ECX-001, -003, -005, -007 Series
Power Supplies
AC Input
Multi Output, General-Purpose
FEATURES
• Switches between AC.100/200V.
• 5V and 24V outputs are isolated from one another.
• Increased peak current for 24V output.
• Outstanding for pulse load, mechanical drive applications.
• Small and light weight.
PART NUMBERS AND RATINGS
Output current(A)
5V
Maximum output power(W)
[Peak]
Part No.
24V
24V peak[10s min.]
ECX-001
ECX-003
ECX-005
ECX-007
29[41]
0 to 1
0 to 1.5
0 to 2
0 to 1
0 to 1.5
0 to 3
0 to 6
1.5
3
5
43.5[79.5]
82[130]
159[255]
0 to 3
10
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
ECX-001, -003, -005, -007 Series
Power Supplies
AC Input
Multi Output, General-Purpose
SPECIFICATIONS
29W TYPE(Peak current output: 41W)
Open frame type
Terminal strip:ECX-001A /Vertical connector:ECX-001B/Lateral connector: ECX-001C
L-shape frame type Terminal strip:ECX-001D/Vertical connector:ECX-001E/Lateral connector: ECX-001F
ECX-001A is a standard product. Other items are special order products.
Part No.
ECX-001
V1
V2
W
5V • 1A
24V • 1A[Peak current 1.5A]
29[Peak current output:41]
1
Output voltage, current
Maximum output power
Input requirements
2
Input voltage Eac
V
85 to 115[Rating:100](The input range of 170 to 253V[Rating: 200] is possible by internal switching.)
Input frequency
Input current
Fuse rating
Hz
A
A
47 to 66[Single phase]
1max.[25°C, input and output ratings]
3[Internal]
3
Surge current
A
mA
%
50max.[25°C, cold start]
1max.[25°C, input and output ratings]
75typ.
Leakage current
Efficiency
Output characteristics
Output voltage
Voltage variable range
Maximum output current
Minimum output current
V
V
A
A
5[V1]
Fixed
1
24[V2]
Fixed
1[Peak current 1.5A, 10s max.]
0
0
Input variation %
±1max.
±3.5max.
[Within the input
Load
variation
%
±2max.
±1max.
±5max.
±2max.
voltage range
V2:10 5 to 100%
0 to +40°C]
4
Total variation ±5max.(24V:±10max.)
Voltage
stability
Temperature
variation
Drift
%
%
±0.5max.
—
±1.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±2.4(Voltage variation)/5(Reset time)[0.1 to 1.5A sudden load change]
Dynamic load V/ms
6
Ripple Ep-p
mV
mV
s
100max.
150max.
1.5max.[Rise time: 20ms max.]
20min.
600max.
800max.
6
Ripple noise Ep-p
Start up time
Hold up time
Normal temperature, input and output ratings, load capacitance
100µF max.
ms
Accessory equipment
Operation indicator
None
V1, V2 protected by built-in overvoltage prevention switch inhibition. Recovery when input reset(restart requires
roughly 5min wait).
V1 alone uses voltage lowering. V2 entirely shuts off output upon overcurrent detection or signal lamp
operation(restart requires roughly 5min wait).
Overvoltage protection
Overcurrent protection
7
Remote ON-OFF
Remote sensing
Current balance
Standards
None
None
None
Safety standards
Noise terminal voltage
Construction
—
—
External dimensions
H×W×L
Weight
mm
g
Open frame type 24×93×119
L-shape frame type 25×95×120
300max.
Mounting method
Case material
Input and output cables
Can be attached to 2 sides(Without frame type can be attached to 1 side).
Without cover(With frame also available)
—
1 Rated output current was determined at 40°C. Use 75% load derating at 50°C, 50% load derating at 60°C.
V2 peak current should occur within a less than 10s time interval. Effective current should be kept below the current rating.
2 The product is shipped set for 200V input. For use of the product with 100V input, attach the input voltage switching connector.
