DRB120/240-3 Series
https://product.tdk.com/en/power/drb
https://www.emea.lambda.tdk.com/uk/products/drb-3-phase-series
120W - 240W DIN Rail Mount
Three Phase Power Supplies
The DRB120/240-3 series supports the growing trend for simple and economically priced 3-phase input DIN power supplies for industrial and process control
applications. The series combines low cost, reliability and compact dimensions with energy saving efficiencies of up to 94%. Conservatively rated electrolytic
capacitor temperatures offer improved field life-times of typically 10 years. Available in two power levels, 120W and 240W, the series provides a choice of
12V, 24V and 48V outputs. All models can provide a peak power of 120% for up to 2s to handle capacitive loading. A low energy inrush current level avoids
nuisance tripping of circuit breakers. Units can be connected in parallel to provide more power or for redundant applications. A DC Good relay, remote on/off
and a choice of models with either screw or push-in wire terminals.
Features
Benefits
• High Efficiency, up to 94%
• Lowers Operating Costs and Improves Thermal Performance
• Occupies Less Space on the DIN rail
• Reduced Electrical Noise in the System
• Improved Field Life
• Narrow Case Widths
• Curve B Radiated and Conducted EMI
• Long E-Capacitor Life (typically 10 Years)
• Low Off-Load Power Consumption
• Saves Energy
Model Selector
Output
Voltage
(V)
Adjustment
Range
(V)
Maximum
Current
(A)
Peak
Current
(A) (<2s)
Maximum
Power
(W)
Maximum
Peak
Power (W)
Efficiency
(%)
Model
Terminal
Type
(400/500Vac) (1)
DRB120-12-3-A0
DRB120-12-3-A1
DRB120-24-3-A0
DRB120-24-3-A1
DRB240-24-3-A0
DRB240-24-3-A1
DRB240-48-3-A0
DRB240-48-3-A1
12
12
24
24
24
24
48
48
11.4 - 15
11.4 - 15
22.5 - 29
22.5 - 29
22.5 - 29
22.5 - 29
45 - 56
10
10
5
12
12
6
120
120
120
120
240
240
240
240
144
144
144
144
288
288
288
288
Screw
Push-in
Screw
Push-in
Screw
Push-in
Screw
Push-in
89.4 / 89.1
89.4 / 89.1
91.3 / 91.2
91.3 / 91.2
93.1 / 93.2
93.1 / 93.2
93.8 / 94.0
93.8 / 94.0
5
6
10
10
5
12
12
6
45 - 56
5
6
Related Products
Type
Part Number(s)
Description
Redundancy module
DRM40
DBM20
20 to 40A DIN rail Redundancy module
20A DIN rail Buffer (hold-up) modules
Buffer DIN rail modules
Low power DIN rail power supplies
Mid power DIN rail power supplies
DRB15, 30, 50, 100
DRB120, 240, 480
DRF120, 240, 480, 960
RTMN
15 to 100W AC-DC single phase DIN rail power supplies
120 to 480W AC-DC single phase DIN rail power supplies
120 to 960W AC-DC single phase DIN rail power supplies
6A to 60A 500Vac three phase 2 stage filters with pulse attenuation
Mid to high power premium DIN rail power supplies
DIN rail mount filters
1
DRB120/240-3 Series
Specifications
Model
DRB120-12-3-Ax
DRB120-24-3-Ax
DRB240-24-3-Ax
DRB240-48-3-Ax
Input
Input Voltage Range
Vac
Hz
A
3-phase 350 - 575
47 - 63
Input Frequency
Input Current (Per Phase Max)
Inrush Current (Cold Start 400 / 500Vac )
Dropped Phase Output Power
Leakage Current (575Vac, 60Hz)
Touch Current (575Vac, 60Hz)
Power Factor (400/500Vac)
Harmonic Compliance
0.5
0.5
0.8
0.8
A
30 / 40
30 / 39
36 / 40
34 / 49
W
mA
uA
-
Full load operating on 2 phases. See technical datasheet for conditions
<1
<50
>0.5
>0.6
-
Meets EN61000-3-2 Class A
No Load Power Consumption
Hold Up Time (minimum) at 400 / 500Vac
Efficiency
W
ms
-
1.7
1.7
1.6
1.9
21 / 41
23 / 43
22 / 44
23 / 46
