FCP-031B [TDK]
AC-DC Regulated Power Supply Module, 2 Output, 2.9W, Hybrid, PLASTIC PACKAGE;型号: | FCP-031B |
厂家: | TDK ELECTRONICS |
描述: | AC-DC Regulated Power Supply Module, 2 Output, 2.9W, Hybrid, PLASTIC PACKAGE 输出元件 |
文件: | 总3页 (文件大小:83K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
FCP, FCP-B Series
Power Supplies
AC Input
Multi Output, General-Purpose
FEATURES
• Economical due to small plastic case.
• FCP-B has pin terminals for board mounting.
• These low noise power supplies are FCC class B compliant.
PART NUMBERS AND RATINGS
Output 1(V1)
Voltage(V)
Output 2(V2)
Voltage(V)
Maximum output power
(W)
Part No.
Current(A)
Current(A)
FCP-031
FCP-031B
FCP-032
FCP-032B
FCP-101
FCP-101B
FCP-102
FCP-102B
2.9
3
+12
+15
+12
+15
0.01 to 0.12
–12
–15
–12
–15
0.01 to 0.12
0.01 to 0.1
0.04 to 0.4
0.03 to 0.32
0.01 to 0.1
0.04 to 0.4
0.03 to 0.32
9.6
9.6
TERMINAL DESIGNATIONS AND FUNCTIONS
Terminal No. 1: DC output terminals(V1, 0V, V2)
V.ADJ
+15V
Connect to load.
V1:+output
V1
0V
V2
1
0.32A
POWER SUPPLY
FCP-102
DC OUTPUT
0V:V1, V2 ground
V2:–output
–15V
0.32A
Terminal No. 2: Ground terminal(
For input line.
)
2
3
100-120V
50-60Hz
0.35A
L
Terminal No. 3: AC input terminals(L, N, AC INPUT)
Connect to AC. 100 to 120V single phase power supply.
AC INPUT
N
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
FCP, FCP-B Series
Power Supplies
AC Input
Multi Output, General-Purpose
SPECIFICATIONS
3W TYPE
FCP-031
FCP-031B
+12V • 0.12A
–12V • 0.12A
2.9
FCP-032
Part No.
FCP-032B
+15V • 0.1A
–15V • 0.1A
3
V1
1
Output voltage, current
V2
W
Maximum output power
Input requirements
Input voltage Eac
Input frequency
Input current
Surge current
V
Hz
A
A
mA
%
85 to 132[Rating:100-120]
47 to 66[Single phase][Rating:50-60]
0.08typ.[85V, 25°C, input and output ratings](Output rating:0.1max.)
16max.[25°C, input and output ratings, cold start]
0.5max.[25°C, input and output ratings]
Leakage current
Efficiency
64typ.[25°C, input and output ratings]
Output characteristics
Rated output voltage
Voltage variable range
Maximum output current
Minimum output current
V
V
A
A
V
A
%
%
+12[V1]
–12[V2]
+15[V1]
–15[V2]
10.8 to 13.2[V2 varies simultaneously as V1.]
13.5 to 16.5[V2 varies simultaneously as V1.]
0.1
0.01
15.1
0.1
1
0.12
0.01
12.1
0.12
0.12
0.01
—
0.1
0.01
—
2
Voltage
Current
Output setting con-
ditions
0.12
0.1
Input variation
Load variation
Temperature
variation
0.1typ.[Within the input voltage range]
0.8typ.[10 to 100% load]
Total variation ±3max.(±1typ.)
Voltage stability
%
1typ.[0 to +50°C ]
Drift
%
1max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Dynamic load
%/ms
mV
mV
ms
±4max./1max.[50 to 100% sudden load change]
80
150
100max.
20min.
Ripple Ep-p
Ripple noise Ep-p
Start up time
Hold up time
ms
Accessory equipment
Operation indicator
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Output voltage external variable function
Standards
None
3
Uses overvoltage prevention
Fixed voltage threshold type, automatic recovery.
None
None
None
Safety standards
Noise terminal voltage
Construction
UL478, CSA ELECTRICAL BULLETIN No.1402 approved.
FCC class B compliant.
External dimensions H×W×L
Weight
mm
g
19×55×50[Except input and output terminals]
80max.
Mounting method
Case and cover
Input and output cables
Can be attached to 1side.
Nonflammable resin
—
1 Current rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range.
2 The output load variation is determined within the range set by the minimum output current and the maximum output current. Nominal values might pos-
sibly not be satisfied when output is below the minimum output current.
3 Although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, thereby preventing overvoltage.
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
FCP, FCP-B Series
Power Supplies
AC Input
Multi Output, General-Purpose
SPECIFICATIONS
10W TYPE
FCP-101
FCP-101B
+12V • 0.4A
–12V • 0.4A
9.6
FCP-102
Part No.
FCP-102B
+15V • 0.32A
–15V • 0.32A
9.6
V1
1
Output voltage, current
V2
W
Maximum output power
Input requirements
Input voltage Eac
Input frequency
Input current
Surge current
V
Hz
A
A
mA
%
85 to 132[Rating:100-120]
47 to 66[Single phase][Rating:50-60]
0.25typ.[85V, 25°C, input and output ratings](Output rating :0.1max.)
16max.[25°C, input and output ratings, cold start]
0.5max.[25°C, input and output ratings]
Leakage current
Efficiency
75typ.[25°C, input and output ratings]
Output characteristics
Rated output voltage
Voltage variable range
Maximum output current
Minimum output current
V
V
A
A
V
A
%
%
+12[V1]
–12[V2]
+15[V1]
–15[V2]
10.8 to 13.2[V2 varies simultaneously as V1.]
0.4
0.04
12.1
0.4
13.5 to 16.5[V2 varies simultaneously as V1.]
1
0.4
0.04
—
0.32
0.03
15.1
0.32
0.32
0.03
—
2
Voltage
Current
Output setting con-
ditions
0.4
0.32
Input variation
Load variation
Temperature
variation
0.1typ.[Within the input voltage range]
0.8typ.[10 to 100% load]
Total variation ±3max.(±1typ.)
Voltage stability
%
1typ.[0 to +50°C ]
Drift
%
1max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Dynamic load
%/ms
mV
mV
ms
±4max./1max.[50 to 100% sudden load change]
80
150
100max.
20min.
Ripple Ep-p
Ripple noise Ep-p
Start up time
Hold up time
ms
Accessory equipment
Operation indicator
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Output voltage external variable function
Standards
None
3
Uses overvoltage prevention
Fixed voltage threshold type, automatic recovery.
None
None
None
Safety standards
Noise terminal voltage
Construction
UL478, CSA ELECTRICAL BULLETIN No.1402 approved.
FCC class B compliant.
External dimensions H×W×L
Weight
mm
g
19×55×80[Except input and output terminals]
100max.
Mounting method
Case and cover
Input and output cables
Can be attached to 1side.
Nonflammable resin
—
1 Current rating(maximum output current) is determined for 0 to +50°C. Derating is required when used outside this temperature range.
2 The output load variation is determined within the range set by the minimum output current and the maximum output current. Nominal values might possi-
bly not be satisfied when output is below the minimum output current.
3 Although there is no built-in overvoltage protection circuit, the overvoltage prevention method is used for circuit design, thereby preventing overvoltage.
A152_FCP
980403
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.
相关型号: