ± 53 Rꢀ at a humidity of 50 3 Rꢀ.
The hysteresis of the dry and wet characteristics is suppressed at about 13 Rꢀ.
SHAPE & DIMENSIONS
6.5±0.5
±.7±0.5
Sensor
face
Sensor
face
(
)
(
)
0.25
0.5
Tolerance:±0.2mm
Dimensions in mm
2.54
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20160401 / sensor_humidity_chs_en.
(10/11)
S E N S O R S
Element
CHS-ESS-CA5
MAXIMUM RATINGS (Ta=25°C)
Power supply voltage Edc
Operating conditions
Storage conditions
7V max.
0 to +60°C, 10 to 903RH, no dew condensation
–20 to +85°C, 5 to 953RH, no dew condensation
TYPICAL ELECTRICAL CHARACTERISTICSELECTRICAL CHARACTERISTICS
Item
Min.
Standard Max.
Condition
Driving VoltageEdc(V)
Operating current(mA)
Output impedance(kꢀ)
5
0.5
62
26
40
25°C, at 503RH
–5
26kꢀ
+5
62kꢀ
Measurement accuracy(%RH)
Edc=5V, 25°C, at 503RH
40kꢀ
Hysteresis(%)RH
Response time(min)
1
1
1 Response time to reach 903 of actual humidity from ±0to 853 RH
ꢁ
Reference value
Impedance-humidity characteristics (by temperature)
Impedance-humidity characteristics (by frequency)
at Edc=1V, 1kHz
at Edc=1V, 25°C
100M
10M
1M
100M
10M
1M
100K
100K
5˚C
10K
1K
100Hz
1kHz
10kHz
100kHz
10K
1K
15˚C
25˚C
±5˚C
45˚C
0
10 20 ±0 40 50 60 70 80 90
Relative humidity (3RH)
0
10 20 ±0 40 50 60 70 80 90
Relative humidity (3RH)
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20160401 / sensor_humidity_chs_en.
(11/11)
S E N S O R S
CHS Series
Handling Precautions
For all CHS Series products
Please request the delivery specification form containing more detailed information on characteristics and specifications, so as to ensure correct
and safe use of the products.
Operating life of the products becomes shorter depending on the environmental conditions. If you place emphasis on the stable operation period, please
confirm the operating life in the actual environment in advance.
[Storage Environment]
Check the standards concerning the storage conditions described in the delivery specifications of the products, and store them in accordance with
the standards.
It is recommended that the products be stored in an airtight container with silica gel.
Avoid storing the products in environments in which corrosive gases are generated, enter, or stagnate, or in dusty environments.
Storage in high temperature and high-humidity environments, environments where dew condensation occurs, or environments where sudden tem-
perature changes may cause deterioration of the moisture sensitive film, resulting in fluctuations of output exceeding the guaranteed range. If the
products have been stored in such environments, check their characteristics before use.
Storage in environments where products may come into contact with water or saltwater may cause deterioration of the moisture sensitive film,
resulting in fluctuations of output exceeding the guaranteed range. If the products have been stored in such environments, check their characteris-
tics before use.
Storage for an extended period of time may cause deterioration of the moisture sensitive film, resulting in fluctuations of output exceeding the guar-
anteed range. If the products have been stored for an extended period of time, check their characteristics before use.
[Usage Environment/Operating Conditions]
As for operating conditions and operating conditions of the products, check the standards concerning the operating conditions described in the
delivery specifications, and use the products in accordance with the standards.
Generation, influx, or stagnation of corrosive gases or a large amount of dust may become a cause of deterioration of the moisture sensitive film,
resulting in fluctuations of output exceeding the guaranteed range.
ꢀigh temperature and high humidity, dew condensation, or sudden temperature changes may become a cause of deterioration of the moisture
sensitive film, resulting in fluctuations of output exceeding the guaranteed range.
Environments where the products come into contact with water or saltwater may become a cause of deterioration of the moisture sensitive film,
resulting in fluctuations of output exceeding the guaranteed range.
[Product Handling]
Do not apply excessive mechanical shock to the products, such as dropping.
Do not cover the sensor face of the products when mounting.
Pay attention not to apply excessive stress on the main unit when forming terminals.
In processes in which a flux decomposition gas is generated, such as flow soldering, take measures to prevent corrosive gases from entering into
the product, such as applying a temporary seal on the opening of the main unit (corrosive gases may become a cause of deterioration of the mois-
ture sensitive film, resulting in fluctuations of output exceeding the guaranteed range).
Element type
[Usage Environment/Operating Conditions]
The rated voltage of this product is Eac 5 V max. Please be reminded that serious damage including electrolysis or peeling of the moisture sensitive mate-
rial may occur if a direct current is applied to the products. In addition, please keep in mind that there may be similar impacts that occur in the case of
direct current application will occur even when applying an alternating current, due to (1) residual direct current or (2) asymmetrical waveforms.
Other Requests/Notices
We will not assume any responsibility for damage caused by use outside the ranges or conditions defined in the delivery specifications.
Specifications of the products in this catalog are subject to change without notice, due to improvements or other reasons. In addition, supply of the prod-
ucts may be canceled without notice.
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
20160401 / sensor_humidity_chs_en.