3 A power thermistor is used as the current surge control element.
4 Determined for 10 to 100% load variation range.
5 V2 output voltage becomes 30V max. when V2 output drops below 10%.
6 Ripple and noise were determined at 0 to +40°C and rated input and output conditions.
7 Output overcurrent protection is only effective during a short.
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
ECX-001, -003, -005, -007 Series
Power Supplies
AC Input
Multi Output, General-Purpose
SPECIFICATIONS
43.5W TYPE(Peak current output: 79.5W)
Open frame type
Terminal strip:ECX-003A /Vertical connector:ECX-003B/Lateral connector: ECX-003C
L-shape frame type Terminal strip:ECX-003D/Vertical connector:ECX-003E/Lateral connector: ECX-003F
ECX-003A is a standard product. Other items are special order products.
Part No.
ECX-003
V1
V2
W
5V • 1.5A
24V • 1.5A[Peak current 3A]
43.5[Peak current output:79.5]
1
Output voltage, current
Maximum output power
Input requirements
2
Input voltage Eac
V
85 to 115[Rating:100](The input range of 170 to 253V[Rating: 200] is possible by internal switching.)
Input frequency
Input current
Fuse rating
Hz
A
A
47 to 66[Single phase]
1.5max.[25°C, input and output ratings]
3[Internal]
3
Surge current
A
mA
%
50max.[25°C, cold start]
1max.[25°C, input and output ratings]
77typ.
Leakage current
Efficiency
Output characteristics
Output voltage
Voltage variable range
Maximum output current
Minimum output current
V
V
A
A
5[V1]
Fixed
1.5
24[V2]
Fixed
1.5[Peak current 3A, 10s max.]
0
0
Input variation %
±1max.
±3.5max.
[Within the input
Load
variation
%
±2max.
±1max.
±5max.
±2max.
voltage range
V2:10 5 to 100%
0 to +40°C]
4
Total variation ±5max.(24V:±10max.)
Voltage
stability
Temperature
variation
Drift
%
%
±0.5max.
—
±1.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±2.4(Voltage variation)/5(Reset time)[0.3 to 3A sudden load change]
Dynamic load V/ms
6
Ripple Ep-p
mV
mV
s
100max.
150max.
1.5max.[Rise time: 20ms max.]
20min.
600max.
800max.
6
Ripple noise Ep-p
Start up time
Hold up time
Normal temperature, input and output ratings, load capacitance
100µF max.
ms
Accessory equipment
Operation indicator
None
V1, V2 protected by built-in overvoltage prevention switch inhibition. Recovery when input reset(restart requires
roughly 5min wait).
V1 alone uses voltage lowering. V2 entirely shuts off output upon overcurrent detection or signal lamp
operation(restart requires roughly 5min wait).
Overvoltage protection
Overcurrent protection
7
Remote ON-OFF
Remote sensing
Current balance
Standards
None
None
None
Safety standards
Noise terminal voltage
Construction
—
—
External dimensions
H×W×L
Weight
mm
g
Open frame type 29×93×129
L-shape frame type 30×95×130
400max.
Mounting method
Case material
Input and output cables
Can be attached to 2 sides(Without frame type can be attached to 1 side).
Without cover(With frame also available)
—
1 Rated output current was determined at 40°C. Use 75% load derating at 50°C, 50% load derating at 60°C.
V2 peak current should occur within a less than 10s time interval. Effective current should be kept below the current rating.
2 The product is shipped set for 200V input. For use of the product with 100V input, attach the input voltage switching connector.
3 A power thermistor is used as the current surge control element.
4 Determined for 10 to 100% load variation range.
5 V2 output voltage becomes 30V max. when V2 output drops below 10%.
6 Ripple and noise were determined at 0 to +40°C and rated input and output conditions.
7 Output overcurrent protection is only effective during a short.
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
ECX-001, -003, -005, -007 Series
Power Supplies
AC Input
Multi Output, General-Purpose
SPECIFICATIONS
82W TYPE(Peak current output: 130W)
L-shape frame type Terminal strip:ECX-005D /Vertical connector:ECX-005E/Lateral connector: ECX-005F
ECX-005D is a standard product. Other items are special order products.