See model selector table
Average Efficiency (400 / 500Vac) (2)
Conducted & Radiated EMI
Immunity
%
-
87.5 / 87.3
89.8 / 88.9
92.5 / 92.1
93.0 / 92.6
EN55011-B, CISPR11-B
See immunity table
IEC/EN/UL/CSA 61010-1, 61010-2-201, 62368-1, IEC 60950-1,
-
Safety Certifications and Markings
-
EN 60204-1, IEC/EN 62477-1, 61204-7, 61558-2-16, CE Mark and UKCA Mark
Immunity
Test
ESD
Standard
EN61000-4-2
Test Level Criteria
See immunity report
See immunity report
A
A
4kV contact 8kV air discharge
10V/m: 80MHz to 1GHz
3V/m 1.4GHz to 2GHz
1V/m 2GHz to 2.7GHz
Input 4kV 5kHz
Radiated Susceptibility
EN61000-4-3
EN61000-4-4
Electrical Fast Transient Burst
See immunity report
See immunity report
A
A
Output 2kV 5kHz
Signal contact 2kV 5kHz
Input symmetrical (L-L) 2kV
Input asymmetrical (L-PE) 4kV
Output symmetrical (L-L) 0.5kV
Output asymmetrical (L-PE) 1kV
150kHz to 80MHz
Surge
EN61000-4-5
Conducted Susceptibility
Magnetic Fields
EN61000-4-6
EN61000-4-8
EN61000-4-11
10V
30A/m
500ms
200ms
20ms
A
A
A
A
A
C
50Hz, 60s each axis (x, y, z)
400Vac at 70%, 50Hz
Voltage Dips and
400Vac at 40%, 50Hz
Input Interruptions
EN61000-4-34
400Vac at 0%, 50Hz
5000ms
400Vac at 0%, 50Hz
2
DRB120/240-3 Series
Specifications
Model
DRB120-12-3-Ax
DRB120-24-3-Ax
DRB240-24-3-Ax
DRB240-48-3-Ax
Output
Output Voltage Tolerance (100% load)
Switching Frequency (Output Converter)
Line Regulation
%
kHz
%
%
%
mV
mV
-
± 3 maximum
50 to 135. (Variable with input line and output load)
< 0.1
Load Regulation (No Parallel Mode)
Load Regulation (Parallel Mode)
Ripple & Noise (+25 to 70oC ambient)
Ripple & Noise (-25 to <+25oC ambient)
Minimum Load
< 1.1
< 3.8
10
< 0.4
< 2.9
10
< 0.6
< 3.1
10
< 0.2
< 2.8
20
20
30
40
80
No minimum load required
Maximum Load Capacitance
Overcurrent Protection (Auto Recovery)
Overvoltage Protection (Auto Recovery)
Overtemperature Protection
Remote Sense
uF
%
V
10,000
< 145
< 18
5,000
< 150
< 32
10,000
< 150
< 32
5,000
< 150
< 58
-
Yes. Auto recovery
-
None
Remote On/Off
-
Closed contact or <4V enables output
Closed contact relay when output voltage is >95%
Green LED indicates DC is OK
DC Good
-
Indicators
-
Parallel Operation
-
Front panel DIP switch to enable parallel droop mode current sharing.
Refer to technical datasheet when paralleling.
Environmental
Operating Temperature Nominal
°C
-25 to +55 full load, up to 70 with derating (see derating below)
Operating Temperature DeratingAbove 55°C W/°C
2
0.8
2.4
2.6
Storage Temperature
Humidity (Non condensing)
Cooling
°C
-40 to +85
%RH
95 (Operating & Storage)
Convection
-
m
Vac
-
Altitude
3,000 nominal, (6,000 maximum no UL certification)
Input to Output 3,510, Input to GND 2,210, Output to GND and signals 1,390
IEC 60068-2-6: 2g / 10 to 500Hz, 1 hour/direction X,Y,Z on DIN rail
IEC 60068-2-27, 30g / 11ms ±5ms, 3 x each axis on DIN rail
Withstand Voltage (For 1 minute)
Vibration (Non operating)
Shock (Non operating)
Other
-
Weight (Typ)
g
mm
Inches
-
660
660
780
780
Size (WxHxD)
55 x 129 x 138.2
2.17 x 5.08 x 5.44
Aluminum
Size (WxHxD)
Case Material
DIN Rail Type
-
Suitable for mounting on TS-35/7.5 or TS35/15 DIN Rails
MTBF - Telcordia SR-332 issue 4*
Warranty
Hours
Years
1,100,000
3
Notes
See website for detailed specifications, test methods and installation manual
(1) Minimum at 100% load
(2) Weighted average: 10%@Pout=20%, 50%@Pout=50%, 20%@Pout=80%, 20%@Pout=100%
*25°C ambient, full load.
3
DRB120/240-3 Series
Outline DRB-3 Screw Terminals (-A0 suffix)
41
16.3mm
(
/64in)
22.4mm(7/
8in)
DRB240-24-3-A0
19
6.5mm (1/
4in)
124mm (47/
8in)
7.45mm
(
/64in)
40.1mm (137
/64in)
135.67mm (511
/
32in)
55mm (211
/64in)
DIN-Rail depth
Outline DRB-3 Push In Terminals (-A1 suffix)
59
15.8mm (5/
8in)
23.4mm
(
/
64in)
DRB240-24-3-A1
23
27
9mm
(
/
64in)
124mm (47/
8
in)
10.6mm
(
/
64in)
33.8mm(121
55mm (211
/64in)
138.2mm (57/16in)
/
64in)
DIN Rail depth
4
DRB120/240-3 Series
TDK-Lambda France SAS
TDK-Lambda Americas
Tel: +33 1 60 12 71 65
Tel: +1 800-LAMBDA-4 or 1-800-526-2324
tla.powersolutions@tdk.com
www.us.lambda.tdk.com
tlf.fr.powersolutions@tdk.com
www.emea.lambda.tdk.com/fr
Italy Sales Office
Tel: +39 02 61 29 38 63
tlf.it.powersolutions@tdk.com
www.emea.lambda.tdk.com/it
TDK Electronics do Brasil Ltda
Tel: +55 11 3289-9599
sales.br@tdk-electronics.tdk.com
www.tdk-electronics.tdk.com/en
Netherlands
tlf.nl.powersolutions@tdk.com
www.emea.lambda.tdk.com/nl
TDK-Lambda Germany GmbH
Tel: +49 7841 666 0
tlg.powersolutions@tdk.com
TDK-Lambda Corporation
Tel: +81-3-6778-1113
www.jp.lambda.tdk.com
www.emea.lambda.tdk.com/de
TDK-Lambda (China) Electronics Co. Ltd.
Tel: +86 21 6485-0777
tlc.powersolutions@tdk.com
www.lambda.tdk.com.cn
Austria Sales Office
Tel: +43 2256 655 84
tlg.at.powersolutions@tdk.com
TDK-Lambda Singapore Pte Ltd.
Tel: +65 6251 7211
tls.marketing@tdk.com
www.sg.lambda.tdk.com
www.emea.lambda.tdk.com/at
Switzerland Sales Office
Tel: +41 44 850 53 53
tlg.ch.powersolutions@tdk.com
www.emea.lambda.tdk.com/ch
TDK India Private Limited, Power Supply Division
Tel: +91 80 4039-0660
mathew.philip@tdk.com
www.sg.lambda.tdk.com
Nordic Sales Office
Tel: +45 8853 8086
tlg.dk.powersolutions@tdk.com
www.emea.lambda.tdk.com/dk
TDK-Lambda UK Ltd.
Tel: +44 (0) 12 71 85 66 66
tlu.powersolutions@tdk.com
www.emea.lambda.tdk.com/uk
TDK-Lambda Ltd.
Tel: +9 723 902 4333
tli.powersolutions@tdk.com
www.emea.lambda.tdk.com/il-en
For Additional Information, please visit
https://product.tdk.com/en/power/
DRB120/240-3_Datasheet_ 260816 October 25th, 2022 v2
5
DRB120/240-3 Series
相关型号:
DRB35H
Rating at 25â Ambient temp. Unless otherwise specified. Single phase, half sine wave, 60HZ,resistive or inductive load.
GXELECTRONICS
DRB35L
Rating at 25â Ambient temp. Unless otherwise specified. Single phase, half sine wave, 60HZ,resistive or inductive load.
GXELECTRONICS
DRB35M
Rating at 25â Ambient temp. Unless otherwise specified. Single phase, half sine wave, 60HZ,resistive or inductive load.
GXELECTRONICS
©2020 ICPDF网 联系我们和版权申明