Part No.
ECX-005
V1
V2
W
5V • 2A
24V • 3A[Peak current 5A]
82[Peak current output:130]
1
Output voltage, current
Maximum output power
Input requirements
2
Input voltage Eac
V
85 to 115[Rating:100](The input range of 170 to 253V[Rating: 200] is possible by internal switching.)
Input frequency
Input current
Fuse rating
Hz
A
A
47 to 66[Single phase]
2.5max.[25°C, input and output ratings]
5[Internal]
3
Surge current
A
mA
%
50max.[25°C, cold start]
1max.[25°C, input and output ratings]
82typ.
Leakage current
Efficiency
Output characteristics
Output voltage
Voltage variable range
Maximum output current
Minimum output current
V
V
A
A
5[V1]
Fixed
2
24[V2]
Fixed
3[Peak current 5A, 10s max.]
0
0
Input variation %
±1max.
±3.5max.
[Within the input
Load
variation
%
±2max.
±1max.
±8max.
±2max.
voltage range
V2:10 5 to 100%
0 to +40°C]
4
Total variation ±5max.(24V:±10max.)
Voltage
stability
Temperature
variation
Drift
%
%
±0.5max.
—
±1.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±2.4(Voltage variation)/5(Reset time)[0.5 to 5A sudden load change]
Dynamic load V/ms
6
Ripple Ep-p
mV
mV
s
100max.
150max.
1.5max.[Rise time: 20ms max.]
20min.
600max.
800max.
6
Ripple noise Ep-p
Start up time
Hold up time
Normal temperature, input and output ratings, load capacitance
100µF max.
ms
Accessory equipment
Operation indicator
None
Only V1 protected by built-in overvoltage prevention switch inhibition. Recovery when input reset(restart
requires roughly 5min wait).
Overvoltage protection
7
Overcurrent protection
Remote ON-OFF
Remote sensing
Current balance
Standards
Entirely shuts off output upon overcurrent detection(load shorted) or signal lamp operation.
None
None
None
Safety standards
Noise terminal voltage
Construction
—
—
External dimensions
H×W×L
Weight
mm
g
30×95×160
500max.
Mounting method
Case material
Input and output cables
Can be attached to 2 sides.
Without cover(With frame)
—
1 Rated output current was determined at 40°C. Use 75% load derating at 50°C, 50% load derating at 60°C.
V2 peak current should occur within a less than 10s time interval. Effective current should be kept below the current rating.
2 The product is shipped set for 200V input. For use of the product with 100V input, attach the input voltage switching connector.
3 A power thermistor is used as the current surge control element.
4 Determined for 10 to 100% load variation range.
5 V2 output voltage becomes 30V max. when V2 output drops below 10%.
6 Ripple and noise were determined at 0 to +40°C and rated input and output conditions.
7 Output overcurrent protection is only effective during a short.
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
ECX-001, -003, -005, -007 Series
Power Supplies
AC Input
Multi Output, General-Purpose
SPECIFICATIONS
159W TYPE(Peak current output: 255W)
L-shape frame type Terminal strip:ECX-007D /Vertical connector:ECX-007E/Lateral connector: ECX-007F
ECX-007D is a standard product. Other items are special order products.
Part No.
ECX-007
V1
V2
W
5V • 3A
24V • 6A[Peak current 10A]
159[Peak current output:255]
1
Output voltage, current
Maximum output power
Input requirements
2
Input voltage Eac
V
85 to 115[Rating:100](The input range of 170 to 253V[Rating: 200] is possible by internal switching.)
Input frequency
Input current
Fuse rating
Hz
A
A
47 to 66[Single phase]
5max.[25°C, input and output ratings]
8[Internal]
3
Surge current
A
50max.[25°C, input and output ratings, 1st surge current reset after roughly 30s min.]
Leakage current
Efficiency
mA
%
1max.[25°C, input and output ratings]
85typ.
Output characteristics
Output voltage
Voltage variable range
Maximum output current
Minimum output current
V
V
A
A
5[V1]
Fixed
3
24[V2]
Fixed
6[Peak current 10A, 10s max.]
0
0
Input variation %
±1max.
±3.5max.
[Within the input
Load
variation
%
±2max.
±1max.
±8max.
±2max.
voltage range
V2:10 4 to 100%
0 to +40°C]
3
Total variation ±5max.(24V:±10max.)
Voltage
stability
Temperature
variation
Drift
%
%
±0.5max.
—
±1.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
±2.4(Voltage variation)/5(Reset time)[1 to 10A sudden load change]
Dynamic load V/ms
5
Ripple Ep-p
mV
mV
s
100max.
150max.
1.5max.[Rise time: 20ms max.]
20min.
600max.
800max.
5
Ripple noise Ep-p
Start up time
Hold up time
Normal temperature, input and output ratings, load capacitance
100µF max.
ms
Accessory equipment
Operation indicator
None
Only V1 protected by built-in overvoltage prevention switch inhibition. Recovery when input reset(restart
requires roughly 5min wait).
Overvoltage protection
6
Overcurrent protection
Remote ON-OFF
Remote sensing
Current balance
Standards
Entirely shuts off output upon overcurrent detection(load shorted) or signal lamp operation.
None
None
None
Safety standards
Noise terminal voltage
Construction
—
—
External dimensions
H×W×L
Weight
mm
g
35×95×220
700max.
Mounting method
Case material
Input and output cables
Can be attached to 2 sides.
Without cover(With frame)
—
1 Rated output current was determined at 40°C. Use 75% load derating at 50°C, 50% load derating at 60°C.
V2 peak current should occur within a less than 10s time interval. Effective current should be kept below the current rating.
2 The product is shipped set for 200V input. For use of the product with 100V input, attach the input voltage switching connector.
3 Determined for 10 to 100% load variation range.
4 V2 output voltage becomes 30V max. when V2 output drops below 10%.
5 Ripple and noise were determined at 0 to +40°C and rated input and output conditions.
6 Output overcurrent protection is only effective during a short.
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
ECX-001, -003, -005, -007 Series
Power Supplies
AC Input
Multi Output, General-Purpose
TERMINAL DESIGNATIONS AND FUNCTIONS
ECX-001
Terminal No. 1: AC input terminals(L, N)
1
2
3
4
5
6
7
1
3
5
24V+
24V+
24V–
NC
Connect to AC.100 or 200V single
phase power lines. The product is
shipped set for AC.200V input. If
AC.100V power supply is to be used,
attach the input voltage switching
connector to CP2.
4
5
3
+
(
)
Ref.
1
24V
5V
4
2
3
4
5
6
7
4
5
3
Housing
XHP-7 JST
Adapter contact
SXH-001T-P0.6
–
+
–
(
)
5V+
5V–
5V–
G
Terminal No. 2: Ground terminal(G)
Connect to earth ground.
3
2
1
Terminal No. 3: DC output terminals(5V,
+, –)
1
3
5
2
1
G
L
Connect to load.
(
)
Ref.
2
1
Terminal No. 4: DC output terminals
(24V, +, –)
Housing
VHR5N JST
Adapter contact
SVH-21T-P1.1
L
(
)
N
Connect to load.
N
CP2
Terminal No. 5: Not connected(NC)
Do not connect. This should not be
used.
6
Terminal No. 6: Input voltage switching
connector(CP2)
This is used for switching between
input AC voltages.
No CP2 connector: 200V input
CP2 connector in place:100V input
ECX-003, 005
Terminal No. 1: AC input terminals(L, N)
Connect to AC.100 or 200V single
phase power lines. The product is
shipped set for AC.200V input. If
AC.100V power supply is to be used,
attach the input voltage switching
connector to CP2.
24V+
24V+
24V–
5V+
5V–
5V–
G
1
4
2
3
4
5
6
1
3
5
(
)
Ref.
+
–
+
–
1
Housing
VHR-6N JST
Adapter contact
SXH-21T-P1.1
24V
5V
4
2
3
4
5
6
4
3
(
)
3
Terminal No. 2: Ground terminal(G)
Connect to earth ground.
3
2
1
Terminal No. 3: DC output terminals(5V,
+, –)
(
)
Ref.
1
3
5
2
1
G
2
1
Housing
VHR-5N JST
Adapter contact
SVH-21T-P1.1
Connect to load.
L
(
)
L
Terminal No. 4: DC output terminals
(24V, +, –)
N
N
Connect to load.
Terminal No. 5: Not connected(NC)
Do not connect. This should not be
used.
5
Terminal No. 6: Input voltage switching
connector(CP2)
This is used for switching between
input AC voltages.
No CP2 connector: 200V input
CP2 connector in place:100V input
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
ECX-001, -003, -005, -007 Series
Power Supplies
AC Input
Multi Output, General-Purpose
TERMINAL DESIGNATIONS AND FUNCTIONS
ECX-007
Terminal No. 1: AC input terminals(L, N)
1
2
3
4
5
6
7
1
3
5
24V+
24V+
24V–
24V–
5V+
5V–
5V–
G
Connect to AC.100 or 200V single
phase power lines. The product is
shipped set for AC.200V input. If
AC.100V power supply is to be used,
attach the input voltage switching
connector to CP2.
4
3
+
1
(
)
Ref.
24V
5V
4
2
3
4
5
6
7
Housing
VHR-7N JST
Adapter contact
SVH-21T-P1.1
4
3
–
+
–
(
)
Terminal No. 2: Ground terminal(G)
Connect to earth ground.
3
2
1
Terminal No. 3: DC output terminals(5V,
+, –)
1
3
5
1
2
G
L
Connect to load.
(
)
Ref.
2
1
Housing
VHR-5N JST
Adapter contact
SVH-21T-P1.1
Terminal No. 4: DC output terminals
(24V, +, –)
L
(
)
N
Connect to load.
N
CP2
Terminal No. 5: Input voltage switching
connector(CP2)
This is used for switching between
input AC voltages.
5
No CP2 connector: 200V input
CP2 connector in place:100V input
A1551_ECX
980403
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
相关型号:
ECX-1100-GTX1050
ECX-1100, NVIDIA® GeForce® GTX 1050 Ti, 2 GigE LAN, 2 SSD Tray, 6 USB 3.1, 4 COM, 3 SIM, 16 GPIO
VECOW
ECX-1100-GTX1050T
ECX-1100, NVIDIA® GeForce® GTX 1050 Ti, 2 GigE LAN, 2 SSD Tray, 6 USB 3.1, 4 COM, 3 SIM, 16 GPIO
VECOW
ECX-1100GTX1050
ECX-1100, NVIDIA® GeForce® GTX 1050 Ti, 2 GigE LAN, 2 SSD Tray, 6 USB 3.1, 4 COM, 3 SIM, 16 GPIO
VECOW
ECX-1200-GTX1050
ECX-1200, NVIDIA® GeForce® GTX 1050 Ti, 6 GigE LAN w/4 PoE, 2 SSD Tray, 6 USB 3.1, 4 COM, 3 SIM, 32 Isolated DIO
VECOW
ECX-1200-GTX1050T
ECX-1200, NVIDIA® GeForce® GTX 1050 Ti, 6 GigE LAN w/4 PoE, 2 SSD Tray, 6 USB 3.1, 4 COM, 3 SIM, 32 Isolated DIO
VECOW
ECX-1200GTX1050
ECX-1200, NVIDIA® GeForce® GTX 1050 Ti, 6 GigE LAN w/4 PoE, 2 SSD Tray, 6 USB 3.1, 4 COM, 3 SIM, 32 Isolated DIO
VECOW
©2020 ICPDF网 联系我们和版权申明